createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719315944799
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd871000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 16:00:00
tenderQueryClose04-07-2024 16:00:00
technicalBidOpen12-07-2024 16:00:01
publishedDate25-06-2024 17:26:31
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate06-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1719315944829
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT447
titlePackageVJN (9 Works) Construction of Health and Wellness Centerat 1) Nicchavanahalli, 2) Kadabagere, 3)Madiagere in Harapanahali Tq 4) Malavi, 5) Bannigolu, 6) Mutkuru in H B Halli Tq 7) Moraba, 8) Hegdalu, 9) Dananayakannakere in Kudligi Tq in Vijayanagara District
descriptionPackageVJN (9 Works) 1) Construction of Health and Wellness Center at Nicchavanahalli Harapanahalli Taluk in Vijayanagara District, 2) Construction of Health and Wellness Center at Kadabagere Harapanahali Taluk in Vijayanagara District, 3) Construction of Health and Wellness Center at Madiagere in Harapanahali Taluk in Vijayanagara District, 4) Construction of Health and Wellness Center at Malavi Hagaribomanahhali Taluk in Vijayanagara District, 5) Construction of Health and Wellness Center at Bannigolu Hagaribomanahhali Taluk in Vijayanagara District, 6) Construction of Health and Wellness Center at Mutkuru Hagaribomanahhali Taluk in Vijayanagara District, 7) Construction of Health and Wellness Center at Moraba in Kudligi Taluk in Vijayanagara District, 8) Construction of Health and Wellness Center at Hegdalu in Kudligi Taluk in Vijayanagara District and 9) Construction of Health and Wellness Center at Dananayakannakere in Kudligi Taluk in Vijayanagara District
categoryWORKS
categoryTextWorks
ecv58058611.97
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount58500000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/BLY/PackageVJN/15F/HWC/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17193159450000NoneNoneBuildingsNicchavanahalli-Ground Floor3468715.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350345117821NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3350346117821NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3350347117821NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3350348117821NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3350349117821NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3350350117821NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3350351117821NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3350352117821NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3350353117821NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3350354117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3350355117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3350356117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3350357117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3350358117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3350359117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3350360117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3350361117821NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3350362117821NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3350363117821NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3350364117821NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3350365117821NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3350366117821NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3350367117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3350368117821NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3350369117821NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3350370117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3350371117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3350372117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3350373117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3350374117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3350375117821NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3350376117821NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3350377117821NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3350378117821NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3350379117821NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3350380117821NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3350381117821NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3350382117821NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3350383117821NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3350384117821NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3350385117821NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3350386117821NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3350387117821NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3350388117821NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3350389117821NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.366.76FalseNoneNoneFalseNoneFalse22749.83360
3350390117821NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3350391117821NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3350392117821NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3350393117821NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3350394117821NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3350395117821NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3350396117821NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3350397117821NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3350398117821NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3350399117821NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsNicchavanahalli-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350400117822NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3350401117822NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3350402117822NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3350403117822NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3350404117822NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3350405117822NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3350406117822NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3350407117822NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3350408117822NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3350409117822NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3350410117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3350411117822NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3350412117822NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3350413117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3350414117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3350415117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3350416117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3350417117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3350418117822NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3350419117822NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3350420117822NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3350421117822NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3350422117822NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3350423117822NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3350424117822NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3350425117822NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3350426117822NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3350427117822NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3350428117822NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3350429117822NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3350430117822NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3350431117822NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3350432117822NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3350433117822NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3350434117822NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3350435117822NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3350436117822NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3350437117822NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3350438117822NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3350439117822NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3350440117822NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3350441117822NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3350442117822NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3350443117822NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3350444117822NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsNicchavanahalli-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350445117823NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3350446117823NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3350447117823NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3350448117823NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3350449117823NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3350450117823NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3350451117823NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3350452117823NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3350453117823NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3350454117823NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3350455117823NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3350456117823NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3350457117823NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3350458117823NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3350459117823NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3350460117823NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3350461117823NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3350462117823NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3350463117823NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3350464117823NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3350465117823NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsNicchavanahalli-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350466117824NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3350467117824NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3350468117824NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3350469117824NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3350470117824NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3350471117824NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3350472117824NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3350473117824NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3350474117824NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3350475117824NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3350476117824NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3350477117824NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3350478117824NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3350479117824NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3350480117824NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3350481117824NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3350482117824NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3350483117824NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3350484117824NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3350485117824NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3350486117824NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3350487117824NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3350488117824NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3350489117824NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3350490117824NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3350491117824NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3350492117824NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3350493117824NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3350494117824NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3350495117824NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3350496117824NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3350497117824NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3350498117824NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3350499117824NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3350500117824NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3350501117824NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3350502117824NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3350503117824NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3350504117824NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3350505117824NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3350506117824NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3350507117824NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3350508117824NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3350509117824NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3350510117824NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3350511117824NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3350512117824NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3350513117824NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3350514117824NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3350515117824NonePWD V-6 ITNO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3350516117824NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3350517117824NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3350518117824NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3350519117824NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3350520117824NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3350521117824NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3350522117824NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3350523117824NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsNicchavanahalli-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350524117825NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3350525117825NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3350526117825NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350527117825NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3350528117825NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3350529117825NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3350530117825NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3350531117825NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3350532117825NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3350533117825NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350534117825NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350535117825NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3350536117825NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsNicchavanahalli-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350537117826NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3350538117826NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3350539117826NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350540117826NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3350541117826NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3350542117826NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3350543117826NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3350544117826NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3350545117826NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350546117826NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350547117826NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsNicchavanahalli-Demolition of Existing Building85831.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350548117827NonePWD Volume- 2 SR 2023-24 Page No-187 It No-19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum3005.813005.8110.8FalseNoneNoneFalseNoneFalse32462.7480
3350549117827NonePWD Volume- 2 SR 2023-24 Page No-187 It No-19.7.1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum597.2597.221.9FalseNoneNoneFalseNoneFalse13078.680
3350550117827NonePWD Volume- 1 SR 2023-24 Page No-187 It No-19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. In cement mortarCum2086.482086.4819.31FalseNoneNoneFalseNoneFalse40289.92880
17193159450000NoneNoneBuildingsKadabagere-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350551117828NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3350552117828NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3350553117828NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3350554117828NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3350555117828NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3350556117828NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3350557117828NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3350558117828NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3350559117828NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3350560117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3350561117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3350562117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3350563117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3350564117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3350565117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3350566117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3350567117828NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3350568117828NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3350569117828NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3350570117828NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3350571117828NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3350572117828NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3350573117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3350574117828NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3350575117828NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3350576117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3350577117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3350578117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3350579117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3350580117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3350581117828NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3350582117828NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3350583117828NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3350584117828NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3350585117828NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3350586117828NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3350587117828NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3350588117828NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3350589117828NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3350590117828NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3350591117828NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3350592117828NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3350593117828NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3350594117828NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3350595117828NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3350596117828NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3350597117828NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3350598117828NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3350599117828NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3350600117828NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3350601117828NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3350602117828NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3350603117828NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3350604117828NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3350605117828NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsKadabagere-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350606117829NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3350607117829NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3350608117829NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3350609117829NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3350610117829NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3350611117829NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3350612117829NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3350613117829NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3350614117829NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3350615117829NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3350616117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3350617117829NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3350618117829NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3350619117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3350620117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3350621117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3350622117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3350623117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3350624117829NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3350625117829NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3350626117829NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3350627117829NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3350628117829NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3350629117829NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3350630117829NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3350631117829NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3350632117829NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3350633117829NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3350634117829NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3350635117829NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3350636117829NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3350637117829NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3350638117829NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3350639117829NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3350640117829NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3350641117829NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3350642117829NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3350643117829NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3350644117829NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3350645117829NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3350646117829NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3350647117829NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3350648117829NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3350649117829NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3350650117829NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsKadabagere-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350651117830NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3350652117830NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3350653117830NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3350654117830NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3350655117830NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3350656117830NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3350657117830NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3350658117830NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3350659117830NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3350660117830NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3350661117830NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3350662117830NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3350663117830NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3350664117830NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3350665117830NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3350666117830NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3350667117830NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3350668117830NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3350669117830NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3350670117830NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3350671117830NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsKadabagere-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350672117831NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3350673117831NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3350674117831NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3350675117831NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3350676117831NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3350677117831NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3350678117831NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3350679117831NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3350680117831NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3350681117831NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3350682117831NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3350683117831NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3350684117831NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3350685117831NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3350686117831NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3350687117831NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3350688117831NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3350689117831NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3350690117831NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3350691117831NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3350692117831NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3350693117831NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3350694117831NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3350695117831NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3350696117831NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3350697117831NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3350698117831NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3350699117831NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3350700117831NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3350701117831NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3350702117831NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3350703117831NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3350704117831NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3350705117831NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3350706117831NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3350707117831NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3350708117831NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3350709117831NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3350710117831NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3350711117831NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3350712117831NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3350713117831NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3350714117831NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3350715117831NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3350716117831NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3350717117831NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3350718117831NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3350719117831NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3350720117831NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3350721117831NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3350722117831NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3350723117831NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3350724117831NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3350725117831NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3350726117831NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3350727117831NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3350728117831NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3350729117831NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsKadabagere-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350730117832NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3350731117832NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3350732117832NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350733117832NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3350734117832NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3350735117832NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3350736117832NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3350737117832NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3350738117832NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3350739117832NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350740117832NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350741117832NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3350742117832NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsKadabagere-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350743117833NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3350744117833NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3350745117833NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350746117833NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3350747117833NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3350748117833NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3350749117833NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3350750117833NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3350751117833NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350752117833NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350753117833NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsMadiagere-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350754117834NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3350755117834NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3350756117834NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3350757117834NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3350758117834NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3350759117834NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3350760117834NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3350761117834NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3350762117834NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3350763117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3350764117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3350765117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3350766117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3350767117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3350768117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3350769117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3350770117834NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3350771117834NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3350772117834NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3350773117834NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3350774117834NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3350775117834NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3350776117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3350777117834NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3350778117834NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3350779117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3350780117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3350781117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3350782117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3350783117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3350784117834NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3350785117834NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3350786117834NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3350787117834NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3350788117834NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3350789117834NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3350790117834NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3350791117834NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3350792117834NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3350793117834NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3350794117834NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3350795117834NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3350796117834NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3350797117834NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3350798117834NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3350799117834NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3350800117834NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3350801117834NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3350802117834NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3350803117834NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3350804117834NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3350805117834NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3350806117834NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3350807117834NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3350808117834NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsMadiagere-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350809117835NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3350810117835NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3350811117835NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3350812117835NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3350813117835NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3350814117835NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3350815117835NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3350816117835NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3350817117835NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3350818117835NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3350819117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3350820117835NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3350821117835NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3350822117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3350823117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3350824117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3350825117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3350826117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3350827117835NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3350828117835NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3350829117835NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3350830117835NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3350831117835NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3350832117835NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3350833117835NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3350834117835NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3350835117835NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3350836117835NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3350837117835NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3350838117835NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3350839117835NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3350840117835NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3350841117835NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3350842117835NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3350843117835NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3350844117835NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3350845117835NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3350846117835NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3350847117835NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3350848117835NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3350849117835NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3350850117835NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3350851117835NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3350852117835NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3350853117835NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsMadiagere-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350854117836NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3350855117836NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3350856117836NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3350857117836NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3350858117836NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3350859117836NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3350860117836NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3350861117836NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3350862117836NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3350863117836NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3350864117836NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3350865117836NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3350866117836NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3350867117836NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3350868117836NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3350869117836NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3350870117836NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3350871117836NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3350872117836NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3350873117836NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3350874117836NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsMadiagere-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350875117837NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3350876117837NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3350877117837NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3350878117837NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3350879117837NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3350880117837NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3350881117837NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3350882117837NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3350883117837NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3350884117837NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3350885117837NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3350886117837NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3350887117837NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3350888117837NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3350889117837NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3350890117837NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3350891117837NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3350892117837NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3350893117837NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3350894117837NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3350895117837NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3350896117837NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3350897117837NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3350898117837NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3350899117837NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3350900117837NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3350901117837NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3350902117837NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3350903117837NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3350904117837NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3350905117837NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3350906117837NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3350907117837NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3350908117837NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3350909117837NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3350910117837NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3350911117837NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3350912117837NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3350913117837NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3350914117837NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3350915117837NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3350916117837NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3350917117837NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3350918117837NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3350919117837NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3350920117837NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3350921117837NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3350922117837NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3350923117837NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3350924117837NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3350925117837NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3350926117837NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3350927117837NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3350928117837NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3350929117837NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3350930117837NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3350931117837NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3350932117837NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsMadiagere-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350933117838NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3350934117838NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3350935117838NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350936117838NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3350937117838NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3350938117838NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3350939117838NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3350940117838NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3350941117838NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3350942117838NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350943117838NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350944117838NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3350945117838NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsMadiagere-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350946117839NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3350947117839NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3350948117839NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3350949117839NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3350950117839NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3350951117839NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3350952117839NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3350953117839NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3350954117839NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3350955117839NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3350956117839NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsMalavi-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3350957117840NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3350958117840NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3350959117840NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3350960117840NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3350961117840NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3350962117840NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3350963117840NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3350964117840NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3350965117840NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3350966117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3350967117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3350968117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3350969117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3350970117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3350971117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3350972117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3350973117840NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3350974117840NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3350975117840NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3350976117840NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3350977117840NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3350978117840NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3350979117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3350980117840NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3350981117840NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3350982117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3350983117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3350984117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3350985117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3350986117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3350987117840NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3350988117840NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3350989117840NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3350990117840NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3350991117840NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3350992117840NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3350993117840NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3350994117840NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3350995117840NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3350996117840NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3350997117840NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3350998117840NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3350999117840NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3351000117840NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3351001117840NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3351002117840NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3351003117840NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3351004117840NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3351005117840NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3351006117840NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3351007117840NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3351008117840NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3351009117840NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3351010117840NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3351011117840NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsMalavi-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351012117841NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3351013117841NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3351014117841NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3351015117841NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3351016117841NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3351017117841NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3351018117841NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3351019117841NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3351020117841NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3351021117841NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3351022117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3351023117841NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3351024117841NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3351025117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3351026117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3351027117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3351028117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3351029117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3351030117841NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3351031117841NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3351032117841NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3351033117841NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3351034117841NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3351035117841NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3351036117841NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3351037117841NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3351038117841NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3351039117841NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3351040117841NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3351041117841NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3351042117841NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3351043117841NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3351044117841NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3351045117841NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3351046117841NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3351047117841NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3351048117841NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3351049117841NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3351050117841NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3351051117841NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3351052117841NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3351053117841NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3351054117841NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3351055117841NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3351056117841NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsMalavi-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351057117842NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3351058117842NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3351059117842NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3351060117842NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3351061117842NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3351062117842NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3351063117842NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3351064117842NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3351065117842NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3351066117842NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3351067117842NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3351068117842NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3351069117842NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3351070117842NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3351071117842NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3351072117842NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3351073117842NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3351074117842NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3351075117842NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3351076117842NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3351077117842NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsMalavi-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351078117843NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3351079117843NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3351080117843NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3351081117843NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3351082117843NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3351083117843NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3351084117843NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3351085117843NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3351086117843NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3351087117843NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3351088117843NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3351089117843NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3351090117843NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3351091117843NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3351092117843NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3351093117843NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3351094117843NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3351095117843NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3351096117843NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3351097117843NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3351098117843NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3351099117843NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3351100117843NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3351101117843NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3351102117843NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3351103117843NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3351104117843NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3351105117843NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3351106117843NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3351107117843NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3351108117843NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3351109117843NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3351110117843NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3351111117843NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3351112117843NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3351113117843NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3351114117843NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3351115117843NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3351116117843NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3351117117843NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3351118117843NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3351119117843NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3351120117843NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3351121117843NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3351122117843NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3351123117843NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3351124117843NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3351125117843NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3351126117843NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3351127117843NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3351128117843NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3351129117843NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3351130117843NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3351131117843NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3351132117843NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3351133117843NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3351134117843NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3351135117843NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsMalavi-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351136117844NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3351137117844NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3351138117844NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351139117844NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3351140117844NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3351141117844NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3351142117844NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3351143117844NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3351144117844NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3351145117844NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351146117844NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351147117844NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3351148117844NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsMalavi-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351149117845NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3351150117845NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3351151117845NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351152117845NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3351153117845NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3351154117845NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3351155117845NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3351156117845NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3351157117845NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351158117845NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351159117845NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsBannigolu-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351160117846NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3351161117846NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3351162117846NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3351163117846NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3351164117846NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3351165117846NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3351166117846NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3351167117846NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3351168117846NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3351169117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3351170117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3351171117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3351172117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3351173117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3351174117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3351175117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3351176117846NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3351177117846NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3351178117846NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3351179117846NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3351180117846NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3351181117846NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3351182117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3351183117846NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3351184117846NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3351185117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3351186117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3351187117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3351188117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3351189117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3351190117846NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3351191117846NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3351192117846NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3351193117846NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3351194117846NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3351195117846NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3351196117846NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3351197117846NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3351198117846NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3351199117846NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3351200117846NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3351201117846NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3351202117846NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3351203117846NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3351204117846NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3351205117846NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3351206117846NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3351207117846NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3351208117846NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3351209117846NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3351210117846NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3351211117846NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3351212117846NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3351213117846NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3351214117846NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsBannigolu-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351215117847NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3351216117847NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3351217117847NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3351218117847NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3351219117847NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3351220117847NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3351221117847NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3351222117847NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3351223117847NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3351224117847NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3351225117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3351226117847NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3351227117847NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3351228117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3351229117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3351230117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3351231117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3351232117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3351233117847NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3351234117847NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3351235117847NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3351236117847NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3351237117847NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3351238117847NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3351239117847NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3351240117847NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3351241117847NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3351242117847NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3351243117847NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3351244117847NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3351245117847NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3351246117847NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3351247117847NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3351248117847NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3351249117847NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3351250117847NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3351251117847NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3351252117847NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3351253117847NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3351254117847NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3351255117847NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3351256117847NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3351257117847NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3351258117847NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3351259117847NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsBannigolu-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351260117848NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3351261117848NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3351262117848NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3351263117848NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3351264117848NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3351265117848NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3351266117848NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3351267117848NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3351268117848NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3351269117848NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3351270117848NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3351271117848NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3351272117848NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3351273117848NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3351274117848NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3351275117848NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3351276117848NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3351277117848NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3351278117848NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3351279117848NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3351280117848NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsBannigolu-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351281117849NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3351282117849NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3351283117849NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3351284117849NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3351285117849NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3351286117849NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3351287117849NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3351288117849NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3351289117849NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3351290117849NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3351291117849NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3351292117849NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3351293117849NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3351294117849NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3351295117849NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3351296117849NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3351297117849NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3351298117849NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3351299117849NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3351300117849NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3351301117849NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3351302117849NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3351303117849NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3351304117849NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3351305117849NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3351306117849NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3351307117849NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3351308117849NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3351309117849NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3351310117849NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3351311117849NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3351312117849NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3351313117849NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3351314117849NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3351315117849NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3351316117849NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3351317117849NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3351318117849NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3351319117849NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3351320117849NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3351321117849NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3351322117849NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3351323117849NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3351324117849NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3351325117849NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3351326117849NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3351327117849NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3351328117849NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3351329117849NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3351330117849NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3351331117849NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3351332117849NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3351333117849NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3351334117849NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3351335117849NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3351336117849NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3351337117849NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3351338117849NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsBannigolu-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351339117850NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3351340117850NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3351341117850NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351342117850NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3351343117850NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3351344117850NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3351345117850NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3351346117850NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3351347117850NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3351348117850NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351349117850NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351350117850NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3351351117850NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsBannigolu-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351352117851NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3351353117851NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3351354117851NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351355117851NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3351356117851NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3351357117851NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3351358117851NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3351359117851NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3351360117851NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351361117851NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351362117851NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsMutkuru-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351363117852NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3351364117852NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3351365117852NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3351366117852NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3351367117852NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3351368117852NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3351369117852NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3351370117852NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3351371117852NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3351372117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3351373117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3351374117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3351375117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3351376117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3351377117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3351378117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3351379117852NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3351380117852NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3351381117852NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3351382117852NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3351383117852NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3351384117852NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3351385117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3351386117852NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3351387117852NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3351388117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3351389117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3351390117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3351391117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3351392117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3351393117852NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3351394117852NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3351395117852NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3351396117852NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3351397117852NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3351398117852NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3351399117852NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3351400117852NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3351401117852NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3351402117852NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3351403117852NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3351404117852NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3351405117852NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3351406117852NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3351407117852NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3351408117852NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3351409117852NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3351410117852NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3351411117852NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3351412117852NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3351413117852NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3351414117852NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3351415117852NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3351416117852NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3351417117852NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsMutkuru-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351418117853NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3351419117853NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3351420117853NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3351421117853NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3351422117853NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3351423117853NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3351424117853NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3351425117853NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3351426117853NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3351427117853NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3351428117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3351429117853NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3351430117853NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3351431117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3351432117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3351433117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3351434117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3351435117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3351436117853NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3351437117853NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3351438117853NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3351439117853NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3351440117853NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3351441117853NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3351442117853NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3351443117853NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3351444117853NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3351445117853NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3351446117853NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3351447117853NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3351448117853NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3351449117853NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3351450117853NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3351451117853NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3351452117853NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3351453117853NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3351454117853NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3351455117853NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3351456117853NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3351457117853NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3351458117853NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3351459117853NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3351460117853NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3351461117853NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3351462117853NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsMutkuru-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351463117854NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3351464117854NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3351465117854NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3351466117854NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3351467117854NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3351468117854NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3351469117854NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3351470117854NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3351471117854NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3351472117854NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3351473117854NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3351474117854NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3351475117854NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3351476117854NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3351477117854NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3351478117854NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3351479117854NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3351480117854NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3351481117854NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3351482117854NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3351483117854NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsMutkuru-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351484117855NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3351485117855NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3351486117855NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3351487117855NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3351488117855NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3351489117855NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3351490117855NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3351491117855NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3351492117855NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3351493117855NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3351494117855NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3351495117855NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3351496117855NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3351497117855NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3351498117855NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3351499117855NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3351500117855NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3351501117855NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3351502117855NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3351503117855NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3351504117855NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3351505117855NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3351506117855NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3351507117855NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3351508117855NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3351509117855NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3351510117855NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3351511117855NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3351512117855NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3351513117855NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3351514117855NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3351515117855NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3351516117855NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3351517117855NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3351518117855NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3351519117855NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3351520117855NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3351521117855NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3351522117855NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3351523117855NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3351524117855NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3351525117855NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3351526117855NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3351527117855NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3351528117855NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3351529117855NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3351530117855NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3351531117855NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3351532117855NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3351533117855NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3351534117855NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3351535117855NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3351536117855NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3351537117855NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3351538117855NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3351539117855NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3351540117855NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3351541117855NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsMutkuru-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351542117856NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3351543117856NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3351544117856NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351545117856NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3351546117856NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3351547117856NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3351548117856NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3351549117856NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3351550117856NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3351551117856NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351552117856NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351553117856NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3351554117856NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsMutkuru-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351555117857NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3351556117857NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3351557117857NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351558117857NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3351559117857NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3351560117857NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3351561117857NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3351562117857NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3351563117857NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351564117857NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351565117857NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsMorba-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351566117858NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3351567117858NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3351568117858NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3351569117858NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3351570117858NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3351571117858NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3351572117858NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3351573117858NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3351574117858NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3351575117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3351576117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3351577117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3351578117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3351579117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3351580117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3351581117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3351582117858NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3351583117858NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3351584117858NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3351585117858NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3351586117858NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3351587117858NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3351588117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3351589117858NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3351590117858NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3351591117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3351592117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3351593117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3351594117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3351595117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3351596117858NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3351597117858NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3351598117858NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3351599117858NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3351600117858NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3351601117858NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3351602117858NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3351603117858NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3351604117858NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3351605117858NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3351606117858NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3351607117858NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3351608117858NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3351609117858NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3351610117858NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3351611117858NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3351612117858NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3351613117858NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3351614117858NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3351615117858NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3351616117858NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3351617117858NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3351618117858NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3351619117858NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3351620117858NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsMorba-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351621117859NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3351622117859NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3351623117859NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3351624117859NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3351625117859NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3351626117859NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3351627117859NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3351628117859NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3351629117859NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3351630117859NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3351631117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3351632117859NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3351633117859NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3351634117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3351635117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3351636117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3351637117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3351638117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3351639117859NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3351640117859NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3351641117859NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3351642117859NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3351643117859NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3351644117859NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3351645117859NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3351646117859NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3351647117859NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3351648117859NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3351649117859NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3351650117859NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3351651117859NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3351652117859NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3351653117859NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3351654117859NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3351655117859NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3351656117859NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3351657117859NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3351658117859NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3351659117859NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3351660117859NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3351661117859NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3351662117859NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3351663117859NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3351664117859NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3351665117859NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsMorba-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351666117860NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3351667117860NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3351668117860NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3351669117860NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3351670117860NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3351671117860NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3351672117860NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3351673117860NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3351674117860NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3351675117860NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3351676117860NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3351677117860NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3351678117860NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3351679117860NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3351680117860NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3351681117860NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3351682117860NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3351683117860NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3351684117860NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3351685117860NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3351686117860NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsMorba-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351687117861NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3351688117861NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3351689117861NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3351690117861NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3351691117861NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3351692117861NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3351693117861NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3351694117861NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3351695117861NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3351696117861NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3351697117861NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3351698117861NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3351699117861NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3351700117861NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3351701117861NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3351702117861NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3351703117861NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3351704117861NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3351705117861NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3351706117861NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3351707117861NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3351708117861NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3351709117861NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3351710117861NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3351711117861NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3351712117861NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3351713117861NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3351714117861NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3351715117861NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3351716117861NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3351717117861NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3351718117861NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3351719117861NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3351720117861NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3351721117861NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3351722117861NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3351723117861NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3351724117861NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3351725117861NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3351726117861NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3351727117861NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3351728117861NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3351729117861NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3351730117861NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3351731117861NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3351732117861NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3351733117861NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3351734117861NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3351735117861NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3351736117861NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3351737117861NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3351738117861NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3351739117861NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3351740117861NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3351741117861NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3351742117861NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3351743117861NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3351744117861NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsMoraba-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351745117862NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3351746117862NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3351747117862NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351748117862NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3351749117862NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3351750117862NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3351751117862NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3351752117862NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3351753117862NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3351754117862NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351755117862NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351756117862NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3351757117862NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsMoraba-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351758117863NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3351759117863NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3351760117863NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351761117863NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3351762117863NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3351763117863NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3351764117863NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3351765117863NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3351766117863NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351767117863NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351768117863NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsHegdalu-Ground Floor3552042.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351769117864NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3351770117864NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3351771117864NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3351772117864NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3351773117864NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3351774117864NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3351775117864NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3351776117864NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3351777117864NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3351778117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3351779117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3351780117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3351781117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3351782117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3351783117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3351784117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3351785117864NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3351786117864NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3351787117864NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3351788117864NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3351789117864NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3351790117864NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3351791117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3351792117864NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3351793117864NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3351794117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3351795117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3351796117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3351797117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3351798117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3351799117864NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3351800117864NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3351801117864NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3351802117864NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3351803117864NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3351804117864NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3351805117864NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3351806117864NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3351807117864NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3351808117864NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3351809117864NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3351810117864NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3351811117864NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3351812117864NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3351813117864NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.3631.52FalseNoneNoneFalseNoneFalse106076.14720
3351814117864NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3351815117864NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3351816117864NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3351817117864NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3351818117864NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3351819117864NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3351820117864NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3351821117864NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3351822117864NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3351823117864NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsHegdalu-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351824117865NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3351825117865NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3351826117865NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3351827117865NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3351828117865NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3351829117865NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3351830117865NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3351831117865NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3351832117865NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3351833117865NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3351834117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3351835117865NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3351836117865NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3351837117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3351838117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3351839117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3351840117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3351841117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3351842117865NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3351843117865NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3351844117865NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3351845117865NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3351846117865NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3351847117865NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3351848117865NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3351849117865NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3351850117865NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3351851117865NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3351852117865NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3351853117865NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3351854117865NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3351855117865NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3351856117865NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3351857117865NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3351858117865NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3351859117865NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3351860117865NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3351861117865NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3351862117865NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3351863117865NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3351864117865NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3351865117865NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3351866117865NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3351867117865NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3351868117865NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsHegdalu-Water Suppy and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351869117866NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3351870117866NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3351871117866NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3351872117866NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3351873117866NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3351874117866NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3351875117866NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3351876117866NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3351877117866NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3351878117866NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3351879117866NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3351880117866NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3351881117866NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3351882117866NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3351883117866NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3351884117866NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3351885117866NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3351886117866NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3351887117866NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3351888117866NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3351889117866NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsHegdalu-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351890117867NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3351891117867NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3351892117867NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3351893117867NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3351894117867NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3351895117867NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3351896117867NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3351897117867NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3351898117867NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3351899117867NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3351900117867NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3351901117867NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3351902117867NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3351903117867NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3351904117867NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3351905117867NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3351906117867NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3351907117867NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3351908117867NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3351909117867NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3351910117867NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3351911117867NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3351912117867NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3351913117867NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3351914117867NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3351915117867NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3351916117867NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3351917117867NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3351918117867NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3351919117867NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3351920117867NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3351921117867NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3351922117867NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3351923117867NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3351924117867NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3351925117867NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3351926117867NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3351927117867NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3351928117867NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3351929117867NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3351930117867NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3351931117867NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3351932117867NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3351933117867NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3351934117867NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3351935117867NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3351936117867NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3351937117867NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3351938117867NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3351939117867NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3351940117867NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3351941117867NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3351942117867NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3351943117867NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3351944117867NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3351945117867NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3351946117867NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3351947117867NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsHegdalu-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351948117868NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3351949117868NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3351950117868NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351951117868NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3351952117868NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3351953117868NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3351954117868NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3351955117868NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3351956117868NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3351957117868NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351958117868NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351959117868NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3351960117868NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsHegdalu-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351961117869NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3351962117869NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3351963117869NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3351964117869NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3351965117869NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3351966117869NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3351967117869NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3351968117869NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3351969117869NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3351970117869NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3351971117869NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsDananayakannakere-Ground Floor3468715.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3351972117870NonePWD V- 3 SR 2023-24 Page No-7 It No-2.4 (II) BClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposalof unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means100 Sqm1858.51858.52.12FalseNoneNoneFalseNoneFalse3940.020
3351973117870NonePWD V- 2 SR 2023-24 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7142.38FalseNoneNoneFalseNoneFalse4988.54980
3351974117870NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.84133.61FalseNoneNoneFalseNoneFalse40061.62240
3351975117870NonePWD V- 1 SR 2023-24 Page No-6 It No-1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4633.4FalseNoneNoneFalseNoneFalse12373.3640
3351976117870NonePWD V- 2 SR 2023-24 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2104.26FalseNoneNoneFalseNoneFalse15242.8120
3351977117870NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57133.61FalseNoneNoneFalseNoneFalse44033.84770
3351978117870NonePWD V- 1 SR 2023-24 Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.2962.58FalseNoneNoneFalseNoneFalse36752.60820
3351979117870NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.022.16FalseNoneNoneFalseNoneFalse147275.360
3351980117870NonePWD V- 1 SR 2023-24 Page No-15 It No-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7630.77FalseNoneNoneFalseNoneFalse258860.62520
3351981117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to PlinthCum13318.1313318.132.03FalseNoneNoneFalseNoneFalse27035.80390
3351982117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , PLINTH BEAMCum11751.311751.311.73FalseNoneNoneFalseNoneFalse137842.7490
3351983117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum13964.7713964.774.78FalseNoneNoneFalseNoneFalse66751.60060
3351984117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13143.3113143.315.19FalseNoneNoneFalseNoneFalse68213.77890
3351985117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12321.8612321.8615.8FalseNoneNoneFalseNoneFalse194685.3880
3351986117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC STAIRCASECum12321.8612321.862.95FalseNoneNoneFalseNoneFalse36349.4870
3351987117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13143.3113143.312.65FalseNoneNoneFalseNoneFalse34829.77150
3351988117870NonePWD V- 1 SR 2023-24 Page No-16 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11911.1311911.130.61FalseNoneNoneFalseNoneFalse7265.78930
3351989117870NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum12324.5812324.583.58FalseNoneNoneFalseNoneFalse44121.99640
3351990117870NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.226.61FalseNoneNoneFalseNoneFalse732634.02420
3351991117870NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.5949.27FalseNoneNoneFalseNoneFalse486471.77930
3351992117870NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.3437.58FalseNoneNoneFalseNoneFalse49355.31720
3351993117870NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.4FalseNoneNoneFalseNoneFalse48972.7160
3351994117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4327.834327.8311.34FalseNoneNoneFalseNoneFalse49077.59220
3351995117870NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm869.78869.7824.0FalseNoneNoneFalseNoneFalse20874.720
3351996117870NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4317.924317.926.3FalseNoneNoneFalseNoneFalse27202.8960
3351997117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.826.0FalseNoneNoneFalseNoneFalse7552.920
3351998117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.431303.436.0FalseNoneNoneFalseNoneFalse7820.580
3351999117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.616.0FalseNoneNoneFalseNoneFalse7359.660
3352000117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6412.0FalseNoneNoneFalseNoneFalse3523.680
3352001117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3352002117870NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3352003117870NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7312.0FalseNoneNoneFalseNoneFalse4088.760
3352004117870NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3436.0FalseNoneNoneFalseNoneFalse2676.240
3352005117870NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.0452.0435.4FalseNoneNoneFalseNoneFalse1842.2160
3352006117870NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg208.15208.15232.47FalseNoneNoneFalseNoneFalse48388.63050
3352007117870NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6910.35FalseNoneNoneFalseNoneFalse84007.74150
3352008117870NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3352009117870NonePWD V- 2 SR 2023-24 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.4392.87FalseNoneNoneFalseNoneFalse24279.00410
3352010117870NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm315.95315.95330.84FalseNoneNoneFalseNoneFalse104528.8980
3352011117870NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm386.57386.5738.43FalseNoneNoneFalseNoneFalse14855.88510
3352012117870NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.68225.61FalseNoneNoneFalseNoneFalse77988.86480
3352013117870NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem54.5254.52408.6FalseNoneNoneFalseNoneFalse22276.8720
3352014117870NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m64.4364.43238.64FalseNoneNoneFalseNoneFalse15375.57520
3352015117870NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1418.661418.6672.88FalseNoneNoneFalseNoneFalse103391.94080
3352016117870NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,Lakared, River Pink,Orissa Blue or equivalent.Sqm3365.363365.366.76FalseNoneNoneFalseNoneFalse22749.83360
3352017117870NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1333.161333.167.2FalseNoneNoneFalseNoneFalse9598.7520
3352018117870NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1795.311795.3138.43FalseNoneNoneFalseNoneFalse68993.76330
3352019117870NonePWD V- 2 SR 2021-22 Page No-83 It No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs700.04700.0494.5FalseNoneNoneFalseNoneFalse66153.780
3352020117870NonePWD V- 2 SR 2023-24 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.9423.71FalseNoneNoneFalseNoneFalse52497.6690
3352021117870NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm157.35157.35423.71FalseNoneNoneFalseNoneFalse66670.76850
3352022117870NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28225.61FalseNoneNoneFalseNoneFalse43605.90080
3352023117870NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.5411.07FalseNoneNoneFalseNoneFalse692.31780
3352024117870NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.8411.07FalseNoneNoneFalseNoneFalse1592.30880
3352025117870NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6727.22FalseNoneNoneFalseNoneFalse1787.53740
3352026117870NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm49.5649.5627.22FalseNoneNoneFalseNoneFalse1349.02320
17193159450000NoneNoneBuildingsDananayakannakere-First Floor2102796.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352027117871NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNSCum14043.014043.05.06FalseNoneNoneFalseNoneFalse71057.580
3352028117871NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC BEAMSCum13221.5513221.555.0FalseNoneNoneFalseNoneFalse66107.750
3352029117871NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, RCC SLABCum12400.0912400.0913.56FalseNoneNoneFalseNoneFalse168145.22040
3352030117871NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, LINTELSCum13221.5513221.551.91FalseNoneNoneFalseNoneFalse25253.16050
3352031117871NonePWD V- 1 SR 2023-24 Page No-17 It No-2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ChejjaCum11989.3611989.360.63FalseNoneNoneFalseNoneFalse7553.29680
3352032117871NonePWD V- 2 SR 2023-24 Page No-15 It No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum9243.449243.449.87FalseNoneNoneFalseNoneFalse91232.75280
3352033117871NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst111892.82111892.822.84FalseNoneNoneFalseNoneFalse317775.60880
3352034117871NonePWD V- 2 SR 2023-24 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9967.639967.6335.58FalseNoneNoneFalseNoneFalse354648.27540
3352035117871NonePWD V- 2 SR 2023-24 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1325.851325.8541.21FalseNoneNoneFalseNoneFalse54638.27850
3352036117871NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum123597.8123597.80.33FalseNoneNoneFalseNoneFalse40787.2740
3352037117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercialSqm4369.044369.049.42FalseNoneNoneFalseNoneFalse41156.35680
3352038117871NonePWD V- 2 SR 2023-24 Page No-111 It No-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm878.06878.0612.0FalseNoneNoneFalseNoneFalse10536.720
3352039117871NonePWD V- 2 SR 2023-24 Page No-112 It No-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3352040117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1270.811270.815.0FalseNoneNoneFalseNoneFalse6354.050
3352041117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1315.841315.845.0FalseNoneNoneFalseNoneFalse6579.20
3352042117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1238.291238.297.0FalseNoneNoneFalseNoneFalse8668.030
3352043117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos296.44296.4412.0FalseNoneNoneFalseNoneFalse3557.280
3352044117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos162.6162.612.0FalseNoneNoneFalseNoneFalse1951.20
3352045117871NonePWD V- 2 SR 2023-24 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.7968.7910.0FalseNoneNoneFalseNoneFalse687.90
3352046117871NonePWD V- 2 SR 2023-24 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos343.97343.9714.0FalseNoneNoneFalseNoneFalse4815.580
3352047117871NonePWD V- 2 SR 2023-24 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos75.0575.0534.0FalseNoneNoneFalseNoneFalse2551.70
3352048117871NonePWD V- 2 SR 2023-24 Page No-205 It No-20.80Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications.m52.5352.5323.0FalseNoneNoneFalseNoneFalse1208.190
3352049117871NonePWD V- 2 SR 2023-24 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg210.13210.13163.62FalseNoneNoneFalseNoneFalse34381.47060
3352050117871NonePWD V- 2 SR 2023-24 Page No-110 It No-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8193.998193.998.37FalseNoneNoneFalseNoneFalse68583.69630
3352051117871NonePWD V- 2 SR 2023-24 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3352052117871NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.16326.1687.99FalseNoneNoneFalseNoneFalse28698.81840
3352053117871NonePWD V- 2 SR 2023-24 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm318.95318.95297.92FalseNoneNoneFalseNoneFalse95021.5840
3352054117871NonePWD V- 2 SR 2023-24 Page No-41 It No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm390.25390.2532.02FalseNoneNoneFalseNoneFalse12495.8050
3352055117871NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm348.97348.97233.86FalseNoneNoneFalseNoneFalse81610.12420
3352056117871NonePWD V- 2 SR 2023-24 Page No-43 It No-8.16.3Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm widem55.0455.04268.8FalseNoneNoneFalseNoneFalse14794.7520
3352057117871NonePWD V- 2 SR 2023-24 Page No-54 It No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m65.0465.04171.55FalseNoneNoneFalseNoneFalse11157.6120
3352058117871NonePWD V- 2 SR 2021-22 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1432.171432.1755.67FalseNoneNoneFalseNoneFalse79728.90390
3352059117871NonePWD V- 2 SR 2023-24 Page No-60 It No-9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includingpointing the joints with white cement and matching pigment etc.,complete.Sqm1345.861345.865.98FalseNoneNoneFalseNoneFalse8048.24280
3352060117871NonePWD V- 2 SR 2023-24 Page No-9.39 It No-65Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.Sqm1812.411812.4132.02FalseNoneNoneFalseNoneFalse58033.36820
3352061117871NonePWD V- 2 SR 2023-24 Page No-63 It No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3567.283567.282.56FalseNoneNoneFalseNoneFalse9132.23680
3352062117871NonePWD V- 2 SR 2021-22 Page No-50 It No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm125.08125.08385.91FalseNoneNoneFalseNoneFalse48269.62280
3352063117871NonePWD V- 2 SR 2023-24 Page No-48 It No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm158.85158.85385.91FalseNoneNoneFalseNoneFalse61301.80350
3352064117871NonePWD V- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm195.12195.12233.86FalseNoneNoneFalseNoneFalse45630.76320
3352065117871NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm62.5462.549.09FalseNoneNoneFalseNoneFalse568.48860
3352066117871NonePWD V- 2 SR 2023-24 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm143.84143.849.09FalseNoneNoneFalseNoneFalse1307.50560
3352067117871NonePWD V- 2 SR 2023-24 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.2966.2922.6FalseNoneNoneFalseNoneFalse1498.1540
3352068117871NonePWD V- 2 SR 2023-24 Page No-48 It No-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm50.0350.0322.6FalseNoneNoneFalseNoneFalse1130.6780
3352069117871NonePWD V- 2 SR 2023-24 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm931.85931.85109.54FalseNoneNoneFalseNoneFalse102074.8490
3352070117871NonePWD V- 2 SR 2021-22 Page No-23 It No-7.18KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2522.862522.861.2FalseNoneNoneFalseNoneFalse3027.4320
3352071117871NoneMarket RateProviding consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- ---- - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Lump Sum for Each32153.7932153.791.0FalseNoneNoneFalseNoneFalse32153.790
17193159450000NoneNoneBuildingsDananayakannakere-Water Supply and Sanitation208859.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352072117872NonePWD V- 2 SR 2023-24 Page No-136 It No-14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm diam109.03109.0320.0FalseNoneNoneFalseNoneFalse2180.60
3352073117872NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0750.0FalseNoneNoneFalseNoneFalse17903.50
3352074117872NonePWD V- 2 SR 2023-24 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.02477.0240.0FalseNoneNoneFalseNoneFalse19080.80
3352075117872NonePWD V- 2 SR 2023-24 Page No-125 It No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm244.08244.0840.0FalseNoneNoneFalseNoneFalse9763.20
3352076117872NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3352077117872NonePWD V- 2 SR 2023-24 Page No-124 It No-13.44Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach428.69428.696.0FalseNoneNoneFalseNoneFalse2572.140
3352078117872NonePWD V- 2 SR 2023-24 Page No-136 It No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3352079117872NonePWD V- 2 SR 2023-24 Page No-123 It No-14.3.2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lidEach7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3352080117872NoneMARKET RATESupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2478.02478.01.0FalseNoneNoneFalseNoneFalse2478.00
3352081117872NonePWD V- 2 SR 2023-24 Page No-131 It No-14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach6051.286051.283.0FalseNoneNoneFalseNoneFalse18153.840
3352082117872NonePWD V- 2 SR 2023-24 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach5518.515518.511.0FalseNoneNoneFalseNoneFalse5518.510
3352083117872NonePWD V- 2 SR 2023-24 Page No-124 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos3173.083173.085.0FalseNoneNoneFalseNoneFalse15865.40
3352084117872NonePWD V- 2 SR 2021-22 Page No-133 It No-14.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mmNos6681.936681.931.0FalseNoneNoneFalseNoneFalse6681.930
3352085117872NonePWD V- 2 SR 2021-22 Page No-136 It No-14.27.2Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings : Size 600x450x200 mmNos4117.24117.21.0FalseNoneNoneFalseNoneFalse4117.20
3352086117872NonePWD V- 2 SR 2023-24 Page No-122 It No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm382.85382.8525.0FalseNoneNoneFalseNoneFalse9571.250
3352087117872NonePWD V- 2 SR 2023-24 Page No-122 It No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3352088117872NonePWD V- 2 SR 2023-24 Page No-115 It No-13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
3352089117872NonePWD V- 2 SR 2023-24 Page No-139 It No-14.55.aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNos1383.961383.964.0FalseNoneNoneFalseNoneFalse5535.840
3352090117872NonePWD V- 5 SR 2023-24 Page No-191 It No-16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5248.45248.45.0FalseNoneNoneFalseNoneFalse26242.00
3352091117872NonePWD V- 5 SR 2023-24 Page No-191 It No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3352092117872NonePWD V- 2 SR 2023-24 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
17193159450000NoneNoneBuildingsDananayakannakere-Electrification365206.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352093117873NonePWD SR V-6 Item No-2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switchPoint353.12353.1230.0FalseNoneNoneFalseNoneFalse10593.60
3352094117873NonePWD SR V-6 Item No-2.1.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint488.17488.1722.0FalseNoneNoneFalseNoneFalse10739.740
3352095117873NonePWD SR V-6 Item No-2.1.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint706.23706.2316.0FalseNoneNoneFalseNoneFalse11299.680
3352096117873NonePWD SR V-6 Item No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2WayEach170.98170.9821.0FalseNoneNoneFalseNoneFalse3590.580
3352097117873NonePWD SR V-6 Item No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5WayEach219.3219.36.0FalseNoneNoneFalseNoneFalse1315.80
3352098117873NonePWD SR V-6 Item No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6WayEach272.58272.582.0FalseNoneNoneFalseNoneFalse545.160
3352099117873NonePWD SR V-6 Item No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 WayEach323.38323.3813.0FalseNoneNoneFalseNoneFalse4203.940
3352100117873NonePWD SR V-6 Item No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12WayEach395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3352101117873NonePWD SR V-6 Item No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 1 to 2 ModuleEach169.74169.7421.0FalseNoneNoneFalseNoneFalse3564.540
3352102117873NonePWD SR V-6 Item No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach216.83216.836.0FalseNoneNoneFalseNoneFalse1300.980
3352103117873NonePWD SR V-6 Item No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach289.93289.932.0FalseNoneNoneFalseNoneFalse579.860
3352104117873NonePWD SR V-6 Item No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach351.88351.8813.0FalseNoneNoneFalseNoneFalse4574.440
3352105117873NonePWD SR V-6 Item No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach426.22426.224.0FalseNoneNoneFalseNoneFalse1704.880
3352106117873NonePWD SR V-6 Item No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach126.38126.38102.0FalseNoneNoneFalseNoneFalse12890.760
3352107117873NonePWD SR V-6 Item No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach211.87211.8737.0FalseNoneNoneFalseNoneFalse7839.190
3352108117873NonePWD SR V-6 Item No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3352109117873NonePWD SR V-6 Item No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3352110117873NonePWD SR V-6 Item No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach403.91403.916.0FalseNoneNoneFalseNoneFalse2423.460
3352111117873NonePWD SR V-6 Item No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach292.4292.417.0FalseNoneNoneFalseNoneFalse4970.80
3352112117873NonePWD SR V-6 Item No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong BellEach304.79304.792.0FalseNoneNoneFalseNoneFalse609.580
3352113117873NonePWD SR V-6 Item No-1.13Supplying And Fixing Metal Fan Box with Round Hook.No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3352114117873NonePWD SR V-6 Item No-1.2.1Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickm81.7781.7780.0FalseNoneNoneFalseNoneFalse6541.60
3352115117873NonePWD SR V-6 Item No-1.2.2Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickm96.6496.6450.0FalseNoneNoneFalseNoneFalse4832.00
3352116117873NonePWD SR V-6 Item No-1.1.1Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickm85.4985.4960.0FalseNoneNoneFalseNoneFalse5129.40
3352117117873NonePWD SR V-6 Item No-1.1.2Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickm100.36100.3630.0FalseNoneNoneFalseNoneFalse3010.80
3352118117873NonePWD SR V-6 Item No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2m32.2132.21125.0FalseNoneNoneFalseNoneFalse4026.250
3352119117873NonePWD SR V-6 Item No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2m52.0452.04200.0FalseNoneNoneFalseNoneFalse10408.00
3352120117873NonePWD SR V-6 Item No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2m78.0678.06100.0FalseNoneNoneFalseNoneFalse7806.00
3352121117873NonePWD SR V-6 Item No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Single Door 12 Way SP & NEach2308.262308.262.0FalseNoneNoneFalseNoneFalse4616.520
3352122117873NonePWD SR V-6 Item No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach514.19514.1920.0FalseNoneNoneFalseNoneFalse10283.80
3352123117873NonePWD SR V-6 Item No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3352124117873NonePWD SR V-6 Item No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each11466.9511466.952.0FalseNoneNoneFalseNoneFalse22933.90
3352125117873NonePWD SR V-6 Item No-5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 poleEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3352126117873NonePWD SR V-6 Item No-11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach682.69682.696.0FalseNoneNoneFalseNoneFalse4096.140
3352127117873NonePWD SR V-6 Item No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach854.91854.9129.0FalseNoneNoneFalseNoneFalse24792.390
3352128117873NonePWD SR V-6 Item No-11.11.3Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500KEach184.61184.612.0FalseNoneNoneFalseNoneFalse369.220
3352129117873NonePWD SR V-6 Item No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70WNo7424.097424.092.0FalseNoneNoneFalseNoneFalse14848.180
3352130117873NonePWD SR V-6 Item No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1848.591848.594.0FalseNoneNoneFalseNoneFalse7394.360
3352131117873NonePWD SR V-6 Item No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3697.183697.1811.0FalseNoneNoneFalseNoneFalse40668.980
3352132117873NonePWD SR V-6 Item No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 PinEach78.0678.0619.0FalseNoneNoneFalseNoneFalse1483.140
3352133117873NonePWD SR V-6 Item No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach151.16151.1637.0FalseNoneNoneFalseNoneFalse5592.920
3352134117873NonePWD SR V-6 Item No-13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each390.29390.2911.0FalseNoneNoneFalseNoneFalse4293.190
3352135117873NonePWD SR V-6 Item No-13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3352136117873NonePWD SR V-6 Item No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1810.181810.182.0FalseNoneNoneFalseNoneFalse3620.360
3352137117873NonePWD SR V-6 Item No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.72200.722.0FalseNoneNoneFalseNoneFalse401.440
3352138117873NonePWD V-6 It NO: 32.03 Page No: 131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.96146206.960.15FalseNoneNoneFalseNoneFalse21931.0440
3352139117873NonePWD V-6 It NO: 20.05 Page No: 52Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)Km1470.691470.690.15FalseNoneNoneFalseNoneFalse220.60350
3352140117873NonePWD V-6 It NO: 21.05 Page No: 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm25877.7525877.750.15FalseNoneNoneFalseNoneFalse3881.66250
3352141117873NonePWD V-6 It NO: 51.01 Page No: 22GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo920.58920.582.0FalseNoneNoneFalseNoneFalse1841.160
3352142117873NonePWD V-6 It NO: 51.02 Page No: 22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo837.56837.562.0FalseNoneNoneFalseNoneFalse1675.120
3352143117873NonePWD V-6 It NO: 51.03 Page No: 22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag384.09384.094.0FalseNoneNoneFalseNoneFalse1536.360
3352144117873NonePWD V-6 It NO: 1.6.2 Page No: 43Digging of Pit for providing GI Pipe type Earthing Hard SoilPer Pit3704.613704.612.0FalseNoneNoneFalseNoneFalse7409.220
3352145117873NonePWD SR V-6 Item No-5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWGSq CM0.620.6210000.0FalseNoneNoneFalseNoneFalse6200.00
3352146117873NonePWD SR V-6 Item No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm3054.143054.141.2FalseNoneNoneFalseNoneFalse3664.9680
3352147117873NonePWD SR V-6 Item No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm37.1737.172.4FalseNoneNoneFalseNoneFalse89.2080
3352148117873NonePWD SR V-6 Item No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm936.68936.682.4FalseNoneNoneFalseNoneFalse2248.0320
3352149117873NonePWD SR V-6 Item No-5.44.2Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mmEach7635.967635.961.0FalseNoneNoneFalseNoneFalse7635.960
3352150117873NonePWD SR V-6 Item No-5.31Supplying and fixing Electronic Trivector Meter(ETV)suitable For operation LT operationand-CT operatedmeterinpolycarbonatebodyinclass0.5accuracyasperIS14697andcompletely wired.Each5439.215439.212.0FalseNoneNoneFalseNoneFalse10878.420
17193159450000NoneNoneBuildingsDananayakannakere-Sump Tank129742.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352151117874NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.849.83FalseNoneNoneFalseNoneFalse2947.42720
3352152117874NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.62FalseNoneNoneFalseNoneFalse4120.520
3352153117874NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Bottom BedCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3352154117874NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, WallsCum11751.311751.31.89FalseNoneNoneFalseNoneFalse22209.9570
3352155117874NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, SlabCum11751.311751.30.57FalseNoneNoneFalseNoneFalse6698.2410
3352156117874NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.24FalseNoneNoneFalseNoneFalse26600.93280
3352157117874NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.574.86FalseNoneNoneFalseNoneFalse1601.71020
3352158117874NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6818.6FalseNoneNoneFalseNoneFalse6429.6480
3352159117874NonePWD V- 2 SR 2021-22 Page No-133 It No-15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Kgs923.06923.0637.08FalseNoneNoneFalseNoneFalse34227.06480
3352160117874NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3352161117874NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3352162117874NonePWD Bal Cir SR 2018-19 Page No-75 It No-11.45KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos314.71314.714.0FalseNoneNoneFalseNoneFalse1258.840
3352163117874NonePWD V- 5 SR 2023-24 Page No-149 It No-13.6.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 1.00 HP/0.75KW 7 STGNo15715.2415715.241.0FalseNoneNoneFalseNoneFalse15715.240
17193159450000NoneNoneBuildingsDananayakannakere-Septic Tank91752.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352164117875NonePWD V- 1 SR 2023-24 Page No-5 It No-1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum230.45230.4515.56FalseNoneNoneFalseNoneFalse3585.8020
3352165117875NonePWD V- 1 SR 2023-24 Page No-15 It No-2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6646.06646.00.72FalseNoneNoneFalseNoneFalse4785.120
3352166117875NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tankCum8460.938460.930.52FalseNoneNoneFalseNoneFalse4399.68360
3352167117875NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. WallsCum11751.311751.32.28FalseNoneNoneFalseNoneFalse26792.9640
3352168117875NonePWD V- 1 SR 2023-24 Page No-16 It No-2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SlabCum11751.311751.30.51FalseNoneNoneFalseNoneFalse5993.1630
3352169117875NonePWD V- 1 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.220.26FalseNoneNoneFalseNoneFalse28817.67720
3352170117875NonePWD V- 1 SR 2023-24 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.578.11FalseNoneNoneFalseNoneFalse2672.81270
3352171117875NonePWD V- 2 SR 2023-24 Page No-41 It No-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm345.68345.6822.2FalseNoneNoneFalseNoneFalse7674.0960
3352172117875NonePWD V- 2 SR 2023-24 Page No-112 It No-12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame.m796.68796.682.4FalseNoneNoneFalseNoneFalse1912.0320
3352173117875NonePWD V- 2 SR 2023-24 Page No-112 It No-12.97.2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 35 mm thicknessSqm4503.774503.770.36FalseNoneNoneFalseNoneFalse1621.35720
3352174117875NonePWD V- 2 SR 2023-24 Page No-127 It No-13.56Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design.Pit3497.73497.71.0FalseNoneNoneFalseNoneFalse3497.70
17193159450000NoneNoneBuildingsDananayakannakere-Demolition of Existing Building85831.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3352175117876NonePWD Volume- 2 SR 2023-24 Page No-187 It No-19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum3005.813005.8110.8FalseNoneNoneFalseNoneFalse32462.7480
3352176117876NonePWD Volume- 2 SR 2023-24 Page No-187 It No-19.7.1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum597.2597.221.9FalseNoneNoneFalseNoneFalse13078.680
3352177117876NonePWD Volume- 1 SR 2023-24 Page No-187 It No-19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. In cement mortarCum2086.482086.4819.31FalseNoneNoneFalseNoneFalse40289.92880
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17193159460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17193159460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17193159460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17193159460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17193159460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17193159570000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17193159630000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17193159680000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17193159730000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17193159780000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17193159830000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17193159950000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17193160000000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17193160050000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17193160110000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17193160160000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17193160270000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17193160340000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17193160390000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17193160460000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17193160520000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17193160570000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17193160620000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17193160680000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17193160730000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1162.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.290.30 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 2141.00 Cum 2.PCC & RCC 1051.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 71.64 Tonnes 4.BBM/Concrete Blocks 611.00 Cum. 5. Flooring (Vitrified/Granite/Ceramic) 1595.00 Sqm 6. Plastering 9960.00 Sqm 7. Painting 10065.00 Sqm 8. MS Grill 2852.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.16.44 Lakhs in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.9.40 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass I PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished SlNo. Description of Key items of Works. Quantity1.Excavator/JCB 1 No 2.Transit mixer/Concrete mixer 2 Nos 3.Needle vibrator with size not less than 20mm 3 Nos 4.Tipper 1 No 5.Generator 250 KVA 1 No 6. Truck Mounted Water Tanker 1 No Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 6 months .Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 5 years in the Construction of buildings OR Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.174.20 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719316452000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone