createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719291317603
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1000.00
emd80000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose03-07-2024 17:00:00
tenderQueryClose29-06-2024 16:00:00
technicalBidOpen04-07-2024 17:20:00
publishedDate25-06-2024 18:06:59
publishedByPostTMC_CO_KMPR
publishedByUserKPE13402 - MAHANTESH H BILAGI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonT S Hanumantha
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9481565634
tenderSupplierListNone
tenderSchedule
createdTs1719291317664
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT18590
titleConstruction of Proposed 3TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) at Kamalapura
descriptionConstruction of Proposed 3TPD MRF Centre Material Recovery Facility of PEB Structure PRIMARY SECONDARY SHED at Kamalapura
categoryWORKS
categoryTextWorks
ecv4000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2476
locationNameDMA Town Municipal Council Kamalapur
provisionalAmount4000000.0
groupOverheadTotal638671.11
fileNumberNO/01/KML/MPC/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17192913180000NoneNoneOther WorksConstruction of Proposed 3TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) at Kamalapura3361328.89
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3340914117360NoneKML01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum107.1107.136.64FalseNoneNoneFalseNoneFalse3924.1440
3340915117360NoneKML02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.236.18FalseNoneNoneFalseNoneFalse215169.6960
3340916117360NoneKML03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) including centering charges for footingCum7322.47322.49.04FalseNoneNoneFalseNoneFalse66194.4960
3340917117360NoneKML04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) including centering charges for Column baseCum11340.011340.01.94FalseNoneNoneFalseNoneFalse21999.60
3340918117360NoneKML05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) including centering charges for Hall grade slabCum7322.47322.440.7FalseNoneNoneFalseNoneFalse298021.680
3340919117360NoneKML06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9820.89820.85.98FalseNoneNoneFalseNoneFalse58728.3840
3340920117360NoneKML07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE550D Steel Reinforcement including cost of all materials, machinery, labour,cleaning, straighteningt93929.8593929.853.71FalseNoneNoneFalseNoneFalse348479.74350
3340921117360NoneKML08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4517.43FalseNoneNoneFalseNoneFalse116928.28350
3340922117360NoneKML09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum497.7497.7183.14FalseNoneNoneFalseNoneFalse91148.7780
3340923117360NoneKML10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1292.551292.55106.06FalseNoneNoneFalseNoneFalse137087.8530
3340924117360NoneKML11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm309.75309.75225.61FalseNoneNoneFalseNoneFalse69882.69750
3340925117360NoneKML12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs118.65118.658380.0FalseNoneNoneFalseNoneFalse994287.00
3340926117360NoneKML13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm596.4596.4590.76FalseNoneNoneFalseNoneFalse352329.2640
3340927117360NoneKML14KSRB 8-8.51 : Providing and applying white cement based putty of average thicknessSqm105.0105.0225.61FalseNoneNoneFalseNoneFalse23689.050
3340928117360NoneKML15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.65106.06FalseNoneNoneFalseNoneFalse8129.4990
3340929117360NoneKML16KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)Sqm76.6576.65106.06FalseNoneNoneFalseNoneFalse8129.4990
3340930117360NoneKML17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.6522.5FalseNoneNoneFalseNoneFalse62204.6250
3340931117360NoneKML18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)Each25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3340932117360NoneKML19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kgs474.6474.6240.0FalseNoneNoneFalseNoneFalse113904.00
3340933117360NoneKML20Fabricating supplying and mounting MSboxmade out ....SWG suitableforfloor /wallmounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof lockingarrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete. PWD Ele SR 2-23-24 Page No 20 I No 5.42.2 16 SWGSqm0.450.4543000.0FalseNoneNoneFalseNoneFalse19350.00
3340934117360NoneKML21Supplying and fixing Moulded Case Circui t Breaker (M CCB) overthe existing wood/panel board screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Over loadand Short circuit with adjustable the rmal magnetic release Microprocessor release shall have EarthFaultasperIS/IEC60947-2.(Icu=100%lcs). In4PMCCB, all Poles shouldhaveprotection forShort-Cicrcuit/OverLoad. ForMicroprocesso rMCCBS Facility for segregating Priority and Non-Priority loads must beavailable in theMCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits toavoidanyaccidentalcontactwith live current carryingpathwith the front cover open) Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. PWD ELE SR 2023-24 Page No 17 I No 5.15.9 100 A 25 kA Four PoleEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3340935117360NoneKML22Aluminium Busbar/Wire Pieces. ESCOM SR 2023-24 Page No 33 I No 69.04Kgs142.8142.80.5FalseNoneNoneFalseNoneFalse71.40
3340936117360NoneKML23Supplyingof Switch disconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.612.0FalseNoneNoneFalseNoneFalse29131.20
3340937117360NoneKML24Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3340938117360NoneKML25Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5512.0FalseNoneNoneFalseNoneFalse3666.60
3340939117360NoneKML26Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.1 6A TO 16 AEach345.45345.4512.0FalseNoneNoneFalseNoneFalse4145.40
3340940117360NoneKML27SUB PANEL :Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 withShort circuitbreakingcapacity of 10 Kandcomplete wiring as required confirming to IEC60898 PWD ELE SR PAGE NO 17 I NO : 5.18.9 50-63 A TPNEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3340941117360NoneKML28Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.612.0FalseNoneNoneFalseNoneFalse29131.20
3340942117360NoneKML29Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3340943117360NoneKML30Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5512.0FalseNoneNoneFalseNoneFalse3666.60
3340944117360NoneKML31Outgoings: 32A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.2Each575.48575.482.0FalseNoneNoneFalseNoneFalse1150.960
3340945117360NoneKML32Outgoings: 16A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.1Each407.15407.152.0FalseNoneNoneFalseNoneFalse814.30
3340946117360NoneKML331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Mtr187.92187.92100.0FalseNoneNoneFalseNoneFalse18792.00
3340947117360NoneKML341.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Mtr188.84188.84100.0FalseNoneNoneFalseNoneFalse18884.00
3340948117360NoneKML351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Mtr148.93148.9350.0FalseNoneNoneFalseNoneFalse7446.50
3340949117360NoneKML361.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Mtr123.9123.950.0FalseNoneNoneFalseNoneFalse6195.00
3340950117360NoneKML37Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 4Cx6.0 Sqmm Cu Ar cable ,3Cx6.0 Sqmm Cu Un Ar cable 3Cx 4.00 Sqmm ESCOM Page No 52 I NO 21.05Mtr21.9321.93100.0FalseNoneNoneFalseNoneFalse2193.00
3340951117360NoneKML38Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr72.4572.4590.0FalseNoneNoneFalseNoneFalse6520.50
3340952117360NoneKML39Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 25mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr85.0585.0590.0FalseNoneNoneFalseNoneFalse7654.50
3340953117360NoneKML40Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 32mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr111.3111.3100.0FalseNoneNoneFalseNoneFalse11130.00
3340954117360NoneKML41Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 40mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr156.45156.4520.0FalseNoneNoneFalseNoneFalse3129.00
3340955117360NoneKML42Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.9519.95150.0FalseNoneNoneFalseNoneFalse2992.50
3340956117360NoneKML43Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr27.327.3150.0FalseNoneNoneFalseNoneFalse4095.00
3340957117360NoneKML44Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 2.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr44.144.1100.0FalseNoneNoneFalseNoneFalse4410.00
3340958117360NoneKML45Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 4 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr52.552.5100.0FalseNoneNoneFalseNoneFalse5250.00
3340959117360NoneKML466 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr52.552.550.0FalseNoneNoneFalseNoneFalse2625.00
3340960117360NoneKML47Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5Nos299.25299.254.0FalseNoneNoneFalseNoneFalse1197.00
3340961117360NoneKML48Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos413.7413.78.0FalseNoneNoneFalseNoneFalse3309.60
3340962117360NoneKML49Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5Nos598.5598.56.0FalseNoneNoneFalseNoneFalse3591.00
3340963117360NoneKML50Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3340964117360NoneKML51Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos757.05757.054.0FalseNoneNoneFalseNoneFalse3028.20
3340965117360NoneKML52Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 3 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1086.751086.754.0FalseNoneNoneFalseNoneFalse4347.00
3340966117360NoneKML53Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos107.1107.16.0FalseNoneNoneFalseNoneFalse642.60
3340967117360NoneKML54Switches & sockets outlets in Existing modular box 6A Three Way 5 Pin Socket CSR Electrical SR-2023-24, ITEM NO:3.14.3 ,CH-3, PAGE NO-10Nos73.573.54.0FalseNoneNoneFalseNoneFalse294.00
3340968117360NoneKML55Switches & sockets outlets in Existing modular box Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9Nos374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
3340969117360NoneKML56Switches & sockets outlets in Existing modular box 6/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3340970117360NoneKML57SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenanceof percent maximumlightintensityshouldbebetween 60degrees to 70degrees CCT5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaireIK08. Power Factor0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ...WSystem Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agencyandDesignandDevelopment facility certified by ISO9001:2008. Housingwith supplierwordmarkname shallbeEngravedEmbossingonthediecasthousing/Bodypart.Warrantyof2Yearsagainstanymanufacturindefectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/Lumileds/Osram make LED Source CSR Electrical SR-2023-24, ITEM NO:11.8.2, PAGE NO-46Nos4225.24225.212.0FalseNoneNoneFalseNoneFalse50702.40
3340971117360NoneKML58Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Volume - V Water supply SR 2023-24Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3340972117360NoneKML59Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) VOL-6 KPTCL PG NO 120 . I no 22Mtr791.7791.750.0FalseNoneNoneFalseNoneFalse39585.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17192913190000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17192913190000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17192913190000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17192913190000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17192913190000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17192914700000NoneNoneELIGIBILITYBidders shall upload documents as per tender criteriaNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contrct each tenderer in its name should have in the Last five years i.e 2019-20 to 2023-24 mandatory Satisfactory completion as a prime contractor for at least one similar nature of work done 50 percent of total cost of works Attested by not below the ranking of Executive Engineer to extend of Rs 20 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneContract Registration Certificate Registration Certificate issued by PWD officer not below the ranking of Chief engineerCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAnnual Turnover certificate for last five years 2019-20 to 2023-24 certified balance sheet by charted accountant and Achieved at last two year an average annual financial turnover Rs 40.00 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than amount Rs.12.00 Lakhs in the form of credit lines or Letter of credit all certificate from Bank for meeting the fund required (Conditional bankers certificate not accepatable)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneupload all relevant documents as per technical criteria and bid document conditionsOthersupload all relevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- upload all relevant documents
NoneNoneNoneNoneValid PAN CARDOthersValid PAN CARD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid PAN CARD
NoneNoneNoneNoneValid GST Registration certificateOthersGST
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneAddress Details and Contact NumberOthersAddress Details and Contact Number
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Address Details and Contact Number
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate issued by PWD officer not below the ranking of Chief engineerTrueTechnical Bid
Annual Turnover Certificate 2019-20 to 2023-24TrueTechnical Bid
Mandatory Satisfactory completion as a prime contractor for at least 1 similar nature of work done 50 percent of total cost of works Attested by not below the ranking of Executive EngineerTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than amount Rs.120000 Attach Credit lines or letter of credit or Banker certificates issued by scheduled bank Un conditionalTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
PAN CARDTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone