createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719467000182
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3750.00
emd297000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 16:00:00
tenderQueryClose02-07-2024 11:30:00
technicalBidOpen12-07-2024 16:30:00
publishedDate27-06-2024 12:19:00
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate03-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843360
tenderSupplierListNone
tenderSchedule
createdTs1719467000223
version8
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT407
titlePackage KLR&CBP-(1)Construction of Block Level Public Health Unit at GH Srinivasapura in Kolar District.(2)Construction of Block Level Public Health Unit at GH Bangarapet in Kolar District.(3)Construction of Block Level Public Health Unit on First Floor at GH Gudibande in Chikkaballapura District.
descriptionConstruction of Block Level Public Health Unit at GH Srinivasapura and GH Bangarapet in Kolar District and at GH Gudibande in Chikkaballapura District.
categoryWORKS
categoryTextWorks
ecv15000000.00
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount15000000.0
groupOverheadTotal178544.26
fileNumberAEE/HFWD/KLR/BPHU/Package-KLRandCBP
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194670000000NoneNoneBuildingsConstruction of Block Level Public Health Unit at GH Srinivasapura in Kolar District.4997184.26
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3373368118770NoneV-3_Pg9_2.5(ii)aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete with all lead100 Sqm477.65477.652.175FalseNoneNoneFalseNoneFalse1038.888750
3373369118770NoneV-1_Pg8_1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.4665.247FalseNoneNoneFalseNoneFalse7533.418620
3373370118770NoneV-1_Pg8_1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.9794.892FalseNoneNoneFalseNoneFalse11763.761240
3373371118770NoneV-1_Pg8_1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum441.19441.199.776FalseNoneNoneFalseNoneFalse4313.073440
3373372118770NoneV-3_Pg5_1.1 (a)Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Tipper 5.5 Cum ) ---- etc., complete with all leadCum164.08164.0859.776FalseNoneNoneFalseNoneFalse9808.046080
3373373118770NoneV-2_Pg5_4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadCum143.42143.42182.35FalseNoneNoneFalseNoneFalse26152.6370
3373374118770NoneV-1_Pg7_1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.395.66FalseNoneNoneFalseNoneFalse30926.8780
3373375118770NoneV-1_Pg7_1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.161.242FalseNoneNoneFalseNoneFalse35281.51620
3373376118770NoneV-1_Pg15_2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0322.59FalseNoneNoneFalseNoneFalse164433.28770
3373377118770NoneV-1_Pg15_2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8316.848316.8417.253FalseNoneNoneFalseNoneFalse143490.440520
3373378118770NoneV-1_Pg15_2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTALS ---- etc., complete with all leadCum8470.858470.852.588FalseNoneNoneFalseNoneFalse21922.55980
3373379118770NoneV-1_Pg16_2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMNS-GROUND FLOOR ---- etc., complete with all leadCum14138.8714138.879.005FalseNoneNoneFalseNoneFalse127320.524350
3373380118770NoneV-1_Pg16_2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM-GROUND FLOOR ---- etc., complete with all leadCum12475.4712475.4718.101FalseNoneNoneFalseNoneFalse225818.482470
3373381118770NoneV-1_Pg16_2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS-GROUND FLOOR ---- etc., complete with all leadCum13307.1713307.1710.895FalseNoneNoneFalseNoneFalse144981.617150
3373382118770NoneV-1_Pg16_2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC SLAB-GROUND FLOOR ---- etc., complete with all leadCum12475.4712475.4719.51FalseNoneNoneFalseNoneFalse243396.41970
3373383118770NoneV-1_Pg16_2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTELS-GROUND FLOOR ---- etc., complete with all leadCum13307.1713307.172.281FalseNoneNoneFalseNoneFalse30353.654770
3373384118770NoneV-1_Pg15_2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates -GROUND FLOOR Sill concrete ---- etc., complete with all leadCum10956.4110956.413.347FalseNoneNoneFalseNoneFalse36671.104270
3373385118770NoneV-3_Pg135_15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all leadNo.247.94247.9410.0FalseNoneNoneFalseNoneFalse2479.40
3373386118770NoneV-2_Pg44_8.16aKSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1386.51386.54.5FalseNoneNoneFalseNoneFalse6239.250
3373387118770NoneV-1_Pg84_2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadt108726.04108726.047.48FalseNoneNoneFalseNoneFalse813270.77920
3373388118770None18-19 SR_Pg15_4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadm38.9438.9454.0FalseNoneNoneFalseNoneFalse2102.760
3373389118770NoneV-2_Pg54_8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. ---- etc., complete with all leadm80.2280.2254.0FalseNoneNoneFalseNoneFalse4331.880
3373390118770NoneV-2_Pg9_5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.191.62FalseNoneNoneFalseNoneFalse12579.60780
3373391118770NoneV-2_Pg17_6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17164.48FalseNoneNoneFalseNoneFalse261880.12160
3373392118770NoneV-2_Pg17_6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.867.326FalseNoneNoneFalseNoneFalse90338.02680
3373393118770NoneV-2_Pg100_12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.750.689FalseNoneNoneFalseNoneFalse82748.727750
3373394118770NoneV-2_Pg104_12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1817.481817.4812.0FalseNoneNoneFalseNoneFalse21809.760
3373395118770NoneV-2_Pg105_12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.612.0FalseNoneNoneFalseNoneFalse15343.20
3373396118770NoneV-2_Pg105_12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos1203.251203.2512.0FalseNoneNoneFalseNoneFalse14439.00
3373397118770NoneV-2_Pg105_12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.0524.0FalseNoneNoneFalseNoneFalse6913.20
3373398118770NoneV-2_Pg105_12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos158.0158.024.0FalseNoneNoneFalseNoneFalse3792.00
3373399118770NoneV-2_Pg105_12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.8512.0FalseNoneNoneFalseNoneFalse802.20
3373400118770NoneV-2_Pg108_12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2424.0FalseNoneNoneFalseNoneFalse8021.760
3373401118770NoneV-2_Pg69_10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9272.0FalseNoneNoneFalseNoneFalse5250.240
3373402118770None18-19SR_PgXII_309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadm15.4515.4577.6FalseNoneNoneFalseNoneFalse1198.920
3373403118770NoneV-2_Pg105_12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.564037.5628.56FalseNoneNoneFalseNoneFalse115312.71360
3373404118770NoneV-2_Pg110_12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8184.58184.527.0FalseNoneNoneFalseNoneFalse220981.50
3373405118770NoneV-2_Pg109_12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.871.44FalseNoneNoneFalseNoneFalse10009.25280
3373406118770NoneV-2_Pg86_11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg178.66178.66597.24FalseNoneNoneFalseNoneFalse106702.89840
3373407118770NoneV-2_Pg112_12.96Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadm781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
3373408118770NoneV-2_Pg112_12.97.1Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames ---- etc., complete with all leadSqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
3373409118770NoneV-2_Pg105_12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.9612.0FalseNoneNoneFalseNoneFalse16247.520
3373410118770NoneV-2_Pg41_8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.2410.721FalseNoneNoneFalseNoneFalse155745.40320
3373411118770NoneV-2_Pg50_8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.54681.799FalseNoneNoneFalseNoneFalse82865.850460
3373412118770NoneV-2_Pg42_8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm411.82411.82280.5FalseNoneNoneFalseNoneFalse115515.510
3373413118770NoneV-2_Pg43_8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment - Plaster mesh 150mm wide ---- etc., complete with all leadm46.1946.19807.0FalseNoneNoneFalseNoneFalse37275.330
3373414118770None18-19SR_Pg69_10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm254.88254.8810.0FalseNoneNoneFalseNoneFalse2548.80
3373415118770NoneV-2_Pg54_8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.263.2256.0FalseNoneNoneFalseNoneFalse16179.20
3373416118770NoneV-2_Pg61_9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm ---- etc., complete with all leadSqm1428.11428.1168.8FalseNoneNoneFalseNoneFalse241063.280
3373417118770NoneV-2_Pg41_8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm358.54358.5442.84FalseNoneNoneFalseNoneFalse15359.85360
3373418118770NoneV-2_Pg63_9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2997.182997.1835.268FalseNoneNoneFalseNoneFalse105704.544240
3373419118770NoneV-2_Pg150_15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm747.47747.478.34FalseNoneNoneFalseNoneFalse6233.89980
3373420118770NoneV-2_Pg60_9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1080.491080.498.34FalseNoneNoneFalseNoneFalse9011.28660
3373421118770NoneV-2_Pg65_9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1761.111761.1142.84FalseNoneNoneFalseNoneFalse75445.95240
3373422118770NoneV-2_Pg48_8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36681.799FalseNoneNoneFalseNoneFalse105242.493640
3373423118770NoneV-2_Pg45_8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.6280.5FalseNoneNoneFalseNoneFalse53182.80
3373424118770NoneV-2_Pg47_8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7728.44FalseNoneNoneFalseNoneFalse1728.29880
3373425118770NoneV-2_Pg48_8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7728.44FalseNoneNoneFalseNoneFalse3975.05880
3373426118770NoneV-2_Pg47_8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4264.4268.544FalseNoneNoneFalseNoneFalse4415.604480
3373427118770NoneV-2_Pg133_15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm1002.911002.91172.0FalseNoneNoneFalseNoneFalse172500.520
3373428118770NoneV-5_PgA-44_647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm313.03313.0324.0FalseNoneNoneFalseNoneFalse7512.720
3373429118770NoneJobPreparation of detailed Structural designs and drawings including Soil exploration & proof checking and Providing consultancy for Architectural design and drawings floor wise. MEP design and drawings. Electrical services, Lift, Net Working, HVAC, Fire Fighting, Modular OT, interior layout and Providing consultancy services for water supply & sanitary, electrical drawings & any other related drawings to this work and liaison with other department and approval of pollution control board and allied works etc., -- complete as per specification with all lead & lift and as per the directions of the Engineer-In-Charge of the work. ---- etc., complete with all leadEach41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3373430118770NoneV-2_Pg136_14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach111.82111.828.0FalseNoneNoneFalseNoneFalse894.560
3373431118770NoneV-5_Pg191_16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, From Sink & Urinal lines ---- etc., complete with all leadm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3373432118770NoneV-5_PgA-44_657PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- etc., complete with all leadm149.49149.4940.0FalseNoneNoneFalseNoneFalse5979.60
3373433118770NoneV-5_PgA-44_647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm309.93309.9335.0FalseNoneNoneFalseNoneFalse10847.550
3373434118770NoneV-2_Pg125_13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3373435118770NoneV-2_Pg136_14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1482.791482.794.0FalseNoneNoneFalseNoneFalse5931.160
3373436118770NoneV-2_Pg131_14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach7264.457264.454.0FalseNoneNoneFalseNoneFalse29057.80
3373437118770NoneV-2_Pg145_14.95bProviding and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - Premium ---- etc., complete with all leadEach1239.711239.714.0FalseNoneNoneFalseNoneFalse4958.840
3373438118770NoneV-2_Pg128_13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach296.56296.566.0FalseNoneNoneFalseNoneFalse1779.360
3373439118770NoneV-2_Pg126_14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos.6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3373440118770NoneV-2_Pg119_13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos881.17881.174.0FalseNoneNoneFalseNoneFalse3524.680
3373441118770NoneV-2_Pg132_14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3373442118770NoneV-2_Pg122_13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3373443118770NoneV-2_Pg122_13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm460.64460.6445.0FalseNoneNoneFalseNoneFalse20728.80
3373444118770NoneV-2_Pg122_13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3373445118770NoneV-2_Pg122_13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3373446118770NoneV-5_Pg191_16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadNos.6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3373447118770NoneV-2_Pg127_13.58Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadNos.420.53420.532.0FalseNoneNoneFalseNoneFalse841.060
3373448118770NoneV-2_Pg123_13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3373449118770NoneV2_2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint326.94326.9410.0FalseNoneNoneFalseNoneFalse3269.40
3373450118770NoneV2_2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint460.64460.6412.0FalseNoneNoneFalseNoneFalse5527.680
3373451118770NoneV2_2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3373452118770NoneV2_2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3373453118770NoneV2_3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all leadEach167.73167.735.0FalseNoneNoneFalseNoneFalse838.650
3373454118770NoneV2_3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way ---- etc., complete with all leadEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
3373455118770NoneV2_3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3373456118770NoneV2_3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3373457118770NoneV2_3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all leadEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3373458118770NoneV2_3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach387.71387.7114.0FalseNoneNoneFalseNoneFalse5427.940
3373459118770NoneV2_3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.515.0FalseNoneNoneFalseNoneFalse832.550
3373460118770NoneV2_3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach195.68195.685.0FalseNoneNoneFalseNoneFalse978.40
3373461118770NoneV2_3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all leadEach212.7212.73.0FalseNoneNoneFalseNoneFalse638.10
3373462118770NoneV2_3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3373463118770NoneV2_3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3373464118770NoneV2_3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach418.1418.114.0FalseNoneNoneFalseNoneFalse5853.40
3373465118770NoneV2_3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach123.97123.9775.0FalseNoneNoneFalseNoneFalse9297.750
3373466118770NoneV2_3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach207.83207.8330.0FalseNoneNoneFalseNoneFalse6234.90
3373467118770NoneV2_3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.910.0FalseNoneNoneFalseNoneFalse4339.00
3373468118770NoneV2_3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3373469118770NoneV2_3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3373470118770NoneV2_3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all leadEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3373471118770NoneV2_1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo142.2142.210.0FalseNoneNoneFalseNoneFalse1422.00
3373472118770NoneV2_1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadm80.2280.22250.0FalseNoneNoneFalseNoneFalse20055.00
3373473118770NoneV2_1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadm94.894.8300.0FalseNoneNoneFalseNoneFalse28440.00
3373474118770NoneV2_1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadm125.19125.1970.0FalseNoneNoneFalseNoneFalse8763.30
3373475118770NoneV2_1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadm82.6582.65150.0FalseNoneNoneFalseNoneFalse12397.50
3373476118770NoneV2_1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3373477118770NoneV2_1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3230.0FalseNoneNoneFalseNoneFalse3609.60
3373478118770NoneV2_2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm31.631.6180.0FalseNoneNoneFalseNoneFalse5688.00
3373479118770NoneV2_2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm51.0551.05600.0FalseNoneNoneFalseNoneFalse30630.00
3373480118770NoneV2_2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm76.5776.57250.0FalseNoneNoneFalseNoneFalse19142.50
3373481118770NoneV2_2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3373482118770NoneV2_5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door12 Way SP & N ---- etc., complete with all leadEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3373483118770NoneV2_5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door4 Way TPN DB ---- etc., complete with all leadEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3373484118770NoneV2_5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach504.39504.3920.0FalseNoneNoneFalseNoneFalse10087.80
3373485118770NoneV2_5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach985.69985.691.0FalseNoneNoneFalseNoneFalse985.690
3373486118770NoneV2_5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3373487118770NoneV2_5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole ---- etc., complete with all leadEach5198.275198.271.0FalseNoneNoneFalseNoneFalse5198.270
3373488118770NoneV2_32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all leadKm169607.85169607.850.1FalseNoneNoneFalseNoneFalse16960.7850
3373489118770NoneV2_21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm25384.8425384.840.1FalseNoneNoneFalseNoneFalse2538.4840
3373490118770NoneSR 19-20_ 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia ---- etc., complete with all leadEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3373491118770NoneSR 19-20_6.2Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo4897.04897.02.0FalseNoneNoneFalseNoneFalse9794.00
3373492118770NoneSR 19-20_6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadMtr88.588.515.0FalseNoneNoneFalseNoneFalse1327.50
3373493118770NoneV2_11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6320.0FalseNoneNoneFalseNoneFalse16772.60
3373494118770NoneV2_11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.638.0FalseNoneNoneFalseNoneFalse8605.040
3373495118770NoneV2_11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRImore than 70%. efficacy more than80 lumen per watt, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3373496118770NoneV2_12.46Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRImore than 70%. efficacy more than80 lumen per watt, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach76.5776.574.0FalseNoneNoneFalseNoneFalse306.280
3373497118770NoneV2_40757Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencymore than130lm/w, nominal CRI more than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- etc., complete with all leadNo4890.774890.771.0FalseNoneNoneFalseNoneFalse4890.770
3373498118770NoneV2_6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.384.0FalseNoneNoneFalseNoneFalse7253.520
3373499118770NoneV2_6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.7510.0FalseNoneNoneFalseNoneFalse36267.50
3373500118770NoneV2_13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2828.0FalseNoneNoneFalseNoneFalse4151.840
3373501118770NoneV2_13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach382.85382.8510.0FalseNoneNoneFalseNoneFalse3828.50
3373502118770NoneV2_13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.29859.294.0FalseNoneNoneFalseNoneFalse3437.160
3373503118770NoneV2_13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3373504118770NoneV2_13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3373505118770NoneV2_5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3373506118770NoneV2_5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.962.0FalseNoneNoneFalseNoneFalse5991.920
3373507118770NoneV2_5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm370.7370.78.0FalseNoneNoneFalseNoneFalse2965.60
3373508118770NoneV2_5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.848.0FalseNoneNoneFalseNoneFalse7350.720
3373509118770NoneV2_5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 63A/100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3373510118770NoneV2_5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3373511118770NoneV2_5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3373512118770NoneV2_5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPN ---- etc., complete with all leadEach3699.683699.682.0FalseNoneNoneFalseNoneFalse7399.360
3373513118770NoneV2_5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3373514118770NoneV2_5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3373515118770NoneV2_5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3373516118770NoneV2_5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
17194670000000NoneNoneBuildingsConstruction of Block Level Public Health Unit at GH Bangarapet in Kolar District.4893904.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3373517118771NoneV3_Pg9_2.5(ii) aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle ---- etc., complete with all lead100 Sqm477.65477.651.37FalseNoneNoneFalseNoneFalse654.38050
3373518118771NoneV1_Pg8_1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.4634.09FalseNoneNoneFalseNoneFalse3936.03140
3373519118771None1.14.1V1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.97223.94FalseNoneNoneFalseNoneFalse27761.84180
3373520118771NoneV1_Pg8_1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum441.19441.196.16FalseNoneNoneFalseNoneFalse2717.73040
3373521118771NoneV3_Pg5_1.1 aLoading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 5.5 m3) ---- etc., complete with all leadCum164.08164.0840.25FalseNoneNoneFalseNoneFalse6604.220
3373522118771NoneV2_Pg5_4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadSqm143.42143.42122.12FalseNoneNoneFalseNoneFalse17514.45040
3373523118771NoneV1_Pg7_1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3223.94FalseNoneNoneFalseNoneFalse72399.8020
3373524118771NoneV1_Pg7_1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting is done manually to meet the requirement complete as per specifications, including cost of labour,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum547.29547.2925.02FalseNoneNoneFalseNoneFalse13693.19580
3373525118771NoneV1_Pg15_2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum6884.036884.0324.47FalseNoneNoneFalseNoneFalse168452.21410
3373526118771NoneV1_Pg15_2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Footings ---- etc., complete with all leadCum8316.848316.8417.46FalseNoneNoneFalseNoneFalse145212.02640
3373527118771NoneV1_Pg15_2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Pedestals ---- etc., complete with all leadCum8470.858470.852.01FalseNoneNoneFalseNoneFalse17026.40850
3373528118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Columns Ground floor ---- etc., complete with all leadCum14138.8714138.877.76FalseNoneNoneFalseNoneFalse109717.63120
3373529118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Curtain walls ---- etc., complete with all leadCum11227.9311227.932.69FalseNoneNoneFalseNoneFalse30203.13170
3373530118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Plinth beams ---- etc., complete with all leadCum12475.4712475.477.79FalseNoneNoneFalseNoneFalse97183.91130
3373531118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Lintel beams Ground floor ---- etc., complete with all leadCum13307.1713307.172.18FalseNoneNoneFalseNoneFalse29009.63060
3373532118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Chejjas Ground floor ---- etc., complete with all leadCum12059.6212059.621.03FalseNoneNoneFalseNoneFalse12421.40860
3373533118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Roof beams Ground floor ---- etc., complete with all leadCum13307.1713307.175.04FalseNoneNoneFalseNoneFalse67068.13680
3373534118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Roof slab Ground floor ---- etc., complete with all leadCum12475.4712475.4714.26FalseNoneNoneFalseNoneFalse177900.20220
3373535118771NoneV1_Pg16_2.1.4Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates including formwork For Cills Ground floor ---- etc., complete with all leadCum11285.9611285.960.93FalseNoneNoneFalseNoneFalse10495.94280
3373536118771NoneV3_Pg135_15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ Epoxy Ground floor ---- etc., complete with all leadNos247.94247.945.0FalseNoneNoneFalseNoneFalse1239.70
3373537118771NoneV1_Pg18_2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings Ground floor ---- etc., complete with all leadt108726.04108726.044.49FalseNoneNoneFalseNoneFalse488179.91960
3373538118771NoneV2_Pg9_5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Ground floor ---- etc., complete with all leadCum7765.197765.191.62FalseNoneNoneFalseNoneFalse12579.60780
3373539118771NoneV2_Pg17_6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground floor ---- etc., complete with all leadSqm1592.171592.17117.8FalseNoneNoneFalseNoneFalse187557.6260
3373540118771NoneV2_Pg17_6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground floor ---- etc., complete with all leadSqm1341.81341.858.11FalseNoneNoneFalseNoneFalse77971.9980
3373541118771NoneV2_Pg100_12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground floor ---- etc., complete with all leadCum120099.75120099.750.41FalseNoneNoneFalseNoneFalse49240.89750
3373542118771NoneV2_Pg104_12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Ground floor ---- etc., complete with all leadNo.1234.851234.8510.0FalseNoneNoneFalseNoneFalse12348.50
3373543118771NoneV2_Pg105_12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground floor ---- etc., complete with all leadNo.1278.61278.62.0FalseNoneNoneFalseNoneFalse2557.20
3373544118771NoneV2_Pg105_12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. Ground floor ---- etc., complete with all leadNo.1203.251203.2510.0FalseNoneNoneFalseNoneFalse12032.50
3373545118771NoneV2_Pg105_12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete Ground floor ---- etc., complete with all leadNo.288.05288.0520.0FalseNoneNoneFalseNoneFalse5761.00
3373546118771NoneV2_Pg105_12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete Ground floor ---- etc., complete with all leadNo.158.0158.020.0FalseNoneNoneFalseNoneFalse3160.00
3373547118771NoneV2_Pg105_12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms Ground floor ---- etc., complete with all leadNo.66.8566.8510.0FalseNoneNoneFalseNoneFalse668.50
3373548118771NoneV2_Pg107_12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) Ground floor ---- etc., complete with all leadNo.334.24334.2430.0FalseNoneNoneFalseNoneFalse10027.20
3373549118771NoneV2_Pg107_12.75.5Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 75x65x4 mm (heavy type) Ground floor ---- etc., complete with all leadNo.205.4205.46.0FalseNoneNoneFalseNoneFalse1232.40
3373550118771NoneV2_Pg69_10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Ground floor ---- etc., complete with all leadEach72.9272.9230.0FalseNoneNoneFalseNoneFalse2187.60
3373551118771NoneV2_A-25_447Providing & Fixing of Honne wood beading 10 mm wide corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. Ground floor ---- etc., complete with all leadm30.3930.3972.0FalseNoneNoneFalseNoneFalse2188.080
3373552118771NoneV2_Pg105_12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercial Ground floor ---- etc., complete with all leadSqm4245.394245.3920.01FalseNoneNoneFalseNoneFalse84950.25390
3373553118771NoneV2_Pg108_12.84PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size - 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground floor ---- etc., complete with all leadSqm6104.956104.9511.52FalseNoneNoneFalseNoneFalse70329.0240
3373554118771NoneV2_Pg109_12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground floor ---- etc., complete with all leadSqm6950.876950.870.72FalseNoneNoneFalseNoneFalse5004.62640
3373555118771NoneV2_Pg86_11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Ground floor ---- etc., complete with all leadKg204.19204.19220.32FalseNoneNoneFalseNoneFalse44987.14080
3373556118771NoneV2_Pg112_12.96Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame Ground floor ---- etc., complete with all leadm781.5781.59.9FalseNoneNoneFalseNoneFalse7736.850
3373557118771NoneV2_Pg112_12.97.1Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness Ground floor ---- etc., complete with all leadSqm3894.143894.143.15FalseNoneNoneFalseNoneFalse12266.5410
3373558118771NoneV2_Pg105_12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Ground floor ---- etc., complete with all leadNo.1353.961353.9610.0FalseNoneNoneFalseNoneFalse13539.60
3373559118771NoneV2_Pg41_8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For inside walls Ground floor ---- etc., complete with all leadSqm379.2379.2443.49FalseNoneNoneFalseNoneFalse168171.4080
3373560118771NoneV2_Pg50_8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground floor ---- etc., complete with all leadSqm121.54121.54443.49FalseNoneNoneFalseNoneFalse53901.77460
3373561118771NoneV2_Pg42_8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For external walls Ground floor ---- etc., complete with all leadSqm424.17424.17199.19FalseNoneNoneFalseNoneFalse84490.42230
3373562118771NoneV2_Pg43_8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide Ground floor ---- etc., complete with all leadm41.3241.32142.92FalseNoneNoneFalseNoneFalse5905.45440
3373563118771NoneV2_Pg54_8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Ground floor ---- etc., complete with all leadm80.2280.22142.92FalseNoneNoneFalseNoneFalse11465.04240
3373564118771NoneV2_Pg61_9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Ground floor ---- etc., complete with all leadSqm1428.11428.1107.22FalseNoneNoneFalseNoneFalse153120.8820
3373565118771NoneV2_Pg41_8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm358.54358.5417.85FalseNoneNoneFalseNoneFalse6399.9390
3373566118771NoneV2_Pg63_9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Ground floor ---- etc., complete with all leadSqm2997.182997.1815.89FalseNoneNoneFalseNoneFalse47625.19020
3373567118771NoneV2_Pg63_9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Ground floor ---- etc., complete with all leadSqm2997.182997.1811.88FalseNoneNoneFalseNoneFalse35606.49840
3373568118771NoneV2_Pg60_9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Ground floor ---- etc., complete with all leadSqm1080.491080.493.12FalseNoneNoneFalseNoneFalse3371.12880
3373569118771NoneV2_Pg65_9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Ground floor ---- etc., complete with all leadSqm1761.111761.1112.75FalseNoneNoneFalseNoneFalse22454.15250
3373570118771NoneV2_Pg48_8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm154.36154.36443.49FalseNoneNoneFalseNoneFalse68457.11640
3373571118771NoneV2_Pg46_8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm189.6189.6153.59FalseNoneNoneFalseNoneFalse29120.6640
3373572118771NoneV2_Pg47_8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm60.7760.7712.24FalseNoneNoneFalseNoneFalse743.82480
3373573118771NoneV2_Pg48_8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm139.77139.7750.07FalseNoneNoneFalseNoneFalse6998.28390
3373574118771NoneV2_Pg47_8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor ---- etc., complete with all leadSqm64.4264.4237.83FalseNoneNoneFalseNoneFalse2437.00860
3373575118771NoneV2_Pg83_11.25.1Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground floor ---- etc., complete with all leadKg137.34137.3483.6FalseNoneNoneFalseNoneFalse11481.6240
3373576118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Columns First Floor ---- etc., complete with all leadCum14280.2614280.265.32FalseNoneNoneFalseNoneFalse75970.98320
3373577118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Lintel beams First Floor ---- etc., complete with all leadCum13440.2413440.241.8FalseNoneNoneFalseNoneFalse24192.4320
3373578118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Chejjas First Floor ---- etc., complete with all leadCum12180.2212180.220.61FalseNoneNoneFalseNoneFalse7429.93420
3373579118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Roof beams First Floor ---- etc., complete with all leadCum13440.2413440.243.72FalseNoneNoneFalseNoneFalse49997.69280
3373580118771NoneV1_Pg16_2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including formwork For Roof slab First Floor ---- etc., complete with all leadCum12600.2312600.239.16FalseNoneNoneFalseNoneFalse115418.10680
3373581118771NoneV1_Pg16_2.1.4Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates including formwork For Cills First Floor ---- etc., complete with all leadCum11398.8211398.821.07FalseNoneNoneFalseNoneFalse12196.73740
3373582118771NoneV3_Pg135_15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ Epoxy First Floor ---- etc., complete with all leadNo250.42250.425.0FalseNoneNoneFalseNoneFalse1252.10
3373583118771NoneV1_Pg18_2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings First Floor ---- etc., complete with all leadt109813.3109813.31.85FalseNoneNoneFalseNoneFalse203154.6050
3373584118771NoneV2_Pg17_6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor ---- etc., complete with all leadSqm1608.11608.1163.43FalseNoneNoneFalseNoneFalse262811.7830
3373585118771NoneV2_Pg100_12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. First Floor ---- etc., complete with all leadSqm121300.75121300.750.13FalseNoneNoneFalseNoneFalse15769.09750
3373586118771NoneV2_Pg104_12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. First Floor ---- etc., complete with all leadNo1247.191247.193.0FalseNoneNoneFalseNoneFalse3741.570
3373587118771NoneV2_Pg105_12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. First Floor ---- etc., complete with all leadNo1291.391291.393.0FalseNoneNoneFalseNoneFalse3874.170
3373588118771NoneV2_Pg105_12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. First Floor ---- etc., complete with all leadNo1215.281215.283.0FalseNoneNoneFalseNoneFalse3645.840
3373589118771NoneV2_Pg105_12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete First Floor ---- etc., complete with all leadNo290.93290.936.0FalseNoneNoneFalseNoneFalse1745.580
3373590118771NoneV2_Pg105_12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete First Floor ---- etc., complete with all leadNo159.58159.586.0FalseNoneNoneFalseNoneFalse957.480
3373591118771NoneV2_Pg105_12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms First Floor ---- etc., complete with all leadNo67.5267.523.0FalseNoneNoneFalseNoneFalse202.560
3373592118771NoneV2_Pg107_12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) First Floor ---- etc., complete with all leadNo337.58337.589.0FalseNoneNoneFalseNoneFalse3038.220
3373593118771NoneV2_Pg107_12.75.5Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 75x65x4 mm (heavy type) First Floor ---- etc., complete with all leadNo207.46207.466.0FalseNoneNoneFalseNoneFalse1244.760
3373594118771NoneV2_Pg69_10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm First Floor ---- etc., complete with all leadNo73.6573.659.0FalseNoneNoneFalseNoneFalse662.850
3373595118771NoneV2_A25_447Providing & Fixing of Honne wood beading 10 mm wide corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. First Floor ---- etc., complete with all leadm30.6930.6957.6FalseNoneNoneFalseNoneFalse1767.7440
3373596118771NoneV2_Pg105_12.57.2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercial First Floor ---- etc., complete with all leadSqm4287.854287.855.9FalseNoneNoneFalseNoneFalse25298.3150
3373597118771NoneV2_Pg108_12.84PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size - 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor ---- etc., complete with all leadSqm6166.06166.09.36FalseNoneNoneFalseNoneFalse57713.760
3373598118771NoneV2_Pg109_12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor ---- etc., complete with all leadSqm7020.387020.380.98FalseNoneNoneFalseNoneFalse6879.97240
3373599118771NoneV2_Pg86_11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding First Floor ---- etc., complete with all leadKg206.23206.23186.12FalseNoneNoneFalseNoneFalse38383.52760
3373600118771NoneV2_Pg112_12.96Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame First Floor ---- etc., complete with all leadm789.32789.329.9FalseNoneNoneFalseNoneFalse7814.2680
3373601118771NoneV2_Pg112_12.97.1Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness First Floor ---- etc., complete with all leadSqm3933.083933.083.15FalseNoneNoneFalseNoneFalse12389.2020
3373602118771NoneV2_Pg105_12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. First Floor ---- etc., complete with all leadNo1367.51367.53.0FalseNoneNoneFalseNoneFalse4102.50
3373603118771NoneV2_Pg41_8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For inside walls First Floor ---- etc., complete with all leadSqm383.0383.0329.66FalseNoneNoneFalseNoneFalse126259.780
3373604118771NoneV2_Pg50_8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First Floor ---- etc., complete with all leadSqm122.76122.76329.66FalseNoneNoneFalseNoneFalse40469.06160
3373605118771NoneV2_Pg42_8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For external walls First Floor ---- etc., complete with all leadSqm428.42428.42235.51FalseNoneNoneFalseNoneFalse100897.19420
3373606118771NoneV2_Pg43_8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide First Floor ---- etc., complete with all leadm41.7441.74103.72FalseNoneNoneFalseNoneFalse4329.27280
3373607118771NoneV2_Pg54_8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. First Floor ---- etc., complete with all leadm81.0281.02103.72FalseNoneNoneFalseNoneFalse8403.39440
3373608118771NoneV2_Pg61_9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm First Floor ---- etc., complete with all leadSqm1442.381442.3868.8FalseNoneNoneFalseNoneFalse99235.7440
3373609118771NoneV2_Pg41_8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm362.13362.1313.35FalseNoneNoneFalseNoneFalse4834.43550
3373610118771NoneV2_Pg60_9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. First Floor ---- etc., complete with all leadSqm1091.31091.33.36FalseNoneNoneFalseNoneFalse3666.7680
3373611118771NoneV2_Pg65_9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor ---- etc., complete with all leadSqm1778.731778.7318.69FalseNoneNoneFalseNoneFalse33244.46370
3373612118771NoneV2_Pg48_8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm155.9155.9329.66FalseNoneNoneFalseNoneFalse51393.9940
3373613118771NoneV2_Pg46_8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm191.5191.5262.87FalseNoneNoneFalseNoneFalse50339.6050
3373614118771NoneV2_Pg47_8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm61.3861.3810.34FalseNoneNoneFalseNoneFalse634.66920
3373615118771NoneV2_Pg48_8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm141.17141.1723.26FalseNoneNoneFalseNoneFalse3283.61420
3373616118771NoneV2_Pg47_8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- etc., complete with all leadSqm65.0665.0612.92FalseNoneNoneFalseNoneFalse840.57520
3373617118771NoneV2_Pg149_15.1PProviding and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. First Floor ---- etc., complete with all leadSqm1002.911002.91122.12FalseNoneNoneFalseNoneFalse122475.36920
3373618118771NoneV2_Pg136_14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia Ground floor ---- etc., complete with all leadEach111.82111.824.0FalseNoneNoneFalseNoneFalse447.280
3373619118771NoneV5_Pg191_16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes Ground floor ---- etc., complete with all leadm168.94168.946.0FalseNoneNoneFalseNoneFalse1013.640
3373620118771NoneV2_Pg128_13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. 75mm nominal dia pipes Ground floor ---- etc., complete with all leadm351.25351.2514.0FalseNoneNoneFalseNoneFalse4917.50
3373621118771NoneV2_Pg128_13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. 110mm nominal dia pipes Ground floor ---- etc., complete with all leadm467.93467.936.0FalseNoneNoneFalseNoneFalse2807.580
3373622118771NoneV2_Pg125_13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter Ground floor ---- etc., complete with all leadm353.68353.689.0FalseNoneNoneFalseNoneFalse3183.120
3373623118771NoneV2_Pg131_14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Ground floor ---- etc., complete with all leadEach7264.457264.452.0FalseNoneNoneFalseNoneFalse14528.90
3373624118771NoneV2_Pg134_14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Ground floor ---- etc., complete with all leadEach6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3373625118771NoneV2_Pg117_13.3.2Providing and fixing brass stop cock of approved quality : 20 mm nominal bore Ground floor ---- etc., complete with all leadNo.370.7370.72.0FalseNoneNoneFalseNoneFalse741.40
3373626118771NoneV2_Pg124_14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps Ground floor ---- etc., complete with all leadEach3483.343483.342.0FalseNoneNoneFalseNoneFalse6966.680
3373627118771NoneV2_Pg122_13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Ground floor ---- etc., complete with all leadm460.64460.6420.0FalseNoneNoneFalseNoneFalse9212.80
3373628118771NoneV2_Pg122_13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes Ground floor ---- etc., complete with all leadm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3373629118771NoneV2_Pg122_13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes Ground floor ---- etc., complete with all leadm359.76359.7620.0FalseNoneNoneFalseNoneFalse7195.20
3373630118771NoneV5_Pg191_16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Ground floor ---- etc., complete with all leadEach6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3373631118771NoneV5_Pg191_16.1Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover Ground floor ---- etc., complete with all leadEach5148.435148.432.0FalseNoneNoneFalseNoneFalse10296.860
3373632118771NoneV2_Pg127_13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete Ground floor ---- etc., complete with all leadNo267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3373633118771NoneV2_Pg119_13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 Ground floor ---- etc., complete with all leadNo771.78771.782.0FalseNoneNoneFalseNoneFalse1543.560
3373634118771NoneV2_Pg136_14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia First floor ---- etc., complete with all leadEach112.93112.934.0FalseNoneNoneFalseNoneFalse451.720
3373635118771NoneV5_Pg191_16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes First floor ---- etc., complete with all leadm170.63170.636.0FalseNoneNoneFalseNoneFalse1023.780
3373636118771NoneV2_Pg128_13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. 75mm nominal dia pipes First floor ---- etc., complete with all leadm354.76354.764.0FalseNoneNoneFalseNoneFalse1419.040
3373637118771NoneV2_Pg128_13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. 110mm nominal dia pipes First floor ---- etc., complete with all leadm472.61472.615.0FalseNoneNoneFalseNoneFalse2363.050
3373638118771NoneV2_Pg125_13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter First floor ---- etc., complete with all leadm357.22357.223.5FalseNoneNoneFalseNoneFalse1250.270
3373639118771NoneV2_Pg131_14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid First floor ---- etc., complete with all leadEach7337.097337.092.0FalseNoneNoneFalseNoneFalse14674.180
3373640118771NoneV2_Pg117_13.3.2Providing and fixing brass stop cock of approved quality : 20 mm nominal bore First floor ---- etc., complete with all leadEach374.4374.42.0FalseNoneNoneFalseNoneFalse748.80
3373641118771NoneV2_Pg124_14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps First floor ---- etc., complete with all leadEach3518.173518.172.0FalseNoneNoneFalseNoneFalse7036.340
3373642118771NoneV2_Pg122_13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes First floor ---- etc., complete with all leadm465.24465.242.85FalseNoneNoneFalseNoneFalse1325.9340
3373643118771NoneV2_Pg122_13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes First floor ---- etc., complete with all leadm266.38266.3817.0FalseNoneNoneFalseNoneFalse4528.460
3373644118771NoneV2_Pg122_13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes First floor ---- etc., complete with all leadm471.58471.5820.0FalseNoneNoneFalseNoneFalse9431.60
3373645118771NoneV2_Pg117_13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore First floor ---- etc., complete with all leadNo779.07779.072.0FalseNoneNoneFalseNoneFalse1558.140
3373646118771NoneV2_Pg127_13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete First floor ---- etc., complete with all leadNo379.2379.22.0FalseNoneNoneFalseNoneFalse758.40
3373647118771NoneV2_Pg119_13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 First floor ---- etc., complete with all leadNo883.6883.62.0FalseNoneNoneFalseNoneFalse1767.20
3373648118771NoneV2_Pg123_13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. First floor ---- etc., complete with all leadl11.0511.051000.0FalseNoneNoneFalseNoneFalse11050.00
3373649118771NoneV6_2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3m from tapping point to out let via switch ---- etc., complete with all leadPoint269.0269.010.0FalseNoneNoneFalseNoneFalse2690.00
3373650118771NoneV6_2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m up to 6m from tapping point to out let via switch ---- etc., complete with all leadPoint379.0379.020.0FalseNoneNoneFalseNoneFalse7580.00
3373651118771NoneV6_2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m up to 10m from tapping point to out let via switch ---- etc., complete with all leadPoint555.0555.020.0FalseNoneNoneFalseNoneFalse11100.00
3373652118771NoneV6_3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way ---- etc., complete with all leadEach159.0159.010.0FalseNoneNoneFalseNoneFalse1590.00
3373653118771NoneV6_3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3373654118771NoneV6_3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach220.0220.04.0FalseNoneNoneFalseNoneFalse880.00
3373655118771NoneV6_3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all leadEach261.0261.010.0FalseNoneNoneFalseNoneFalse2610.00
3373656118771NoneV6_3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach319.0319.010.0FalseNoneNoneFalseNoneFalse3190.00
3373657118771NoneV6_3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach161.0161.010.0FalseNoneNoneFalseNoneFalse1610.00
3373658118771NoneV6_3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all leadEach175.0175.01.0FalseNoneNoneFalseNoneFalse175.00
3373659118771NoneV6_3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
3373660118771NoneV6_3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach284.0284.010.0FalseNoneNoneFalseNoneFalse2840.00
3373661118771NoneV6_3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3373662118771NoneV6_3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach102.0102.050.0FalseNoneNoneFalseNoneFalse5100.00
3373663118771NoneV6_3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach171.0171.030.0FalseNoneNoneFalseNoneFalse5130.00
3373664118771NoneV6_3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach357.0357.010.0FalseNoneNoneFalseNoneFalse3570.00
3373665118771NoneV6_3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
3373666118771NoneV6_3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
3373667118771NoneV6_3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all leadEach236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
3373668118771NoneV6_1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo117.0117.08.0FalseNoneNoneFalseNoneFalse936.00
3373669118771NoneV6_1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadm66.066.0100.0FalseNoneNoneFalseNoneFalse6600.00
3373670118771NoneV6_1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadm78.078.080.0FalseNoneNoneFalseNoneFalse6240.00
3373671118771NoneV6_1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadm103.0103.020.0FalseNoneNoneFalseNoneFalse2060.00
3373672118771NoneV6_1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadm68.068.080.0FalseNoneNoneFalseNoneFalse5440.00
3373673118771NoneV6_1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm79.079.050.0FalseNoneNoneFalseNoneFalse3950.00
3373674118771NoneV6_1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm99.099.010.0FalseNoneNoneFalseNoneFalse990.00
3373675118771NoneV6_2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm26.026.0200.0FalseNoneNoneFalseNoneFalse5200.00
3373676118771NoneV6_2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm42.042.0100.0FalseNoneNoneFalseNoneFalse4200.00
3373677118771NoneV6_2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm63.063.0300.0FalseNoneNoneFalseNoneFalse18900.00
3373678118771NoneV6_2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3373679118771NoneV6_5.19.4MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N ---- etc., complete with all leadEach1863.01863.01.0FalseNoneNoneFalseNoneFalse1863.00
3373680118771NoneV6_5.19.11MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TPN DB ---- etc., complete with all leadEach4038.04038.01.0FalseNoneNoneFalseNoneFalse4038.00
3373681118771NoneV6_5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach415.0415.010.0FalseNoneNoneFalseNoneFalse4150.00
3373682118771NoneV6_5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach811.0811.01.0FalseNoneNoneFalseNoneFalse811.00
3373683118771NoneV6_5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3373684118771NoneV6_5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole ---- etc., complete with all leadEach4277.04277.01.0FalseNoneNoneFalseNoneFalse4277.00
3373685118771NoneBSR-32.07LT UG CABLES 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all leadKm139549.0139549.00.1FalseNoneNoneFalseNoneFalse13954.90
3373686118771NoneBSR-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm16159.016159.00.1FalseNoneNoneFalseNoneFalse1615.90
3373687118771NoneSR 19-20 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia ---- etc., complete with all leadEach84.084.08.0FalseNoneNoneFalseNoneFalse672.00
3373688118771NoneV6_12.57EARTHING Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo4256.04256.02.0FalseNoneNoneFalseNoneFalse8512.00
3373689118771NoneSR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm75.075.010.0FalseNoneNoneFalseNoneFalse750.00
3373690118771NoneV6_11.3.2ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach690.0690.025.0FalseNoneNoneFalseNoneFalse17250.00
3373691118771NoneV6_11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach149.0149.04.0FalseNoneNoneFalseNoneFalse596.00
3373692118771NoneV6_12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach63.063.02.0FalseNoneNoneFalseNoneFalse126.00
3373693118771NoneV6_ 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ...........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- etc., complete with all leadNo4024.04024.01.0FalseNoneNoneFalseNoneFalse4024.00
3373694118771NoneV6_6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1492.01492.04.0FalseNoneNoneFalseNoneFalse5968.00
3373695118771NoneV6_6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach2984.02984.010.0FalseNoneNoneFalseNoneFalse29840.00
3373696118771NoneV6_13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach122.0122.030.0FalseNoneNoneFalseNoneFalse3660.00
3373697118771NoneV6_13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach315.0315.010.0FalseNoneNoneFalseNoneFalse3150.00
3373698118771NoneV6_13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach707.0707.04.0FalseNoneNoneFalseNoneFalse2828.00
3373699118771NoneV6_13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 m. Length ---- etc., complete with all leadEach1461.01461.01.0FalseNoneNoneFalseNoneFalse1461.00
3373700118771NoneV6_13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
3373701118771NoneV6_5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.430.4325000.0FalseNoneNoneFalseNoneFalse10750.00
3373702118771NoneV6_5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2465.02465.02.0FalseNoneNoneFalseNoneFalse4930.00
3373703118771NoneV6_5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm305.0305.04.0FalseNoneNoneFalseNoneFalse1220.00
3373704118771NoneV6_5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm756.0756.04.0FalseNoneNoneFalseNoneFalse3024.00
3373705118771NoneV6_5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 63A/100Amps 25kA FOUR POLE ---- etc., complete with all leadEach8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
3373706118771NoneV6_5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
3373707118771NoneV6_5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3373708118771NoneV6_5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPN ---- etc., complete with all leadEach3044.03044.01.0FalseNoneNoneFalseNoneFalse3044.00
3373709118771NoneV6_5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3088.03088.01.0FalseNoneNoneFalseNoneFalse3088.00
3373710118771NoneV6_5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3373711118771NoneV6_5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3373712118771NoneV6_5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all leadEach562.0562.03.0FalseNoneNoneFalseNoneFalse1686.00
3373713118771None197Preparation of detailed Structural designs and drawings including Soil exploration & proof checking and Providing consultancy for Architectural design and drawings floor wise. MEP design and drawings. Electrical services, Lift, Net Working, HVAC, Fire Fighting, Modular OT, interior layout and Providing consultancy services for water supply & sanitary, electrical drawings & any other related drawings to this work and liaison with other department and approval of pollution control board and allied works etc., - complete as per specification with all lead & lift and as per the directions of the Engineer-In-Charge of the work. ---- etc., complete with all leadJob41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
17194670000000NoneNoneBuildingsConstruction of Block Level Public Health Unit on First Floor at GH Gudibande in Chikkaballapura District.4930366.62
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3373714118772NoneV-2, Page-193, It.No-19.61Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum707.07707.0729.6FalseNoneNoneFalseNoneFalse20929.2720
3373715118772NoneV-2, Page-193, It.No-19.7.1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum591.68591.685.97FalseNoneNoneFalseNoneFalse3532.32960
3373716118772NoneV-3, Page-3, It.No-1.1 (a)Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all leadCum165.72165.7235.57FalseNoneNoneFalseNoneFalse5894.66040
3373717118772NoneV-1, Page-16, It.No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(RCC BEAMS)(LINTELS) ---- etc., complete with all leadCum13440.2413440.2413.29FalseNoneNoneFalseNoneFalse178620.78960
3373718118772NoneV-1, Page-16, It.No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJAS) ---- etc., complete with all leadCum12180.2212180.221.23FalseNoneNoneFalseNoneFalse14981.67060
3373719118772NoneV-1, Page-15, It.No-2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(Cill concrete) ---- etc., complete with all leadCum11065.9711065.978.06FalseNoneNoneFalseNoneFalse89191.71820
3373720118772NoneV-1, Page-84, It.No-2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadt109813.3109813.31.83FalseNoneNoneFalseNoneFalse200958.3390
3373721118772None18-19 SR, Page-15, It.No-4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadm38.9438.9446.5FalseNoneNoneFalseNoneFalse1810.710
3373722118772NoneV-2, Page-17, It.No-6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadCum1608.11608.1270.09FalseNoneNoneFalseNoneFalse434331.7290
3373723118772NoneV-2, Page-17, It.No-6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1355.221355.2218.42FalseNoneNoneFalseNoneFalse24963.15240
3373724118772NoneV-2, Page-100, It.No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum121300.75121300.750.51FalseNoneNoneFalseNoneFalse61863.38250
3373725118772NoneV-2, Page-104, It.No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1247.191247.1912.0FalseNoneNoneFalseNoneFalse14966.280
3373726118772NoneV-2, Page-105, It.No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1291.391291.3912.0FalseNoneNoneFalseNoneFalse15496.680
3373727118772NoneV-2, Page-105, It.No-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos1215.281215.2812.0FalseNoneNoneFalseNoneFalse14583.360
3373728118772NoneV-2, Page-105, It.No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos290.93290.9324.0FalseNoneNoneFalseNoneFalse6982.320
3373729118772NoneV-2, Page-105, It.No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos159.58159.5824.0FalseNoneNoneFalseNoneFalse3829.920
3373730118772NoneV-2, Page-105, It.No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos67.5267.5212.0FalseNoneNoneFalseNoneFalse810.240
3373731118772NoneV-2, Page-107, It.No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos337.58337.5824.0FalseNoneNoneFalseNoneFalse8101.920
3373732118772NoneV-2, Page-69, It.No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos73.6573.6572.0FalseNoneNoneFalseNoneFalse5302.80
3373733118772NoneV-2, Page-205, It.No-20.8Supplying and fixing new Honne wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm51.5651.5672.6FalseNoneNoneFalseNoneFalse3743.2560
3373734118772NoneV-2, Page-105, It.No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4077.934077.9329.52FalseNoneNoneFalseNoneFalse120380.49360
3373735118772NoneV-2, Page-110, It.No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8266.358266.3529.25FalseNoneNoneFalseNoneFalse241790.73750
3373736118772NoneV-2, Page-109, It.No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7020.387020.381.8FalseNoneNoneFalseNoneFalse12636.6840
3373737118772NoneV-2, Page-86, It.No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg206.23206.23652.05FalseNoneNoneFalseNoneFalse134472.27150
3373738118772NoneV-2, Page-111, It.No-12.93.2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fastenersof required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm ---- etc., complete with all leadm861.74861.749.9FalseNoneNoneFalseNoneFalse8531.2260
3373739118772NoneV-2, Page-112, It.No-12.94.2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness ---- etc., complete with all leadSqm4960.554960.553.15FalseNoneNoneFalseNoneFalse15625.73250
3373740118772NoneV-2, Page-107, It.No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1367.51367.59.0FalseNoneNoneFalseNoneFalse12307.50
3373741118772NoneV-2, Page-109, It.No-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKgs166.95166.9588.2FalseNoneNoneFalseNoneFalse14724.990
3373742118772NoneV-2, Page-86, It.No-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg554.85554.8543.2FalseNoneNoneFalseNoneFalse23969.520
3373743118772NoneV-2, Page-89, It.No-11.37.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm1212.821212.824.32FalseNoneNoneFalseNoneFalse5239.38240
3373744118772NoneV-2, Page-41, It.No-8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm383.0383.0415.32FalseNoneNoneFalseNoneFalse159067.560
3373745118772NoneV-2, Page-50, It.No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm122.76122.76415.32FalseNoneNoneFalseNoneFalse50984.68320
3373746118772NoneV-2, Page-42, It.No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm428.42428.42126.53FalseNoneNoneFalseNoneFalse54207.98260
3373747118772None118, Page-V-2, It.No-8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment) Plaster mesh 150mm wide ---- etc., complete with all leadm46.6546.65440.88FalseNoneNoneFalseNoneFalse20567.0520
3373748118772None70, Page-18-19 SR, It.No-10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm254.88254.8810.0FalseNoneNoneFalseNoneFalse2548.80
3373749118772NoneV-2, Page-54, It.No-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.8363.83123.9FalseNoneNoneFalseNoneFalse7908.5370
3373750118772NoneV-2, Page-61, It.No-9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm ---- etc., complete with all leadSqm1442.381442.38129.25FalseNoneNoneFalseNoneFalse186427.6150
3373751118772NoneV-2, Page-41, It.No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm362.13362.1372.98FalseNoneNoneFalseNoneFalse26428.24740
3373752118772NoneV-2, Page-63, It.No-9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent ---- etc., complete with all leadSqm3027.153027.1545.8FalseNoneNoneFalseNoneFalse138643.470
3373753118772NoneV-2, Page-63, It.No-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm3500.983500.9815.23FalseNoneNoneFalseNoneFalse53319.92540
3373754118772NoneV-2, Page-134, It.No-15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm754.95754.956.96FalseNoneNoneFalseNoneFalse5254.4520
3373755118772NoneV-2, Page-60, It.No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1091.31091.36.96FalseNoneNoneFalseNoneFalse7595.4480
3373756118772NoneV-2, Page-65, It.No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1778.731778.7372.98FalseNoneNoneFalseNoneFalse129811.71540
3373757118772NoneV-2, Page-48, It.No-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm155.9155.9415.32FalseNoneNoneFalseNoneFalse64748.3880
3373758118772NoneV-2, Page-45, It.No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm191.5191.5276.53FalseNoneNoneFalseNoneFalse52955.4950
3373759118772NoneV-2, Page-47, It.No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm61.3861.3831.05FalseNoneNoneFalseNoneFalse1905.8490
3373760118772NoneV-2, Page-48, It.No-8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm141.17141.1731.05FalseNoneNoneFalseNoneFalse4383.32850
3373761118772NoneV-2, Page-47, It.No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm65.0665.0659.04FalseNoneNoneFalseNoneFalse3841.14240
3373762118772NoneV-2, Page-49, It.No-8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm165.72165.7259.04FalseNoneNoneFalseNoneFalse9784.10880
3373763118772NoneV-2, Page-38, It.No-7.67.2Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work.50mm thickness ---- etc., complete with all leadSqm3185.53185.5197.3FalseNoneNoneFalseNoneFalse628499.150
3373764118772NoneV-2, Page-82, It.No-11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg166.95166.953500.0FalseNoneNoneFalseNoneFalse584325.00
3373765118772NoneV-2, Page-23, It.No-7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all leadCum2475.982475.9816.28FalseNoneNoneFalseNoneFalse40308.95440
3373766118772NoneV-2, Page-23, It.No-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg693.57693.5716.5FalseNoneNoneFalseNoneFalse11443.9050
3373767118772NoneJobPreparation of detailed Structural designs and drawings including Soil exploration & proof checking and Providing consultancy for Architectural design and drawings floor wise. MEP design and drawings. Electrical services, Lift, Net Working, HVAC, Fire Fighting, Modular OT, interior layout and Providing consultancy services for water supply & sanitary, electrical drawings & any other related drawings to this work and liaison with other department and approval of pollution control board and allied works etc., -- complete as per specification with all lead & lift and as per the directions of the Engineer-In-Charge of the work. ---- etc., complete with all leadJob41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3373768118772NoneV-2, Page-136, It.No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete-40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach112.9112.98.0FalseNoneNoneFalseNoneFalse903.20
3373769118772NoneV-5, Page-191, It.No-16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: ---- etc., complete with all leadm170.58170.5825.0FalseNoneNoneFalseNoneFalse4264.50
3373770118772NoneV-5, Page-A-44, It.No-657PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- etc., complete with all leadm150.95150.9575.0FalseNoneNoneFalseNoneFalse11321.250
3373771118772NoneV-5, Page-A-44, It.No-647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm312.94312.9450.0FalseNoneNoneFalseNoneFalse15647.00
3373772118772NoneV-2, Page-125, It.No-13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm241.76241.7620.0FalseNoneNoneFalseNoneFalse4835.20
3373773118772NoneV-2, Page-136, It.No-14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1497.181497.184.0FalseNoneNoneFalseNoneFalse5988.720
3373774118772NoneV-2, Page-131, It.No-14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadNo7334.977334.972.0FalseNoneNoneFalseNoneFalse14669.940
3373775118772NoneV-2, Page-126, It.No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos.6236.636236.636.0FalseNoneNoneFalseNoneFalse37419.780
3373776118772NoneV-2, Page-119, It.No-13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos.889.72889.7210.0FalseNoneNoneFalseNoneFalse8897.20
3373777118772NoneV-2, Page-124, It.No-14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3782.233782.232.0FalseNoneNoneFalseNoneFalse7564.460
3373778118772NoneV-2, Page-120, It.No-13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc-15 mm nominal dia Pipes ---- etc., complete with all leadm379.2379.250.0FalseNoneNoneFalseNoneFalse18960.00
3373779118772NoneV-2, Page-120, It.No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20 mm nominal dia Pipes ---- etc., complete with all leadm465.11465.11100.0FalseNoneNoneFalseNoneFalse46511.00
3373780118772NoneV-2, Page-120, It.No-13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)-20 mm nominal dia Pipes ---- etc., complete with all leadm266.3266.350.0FalseNoneNoneFalseNoneFalse13315.00
3373781118772NoneV-2, Page-120, It.No-13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)-25 mm nominal dia Pipes ---- etc., complete with all leadm363.25363.2550.0FalseNoneNoneFalseNoneFalse18162.50
3373782118772NoneV-5, Page-162, It.No-16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadNos.6628.796628.795.0FalseNoneNoneFalseNoneFalse33143.950
3373783118772NoneV-2, Page-127, It.No-13.58Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadNos.424.61424.6110.0FalseNoneNoneFalseNoneFalse4246.10
3373784118772NoneV-2, Page-123, It.No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl11.0411.041000.0FalseNoneNoneFalseNoneFalse11040.00
3373785118772NoneV-2, Page-123, It.No-14.95 aProviding and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium ---- etc., complete with all leadNos.1251.741251.742.0FalseNoneNoneFalseNoneFalse2503.480
3373786118772NoneV-6, Page-5, It.No-2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Short point up to 3m from tapping point to out let via switch ---- etc., complete with all leadPoint326.94326.9415.0FalseNoneNoneFalseNoneFalse4904.10
3373787118772NoneV-6, Page-5, It.No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Medium point above 3m up to 6m from tapping point to out let via switch ---- etc., complete with all leadPoint460.64460.6430.0FalseNoneNoneFalseNoneFalse13819.20
3373788118772NoneV-6, Page-5, It.No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Long point above 6m up to 10m from tapping point to out let via switch ---- etc., complete with all leadPoint674.55674.5520.0FalseNoneNoneFalseNoneFalse13491.00
3373789118772NoneV-6, Page-5, It.No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Two outlet in a row, above 3m up to 6m from tapping point to out let via switches ---- etc., complete with all leadPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3373790118772NoneV-6, Page-8, It.No-3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-2Way ---- etc., complete with all leadEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
3373791118772NoneV-6, Page-8, It.No-3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3 Way ---- etc., complete with all leadEach193.25193.2510.0FalseNoneNoneFalseNoneFalse1932.50
3373792118772NoneV-6, Page-8, It.No-3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-4-5Way ---- etc., complete with all leadEach215.13215.138.0FalseNoneNoneFalseNoneFalse1721.040
3373793118772NoneV-6, Page-8, It.No-3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-6Way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
3373794118772NoneV-6, Page-8, It.No-3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-8 Way ---- etc., complete with all leadEach317.22317.225.0FalseNoneNoneFalseNoneFalse1586.10
3373795118772NoneV-6, Page-8, It.No-3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10-12Way ---- etc., complete with all leadEach387.71387.7122.0FalseNoneNoneFalseNoneFalse8529.620
3373796118772NoneV-6, Page-8, It.No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1 to 2 Module ---- etc., complete with all leadEach166.51166.5110.0FalseNoneNoneFalseNoneFalse1665.10
3373797118772NoneV-6, Page-8, It.No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-3 Module ---- etc., complete with all leadEach195.68195.6810.0FalseNoneNoneFalseNoneFalse1956.80
3373798118772NoneV-6, Page-8, It.No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-4 Module ---- etc., complete with all leadEach212.7212.78.0FalseNoneNoneFalseNoneFalse1701.60
3373799118772NoneV-6, Page-8, It.No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6 Module ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
3373800118772NoneV-6, Page-8, It.No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8 Module ---- etc., complete with all leadEach345.17345.175.0FalseNoneNoneFalseNoneFalse1725.850
3373801118772NoneV-6, Page-8, It.No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-10-12 Module ---- etc., complete with all leadEach418.1418.122.0FalseNoneNoneFalseNoneFalse9198.20
3373802118772NoneV-6, Page-9, It.No-3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps one way Switch ---- etc., complete with all leadEach123.97123.97120.0FalseNoneNoneFalseNoneFalse14876.40
3373803118772NoneV-6, Page-9, It.No-3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps 3way socket ---- etc., complete with all leadEach207.83207.8330.0FalseNoneNoneFalseNoneFalse6234.90
3373804118772NoneV-6, Page-9, It.No-3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.910.0FalseNoneNoneFalseNoneFalse4339.00
3373805118772NoneV-6, Page-9, It.No-3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-16Amps one way switch ---- etc., complete with all leadEach218.77218.7710.0FalseNoneNoneFalseNoneFalse2187.70
3373806118772NoneV-6, Page-9, It.No-3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32Amps DP switch ---- etc., complete with all leadEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3373807118772NoneV-6, Page-9, It.No-3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293-6/16Amps universal socket ---- etc., complete with all leadEach286.83286.8320.0FalseNoneNoneFalseNoneFalse5736.60
3373808118772NoneV-6, Page-4, It.No-1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3373809118772NoneV-6, Page-2, It.No-1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-19/20mm dia 2mm thick ---- etc., complete with all leadm80.2280.22300.0FalseNoneNoneFalseNoneFalse24066.00
3373810118772NoneV-6, Page-2, It.No-1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-25mm dia 2mm thick ---- etc., complete with all leadm94.894.8350.0FalseNoneNoneFalseNoneFalse33180.00
3373811118772NoneV-6, Page-2, It.No-1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-32mm dia 2.5mm thick ---- etc., complete with all leadm125.19125.19100.0FalseNoneNoneFalseNoneFalse12519.00
3373812118772NoneV-6, Page-2, It.No-1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-19/20mm dia 2mm thick ---- etc., complete with all leadm82.6582.65150.0FalseNoneNoneFalseNoneFalse12397.50
3373813118772NoneV-6, Page-2, It.No-1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3373814118772NoneV-6, Page-2, It.No-1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3230.0FalseNoneNoneFalseNoneFalse3609.60
3373815118772NoneV-6, Page-5, It.No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-1.5 sqmm ---- etc., complete with all leadm31.631.6300.0FalseNoneNoneFalseNoneFalse9480.00
3373816118772NoneV-6, Page-5, It.No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-2.5 sqmm ---- etc., complete with all leadm51.0551.05900.0FalseNoneNoneFalseNoneFalse45945.00
3373817118772NoneV-6, Page-5, It.No-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-4 sqmm ---- etc., complete with all leadm76.5776.57250.0FalseNoneNoneFalseNoneFalse19142.50
3373818118772NoneV-6, Page-5, It.No-2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-6 sqmm ---- etc., complete with all leadm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3373819118772NoneV-6, Page-18, It.No-5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door-12 Way SP & N ---- etc., complete with all leadEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3373820118772NoneV-6, Page-18, It.No-5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door-4 Way TPN DB ---- etc., complete with all leadEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3373821118772NoneV-6, Page-18, It.No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32Amps SP ---- etc., complete with all leadEach504.39504.3920.0FalseNoneNoneFalseNoneFalse10087.80
3373822118772NoneV-6, Page-18, It.No-5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-50-63Amps TPN ---- etc., complete with all leadEach985.69985.691.0FalseNoneNoneFalseNoneFalse985.690
3373823118772NoneV-6, Page-18, It.No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32Amps DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3373824118772NoneV-6, Page-18, It.No-5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5198.275198.271.0FalseNoneNoneFalseNoneFalse5198.270
3373825118772NoneV-6, Page-13, It.No-32.07LT UG CABLES 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-3.5 core 25 sqmm ---- etc., complete with all leadKm169607.85169607.850.1FalseNoneNoneFalseNoneFalse16960.7850
3373826118772NoneV-6, Page-52, It.No-BSR-21.05LT UG CABLES Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm24645.4824645.480.1FalseNoneNoneFalseNoneFalse2464.5480
3373827118772NonePage-42, It.No-SR 19-20 6.11.2LT UG CABLES Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)25mm dia ---- etc., complete with all leadEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3373828118772NoneV-6, Page-54, It.No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. EARTHING ---- etc., complete with all leadNo4897.04897.02.0FalseNoneNoneFalseNoneFalse9794.00
3373829118772NonePage-40, It.No-SR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.EARTHING-25x3mm GI strip ---- etc., complete with all leadm88.588.515.0FalseNoneNoneFalseNoneFalse1327.50
3373830118772NoneV-6, Page-43, It.No-11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI - 80. Power Input: 220-240V @ 50/60Hz & Power factor -0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6330.0FalseNoneNoneFalseNoneFalse25158.90
3373831118772NoneV-6, Page-47, It.No-11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI-70%. efficacy -80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF - 0.95, power loss should - 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.7 W, 6500K ---- etc., complete with all leadEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3373832118772NoneV-6, Page-52, It.No-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach76.5776.574.0FalseNoneNoneFalseNoneFalse306.280
3373833118772NoneV-6, Page-46, It.No-11.8(40757)Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT - 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire - IK08. Power Factor -0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency-130lm/w, nominal CRI -75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- etc., complete with all leadNo4890.774890.771.0FalseNoneNoneFalseNoneFalse4890.770
3373834118772NoneV-6, Page-30, It.No-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.383.0FalseNoneNoneFalseNoneFalse5440.140
3373835118772NoneV-6, Page-30, It.No-6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.7512.0FalseNoneNoneFalseNoneFalse43521.00
3373836118772NoneV-6, Page-56, It.No-13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2834.0FalseNoneNoneFalseNoneFalse5041.520
3373837118772NoneV-6, Page-57, It.No-13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach382.85382.8512.0FalseNoneNoneFalseNoneFalse4594.20
3373838118772NoneV-6, Page-57, It.No-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.29859.293.0FalseNoneNoneFalseNoneFalse2577.870
3373839118772NoneV-6, Page-56, It.No-13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories.Single bracket 1.5 m. Length ---- etc., complete with all leadEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3373840118772NoneV-6, Page-56, It.No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3373841118772NoneV-6, Page-20, It.No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete-16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3373842118772NoneV-6, Page-20, It.No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.962.0FalseNoneNoneFalseNoneFalse5991.920
3373843118772NoneV-6, Page-20, It.No-5.41.1Supplying and fixing angle iron frame work fabbricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm370.7370.78.0FalseNoneNoneFalseNoneFalse2965.60
3373844118772NoneV-6, Page-20, It.No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint-50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.848.0FalseNoneNoneFalseNoneFalse7350.720
3373845118772NoneV-6, Page-17, It.No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE-63A/100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3373846118772NoneV-6, Page-17, It.No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3373847118772NoneV-6, Page-17, It.No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3373848118772NoneV-6, Page-17, It.No-5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPN ---- etc., complete with all leadEach3699.683699.682.0FalseNoneNoneFalseNoneFalse7399.360
3373849118772NoneV-6, Page-18, It.No-5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3373850118772NoneV-6, Page-19, It.No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3373851118772NoneV-6, Page-19, It.No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3373852118772NoneV-6, Page-19, It.No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
3373853118772NoneV-6, Page-19, It.No-5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter UPS ---- etc., complete with all leadEach6228.936228.931.0FalseNoneNoneFalseNoneFalse6228.930
3373854118772NoneV-6, Page-38, It.No-9.3.2Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPS ---- etc., complete with all leadEach58306.3858306.381.0FalseNoneNoneFalseNoneFalse58306.380
3373855118772NoneV-6, Page-38, It.No-9.5.3Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 26 AH capacity ---- etc., complete with all leadEach5469.35469.316.0FalseNoneNoneFalseNoneFalse87508.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194670010000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194670010001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17194670010001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17194670010000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194670010000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194670610000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17194670690000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17194670770000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194670850000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17194670930000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17194671010000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17194671260000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17194671450000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17194671540000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17194671640000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17194671740000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17194671840000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17194671920000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17194672010000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17194672110000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17194672210000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17194672300000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17194672390000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17194672470000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs. 74.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1) Earthwork Excavation /Embankment 475.00 Cum 2) RCC and PCC 172.00 Cum 3) Steel Reinforcement for RCC work 13.00 Tonnes 4)Cement Concrete Block Masonry/Solid Block Masonry 690.00 Sqm 5) Flooring / Dadooing (Vitrified/Granite/Ceramic/Cement concrete/cladding 570.00 Sqm, 6)Plastering 1430.00 Sqm, 7)Painting 2365.00 Sqm Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.8.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.2.50 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Class-III and above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1) Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 One, 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 One.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.2(a):The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 297.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.45.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by a Scheduled/ Nationalized Bank
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level of existing commitments and ongoing works to be completed during the next 06 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing commitments and Bids submitted for the works certificate issued by the officer not less than the rank of Executive Engineer
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate issued by Chartered AccountantTrueTechnical Bid
Company Registration Certificate issued by KPWDTrueTechnical Bid
ESI & PF Registration certificatesTrueTechnical Bid
Work done certificatesTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsKolarSrinivasapuraKolarSRINIVASAPURIn premises of General Hospital (TLH) Srinivasapura.NoneNoneNoneNoneNoneNone
BuildingsKolarBangarapeteKolarBANAGARAPETEIn premises of General Hospital (TLH) Bangarpete.NoneNoneNoneNoneNoneNone
BuildingsChikkaballapuraGudibandaChikballapurCHIKBALLAPUR (SC)On First Floor at General Hospital(TLH), GudibandeNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1719470822000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone