createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719487647416
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2490.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-07-2024 16:00:00
tenderQueryClose03-07-2024 12:30:30
technicalBidOpen09-07-2024 16:10:00
publishedDate27-06-2024 18:14:46
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPraveen B A Technical Assistanat
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1719487647444
version13
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT498
titleCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT (1)TLH K.R NAGARA and (2)TLH T.NARASIPURA IN MYSURU DISTRICT.
descriptionCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT (1)TLH K.R NAGARA and (2)TLH T.NARASIPURA IN MYSURU DISTRICT.
categoryWORKS
categoryTextWorks
ecv9937156.96
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount10000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/MYS/BPHU/KRNagarTNPura
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194876470000NoneNoneBuildings1 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH K.R NAGARA IN MYSURU DISTRICT. (Civil Works) (Slice-1)4167301.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385873119245NoneI-2.5A P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle. ---- etc., complete with all leadSqm477.65477.652.17FalseNoneNoneFalseNoneFalse1036.50050
3385874119245NoneI-1.12 P-8 V-1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.4665.25FalseNoneNoneFalseNoneFalse7533.7650
3385875119245NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.9799.14FalseNoneNoneFalseNoneFalse12290.38580
3385876119245NoneI-1.15.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. ---- etc., complete with all leadCum441.19441.1910.25FalseNoneNoneFalseNoneFalse4522.19750
3385877119245NoneI-1.1B P-5 V-3Loading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 10 m3 ) ---- etc., complete with all leadCum144.63144.6360.25FalseNoneNoneFalseNoneFalse8713.95750
3385878119245NoneI-1.9 P-34 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.399.91FalseNoneNoneFalseNoneFalse32300.9030
3385879119245NoneI-1.8 P-33 V-1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials,usage & all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.164.91FalseNoneNoneFalseNoneFalse37394.6510
3385880119245NoneI-2.1.3 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all leadCum7279.037279.0329.86FalseNoneNoneFalseNoneFalse217351.83580
3385881119245NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all leadCum8316.848316.8418.12FalseNoneNoneFalseNoneFalse150701.14080
3385882119245NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all leadCum8316.848316.842.59FalseNoneNoneFalseNoneFalse21540.61560
3385883119245NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS ---- etc., complete with all leadCum13698.7713698.779.0FalseNoneNoneFalseNoneFalse123288.930
3385884119245NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, RCC SLAB ---- etc., complete with all leadCum12087.1512087.1537.61FalseNoneNoneFalseNoneFalse454597.71150
3385885119245NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS, LINTELS ---- etc., complete with all leadCum12892.9612892.9613.17FalseNoneNoneFalseNoneFalse169800.28320
3385886119245NoneI-2.1.4 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all leadCum7556.147556.143.35FalseNoneNoneFalseNoneFalse25313.0690
3385887119245NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ Epoxy ---- etc., complete with all leadNo.247.94247.9410.0FalseNoneNoneFalseNoneFalse2479.40
3385888119245NoneI-8.16a P-55 V-2Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- etc., complete with all leadSqm1504.671504.674.5FalseNoneNoneFalseNoneFalse6771.0150
3385889119245NoneI-2.11 P-84 V-2Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings ---- etc., complete with all leadTonne108726.04108726.045.95FalseNoneNoneFalseNoneFalse646919.9380
3385890119245NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS. (P. No. 14/ I.No. 4.21 of PWD 2018-19) ---- etc., complete with all leadRmtr40.1140.1154.0FalseNoneNoneFalseNoneFalse2165.940
3385891119245NoneI-5.4 P-9 V-2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.1920.82FalseNoneNoneFalseNoneFalse161671.25580
3385892119245NoneI-6.32 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17164.48FalseNoneNoneFalseNoneFalse261880.12160
3385893119245NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.867.33FalseNoneNoneFalseNoneFalse90343.3940
3385894119245NoneI-12.13.1 P-100 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.750.99FalseNoneNoneFalseNoneFalse118898.75250
3385895119245NoneI-12.51 P-104 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.8512.0FalseNoneNoneFalseNoneFalse14818.20
3385896119245NoneI-12.60 P-105 V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.612.0FalseNoneNoneFalseNoneFalse15343.20
3385897119245NoneI-12.61 P-105 V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos1203.251203.2512.0FalseNoneNoneFalseNoneFalse14439.00
3385898119245NoneI-12.62 P-105 V-2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.0524.0FalseNoneNoneFalseNoneFalse6913.20
3385899119245NoneI-12.63 P-107 V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos158.0158.024.0FalseNoneNoneFalseNoneFalse3792.00
3385900119245NoneI-12.64 P-107 V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.8512.0FalseNoneNoneFalseNoneFalse802.20
3385901119245NoneI-12.75.1 P-107 V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2424.0FalseNoneNoneFalseNoneFalse8021.760
3385902119245NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9272.0FalseNoneNoneFalseNoneFalse5250.240
3385903119245NoneI-15.37 P-117 S.R 2018-19KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment) ---- etc., complete with all leadRmtr34.0334.0377.6FalseNoneNoneFalseNoneFalse2640.7280
3385904119245NoneI-12.57.6 P-105 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.564037.5628.56FalseNoneNoneFalseNoneFalse115312.71360
3385905119245NoneI-12.90 P-110 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- etc., complete with all leadSqm8184.58184.527.0FalseNoneNoneFalseNoneFalse220981.50
3385906119245NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- etc., complete with all leadSqm6950.876950.871.44FalseNoneNoneFalseNoneFalse10009.25280
3385907119245NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19597.24FalseNoneNoneFalseNoneFalse121950.43560
3385908119245NoneI-12.96 P-112 V-2Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadm781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
3385909119245NoneI-12.97.1 P-112 V-2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness. ---- etc., complete with all leadSqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
3385910119245NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.9612.0FalseNoneNoneFalseNoneFalse16247.520
3385911119245NoneI-11.25.2 P-84 V-2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge ---- etc., complete with all leadKgs165.29165.29241.92FalseNoneNoneFalseNoneFalse39986.95680
3385912119245NoneI-11.35.1.1 P-86 V-2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadKg549.36549.3654.0FalseNoneNoneFalseNoneFalse29665.440
3385913119245NoneI-11.37.1 P-89 V-2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm1200.821200.827.2FalseNoneNoneFalseNoneFalse8645.9040
3385914119245NoneI-8.10 P-41 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm320.56320.56142.71FalseNoneNoneFalseNoneFalse45747.11760
3385915119245NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm530.22530.22317.43FalseNoneNoneFalseNoneFalse168307.73460
3385916119245NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.54294.25FalseNoneNoneFalseNoneFalse35763.1450
3385917119245NoneI-8.8 P-42 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm563.64563.64222.9FalseNoneNoneFalseNoneFalse125635.3560
3385918119245NoneI-8.16.2 P43 V-2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all leadRmtr46.1946.19375.0FalseNoneNoneFalseNoneFalse17321.250
3385919119245NoneI-10.5.2 P-69 S.R 2018-19Bore Packing : filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulation on the bore. including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm262.53262.5310.0FalseNoneNoneFalseNoneFalse2625.30
3385920119245NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.263.2256.0FalseNoneNoneFalseNoneFalse16179.20
3385921119245NoneI-9.21.2 P-62 V-2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm. ---- etc., complete with all leadSqm1504.671504.67158.92FalseNoneNoneFalseNoneFalse239122.15640
3385922119245NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm358.54358.5442.84FalseNoneNoneFalseNoneFalse15359.85360
3385923119245NoneI-9.11 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm926.13926.138.34FalseNoneNoneFalseNoneFalse7723.92420
3385924119245NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1260.371260.3742.84FalseNoneNoneFalseNoneFalse53994.25080
3385925119245NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm192.94192.94588.51FalseNoneNoneFalseNoneFalse113547.11940
3385926119245NoneI-8.31 P-46 V-2Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm270.43270.43222.9FalseNoneNoneFalseNoneFalse60278.8470
3385927119245NoneI-8.34.3 P-47 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7728.44FalseNoneNoneFalseNoneFalse1728.29880
3385928119245NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7728.44FalseNoneNoneFalseNoneFalse3975.05880
3385929119245NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4264.4268.54FalseNoneNoneFalseNoneFalse4415.34680
3385930119245NoneI-8.47 P-49 V-2Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm164.08164.0868.54FalseNoneNoneFalseNoneFalse11246.04320
3385931119245NoneI-10.1.7 P-113 V-5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm499.53499.5324.0FalseNoneNoneFalseNoneFalse11988.720
17194876470000NoneNoneBuildings1 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH K.R NAGARA IN MYSURU DISTRICT. (Water Supply & Sanitary Works) (Slice-1)321976.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385932119246NoneI-14.28.2.2 P-136 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40mm dia pipes ---- etc., complete with all leadEach111.82111.828.0FalseNoneNoneFalseNoneFalse894.560
3385933119246NoneI-16.7.4 P-191 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete with all leadm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3385934119246NoneI-10.1.5 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm267.39267.3940.0FalseNoneNoneFalseNoneFalse10695.60
3385935119246NoneI-10.1.7 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for : PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm499.53499.5335.0FalseNoneNoneFalseNoneFalse17483.550
3385936119246NoneI-13.47 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3385937119246NoneI-14.31 P-136 V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1482.791482.794.0FalseNoneNoneFalseNoneFalse5931.160
3385938119246NoneI-14.44 P-138 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- etc., complete with all leadEach13641.6513641.654.0FalseNoneNoneFalseNoneFalse54566.60
3385939119246NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos.6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3385940119246NoneI-166 P-A16 V-2C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all leadNos.619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3385941119246NoneI-14.7.1 P-124 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3385942119246NoneI-13.32.1 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3385943119246NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm460.64460.6445.0FalseNoneNoneFalseNoneFalse20728.80
3385944119246NoneI-13.33.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3385945119246NoneI-13.33.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3385946119246NoneI-109 P-A15 V-2Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all leadNos.442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3385947119246NoneI-16.9 P-191 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadEach6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3385948119246NoneI-12.112.2 P-90 S.R 2018-19Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). - 15cms x 10cms ---- etc., complete with all leadEach330.4330.42.0FalseNoneNoneFalseNoneFalse660.80
3385949119246NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3385950119246NoneA.RProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards 10Cms X 7.5Cms ---- etc., complete with all leadNos.371.7371.76.0FalseNoneNoneFalseNoneFalse2230.20
3385951119246NoneA.RAir Vent Cowel 75mm ---- etc., complete with all leadNos.413.0413.01.0FalseNoneNoneFalseNoneFalse413.00
3385952119246NoneA.RAir Vent Cowel 110mm ---- etc., complete with all leadNos.590.0590.01.0FalseNoneNoneFalseNoneFalse590.00
3385953119246NoneA.RSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete with all leadNos.2183.02183.04.0FalseNoneNoneFalseNoneFalse8732.00
3385954119246NoneA.RSupply and fixing of GRP Disinfection Tank for Lab ---- etc., complete with all leadNos.118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
17194876470000NoneNoneBuildings1 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH K.R NAGARA IN MYSURU DISTRICT. (Electrical Works) (Slice-1)479236.51
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385955119247None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box. ---- etc., complete with all leadPoint326.94326.9412.0FalseNoneNoneFalseNoneFalse3923.280
3385956119247None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint460.64460.6415.0FalseNoneNoneFalseNoneFalse6909.60
3385957119247None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint674.55674.5522.0FalseNoneNoneFalseNoneFalse14840.10
3385958119247None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3385959119247None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 Way ---- etc., complete with all leadEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
3385960119247None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all leadEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3385961119247None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all leadEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3385962119247None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all leadEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3385963119247None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all leadEach387.71387.7118.0FalseNoneNoneFalseNoneFalse6978.780
3385964119247None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.5110.0FalseNoneNoneFalseNoneFalse1665.10
3385965119247None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach195.68195.683.0FalseNoneNoneFalseNoneFalse587.040
3385966119247None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3385967119247None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3385968119247None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach418.1418.118.0FalseNoneNoneFalseNoneFalse7525.80
3385969119247None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach123.97123.97109.0FalseNoneNoneFalseNoneFalse13512.730
3385970119247None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach207.83207.8355.0FalseNoneNoneFalseNoneFalse11430.650
3385971119247None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3385972119247None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3385973119247None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3385974119247None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all leadEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3385975119247NoneI-1.13Supplying And Fixing Metal Fan Box with Round Hook ---- etc., complete with all leadNo142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3385976119247None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadm80.2280.22250.0FalseNoneNoneFalseNoneFalse20055.00
3385977119247None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadm94.894.8350.0FalseNoneNoneFalseNoneFalse33180.00
3385978119247None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadm125.19125.19100.0FalseNoneNoneFalseNoneFalse12519.00
3385979119247None1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadm82.6582.65200.0FalseNoneNoneFalseNoneFalse16530.00
3385980119247None1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3385981119247None1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3385982119247None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm31.631.6225.0FalseNoneNoneFalseNoneFalse7110.00
3385983119247None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm51.0551.05750.0FalseNoneNoneFalseNoneFalse38287.50
3385984119247None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm76.5776.57300.0FalseNoneNoneFalseNoneFalse22971.00
3385985119247None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3385986119247None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure 12 Way SP & N ---- etc., complete with all leadEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3385987119247None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all leadEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3385988119247None5.20.8Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boar 32-40 Amps 4 pole ---- etc., complete with all leadEach6255.666255.661.0FalseNoneNoneFalseNoneFalse6255.660
3385989119247NoneI-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ---- etc., complete with all leadKm169605.42169605.420.05FalseNoneNoneFalseNoneFalse8480.2710
3385990119247NoneI-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm25384.8425384.840.05FalseNoneNoneFalseNoneFalse1269.2420
3385991119247NoneI-29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil ---- etc., complete with all leadCum472.79472.7950.0FalseNoneNoneFalseNoneFalse23639.50
3385992119247NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3385993119247None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
3385994119247None11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6327.0FalseNoneNoneFalseNoneFalse22643.010
3385995119247None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.6310.0FalseNoneNoneFalseNoneFalse10756.30
3385996119247None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3385997119247NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3385998119247None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3385999119247None5.40.1Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3386000119247None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm ---- etc., complete with all leadm370.7370.710.0FalseNoneNoneFalseNoneFalse3707.00
3386001119247None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.8410.0FalseNoneNoneFalseNoneFalse9188.40
3386002119247None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 ka ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3386003119247None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- etc., complete with all leadEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3386004119247None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3386005119247None5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3386006119247None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6 ---- etc., complete with all leadEach409.59409.599.0FalseNoneNoneFalseNoneFalse3686.310
3386007119247None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket ---- etc., complete with all leadEach189.6189.64.0FalseNoneNoneFalseNoneFalse758.40
3386008119247NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all leadm46.1946.19225.0FalseNoneNoneFalseNoneFalse10392.750
3386009119247None8.10.1Supplying & fixing of I/O socket with back box. Single I/O ---- etc., complete with all leadEach595.55595.559.0FalseNoneNoneFalseNoneFalse5359.950
3386010119247None8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager (85/11.4) 4U with 450mm depth ---- etc., complete with all leadEach5945.745945.741.0FalseNoneNoneFalseNoneFalse5945.740
3386011119247None8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc., complete with all leadEach7827.187827.181.0FalseNoneNoneFalseNoneFalse7827.180
3386012119247None8.11.2Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all leadEach312.36312.369.0FalseNoneNoneFalseNoneFalse2811.240
3386013119247None8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., complete with all leadEach3706.973706.971.0FalseNoneNoneFalseNoneFalse3706.970
3386014119247None8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair ---- etc., complete with all leadRmtr419.31419.311.0FalseNoneNoneFalseNoneFalse419.310
3386015119247None8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm25.5225.52100.0FalseNoneNoneFalseNoneFalse2552.00
17194876480000NoneNoneBuildings2 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH T.NARASIPURA IN MYSURU DISTRICT. (Civil Works) (Slice-2)4167301.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386016119248NoneI-2.5A P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle. ---- etc., complete with all leadSqm477.65477.652.17FalseNoneNoneFalseNoneFalse1036.50050
3386017119248NoneI-1.12 P-8 V-1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.4665.25FalseNoneNoneFalseNoneFalse7533.7650
3386018119248NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.9799.14FalseNoneNoneFalseNoneFalse12290.38580
3386019119248NoneI-1.15.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. ---- etc., complete with all leadCum441.19441.1910.25FalseNoneNoneFalseNoneFalse4522.19750
3386020119248NoneI-1.1B P-5 V-3Loading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 10 m3 ) ---- etc., complete with all leadCum144.63144.6360.25FalseNoneNoneFalseNoneFalse8713.95750
3386021119248NoneI-1.9 P-34 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.399.91FalseNoneNoneFalseNoneFalse32300.9030
3386022119248NoneI-1.8 P-33 V-1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials,usage & all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.164.91FalseNoneNoneFalseNoneFalse37394.6510
3386023119248NoneI-2.1.3 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all leadCum7279.037279.0329.86FalseNoneNoneFalseNoneFalse217351.83580
3386024119248NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all leadCum8316.848316.8418.12FalseNoneNoneFalseNoneFalse150701.14080
3386025119248NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all leadCum8316.848316.842.59FalseNoneNoneFalseNoneFalse21540.61560
3386026119248NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS ---- etc., complete with all leadCum13698.7713698.779.0FalseNoneNoneFalseNoneFalse123288.930
3386027119248NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, RCC SLAB ---- etc., complete with all leadCum12087.1512087.1537.61FalseNoneNoneFalseNoneFalse454597.71150
3386028119248NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS, LINTELS ---- etc., complete with all leadCum12892.9612892.9613.17FalseNoneNoneFalseNoneFalse169800.28320
3386029119248NoneI-2.1.4 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all leadCum7556.147556.143.35FalseNoneNoneFalseNoneFalse25313.0690
3386030119248NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ Epoxy ---- etc., complete with all leadNo.247.94247.9410.0FalseNoneNoneFalseNoneFalse2479.40
3386031119248NoneI-8.16a P-55 V-2Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- etc., complete with all leadSqm1504.671504.674.5FalseNoneNoneFalseNoneFalse6771.0150
3386032119248NoneI-2.11 P-84 V-2Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings ---- etc., complete with all leadTonne108726.04108726.045.95FalseNoneNoneFalseNoneFalse646919.9380
3386033119248NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS. (P. No. 14/ I.No. 4.21 of PWD 2018-19) ---- etc., complete with all leadRmtr40.1140.1154.0FalseNoneNoneFalseNoneFalse2165.940
3386034119248NoneI-5.4 P-9 V-2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.1920.82FalseNoneNoneFalseNoneFalse161671.25580
3386035119248NoneI-6.32 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17164.48FalseNoneNoneFalseNoneFalse261880.12160
3386036119248NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.867.33FalseNoneNoneFalseNoneFalse90343.3940
3386037119248NoneI-12.13.1 P-100 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.750.99FalseNoneNoneFalseNoneFalse118898.75250
3386038119248NoneI-12.51 P-104 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.8512.0FalseNoneNoneFalseNoneFalse14818.20
3386039119248NoneI-12.60 P-105 V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.612.0FalseNoneNoneFalseNoneFalse15343.20
3386040119248NoneI-12.61 P-105 V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos1203.251203.2512.0FalseNoneNoneFalseNoneFalse14439.00
3386041119248NoneI-12.62 P-105 V-2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.0524.0FalseNoneNoneFalseNoneFalse6913.20
3386042119248NoneI-12.63 P-107 V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos158.0158.024.0FalseNoneNoneFalseNoneFalse3792.00
3386043119248NoneI-12.64 P-107 V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.8512.0FalseNoneNoneFalseNoneFalse802.20
3386044119248NoneI-12.75.1 P-107 V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2424.0FalseNoneNoneFalseNoneFalse8021.760
3386045119248NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9272.0FalseNoneNoneFalseNoneFalse5250.240
3386046119248NoneI-15.37 P-117 S.R 2018-19KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment) ---- etc., complete with all leadRmtr34.0334.0377.6FalseNoneNoneFalseNoneFalse2640.7280
3386047119248NoneI-12.57.6 P-105 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.564037.5628.56FalseNoneNoneFalseNoneFalse115312.71360
3386048119248NoneI-12.90 P-110 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- etc., complete with all leadSqm8184.58184.527.0FalseNoneNoneFalseNoneFalse220981.50
3386049119248NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- etc., complete with all leadSqm6950.876950.871.44FalseNoneNoneFalseNoneFalse10009.25280
3386050119248NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19597.24FalseNoneNoneFalseNoneFalse121950.43560
3386051119248NoneI-12.96 P-112 V-2Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadm781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
3386052119248NoneI-12.97.1 P-112 V-2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness. ---- etc., complete with all leadSqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
3386053119248NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.9612.0FalseNoneNoneFalseNoneFalse16247.520
3386054119248NoneI-11.25.2 P-84 V-2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge ---- etc., complete with all leadKgs165.29165.29241.92FalseNoneNoneFalseNoneFalse39986.95680
3386055119248NoneI-11.35.1.1 P-86 V-2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadKg549.36549.3654.0FalseNoneNoneFalseNoneFalse29665.440
3386056119248NoneI-11.37.1 P-89 V-2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm1200.821200.827.2FalseNoneNoneFalseNoneFalse8645.9040
3386057119248NoneI-8.10 P-41 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm320.56320.56142.71FalseNoneNoneFalseNoneFalse45747.11760
3386058119248NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm530.22530.22317.43FalseNoneNoneFalseNoneFalse168307.73460
3386059119248NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.54294.25FalseNoneNoneFalseNoneFalse35763.1450
3386060119248NoneI-8.8 P-42 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm563.64563.64222.9FalseNoneNoneFalseNoneFalse125635.3560
3386061119248NoneI-8.16a P43 V-2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide. ---- etc., complete with all leadRmtr46.1946.19375.0FalseNoneNoneFalseNoneFalse17321.250
3386062119248NoneI-10.5.2 P-69 S.R 2018-19Bore Packing : filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulation on the bore. including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm262.53262.5310.0FalseNoneNoneFalseNoneFalse2625.30
3386063119248NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.263.2256.0FalseNoneNoneFalseNoneFalse16179.20
3386064119248NoneI-9.21.2 P-62 V-2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm. ---- etc., complete with all leadSqm1504.671504.67158.92FalseNoneNoneFalseNoneFalse239122.15640
3386065119248NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm358.54358.5442.84FalseNoneNoneFalseNoneFalse15359.85360
3386066119248NoneI-9.11 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm926.13926.138.34FalseNoneNoneFalseNoneFalse7723.92420
3386067119248NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1260.371260.3742.84FalseNoneNoneFalseNoneFalse53994.25080
3386068119248NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm192.94192.94588.51FalseNoneNoneFalseNoneFalse113547.11940
3386069119248NoneI-8.31 P-46 V-2Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm270.43270.43222.9FalseNoneNoneFalseNoneFalse60278.8470
3386070119248NoneI-8.34.3 P-47 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7728.44FalseNoneNoneFalseNoneFalse1728.29880
3386071119248NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7728.44FalseNoneNoneFalseNoneFalse3975.05880
3386072119248NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4264.4268.54FalseNoneNoneFalseNoneFalse4415.34680
3386073119248NoneI-8.47 P-49 V-2Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm164.08164.0868.54FalseNoneNoneFalseNoneFalse11246.04320
3386074119248NoneI-10.1.7 P-113 V-5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm499.53499.5324.0FalseNoneNoneFalseNoneFalse11988.720
17194876480000NoneNoneBuildings2 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH T.NARASIPURA IN MYSURU DISTRICT. (Water Supply & Sanitary Works) (Slice-2)322104.19
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386075119249NoneI-14.28.2.2 P-136 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40mm dia pipes ---- etc., complete with all leadEach111.82111.828.0FalseNoneNoneFalseNoneFalse894.560
3386076119249NoneI-16.7.4 P-191 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete with all leadm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3386077119249NoneI-10.1.5 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm267.39267.3940.0FalseNoneNoneFalseNoneFalse10695.60
3386078119249NoneI-10.1.7 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for : PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm499.53499.5335.0FalseNoneNoneFalseNoneFalse17483.550
3386079119249NoneI-13.47 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3386080119249NoneI-14.31 P-136 V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1482.791482.794.0FalseNoneNoneFalseNoneFalse5931.160
3386081119249NoneI-14.44 P-138 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- etc., complete with all leadEach13641.6513641.654.0FalseNoneNoneFalseNoneFalse54566.60
3386082119249NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos.6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3386083119249NoneI-166 P-A16 V-2C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all leadNos.638.09638.094.0FalseNoneNoneFalseNoneFalse2552.360
3386084119249NoneI-14.7.1 P-124 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3386085119249NoneI-13.32.1 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3386086119249NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm460.64460.6445.0FalseNoneNoneFalseNoneFalse20728.80
3386087119249NoneI-13.33.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3386088119249NoneI-13.33.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3386089119249NoneI-109 P-A15 V-2Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all leadNos.455.78455.784.0FalseNoneNoneFalseNoneFalse1823.120
3386090119249NoneI-16.9 P-191 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadEach6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3386091119249NoneI-12.112.2 P-90 S.R 2018-19Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). - 15cms x 10cms ---- etc., complete with all leadEach330.4330.42.0FalseNoneNoneFalseNoneFalse660.80
3386092119249NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3386093119249NoneA.RProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards 10Cms X 7.5Cms ---- etc., complete with all leadNos.371.7371.76.0FalseNoneNoneFalseNoneFalse2230.20
3386094119249NoneA.RAir Vent Cowel 75mm ---- etc., complete with all leadNos.413.0413.01.0FalseNoneNoneFalseNoneFalse413.00
3386095119249NoneA.RAir Vent Cowel 110mm ---- etc., complete with all leadNos.590.0590.01.0FalseNoneNoneFalseNoneFalse590.00
3386096119249NoneA.RSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete with all leadNos.2183.02183.04.0FalseNoneNoneFalseNoneFalse8732.00
3386097119249NoneA.RSupply and fixing of GRP Disinfection Tank for Lab ---- etc., complete with all leadNos.118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
17194876480000NoneNoneBuildings2 CONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH T.NARASIPURA IN MYSURU DISTRICT. (Electrical Works) (Slice-2)479236.51
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386098119250None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box. ---- etc., complete with all leadPoint326.94326.9412.0FalseNoneNoneFalseNoneFalse3923.280
3386099119250None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint460.64460.6415.0FalseNoneNoneFalseNoneFalse6909.60
3386100119250None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint674.55674.5522.0FalseNoneNoneFalseNoneFalse14840.10
3386101119250None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3386102119250None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 Way ---- etc., complete with all leadEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
3386103119250None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all leadEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3386104119250None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all leadEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3386105119250None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all leadEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3386106119250None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all leadEach387.71387.7118.0FalseNoneNoneFalseNoneFalse6978.780
3386107119250None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.5110.0FalseNoneNoneFalseNoneFalse1665.10
3386108119250None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach195.68195.683.0FalseNoneNoneFalseNoneFalse587.040
3386109119250None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3386110119250None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3386111119250None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach418.1418.118.0FalseNoneNoneFalseNoneFalse7525.80
3386112119250None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach123.97123.97109.0FalseNoneNoneFalseNoneFalse13512.730
3386113119250None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach207.83207.8355.0FalseNoneNoneFalseNoneFalse11430.650
3386114119250None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3386115119250None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3386116119250None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3386117119250None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all leadEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3386118119250NoneI-1.13Supplying And Fixing Metal Fan Box with Round Hook ---- etc., complete with all leadNo142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3386119119250None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadm80.2280.22250.0FalseNoneNoneFalseNoneFalse20055.00
3386120119250None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadm94.894.8350.0FalseNoneNoneFalseNoneFalse33180.00
3386121119250None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadm125.19125.19100.0FalseNoneNoneFalseNoneFalse12519.00
3386122119250None1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadm82.6582.65200.0FalseNoneNoneFalseNoneFalse16530.00
3386123119250None1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3386124119250None1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3386125119250None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm31.631.6225.0FalseNoneNoneFalseNoneFalse7110.00
3386126119250None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm51.0551.05750.0FalseNoneNoneFalseNoneFalse38287.50
3386127119250None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm76.5776.57300.0FalseNoneNoneFalseNoneFalse22971.00
3386128119250None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3386129119250None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure 12 Way SP & N ---- etc., complete with all leadEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3386130119250None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all leadEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3386131119250None5.20.8Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boar 32-40 Amps 4 pole ---- etc., complete with all leadEach6255.666255.661.0FalseNoneNoneFalseNoneFalse6255.660
3386132119250NoneI-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ---- etc., complete with all leadKm169605.42169605.420.05FalseNoneNoneFalseNoneFalse8480.2710
3386133119250NoneI-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm25384.8425384.840.05FalseNoneNoneFalseNoneFalse1269.2420
3386134119250NoneI-29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil ---- etc., complete with all leadCum472.79472.7950.0FalseNoneNoneFalseNoneFalse23639.50
3386135119250NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3386136119250None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
3386137119250None11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6327.0FalseNoneNoneFalseNoneFalse22643.010
3386138119250None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.6310.0FalseNoneNoneFalseNoneFalse10756.30
3386139119250None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3386140119250NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3386141119250None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3386142119250None5.40.1Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3386143119250None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm ---- etc., complete with all leadm370.7370.710.0FalseNoneNoneFalseNoneFalse3707.00
3386144119250None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.8410.0FalseNoneNoneFalseNoneFalse9188.40
3386145119250None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 ka ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3386146119250None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- etc., complete with all leadEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3386147119250None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3386148119250None5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3386149119250None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6 ---- etc., complete with all leadEach409.59409.599.0FalseNoneNoneFalseNoneFalse3686.310
3386150119250None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket ---- etc., complete with all leadEach189.6189.64.0FalseNoneNoneFalseNoneFalse758.40
3386151119250NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all leadm46.1946.19225.0FalseNoneNoneFalseNoneFalse10392.750
3386152119250None8.10.1Supplying & fixing of I/O socket with back box. Single I/O ---- etc., complete with all leadEach595.55595.559.0FalseNoneNoneFalseNoneFalse5359.950
3386153119250None8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager (85/11.4) 4U with 450mm depth ---- etc., complete with all leadEach5945.745945.741.0FalseNoneNoneFalseNoneFalse5945.740
3386154119250None8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc., complete with all leadEach7827.187827.181.0FalseNoneNoneFalseNoneFalse7827.180
3386155119250None8.11.2Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all leadEach312.36312.369.0FalseNoneNoneFalseNoneFalse2811.240
3386156119250None8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., complete with all leadEach3706.973706.971.0FalseNoneNoneFalseNoneFalse3706.970
3386157119250None8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair ---- etc., complete with all leadRmtr419.31419.311.0FalseNoneNoneFalseNoneFalse419.310
3386158119250None8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm25.5225.52100.0FalseNoneNoneFalseNoneFalse2552.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194876490000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194876490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194876490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194876490000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194876490000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194878140000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17194880200000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17194880320000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194880430000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17194880550000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17194880680000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17194880800000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17194880970000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17194881080000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17194881360000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17194881480000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17194881630000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17194881790000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17194881900000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17194882020000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17194882150000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17194882260000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17194882370000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17194882490000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.49.70 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.4.80 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.3.30 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 280.00 Cum,2)RCC and PCC 180.00 Cum 3)Steel Reinforcement for RCC work 10.00 Tonnes 4)Cement Concrete Block Masonry/BBM/Solid Block Masonry, Load bearing wall 450.00 Sqm 5)Flooring /Dadooing(Vitrified/Granite/Ceramic/Cement concrete/ cladding/ dadooing) 350.00 Sqm, 6) Plastering 1200.00 Sqm,7)Painting 1500.00 Sqm 8) M.S.Grill 970.00Kg Note -The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 6 months. Note. The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing commitments and Bids submitted for the works certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneKPWD Class-III & Above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PWD Registration Certificate issued by Chief Engineer, PWD
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 One 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years-1 One.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates to be furnished
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.99.40 Lakhs. Note: a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turn over and balance sheet, Proft and loss Certified balance sheet audited CA Certificate by Chartered Accountant
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.30.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by a Scheduled/Nationalised Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Work done certificate issued by not below the rank of Executive Engineer.TrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their nameTrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
KPWD class-III and above Registration Certificate issued by Competant AuthorityTrueTechnical Bid
Annual Turnover Certificate & profit & loss Certified balance sheet issued by Chartered AccountantTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone