| 1719494785000 | 0 | None | None | Water supply/sewage lines | LAYING OF UGD LINE AND CONSTRUCTION OF UGD CHAMBERS FROM NAGARBAUDI WELL TO SHEDJI MALLA ROAD IN WARD NO.24 IN VIJAYAPUR CITY. | 808946.96 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3390341 | 119412 | None | Volum-5 Sl No-10.1.1-113 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 275.1 | 275.1 | 219.1499 | False | None | None | False | None | False | 60288.13749 | 0 | | 3390342 | 119412 | None | 16.1.4-187 | Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.230 mm dia. pipes | Mtr | 926.1 | 926.1 | 206.0 | False | None | None | False | None | False | 190776.6 | 0 | | 3390343 | 119412 | None | 16.40.10-201 | Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving achinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With able Moulded Bricks & Medium Duty cover and frame.For 1.2m dia(Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.20 M depth & Medium duty SFRC cover & frame) | Each | 30208.71 | 30208.71 | 2.0 | False | None | None | False | None | False | 60417.42 | 0 | | 3390344 | 119412 | None | 16.40.10-201 | Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving achinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With able Moulded Bricks & Medium Duty cover and frame.For 1.2m dia(Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.30 M depth & Medium duty SFRC cover & frame) | Set | 32529.84 | 32529.84 | 2.0 | False | None | None | False | None | False | 65059.68 | 0 | | 3390345 | 119412 | None | 16.40.10-201 | Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving achinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With able Moulded Bricks & Medium Duty cover and frame.For 1.2m dia(Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.40 M depth & Medium duty SFRC cover & frame) | Each | 34850.97 | 34850.97 | 2.0 | False | None | None | False | None | False | 69701.94 | 0 | | 3390346 | 119412 | None | 16.40.10-201 | Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving achinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With able Moulded Bricks & Medium Duty cover and frame.For 1.2m dia(Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.50 M depth & Medium duty SFRC cover & frame) | Each | 37172.1 | 37172.1 | 2.0 | False | None | None | False | None | False | 74344.2 | 0 | | 3390347 | 119412 | None | 16.40.10-201 | Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving achinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With able Moulded Bricks & Medium Duty cover and frame.For 1.2m dia(Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.60 M depth & Medium duty SFRC cover & frame) | Set | 39493.22 | 39493.22 | 2.0 | False | None | None | False | None | False | 78986.44 | 0 | | 3390348 | 119412 | None | 1.10-7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 219.1499 | False | None | None | False | None | False | 36817.1832 | 0 | | 3390349 | 119412 | None | Volum-5, Sl No-10.2.2-113 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: M020B Pipes of SN4, 110mm dia | Mtr | 302.4 | 302.4 | 100.0 | False | None | None | False | None | False | 30240.0 | 0 | | 3390350 | 119412 | None | Volum-5 Sl No-10.1.1-113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: | Mtr | 50.4 | 50.4 | 100.0 | False | None | None | False | None | False | 5040.0 | 0 | | 3390351 | 119412 | None | PWD SR Valum-5 , Sl No-16.28.1, page no 198 | Repairs to Machinehole for different depths including removal of debris, levelling the brick masonry, construction of brick masonry upto Ground level, providing CC coping alround the MH cover, plastering both inside and outside to the brick masonry and fixing of manhole frame and cover, curing, refilling with appurtenances complete. (0.30mtr ) T461A | Each | 8577.45 | 8577.45 | 10.0 | False | None | None | False | None | False | 85774.5 | 0 | | 3390352 | 119412 | None | PWD SR Vol-5 , Sl No-16.23.2, page no 196 | Supplying and fixing SFRC frame and cover conforming to IS 12592 (part I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete(PWD SR Valum-5 , Sl No-22.2, page no 192 ) with heavy duty | Set | 2692.2 | 2692.2 | 12.0 | False | None | None | False | None | False | 32306.4 | 0 | | 3390353 | 119412 | None | Volum-3, SlNo-3.6,P.No-17 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 37.08 | False | None | None | False | None | False | 19194.462 | 0 |
|