createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719490205239
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd549000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 16:00:00
tenderQueryClose03-07-2024 16:00:00
technicalBidOpen12-07-2024 16:30:00
publishedDate27-06-2024 18:24:38
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate04-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1719490205270
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT496
titleConstruction of Health and Wellness centre at 1) Gudenkatti in Kundagol Tq, 2) Hultikoti in Dharwad Tq, 3) Hulikeri in Alnavar Tq, 4) Neeralakatti in Dharwad Tq, 5) Mummigatti in Dharwad Tq, 6) Belavantar in Kalaghatagi Tq, Dharwad District.
descriptionConstruction of Health and Wellness centre at 1) Gudenkatti in Kundagol Tq, 2) Hultikoti in Dharwad Tq, 3) Hulikeri in Alnavar Tq, 4) Neeralakatti in Dharwad Tq, 5) Mummigatti in Dharwad Tq, 6) Belavantar in Kalaghatagi Tq, Dharwad District.
categoryWORKS
categoryTextWorks
ecv36599307.06
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount36600000.0
groupOverheadTotalNone
fileNumberhfw/eng/subdvn/dwd-24/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194902050000NoneNoneBuildingsGudenkatti HWC GF Civil Work Slice-13603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388032119313NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3388033119313NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3388034119313NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3388035119313NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3388036119313NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3388037119313NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3388038119313NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3388039119313NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3388040119313NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3388041119313NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3388042119313NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3388043119313NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3388044119313NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3388045119313NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3388046119313NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3388047119313NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3388048119313NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3388049119313NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3388050119313NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3388051119313NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3388052119313NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3388053119313NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3388054119313NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3388055119313NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3388056119313NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3388057119313NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3388058119313NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3388059119313NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3388060119313NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3388061119313NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3388062119313NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3388063119313NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3388064119313NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3388065119313NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3388066119313NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3388067119313NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3388068119313NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3388069119313NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3388070119313NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3388071119313NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3388072119313NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3388073119313NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3388074119313NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3388075119313NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3388076119313NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3388077119313NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3388078119313NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3388079119313NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3388080119313NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3388081119313NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3388082119313NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3388083119313NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3388084119313NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3388085119313NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3388086119313NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902050000NoneNoneBuildingsGudenkatti HWC FF Civil Work SLICE-11866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388087119314NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3388088119314NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3388089119314NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3388090119314NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3388091119314NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3388092119314NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3388093119314NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3388094119314NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3388095119314NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3388096119314NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3388097119314NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3388098119314NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3388099119314NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3388100119314NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3388101119314NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3388102119314NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3388103119314NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3388104119314NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3388105119314NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3388106119314NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3388107119314NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3388108119314NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3388109119314NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3388110119314NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3388111119314NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3388112119314NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3388113119314NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3388114119314NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3388115119314NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3388116119314NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3388117119314NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3388118119314NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3388119119314NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3388120119314NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3388121119314NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3388122119314NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3388123119314NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3388124119314NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3388125119314NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3388126119314NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3388127119314NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3388128119314NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902050000NoneNoneBuildingsGudenkatti HWC WS Work SLICE-1254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388129119315NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3388130119315NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3388131119315NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3388132119315NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3388133119315NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3388134119315NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3388135119315NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3388136119315NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3388137119315NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3388138119315NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3388139119315NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3388140119315NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3388141119315NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3388142119315NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3388143119315NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3388144119315NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3388145119315NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3388146119315NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3388147119315NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3388148119315NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3388149119315NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3388150119315NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3388151119315NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3388152119315NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3388153119315NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3388154119315NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3388155119315NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3388156119315NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3388157119315NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3388158119315NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3388159119315NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3388160119315NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3388161119315NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3388162119315NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902050000NoneNoneBuildingsGudenkatti HWC Electrical Work SLICE-1375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388163119316NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3388164119316NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3388165119316NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3388166119316NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3388167119316NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3388168119316NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388169119316NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3388170119316NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3388171119316NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3388172119316NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3388173119316NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3388174119316NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3388175119316NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3388176119316NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3388177119316NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3388178119316NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3388179119316NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3388180119316NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3388181119316NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388182119316NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3388183119316NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3388184119316NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3388185119316NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3388186119316NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3388187119316NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3388188119316NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3388189119316NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3388190119316NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3388191119316NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3388192119316NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3388193119316NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3388194119316NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3388195119316NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3388196119316NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3388197119316NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3388198119316NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3388199119316NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3388200119316NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3388201119316NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3388202119316NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3388203119316NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3388204119316NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3388205119316NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3388206119316NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3388207119316NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3388208119316NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3388209119316NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3388210119316NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3388211119316NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3388212119316NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3388213119316NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3388214119316None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388215119316NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3388216119316NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3388217119316NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3388218119316NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3388219119316NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388220119316NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3388221119316NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3388222119316NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3388223119316NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3388224119316NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3388225119316NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3388226119316NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3388227119316NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3388228119316NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3388229119316NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3388230119316NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3388231119316NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3388232119316NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
17194902050000NoneNoneBuildingsHultikoti HWC GF Civil Work SLICE-23603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388233119317NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3388234119317NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3388235119317NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3388236119317NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3388237119317NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3388238119317NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3388239119317NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3388240119317NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3388241119317NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3388242119317NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3388243119317NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3388244119317NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3388245119317NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3388246119317NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3388247119317NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3388248119317NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3388249119317NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3388250119317NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3388251119317NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3388252119317NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3388253119317NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3388254119317NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3388255119317NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3388256119317NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3388257119317NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3388258119317NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3388259119317NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3388260119317NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3388261119317NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3388262119317NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3388263119317NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3388264119317NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3388265119317NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3388266119317NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3388267119317NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3388268119317NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3388269119317NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3388270119317NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3388271119317NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3388272119317NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3388273119317NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3388274119317NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3388275119317NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3388276119317NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3388277119317NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3388278119317NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3388279119317NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3388280119317NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3388281119317NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3388282119317NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3388283119317NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3388284119317NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3388285119317NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3388286119317NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3388287119317NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902050000NoneNoneBuildingsHultikoti HWC FF Civil Work SLICE-21866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388288119318NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3388289119318NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3388290119318NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3388291119318NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3388292119318NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3388293119318NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3388294119318NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3388295119318NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3388296119318NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3388297119318NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3388298119318NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3388299119318NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3388300119318NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3388301119318NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3388302119318NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3388303119318NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3388304119318NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3388305119318NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3388306119318NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3388307119318NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3388308119318NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3388309119318NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3388310119318NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3388311119318NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3388312119318NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3388313119318NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3388314119318NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3388315119318NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3388316119318NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3388317119318NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3388318119318NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3388319119318NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3388320119318NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3388321119318NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3388322119318NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3388323119318NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3388324119318NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3388325119318NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3388326119318NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3388327119318NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3388328119318NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3388329119318NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902050000NoneNoneBuildingsHultikoti HWC WS Work SLICE-2254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388330119319NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3388331119319NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3388332119319NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3388333119319NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3388334119319NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3388335119319NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3388336119319NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3388337119319NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3388338119319NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3388339119319NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3388340119319NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3388341119319NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3388342119319NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3388343119319NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3388344119319NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3388345119319NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3388346119319NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3388347119319NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3388348119319NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3388349119319NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3388350119319NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3388351119319NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3388352119319NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3388353119319NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3388354119319NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3388355119319NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3388356119319NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3388357119319NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3388358119319NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3388359119319NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3388360119319NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3388361119319NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3388362119319NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3388363119319NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902050000NoneNoneBuildingsHultikoti HWC Electrical Work SLICE-2375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388364119320NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3388365119320NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3388366119320NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3388367119320NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3388368119320NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3388369119320NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388370119320NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3388371119320NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3388372119320NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3388373119320NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3388374119320NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3388375119320NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3388376119320NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3388377119320NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3388378119320NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3388379119320NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3388380119320NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3388381119320NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3388382119320NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388383119320NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3388384119320NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3388385119320NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3388386119320NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3388387119320NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3388388119320NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3388389119320NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3388390119320NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3388391119320NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3388392119320NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3388393119320NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3388394119320NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3388395119320NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3388396119320NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3388397119320NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3388398119320NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3388399119320NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3388400119320NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3388401119320NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3388402119320NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3388403119320NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3388404119320NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3388405119320NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3388406119320NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3388407119320NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3388408119320NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3388409119320NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3388410119320NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3388411119320NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3388412119320NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3388413119320NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3388414119320NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3388415119320None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388416119320NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3388417119320NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3388418119320NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3388419119320NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3388420119320NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388421119320NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3388422119320NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3388423119320NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3388424119320NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3388425119320NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3388426119320NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3388427119320NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3388428119320NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3388429119320NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3388430119320NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3388431119320NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3388432119320NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3388433119320NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
17194902050000NoneNoneBuildingsHulikeri HWC GF Civil Work SLICE-33603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388434119321NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3388435119321NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3388436119321NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3388437119321NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3388438119321NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3388439119321NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3388440119321NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3388441119321NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3388442119321NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3388443119321NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3388444119321NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3388445119321NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3388446119321NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3388447119321NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3388448119321NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3388449119321NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3388450119321NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3388451119321NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3388452119321NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3388453119321NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3388454119321NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3388455119321NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3388456119321NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3388457119321NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3388458119321NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3388459119321NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3388460119321NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3388461119321NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3388462119321NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3388463119321NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3388464119321NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3388465119321NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3388466119321NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3388467119321NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3388468119321NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3388469119321NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3388470119321NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3388471119321NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3388472119321NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3388473119321NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3388474119321NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3388475119321NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3388476119321NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3388477119321NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3388478119321NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3388479119321NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3388480119321NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3388481119321NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3388482119321NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3388483119321NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3388484119321NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3388485119321NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3388486119321NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3388487119321NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3388488119321NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902050000NoneNoneBuildingsHulikeri HWC FF Civil Work SLICE-31866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388489119322NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3388490119322NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3388491119322NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3388492119322NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3388493119322NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3388494119322NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3388495119322NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3388496119322NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3388497119322NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3388498119322NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3388499119322NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3388500119322NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3388501119322NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3388502119322NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3388503119322NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3388504119322NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3388505119322NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3388506119322NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3388507119322NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3388508119322NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3388509119322NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3388510119322NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3388511119322NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3388512119322NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3388513119322NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3388514119322NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3388515119322NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3388516119322NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3388517119322NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3388518119322NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3388519119322NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3388520119322NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3388521119322NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3388522119322NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3388523119322NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3388524119322NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3388525119322NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3388526119322NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3388527119322NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3388528119322NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3388529119322NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3388530119322NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902050000NoneNoneBuildingsHulikeri HWC WS Work SLICE-3254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388531119323NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3388532119323NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3388533119323NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3388534119323NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3388535119323NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3388536119323NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3388537119323NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3388538119323NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3388539119323NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3388540119323NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3388541119323NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3388542119323NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3388543119323NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3388544119323NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3388545119323NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3388546119323NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3388547119323NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3388548119323NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3388549119323NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3388550119323NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3388551119323NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3388552119323NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3388553119323NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3388554119323NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3388555119323NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3388556119323NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3388557119323NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3388558119323NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3388559119323NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3388560119323NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3388561119323NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3388562119323NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3388563119323NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3388564119323NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902050000NoneNoneBuildingsHulikeri HWC Electrical Work SLICE-3375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388565119324NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3388566119324NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3388567119324NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3388568119324NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3388569119324NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3388570119324NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388571119324NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3388572119324NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3388573119324NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3388574119324NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3388575119324NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3388576119324NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3388577119324NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3388578119324NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3388579119324NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3388580119324NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3388581119324NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3388582119324NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3388583119324NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388584119324NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3388585119324NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3388586119324NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3388587119324NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3388588119324NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3388589119324NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3388590119324NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3388591119324NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3388592119324NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3388593119324NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3388594119324NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3388595119324NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3388596119324NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3388597119324NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3388598119324NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3388599119324NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3388600119324NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3388601119324NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3388602119324NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3388603119324NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3388604119324NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3388605119324NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3388606119324NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3388607119324NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3388608119324NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3388609119324NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3388610119324NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3388611119324NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3388612119324NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3388613119324NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3388614119324NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3388615119324NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3388616119324None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388617119324NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3388618119324NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3388619119324NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3388620119324NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3388621119324NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388622119324NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3388623119324NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3388624119324NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3388625119324NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3388626119324NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3388627119324NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3388628119324NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3388629119324NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3388630119324NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3388631119324NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3388632119324NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3388633119324NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3388634119324NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
17194902050000NoneNoneBuildingsNeeralakatti HWC GF Civil Work SLICE-43603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388635119325NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3388636119325NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3388637119325NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3388638119325NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3388639119325NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3388640119325NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3388641119325NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3388642119325NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3388643119325NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3388644119325NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3388645119325NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3388646119325NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3388647119325NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3388648119325NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3388649119325NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3388650119325NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3388651119325NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3388652119325NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3388653119325NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3388654119325NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3388655119325NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3388656119325NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3388657119325NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3388658119325NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3388659119325NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3388660119325NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3388661119325NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3388662119325NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3388663119325NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3388664119325NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3388665119325NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3388666119325NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3388667119325NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3388668119325NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3388669119325NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3388670119325NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3388671119325NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3388672119325NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3388673119325NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3388674119325NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3388675119325NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3388676119325NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3388677119325NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3388678119325NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3388679119325NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3388680119325NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3388681119325NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3388682119325NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3388683119325NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3388684119325NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3388685119325NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3388686119325NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3388687119325NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3388688119325NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3388689119325NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902060000NoneNoneBuildingsNeeralakatti HWC FF Civil Work SLICE-41866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388690119326NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3388691119326NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3388692119326NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3388693119326NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3388694119326NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3388695119326NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3388696119326NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3388697119326NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3388698119326NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3388699119326NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3388700119326NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3388701119326NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3388702119326NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3388703119326NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3388704119326NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3388705119326NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3388706119326NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3388707119326NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3388708119326NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3388709119326NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3388710119326NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3388711119326NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3388712119326NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3388713119326NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3388714119326NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3388715119326NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3388716119326NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3388717119326NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3388718119326NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3388719119326NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3388720119326NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3388721119326NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3388722119326NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3388723119326NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3388724119326NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3388725119326NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3388726119326NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3388727119326NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3388728119326NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3388729119326NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3388730119326NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3388731119326NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902060000NoneNoneBuildingsNeeralakatti HWC WS Work SLICE-4254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388732119327NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3388733119327NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3388734119327NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3388735119327NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3388736119327NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3388737119327NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3388738119327NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3388739119327NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3388740119327NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3388741119327NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3388742119327NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3388743119327NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3388744119327NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3388745119327NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3388746119327NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3388747119327NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3388748119327NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3388749119327NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3388750119327NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3388751119327NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3388752119327NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3388753119327NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3388754119327NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3388755119327NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3388756119327NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3388757119327NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3388758119327NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3388759119327NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3388760119327NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3388761119327NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3388762119327NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3388763119327NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3388764119327NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3388765119327NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902060000NoneNoneBuildingsNeeralakatti HWC Electrical Work SLICE-4375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388766119328NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3388767119328NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3388768119328NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3388769119328NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3388770119328NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3388771119328NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388772119328NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3388773119328NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3388774119328NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3388775119328NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3388776119328NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3388777119328NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3388778119328NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3388779119328NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3388780119328NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3388781119328NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3388782119328NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3388783119328NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3388784119328NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388785119328NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3388786119328NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3388787119328NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3388788119328NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3388789119328NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3388790119328NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3388791119328NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3388792119328NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3388793119328NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3388794119328NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3388795119328NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3388796119328NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3388797119328NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3388798119328NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3388799119328NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3388800119328NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3388801119328NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3388802119328NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3388803119328NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3388804119328NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3388805119328NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3388806119328NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3388807119328NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3388808119328NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3388809119328NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3388810119328NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3388811119328NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3388812119328NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3388813119328NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3388814119328NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3388815119328NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3388816119328NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3388817119328None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388818119328NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3388819119328NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3388820119328NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3388821119328NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3388822119328NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3388823119328NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3388824119328NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3388825119328NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3388826119328NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3388827119328NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3388828119328NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3388829119328NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3388830119328NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3388831119328NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3388832119328NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3388833119328NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3388834119328NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3388835119328NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
17194902060000NoneNoneBuildingsMummigatti HWC GF Civil Work SLICE-53603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388836119329NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3388837119329NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3388838119329NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3388839119329NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3388840119329NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3388841119329NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3388842119329NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3388843119329NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3388844119329NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3388845119329NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3388846119329NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3388847119329NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3388848119329NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3388849119329NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3388850119329NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3388851119329NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3388852119329NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3388853119329NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3388854119329NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3388855119329NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3388856119329NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3388857119329NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3388858119329NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3388859119329NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3388860119329NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3388861119329NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3388862119329NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3388863119329NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3388864119329NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3388865119329NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3388866119329NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3388867119329NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3388868119329NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3388869119329NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3388870119329NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3388871119329NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3388872119329NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3388873119329NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3388874119329NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3388875119329NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3388876119329NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3388877119329NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3388878119329NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3388879119329NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3388880119329NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3388881119329NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3388882119329NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3388883119329NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3388884119329NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3388885119329NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3388886119329NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3388887119329NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3388888119329NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3388889119329NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3388890119329NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902060000NoneNoneBuildingsMummigatti HWC FF Civil Work SLICE-51866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388891119330NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3388892119330NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3388893119330NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3388894119330NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3388895119330NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3388896119330NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3388897119330NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3388898119330NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3388899119330NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3388900119330NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3388901119330NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3388902119330NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3388903119330NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3388904119330NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3388905119330NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3388906119330NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3388907119330NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3388908119330NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3388909119330NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3388910119330NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3388911119330NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3388912119330NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3388913119330NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3388914119330NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3388915119330NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3388916119330NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3388917119330NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3388918119330NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3388919119330NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3388920119330NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3388921119330NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3388922119330NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3388923119330NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3388924119330NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3388925119330NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3388926119330NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3388927119330NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3388928119330NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3388929119330NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3388930119330NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3388931119330NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3388932119330NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902060000NoneNoneBuildingsMummigatti HWC WS Work SLICE-5254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388933119331NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3388934119331NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3388935119331NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3388936119331NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3388937119331NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3388938119331NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3388939119331NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3388940119331NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3388941119331NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3388942119331NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3388943119331NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3388944119331NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3388945119331NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3388946119331NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3388947119331NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3388948119331NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3388949119331NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3388950119331NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3388951119331NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3388952119331NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3388953119331NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3388954119331NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3388955119331NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3388956119331NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3388957119331NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3388958119331NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3388959119331NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3388960119331NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3388961119331NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3388962119331NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3388963119331NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3388964119331NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3388965119331NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3388966119331NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902060000NoneNoneBuildingsMummigatti HWC Electrical Work SLICE-5375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3388967119332NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3388968119332NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3388969119332NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3388970119332NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3388971119332NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3388972119332NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388973119332NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3388974119332NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3388975119332NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3388976119332NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3388977119332NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3388978119332NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3388979119332NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3388980119332NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3388981119332NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3388982119332NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3388983119332NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3388984119332NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3388985119332NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3388986119332NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3388987119332NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3388988119332NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3388989119332NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3388990119332NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3388991119332NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3388992119332NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3388993119332NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3388994119332NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3388995119332NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3388996119332NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3388997119332NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3388998119332NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3388999119332NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3389000119332NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3389001119332NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3389002119332NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3389003119332NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3389004119332NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3389005119332NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3389006119332NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3389007119332NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3389008119332NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3389009119332NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3389010119332NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3389011119332NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3389012119332NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3389013119332NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3389014119332NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3389015119332NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3389016119332NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3389017119332NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3389018119332None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3389019119332NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3389020119332NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3389021119332NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3389022119332NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3389023119332NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3389024119332NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3389025119332NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3389026119332NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3389027119332NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3389028119332NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3389029119332NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3389030119332NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3389031119332NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3389032119332NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3389033119332NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3389034119332NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3389035119332NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3389036119332NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
17194902060000NoneNoneBuildingsBelavantar HWC GF Civil Work SLICE-63603057.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3389037119333NoneItem 1.12Ground Floor Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depthnot exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting and stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery and other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeha112.1112.172.58FalseNoneNoneFalseNoneFalse8136.2180
3389038119333NoneItem 1.14.1Ground Floor Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36169.61FalseNoneNoneFalseNoneFalse20414.25960
3389039119333NoneItem 5.4Ground Floor Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 16 1 cement 6 coarse sand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7539.027539.023.8FalseNoneNoneFalseNoneFalse28648.2760
3389040119333NoneItem 2.1.3Ground Floor PCC Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0220.5FalseNoneNoneFalseNoneFalse144873.910
3389041119333NoneItem 2.2.3Ground Floor FOOTINGS Providing and laying in position Cement Concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead and lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 8% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8074.598074.5919.4FalseNoneNoneFalseNoneFalse156647.0460
3389042119333NoneItem 2.5.2Ground Floor COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.066.5FalseNoneNoneFalseNoneFalse89225.890
3389043119333NoneItem 2.5.2Ground Floor PLINTH BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.05FalseNoneNoneFalseNoneFalse73278.26550
3389044119333NoneItem 2.5.2Ground Floor Curtain Wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13727.0613727.068.5FalseNoneNoneFalseNoneFalse116680.010
3389045119333NoneItem 2.5.2Ground Floor LINTEL and ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12919.5812919.589.3FalseNoneNoneFalseNoneFalse120152.0940
3389046119333NoneItem 2.5.2Ground Floor RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.1113.5FalseNoneNoneFalseNoneFalse163513.4850
3389047119333NoneItem 2.5.2Ground Floor RCC STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12112.1112112.116.0FalseNoneNoneFalseNoneFalse72672.660
3389048119333NoneItem 2.5.1Ground Floor RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.6FalseNoneNoneFalseNoneFalse6806.3580
3389049119333NoneItem 2.5.1Ground Floor Septic Tank and Sump Tank Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3389050119333NoneItem 1.9Ground Floor Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88110.4FalseNoneNoneFalseNoneFalse34652.3520
3389051119333NoneItem 1.8Ground Floor Construction of Embankment by excavating the available approved GravelorMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum559.32559.3254.5FalseNoneNoneFalseNoneFalse30482.940
3389052119333NoneItem 2.1.4Ground Floor Cill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortrap orbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using platevibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.21FalseNoneNoneFalseNoneFalse23548.75260
3389053119333NoneItem 2.11aGround Floor Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget105559.26105559.267.954FalseNoneNoneFalseNoneFalse839618.354040
3389054119333NoneItem 6.32Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1545.81545.8202.0FalseNoneNoneFalseNoneFalse312251.60
3389055119333NoneItem 6.34Ground Floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part to I to 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour,scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1302.721302.7239.5FalseNoneNoneFalseNoneFalse51457.440
3389056119333NoneItem 12.13.1Ground Floor Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.5FalseNoneNoneFalseNoneFalse58300.850
3389057119333NoneItem 12.51Ground Floor Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3389058119333NoneItem 10.6Ground Floor Providing and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion type Fastener with threaded dia 6 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57.8257.827.0FalseNoneNoneFalseNoneFalse404.740
3389059119333NoneItem 12.75.4Ground Floor Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach165.2165.221.0FalseNoneNoneFalseNoneFalse3469.20
3389060119333NoneItem 12.57.6Ground Floor Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 parttoI 1991. from manufacturer complete as per spcification.todoto 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3919.963919.9615.0FalseNoneNoneFalseNoneFalse58799.40
3389061119333NoneItem 12.86Ground Floor Providing and fixing of 2totrack x 2topanel sliding windows made out of multichambered UPVC Matching to RALto9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets togrey colour having isolated drainage and reinforced with Galvanized Iron profile throughtoout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass,tandardhardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8 to 0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6360.26360.214.0FalseNoneNoneFalseNoneFalse89042.80
3389062119333NoneItem 11.34AGround Floor Providing and fixing M.Sgrills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24295.0FalseNoneNoneFalseNoneFalse58480.80
3389063119333NoneItem 12.54Ground Floor SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2410.0FalseNoneNoneFalseNoneFalse3752.40
3389064119333NoneItem 12.53Ground Floor Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineertointocharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1873.841873.843.15FalseNoneNoneFalseNoneFalse5902.5960
3389065119333NoneItem 8.10Ground Floor Providing 6 mm cement plaster with cement mortar 13 1 cement 3 fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm248.98248.9886.0FalseNoneNoneFalseNoneFalse21412.280
3389066119333NoneItem 8.1.1Ground Floor Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.9490.0FalseNoneNoneFalseNoneFalse147441.00
3389067119333NoneItem 8.1.2Ground Floor Providing 12 mm cement plaster with cement mortar 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3389068119333NoneItem 8.51Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0517.0FalseNoneNoneFalseNoneFalse61006.00
3389069119333NoneItem 8.8Ground Floor Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 15 1 cement 5 coarse sand finishedwith a top layer 6 mm thick cement plaster with cement mortar 16 1cement 6fine sand to brick masonry including rounding off cornerswherever required smoothrendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78270.0FalseNoneNoneFalseNoneFalse118200.60
3389070119333NoneItem 8.2.1Ground Floor Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.09348.0933.5FalseNoneNoneFalseNoneFalse11661.0150
3389071119333NoneItem 15.7Ground Floor Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selftoseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrotostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for Mto20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm725.69725.696.15FalseNoneNoneFalseNoneFalse4462.99350
3389072119333NoneItem 9.21.2Ground Floor Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1460.841460.8478.0FalseNoneNoneFalseNoneFalse113945.520
3389073119333NoneItem 9.23Ground Floor Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineertointoCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8826.0FalseNoneNoneFalseNoneFalse75656.880
3389074119333NoneItem 9.11Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.026.15FalseNoneNoneFalseNoneFalse6451.4730
3389075119333NoneItem 9.38Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5637.0FalseNoneNoneFalseNoneFalse60774.720
3389076119333NoneItem 9.36Ground Floor Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.06.5FalseNoneNoneFalseNoneFalse12655.50
3389077119333NoneItem 11.26.1Ground Floor Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineertointoCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm162.84162.84245.0FalseNoneNoneFalseNoneFalse39895.80
3389078119333NoneItem 8.39Ground Floor Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86517.0FalseNoneNoneFalseNoneFalse77477.620
3389079119333NoneItem 8.30Ground Floor Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltror10 m² over and including priming coat of exterior primer applied at 2.20 kgor10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointo charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32270.0FalseNoneNoneFalseNoneFalse55436.40
3389080119333NoneItem 8.40Ground Floor Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.714.0FalseNoneNoneFalseNoneFalse1899.80
3389081119333NoneItem 8.38Ground Floor Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineertointocharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.1947.1931.3FalseNoneNoneFalseNoneFalse1477.0470
3389082119333NoneItem 12.62Ground Floor Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos279.66279.6624.0FalseNoneNoneFalseNoneFalse6711.840
3389083119333NoneItem 12.58Ground Floor Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos141.6141.612.0FalseNoneNoneFalseNoneFalse1699.20
3389084119333NoneItem 12.8Ground Floor Providing and fixing door latch with necessary screws etc complete.Bright finished brass latch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2924.0FalseNoneNoneFalseNoneFalse8070.960
3389085119333NoneItem 12.63Ground Floor Providing and fixing aluminium tower bolts, ISI marked, anodised anto odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
3389086119333NoneItem 8.16.2Ground Floor Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem44.8444.84309.0FalseNoneNoneFalseNoneFalse13855.560
3389087119333NoneItem Approved Rate HWCGround Floor Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm506.22506.227.1FalseNoneNoneFalseNoneFalse3594.1620
3389088119333NoneItem Approved Rate HWCGround Floor Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem86.1486.1439.4FalseNoneNoneFalseNoneFalse3393.9160
3389089119333NoneItem 1.15.2Sump and Septic Tank Earth work excavation for Foundation by mechanical means for all works anddepth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinaryor soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.76FalseNoneNoneFalseNoneFalse12417.140
3389090119333NoneItem 15.6Sump and Septic Tank Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentapplied at 1.5 kgorm2 for internal side waterproofing in two layers with waiting period of 4to6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3389091119333NoneItem 18.3Sump and Septic Tank Conveying the new CI or RCC machinehole frame and cover of 2 CMTS from divisional stores to the workspot and fixing the same in cement concrete and removing the old frame and cover and conveying back the old ones to stores. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
17194902060000NoneNoneBuildingsBelavantar HWC FF Civil Work SLICE-61866858.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3389092119334NoneItem 2.5.2FF COLUMNS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 70% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13864.3313864.333.4FalseNoneNoneFalseNoneFalse47138.7220
3389093119334NoneItem 2.5.2FF RCC BEAMS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.784.55FalseNoneNoneFalseNoneFalse59371.9490
3389094119334NoneItem 2.5.2FF RCC SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 50% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12233.2312233.2312.0FalseNoneNoneFalseNoneFalse146798.760
3389095119334NoneItem 2.5.2FF LINTELS Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 60% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13048.7813048.782.5FalseNoneNoneFalseNoneFalse32621.950
3389096119334NoneItem 2.5.1FF RCC For Chajja Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works and super structure worksof bridges upto 3.50 m height. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead and lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 45% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3711457.370.4FalseNoneNoneFalseNoneFalse4582.9480
3389097119334NoneItem 2.1.4FFCill concrete Providing and laying in position Cement Concrete for levelling course forall works in foundation. The graniteortraporbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead and lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 136 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.422.1FalseNoneNoneFalseNoneFalse15559.7820
3389098119334NoneItem 2.11aFF Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget106614.85106614.852.95FalseNoneNoneFalseNoneFalse314513.80750
3389099119334NoneItem Approved Rate HWCFF Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem87.087.029.0FalseNoneNoneFalseNoneFalse2523.00
3389100119334NoneItem 6.32FFProviding and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constr ucted with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1561.261561.26197.0FalseNoneNoneFalseNoneFalse307568.220
3389101119334NoneItem 6.34FF Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kgorm3and minimum compressive strength of 4.00 Normm2 conforming to IS2185 Part I 2005 and constructed with CM 14 as per IS 25722005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1315.751315.7543.5FalseNoneNoneFalseNoneFalse57235.1250
3389102119334NoneItem 12.13.1FF Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.3FalseNoneNoneFalseNoneFalse35330.3130
3389103119334NoneItem 12.51FF Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 136 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3389104119334NoneItem 10.6FFProviding and fixing expansion hold fasteners on C.C. orR.C.C.orBrick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach58.3958.394.0FalseNoneNoneFalseNoneFalse233.560
3389105119334NoneItem 12.75.4FF Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm ordinary type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.85166.8518.0FalseNoneNoneFalseNoneFalse3003.30
3389106119334NoneItem 12.57.6FF Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side commercial. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3959.163959.168.0FalseNoneNoneFalseNoneFalse31673.280
3389107119334NoneItem 12.86FF Providing and fixing of 2track x 2panel sliding windows made out of multichambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6423.86423.812.42FalseNoneNoneFalseNoneFalse79783.5960
3389108119334NoneItem 11.34AFF Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22333.0FalseNoneNoneFalseNoneFalse66673.260
3389109119334NoneItem 12.54FF SOLID PVC Door Frame Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and joined 2 No.s of 150mm long brackets of 15x15mm M.S. Square tube, the entire door frame to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65or80mm size complete as per manufacturers specification and direction of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.9910.0FalseNoneNoneFalseNoneFalse3789.90
3389110119334NoneItem 12.53FF Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1892.571892.573.2FalseNoneNoneFalseNoneFalse6056.2240
3389111119334NoneItem 8.10FF Providing 6 mm cement plaster with cement mortar 13 1 cement 3fine sand on concrete surface or ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm251.47251.4778.0FalseNoneNoneFalseNoneFalse19614.660
3389112119334NoneItem 8.1.1FF Providing 12 mm cement plaster with cement mortar 14 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. Inside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm303.91303.91234.5FalseNoneNoneFalseNoneFalse71266.8950
3389113119334NoneItem 8.51FF Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18311.0FalseNoneNoneFalseNoneFalse37064.980
3389114119334NoneItem 8.80FF Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16248.0FalseNoneNoneFalseNoneFalse109655.680
3389115119334NoneItem 8.2.1FF Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 14 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5825.704FalseNoneNoneFalseNoneFalse9037.012320
3389116119334NoneItem 8.16.2FF Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gorm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem45.2845.28120.59FalseNoneNoneFalseNoneFalse5460.31520
3389117119334NoneItem 7.18FF Providing and laying cinder concrete in cement 115 1 cement 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2403.862403.861.52FalseNoneNoneFalseNoneFalse3653.86720
3389118119334NoneItem 15.7FF Integral Crystalline Water Proofing Admixture Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetrationagainst control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitiouscontent in concrete. ie., integral crystaline waterproofing admix at 0.5kgorbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm732.96732.9611.16FalseNoneNoneFalseNoneFalse8179.83360
3389119119334NoneItem 9.21.2FF Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1475.451475.4557.0FalseNoneNoneFalseNoneFalse84100.650
3389120119334NoneItem 9.11FF Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 14 1 Cement 4 Coarse sand, jointing with grey cement slurry at 3.3 kgor m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.516.2FalseNoneNoneFalseNoneFalse6568.9620
3389121119334NoneItem 9.38FF Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 13 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9825.704FalseNoneNoneFalseNoneFalse42642.421920
3389122119334NoneItem 9.36FF Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 16, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.472.69FalseNoneNoneFalseNoneFalse5289.80430
3389123119334NoneItem 9.23FF Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 14 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2938.972938.973.25FalseNoneNoneFalseNoneFalse9551.65250
3389124119334NoneItem 8.39FFWall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36234.0FalseNoneNoneFalseNoneFalse35418.240
3389125119334NoneItem 8.30FF Finishing walls with Acrylic Smooth exterior paint of required shade Newwork Two coat applied at 1.67Lor10 m² over and including priming coat ofexterior primer applied at 2.20 kgor10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineerincharge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37248.0FalseNoneNoneFalseNoneFalse51427.760
3389126119334NoneItem 8.40FF Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0512.5FalseNoneNoneFalseNoneFalse1713.1250
3389127119334NoneItem 8.38FF Painting with oil type wood preservative of approved brand and anufacture New work two coats to give an even shade including preparingthe surface after thorougly cleaning oil, grease, dirt and foreign matter,sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm47.6747.6719.2FalseNoneNoneFalseNoneFalse915.2640
3389128119334NoneItem 12.62FF Providing and fixing chromium plated brass handles of 100or125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
3389129119334NoneItem 12.58FF Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.016.0FalseNoneNoneFalseNoneFalse858.060
3389130119334NoneItem 12.8FF Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo339.66339.6612.0FalseNoneNoneFalseNoneFalse4075.920
3389131119334NoneItem 12.63FF Providing and fixing aluminium tower bolts, ISI marked, anodised an odic coating not less than grade AC 10 as per IS 1868 transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9312.0FalseNoneNoneFalseNoneFalse1859.160
3389132119334NoneItem Approved Rate HWCFF Providing RCC loft atta 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form of work, centring, curing, etc., complete exclusive of cost of steel and fabrication charges. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm511.28511.2814.25FalseNoneNoneFalseNoneFalse7285.740
3389133119334NoneItem 15.1FF Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceorChajjasorSunken portion of WCBathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgorm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gorm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.7132.0FalseNoneNoneFalseNoneFalse128528.40
17194902060000NoneNoneBuildingsBelavantar HWC WS Work SLICE-6254256.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3389134119335NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5708.845708.841.0FalseNoneNoneFalseNoneFalse5708.840
3389135119335NoneItem 14.1.1Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3389136119335NoneItem 14.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3381.883381.882.0FalseNoneNoneFalseNoneFalse6763.760
3389137119335NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.85.0FalseNoneNoneFalseNoneFalse4779.00
3389138119335NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3389139119335NoneItem 14.10.1.2Providing and fixing Stainless Steel A ISI 304 18or8 kitchen sink as per IS13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3389140119335NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required Size600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5996.755996.751.0FalseNoneNoneFalseNoneFalse5996.750
3389141119335NoneItem 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.465.0FalseNoneNoneFalseNoneFalse277.30
3389142119335NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P.or H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.921.0FalseNoneNoneFalseNoneFalse1585.920
3389143119335NoneItem 13.59Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.595.0FalseNoneNoneFalseNoneFalse1297.950
3389144119335NoneItem 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3389145119335NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3389146119335NoneItem 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3389147119335NoneItem 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3389148119335NoneItem T090 SR 202122Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make includingtrench excavation and refilling etc. for EXTERNAL WORKS with 50mm nominal bore pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164.02164.0215.0FalseNoneNoneFalseNoneFalse2460.30
3389149119335NoneItem 166C.P. Brass stop cock concealed 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3389150119335NoneItem 163Brass bibcock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3389151119335NoneItem Approved Rate HWCAir Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo118.0118.02.0FalseNoneNoneFalseNoneFalse236.00
3389152119335NoneItem Approved Rate HWCSupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.3 no. working and 1no. Standby Sump To OHT DOMESTIC 2HP at 35m head SUMP TO OHTDOMESTIC WATER PUMPS For water sump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3389153119335NoneItem 10.1.5Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 75 mm dia, 6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.59259.5925.0FalseNoneNoneFalseNoneFalse6489.750
3389154119335NoneItem 10.1.6Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 90 mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9250.0FalseNoneNoneFalseNoneFalse17346.00
3389155119335NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9860.0FalseNoneNoneFalseNoneFalse29098.80
3389156119335NoneItem 10.1.8Supplying PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 140mm dia,6 kgorsqcm and class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1220.0FalseNoneNoneFalseNoneFalse13782.40
3389157119335NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6218.0FalseNoneNoneFalseNoneFalse6563.160
3389158119335NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2232.0FalseNoneNoneFalseNoneFalse14311.040
3389159119335NoneItem 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8830.0FalseNoneNoneFalseNoneFalse5876.40
3389160119335NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem256.06256.0645.0FalseNoneNoneFalseNoneFalse11522.70
3389161119335NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8615.0FalseNoneNoneFalseNoneFalse8442.90
3389162119335NoneItem 13.48Providing and fixing on wallafce unplasticised rigid PVC rain water pipes confirming to IS 13592 Type A, Including jointing with seal ring confirming to IS 5382 Leaving 10mm gap thermal expansion, i Single socketed pipes 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3845.0FalseNoneNoneFalseNoneFalse15452.10
3389163119335NoneItem Approved Rate HWCDrilling holes of 2.50 cms dia rooforchajjaorstone. in slabs upto 10 cms thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.26185.2622.0FalseNoneNoneFalseNoneFalse4075.720
3389164119335NoneItem 13.34Providing and placing on terrace, at all floor levels polythylene water storage tanks as per IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet,outlet and over flow pipes, but without fitting and basesupport fot tank ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.621000.0FalseNoneNoneFalseNoneFalse10620.00
3389165119335NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75in cement mortar 16, bed concrete 150mm thick with 136, plastering 12 mm thick with cement mortar 14, CC 124 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5653.385653.385.0FalseNoneNoneFalseNoneFalse28266.90
3389166119335NoneItem 1.5.1Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including costof labour, tools, usage and other appurtenances required to complete the work.In ordinaryorsoft rock without blasting upto 1.5 m depth Drain Pipe To Public Drain ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum352.82352.825.94FalseNoneNoneFalseNoneFalse2095.75080
3389167119335NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 mand lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.885.94FalseNoneNoneFalseNoneFalse1864.44720
17194902060000NoneNoneBuildingsBelavantar HWC Electrical Work SLICE-6375711.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3389168119336NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3389169119336NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3389170119336NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS694 and latest amendments without control switch shall be fixed on the existing plastic sheetorgang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3389171119336NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3389172119336NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3389173119336NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 45Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3389174119336NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.59259.5910.0FalseNoneNoneFalseNoneFalse2595.90
3389175119336NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.97307.976.0FalseNoneNoneFalseNoneFalse1847.820
3389176119336NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1012Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3389177119336NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3389178119336NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3389179119336NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3389180119336NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3389181119336NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3389182119336NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1012Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3389183119336NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3389184119336NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3389185119336NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3389186119336NoneItem 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3389187119336NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3389188119336NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3389189119336NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3389190119336NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3389191119336NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3389192119336NoneItem 1.13Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3389193119336NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3389194119336NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3389195119336NoneItem 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3389196119336NoneItem 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc, by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3389197119336NoneItem 2.3.2WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3389198119336NoneItem 2.3.3WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3389199119336NoneItem 2.3.4WIRING FOR LightingorPower Circuits Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latestamendments.4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3389200119336NoneItem 5.19.9MCB DB Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3389201119336NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3389202119336NoneItem 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB240or450V upto 300mA sensitivity on existing woodor panel board. Board 1625 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3389203119336NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input 220240V at 50or60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.19814.1915.0FalseNoneNoneFalseNoneFalse12212.850
3389204119336NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3389205119336NoneItem 11.11.7Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3389206119336NoneItem 12.27LED Street light.Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3389207119336NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3389208119336NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3389209119336NoneItem 12.46Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3389210119336NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3389211119336NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3389212119336NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3389213119336NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3389214119336NoneItem BSR 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3389215119336NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3389216119336NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1KV class metal only 1920 SR 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3389217119336NoneItem 6.17.5Supplying tinned copper lugs and crimping andwiring to terminal point for wire of the following sizes 1920SR10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3389218119336NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directedIn ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3389219119336None5.42.1Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3389220119336NoneItem 5.40.3Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.095245.091.5FalseNoneNoneFalseNoneFalse7867.6350
3389221119336NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3389222119336NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3389223119336NoneItem 7.1.2Supplying litres capacity verticalorhorizontal type wall mounting Electrical water heater with 22 SWG copperorSS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40or0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.6910342.691.0FalseNoneNoneFalseNoneFalse10342.690
3389224119336NoneItem 5.42.1Meetering Panel Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5930000.0FalseNoneNoneFalseNoneFalse17700.00
3389225119336NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3389226119336NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3389227119336NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3389228119336NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 5063Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
3389229119336NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3389230119336NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3389231119336NoneItem 5.12.1Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3389232119336NoneItem 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3389233119336NoneItem 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.79188.791.0FalseNoneNoneFalseNoneFalse188.790
3389234119336NoneItem 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3389235119336NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C 48or6.36 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.69607.692.0FalseNoneNoneFalseNoneFalse1215.380
3389236119336NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3389237119336NoneItem 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.391628.392.0FalseNoneNoneFalseNoneFalse3256.780
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194902080000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194902080000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194902080001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17194902080000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194902080000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194902800000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17194902970000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17194903220000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194903370000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17194903510000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17194903690000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17194903860000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17194904060000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17194904210000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17194904370000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17194904520000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17194904730000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17194905110000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17194905270000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17194905560000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17194906160000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17194906380000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17194906700000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22 , 2022-23 & 2023-24.None
17194906850000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.183.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.11.50 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.8.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneKPWD Class-II & above Registration Certificate.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation -1300.00 Cum,2)RCC and PCC -628.00 Cum 3)Steel Reinforcement for RCC work- 52.00 Tonnes 4)Cement concrete Block Masonry/Solid Block Masonry/- 2314.00 Sqm 5)Flooring/Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing) -1200.00 Sqm, 6)Plastering-7000.00 Sqm,7)Painting -6100.00 Sqm (8)MS grill- 3000.00 Kg, 9)WPC - 1000.00 sqm, Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1 Min 10 cft capacity Concrete Mixer-3 Nos. 2. Centering sheets-400 sqmtr 3.Tipper-1 Nos 4.Water tanker-1 No 5.Bar, Bending and cutting machine 1 No..Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax invoice & receipt
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitments and on-going works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No,Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -2 Two No 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working inpermanent role of the organization for at least two years-1 One No. Degree certificate and Experience Certificate to be furnished.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.731.98 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Turnover Certificate Profit & Loss Certificate issued and duly certified by the charted accountant
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.110.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
PWD Class-II & above Registration certificate issued by Chief Engineer PWDTrueTechnical Bid
Workdone certificate issued by the Officer not below the rank of Executive EngineerTrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their name.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.rtificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719492705000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023