3350235 | 117816 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11834.55 | 11834.55 | 1.61 | False | None | None | False | None | False | 19053.6255 | 0 |
3350236 | 117816 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 4.45 | False | None | None | False | None | False | 49565.88 | 0 |
3350237 | 117816 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 8.62 | False | None | None | False | None | False | 90012.195 | 0 |
3350238 | 117816 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10094.18 | 10094.18 | 0.41 | False | None | None | False | None | False | 4138.6138 | 0 |
3350239 | 117816 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8621.55 | 8621.55 | 11.12 | False | None | None | False | None | False | 95871.636 | 0 |
3350240 | 117816 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 93929.85 | 93929.85 | 1.2 | False | None | None | False | None | False | 112715.82 | 0 |
3350241 | 117816 | None | 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4701.9 | 4701.9 | 2.52 | False | None | None | False | None | False | 11848.788 | 0 |
3350242 | 117816 | None | 11.15.1 | Providing and fixing M.S. Tubular frames for doors, windows,
ventilators and cupboard with rectangular/ L-Type sections, made of
1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with
profiles of required size, including fixing of necessary butt hinges and
screws and applying a priming coat of approved steel primer: Fixing
with 15x3 mm lugs 10 cm long embedded in cement concrete block
15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Sqm | 134.4 | 134.4 | 151.2 | False | None | None | False | None | False | 20321.28 | 0 |
3350243 | 117816 | None | 11.30.1 | Providing & fixing glass panes with putty and glazing clips in steel
doors, windows, clerestory windows, all complete with : 4.0 mm thick
glass panes including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in-
Charge. | Sqm | 957.6 | 957.6 | 4.32 | False | None | None | False | None | False | 4136.832 | 0 |
3350244 | 117816 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 176.4 | 176.4 | 305.24 | False | None | None | False | None | False | 53844.336 | 0 |
3350245 | 117816 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 384.3 | 384.3 | 155.82 | False | None | None | False | None | False | 59881.626 | 0 |
3350246 | 117816 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent | Sqm | 2994.6 | 2994.6 | 80.89 | False | None | None | False | None | False | 242233.194 | 0 |
3350247 | 117816 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 117.06 | False | None | None | False | None | False | 16839.081 | 0 |
3350248 | 117816 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 186.9 | 186.9 | 95.67 | False | None | None | False | None | False | 17880.723 | 0 |
3350249 | 117816 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 15.05 | False | None | None | False | None | False | 1817.2875 | 0 |
3350250 | 117816 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 105.0 | 105.0 | 95.67 | False | None | None | False | None | False | 10045.35 | 0 |
3350251 | 117816 | None | 12.2 | Providing and installing at site of work P.V.C. pipes including cost of pipes
and specials and labour, including lowering into trenches, laying true
to line, level and perfect linking at joints leak proof including jointing
of approved type with all labour charges and all lift charges, handling
charges including encasing the pipe around to a depth not less than
15 cms with gravel or selected earth available from the excavation etc.
complete. 4 Kg/m2: 75mm ( weight of pipe -0.651 kg) | Sqm | 161.0 | 161.0 | 18.0 | False | None | None | False | None | False | 2898.0 | 0 |
3350252 | 117816 | None | 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete | Sqm | 498.75 | 498.75 | 2.0 | False | None | None | False | None | False | 997.5 | 0 |
3350253 | 117816 | None | 11.47 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers
without pair of handles (best make of approved quality) for aluminium
doors including necessary cutting and making good etc. complete
including cost of materials, labour, usage charges of machinery complete
as per specifications. | Each | 458.85 | 458.85 | 2.0 | False | None | None | False | None | False | 917.7 | 0 |
3350254 | 117816 | None | 20.26.1 | Providing and fixing bright finished brass double acting spring hinges
with necessary brass screws etc. complete 150mm | Each | 768.6 | 768.6 | 6.0 | False | None | None | False | None | False | 4611.6 | 0 |
3350255 | 117816 | None | 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to
required colour or shade, with necessary screws etc. complete | Each | 136.5 | 136.5 | 20.0 | False | None | None | False | None | False | 2730.0 | 0 |
3350256 | 117816 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 50.0 | False | None | None | False | None | False | 3450.0 | 0 |
3350257 | 117816 | None | 1.9.1 | Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20mm | Mtr | 19.0 | 19.0 | 50.0 | False | None | None | False | None | False | 950.0 | 0 |
3350258 | 117816 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
3350259 | 117816 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 |
3350260 | 117816 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | Mtr | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
3350261 | 117816 | None | 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth
for concealing of Conduit/GI pipe and plastering, finishing upto
wall surface complete. upto 50 mm conduit in brick wall | Mtr | 29.0 | 29.0 | 20.0 | False | None | None | False | None | False | 580.0 | 0 |
3350262 | 117816 | None | 2.1.1 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Short point upto 3Mtr from tapping point to out let via switch
| Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
3350263 | 117816 | None | 2.1.2 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 |
3350264 | 117816 | None | 2.1.3 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3350265 | 117816 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Sqm | 0.41 | 0.41 | 2700.0 | False | None | None | False | None | False | 1107.0 | 0 |
3350266 | 117816 | None | 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A SP Switch | No | 55.0 | 55.0 | 8.0 | False | None | None | False | None | False | 440.0 | 0 |
3350267 | 117816 | None | 3.14.2 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Two Way Switch | No | 70.0 | 70.0 | 3.0 | False | None | None | False | None | False | 210.0 | 0 |
3350268 | 117816 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48 Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
3350269 | 117816 | None | 5.19.1 | Supplying and fixing regular MCB distribution boards on wall/wood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. I - Single Door 4 Way SP & N | Each | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |