| 1719480316000 | 0 | None | None | Buildings | Construction of Remaining Compound wall around SWM land fill site and construction of Control Panel Board room in SWM landfill site of Kanakapura CMC limit | 3657808.85 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3382327 | 119131 | None | code1 | Concealed Conduit System, Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends,metal/PVC Junction boxes,adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinfor cement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18 SWG GI fish wire wherever necessary (P.No.1, I.No.1.2.1.2023-24 PWD Volume-6 Electrical SR) | Mtr | 67.98 | 67.98 | 50.0 | False | None | None | False | None | False | 3399.0 | 0 | | 3382328 | 119131 | None | code2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall beterminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.05,I.No.2.2.5 of 2023-24 PWD Electrical Volume-6 SR) | No | 1018.67 | 1018.67 | 6.0 | False | None | None | False | None | False | 6112.02 | 0 | | 3382329 | 119131 | None | code3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall,including necessary rawlplugs, Machine/NF screws etc., complete.(P.No.08,I.No. 3.3.6 of 2023-24 PWD Electrical Volume-6 SR) | No | 268.83 | 268.83 | 1.0 | False | None | None | False | None | False | 268.83 | 0 | | 3382330 | 119131 | None | code4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.09 ,I.No.3.6.1, of 2023-24 PWD Electrical Volume-6 SR) | No | 105.06 | 105.06 | 10.0 | False | None | None | False | None | False | 1050.6 | 0 | | 3382331 | 119131 | None | code5 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.08, I.No. 3.6.3, of 2023-24 PWD Electrical Volume-6 SR) | No | 176.13 | 176.13 | 2.0 | False | None | None | False | None | False | 352.26 | 0 | | 3382332 | 119131 | None | code6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. (P.No.08,I.No.3.5.6 of 2023-24 PWD Electrical Volume-6 SR) | No | 354.32 | 354.32 | 1.0 | False | None | None | False | None | False | 354.32 | 0 | | 3382333 | 119131 | None | code7 | Supplying and fixing regular MCB distribution boards on wall/Woodboard/flush mounting using required clamps,bolts,nuts etc.,with provision for fixing suitable type capacity MCB's single phase/3phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (P.No.18,I.No.5.19.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 1278.23 | 1278.23 | 1.0 | False | None | None | False | None | False | 1278.23 | 0 | | 3382334 | 119131 | None | code8 | Supplying And Fixing Metal Fan Box with Round Hook. (P.No.04,I.No.1.13 of 2023-24 PWD Electrical Volume-6 SR) | No | 120.51 | 120.51 | 2.0 | False | None | None | False | None | False | 241.02 | 0 | | 3382335 | 119131 | None | code9 | Supplying capacitor type ceiling fan complete with downrod blades,shackle,canopies etc,for operation on 230V, 50 cycles.Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.(P.No.30,I.No.6.3.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 3073.52 | 3073.52 | 2.0 | False | None | None | False | None | False | 6147.04 | 0 | | 3382336 | 119131 | None | code10 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. (P.No.21,I.No.5.46.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 216.3 | 216.3 | 4.0 | False | None | None | False | None | False | 865.2 | 0 | | 3382337 | 119131 | None | code11 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80.Power Input 220-240V @ 50/ 60Hz & Power factor 0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.P.No.43,I.No.11.3.1 & 11.3.2 of 2023-24 PWD Electrical Volume-6 SR | No | 710.7 | 710.7 | 6.0 | False | None | None | False | None | False | 4264.2 | 0 | | 3382338 | 119131 | None | code12 | Fixing all types and all capacities of fluorescent /falseceiling /spotlight/CFL/LEDfittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. (P.No.56,I.No.13.7.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 125.66 | 125.66 | 6.0 | False | None | None | False | None | False | 753.96 | 0 | | 3382339 | 119131 | None | code13 | Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A.ceilingrose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(P.No.57,I.No.13.10 of 2023-24 PWD Electrical Volume-6 SR) | No | 176.13 | 176.13 | 2.0 | False | None | None | False | None | False | 352.26 | 0 | | 3382340 | 119131 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir draft, approach channels, key trench, foundation of Buildings & Bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (I. No 1.4.1 P. No-5 of PWD Vol-1 SR 2023-24) | Cum | 249.26 | 249.26 | 300.77 | False | None | None | False | None | False | 74969.9302 | 0 | | 3382341 | 119131 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Pg No. 15, It No. 2.1.2 VOL-1 of PWD SR 2023-24) | Cum | 5833.92 | 5833.92 | 34.34 | False | None | None | False | None | False | 200336.8128 | 0 | | 3382342 | 119131 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.1.1 P. No-9 of PWD & IWTD, Vol-2 SR 2023) | Cum | 6391.15 | 6391.15 | 60.75 | False | None | None | False | None | False | 388262.3625 | 0 | | 3382343 | 119131 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.1.1 P. No-9 of PWD & IWTD, Vol-2 SR 2023) | Cum | 5779.33 | 5779.33 | 4.81 | False | None | None | False | None | False | 27798.5773 | 0 | | 3382344 | 119131 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.4 P. No-9 of PWD & IWTD, Vol-2 SR 2023) | Cum | 6580.67 | 6580.67 | 3.6 | False | None | None | False | None | False | 23690.412 | 0 | | 3382345 | 119131 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.1.6, P. No-15 of PWD & IWTD, Vol-1 SR 2023 | Cum | 6430.29 | 6430.29 | 1.7 | False | None | None | False | None | False | 10931.493 | 0 | | 3382346 | 119131 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.2.1 P. No-15 of PWD & IWTD, Vol-1 SR 2023-24) | Cum | 6799.39 | 6799.39 | 45.53 | False | None | None | False | None | False | 309576.2267 | 0 | | 3382347 | 119131 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (I. No 6.33 P. No-17 of PWD Vol-2 SR 2023-24) | Sqm | 1267.93 | 1267.93 | 64.83 | False | None | None | False | None | False | 82199.9019 | 0 | | 3382348 | 119131 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.2.1 P. No-15 of PWD Vol-2 SR 2023-24) | Cum | 9713.42 | 9713.42 | 4.16 | False | None | None | False | None | False | 40407.8272 | 0 | | 3382349 | 119131 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.. (Pg No. 18, ItNo. 2.11 h VOL-1 of PWD SR 2023) | Tonne | 81381.33 | 81381.33 | 7.85 | False | None | None | False | None | False | 638843.4405 | 0 | | 3382350 | 119131 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications . (I. No 6.32 P. No-17 of PWD , Vol-2 SR 2023-24 ) | Sqm | 1349.3 | 1349.3 | 630.0 | False | None | None | False | None | False | 850059.0 | 0 | | 3382351 | 119131 | None | code12 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Pg No. 15, It No. 2.1.4 VOL-1 of PWD SR 2023-24) | Cum | 6403.51 | 6403.51 | 3.0 | False | None | None | False | None | False | 19210.53 | 0 | | 3382352 | 119131 | None | code13 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.2.2, P. No-41 of PWD , Vol-2 SR 2023-24) | Sqm | 287.37 | 287.37 | 1521.12 | False | None | None | False | None | False | 437124.2544 | 0 | | 3382353 | 119131 | None | code14 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge .(I. No 8.1.2, P. No-41 of PWD , Vol-2 SR 2023-24) | Sqm | 248.23 | 248.23 | 77.85 | False | None | None | False | None | False | 19324.7055 | 0 | | 3382354 | 119131 | None | code15 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(I. No 8.35.2 P. No-47 of PWD , Vol-2 SR 2023-24) | Sqm | 203.94 | 203.94 | 1435.5 | False | None | None | False | None | False | 292755.87 | 0 | | 3382355 | 119131 | None | code16 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of
total length of barbed wire used. With G.I. barbed wire .(I. No 11.57.1 P. No-94 of PWD , Vol-2 SR 2023-24) | Mtr | 18.54 | 18.54 | 1600.0 | False | None | None | False | None | False | 29664.0 | 0 | | 3382356 | 119131 | None | code17 | Supply at Site Angle iron post & Strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and holes upto 10 mm dia. Etc. complete (I. No 11.57.2 P. No-94 of PWD & IWTD, Vol-2 SR 2023-24) | Kg | 116.39 | 116.39 | 1010.0 | False | None | None | False | None | False | 117553.9 | 0 | | 3382357 | 119131 | None | code18 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete (I. No 9.1 , P. No-59 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 464.53 | 464.53 | 20.16 | False | None | None | False | None | False | 9364.9248 | 0 | | 3382358 | 119131 | None | code19 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). .. (I. No 12.95, P. No-112 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 4543.33 | 4543.33 | 1.89 | False | None | None | False | None | False | 8586.8937 | 0 | | 3382359 | 119131 | None | code20 | Providing & fixing of 2-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) . (I. No 12.84 , P. No108 of PWD & IWTD, Vol-2 SR 2023-24 | Sqm | 5173.69 | 5173.69 | 2.88 | False | None | None | False | None | False | 14900.2272 | 0 | | 3382360 | 119131 | None | code21 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (I. No 12.93.1 , P. No.111 of PWD & IWTD, Vol-2 SR 2023-24 | Mtr | 723.06 | 723.06 | 14.7 | False | None | None | False | None | False | 10628.982 | 0 | | 3382361 | 119131 | None | code22 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (I. No 12.93.1 , P. No.111 of PWD & IWTD, Vol-2 SR 2023-24 | Kg | 116.39 | 116.39 | 70.0 | False | None | None | False | None | False | 8147.3 | 0 | | 3382362 | 119131 | None | code23 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.28 S P. No-45 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 91.67 | 91.67 | 85.62 | False | None | None | False | None | False | 7848.7854 | 0 | | 3382363 | 119131 | None | code24 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (I. No 8.39 P. No-48 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 130.81 | 130.81 | 77.85 | False | None | None | False | None | False | 10183.5585 | 0 |
|