| 3315934 | 115873 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 7.0632 | False | None | None | False | None | False | 742.059792 | 0 |
| 3315935 | 115873 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 0.7247 | False | None | None | False | None | False | 4470.435149 | 0 |
| 3315936 | 115873 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 6.644 | False | None | None | False | None | False | 38397.86852 | 0 |
| 3315937 | 115873 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 0.823 | False | None | None | False | None | False | 5270.08873 | 0 |
| 3315938 | 115873 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 6.5426 | False | None | None | False | None | False | 1792.541548 | 0 |
| 3315939 | 115873 | None | code06 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm | Sqm | 1114.46 | 1114.46 | 10.5 | False | None | None | False | None | False | 11701.83 | 0 |
| 3315940 | 115873 | None | code07 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 364.62 | 364.62 | 11.7 | False | None | None | False | None | False | 4266.054 | 0 |
| 3315941 | 115873 | None | code08 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 91.67 | 91.67 | 12.6 | False | None | None | False | None | False | 1155.042 | 0 |
| 3315942 | 115873 | None | code09 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 0.2624 | False | None | None | False | None | False | 2156.230016 | 0 |
| 3315943 | 115873 | None | code10 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | l | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 |
| 3315944 | 115873 | None | code11 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 116.39 | 116.39 | 250.0 | False | None | None | False | None | False | 29097.5 | 0 |
| 3315945 | 115873 | None | code12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussese and including cutting to size and shape wherever required. | Sqm | 585.04 | 585.04 | 53.0 | False | None | None | False | None | False | 31007.12 | 0 |
| 3315946 | 115873 | None | code13 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO,UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 1000 LPH SS : Skid Type | Each | 454230.0 | 454230.0 | 1.0 | False | None | None | False | None | False | 454230.0 | 0 |
| 3315947 | 115873 | None | code14 | Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m (PWD SR 2021-22 Vol:1 P.NO.10 I.No:1.19.1) | Cum | 269.86 | 269.86 | 13.5 | False | None | None | False | None | False | 3643.11 | 0 |
| 3315948 | 115873 | None | code15 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including
jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete 75mm ( weight of pipe -0.651 kg) | m | 165.83 | 165.83 | 25.0 | False | None | None | False | None | False | 4145.75 | 0 |
| 3315949 | 115873 | None | code16 | Refilling available earth around trenches pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 13.5 | False | None | None | False | None | False | 2224.8 | 0 |
| 3315950 | 115873 | None | code17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2343.25 | 2343.25 | 6.25 | False | None | None | False | None | False | 14645.3125 | 0 |
| 3315951 | 115873 | None | code18 | Providing and fixing double glazed hermetically sealed glazing in alu minium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4475.35 | 4475.35 | 2.25 | False | None | None | False | None | False | 10069.5375 | 0 |
| 3315952 | 115873 | None | code19 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch | Point | 276.0 | 276.0 | 1.0 | False | None | None | False | None | False | 276.0 | 0 |
| 3315953 | 115873 | None | code20 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 2.0 | False | None | None | False | None | False | 772.0 | 0 |
| 3315954 | 115873 | None | code21 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 3.0 | False | None | None | False | None | False | 1701.0 | 0 |
| 3315955 | 115873 | None | code22 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 123.0 | 123.0 | 1.0 | False | None | None | False | None | False | 123.0 | 0 |
| 3315956 | 115873 | None | code23 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
| 3315957 | 115873 | None | code24 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 152.0 | 152.0 | 2.0 | False | None | None | False | None | False | 304.0 | 0 |
| 3315958 | 115873 | None | code25 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 |
| 3315959 | 115873 | None | code26 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way Switch | Each | 88.0 | 88.0 | 2.0 | False | None | None | False | None | False | 176.0 | 0 |
| 3315960 | 115873 | None | code27 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 |
| 3315961 | 115873 | None | code28 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 163.0 | 163.0 | 2.0 | False | None | None | False | None | False | 326.0 | 0 |
| 3315962 | 115873 | None | code29 | Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick | m | 68.0 | 68.0 | 50.0 | False | None | None | False | None | False | 3400.0 | 0 |
| 3315963 | 115873 | None | code30 | Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | m | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 |
| 3315964 | 115873 | None | code31 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm | m | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
| 3315965 | 115873 | None | code32 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm | m | 40.0 | 40.0 | 40.0 | False | None | None | False | None | False | 1600.0 | 0 |
| 3315966 | 115873 | None | code33 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4.0 sqmm | m | 59.0 | 59.0 | 30.0 | False | None | None | False | None | False | 1770.0 | 0 |
| 3315967 | 115873 | None | code34 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
| 3315968 | 115873 | None | code35 | Supplying and fixing of slim patty fitting, made out of CRCA
Sheet metal body with locking type holder completely wired.
Excluding Ballast & Flouresent Tube.1 x 2' Tube light fitting. | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 |
| 3315969 | 115873 | None | code36 | Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. | Each | 275.0 | 275.0 | 3.0 | False | None | None | False | None | False | 825.0 | 0 |
| 3315970 | 115873 | None | code37 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 1.0 | False | None | None | False | None | False | 119.0 | 0 |
| 3315971 | 115873 | None | code38 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) | m | 76.0 | 76.0 | 10.0 | False | None | None | False | None | False | 760.0 | 0 |
| 3315972 | 115873 | None | code39 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 |