| 1719406010000 | 0 | None | None | Other Works | Construction of CC Road and Laying of HDPE line on both sides of road and water connection to the houses at ward no 23 Shankara Matta beside at Sriram house front side in chintamani town | 1756574.36 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3369279 | 118529 | None | item01 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable
materials separately (V3 Page No 12 Item No 2.19) ---- GST | Cum | 579.89 | 579.89 | 149.6 | False | None | None | False | None | False | 86751.544 | 0 | | 3369280 | 118529 | None | items02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (V 1 Page no 8 Item No 1.12)
---- GST | Cum | 97.85 | 97.85 | 224.4 | False | None | None | False | None | False | 21957.54 | 0 | | 3369281 | 118529 | None | items03 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. (V3 Page No.49. Item No.6.1) ---- GST | Cum | 5067.6 | 5067.6 | 74.8 | False | None | None | False | None | False | 379056.48 | 0 | | 3369282 | 118529 | None | item04 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (V3 Page No.149. Item No.16.28)
---- GST | Cum | 6956.62 | 6956.62 | 74.8 | False | None | None | False | None | False | 520355.176 | 0 | | 3369283 | 118529 | None | item05 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50m (V-1 Page No. 6 I. No- 1.6.1)
---- GST | Cum | 498.52 | 498.52 | 288.0 | False | None | None | False | None | False | 143573.76 | 0 | | 3369284 | 118529 | None | item06 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc - PE-100 PN-6 HDPE Grade PE80-PN6.0, 90mm dia (V5 Page No.95 Item No- 9.1.3)
---- GST | Rmtr | 330.63 | 330.63 | 400.0 | False | None | None | False | None | False | 132252.0 | 0 | | 3369285 | 118529 | None | item07 | Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and Providing and laying of MDPE pipe (PE80)-PN 25mm dia manufactured in accordance with ISO 4427-1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm/GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. "A" class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making "U" shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on the distribution main pipe with SS / Brass ferrule of size 1/2" x 3/4" and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles, PE 100 black colour pipe of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter cum flow regulator, water tight cap with O'ring, long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for drinking water service in WRC - NSF, UK and DVGW certificate, Germany. The Saddle should be manufactured Virgin Compounded PE 100 material. Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, as per diagram, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for the following diameters: (for minimum length of 2m) etc. complet (V5 Page No 21 Item NO 2.21.2) ---- GST | Rmtr | 6870.1 | 6870.1 | 40.0 | False | None | None | False | None | False | 274804.0 | 0 | | 3369286 | 118529 | None | item08 | For connection pipe length beyond 2.0 mtrs for every 1 mtr. or part thereof (V5 Page No 21 Item NO 2.21.4)
---- GST | Rmtr | 973.35 | 973.35 | 80.0 | False | None | None | False | None | False | 77868.0 | 0 | | 3369287 | 118529 | None | item09 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For sluice Valve of PN -10.0 and 80mm (V5 Page No.22 I.No-2.23.2)
---- GST | Nos | 10704.79 | 10704.79 | 2.0 | False | None | None | False | None | False | 21409.58 | 0 | | 3369288 | 118529 | None | item10 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications (V1 Page No.7 I.No-1.10)
---- GST | Cum | 483.07 | 483.07 | 204.0 | False | None | None | False | None | False | 98546.28 | 0 |
|