tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Civil Works) | 57374273.34 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334270 | 116963 | None | I-1.4.1 P-5 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Footings (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 294.13 | 294.13 | 30.38 | False | None | None | False | None | False | 8935.6694 | 0 | 3334271 | 116963 | None | I-1.5.1 P-6 V-1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 363.4 | 363.4 | 3.38 | False | None | None | False | None | False | 1228.292 | 0 | 3334272 | 116963 | None | I-1.1A P-3 V-3 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 164.08 | 164.08 | 137.13 | False | None | None | False | None | False | 22500.2904 | 0 | 3334273 | 116963 | None | I-4.1 P-5 V-2 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 143.42 | 143.42 | 22.5 | False | None | None | False | None | False | 3226.95 | 0 | 3334274 | 116963 | None | I-1.9 P-7 V-1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 323.3 | 323.3 | 30.38 | False | None | None | False | None | False | 9821.854 | 0 | 3334275 | 116963 | None | I-1.8 P-7 V-1 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 576.1 | 576.1 | 12.5 | False | None | None | False | None | False | 7201.25 | 0 | 3334276 | 116963 | None | I-2.1.3 P-15 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork RCC for Footings (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 7279.03 | 7279.03 | 18.48 | False | None | None | False | None | False | 134516.4744 | 0 | 3334277 | 116963 | None | I-2.2.3 P-15 V-1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork Footings (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 7931.8 | 7931.8 | 10.15 | False | None | None | False | None | False | 80507.77 | 0 | 3334278 | 116963 | None | I-2.2.3 P-15 V-1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork PEDESTALS (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 8470.85 | 8470.85 | 0.86 | False | None | None | False | None | False | 7284.931 | 0 | 3334279 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS, LIFT CORE WALL (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14138.87 | 14138.87 | 5.39 | False | None | None | False | None | False | 76208.5093 | 0 | 3334280 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14280.25 | 14280.25 | 2.86 | False | None | None | False | None | False | 40841.515 | 0 | 3334281 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14421.64 | 14421.64 | 2.86 | False | None | None | False | None | False | 41245.8904 | 0 | 3334282 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14563.04 | 14563.04 | 2.86 | False | None | None | False | None | False | 41650.2944 | 0 | 3334283 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14704.43 | 14704.43 | 50.1 | False | None | None | False | None | False | 736691.943 | 0 | 3334284 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14845.82 | 14845.82 | 40.35 | False | None | None | False | None | False | 599028.837 | 0 | 3334285 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14987.2 | 14987.2 | 18.52 | False | None | None | False | None | False | 277562.944 | 0 | 3334286 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork PLINTH BEAM, RCC SLAB, RCC STAIRCASE GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12475.47 | 12475.47 | 11.39 | False | None | None | False | None | False | 142095.6033 | 0 | 3334287 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12600.23 | 12600.23 | 6.6 | False | None | None | False | None | False | 83161.518 | 0 | 3334288 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12724.98 | 12724.98 | 6.6 | False | None | None | False | None | False | 83984.868 | 0 | 3334289 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12849.74 | 12849.74 | 6.6 | False | None | None | False | None | False | 84808.284 | 0 | 3334290 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12974.49 | 12974.49 | 142.48 | False | None | None | False | None | False | 1848605.3352 | 0 | 3334291 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13099.25 | 13099.25 | 98.63 | False | None | None | False | None | False | 1291979.0275 | 0 | 3334292 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB, RCC STAIRCASE TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13224.0 | 13224.0 | 21.1 | False | None | None | False | None | False | 279026.4 | 0 | 3334293 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13307.17 | 13307.17 | 3.86 | False | None | None | False | None | False | 51365.6762 | 0 | 3334294 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13440.25 | 13440.25 | 3.86 | False | None | None | False | None | False | 51879.365 | 0 | 3334295 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13573.32 | 13573.32 | 3.86 | False | None | None | False | None | False | 52393.0152 | 0 | 3334296 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13706.38 | 13706.38 | 3.86 | False | None | None | False | None | False | 52906.6268 | 0 | 3334297 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13839.45 | 13839.45 | 86.04 | False | None | None | False | None | False | 1190746.278 | 0 | 3334298 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13972.53 | 13972.53 | 61.6 | False | None | None | False | None | False | 860707.848 | 0 | 3334299 | 116963 | None | I-2.5.2 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS, LINTELS TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 14105.6 | 14105.6 | 23.72 | False | None | None | False | None | False | 334584.832 | 0 | 3334300 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 11684.25 | 11684.25 | 0.83 | False | None | None | False | None | False | 9697.9275 | 0 | 3334301 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 11801.09 | 11801.09 | 0.83 | False | None | None | False | None | False | 9794.9047 | 0 | 3334302 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 11917.93 | 11917.93 | 0.83 | False | None | None | False | None | False | 9891.8819 | 0 | 3334303 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12034.77 | 12034.77 | 0.83 | False | None | None | False | None | False | 9988.8591 | 0 | 3334304 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12151.62 | 12151.62 | 17.34 | False | None | None | False | None | False | 210709.0908 | 0 | 3334305 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12268.46 | 12268.46 | 11.07 | False | None | None | False | None | False | 135811.8522 | 0 | 3334306 | 116963 | None | I-2.5.1 P-16 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 12385.3 | 12385.3 | 2.42 | False | None | None | False | None | False | 29972.426 | 0 | 3334307 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 108726.04 | 108726.04 | 4.54 | False | None | None | False | None | False | 493616.2216 | 0 | 3334308 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 109813.3 | 109813.3 | 2.85 | False | None | None | False | None | False | 312967.905 | 0 | 3334309 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 110900.55 | 110900.55 | 2.85 | False | None | None | False | None | False | 316066.5675 | 0 | 3334310 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 111987.82 | 111987.82 | 2.85 | False | None | None | False | None | False | 319165.287 | 0 | 3334311 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 113075.08 | 113075.08 | 42.55 | False | None | None | False | None | False | 4811344.654 | 0 | 3334312 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 114162.35 | 114162.35 | 32.23 | False | None | None | False | None | False | 3679452.5405 | 0 | 3334313 | 116963 | None | I-2.11 a P-18 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Tonne | 115249.6 | 115249.6 | 10.03 | False | None | None | False | None | False | 1155953.488 | 0 | 3334314 | 116963 | None | I-4.21 P-15 S.R 2018-19 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 38.94 | 38.94 | 481.0 | False | None | None | False | None | False | 18730.14 | 0 | 3334315 | 116963 | None | I-6.5 P-13 V-2 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13341.45 | 13341.45 | 19.36 | False | None | None | False | None | False | 258290.472 | 0 | 3334316 | 116963 | None | I-6.5 P-13 V-2 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13474.86 | 13474.86 | 19.36 | False | None | None | False | None | False | 260873.2896 | 0 | 3334317 | 116963 | None | I-6.5 P-13 V-2 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13608.28 | 13608.28 | 19.36 | False | None | None | False | None | False | 263456.3008 | 0 | 3334318 | 116963 | None | I-6.5 P-13 V-2 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 13741.69 | 13741.69 | 19.36 | False | None | None | False | None | False | 266039.1184 | 0 | 3334319 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8184.5 | 8184.5 | 6.0 | False | None | None | False | None | False | 49107.0 | 0 | 3334320 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8266.35 | 8266.35 | 6.0 | False | None | None | False | None | False | 49598.1 | 0 | 3334321 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8348.19 | 8348.19 | 6.0 | False | None | None | False | None | False | 50089.14 | 0 | 3334322 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8430.04 | 8430.04 | 6.0 | False | None | None | False | None | False | 50580.24 | 0 | 3334323 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8511.88 | 8511.88 | 125.25 | False | None | None | False | None | False | 1066112.97 | 0 | 3334324 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8593.73 | 8593.73 | 82.5 | False | None | None | False | None | False | 708982.725 | 0 | 3334325 | 116963 | None | I-12.90 P-110 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 8675.57 | 8675.57 | 21.0 | False | None | None | False | None | False | 182186.97 | 0 | 3334326 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 204.19 | 204.19 | 126.0 | False | None | None | False | None | False | 25727.94 | 0 | 3334327 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 206.23 | 206.23 | 126.0 | False | None | None | False | None | False | 25984.98 | 0 | 3334328 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 208.27 | 208.27 | 126.0 | False | None | None | False | None | False | 26242.02 | 0 | 3334329 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 210.31 | 210.31 | 126.0 | False | None | None | False | None | False | 26499.06 | 0 | 3334330 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 212.35 | 212.35 | 3005.73 | False | None | None | False | None | False | 638266.7655 | 0 | 3334331 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 214.39 | 214.39 | 2028.6 | False | None | None | False | None | False | 434911.554 | 0 | 3334332 | 116963 | None | I-11.34A P-86 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 216.44 | 216.44 | 441.0 | False | None | None | False | None | False | 95450.04 | 0 | 3334333 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 379.2 | 379.2 | 158.44 | False | None | None | False | None | False | 60080.448 | 0 | 3334334 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 382.99 | 382.99 | 158.44 | False | None | None | False | None | False | 60680.9356 | 0 | 3334335 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 386.79 | 386.79 | 158.44 | False | None | None | False | None | False | 61283.0076 | 0 | 3334336 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 390.58 | 390.58 | 158.44 | False | None | None | False | None | False | 61883.4952 | 0 | 3334337 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 394.37 | 394.37 | 2169.51 | False | None | None | False | None | False | 855589.6587 | 0 | 3334338 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 398.17 | 398.17 | 1656.18 | False | None | None | False | None | False | 659441.1906 | 0 | 3334339 | 116963 | None | I-8.4.2 P41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 401.96 | 401.96 | 272.01 | False | None | None | False | None | False | 109337.1396 | 0 | 3334340 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 256.45 | 256.45 | 23.65 | False | None | None | False | None | False | 6065.0425 | 0 | 3334341 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 259.01 | 259.01 | 23.65 | False | None | None | False | None | False | 6125.5865 | 0 | 3334342 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 261.58 | 261.58 | 23.65 | False | None | None | False | None | False | 6186.367 | 0 | 3334343 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 264.14 | 264.14 | 23.65 | False | None | None | False | None | False | 6246.911 | 0 | 3334344 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 266.7 | 266.7 | 1377.23 | False | None | None | False | None | False | 367307.241 | 0 | 3334345 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 269.28 | 269.28 | 947.52 | False | None | None | False | None | False | 255148.1856 | 0 | 3334346 | 116963 | None | I-8.10 P-43 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 271.84 | 271.84 | 476.13 | False | None | None | False | None | False | 129431.1792 | 0 | 3334347 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 121.54 | 121.54 | 182.09 | False | None | None | False | None | False | 22131.2186 | 0 | 3334348 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 122.76 | 122.76 | 182.09 | False | None | None | False | None | False | 22353.3684 | 0 | 3334349 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 123.97 | 123.97 | 182.09 | False | None | None | False | None | False | 22573.6973 | 0 | 3334350 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 125.19 | 125.19 | 182.09 | False | None | None | False | None | False | 22795.8471 | 0 | 3334351 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 126.4 | 126.4 | 3546.74 | False | None | None | False | None | False | 448307.936 | 0 | 3334352 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 127.62 | 127.62 | 2603.7 | False | None | None | False | None | False | 332284.194 | 0 | 3334353 | 116963 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 128.83 | 128.83 | 748.15 | False | None | None | False | None | False | 96384.1645 | 0 | 3334354 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 424.17 | 424.17 | 56.65 | False | None | None | False | None | False | 24029.2305 | 0 | 3334355 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 428.41 | 428.41 | 56.65 | False | None | None | False | None | False | 24269.4265 | 0 | 3334356 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 432.66 | 432.66 | 56.65 | False | None | None | False | None | False | 24510.189 | 0 | 3334357 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 436.9 | 436.9 | 56.65 | False | None | None | False | None | False | 24750.385 | 0 | 3334358 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 441.14 | 441.14 | 568.12 | False | None | None | False | None | False | 250620.4568 | 0 | 3334359 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 445.38 | 445.38 | 390.4 | False | None | None | False | None | False | 173876.352 | 0 | 3334360 | 116963 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 449.63 | 449.63 | 594.52 | False | None | None | False | None | False | 267314.0276 | 0 | 3334361 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 430.25 | 430.25 | 34.96 | False | None | None | False | None | False | 15041.54 | 0 | 3334362 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 434.56 | 434.56 | 34.96 | False | None | None | False | None | False | 15192.2176 | 0 | 3334363 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 438.85 | 438.85 | 34.96 | False | None | None | False | None | False | 15342.196 | 0 | 3334364 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 443.16 | 443.16 | 34.96 | False | None | None | False | None | False | 15492.8736 | 0 | 3334365 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 447.46 | 447.46 | 89.08 | False | None | None | False | None | False | 39859.7368 | 0 | 3334366 | 116963 | None | I-8.3.1 P-41 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 451.76 | 451.76 | 89.08 | False | None | None | False | None | False | 40242.7808 | 0 | 3334367 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 46.19 | 46.19 | 270.3 | False | None | None | False | None | False | 12485.157 | 0 | 3334368 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 46.65 | 46.65 | 270.3 | False | None | None | False | None | False | 12609.495 | 0 | 3334369 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 47.11 | 47.11 | 270.3 | False | None | None | False | None | False | 12733.833 | 0 | 3334370 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 47.57 | 47.57 | 270.3 | False | None | None | False | None | False | 12858.171 | 0 | 3334371 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 48.04 | 48.04 | 3639.3 | False | None | None | False | None | False | 174831.972 | 0 | 3334372 | 116963 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 48.5 | 48.5 | 3639.3 | False | None | None | False | None | False | 176506.05 | 0 | 3334373 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1428.1 | 1428.1 | 3.32 | False | None | None | False | None | False | 4741.292 | 0 | 3334374 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1442.37 | 1442.37 | 3.32 | False | None | None | False | None | False | 4788.6684 | 0 | 3334375 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1456.66 | 1456.66 | 3.32 | False | None | None | False | None | False | 4836.1112 | 0 | 3334376 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1470.94 | 1470.94 | 3.32 | False | None | None | False | None | False | 4883.5208 | 0 | 3334377 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1485.22 | 1485.22 | 806.5 | False | None | None | False | None | False | 1197829.93 | 0 | 3334378 | 116963 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1499.5 | 1499.5 | 550.49 | False | None | None | False | None | False | 825459.755 | 0 | 3334379 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6475.65 | 6475.65 | 51.9 | False | None | None | False | None | False | 336086.235 | 0 | 3334380 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6540.41 | 6540.41 | 37.86 | False | None | None | False | None | False | 247619.9226 | 0 | 3334381 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6605.17 | 6605.17 | 37.86 | False | None | None | False | None | False | 250071.7362 | 0 | 3334382 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6669.93 | 6669.93 | 37.86 | False | None | None | False | None | False | 252523.5498 | 0 | 3334383 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6734.67 | 6734.67 | 104.88 | False | None | None | False | None | False | 706332.1896 | 0 | 3334384 | 116963 | None | I-9.30 P-64 V-2 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6799.43 | 6799.43 | 102.22 | False | None | None | False | None | False | 695037.7346 | 0 | 3334385 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 686.7 | 686.7 | 211.68 | False | None | None | False | None | False | 145360.656 | 0 | 3334386 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 693.57 | 693.57 | 211.68 | False | None | None | False | None | False | 146814.8976 | 0 | 3334387 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 700.44 | 700.44 | 211.68 | False | None | None | False | None | False | 148269.1392 | 0 | 3334388 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 707.3 | 707.3 | 211.68 | False | None | None | False | None | False | 149721.264 | 0 | 3334389 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 714.17 | 714.17 | 396.9 | False | None | None | False | None | False | 283454.073 | 0 | 3334390 | 116963 | None | I-11.28 P-85 V-2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 721.04 | 721.04 | 396.9 | False | None | None | False | None | False | 286180.776 | 0 | 3334391 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 154.36 | 154.36 | 805.19 | False | None | None | False | None | False | 124289.1284 | 0 | 3334392 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 155.9 | 155.9 | 805.19 | False | None | None | False | None | False | 125529.121 | 0 | 3334393 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 157.45 | 157.45 | 805.19 | False | None | None | False | None | False | 126777.1655 | 0 | 3334394 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 158.98 | 158.98 | 805.19 | False | None | None | False | None | False | 128009.1062 | 0 | 3334395 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 160.53 | 160.53 | 3546.74 | False | None | None | False | None | False | 569358.1722 | 0 | 3334396 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 162.07 | 162.07 | 2603.7 | False | None | None | False | None | False | 421981.659 | 0 | 3334397 | 116963 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 163.62 | 163.62 | 748.15 | False | None | None | False | None | False | 122412.303 | 0 | 3334398 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 189.6 | 189.6 | 686.45 | False | None | None | False | None | False | 130150.92 | 0 | 3334399 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 191.5 | 191.5 | 686.45 | False | None | None | False | None | False | 131455.175 | 0 | 3334400 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 193.39 | 193.39 | 686.45 | False | None | None | False | None | False | 132752.5655 | 0 | 3334401 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 195.29 | 195.29 | 686.45 | False | None | None | False | None | False | 134056.8205 | 0 | 3334402 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 197.19 | 197.19 | 568.12 | False | None | None | False | None | False | 112027.5828 | 0 | 3334403 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 197.9 | 197.9 | 390.4 | False | None | None | False | None | False | 77260.16 | 0 | 3334404 | 116963 | None | I-8.32 P-46 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 200.98 | 200.98 | 594.52 | False | None | None | False | None | False | 119486.6296 | 0 | 3334405 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 60.77 | 60.77 | 6.0 | False | None | None | False | None | False | 364.62 | 0 | 3334406 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 61.38 | 61.38 | 6.0 | False | None | None | False | None | False | 368.28 | 0 | 3334407 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 61.99 | 61.99 | 6.0 | False | None | None | False | None | False | 371.94 | 0 | 3334408 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 62.6 | 62.6 | 6.0 | False | None | None | False | None | False | 375.6 | 0 | 3334409 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 63.2 | 63.2 | 143.13 | False | None | None | False | None | False | 9045.816 | 0 | 3334410 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 63.81 | 63.81 | 96.6 | False | None | None | False | None | False | 6164.046 | 0 | 3334411 | 116963 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 64.42 | 64.42 | 32.03 | False | None | None | False | None | False | 2063.3726 | 0 | 3334412 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 139.77 | 139.77 | 6.0 | False | None | None | False | None | False | 838.62 | 0 | 3334413 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 141.16 | 141.16 | 6.0 | False | None | None | False | None | False | 846.96 | 0 | 3334414 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 142.57 | 142.57 | 6.0 | False | None | None | False | None | False | 855.42 | 0 | 3334415 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. THIRD FLOOR (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 143.96 | 143.96 | 6.0 | False | None | None | False | None | False | 863.76 | 0 | 3334416 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 145.36 | 145.36 | 143.13 | False | None | None | False | None | False | 20805.3768 | 0 | 3334417 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 146.76 | 146.76 | 96.6 | False | None | None | False | None | False | 14177.016 | 0 | 3334418 | 116963 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 148.16 | 148.16 | 32.03 | False | None | None | False | None | False | 4745.5648 | 0 | 3334419 | 116963 | None | I-9.136 P-205 CPWD V-2 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 1541.11 | 1541.11 | 105.0 | False | None | None | False | None | False | 161816.55 | 0 | 3334420 | 116963 | None | I-9.137 P-205 CPWD V-1 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). (For Staircase and Lift) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 6790.22 | 6790.22 | 44.1 | False | None | None | False | None | False | 299448.702 | 0 | 3334421 | 116963 | None | I-19.61 P-193 V-2 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 728.07 | 728.07 | 135.25 | False | None | None | False | None | False | 98471.4675 | 0 | 3334422 | 116963 | None | I-2.7B P-8 V-3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead.Cement Concrete Grade M-15 & M-20 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 1179.33 | 1179.33 | 30.7 | False | None | None | False | None | False | 36205.431 | 0 | 3334423 | 116963 | None | I-16.43 P-134 S.R 2018-19 | Dismantling & reconnecting for temprory connectionsof existing plumbing lines ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 116.82 | 116.82 | 240.0 | False | None | None | False | None | False | 28036.8 | 0 | 3334424 | 116963 | None | I-6.32 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1655.86 | 1655.86 | 1473.69 | False | None | None | False | None | False | 2440224.3234 | 0 | 3334425 | 116963 | None | I-6.32 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1671.79 | 1671.79 | 886.19 | False | None | None | False | None | False | 1481523.5801 | 0 | 3334426 | 116963 | None | I-6.32 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1687.71 | 1687.71 | 332.2 | False | None | None | False | None | False | 560657.262 | 0 | 3334427 | 116963 | None | I-6.34 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1395.47 | 1395.47 | 153.11 | False | None | None | False | None | False | 213660.4117 | 0 | 3334428 | 116963 | None | I-6.34 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1408.9 | 1408.9 | 73.65 | False | None | None | False | None | False | 103765.485 | 0 | 3334429 | 116963 | None | I-12.13.1 P-100 V-2 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 124903.74 | 124903.74 | 2.12 | False | None | None | False | None | False | 264795.9288 | 0 | 3334430 | 116963 | None | I-12.13.1 P-100 V-2 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 126104.74 | 126104.74 | 1.3 | False | None | None | False | None | False | 163936.162 | 0 | 3334431 | 116963 | None | I-12.51 P-105 V-2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1284.24 | 1284.24 | 28.0 | False | None | None | False | None | False | 35958.72 | 0 | 3334432 | 116963 | None | I-12.51 P-105 V-2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1296.58 | 1296.58 | 17.0 | False | None | None | False | None | False | 22041.86 | 0 | 3334433 | 116963 | None | I-22.15.2 P-218 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 695.21 | 695.21 | 56.0 | False | None | None | False | None | False | 38931.76 | 0 | 3334434 | 116963 | None | I-22.15.2 P-218 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 701.9 | 701.9 | 34.0 | False | None | None | False | None | False | 23864.6 | 0 | 3334435 | 116963 | None | I-22.15.4 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 474.01 | 474.01 | 28.0 | False | None | None | False | None | False | 13272.28 | 0 | 3334436 | 116963 | None | I-22.15.4 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 478.56 | 478.56 | 17.0 | False | None | None | False | None | False | 8135.52 | 0 | 3334437 | 116963 | None | I-22.15.6 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 189.6 | 189.6 | 56.0 | False | None | None | False | None | False | 10617.6 | 0 | 3334438 | 116963 | None | I-22.15.6 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 191.43 | 191.43 | 34.0 | False | None | None | False | None | False | 6508.62 | 0 | 3334439 | 116963 | None | I-22.15.9 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 88.48 | 88.48 | 88.0 | False | None | None | False | None | False | 7786.24 | 0 | 3334440 | 116963 | None | I-22.15.9 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 89.34 | 89.34 | 55.0 | False | None | None | False | None | False | 4913.7 | 0 | 3334441 | 116963 | None | I-22.15.10 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 126.4 | 126.4 | 28.0 | False | None | None | False | None | False | 3539.2 | 0 | 3334442 | 116963 | None | I-22.15.10 P-219 V-2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 127.62 | 127.62 | 17.0 | False | None | None | False | None | False | 2169.54 | 0 | 3334443 | 116963 | None | I-12.60 P-105 V-2 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1329.74 | 1329.74 | 28.0 | False | None | None | False | None | False | 37232.72 | 0 | 3334444 | 116963 | None | I-12.60 P-105 V-2 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1342.53 | 1342.53 | 17.0 | False | None | None | False | None | False | 22823.01 | 0 | 3334445 | 116963 | None | I-10.6.3 P-69 V-2 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 75.84 | 75.84 | 168.0 | False | None | None | False | None | False | 12741.12 | 0 | 3334446 | 116963 | None | I-10.6.3 P-69 V-2 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 76.57 | 76.57 | 102.0 | False | None | None | False | None | False | 7810.14 | 0 | 3334447 | 116963 | None | I-20.79 P-205 V-2 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 65.73 | 65.73 | 165.0 | False | None | None | False | None | False | 10845.45 | 0 | 3334448 | 116963 | None | I-20.79 P-205 V-2 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 66.36 | 66.36 | 100.65 | False | None | None | False | None | False | 6679.134 | 0 | 3334449 | 116963 | None | I-12.57.6 P-105 V-2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 4199.07 | 4199.07 | 73.44 | False | None | None | False | None | False | 308379.7008 | 0 | 3334450 | 116963 | None | I-12.57.6 P-105 V-2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 4239.43 | 4239.43 | 45.72 | False | None | None | False | None | False | 193826.7396 | 0 | 3334451 | 116963 | None | I-12.85 P-109 V-2 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 7228.9 | 7228.9 | 17.88 | False | None | None | False | None | False | 129252.732 | 0 | 3334452 | 116963 | None | I-12.85 P-109 V-2 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 7298.42 | 7298.42 | 14.1 | False | None | None | False | None | False | 102907.722 | 0 | 3334453 | 116963 | None | I-12.59 P-107 V-2 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1408.12 | 1408.12 | 28.0 | False | None | None | False | None | False | 39427.36 | 0 | 3334454 | 116963 | None | I-12.59 P-107 V-2 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1421.65 | 1421.65 | 17.0 | False | None | None | False | None | False | 24168.05 | 0 | 3334455 | 116963 | None | I-12.93.1 P-111 V-2 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 887.34 | 887.34 | 125.0 | False | None | None | False | None | False | 110917.5 | 0 | 3334456 | 116963 | None | I-12.93.1 P-111 V-2 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 895.87 | 895.87 | 85.0 | False | None | None | False | None | False | 76148.95 | 0 | 3334457 | 116963 | None | I-12.94.1 P-112 V-2 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 4405.09 | 4405.09 | 42.0 | False | None | None | False | None | False | 185013.78 | 0 | 3334458 | 116963 | None | I-12.94.1 P-112 V-2 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 4447.46 | 4447.46 | 28.56 | False | None | None | False | None | False | 127019.4576 | 0 | 3334459 | 116963 | None | I-7.18 P-23 V-2 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 2549.52 | 2549.52 | 99.65 | False | None | None | False | None | False | 254059.668 | 0 | 3334460 | 116963 | None | I-7.18 P-23 V-2 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 2574.04 | 2574.04 | 99.65 | False | None | None | False | None | False | 256503.086 | 0 | 3334461 | 116963 | None | I-15.7 P-150 V-2 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 777.37 | 777.37 | 161.54 | False | None | None | False | None | False | 125576.3498 | 0 | 3334462 | 116963 | None | I-15.7 P-150 V-2 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 784.84 | 784.84 | 96.25 | False | None | None | False | None | False | 75540.85 | 0 | 3334463 | 116963 | None | I-10.5.2 P-69 S.R 2018-19 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 283.2 | 283.2 | 500.0 | False | None | None | False | None | False | 141600.0 | 0 | 3334464 | 116963 | None | I-8.79 P-54 V-2 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 65.73 | 65.73 | 827.2 | False | None | None | False | None | False | 54371.856 | 0 | 3334465 | 116963 | None | I-8.79 P-54 V-2 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 66.36 | 66.36 | 541.2 | False | None | None | False | None | False | 35914.032 | 0 | 3334466 | 116963 | None | I-8.2.1 P-41 V-2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 372.88 | 372.88 | 523.32 | False | None | None | False | None | False | 195135.5616 | 0 | 3334467 | 116963 | None | I-8.2.1 P-41 V-2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 376.47 | 376.47 | 344.43 | False | None | None | False | None | False | 129667.5621 | 0 | 3334468 | 116963 | None | I-9.11 P-60 V-2 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1123.71 | 1123.71 | 103.99 | False | None | None | False | None | False | 116854.6029 | 0 | 3334469 | 116963 | None | I-9.11 P-60 V-2 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1134.51 | 1134.51 | 62.4 | False | None | None | False | None | False | 70793.424 | 0 | 3334470 | 116963 | None | I-9.39 P-65 V-2 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1831.56 | 1831.56 | 418.44 | False | None | None | False | None | False | 766397.9664 | 0 | 3334471 | 116963 | None | I-9.39 P-65 V-2 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1849.17 | 1849.17 | 242.21 | False | None | None | False | None | False | 447887.4657 | 0 | 3334472 | 116963 | None | I-8.34.1 P-47 V-2 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 66.99 | 66.99 | 176.26 | False | None | None | False | None | False | 11807.6574 | 0 | 3334473 | 116963 | None | I-8.34.1 P-47 V-2 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 67.64 | 67.64 | 109.73 | False | None | None | False | None | False | 7422.1372 | 0 | 3334474 | 116963 | None | I-8.82 P-54 V-2 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 855.74 | 855.74 | 176.26 | False | None | None | False | None | False | 150832.7324 | 0 | 3334475 | 116963 | None | I-8.82 P-54 V-2 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 863.97 | 863.97 | 109.73 | False | None | None | False | None | False | 94803.4281 | 0 | 3334476 | 116963 | None | I-18.1 P-181 V-2 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 514.46 | 514.46 | 1121.25 | False | None | None | False | None | False | 576838.275 | 0 | 3334477 | 116963 | None | I-18.1 P-181 V-2 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 519.4 | 519.4 | 672.75 | False | None | None | False | None | False | 349426.35 | 0 | 3334478 | 116963 | None | I-18.3 P-183 V-2 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 3846.4 | 3846.4 | 172.5 | False | None | None | False | None | False | 663504.0 | 0 | 3334479 | 116963 | None | I-18.3 P-183 V-2 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 3883.38 | 3883.38 | 103.5 | False | None | None | False | None | False | 401929.83 | 0 | 3334480 | 116963 | None | I-18.4 P-183 V-2 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5255.78 | 5255.78 | 50.0 | False | None | None | False | None | False | 262789.0 | 0 | 3334481 | 116963 | None | I-18.4 P-183 V-2 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5306.32 | 5306.32 | 30.0 | False | None | None | False | None | False | 159189.6 | 0 | 3334482 | 116963 | None | I-10.15.1 P-71 V-2 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion FOURTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5042.16 | 5042.16 | 69.0 | False | None | None | False | None | False | 347909.04 | 0 | 3334483 | 116963 | None | I-10.15.1 P-71 V-2 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion FIFTH FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5090.64 | 5090.64 | 69.0 | False | None | None | False | None | False | 351254.16 | 0 | 3334484 | 116963 | None | I-11.5.1 P-77 V-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. Terrace Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5769.11 | 5769.11 | 11.03 | False | None | None | False | None | False | 63633.2833 | 0 | 3334485 | 116963 | None | I-15.12 P-152 V-2 | Newly Constructed Roof/Podium with PU Waterproof coating --Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids greater than 85%, Tensile strength greater than 2 Mpa as per ASTM D 412, Elongation at break greater than 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness greater than 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 1500.9 | 1500.9 | 1800.0 | False | None | None | False | None | False | 2701620.0 | 0 | 3334486 | 116963 | None | I-10.1.7 P-113 V-5 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3. TERRACE FLOOR ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Rmtr | 529.5 | 529.5 | 120.0 | False | None | None | False | None | False | 63540.0 | 0 | 3334487 | 116963 | None | I-11.16.2 P-82 V-2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Terrace Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 189.38 | 189.38 | 1650.0 | False | None | None | False | None | False | 312477.0 | 0 | 3334488 | 116963 | None | I-7.34 P-26 V-2 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work. Terrace Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 4026.02 | 4026.02 | 39.0 | False | None | None | False | None | False | 157014.78 | 0 | 3334489 | 116963 | None | I-2.5A P-7 V-3 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle (Concrete Road) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 477.65 | 477.65 | 10.2 | False | None | None | False | None | False | 4872.03 | 0 | 3334490 | 116963 | None | I-1.12 P-8 V-1 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Concrete Road) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 115.46 | 115.46 | 306.0 | False | None | None | False | None | False | 35330.76 | 0 | 3334491 | 116963 | None | I-3.7 P-17 V-3 | Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 127.62 | 127.62 | 1020.0 | False | None | None | False | None | False | 130172.4 | 0 | 3334492 | 116963 | None | I-1.8 P-7 V-1 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 576.1 | 576.1 | 306.0 | False | None | None | False | None | False | 176286.6 | 0 | 3334493 | 116963 | None | I-4.2 V P-23 V-3 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 2867.13 | 2867.13 | 102.0 | False | None | None | False | None | False | 292447.26 | 0 | 3334494 | 116963 | None | I-6.1 P-49 V-3 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 5979.77 | 5979.77 | 76.5 | False | None | None | False | None | False | 457452.405 | 0 | 3334495 | 116963 | None | I-6.2.1 P-49 V-3 | Construction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing. Construction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Cum | 11012.74 | 11012.74 | 102.0 | False | None | None | False | None | False | 1123299.48 | 0 | 3334496 | 116963 | None | I-8.42.2 P-74 V-2 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 303.85 | 303.85 | 566.0 | False | None | None | False | None | False | 171979.1 | 0 | 3334497 | 116963 | None | I-8.10 P-66 V-3 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. (Concrete Road) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 132.48 | 132.48 | 51.0 | False | None | None | False | None | False | 6756.48 | 0 | 3334498 | 116963 | None | I-229 | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and proof checking by IISC/NIT/IIT only as decided by the Department and the same has to be furnished to the Department for approval and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting working drawings, Lift system, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - etc., complete including all lead and lift and work to be executed as per the specification and engineer -in-charge of the work. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | LS | 554000.0 | 554000.0 | 1.0 | False | None | None | False | None | False | 554000.0 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Water Supply & Sanitary Works) | 2320812.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334499 | 116964 | None | I-13.50.5 P-125 V-2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 40mm dia pipes Fourth Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 384.26 | 384.26 | 60.0 | False | None | None | False | None | False | 23055.6 | 0 | 3334500 | 116964 | None | I-13.50.5 P-125 V-2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 40mm dia pipes Fifth Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 387.96 | 387.96 | 60.0 | False | None | None | False | None | False | 23277.6 | 0 | 3334501 | 116964 | None | I-13.50.6 P-125 V-2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes Fourth Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 487.91 | 487.91 | 40.0 | False | None | None | False | None | False | 19516.4 | 0 | 3334502 | 116964 | None | I-13.50.6 P-125 V-2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes Fifth Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 492.6 | 492.6 | 40.0 | False | None | None | False | None | False | 19704.0 | 0 | 3334503 | 116964 | None | I-13.64.1 P-128 V-2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes Fourth Floor ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 365.3 | 365.3 | 130.0 | False | None | None | False | None | False | 47489.0 | 0 | 3334504 | 116964 | None | I-13.64.1 P-128 V-2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 368.81 | 368.81 | 130.0 | False | None | None | False | None | False | 47945.3 | 0 | 3334505 | 116964 | None | I-13.64.2 P-128 V-2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 486.64 | 486.64 | 100.0 | False | None | None | False | None | False | 48664.0 | 0 | 3334506 | 116964 | None | I-13.64.2 P-128 V-2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 491.33 | 491.33 | 100.0 | False | None | None | False | None | False | 49133.0 | 0 | 3334507 | 116964 | None | I-13.63 P-128 V-2 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 308.42 | 308.42 | 32.0 | False | None | None | False | None | False | 9869.44 | 0 | 3334508 | 116964 | None | I-13.63 P-128 V-2 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 311.39 | 311.39 | 32.0 | False | None | None | False | None | False | 9964.48 | 0 | 3334509 | 116964 | None | I-13.47 P-123 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 75mm diameter Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 249.02 | 249.02 | 60.0 | False | None | None | False | None | False | 14941.2 | 0 | 3334510 | 116964 | None | I-13.48 P-123 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 100mm diameter Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 367.83 | 367.83 | 50.0 | False | None | None | False | None | False | 18391.5 | 0 | 3334511 | 116964 | None | I-14.31 P-128 V-2 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete. Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1542.09 | 1542.09 | 5.0 | False | None | None | False | None | False | 7710.45 | 0 | 3334512 | 116964 | None | I-14.31 P-128 V-2 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete. Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1556.93 | 1556.93 | 5.0 | False | None | None | False | None | False | 7784.65 | 0 | 3334513 | 116964 | None | I-13.9.2 P-118 V-2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 352.65 | 352.65 | 7.0 | False | None | None | False | None | False | 2468.55 | 0 | 3334514 | 116964 | None | I-13.9.2 P-118 V-2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 356.05 | 356.05 | 7.0 | False | None | None | False | None | False | 2492.35 | 0 | 3334515 | 116964 | None | I-14.22B P-135 V-2 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic
wall mixer of quality & make as approved by Engineer in charge. Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 7030.45 | 7030.45 | 7.0 | False | None | None | False | None | False | 49213.15 | 0 | 3334516 | 116964 | None | I-14.22B P-135 V-2 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic
wall mixer of quality & make as approved by Engineer in charge. Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 7098.05 | 7098.05 | 7.0 | False | None | None | False | None | False | 49686.35 | 0 | 3334517 | 116964 | None | I-14.40.2 P-137 V-2 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 626.96 | 626.96 | 7.0 | False | None | None | False | None | False | 4388.72 | 0 | 3334518 | 116964 | None | I-14.40.2 P-137 V-2 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 632.98 | 632.98 | 7.0 | False | None | None | False | None | False | 4430.86 | 0 | 3334519 | 116964 | None | I-14.38 P-137 V-2 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm
high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 183.28 | 183.28 | 7.0 | False | None | None | False | None | False | 1282.96 | 0 | 3334520 | 116964 | None | I-14.38 P-137 V-2 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm
high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 185.05 | 185.05 | 7.0 | False | None | None | False | None | False | 1295.35 | 0 | 3334521 | 116964 | None | I-13.16 P-119 V-2 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 783.69 | 783.69 | 20.0 | False | None | None | False | None | False | 15673.8 | 0 | 3334522 | 116964 | None | I-13.16 P-119 V-2 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 FF ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 791.23 | 791.23 | 20.0 | False | None | None | False | None | False | 15824.6 | 0 | 3334523 | 116964 | None | I-14.2.1 P-131 V-2 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required : W.C. pan with ISI marked white solid plastic seat and lid Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6115.31 | 6115.31 | 14.0 | False | None | None | False | None | False | 85614.34 | 0 | 3334524 | 116964 | None | I-14.2.1 P-131 V-2 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required : W.C. pan with ISI marked white solid plastic seat and lid Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6174.11 | 6174.11 | 10.0 | False | None | None | False | None | False | 61741.1 | 0 | 3334525 | 116964 | None | I-14.4.4 P-131 V-2 | Providing and fixing white vitreous china flat back or wall corner type ipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 16520.69 | 16520.69 | 4.0 | False | None | None | False | None | False | 66082.76 | 0 | 3334526 | 116964 | None | I-14.4.4 P-131 V-2 | Providing and fixing white vitreous china flat back or wall corner type ipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 16679.54 | 16679.54 | 4.0 | False | None | None | False | None | False | 66718.16 | 0 | 3334527 | 116964 | None | I-13.15 P-119 V-2 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 916.41 | 916.41 | 20.0 | False | None | None | False | None | False | 18328.2 | 0 | 3334528 | 116964 | None | I-13.15 P-119 V-2 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 925.23 | 925.23 | 20.0 | False | None | None | False | None | False | 18504.6 | 0 | 3334529 | 116964 | None | I-14.7.1 P-132 V-2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3895.7 | 3895.7 | 10.0 | False | None | None | False | None | False | 38957.0 | 0 | 3334530 | 116964 | None | I-14.7.1 P-132 V-2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3933.15 | 3933.15 | 8.0 | False | None | None | False | None | False | 31465.2 | 0 | 3334531 | 116964 | None | I-14.22A P-135 V-2 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1023.85 | 1023.85 | 19.0 | False | None | None | False | None | False | 19453.15 | 0 | 3334532 | 116964 | None | I-14.22A P-135 V-2 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1033.7 | 1033.7 | 17.0 | False | None | None | False | None | False | 17572.9 | 0 | 3334533 | 116964 | None | I-13.8.1.1 P-118 V-2 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 104.91 | 104.91 | 19.0 | False | None | None | False | None | False | 1993.29 | 0 | 3334534 | 116964 | None | I-13.8.1.1 P-118 V-2 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 105.92 | 105.92 | 17.0 | False | None | None | False | None | False | 1800.64 | 0 | 3334535 | 116964 | None | I-14.37.1 P-137 V-2 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 386.79 | 386.79 | 19.0 | False | None | None | False | None | False | 7349.01 | 0 | 3334536 | 116964 | None | I-14.37.1 P-137 V-2 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 390.51 | 390.51 | 17.0 | False | None | None | False | None | False | 6638.67 | 0 | 3334537 | 116964 | None | I-13.28.1 P-137 V-2 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 80.9 | 80.9 | 16.0 | False | None | None | False | None | False | 1294.4 | 0 | 3334538 | 116964 | None | I-13.28.1 P-137 V-2 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 81.68 | 81.68 | 16.0 | False | None | None | False | None | False | 1306.88 | 0 | 3334539 | 116964 | None | I-13.2.1 P-115 V-2 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 361.5 | 361.5 | 25.0 | False | None | None | False | None | False | 9037.5 | 0 | 3334540 | 116964 | None | I-13.2.1 P-115 V-2 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 364.99 | 364.99 | 25.0 | False | None | None | False | None | False | 9124.75 | 0 | 3334541 | 116964 | None | I-9.29 P-63 V-2 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications. Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5442.86 | 5442.86 | 6.0 | False | None | None | False | None | False | 32657.16 | 0 | 3334542 | 116964 | None | I-9.29 P-63 V-2 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications. Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 5495.19 | 5495.19 | 6.0 | False | None | None | False | None | False | 32971.14 | 0 | 3334543 | 116964 | None | I-13.32.1 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 15 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 390.58 | 390.58 | 100.0 | False | None | None | False | None | False | 39058.0 | 0 | 3334544 | 116964 | None | I-13.32.1 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 15 mm nominal dia Pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 394.34 | 394.34 | 100.0 | False | None | None | False | None | False | 39434.0 | 0 | 3334545 | 116964 | None | I-13.32.2 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 20 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 479.06 | 479.06 | 120.0 | False | None | None | False | None | False | 57487.2 | 0 | 3334546 | 116964 | None | I-13.32.2 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 20 mm nominal dia Pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 483.67 | 483.67 | 120.0 | False | None | None | False | None | False | 58040.4 | 0 | 3334547 | 116964 | None | I-13.32.3 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 25 mm nominal dia pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 602.93 | 602.93 | 150.0 | False | None | None | False | None | False | 90439.5 | 0 | 3334548 | 116964 | None | I-13.32.3 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 25 mm nominal dia pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 608.74 | 608.74 | 150.0 | False | None | None | False | None | False | 91311.0 | 0 | 3334549 | 116964 | None | I-13.32.4 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 32 mm nominal dia pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 704.06 | 704.06 | 120.0 | False | None | None | False | None | False | 84487.2 | 0 | 3334550 | 116964 | None | I-13.32.4 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc. 32 mm nominal dia pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 710.83 | 710.83 | 120.0 | False | None | None | False | None | False | 85299.6 | 0 | 3334551 | 116964 | None | I-13.31.5 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 40 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 677.51 | 677.51 | 100.0 | False | None | None | False | None | False | 67751.0 | 0 | 3334552 | 116964 | None | I-13.31.5 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 40 mm nominal dia Pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 683.65 | 683.65 | 100.0 | False | None | None | False | None | False | 68365.0 | 0 | 3334553 | 116964 | None | I-13.31.6 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 987.2 | 987.2 | 80.0 | False | None | None | False | None | False | 78976.0 | 0 | 3334554 | 116964 | None | I-13.31.6 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal dia Pipes Fifth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 996.69 | 996.69 | 80.0 | False | None | None | False | None | False | 79735.2 | 0 | 3334555 | 116964 | None | I-13.33.2 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 274.29 | 274.29 | 100.0 | False | None | None | False | None | False | 27429.0 | 0 | 3334556 | 116964 | None | I-13.33.3 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 374.15 | 374.15 | 50.0 | False | None | None | False | None | False | 18707.5 | 0 | 3334557 | 116964 | None | I-13.33.4 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 470.22 | 470.22 | 30.0 | False | None | None | False | None | False | 14106.6 | 0 | 3334558 | 116964 | None | I-13.4.1 P-117 V-2 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 25 mm nominal bore Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 693.95 | 693.95 | 10.0 | False | None | None | False | None | False | 6939.5 | 0 | 3334559 | 116964 | None | I-13.4.2 P-117 V-2 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm nominal bore Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 755.88 | 755.88 | 10.0 | False | None | None | False | None | False | 7558.8 | 0 | 3334560 | 116964 | None | I-13.4.3 P-117 V-2 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm nominal bore Fourth Floor
---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos. | 887.34 | 887.34 | 10.0 | False | None | None | False | None | False | 8873.4 | 0 | 3334561 | 116964 | None | ELE 7.3.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3
density Rock wool insulation with 22SWG Aluminium cladding 300 L ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 88463.42 | 88463.42 | 2.0 | False | None | None | False | None | False | 176926.84 | 0 | 3334562 | 116964 | None | I-13.34 P-123 V-2 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | l | 11.38 | 11.38 | 5000.0 | False | None | None | False | None | False | 56900.0 | 0 | 3334563 | 116964 | None | Approved Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 154.58 | 154.58 | 30.0 | False | None | None | False | None | False | 4637.4 | 0 | 3334564 | 116964 | None | Approved Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 185.26 | 185.26 | 30.0 | False | None | None | False | None | False | 5557.8 | 0 | 3334565 | 116964 | None | Approved Rate | Air Vent Cowel 75mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 413.0 | 413.0 | 30.0 | False | None | None | False | None | False | 12390.0 | 0 | 3334566 | 116964 | None | Approved Rate | Air Vent Cowel 110mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 590.0 | 590.0 | 30.0 | False | None | None | False | None | False | 17700.0 | 0 | 3334567 | 116964 | None | Data rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 5664.0 | 5664.0 | 8.0 | False | None | None | False | None | False | 45312.0 | 0 | 3334568 | 116964 | None | Data Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 2183.0 | 2183.0 | 25.0 | False | None | None | False | None | False | 54575.0 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Electrical Works) | 3023645.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334569 | 116965 | None | 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Point | 326.94 | 326.94 | 50.0 | False | None | None | False | None | False | 16347.0 | 0 | 3334570 | 116965 | None | 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Point | 460.64 | 460.64 | 110.0 | False | None | None | False | None | False | 50670.4 | 0 | 3334571 | 116965 | None | 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Point | 674.55 | 674.55 | 142.0 | False | None | None | False | None | False | 95786.1 | 0 | 3334572 | 116965 | None | 2.2.4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Point | 822.83 | 822.83 | 20.0 | False | None | None | False | None | False | 16456.6 | 0 | 3334573 | 116965 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Point | 1202.03 | 1202.03 | 10.0 | False | None | None | False | None | False | 12020.3 | 0 | 3334574 | 116965 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 167.73 | 167.73 | 75.0 | False | None | None | False | None | False | 12579.75 | 0 | 3334575 | 116965 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 193.25 | 193.25 | 75.0 | False | None | None | False | None | False | 14493.75 | 0 | 3334576 | 116965 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 215.13 | 215.13 | 50.0 | False | None | None | False | None | False | 10756.5 | 0 | 3334577 | 116965 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 267.39 | 267.39 | 50.0 | False | None | None | False | None | False | 13369.5 | 0 | 3334578 | 116965 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 317.22 | 317.22 | 50.0 | False | None | None | False | None | False | 15861.0 | 0 | 3334579 | 116965 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 387.71 | 387.71 | 15.0 | False | None | None | False | None | False | 5815.65 | 0 | 3334580 | 116965 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 166.51 | 166.51 | 75.0 | False | None | None | False | None | False | 12488.25 | 0 | 3334581 | 116965 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 195.68 | 195.68 | 75.0 | False | None | None | False | None | False | 14676.0 | 0 | 3334582 | 116965 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 212.7 | 212.7 | 50.0 | False | None | None | False | None | False | 10635.0 | 0 | 3334583 | 116965 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 284.4 | 284.4 | 50.0 | False | None | None | False | None | False | 14220.0 | 0 | 3334584 | 116965 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 345.17 | 345.17 | 50.0 | False | None | None | False | None | False | 17258.5 | 0 | 3334585 | 116965 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 418.1 | 418.1 | 15.0 | False | None | None | False | None | False | 6271.5 | 0 | 3334586 | 116965 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 123.97 | 123.97 | 483.0 | False | None | None | False | None | False | 59877.51 | 0 | 3334587 | 116965 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 201.76 | 201.76 | 8.0 | False | None | None | False | None | False | 1614.08 | 0 | 3334588 | 116965 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 207.83 | 207.83 | 160.0 | False | None | None | False | None | False | 33252.8 | 0 | 3334589 | 116965 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 433.9 | 433.9 | 44.0 | False | None | None | False | None | False | 19091.6 | 0 | 3334590 | 116965 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 396.22 | 396.22 | 12.0 | False | None | None | False | None | False | 4754.64 | 0 | 3334591 | 116965 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 286.83 | 286.83 | 12.0 | False | None | None | False | None | False | 3441.96 | 0 | 3334592 | 116965 | None | I-1.13 | Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No | 142.2 | 142.2 | 44.0 | False | None | None | False | None | False | 6256.8 | 0 | 3334593 | 116965 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 80.22 | 80.22 | 2000.0 | False | None | None | False | None | False | 160440.0 | 0 | 3334594 | 116965 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 94.8 | 94.8 | 2500.0 | False | None | None | False | None | False | 237000.0 | 0 | 3334595 | 116965 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 125.19 | 125.19 | 500.0 | False | None | None | False | None | False | 62595.0 | 0 | 3334596 | 116965 | None | 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 82.65 | 82.65 | 1000.0 | False | None | None | False | None | False | 82650.0 | 0 | 3334597 | 116965 | None | 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 96.02 | 96.02 | 1250.0 | False | None | None | False | None | False | 120025.0 | 0 | 3334598 | 116965 | None | 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 120.32 | 120.32 | 250.0 | False | None | None | False | None | False | 30080.0 | 0 | 3334599 | 116965 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 31.6 | 31.6 | 1250.0 | False | None | None | False | None | False | 39500.0 | 0 | 3334600 | 116965 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 51.05 | 51.05 | 3500.0 | False | None | None | False | None | False | 178675.0 | 0 | 3334601 | 116965 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 76.57 | 76.57 | 800.0 | False | None | None | False | None | False | 61256.0 | 0 | 3334602 | 116965 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 111.82 | 111.82 | 1000.0 | False | None | None | False | None | False | 111820.0 | 0 | 3334603 | 116965 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6004.08 | 6004.08 | 4.0 | False | None | None | False | None | False | 24016.32 | 0 | 3334604 | 116965 | None | 5.19.8 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way SP & N ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 2253.35 | 2253.35 | 2.0 | False | None | None | False | None | False | 4506.7 | 0 | 3334605 | 116965 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 504.39 | 504.39 | 71.0 | False | None | None | False | None | False | 35811.69 | 0 | 3334606 | 116965 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3753.16 | 3753.16 | 24.0 | False | None | None | False | None | False | 90075.84 | 0 | 3334607 | 116965 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6255.66 | 6255.66 | 4.0 | False | None | None | False | None | False | 25022.64 | 0 | 3334608 | 116965 | None | 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 5198.27 | 5198.27 | 2.0 | False | None | None | False | None | False | 10396.54 | 0 | 3334609 | 116965 | None | I-32.07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 169607.85 | 169607.85 | 0.1 | False | None | None | False | None | False | 16960.785 | 0 | 3334610 | 116965 | None | I-32.11 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 217523.78 | 217523.78 | 0.1 | False | None | None | False | None | False | 21752.378 | 0 | 3334611 | 116965 | None | I-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 25384.84 | 25384.84 | 0.1 | False | None | None | False | None | False | 2538.484 | 0 | 3334612 | 116965 | None | I-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 37846.34 | 37846.34 | 0.1 | False | None | None | False | None | False | 3784.634 | 0 | 3334613 | 116965 | None | 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 21.88 | 21.88 | 8.0 | False | None | None | False | None | False | 175.04 | 0 | 3334614 | 116965 | None | 6.17.9 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 72.92 | 72.92 | 8.0 | False | None | None | False | None | False | 583.36 | 0 | 3334615 | 116965 | None | 11.3.2 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 838.63 | 838.63 | 220.0 | False | None | None | False | None | False | 184498.6 | 0 | 3334616 | 116965 | None | 11.11.3 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 181.09 | 181.09 | 46.0 | False | None | None | False | None | False | 8330.14 | 0 | 3334617 | 116965 | None | 11.11.5 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 326.94 | 326.94 | 14.0 | False | None | None | False | None | False | 4577.16 | 0 | 3334618 | 116965 | None | I-12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No | 63.2 | 63.2 | 44.0 | False | None | None | False | None | False | 2780.8 | 0 | 3334619 | 116965 | None | I-6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1813.38 | 1813.38 | 14.0 | False | None | None | False | None | False | 25387.32 | 0 | 3334620 | 116965 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3253.63 | 3253.63 | 48.0 | False | None | None | False | None | False | 156174.24 | 0 | 3334621 | 116965 | None | I-12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 76.57 | 76.57 | 104.0 | False | None | None | False | None | False | 7963.28 | 0 | 3334622 | 116965 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 148.28 | 148.28 | 220.0 | False | None | None | False | None | False | 32621.6 | 0 | 3334623 | 116965 | None | I-13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 382.85 | 382.85 | 48.0 | False | None | None | False | None | False | 18376.8 | 0 | 3334624 | 116965 | None | I-13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 859.29 | 859.29 | 14.0 | False | None | None | False | None | False | 12030.06 | 0 | 3334625 | 116965 | None | 5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sq CM | 0.52 | 0.52 | 376000.0 | False | None | None | False | None | False | 195520.0 | 0 | 3334626 | 116965 | None | 5.40.2 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 4174.9 | 4174.9 | 5.0 | False | None | None | False | None | False | 20874.5 | 0 | 3334627 | 116965 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 370.7 | 370.7 | 10.0 | False | None | None | False | None | False | 3707.0 | 0 | 3334628 | 116965 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 918.84 | 918.84 | 10.0 | False | None | None | False | None | False | 9188.4 | 0 | 3334629 | 116965 | None | 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 10315.1 | 10315.1 | 3.0 | False | None | None | False | None | False | 30945.3 | 0 | 3334630 | 116965 | None | 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 160Amps 25kA ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 16343.48 | 16343.48 | 1.0 | False | None | None | False | None | False | 16343.48 | 0 | 3334631 | 116965 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 898.18 | 898.18 | 2.0 | False | None | None | False | None | False | 1796.36 | 0 | 3334632 | 116965 | None | I-5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 11321.45 | 11321.45 | 1.0 | False | None | None | False | None | False | 11321.45 | 0 | 3334633 | 116965 | None | I-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 625.93 | 625.93 | 3.0 | False | None | None | False | None | False | 1877.79 | 0 | 3334634 | 116965 | None | I-5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 683.05 | 683.05 | 3.0 | False | None | None | False | None | False | 2049.15 | 0 | 3334635 | 116965 | None | 7.3.3 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with
100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 300 Liter capacity ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 85060.98 | 85060.98 | 4.0 | False | None | None | False | None | False | 340243.92 | 0 | 3334636 | 116965 | None | 7.1.3 | Supplying and fixing of 25litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 12448.13 | 12448.13 | 12.0 | False | None | None | False | None | False | 149377.56 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Lift System) | 2705406.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334637 | 116966 | None | 14.4.5 | Design, supplying, erecting testing and commissioning of - 15Passenger/ Bed-cum-passenger hospital lift(7 stops/7 Opening) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. Without Machine Room - SS finish capacity. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 2705406.97 | 2705406.97 | 1.0 | False | None | None | False | None | False | 2705406.97 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (D.G Set) | 722100.89 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334638 | 116967 | None | 10.1.2 | Supplying, installing, testing and commissioning of 20KVA/16kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with echanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Set | 480200.89 | 480200.89 | 1.0 | False | None | None | False | None | False | 480200.89 | 0 | 3334639 | 116967 | None | A.R | PLC Control:-Supply, Erection, testing and commissioning of Automatic load load sharing with ,MDM with suitable CT's,Hardware interlocking through Aux contactor with timers , UV and OV, Annunciator, Programmable logic controller 24IP and 24OP,Battery charger,Relay board,AC and DC indicating lamp, along with control wiring. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 | 3334640 | 116967 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 5900.0 | 5900.0 | 5.0 | False | None | None | False | None | False | 29500.0 | 0 | 3334641 | 116967 | None | A.R | Supply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 236.0 | 236.0 | 300.0 | False | None | None | False | None | False | 70800.0 | 0 | 3334642 | 116967 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Mtr | 236.0 | 236.0 | 100.0 | False | None | None | False | None | False | 23600.0 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Furniture Works) | 3514075.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334643 | 116968 | None | A.R | Providing and fixing of CLASS ROOM CHAIRS etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No. | 3304.0 | 3304.0 | 58.0 | False | None | None | False | None | False | 191632.0 | 0 | 3334644 | 116968 | None | A.R | Single Cot ( Size : 1950 x 900 x 450 ) Structure made of 100 x 50mm & 50 x 50mm well seasoned Hard wood with provision of back rest in 18mm thick fully marine grade plywood as per drawings. Hard wood structure polish, with necessary staining, sanding and finishing with Coir and Foam Matters 5" Complete with all materials, labour, leads lifts etc and directed by Engineer in charge ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No. | 10620.0 | 10620.0 | 59.0 | False | None | None | False | None | False | 626580.0 | 0 | 3334645 | 116968 | None | A.R | Providing & fixing of Study table of size 900mm(W) X 600mm(D) X 750mm(H). The legs of the table should be made out of teak wood of size 50mm x 50mm reapers and the frames of the table (both top and bottom) of size 75mmx 35mm. Table top should be covered with 19mm thick plywood with alround necessary teak wood beading with 1mm thick laminated with single drawer and finished with melamine spray polish with necessary fixtures and fittings etc., including all lead, lift, scaffolding and any other incidental charges. Complete as per specification, drawing and direction of the Engineer in charge of the work. Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No. | 8850.0 | 8850.0 | 57.0 | False | None | None | False | None | False | 504450.0 | 0 | 3334646 | 116968 | None | A.R | DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. (GROUND FLOOR) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No | 35046.0 | 35046.0 | 2.0 | False | None | None | False | None | False | 70092.0 | 0 | 3334647 | 116968 | None | A.R | Manufacturing, supplying and fixing wooden ward robe of 0.60m deep
using 19mm thick vinyl bonded water proof block board, with mirror on one side door and shutters allround ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support finished in approved 1mm lamination sheet of approved colour, shade and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specification. Type : Loose Furniture Specifications : Top - Made of 25mm thick E1 grade pre-laminated particle board . & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sqm | 13924.0 | 13924.0 | 152.35 | False | None | None | False | None | False | 2121321.4 | 0 |
| 1719208981000 | 0 | None | None | Buildings | CONSTRUCTION OF 4th & 5th FLOOR OVER EXISTING C & D HOSTEL BLOCK IN THE PRIMISES OF HIMS AT HASSAN, HASSAN DISTRICT. (Fire Fighting Works) | 4730676.07 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3334648 | 116969 | None | I-15.77 P-86 V-6 PWDEle S.R 2023-24 | Supply, installation, testing and commissioning electrically driven Terrance
pump of capacity 900.0 Lpm at 35.0m Head bronze impeller pump coupled to
electrical driven motor with suitable HP with all the necessary accessories,
operating on 3Ph 50Hz, 400/440V AC supply including required foundation
for pump, anti vibration pad, founadtion bolts etc. complete. Including
cost of materials, labour, usage charges of machinery complete as per
specifications and control panel is not included. Required GA drawingfor the
pump/ foundation shall be submitted by the contractor. (BOOSTER PUMP) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No. | 109386.0 | 109386.0 | 2.0 | False | None | None | False | None | False | 218772.0 | 0 | 3334649 | 116969 | None | I-15.152 P-99 V-6 PWDEle S.R 2023-24 | Supplying Installing testing and commission of Electrical Booster pump
Control panel for fire fighting system consisting of Feeder For 1 No. of
Booster pumps :-1 no of 32 A TPN MCCB (50 KA with 12.5 HP DOL
starter with over load relay, single phase preventer ON / OFF push buttons. 1
No. Auto manual selector switch. 1 set of RYB indicating lamps with
individual HRC Control Fuses 1 set of RYB indicating lamps with individual
HRC Control Fuses 1 no 16 sq.mm 0-800Amps. Ammeter with selector
switch and Suitable rated current transformers 1 No.0-800 96 sq. mm
Voltmeter and selector Switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 42539.0 | 42539.0 | 2.0 | False | None | None | False | None | False | 85078.0 | 0 | 3334650 | 116969 | None | I-15.127.2 P-94 V-6 PWDEle S.R 2023-24 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves
of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc.,
complete as per specificaiton with all lead and lift, loading unloading, labour,
hire charges of machineries and all such incidental charges necessary for
successful completion of work and as per directions of the Engineer-in charge of the work. 150mm dia CI butterfly valves ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Set | 15192.5 | 15192.5 | 2.0 | False | None | None | False | None | False | 30385.0 | 0 | 3334651 | 116969 | None | I-15.127.3 P-94 V-6 PWDEle S.R 2023-24 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves
of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc.,
complete as per specificaiton with all lead and lift, loading unloading, labour,
hire charges of machineries and all such incidental charges necessary for
successful completion of work and as per directions of the Engineer-in charge of the work. 100mm dia CI butterfly valves ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Set | 10938.6 | 10938.6 | 6.0 | False | None | None | False | None | False | 65631.6 | 0 | 3334652 | 116969 | None | I-15.128.3 P-95 V-6 PWDEle S.R 2023-24 | Supplying installing, testing and commissioning of PN16 CI "Non Return
Valve " confirming to IS 13039 with necessary bolts and nuts etc complete
includes cost of all materials labour charges with all lead lift loading and
unloading transportation etc complete. ---- etc., complete as per specificaiton
with all lead and lift, loading unloading, labour, hire charges of machineries
and all such incidental charges necessary for successful completion of work
and as per directions of the Engineer-in-charge of the work 100 mm Dia CI Non Return Valve ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Set | 8653.65 | 8653.65 | 2.0 | False | None | None | False | None | False | 17307.3 | 0 | 3334653 | 116969 | None | I-15.129.3 P-95 V-6 PWDEle S.R 2023-24 | supply and installing testing and commissioning of CI " Y " stainer
confirming to IS standard with necessary bolts and nuts complete includes
cost of all materials labour charges with all lead lift loading and unloading
transportation etc complete. ---- etc., complete as per specificaiton with all
lead and lift, loading unloading, labour, hire charges of machineries and all
such incidental charges necessary for successful completion of work and as
per directions of the Engineer-in-charge of the work 100 mm Dia CI " Y " stainer. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 15058.81 | 15058.81 | 2.0 | False | None | None | False | None | False | 30117.62 | 0 | 3334654 | 116969 | None | I-15.132 P-96 V-6 PWDEle S.R 2023-24 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon
Tube including with all accssories as per IS:Spec. etc., complete as per
specificaiton with all lead and lift, loading unloading, labour, hire charges of
machineries and all such incidental charges necessary for successful
completion of work and as per directions of the Engineer-in-charge of the
work ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3524.66 | 3524.66 | 2.0 | False | None | None | False | None | False | 7049.32 | 0 | 3334655 | 116969 | None | I-15.131 P-95 V-6 PWDEle S.R 2023-24 | Pressure Switch including Isolation Valve and forged siphon Tube including
with all accssories as per IS:Spec. ---- etc., complete as per specificaiton with
all lead and lift, loading unloading, labour, hire charges of machineries and
all such incidental charges necessary for successful completion of work and
as per directions of the Engineer-in-charge of the work ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 2370.03 | 2370.03 | 2.0 | False | None | None | False | None | False | 4740.06 | 0 | 3334656 | 116969 | None | I-11.16.2 P-82 V-2 PWD S.R 2023-24 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Kg | 178.66 | 178.66 | 1000.0 | False | None | None | False | None | False | 178660.0 | 0 | 3334657 | 116969 | None | I-32.14 P-13 PWDELe S.R 2023-24 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100
V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs
and Glands etc completed. 3.5 Core 95.00 Sq.mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 453605.51 | 453605.51 | 0.1 | False | None | None | False | None | False | 45360.551 | 0 | 3334658 | 116969 | None | I-32.05 P-13 PWDEle S.R 2023-24 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100
V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs
and Glands etc completed.4.0 Core 16.00 Sq.mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Km | 172394.77 | 172394.77 | 0.2 | False | None | None | False | None | False | 34478.954 | 0 | 3334659 | 116969 | None | I-1.17.3 P-3 CPWD SR 21-22 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100
V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs
and Glands etc completed.3 Core x 1.5Sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 115.46 | 115.46 | 100.0 | False | None | None | False | None | False | 11546.0 | 0 | 3334660 | 116969 | None | I-4.1.4 P-18 CPWD SR 21-22 | Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. 300 mm width x 50mm depth x 2.0mm thickness ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 944.37 | 944.37 | 100.0 | False | None | None | False | None | False | 94437.0 | 0 | 3334661 | 116969 | None | I-12.58.2 P-54 V-6 PWDEle S.R 2023-24 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. (25 x 3 mm GI strip) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 99.66 | 99.66 | 40.0 | False | None | None | False | None | False | 3986.4 | 0 | 3334662 | 116969 | None | I-15.86 P-89 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1823.1 | 1823.1 | 14.0 | False | None | None | False | None | False | 25523.4 | 0 | 3334663 | 116969 | None | I-15.125 P-94 V-6 PWDEle S.R 2023-24 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1458.48 | 1458.48 | 14.0 | False | None | None | False | None | False | 20418.72 | 0 | 3334664 | 116969 | None | I-15.118.3 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 150 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 4740.06 | 4740.06 | 20.0 | False | None | None | False | None | False | 94801.2 | 0 | 3334665 | 116969 | None | I-15.118.4 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 100 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 3463.89 | 3463.89 | 200.0 | False | None | None | False | None | False | 692778.0 | 0 | 3334666 | 116969 | None | I-15.118.5 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 80 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 2795.42 | 2795.42 | 60.0 | False | None | None | False | None | False | 167725.2 | 0 | 3334667 | 116969 | None | I-15.118.6 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 65 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 2066.18 | 2066.18 | 50.0 | False | None | None | False | None | False | 103309.0 | 0 | 3334668 | 116969 | None | I-15.118.7 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications.50 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 1580.02 | 1580.02 | 100.0 | False | None | None | False | None | False | 158002.0 | 0 | 3334669 | 116969 | None | I-15.118.8 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 40 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 1276.17 | 1276.17 | 40.0 | False | None | None | False | None | False | 51046.8 | 0 | 3334670 | 116969 | None | I-15.118.9 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications. 32 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 972.32 | 972.32 | 50.0 | False | None | None | False | None | False | 48616.0 | 0 | 3334671 | 116969 | None | I-15.118.10 P-93 V-6 PWDEle S.R 2023-24 | Supply, Installation testing and commissioning of approved make heavy tubes
(Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm
thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,
40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore
4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90
Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal
bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @
21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc.
including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech
pipe/M.S.angle supports work includes two coats of metal primer and two
coats of Red enamel paint etc. including cost of materials, labour, usage
charges of machinery complete as per specifications.25 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 850.78 | 850.78 | 100.0 | False | None | None | False | None | False | 85078.0 | 0 | 3334672 | 116969 | None | I-15.98.2 P-91 V-6 PWDEle S.R 2023-24 | Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. including
cost of materials, labour, usage charges of machinery complete as per
specifications 150 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Mtr | 486.16 | 486.16 | 4.0 | False | None | None | False | None | False | 1944.64 | 0 | 3334673 | 116969 | None | I-18.23.2 CPWD 21-22 | Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 10964.12 | 10964.12 | 4.0 | False | None | None | False | None | False | 43856.48 | 0 | 3334674 | 116969 | None | I-15.124 P-94 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire
brigade inlet connection of 2 nos. 63 mm dia. including cost of materials,
labour, usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No | 40108.2 | 40108.2 | 1.0 | False | None | None | False | None | False | 40108.2 | 0 | 3334675 | 116969 | None | I-15.86 P-89 V-6 PWDEle S.R 2023-24 | FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | No | 12761.7 | 12761.7 | 14.0 | False | None | None | False | None | False | 178663.8 | 0 | 3334676 | 116969 | None | I-15.88 P-89 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6077.0 | 6077.0 | 28.0 | False | None | None | False | None | False | 170156.0 | 0 | 3334677 | 116969 | None | I-15.87 P-89 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 5469.3 | 5469.3 | 14.0 | False | None | None | False | None | False | 76570.2 | 0 | 3334678 | 116969 | None | A.R | Fire duct Shutter fabricated out of MS sheet & frame of 16 SWG CRCA with 2 doors & 4 mm thick glazed glass with water proof beading. Door shall be of size 900mm x 1200mm min. with suitable rubber beeding & locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside with white and red out side. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 7670.0 | 7670.0 | 14.0 | False | None | None | False | None | False | 107380.0 | 0 | 3334679 | 116969 | None | I-15.91 P-89 V-6 PWDEle S.R 2023-24 | Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180degree swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6320.08 | 6320.08 | 14.0 | False | None | None | False | None | False | 88481.12 | 0 | 3334680 | 116969 | None | I-15.92 P-90 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 7292.4 | 7292.4 | 14.0 | False | None | None | False | None | False | 102093.6 | 0 | 3334681 | 116969 | None | I-13.37 P-123 V-2 PWD S.R 2023-24 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 1458.48 | 1458.48 | 28.0 | False | None | None | False | None | False | 40837.44 | 0 | 3334682 | 116969 | None | I-15.93 P-90 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57degreeCOrange, 68degreeC - Red, 79degreeC - Yellow, 93degreeC - Green, 141degreeC - Blue, 182degreeC Mauve, 227/260degreeC - Black) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 455.78 | 455.78 | 125.0 | False | None | None | False | None | False | 56972.5 | 0 | 3334683 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Elbow 25/15 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 212.4 | 212.4 | 10.0 | False | None | None | False | None | False | 2124.0 | 0 | 3334684 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Elbow 25/25 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 212.4 | 212.4 | 20.0 | False | None | None | False | None | False | 4248.0 | 0 | 3334685 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 25/15/25 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 295.0 | 295.0 | 10.0 | False | None | None | False | None | False | 2950.0 | 0 | 3334686 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 25/25/25 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 295.0 | 295.0 | 10.0 | False | None | None | False | None | False | 2950.0 | 0 | 3334687 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 32/15/32 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 413.0 | 413.0 | 10.0 | False | None | None | False | None | False | 4130.0 | 0 | 3334688 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 32/25/32 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 365.8 | 365.8 | 10.0 | False | None | None | False | None | False | 3658.0 | 0 | 3334689 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 40/15/40 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 531.0 | 531.0 | 10.0 | False | None | None | False | None | False | 5310.0 | 0 | 3334690 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Tee 40/25/40 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 531.0 | 531.0 | 10.0 | False | None | None | False | None | False | 5310.0 | 0 | 3334691 | 116969 | None | A.R | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Forged Collar 25/15 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 129.8 | 129.8 | 10.0 | False | None | None | False | None | False | 1298.0 | 0 | 3334692 | 116969 | None | I-15.33 P-72 V-6 PWDEle S.R 2023-24 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6684.7 | 6684.7 | 6.0 | False | None | None | False | None | False | 40108.2 | 0 | 3334693 | 116969 | None | I-15.4 P-62 V-6 PWDEle S.R 2023-24 | Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3463.89 | 3463.89 | 10.0 | False | None | None | False | None | False | 34638.9 | 0 | 3334694 | 116969 | None | I-15.34 P-72 V-6 PWDEle S.R 2023-24 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 7900.1 | 7900.1 | 14.0 | False | None | None | False | None | False | 110601.4 | 0 | 3334695 | 116969 | None | I-15.112 P-93 V-6 PWDEle S.R 2023-24 | Supplying of two bucket stand alongwith buckets. complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1336.94 | 1336.94 | 10.0 | False | None | None | False | None | False | 13369.4 | 0 | 3334696 | 116969 | None | I-15.72 P-14 PWD S.R 21-22 | Providing and fxing in position the following type of sign boards made out of
3mm thick "Opaque" PVC foam board with computer cut, PVC non-refective self adhesive vinyl
painted foam board, complete with mirror fasteners. Providing's Escape Singage
Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV
resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and
lead free. Available in different types & sizes, Time after removing the light source (in minutes)
60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/
sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In
Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per
specifcations.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS
INSTRUCTED OTHERWISE" Size:-25cm x 30 cm) (Floor identifcation signage ( ie, GROUND
FLOOR …etc.) at each stair enclosure on every foor, indicating the foor number in words,
lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x
60cm.) (signage with text FIRE EXIT, size shall be 15cm x 60cm)(route plan Fire Escape Route
Plan A2 Size) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Sq CM | 2.43 | 2.43 | 105400.0 | False | None | None | False | None | False | 256122.0 | 0 | 3334697 | 116969 | None | I-15.106 P-92 V-6 PWDEle S.R 2021-22 | Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'. A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3038.5 | 3038.5 | 14.0 | False | None | None | False | None | False | 42539.0 | 0 | 3334698 | 116969 | None | I-15.106 P-92 PWD S.R 21-22 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor) C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY: PHONE : (Current phone numbers to be provided in this location by the contractor) FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3038.5 | 3038.5 | 14.0 | False | None | None | False | None | False | 42539.0 | 0 | 3334699 | 116969 | None | I-15.108.3 P-92 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 98447.4 | 98447.4 | 1.0 | False | None | None | False | None | False | 98447.4 | 0 | 3334700 | 116969 | None | I-15.109 P-93 V-6 PWDEle S.R 2023-24 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Nos | 42842.85 | 42842.85 | 1.0 | False | None | None | False | None | False | 42842.85 | 0 | 3334701 | 116969 | None | I-15.110 P-93 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of MIKE suitable to
I.A.System. Complete ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 6684.7 | 6684.7 | 1.0 | False | None | None | False | None | False | 6684.7 | 0 | 3334702 | 116969 | None | I-15.107 P-92 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of Public address system
(Two way comminication type) as per requirement of Fire Force authority
and which Generally comprise of Supplying Installing, testing and
commissioning of Approved make 6 W.wall mounted speaker with talk back
facility with store enamel painted M.S.Sheet hosing etc. complete including
cost of materials, labour, usage charges of machinery complete as per
specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 2977.73 | 2977.73 | 14.0 | False | None | None | False | None | False | 41688.22 | 0 | 3334703 | 116969 | None | I-15.105 P-92 V-6 PWDEle S.R 2023-24 | Supplying and drawing of 2 Core X 1.5 Sqmm copper conductor armoured
cable ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | m | 182.31 | 182.31 | 2150.0 | False | None | None | False | None | False | 391966.5 | 0 | 3334704 | 116969 | None | I-15.66.2 P-84 V-6 PWDEle S.R 2023-24 | Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. 4 Loop Panel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 303850.0 | 303850.0 | 1.0 | False | None | None | False | None | False | 303850.0 | 0 | 3334705 | 116969 | None | I-15.102 P-96 V-6 PWDEle S.R 2023-24 | Supplying Installing, testing and commissioning of electronic Hooter, it
conists of electronic circuit to give dual Fire alaram sound with works. 24V
DC with speaker all encased in suitable in MS 16 gauge red painted box.
complete including cost of materials, labour, usage charges of machinery
complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 1823.1 | 1823.1 | 14.0 | False | None | None | False | None | False | 25523.4 | 0 | 3334706 | 116969 | None | I-15.73 P-85 V-6 PWDEle S.R 2023-24 | Supply, install, test and commissioning of Analogue addressable Manual Call
Point (Resettable Type) with inbuilt isolator and LED indicator, designed
for IP44 requirements and approved to operate in minus10degreeC to +55degreeC
temperature, complies with the essential requirement of the EMC Directive
to be supplied with Barriers, Junction Box, Glands and other mounting
accessories for proper installation. (For Detectors/Device without inbuilt
isolator, Fault Isolator or Isolator base to be provided with each
detector/device) Approval VDS. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3646.2 | 3646.2 | 14.0 | False | None | None | False | None | False | 51046.8 | 0 | 3334707 | 116969 | None | I-1.4.2 P-2 PWDEle S.R 2023-24 | Supplying and fixing sheet Metal box made out of 18 SWG
sheet metal with necessary holes for cable/conduit entry as
required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 143.42 | 143.42 | 15.0 | False | None | None | False | None | False | 2151.3 | 0 | 3334708 | 116969 | None | I-15.72 P-14 PWD S.R 2023-24 | Supply, install, test and commissioning of Analogue addressable Monitor Cum
Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED
indicator, approved to operate in minus10degreeC to +55degreeC temperature, complies with the
essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 4740.06 | 4740.06 | 1.0 | False | None | None | False | None | False | 4740.06 | 0 | 3334709 | 116969 | None | I-9.5.1 P-38 V-6 PWDEle S.R 2023-24 | Supplying, installation, testing & commissioning of 12V DC, AH
batteries in poly propylene container for U.P.S. Sealed maintenance
free batteries. 7 AH capacity ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge. | Each | 3963.42 | 3963.42 | 2.0 | False | None | None | False | None | False | 7926.84 | 0 |
|
|
---|