tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719304221000 | 0 | None | None | Buildings | Auditorium | 6186033.51 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345536 | 117573 | None | Vol-I I No. 2.5.1 page No. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 10.06 | False | None | None | False | None | False | 70732.9666 | 0 | 3345537 | 117573 | None | Vol-I S R S L No. 9 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 Percent | Cum | 4921.78 | 4921.78 | 10.06 | False | None | None | False | None | False | 49513.1068 | 0 | 3345538 | 117573 | None | Vol-I S R Sl no. 2.5.1 Page no. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 36.42 | False | None | None | False | None | False | 256073.0262 | 0 | 3345539 | 117573 | None | Vol-I S R Sl No. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60 Percent | Cum | 4218.67 | 4218.67 | 36.42 | False | None | None | False | None | False | 153643.9614 | 0 | 3345540 | 117573 | None | Vol-I I No. 2.5.1 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 79.31 | False | None | None | False | None | False | 557637.3341 | 0 | 3345541 | 117573 | None | Vol-I S R Sl No. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50 Percent | Cum | 7031.11 | 7031.11 | 79.31 | False | None | None | False | None | False | 557637.3341 | 0 | 3345542 | 117573 | None | Vol-I S R I No. 2.5.1 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 5.4 | False | None | None | False | None | False | 37967.994 | 0 | 3345543 | 117573 | None | Vol-I S R S L No. 19 Page No. 19 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of
minor sections add 45 Percent | Cum | 3164.0 | 3164.0 | 5.4 | False | None | None | False | None | False | 17085.6 | 0 | 3345544 | 117573 | None | Vol-I S R I No. 6.8 Page No. 14 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8451.12 | 8451.12 | 75.3 | False | None | None | False | None | False | 636369.336 | 0 | 3345545 | 117573 | None | Vol-I I No. 6.15 Page No. 14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery
& other incidental charges complete as per the direction of engineer
incharge of work. | Sqm | 1095.5 | 1095.5 | 30.33 | False | None | None | False | None | False | 33226.515 | 0 | 3345546 | 117573 | None | Vol-I I No. 2.1.4 Page no. 15 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6593.13 | 6593.13 | 1.0 | False | None | None | False | None | False | 6593.13 | 0 | 3345547 | 117573 | None | 2018-19 S R I No. 15.35 | KSRB 15.8.2: Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, JUnction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment)KSRB 15.8.2- do- suitable plaster mesh 150mm wide | Rmtr | 31.31 | 31.31 | 395.4 | False | None | None | False | None | False | 12379.974 | 0 | 3345548 | 117573 | None | Vol-II INo. 8.1.1 Page No. 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 270.43 | 270.43 | 1063.56 | False | None | None | False | None | False | 287618.5308 | 0 | 3345549 | 117573 | None | Vol-II I No. 8.5.2 page no. 42 | Providing 15 mm cement plaster on rough side of single or half brick
wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 370.11 | 370.11 | 27.0 | False | None | None | False | None | False | 9992.97 | 0 | 3345550 | 117573 | None | Vol-II I No. 8.8 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 393.44 | 393.44 | 324.0 | False | None | None | False | None | False | 127474.56 | 0 | 3345551 | 117573 | None | Vol-II I No. 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 1063.56 | False | None | None | False | None | False | 112790.538 | 0 | 3345552 | 117573 | None | Vol-II I No. 8.25 Page No. 45 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 145.29 | 145.29 | 1063.56 | False | None | None | False | None | False | 154524.6324 | 0 | 3345553 | 117573 | None | Vol-II I No. 8.29 Page No. 45 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 L/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 300.12 | 300.12 | 324.0 | False | None | None | False | None | False | 97238.88 | 0 | 3345554 | 117573 | None | Vol-II I No. 12.11 Page no. 99 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 146427.48 | 146427.48 | 0.3 | False | None | None | False | None | False | 43928.244 | 0 | 3345555 | 117573 | None | Vol-II I No. 12.57.1 Page No. 105 | Providing and fixing flush door shutter made out of solid core block board
type, well seasoned , chemicaly treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame alround door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door useing liquid phenol formaldehyde
resin as per IS specifications 2202 (part-I) 1991. from manufacturer
complete as per spcification. 30 mm thick Both side teak | Sqm | 4287.6 | 4287.6 | 9.25 | False | None | None | False | None | False | 39660.3 | 0 | 3345556 | 117573 | None | Vol-II I No. 12.84 Page No. 108 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi
chambered UPVC(Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and
lead free, gaskets -grey color having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 44mm width x 40mmheight with reinforcement
of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing
bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall
be provided with 5mm plain float glass, standard hardware& single point
locking system with Crescent Locks. Wall thickness of frame & sash shall be
of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive
of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5326.89 | 5326.89 | 72.0 | False | None | None | False | None | False | 383536.08 | 0 | 3345557 | 117573 | None | Vol-II I No. 11.34A Page No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 178.16 | 178.16 | 1719.9 | False | None | None | False | None | False | 306417.384 | 0 | 3345558 | 117573 | None | Vol-II I No. 8.34.3 Page No. 48 | Applying priming coat: With ready mixed red oxide zinc chromate
primer of approved brand and manufacture on steel galvanised iron/
steel works including preparing the surface after thorougly cleaning oil,
grease, dirt and foreign matter, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 53.02 | 53.02 | 81.9 | False | None | None | False | None | False | 4342.338 | 0 | 3345559 | 117573 | None | Vol-II I No. 8.64 Page No. 51 | Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade :One coats on old
work as per specifications and as per directions of Engineer in charge. | Sqm | 80.6 | 80.6 | 81.9 | False | None | None | False | None | False | 6601.14 | 0 | 3345560 | 117573 | None | Vol-II I No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1077.47 | 1077.47 | 3.0 | False | None | None | False | None | False | 3232.41 | 0 | 3345561 | 117573 | None | Vol-II S R Sl no. 444 Page No. A-25 | Hold fasts | No | 52.5 | 52.5 | 9.0 | False | None | None | False | None | False | 472.5 | 0 | 3345562 | 117573 | None | Vol-II I no. 8.34.2 Page No. 47 | Applying priming coat: With ready mixed aluminium primer of approved
brand and manufacture on resinous wood and plywood including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 61.51 | 61.51 | 22.18 | False | None | None | False | None | False | 1364.2918 | 0 | 3345563 | 117573 | None | 2018-19 S R 15.16.1 | KSRB 15-17.7: Providing and applying painting one coat (excluding priming coat ) on new wood surface and I or wood based surface with enamel paint to give an even shade after cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. | Sqm | 62.62 | 62.62 | 22.18 | False | None | None | False | None | False | 1388.9116 | 0 | 3345564 | 117573 | None | Vol-II I no. 9.12.2 Page No. 60 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 497.21 | False | None | None | False | None | False | 603747.1867 | 0 | 3345565 | 117573 | None | Vol-II I no. 10.18 Page No. 71 | Providing and fixing of wall cladding using 20mm thick gang saw water
cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand)
proportion cut to required shape, pattern with paper joints, finished with
cement mortal using white cement and colour pigments to match the colour
of slab making through jointing with sealant, making holes 25mmx12mm
grooves in joints including cost of all materials, mortar, labour, curing etc.,
complete. | Sqm | 3562.22 | 3562.22 | 46.67 | False | None | None | False | None | False | 166248.8074 | 0 | 3345566 | 117573 | None | Vol-I I no. 2.11 a Page no. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. Buildings | t | 94869.15 | 94869.15 | 10.34 | False | None | None | False | None | False | 980947.011 | 0 | 3345567 | 117573 | None | Vol-II I No. 15.7 Page No. 150 | Providing and supplying crystalline integral concrete waterproofing
admixture that waterproofs concrete by forming crystals deep in the
pores, capillaries and microcracks of the concrete, self-seal waterproofing
compound to bridge shrinkage cracks upto 0.5mm in width & resist
hydro-static pressure upto 16bar for both positive & negative pressure
confirming to DIN 1048 part 5 for 56% reduction in depth of penetration
against control, resistance to chloride penetration confirming to ASTM
C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious
content in concrete. ie., integral crystaline waterproofing admix @ 0.5
kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20
grade of Concrete is considered in the analysis) | Sqm | 652.21 | 652.21 | 499.42 | False | None | None | False | None | False | 325726.7182 | 0 | 3345568 | 117573 | None | Vol-I I No. 2.1.3 Page No. 15 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6351.33 | 6351.33 | 22.03 | False | None | None | False | None | False | 139919.7999 | 0 |
| 1719304221000 | 0 | None | None | Buildings | material supply | 9108324.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345569 | 117574 | None | As per Gem Portal Product id: 5116877-64673724233 | Providing supplying Fixing and Installation of THREE SEATER Class Room Desking / Seating INTEGRATED DESK CUM SEATING WITH SHELF / STORAGE UNDER DESK Having the Following Specification :: Material of Desk Top +/- 2 mm (For shelf / storage +/- 4 mm) 18 mm thick prelaminated Particle Board Material of Support Structure or Side Pannel Mild Steel square Section of size 25x25 mm and wall thickness minimum 1.6 mm Height of Desk Top in mm (5 mm) 750 Width of Desk Top in mm (5 mm) 450 TYPE OF DESKING INTEGRATED DESK CUM SEATING WITH SHELF / STORAGE UNDER DESK Desking Configuration THREE SEATER Length of Desking, Seating and Backrest (if provided) in mm (10 mm) 1500 Material of Seat and Backrest (if provided) (+/- 2 mm (For back rest +/- 4 mm) 18 mm thick prelaminated Particle Board Material of Support Structure Mild Steel Square Section of outside side minimum 25 mm and wall thickness minimum 1.2 mm Material of Seat Cushion WITHOUT CUSHION Width of Seating in mm (10 mm) 300 Height of Seat in mm (10 mm) 460 Width of backrest if provided in mm ( 5 mm) 200 Back Support for Seating of Same materail as Seating Provided with Cushion Warranty eriod in number of years 2 | Each | 18500.0 | 18500.0 | 189.0 | False | None | None | False | None | False | 3496500.0 | 0 | 3345570 | 117574 | None | As per Gem Portal Product id: 5116877-52834879352 | Providing supplying Fixing and Installation of FLOYD Almirah Steel shelving cabinets Having the Following Specification :Technical specification of Almirah steel Generally conforming to BIS specification IS: 3312:2021 (with latest amendment) :Type of Almirah steel Almirah Steel shelving cabinets Number of door 2,Number of shelves 4 Colour of finish Ash Grey Steel sheet material Mild steel sheets conforming to grade HR1 of IS 1079:2009 (with latest amendment) ,Almirah height(excluding the height of pedestal) 5 mm 1830 mm,Almirah width 5 mm 920 mm, Almirah depth 5 mm 480 mm,Side sheet thickness 0.9 mm, Back sheet thickness 0.9 mm,Top sheet thickness 0.9 mm,Bottom sheet thickness 1 mm,Shelves sheet thickness 0.9 mm, Hinges sheet thickness 1.25 mm(double folded),Handle size 12 cm,Steel Almirah lock/locker lock Six lever lock,Material of lock Brass and Steel finish,Finish coat with enamels Conforming to IS : 2932 (Part 1),Powder coating With 50 micron thickness minimum | Each | 22800.0 | 22800.0 | 15.0 | False | None | None | False | None | False | 342000.0 | 0 | 3345571 | 117574 | None | As per Gem Portal Product id: 5116877-58911626958 | Providing supplying Fixing and Installation of DHIMAN INTERIORS Rectangular Cross type Classroom Tables Having the Following Specification :Technical Mode of supply Assembled ready to use,Shape of the table Rectangular,Style of table Supported by set of Legs,Design of table With four legs only,Loading capacity of table top in KG ( 5 Kg) 100 kg,Foot Rest Provided YES,Table Top Material Prelaminated Particle Board,All side Beeding on edges of table top 2.0 mm thick PVC tape with the help of hot melt glue,Shoes Material Plastic,Padestal (Under structure) MS square pipe of 25 mm with wall thickness of 1.02 mm (18 gauge),Foot Rest Material MS square pipe of 25 mm with wall thickness of 1.02 mm (18 gauge),Frame material MS square pipe of size 25 mm with wall thickness of 1.02 mm (18 gauge),Leg material MS square pipe of 25 mm with wall thickness of 1.02 mm (18 gauge),Table Top Length 10(mm) 700 mm,Table Top Width 10(mm) 470 mm,Table Height 10(mm) 750 mm,Table top thickness 18 mm,WARRANTY PERIOD 1-year | Each | 8000.0 | 8000.0 | 10.0 | False | None | None | False | None | False | 80000.0 | 0 | 3345572 | 117574 | None | As per Gem Portal Product id: 5116877-80800543313 | Providing supplying Fixing and Installation of FURNILO Almirah Steel with Glass door Having the Following Specification :Technical specification of Almirah steel Generally conforming to BIS specification IS: 3312:2021 (with latest amendment),Type of Almirah steel Almirah Steel with Glass door,Construction type Welded,Installation Free standing,Pedestal Yes,Pedestal fitted with 3 mm Teflon Bush,Pedestal height ( 5 mm) 125 mm,Door type Hinged,Number of door 2,Number of hinges (for each door) 3,Uniformly distributed load (UDL) for shelves 60 Kgs.,Steel sheet material Mild steel sheets conforming to grade HR1 of IS 1079:2009 (with latest amendment),Sheet rounds and flats Conforming to grade E250 of IS 2062,Stiffener material MS sheet,Almirah height(excluding the height of pedestal) 5 mm 1980 mm,Almirah width 5 mm 910 mm,Almirah depth 5 mm 480 mm,Side sheet thickness 0.8 mm,Back sheet thickness 0.8 mm,Top sheet thickness 0.8 mm,Bottom sheet thickness 0.8 mm,Hinges sheet thickness 1.25 mm(double folded),Steel Almirah lock/locker lock Six lever lock,Steel Almirah locking mechanism A three way bolting device controlled by a lock, | Each | 48000.0 | 48000.0 | 10.0 | False | None | None | False | None | False | 480000.0 | 0 | 3345573 | 117574 | None | As per Gem Portal Product id: 5116877-74796182568 | Providing supplying Fixing and Installation of Stein World 900 mm wide 1830 mm high Metal Shelving Racks Stein World R Having the Following Specification :Type OPEN TYPE Pigeon Holes without,Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted) 4,Shelves Material 0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,M S Sheet Thickness of Shelves and Back (Minimum) in mm 0.8,Sides, Back and Partition Wall Thickness (Minimum) (mm) MS Sheet 0.8 mm,Angle Posts Material and size Rolled steel angle posts of 40 X 40 X 2 mm,Depth in mm (5 mm) 400,Width in mm (5 mm) 900,Height in mm (5 mm) 1830,Bin Strip Height in mm (1 mm) 25,Warranty in number of years 1, | Each | 15600.0 | 15600.0 | 10.0 | False | None | None | False | None | False | 156000.0 | 0 | 3345574 | 117574 | None | As per Gem Portal Product id: 5116877-77352660322 | Providing supplying Fixing and Installation of V J Interior TWO SEATER Class Room Desking / Seating ONLY TABLE / DESK Having the Following Specification :Material of Desk Top +/- 2 mm (For shelf / storage +/- 4 mm) 18 mm thick prelaminated Particle Board,Material of Support Structure or Side Pannel Mild Steel Pipe of diameter 25 mm and wall thickness 1.1 mm minimum,Height of Desk Top in mm (5 mm) 750,Width of Desk Top in mm ( 5 mm) 400,TYPE OF DESKING ONLY TABLE / DESK,Desking Configuration TWO SEATER,Length of Desking, Seating and Backrest (if provided) in mm (10 mm) 850,Material of Seat and Backrest (if provided) (+/- 2 mm (For back rest +/- 4 mm) ONLY DESK NO SEATING,DESIGN AS PER DGS&D drawing No DQA/GE/RC-208/Schedule 19 (DRG 1,2,3,4,5,6,7,8,9,10) Can be configured as per buyer's choice within offered technical details,Colour of finish As per buyer's choice,Warranty period in number of years 1 | Each | 8600.0 | 8600.0 | 10.0 | False | None | None | False | None | False | 86000.0 | 0 | 3345575 | 117574 | None | As per Gem Portal Product id: 5116877-22195700723 | Providing supplying Fixing and Installation of Unbranded Non-Revolving and Non-Tilting chair with Armrest Having the Following Specification :Chair Type Non-Revolving and Non-Tilting chair with Armrest,Chair frame type Cantilever,Armrest type Moulded armrest continuously fitted with seat bottom to backrest,Armrest front side Curved,Shoe/Studs material PVC,Seat Fitted Over flat size in depth-wise of the frame on both sides with minimum 3 screws,Backrest Fitted By round head screws 3 Nos. (minimum) on each side,Armrest Fitted With round steel screws 3 Nos. (minimum) on each side,rame material Steel tube (ERW quality) conforming to IS: 1161 (with latest Amendment),Section Size (Diameter/Sides) of frame 25 mm,The armrest material Wood fixed on Frame material,Seat material Polyethylene cane Confmg. to IS 5378-1994 (with latest amendment) with wooden frame,eat material thickness 1.6 mm,Backrest material Polythene cane Confmg. to IS 5378-1994 (with latest amendment) with wooden frame,Seat Depth (5 mm) 430 mm,eat Width ( 5 mm) 440 mm,Seat height from floor surface ( 5 mm) 435 mm,Backrest width ( 5 mm) 450 mm,Backrest height from seat ( 5 mm) 320 mm,Arm Length ( 5 mm) 300 mm,Arm Width ( 2 mm) 40 mm | Each | 1750.0 | 1750.0 | 40.0 | False | None | None | False | None | False | 70000.0 | 0 | 3345576 | 117574 | None | As per Gem Portal :Product id: 5116877-64844506340 | Providing supplying Fixing and Installation of ASHIRWAD Mild Steel Pipe of diameter 25 mm and wall thickness 1.1 mm minimum Classroom Chairs, Warranty 2 Years Having the Following Specification :Chair Type One Arm with fixed Writing pad on one side other side open,Type of Seat and Backrest Made of Wood,Depth of Seat in mm (+/- 10 mm) 300,Height of Seat in mm (+/- 10 mm) 400,Width of Seat in mm (+/- 10 mm) 300,Overall Chair Height in mm (+/- 10 mm) 700,Thickness of Cushion Used in Seat in mm (+/- 2 mm) 40,Density of Cushion Used in Seat (Kg/Cubic Metre) 40,Material of Fabric of Seat Cover 290 GSM cloth fabric,Density of Cusion Used in Backrest (Kg/Cubic Metre) 40,hickness of Cushion in Backrest in mm (+/- 2 mm) 40,Material of Fabric of Backrest Cover 290 gSM Cloth Fabric,Frame Material Mild Steel Pipe of diameter 25 mm and wall thickness 1.1 mm minimum | Each | 10000.0 | 10000.0 | 50.0 | False | None | None | False | None | False | 500000.0 | 0 | 3345577 | 117574 | None | As per Gem Portal Product id: 5116877-53152729102 | Providing supplying Fixing and Installation of MERAKI FURNITURE PRIVATE LIMITED Wooden Podium design Gable end and modesty panel and top material Commercial Block Board MR Grade Conforming to IS 1659 Having the Following Specification :Mode of supply Assembled Ready To Use,Frame type Free standing,Understructure of podium Gable end and modesty panel,Storage Closed storage,Shelves 1 - shelve,Paper stop Yes,Podium top Material Commercial Block Board MR Grade Conforming to IS 1659,Podium top long sides To be post form half round profile with corner edge bending,Podium top plain sides CP Teak Wood Lipping,Gable end and modesty panel plain side CP Teak Wood Lipping,Number of buffers provided 4 Nos. at bottom,Thickness of podium top 2mm 19 millimeter,Thickness of gable end and modesty panel 2mm 19 millimeter,Length of podium top 10mm 600 millimeter,Depth of podium 10mm 500 millimetern,Height of podium 10mm 1250 millimeter,Presenter side height 10mm 1100mm,Width of shelves 10mm 600mm,Depth of shelves in mm (10mm) 400mm,Podium top finish Laminate in colour with swede finish 0.6-0.8mm thickness of type S,F or P having index no.3.2.3 conforming to IS 2046/Latest with having balancing laminate of 0.5mm thick on other side | Each | 18000.0 | 18000.0 | 5.0 | False | None | None | False | None | False | 90000.0 | 0 | 3345578 | 117574 | None | As per Gem Portal Product id: 5116877-92996025516 | Providing supplying Fixing and Installation of ALKOSIGN Writing Board Having the Following Specification ;Top Surface materials (Used for white board surface) Melamine,Top surface material thickness 0.7 mm to 0.8 mm,Frame material Anodized extruded aluminum alloy hollow section designation 63400 conforming to IS 1285 (With latest amendment),Frame wall thickness 1.2 mm,Frame section front 20 mm,Frame section side 16 mm,Core material MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness 9 mm,Core material bulk density 750 kg per cubic meter,Backing material thickness 0.25 mm,Dimension (mm x mm) 1200 x 2400,Vitreous enamel coating thickness on the top 0.11 mm,Vitreous enamel coating thickness on the back (Minimum) 0.03 mm,Product wrapped in Moisture resistant sheets,Packed in Corrugated box, | Each | 19500.0 | 19500.0 | 10.0 | False | None | None | False | None | False | 195000.0 | 0 | 3345579 | 117574 | None | As per Gem Portal Product id: 5116877-36475932849 | Providing supplying Fixing and Installation of OPENLX Library Management Software In premises Deployment Having the Following Specification;Name of Software KOHA LMS,Type of Licensing Subscription,Name of the OEM BEST BOOK BUDDIES,OEM Model / Part No CLIENT-SERVER,Software Description LMS,Software Version 20.11.X,Date of Launch of Version NOV 2020,Capability to access digital content Yes,Capability to integrate with third party applications Yes,nbuilt collaboration capability Yes,Barcoding / RFID Yes,Digital libraries Management capability Yes,Deployment options In premises,Number of Years upto which Support is available from OEM / Franchise online 5,Z39 50 support Yes,Automated cloud backup Yes,Code thirty-nine barcode support Yes,Mobile platform support Yes,Acquisition Management Yes,Barcode Scanning Yes,Domain Catalog Management Yes,Circulation Management Yes,Fee Collection Yes,Online Public Access Catalog (OPAC) Yes,Dynamic Location Tagging Yes,Integration with Barcode Printer Yes,Integration with Data Capturing unit Yes,Integration with biometric Yes,Report Generation Yes,Role based access Yes,Department library lending Yes,upported Library Protocols ALL STANDARD,Hard Disk Space Required ABOVE 100GB,RAM Size required 16 GB,Server requirements INTEL XEON,.CPU required INTEL XEON OR ABOVE,Other Hardware requirements SAN - OPTIONAL,Operating Systems supported (Driver) LINUX,Supported Devices ALL,Supported databases MySql MariaDB,Free updates and upgrades within support period Yes | Each | 100000.0 | 100000.0 | 2.0 | False | None | None | False | None | False | 200000.0 | 0 | 3345580 | 117574 | None | As per Gem Portal Product id: 5116877-57633804182 | Providing supplying Fixing and Installation of KYOCERa Laser Mono Computer Printers for A4 paper size Having the Following Specification;Cartridge Technology separate toner and drum,Printing Technology Laser,Type of Printing Mono,Paper Size A4,Resolution (Dpi) 1200x1200,Processor Speed 800 MHz,Memory (MB) 512,Duplexing Feature Yes,Network Interface, if available Ethernet 10/100/1000,If Yes, Type of Wireless Connectivity Wireless (802.11 b/g/n),Each Main Paper Tray Capacity 250,Bypass Tray Facility Yes,If Yes, Bypass Tray Capacity 100,ield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC: 19752/2004(E) for Black (Number of prints) 3500,BIS Registration no R-41002970,Dimensions(In mm x mm x mm ) 475X412X437 | Each | 67800.0 | 67800.0 | 1.0 | False | None | None | False | None | False | 67800.0 | 0 | 3345581 | 117574 | None | As per Gem Portal Product id: 5116877-52131175467 | Providing supplying Fixing and Installation of NEUNAX inkjet Color Computer Printers for A4 paper size Having the Following Specification Cartridge Technology Ink,Printing Technology inkjet,Type of Printing Colour,Paper Size A4,Print Speed per minute as per ISO/IEC 24734 in (A4) Size-Mono 10,Print Speed per minute as per ISO IEC 24734 in (A4)-Color 7,Resolution (Dpi) 600x600,Memory (MB) 2,Each Main Paper Tray Capacity 150,Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC 19798/2007(E) for Cyan colour (Number of prints) 690,Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC: 19798/2007(E) for Yellow colour (Number of prints) 690,Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC19798/2007(E) for Magenta colour (Number of prints) 690,Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC: 19752/2004(E) for Black (Number of prints) 1500,Dimensions(In mm x mm x mm ) 42.6 x 25.5 x 13.1 | Each | 20689.0 | 20689.0 | 1.0 | False | None | None | False | None | False | 20689.0 | 0 | 3345582 | 117574 | None | As per Gem Portal Product id: 5116877-6484817122 | Providing supplying Fixing and Installation of EPSON inkjet Mono Computer Printers for A4 paper size Having the Following Specification;Cartridge Technology Ink,Printing Technology inkjet,Type of Printing Mono,Dimensions(In mm x mm x mm ) 435 x 268 x 148 mm,BIS Registration no R-41000914,Duty Cycle (No of Prints/month) 5000,Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC: 19752/2004(E) for Black (Number of prints) 6000,If Yes, Type of Wireless Connectivity Wireless(802.11 b/g/n) | Each | 14204.0 | 14204.0 | 1.0 | False | None | None | False | None | False | 14204.0 | 0 | 3345583 | 117574 | None | As per Gem Portal Product id: 5116877-15262084644 | Providing supplying Fixing and Installation of ALKOSIGN Portrait/ Landscape Acrylic (minimum 2 mm thickness) Fabric Pin Up Notice Boards Having the Following Specification;Width of Board in mm 900 mm,Colour(Front/ Display layer) Green,Height of Board in mm 1800mm,Front cover material of Board Acrylic (minimum 2 mm thickness),Rear panel material of Board Galvanised iron sheet,Front layer thickness of Board (front) in mm 1 millimeter,Overall pinability depth of Board in mm 15 millimeter,Frame material of Board Aluminium,Core material thickness in mm(N = 9) 9 millimeter, Core layer material of Board SOFT BOARD, Orientation Portrait/ Landscape, Name of Test lab National Woollen and Furnishers | Each | 9645.0 | 9645.0 | 2.0 | False | None | None | False | None | False | 19290.0 | 0 | 3345584 | 117574 | None | As per Gem Portal Product id: 5116877-42434436827 | Providing supplying Fixing and Installation of Dell Intel Core i5 10500 4 GB/ 1000 GB HDD/ Windows 10 Professional Chipset Series Intel Q Series,Chipset Number Intel Q 470,Expansion Slots (PCIe x 1) (Number) 1,Expansion Slots (PCIe x 16) (Number) 1,Expansion Slots (M Dot 2) 2,Processor Make Intel,Processor Generation 10,Number of Cores per Processor 6,Processor Base Frequency (GHz) 3.1,Processor Description Intel Core i5,Processor Number Intel Core i5 10500,Graphics Type Integrated,Graphic Card Description intel integrated,Operating System (Factory Pre-Loaded) Windows 10 Professional,Recovery Image Media Stored in Partition of the Hard Disk,OS Certification Windows,Type of RAM DDR4,RAM Size (GB) 4,RAM Speed (MHz) 2666,Total Numbers of DIMM Slots Available 2,Number of DIMM Slots populated 1,RAM Expandability up to( using spare DIMM Slots in GB) 64,apacity of each HDD (GB) 1000 @7200 rpm,Cabinet Form Factor SFF ( 7 to 13 Litres),ype of Ethernet Ports 10/100/1000 on board Integrated Gigabit Port,Model of the Monitor E2222H,LED Backlit Monitor Size (INCHES) 21.5,Monitor Resolution (PIXELS) 1920x1080,On Site OEM Warranty (Year) 3 | Each | 107675.0 | 107675.0 | 25.0 | False | None | None | False | None | False | 2691875.0 | 0 | 3345585 | 117574 | None | As per Gem Portal Product id: 5116877-88891658496 | Providing supplying Fixing and Installation of SANITARY PAD DISPOSAL MACHINE Having the Following Specification: Type of machine Automatic,Type of fitting Wall Mountable,Color Blue,Napkin Size for loading Any size,.Napkin Fold Without fold,Operating features Free vending,Number of Napkins/pads provided/loaded with the vending machine -10,ending option Horizontal,Accessibility for free vending utility service Biometrics,Type of loading Spiral less,Maximum Storage Capacity (Nos)(Nos) 75-100,Material of the outer body Mild Steel(MS),All MS parts are duly painted by Powder coating,Input Power supply 220v +/- 10%, 50Hz, Single Phase AC,Width (mm) 100-200,Depth (mm) 50-100,Height (mm) 200-500,Weight (kg) 10-20,Thickness of SS/MS sheet (mm) 0.9,Thickness of FRP/Plastic sheet (mm) 1-2,Submission of Test Report on form 39 or form Central Govt/NABL/ILAC accredited Lab or Manufacture's inhouse Test Report to prove the conformity to declared specification at the time of supply Yes | Each | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 | 3345586 | 117574 | None | It. No. 9.2.5 Pg. No. 29 of 47 | Supplying erecting, testing OFF-LINE UPS system - UNI SR 2022-23 Chapter-9 It. No. 9.2.5 Pg. No. 29 of 47 a. 5 KVA off Line UPS | No | 38661.0 | 38661.0 | 2.0 | False | None | None | False | None | False | 77322.0 | 0 | 3345587 | 117574 | None | It. No. 9.4.5 Pg. No. 29 of 47 | Supply, Installation, testing 12V All Batteries - UWI SR 2022-23 Chapter-9 It. No. 9.4.5 Pg. No. 29 of 47 a. 120 AH capacity | No | 22135.0 | 22135.0 | 3.0 | False | None | None | False | None | False | 66405.0 | 0 | 3345588 | 117574 | None | As per Gem Portal Product id: 5116877-55143067252 | Providing supplying Fixing and Installation of Chest Press Having the Following Specification: Type Chest Press Double,Length 1000 millimeter,Width 650 millimeter,vWidth 650 millimeter,Maximum User Weight ( Kg ) 100 kilogram,Governing Specification for GI Pipes BIS specification No IS 1239 ( Part 1 )- 2004, latest,All the GI Pipes are ISI marked Yes,Main Central Pipe 80mm Nominal Bore G.I. Pipe,Main Central Pipe, Class as per IS 1239 Medium,Designation of Main Central Pipe ( as per IS 1161 ) HEAVY,Handle Frame 32mm Nominal bore G.I. pipe,Handle Frame Pipe, Class as per IS 1239 Medium,Designation of Handle Frame Pipe ( as per IS 1161 ) HEAVY,Seat Frame 32mm Nominal Bore G.I. Pipe,Seat Frame Pipe, Class as per IS 1239 Medium,Designation of Seat Frame Pipe ( as per IS 1161 ) HEAVY,.Connecting Links 32mm Nominal Bore G.I. Pipe,Connecting Links Pipe, Class as per IS 1239 Medium,Designation of connecting link Pipe ( as per IS 1161 ) HEAVY,Foot Rest Pipe 25mm Nominal Bore G.I. Pipe,Foundation Pipes with anchoring 750mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm,nstruction Plate Stainless Steel, Size 150 X 230 X 0.7mm, with indelible printing,Warranty ( years ) 2 year | Each | 48000.0 | 48000.0 | 1.0 | False | None | None | False | None | False | 48000.0 | 0 | 3345589 | 117574 | None | As per Gem Portal :Product id:5116877-51697184344 | Providing supplying Fixing and Installation of Type Leg Press Double Having the Following Specification: Type Leg Press DoubleLength 2000 millimeter,Width 800 millimeter,Height 2200 millimeter,Maximum User Weight ( Kg ) 120 kilogram,Governing Specification for GI Pipes BIS specification No IS 1239 ( Part 1 )- 2004, latest,ll the GI Pipes are ISI marked Yes,Main Central Pipe 100mm Nominal Bore G.I. Pipe,Main Central Pipe, Class as per IS 1239 Heavy,Moving Frame Pipe 32mm Nominal bore G.I. pipe,Foot Rest Frame/ Foot Rest Hinging Pipe 25mm Nominal Bore G.I. Pipe,Foot Rest Frame Pipe, Class as per IS 1239 Heavy,Connecting Links 32mm Nominal Bore G.I. Pipe,MS Foundation Plate Thickness 10 millimeter,Foundation Pipes with anchoring 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm,Galvanization of all Pipes Zinc coating on the tubes shall be in accordance with IS 4736 latest.,Seat and Back Rest 2mm Thick G.I. Seat with uniform bending radius to avoid sharp edges,ll Plastic Components U V stabilised, weather resistance,Ergonomic Design Yes,Instruction Plate Stainless Steel, Size 150 X 230 X 0.7mm, with indelible printing,Registration No and Validity of Registration 13ZAB02603Q,Warranty ( years ) 2 year | Each | 50000.0 | 50000.0 | 2.0 | False | None | None | False | None | False | 100000.0 | 0 | 3345590 | 117574 | None | As per Gem Portal Product id: 5116877-69655417469 | Providing supplying Fixing and Installation of Replay Triple Twister ( Three standing ) Twister - Outdoor Gym Equipment Having the Following Specification: Type Triple Twister ( Three standing ),Length 1500 millimeter,Width 800 millimeter,Height 1400 millimeter,Maximum User Weight ( Kg ) 110 kilogram,Governing Specification for GI Pipes BIS specification No IS 1161:2014, latest,All the GI Pipes are ISI marked Yes,Main Central Pipe 100mm Nominal Bore G.I. Pipe,Main Frame Pipe, Class as per IS 1239 Heavy,Main Central Pipe ( As per Clause 3, of IS 1161 ) Nominal Bore & Wall Thickness 100 mm NB with 3.6 mm Thickness,Grade Material as per table 2 of IS 1161 Not Applicable,Standing/ Sitting Twister Frame Pipe 40 mm Nominal Bore G.I. Pipe,Standing/ Sitting Twister Frame Pipe, Class as per IS 1239 Heavy,Standing/ Sitting Twister Frame Pipe (As per Clause 3, of IS 1161 ) Nominal Bore & Wall Thickness 40 mm NB with 2.9 mm Thickness,Rotating Disk Support Pipe at Bottom Pipe 100 mm Nominal Bore G.I. Pipe,Rotating Disk Support Pipe, Class as per IS 1239 Heavy,Rotating Disk Support Pipe ( as per IS 1161 ) as per Clause 3, Nominal Bore & Wall Thickness 100 mm NB with 5.4 mm Thickness,Grade Material (as per table 2 of IS 1161 ) Not Applicable,Handle Frame Pipe 32mm Nominal bore G.I. pipe,Handle Frame Pipe ( as per IS 1161 ) as per clause 3, Nominal Wall & Thickness 32 mm NB with 2.6 mm Thickness,Foundation Pipes with anchoring 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm, | Each | 65000.0 | 65000.0 | 2.0 | False | None | None | False | None | False | 130000.0 | 0 | 3345591 | 117574 | None | As per Gem Portal :Product id: 5116877-98041823890 | Providing supplying Fixing and Installation of Excel Three Wheel Shoulder Builder/ Arm Wheel- Outdoor Gym Equipment Having the Following Specification: Type Three Wheel,Height of Main Central Pole from ground 1500 millimeter,Outside Diameter of first wheel 900 millimeter,Outside Diameter of second wheel 750 millimeter,Height of first wheel from ground 1100 millimeter,Height of second wheel from ground 1000 millimeter,Height of third wheel from ground 1000 millimeter,Governing Specification for GI Pipes BIS specification No IS 1161:2014, latest,All the GI Pipes are ISI marked Yes,Designation of Main Central Pipe ( as per IS 1161 ) MEDIUM,Ring ( Wheel ) 32mm Nominal Bore G.I. Pipe,Designation of Ring ( Wheel ) Pipe ( as per IS 1161 ) MEDIUM,Pipe of Spokes of Wheel 15mm Nominal bore G.I. pipe,Connector Pipe ( between Main Central Pipe and Wheel ) 32 mm Nominal bore G.I. pipe,Foundation Pipes with anchoring 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm,nstruction Plate Stainless Steel, Size 150 X 230 X 0.7mm, with indelible printing, | Each | 141500.0 | 141500.0 | 1.0 | False | None | None | False | None | False | 141500.0 | 0 | 3345592 | 117574 | None | As per Gem Portal Product id: 5116877-97254876547 | Providing supplying Fixing and Installation of SG 1101- 1200 gram English Willow Cricket Bat Having the Following Specification: Material of Blade English Willow,Willow Grade Grade 2,Bat Sizes (Bat Length x Bat Width ) Short Handle ( 851 mm x 108 mm),Maximum Overall Depth 67 millimeter,Maximum Width at Edges 40 millimeter,Material of Handle Cane,Size of Handle Except for Bats of Size 6 and less, the handle shall not exceed 52% of overall length of bat.,Rubber Grip Yes,Shape of Handle Round,Mass of Cricket Bat ( Gram ) 1101- 1200,The bat shall be to pass through the bat gauge in accordance with MCC Law of cricket and overall Length of bat not more than 965 mm Yes,Face Coating Covered with Transparent protective coating,Grade of Bat ( As per the IS 828 -1979 Latest ) Grade II of IS 828-1979,Certification Details from International/ National Federations like International Cricket Council( ICC ) ie Certification Agency and Certificate No etc 20TH MARCH 2020 | Each | 11999.0 | 11999.0 | 1.0 | False | None | None | False | None | False | 11999.0 | 0 | 3345593 | 117574 | None | As per Gem Portal :Product id: 5116877-47817368893 | Providing supplying Fixing and Installation of APG SPORTS INDUSTRIES Alum tanned leather Red Cricket Ball Having the Following Specification: Ball Utility , Mass & Circumference Men's Cricket, 156 g to 163 g and 224 mm to 229 mm,Shape of Cricket Ball Spherical,Pieces 4 Piece,Colour Red,Inner Material of Ball ( Core ) Cork which is layered with tightly wound string,Material of String Wool,Outer Material of Ball Alum tanned leather,Water proof & Good abrasion resistance and excellent shape retention Yes,ype of Stitching Hand Stitching,Grade ( As per IS 10800 ) Grade 2, | Each | 870.0 | 870.0 | 2.0 | False | None | None | False | None | False | 1740.0 | 0 | 3345594 | 117574 | None | As per Gem Portal Product id: 5116877-65108565938 | Providing supplying Fixing and Installation of HRS A set of 6 Stumps and 4 Bails Having the Following Specification: Description A set of 6 Stumps and 4 Bails,Material of Stumps and Bails Hard Wood of Light colour with resistance to splitting,Length of Stump from playing surface 71.1 centimeter,Diameter of Stump 3.5 centimeter,Overall Length of Bail 10.95 centimeter,Length of Barrel of Bail 5.4 centimeter,Longer Spigot of Bail 3.49 centimeter,Shorter Spigot of Bail 2.06 centimeter,Stumps should have a spike at one end for inserting into the ground, and the other end has a cylindrical domed shaped except for groove to provide a resting place for the bails Yes,Projection of the bails when in position on top of the stumps The bails, when in position on top of the stumps, shall not project more than 1.27 cm above them., | Each | 2000.0 | 2000.0 | 1.0 | False | None | None | False | None | False | 2000.0 | 0 |
| 1719304221000 | 0 | None | None | Buildings | RO plant | 517482.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345595 | 117575 | None | Vol-5 I No. 21.1.9 Page no. 247 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref-detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 1000 LPH SS : Skid Type | Each | 463050.0 | 463050.0 | 1.0 | False | None | None | False | None | False | 463050.0 | 0 | 3345596 | 117575 | None | Vol-5 I No. 10.1.3 page No. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 50mm dia., 6 kg/sqcm & class 5 | m | 106.05 | 106.05 | 40.0 | False | None | None | False | None | False | 4242.0 | 0 | 3345597 | 117575 | None | Vol-5 I No. 13.28 Page no. 155 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 577.5 | 577.5 | 40.0 | False | None | None | False | None | False | 23100.0 | 0 | 3345598 | 117575 | None | Vol-5 I No. 13.22.4 Page No. 154 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 m2 | m | 194.25 | 194.25 | 40.0 | False | None | None | False | None | False | 7770.0 | 0 | 3345599 | 117575 | None | Vol-5 I No. 13.25.1 Page No. 154 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3345600 | 117575 | None | Vol-5 I No. 13.24.1 Page No. 154 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3345601 | 117575 | None | Vol-5 I No. 13.23.3 Page No. 155 | Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrical Protection Like Single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type of NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps | Each | 16695.0 | 16695.0 | 1.0 | False | None | None | False | None | False | 16695.0 | 0 |
| 1719304221000 | 0 | None | None | Buildings | ELECTRICAL WORK | 566714.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345602 | 117576 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe . mm
dia.mm thick confirming to IS 2509 with suitable size
bends, metal/PVC Junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered
using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 40.0 | False | None | None | False | None | False | 2640.0 | 0 | 3345603 | 117576 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm
dia.mm thick confirming to IS 2509 with suitable size
bends, metal/PVC Junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered
using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25mm dia 2mm thick | m | 78.0 | 78.0 | 200.0 | False | None | None | False | None | False | 15600.0 | 0 | 3345604 | 117576 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe . mm
dia.mm thick confirming to IS 2509 with suitable size
bends, metal/PVC Junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered
using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 32mm dia 2.5 mm thick | m | 103.0 | 103.0 | 100.0 | False | None | None | False | None | False | 10300.0 | 0 | 3345605 | 117576 | None | 1.2.4 | Supplying heavy gauge PVC conduit pipe . mm
dia.mm thick confirming to IS 2509 with suitable size
bends, metal/PVC Junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered
using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 40mm dia 2.5 mm thick | Mtr | 147.0 | 147.0 | 100.0 | False | None | None | False | None | False | 14700.0 | 0 | 3345606 | 117576 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. 19/20 mm dia 2 mm thick | Mtr | 68.0 | 68.0 | 100.0 | False | None | None | False | None | False | 6800.0 | 0 | 3345607 | 117576 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. 25mm dia 2mm thick | Mtr | 79.0 | 79.0 | 100.0 | False | None | None | False | None | False | 7900.0 | 0 | 3345608 | 117576 | None | 1.3.3 | Supplying heavy gauge PVC Conduit Pipe . dia . mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit
wherever necessary.32mm dia 2.5mm thick | Mtr | 99.0 | 99.0 | 40.0 | False | None | None | False | None | False | 3960.0 | 0 | 3345609 | 117576 | None | 1.3.4 | Supplying heavy gauge PVC Conduit Pipe . dia . mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. 40 mm dia 2.5mm thick | Mtr | 139.0 | 139.0 | 20.0 | False | None | None | False | None | False | 2780.0 | 0 | 3345610 | 117576 | None | 1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 40.0 | False | None | None | False | None | False | 1960.0 | 0 | 3345611 | 117576 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Each | 56.0 | 56.0 | 40.0 | False | None | None | False | None | False | 2240.0 | 0 | 3345612 | 117576 | None | 1.5.3 | Supplying and fixing PVC/metal conduit Deep junction box 32mm deep junction box | Each | 61.0 | 61.0 | 20.0 | False | None | None | False | None | False | 1220.0 | 0 | 3345613 | 117576 | None | 1.6.4 | Supplying and flush mounting teak wooden box without front
plank, made of not less than 12 mm thick wood, after due
groove cutting, finishing with necessary cement plastering
complete. 8" x 6" x 3" (203 x 152 x 76 mm | Each | 86.0 | 86.0 | 4.0 | False | None | None | False | None | False | 344.0 | 0 | 3345614 | 117576 | None | 2.1.1 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5mm2
(Phase & Neutral)
& 1x1.0 mm
2
(Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6A flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round
block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 285.0 | 285.0 | 20.0 | False | None | None | False | None | False | 5700.0 | 0 | 3345615 | 117576 | None | 2.1.2 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5mm2
(Phase & Neutral)
& 1x1.0 mm
2
(Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6A flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round
block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 394.0 | 394.0 | 10.0 | False | None | None | False | None | False | 3940.0 | 0 | 3345616 | 117576 | None | 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of
wiring with specified IS-694:confirming to latest amendments. 1 mm2 | m | 19.0 | 19.0 | 400.0 | False | None | None | False | None | False | 7600.0 | 0 | 3345617 | 117576 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of
wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 | 3345618 | 117576 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of
wiring with specified IS-694:confirming to latest amendments. 4 mm2 | m | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 | 3345619 | 117576 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of
wiring with specified IS-694:confirming to latest amendments. 6 mm2 | m | 92.0 | 92.0 | 30.0 | False | None | None | False | None | False | 2760.0 | 0 | 3345620 | 117576 | None | 2.3.6 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of
wiring with specified IS-694:confirming to latest amendments. 10 mm2 | m | 167.0 | 167.0 | 40.0 | False | None | None | False | None | False | 6680.0 | 0 | 3345621 | 117576 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches
for fixing switches, regulators etc, and fixing on existing
wooden or metal box using N.F. screws.
| Sq CM | 0.41 | 0.41 | 20000.0 | False | None | None | False | None | False | 8200.0 | 0 | 3345622 | 117576 | None | 3.10.2 | Extra for supplying 4 mm thick white plastic plate and
covering for junction boxes of size . mm conduit using
necessary machine screws. 80/90 mm | No | 15.0 | 15.0 | 50.0 | False | None | None | False | None | False | 750.0 | 0 | 3345623 | 117576 | None | 3.10.3 | Extra for supplying 4 mm thick white plastic plate and
covering for junction boxes of size . mm conduit using
necessary machine screws. 110 mm | No | 21.0 | 21.0 | 100.0 | False | None | None | False | None | False | 2100.0 | 0 | 3345624 | 117576 | None | 1.12 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 160.0 | 160.0 | 16.0 | False | None | None | False | None | False | 2560.0 | 0 | 3345625 | 117576 | None | 4.81 | Supplying industrial box type suitable for 28W T5 single / twin Lamp along with stove enameled white reflector & suspension mounted luminaire & optical reflector. Prewired with HF electronic Ballast, push fit type lamp holders & main connectors. Channel c | Each | 1328.7 | 1328.7 | 80.0 | False | None | None | False | None | False | 106296.0 | 0 | 3345626 | 117576 | None | 6.2.2 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450mm) Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifica | Each | 4446.0 | 4446.0 | 10.0 | False | None | None | False | None | False | 44460.0 | 0 | 3345627 | 117576 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) | Each | 2984.0 | 2984.0 | 30.0 | False | None | None | False | None | False | 89520.0 | 0 | 3345628 | 117576 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wal | Each | 122.0 | 122.0 | 80.0 | False | None | None | False | None | False | 9760.0 | 0 | 3345629 | 117576 | None | 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire o | Each | 315.0 | 315.0 | 30.0 | False | None | None | False | None | False | 9450.0 | 0 | 3345630 | 117576 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated | Each | 707.0 | 707.0 | 10.0 | False | None | None | False | None | False | 7070.0 | 0 | 3345631 | 117576 | None | 5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to
IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum
IP43 protection provided with Polyurethane (PUR) gasket, with
suitable earthing system, on wall/wood board/flush mounting using
required cl A , bolts, nuts, etc., with provision for fixing of suitable
type capacity MCCB's as an incomer for 3 phase Double door with
necessary bus bar completely wired to use on 440V 3phase 4 wire
powder coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings confirming to
IS/IEC 60898 - 2. 12 Way | Each | 15529.0 | 15529.0 | 2.0 | False | None | None | False | None | False | 31058.0 | 0 | 3345632 | 117576 | None | 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A SP Switch | Each | 55.0 | 55.0 | 20.0 | False | None | None | False | None | False | 1100.0 | 0 | 3345633 | 117576 | None | 3.14.5 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Bakelite Ceiling Rose | Each | 78.0 | 78.0 | 40.0 | False | None | None | False | None | False | 3120.0 | 0 | 3345634 | 117576 | None | 12.6 | Supplying and replacing ceiling fan regulator 900mm to 1500mm. | Each | 382.0 | 382.0 | 30.0 | False | None | None | False | None | False | 11460.0 | 0 | 3345635 | 117576 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as | Each | 9315.0 | 9315.0 | 2.0 | False | None | None | False | None | False | 18630.0 | 0 | 3345636 | 117576 | None | 7.4.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of high quality Evacuated Glass Tube (EGT) with
absorber coating collector of size 58 x 1800 mm. Inner tank MaterialStainless steel 304-L Grade with Aluminium Stucco cladding made of
High quality PUF insulation to minimizes heat loss and hold water
Temperature upto 72 Hrs.with appropriate capacity electrical back
up arrangement excluding inlet and out let pipes. Fitted with Sacrificial
Anode 300 L-29 nos Tubes | Each | 51528.0 | 51528.0 | 2.0 | False | None | None | False | None | False | 103056.0 | 0 |
| 1719304221000 | 0 | None | None | Buildings | TOILET | 3446899.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345637 | 117577 | None | Vol-1 Item No. 1.14.1 Pg.No 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 162.8 | False | None | None | False | None | False | 17435.88 | 0 | 3345638 | 117577 | None | Si No 2.1.4 Vol 1, Page No15, PWD CSR Vol 1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 22.13 | False | None | None | False | None | False | 144461.3205 | 0 | 3345639 | 117577 | None | I No. 5.4 Vol-II | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 23.74 | False | None | None | False | None | False | 159258.603 | 0 | 3345640 | 117577 | None | Vol-I I No. 1.9 Page No. 7 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 23.74 | False | None | None | False | None | False | 6630.582 | 0 | 3345641 | 117577 | None | DSR 2023-24 Vol-1 Item No. 1.8 Pg.No 7 | Construction of Embankment by excavating the available approved Gravel/
Murrum deposited at a place or borrow pits during or prior excavation with all
lifts and lead, transportation to site, spreading, grading to required slope and
compacting to meet the requirement complete as per specifications, including
cost of labour,rolling,water,all materials,usage& all other appurtenaces required
to complete the work. | Cum | 497.7 | 497.7 | 65.12 | False | None | None | False | None | False | 32410.224 | 0 | 3345642 | 117577 | None | DSR 2023-24 Vol-1 Item No.2.2.3 Pg.No 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 51.72 | False | None | None | False | None | False | 344082.816 | 0 | 3345643 | 117577 | None | Si No -02 Appendix Vol 1 | Form Work Cost 70 Percent on columns | Cum | 4656.96 | 4656.96 | 6.83 | False | None | None | False | None | False | 31807.0368 | 0 | 3345644 | 117577 | None | Si No -02 Appendix Vol 2 | 60 Percent on beams | Cum | 3991.68 | 3991.68 | 11.24 | False | None | None | False | None | False | 44866.4832 | 0 | 3345645 | 117577 | None | Si No -02, Appendix Vol 3 | 50 Percent on roof | Cum | 3326.4 | 3326.4 | 16.21 | False | None | None | False | None | False | 53920.944 | 0 | 3345646 | 117577 | None | Vol-I S R I No. 2.11 a Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.Buildings | t | 93929.85 | 93929.85 | 3.621 | False | None | None | False | None | False | 340119.98685 | 0 | 3345647 | 117577 | None | Vol-2 Item No.6.7 Pg.No 13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8621.55 | 8621.55 | 60.08 | False | None | None | False | None | False | 517982.724 | 0 | 3345648 | 117577 | None | Vol-II I No. 6.12 page No. 14 | Providing Half brick masonry with common burnt clay Non Modular bricks
of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1
cement : 3 coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges complete as
per the direction of engineer incharge of work. | Sqm | 1053.15 | 1053.15 | 100.26 | False | None | None | False | None | False | 105588.819 | 0 | 3345649 | 117577 | None | Vol-2 Item No.8.1.1 Pg.No 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 177.09 | False | None | None | False | None | False | 47415.8475 | 0 | 3345650 | 117577 | None | Vol-2 Si No.8.9 Pg.No 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 248.51 | False | None | None | False | None | False | 100460.1675 | 0 | 3345651 | 117577 | None | Vol-2 Item No.8.51 Pg.No 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 177.09 | False | None | None | False | None | False | 18594.45 | 0 | 3345652 | 117577 | None | Vol-2 Si No.8.27 Pg.No 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 177.09 | False | None | None | False | None | False | 9855.0585 | 0 | 3345653 | 117577 | None | Vol-2 Si No.8.39 Pg.No 48 | Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 177.09 | False | None | None | False | None | False | 23614.9515 | 0 | 3345654 | 117577 | None | Vol-2 Si No.8.29 Pg.No 45 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 372.84 | False | None | None | False | None | False | 110789.406 | 0 | 3345655 | 117577 | None | Vol-2 I No. 9.7.2 Pg.No 59 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse
sand) with Acid and alkali resistant tile | Sqm | 1323.0 | 1323.0 | 108.53 | False | None | None | False | None | False | 143585.19 | 0 | 3345656 | 117577 | None | Vol-2 I No.9.39 Pg.No 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1521.45 | 1521.45 | 249.48 | False | None | None | False | None | False | 379571.346 | 0 | 3345657 | 117577 | None | Vol-II I No. 11.44 Page No. 91 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float
glass both side, having 12 mm air gap, including providing EPDM gasket,
perforated aluminium spacers, desiccants, sealant (Both primary and
secondary sealant) etc. as per specifications, drawings and direction of
Engineer-in-charge complete including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge | Sqm | 4562.25 | 4562.25 | 8.1 | False | None | None | False | None | False | 36954.225 | 0 | 3345658 | 117577 | None | Vol-2 Item No.12.57.2 Pg.No 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercial | Sqm | 3667.65 | 3667.65 | 18.0 | False | None | None | False | None | False | 66017.7 | 0 | 3345659 | 117577 | None | Vol-2 Item No.12.51 Pg.No 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 18.0 | False | None | None | False | None | False | 19202.4 | 0 | 3345660 | 117577 | None | Vol-2 Page No 78, Item No.11.6.3 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2388.75 | 2388.75 | 6.3 | False | None | None | False | None | False | 15049.125 | 0 | 3345661 | 117577 | None | Vol-5 Item No.16.8 Page No. 191 | Constructing brick masonry chamber of internal dimension 600x450mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing
CI cover & frame etc. excluding the cost of CI frame and cover | No | 5030.55 | 5030.55 | 6.0 | False | None | None | False | None | False | 30183.3 | 0 | 3345662 | 117577 | None | Vol-5 I No. 9.1.4 Page No. 95 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,110mm dia | m | 492.45 | 492.45 | 40.0 | False | None | None | False | None | False | 19698.0 | 0 | 3345663 | 117577 | None | Vol-5 I No. 10.1.7 Page No. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations andccuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangementsfor procuring water for testing) etc. for:110 mm dia. pipes | m | 431.55 | 431.55 | 80.0 | False | None | None | False | None | False | 34524.0 | 0 | 3345664 | 117577 | None | Vol-II I No. 13.31.3 Page No. 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 25 mm nominal dia Pipes | m | 333.9 | 333.9 | 50.0 | False | None | None | False | None | False | 16695.0 | 0 | 3345665 | 117577 | None | Vol-II I No. 14.32.2 Page No. 136 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm | Each | 1068.9 | 1068.9 | 6.0 | False | None | None | False | None | False | 6413.4 | 0 | 3345666 | 117577 | None | DSR 2018-19 Item No.90 12.113.2 | Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms | No | 299.25 | 299.25 | 24.0 | False | None | None | False | None | False | 7182.0 | 0 | 3345667 | 117577 | None | Vol-2 Item No.14.7.7 Page no. 133 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
taps, 32 mm C.P. brass waste of standard pattern, including painting of
fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | Each | 2203.95 | 2203.95 | 12.0 | False | None | None | False | None | False | 26447.4 | 0 | 3345668 | 117577 | None | Vol-2 Item No.13.26 Page No. 121 | Providing and fixing PTMT soap Dish Holder having length of 138mm,
breadth 102mm, height of 75mm with concealed fitting arrangements,
weighing not less than 106 g. | No | 105.0 | 105.0 | 36.0 | False | None | None | False | None | False | 3780.0 | 0 | 3345669 | 117577 | None | Vol-2 Item No.13.2.2 Page No. 117 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | No | 320.25 | 320.25 | 40.0 | False | None | None | False | None | False | 12810.0 | 0 | 3345670 | 117577 | None | Item No 14.40.2 Vol 2 Page No. 137 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g. | Each | 520.8 | 520.8 | 20.0 | False | None | None | False | None | False | 10416.0 | 0 | 3345671 | 117577 | None | Item No 14.16A Vol 2 Page No. 134 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre
long with S.S. triangular plate to Eureopean type W.C. of quality and make
as approved by Engineer - in - charge | Each | 285.6 | 285.6 | 10.0 | False | None | None | False | None | False | 2856.0 | 0 | 3345672 | 117577 | None | Item No 14.35.1 Vol 2 Page No. 137 | Providing and fixing vitreous china dual purpose closet suitable for
use as squatting pan or European type water closet (Anglo Indian W.C
pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre
low level flushing cistern with fitting and brackets, 40 mm flush bend, 20
mm over flow pipe, with specials of standard make and mosquito proof
coupling of approved municipal design complete, including painting
of fittings and brackets, cutting and making good the walls and floors
wherever required: White vitreous china dual purpose WC pan with white solid plastic seat
and lid with white vitreous china flushing cistern and C.P. flush bend. | Each | 9063.6 | 9063.6 | 10.0 | False | None | None | False | None | False | 90636.0 | 0 | 3345673 | 117577 | None | Item No 14.13.2 Vol 2 Page No. 134 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern WC pan of size 50x440mm | Each | 2447.55 | 2447.55 | 8.0 | False | None | None | False | None | False | 19580.4 | 0 | 3345674 | 117577 | None | DSR 2021-22 Vol-2 Item No.13.34 | providing and placing on terrace ( at all floor levels) polythlene water storage tank IS:12701 marked with cover and suitable locking arragements and making necessary holes,inlets, outlets and overflow pipes but without fittings and base support for tank as per corrigendum-1 | l | 8.4 | 8.4 | 4000.0 | False | None | None | False | None | False | 33600.0 | 0 | 3345675 | 117577 | None | Item No 1.14.1 Vol-I Page No. 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 54.0 | False | None | None | False | None | False | 5783.4 | 0 | 3345676 | 117577 | None | Item No 2.1.2 Vol-I Page No. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.8 | False | None | None | False | None | False | 10704.96 | 0 | 3345677 | 117577 | None | Item No 2.2.2 Vol-I Page No. 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
with 20% partial replacement with Recycled concrete aggregate (RCA) | Cum | 6560.4 | 6560.4 | 19.44 | False | None | None | False | None | False | 127534.176 | 0 | 3345678 | 117577 | None | Vol-I I No. 2.11 a Page no. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. Buildings | t | 93929.85 | 93929.85 | 0.862 | False | None | None | False | None | False | 80967.5307 | 0 | 3345679 | 117577 | None | Si No -02, Appendix, Vol 1 | centring slab Sub structure of Cross drainages | Cum | 3280.2 | 3280.2 | 19.44 | False | None | None | False | None | False | 63767.088 | 0 | 3345680 | 117577 | None | Item No 1.14.1 Vol-I Page No. 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 36.0 | False | None | None | False | None | False | 3855.6 | 0 | 3345681 | 117577 | None | Vol-5 I No. 16.1.2 Page No. 187 | Providing, lowering, laying, jointing, testing and commissioning of Glazed
Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127
with latest amendments, including conveying to work site, caulking
with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect
linking and curing for 10 days and testing with water etc. with all lead,
lifts and as per Technical Specifications. The cost to include the cost of
all jointing materials, necessary survey works for laying of sewer lines
etc. complete. The contractor will make own arrangements for procuring
water for testing. 150 mm dia. pipes | m | 610.05 | 610.05 | 30.0 | False | None | None | False | None | False | 18301.5 | 0 | 3345682 | 117577 | None | Item No 1.9 Vol -1 Page No. 7 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 32.4 | False | None | None | False | None | False | 9049.32 | 0 | 3345683 | 117577 | None | Vol-5 I No. 16.60.1 Page No. 208 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which
shall be laid from inside the customer property ) which includes: a)
Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE
Inspection chambres with lid consisting of inlet & outlet arrangements
with base, riser of min. 0.42 m depth which includes earth work,
fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like
Earthwork excavation for the pipeline trenches for laying of PVC-U pipes
for the house connections in all types of soils , disintegrated rock,soft
rock, hard rock, including cutting of any road using , crossing drains,
compound, Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, c.c. wood
work, steel work, including T & P and scaffolding wherever necessary
sorting the dismantled material, disposal of unserviceable and stacking
the serviceable material with all lifts and lead , restoring the damaged
portions inside or outside the property premises, refilling the portions
of trenches that are dug open including linking to existing sewer network
with appurtenances. complete 110 mm dia | Each | 8540.7 | 8540.7 | 4.0 | False | None | None | False | None | False | 34162.8 | 0 | 3345684 | 117577 | None | Vol-I S R Sl No. 1 a Page No. 111 | Form Work Cost 8 Percent on Footing | Cum | 532.22 | 532.22 | 15.55 | False | None | None | False | None | False | 8276.021 | 0 |
| 1719304221000 | 0 | None | None | Buildings | C.C ROAD | 875474.04 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345685 | 117578 | None | Vol-I I No. 1.1 Page No. 5 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Cum | 95.55 | 95.55 | 84.0 | False | None | None | False | None | False | 8026.2 | 0 | 3345686 | 117578 | None | Vol-III I No. 3.6 Page No. 17 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 84.0 | False | None | None | False | None | False | 43482.6 | 0 | 3345687 | 117578 | None | Vol-III I No. 4.2.V Page No. 23 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2476.95 | 2476.95 | 56.0 | False | None | None | False | None | False | 138709.2 | 0 | 3345688 | 117578 | None | Vol-III I No. 4.17 Page No. 26 | Providing, laying, spreading and compacting graded stone
aggregate to wet mix macadam specification including premixing
the Material with water at OMC in mechanical mix plant carriage
of mixed Material by tipper to site, laying in uniform layers with
paver/grader in sub-base / base course on well prepared surface
and compacting with vibratory roller to achieve the desired density. | Cum | 2686.95 | 2686.95 | 42.0 | False | None | None | False | None | False | 112851.9 | 0 | 3345689 | 117578 | None | Vol-III I No. 16.27 Page No. 148 | Providing and constructing un-reinforced plain cement
concrete pavement, thickness as per design, over a prepared
sub base, with 43 grade cement or any other type as per
Clause 1501.2.2 M20 (Grade), coarse and fine aggregates
conforming to IS:383:2016, maximum size of coarse
aggregate not exceeding 25 mm, mixed in a concrete mixer
of not less than 0.2 cum capacity and appropriate weigh
batcher using approved mix design, laid in approved fixed
side formwork (steel channel, laying and fixing of 125 micron
thick polythene film, wedges, steel plates including levelling
the formwork as per drawing), spreading the concrete with
shovels, rakes, compacted using needle, screed and plate | Cum | 6692.7 | 6692.7 | 84.0 | False | None | None | False | None | False | 562186.8 | 0 | 3345690 | 117578 | None | Vol-III I No. 8.7 Page No. 65 | Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing | Sqm | 9460.5 | 9460.5 | 1.08 | False | None | None | False | None | False | 10217.34 | 0 |
| 1719304221000 | 0 | None | None | Buildings | 100 KVAC | 500000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3345691 | 117579 | None | Item 1 | Estimate for providing an additional 100 kva DTC at near Degree. Collage to bifurcate the overloded 63 kva albal tower TC in Jevargi town ( under self execution) | No | 500000.0 | 500000.0 | 1.0 | False | None | None | False | None | False | 500000.0 | 0 |
|
|
---|