tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719227226000 | 1 | None | None | Buildings | Construction of Additional Class Room for Govt Higher Primary School in Kangalu village of Hunsur Taluk | 1240252.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3337313 | 117142 | None | code 01 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In all kinds of soils Depth upto 3 m( PWD SR 2023-24,Vol-I, P.NO-5, I.NO-1.4.1.2) | Cum | 102.0 | 102.0 | 16.39 | False | None | None | False | None | False | 1671.78 | 0 | 3337314 | 117142 | None | code 02 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth( PWD SR 2023-24,Vol-I, P.NO-5, I.NO-1.15.1) | Cum | 363.0 | 363.0 | 22.85 | False | None | None | False | None | False | 8294.55 | 0 | 3337315 | 117142 | None | code 03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality,labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm and nominal size graded crushed coarse aggregates (PWD SR, 2023-24 Vol-I, P No-15, It No-2.1.3) | Cum | 5989.0 | 5989.0 | 8.14 | False | None | None | False | None | False | 48750.46 | 0 | 3337316 | 117142 | None | code 04 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6205.0 | 6205.0 | 18.72 | False | None | None | False | None | False | 116157.6 | 0 | 3337317 | 117142 | None | code 05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement 6 coarse sand) | Cum | 6389.0 | 6389.0 | 7.55 | False | None | None | False | None | False | 48236.95 | 0 | 3337318 | 117142 | None | code 06 | Providing Flush/ Ruled pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,
including cost of materials, labour, curing as per specifications and as
per directions of Engineer-in-charge)(PWD SR, 2023-24 Vol-II, P No-44, It No 8.19.1) | Cum | 255.0 | 255.0 | 15.0 | False | None | None | False | None | False | 3825.0 | 0 | 3337319 | 117142 | None | code 07 | Providing and injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment, creating continuous chemical barrier under
and around the column pits, walls, trenches, basement excavation, top
surface of the plinth filling, junction of wall and floor, along the external
perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of
chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specifications.(PWD SR, 2023-24 Vol-II, P No-5 It No 4.1 | Sqm | 118.0 | 118.0 | 89.23 | False | None | None | False | None | False | 10529.14 | 0 | 3337320 | 117142 | None | code 08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 6475.61 | 6475.61 | 3.42 | False | None | None | False | None | False | 22146.5862 | 0 | 3337321 | 117142 | None | code 09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & liftscost of all materials of quality, confirming to the requirements of relevant IS codes labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 10749.1 | 10749.1 | 4.29 | False | None | None | False | None | False | 46113.639 | 0 | 3337322 | 117142 | None | code 10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 9945.0 | 9945.0 | 3.49 | False | None | None | False | None | False | 34708.05 | 0 | 3337323 | 117142 | None | code 11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10608.0 | 10608.0 | 4.12 | False | None | None | False | None | False | 43704.96 | 0 | 3337324 | 117142 | None | code 12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9613.5 | 9613.5 | 0.2 | False | None | None | False | None | False | 1922.7 | 0 | 3337325 | 117142 | None | code 13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 10.23 | False | None | None | False | None | False | 101737.35 | 0 | 3337326 | 117142 | None | code 14 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification | Cum | 817.0 | 817.0 | 68.22 | False | None | None | False | None | False | 55735.74 | 0 | 3337327 | 117142 | None | code 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto1.5m | Cum | 266.0 | 266.0 | 54.21 | False | None | None | False | None | False | 14419.86 | 0 | 3337328 | 117142 | None | code 16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Kgs | 89457.0 | 89457.0 | 2.388 | False | None | None | False | None | False | 213623.316 | 0 | 3337329 | 117142 | None | code 17 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality,labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6243.0 | 6243.0 | 8.58 | False | None | None | False | None | False | 53564.94 | 0 | 3337330 | 117142 | None | code 18 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7969.0 | 7969.0 | 17.61 | False | None | None | False | None | False | 140334.09 | 0 | 3337331 | 117142 | None | code 19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 371.0 | 371.0 | 122.47 | False | None | None | False | None | False | 45436.37 | 0 | 3337332 | 117142 | None | code 20 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 255.0 | 255.0 | 138.55 | False | None | None | False | None | False | 35330.25 | 0 | 3337333 | 117142 | None | code 21 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using flats 30x6mm for diagonal braces
and central cross piece including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge | Cum | 4242.0 | 4242.0 | 5.04 | False | None | None | False | None | False | 21379.68 | 0 | 3337334 | 117142 | None | code 22 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc | Kgs | 183.0 | 183.0 | 90.72 | False | None | None | False | None | False | 16601.76 | 0 | 3337335 | 117142 | None | code 23 | Providing and fixing factory made ISI marked steel glazed doors, windows
and ventilators, side /top /centre hung, with beading and all members
such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel
sections, joints mitred and flash butt welded and sash bars tenoned
and riveted, including providing and fixing of hinges, pivots, including
priming coat of approved steel primer, but excluding the cost of other
fittings, complete all as per approved design, (sectional weight of only
steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete
block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge | Kgs | 148.0 | 148.0 | 172.8 | False | None | None | False | None | False | 25574.4 | 0 | 3337336 | 117142 | None | code 24 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete.size of tile 600mm*600mm | Sqm | 1175.0 | 1175.0 | 53.22 | False | None | None | False | None | False | 62533.5 | 0 | 3337337 | 117142 | None | code 25 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 89.0 | 89.0 | 122.47 | False | None | None | False | None | False | 10899.83 | 0 | 3337338 | 117142 | None | code 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 137.0 | 137.0 | 138.55 | False | None | None | False | None | False | 18981.35 | 0 | 3337339 | 117142 | None | code 27 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 139.0 | 139.0 | 17.46 | False | None | None | False | None | False | 2426.94 | 0 | 3337340 | 117142 | None | code 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 291.0 | 291.0 | 25.0 | False | None | None | False | None | False | 7275.0 | 0 | 3337341 | 117142 | None | code 29 | Providing and laying Chequerred precast cement concrete tiles 22 mm
thick in footpath & courtyard, jointed with neat cement slurry mixed with
pigment to match the shade of tiles, including rubbing and cleaning etc.
complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse
sand) | Sqm | 1269.0 | 1269.0 | 7.0 | False | None | None | False | None | False | 8883.0 | 0 | 3337342 | 117142 | None | code 30 | Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
including applying priming coat of approved steel primer. M.S. tube
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge | Kgs | 138.0 | 138.0 | 109.62 | False | None | None | False | None | False | 15127.56 | 0 | 3337343 | 117142 | None | code 31 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement to brick/
stone masonry including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 429.0 | 429.0 | 2.88 | False | None | None | False | None | False | 1235.52 | 0 | 3337344 | 117142 | None | code 32 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm
to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all
complete as per direction of Engineer-in-charge | Cum | 1002.0 | 1002.0 | 0.25 | False | None | None | False | None | False | 250.5 | 0 | 3337345 | 117142 | None | code 33 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10
mm, in the recharge pit, over the existing layer of boulders, in required
thickness, for all leads & lifts, all complete as per direction of Engineerin-
charge | Cum | 1186.0 | 1186.0 | 0.25 | False | None | None | False | None | False | 296.5 | 0 | 3337346 | 117142 | None | code 34 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to
2 mm in recharge pit, in required thickness over gravel layer, for all leads
& lifts, all complete as per direction of Engineer -in-charge | Cum | 1192.0 | 1192.0 | 0.25 | False | None | None | False | None | False | 298.0 | 0 | 3337347 | 117142 | None | code 35 | Providing and fixing factory made precast RCC perforated drain covers,
having concrete of strength not less than M-25, of size 1000 x 450x50 mm,
reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional
T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to
125 mm c/c, including providing edge binding with M.S. flats of size 50
mm x 1.6 mm complete, all as per direction of Engineer-in-charge | Each | 1123.0 | 1123.0 | 2.0 | False | None | None | False | None | False | 2246.0 | 0 |
| 1719227226000 | 0 | None | None | Buildings | Construction of Additional Class Room for Govt Higher Primary School in Kangalu village of Hunsur Taluk | 21469.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3337348 | 117143 | None | code 01 | Supplying heavy gauge PVC conduit pipe.dia.mm thick confirming to IS2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawlplugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. ( PWD SR 2023-24,Vol-VI, P.NO-2, I.NO-1.1.1)19/20 mm dia 2 mm thick | m | 69.0 | 69.0 | 15.0 | False | None | None | False | None | False | 1035.0 | 0 | 3337349 | 117143 | None | code 02 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box (PWD SR, 2023-24 Vol-VI, P No-2, It No-1.5.1) | Each | 49.0 | 49.0 | 10.0 | False | None | None | False | None | False | 490.0 | 0 | 3337350 | 117143 | None | code 03 | Supplying and fixing M.S. Rafter clamp set made out of M S Flat & 14 mm M S rod (PWD SR, 2023-24 Vol-VI, P No-4, It No-1.12) | Each | 160.0 | 160.0 | 10.0 | False | None | None | False | None | False | 1600.0 | 0 | 3337351 | 117143 | None | code 04 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3854 (PWD SR, 2023-24 Vol-VI, P No-8, It No-3.1.2)6A 3/5 Way | Each | 147.0 | 147.0 | 3.0 | False | None | None | False | None | False | 441.0 | 0 | 3337352 | 117143 | None | code 05 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. (PWD SR, 2023-24 Vol-VI, P No-3, It No-1.6.3)10" x 7" x 3" (254 x 178 x 76 mm) | No | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 | 3337353 | 117143 | None | code 06 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD SR, 2023-24 Vol-VI, P No-5, It No-2.1.1)Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 3.0 | False | None | None | False | None | False | 855.0 | 0 | 3337354 | 117143 | None | code 07 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD SR, 2023-24 Vol-VI, P No-5, It No-2.1.2) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3337355 | 117143 | None | code 08 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (PWD SR, 2023-24 Vol-VI, P No-5, It No-2.1.3) Long point above 6Mtr upto10Mtr from tapping point to outlet via switch | Point | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 | 3337356 | 117143 | None | code 09 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5mm2 ( PWD SR 2023-24,Vol-VI, P.NO-5, I.NO-2.3.2 | Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 | 3337357 | 117143 | None | code 10 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5mm2 ( PWD SR 2023-24,Vol-VI, P.NO-5, I.NO-2.3.3) | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | 3337358 | 117143 | None | code 11 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. ( PWD SR 2023-24,Vol-VI, P.NO-9, I.NO-3.7) | No | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 | 3337359 | 117143 | None | code 12 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V, 50Hz AC power Supply ( PWD SR 2023-24,Vol-VI, P.NO-50, I.NO-12.21) | Each | 520.0 | 520.0 | 4.0 | False | None | None | False | None | False | 2080.0 | 0 | 3337360 | 117143 | None | code 13 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. ( PWD SR 2023-24,Vol-VI, P.NO-30, I.NO-6.3.2)56" Sweep (1400 mm) Regular model | Each | 3031.0 | 3031.0 | 2.0 | False | None | None | False | None | False | 6062.0 | 0 | 3337361 | 117143 | None | code 14 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired ( PWD SR 2023-24,Vol-VI, P.NO-57, I.NO-13.11) | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | 3337362 | 117143 | None | code 15 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ( PWD SR 2023-24,Vol-VI, P.NO-17, I.NO-5.18.4)6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3337363 | 117143 | None | code 16 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. ( PWD SR 2023-24,Vol-VI, P.NO-18, I.NO-5.19.9)II - Double Door 12 Way SP & N | No | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 |
|
|
---|