createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719474595602
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4970.00
emd299000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 16:00:00
tenderQueryClose03-07-2024 16:00:00
technicalBidOpen12-07-2024 16:30:10
publishedDate27-06-2024 18:06:52
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate04-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPraveen B A Technical Assistanat
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1719474595636
version14
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT510
titleConstruction of Block level public health laboratory (BLPHL) at (1)GH Tarikere, (2) GH Kadur in Chikkamagaluru District and (3) GH Sakleshpura & 4)GH Alur in Hassan District.
descriptionConstruction of Block level public health laboratory (BLPHL) at (1)GH Tarikere, (2) GH Kadur in Chikkamagaluru District and (3) GH Sakleshpura & (4)GH Alur in Hassan District.
categoryWORKS
categoryTextWorks
ecv19856752.90
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount20000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/HSNCKM/BPHU/HSNCKMPKG
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194745960000NoneNoneBuildings1 Construction of Block level public health laboratory (BLPHL) at GH Tarikere in Chikkamagaluru District. (Civil Works) (Slice-1)4431379.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379670119018NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.46125.4FalseNoneNoneFalseNoneFalse14478.6840
3379671119018NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.97178.2FalseNoneNoneFalseNoneFalse22091.4540
3379672119018NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3160.38FalseNoneNoneFalseNoneFalse51850.8540
3379673119018NoneV-2 P-5 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications ---- etc., complete with all leadSqm143.42143.42200.06FalseNoneNoneFalseNoneFalse28692.60520
3379674119018NoneV-1 P-15 I-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0325.45FalseNoneNoneFalseNoneFalse185251.31350
3379675119018NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Footings ---- etc., complete with all leadCum8252.258252.2545.83FalseNoneNoneFalseNoneFalse378200.61750
3379676119018NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Footings ---- etc., complete with all leadCum8252.258252.252.61FalseNoneNoneFalseNoneFalse21538.37250
3379677119018NoneV-1 P-16 I-2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Plinth Beam ---- etc., complete with all leadCum7875.797875.798.9FalseNoneNoneFalseNoneFalse70094.5310
3379678119018NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) Columns above plinth ---- etc., complete with all leadCum14138.8714138.877.55FalseNoneNoneFalseNoneFalse106748.46850
3379679119018NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Cills ---- etc., complete with all leadCum8316.988316.980.86FalseNoneNoneFalseNoneFalse7152.60280
3379680119018NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Chajja ---- etc., complete with all leadCum12059.8412059.841.84FalseNoneNoneFalseNoneFalse22190.10560
3379681119018NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Plinth Beam, Roof Beam, Lintels ---- etc., complete with all leadCum13307.1713307.1723.16FalseNoneNoneFalseNoneFalse308194.05720
3379682119018NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) RCC Slab ---- etc., complete with all leadCum12475.4712475.4729.18FalseNoneNoneFalseNoneFalse364034.21460
3379683119018NoneV-1 P-84 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) ---- etc., complete with all leadTonne108726.04108726.047.91FalseNoneNoneFalseNoneFalse860022.97640
3379684119018NoneV-2 P-17 I-6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17231.25FalseNoneNoneFalseNoneFalse368189.31250
3379685119018NoneV-2 P-17 I-6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.853.7FalseNoneNoneFalseNoneFalse72054.660
3379686119018NoneV-2 P-87 I-11.35.2.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg693.99693.9925.2FalseNoneNoneFalseNoneFalse17488.5480
3379687119018NoneV-2 P-88 I-11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadSqm1423.231423.231.2FalseNoneNoneFalseNoneFalse1707.8760
3379688119018NoneV-2 P-88 I-11.36.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both the sids including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1194.741194.741.2FalseNoneNoneFalseNoneFalse1433.6880
3379689119018NoneV-2 P-111 I-12.86Providing & fixing of 2 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6551.016551.0136.45FalseNoneNoneFalseNoneFalse238784.31450
3379690119018NoneV-2 P-110 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.871.62FalseNoneNoneFalseNoneFalse11260.40940
3379691119018NoneV-2 P-85 I-11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc ---- etc., complete with all leadKgs222.42222.42575.91FalseNoneNoneFalseNoneFalse128093.90220
3379692119018NoneV-2 P-82 I-11.26.3Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes in cluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- etc., complete with all leadKgs222.42222.4282.5FalseNoneNoneFalseNoneFalse18349.650
3379693119018NoneV-2 P-100 I-12.13.1Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications. ---- etc., complete with all leadCum120099.75120099.750.2FalseNoneNoneFalseNoneFalse24019.950
3379694119018NoneV-2 P-106 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick Both side commercial. ---- etc., complete with all leadSqm4037.564037.5612.2FalseNoneNoneFalseNoneFalse49258.2320
3379695119018NoneV-2 P-111 I-12.93.2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately).Size 62 x 125mm ---- etc., complete with all leadSqm928.57928.5720.4FalseNoneNoneFalseNoneFalse18942.8280
3379696119018NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all leadSqm4235.674235.677.5FalseNoneNoneFalseNoneFalse31767.5250
3379697119018NoneV-2 P-105 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.854.0FalseNoneNoneFalseNoneFalse4939.40
3379698119018NoneV-2 P-69 I-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9224.0FalseNoneNoneFalseNoneFalse1750.080
3379699119018NoneV-2 P-107 I-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.964.0FalseNoneNoneFalseNoneFalse5415.840
3379700119018NoneV-2 P-107 I-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.64.0FalseNoneNoneFalseNoneFalse5114.40
3379701119018NoneV-2 P-107 I-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. Complete ---- etc., complete with all leadNos1203.251203.254.0FalseNoneNoneFalseNoneFalse4813.00
3379702119018NoneV-2 P-107 I-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.058.0FalseNoneNoneFalseNoneFalse2304.40
3379703119018NoneV-2 P-107 I-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete ---- etc., complete with all leadNos158.0158.08.0FalseNoneNoneFalseNoneFalse1264.00
3379704119018NoneV-2 P-107 I-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.854.0FalseNoneNoneFalseNoneFalse267.40
3379705119018NoneV-2 P-108 I-12.75Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2412.0FalseNoneNoneFalseNoneFalse4010.880
3379706119018NonePWD SR 18-19 P-117 I-15.37KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment) ---- etc., complete with all leadRmtr34.0334.0324.3FalseNoneNoneFalseNoneFalse826.9290
3379707119018NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ---- etc., complete with all leadSqm1391.631391.63155.7FalseNoneNoneFalseNoneFalse216676.7910
3379708119018NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- etc., complete with all leadSqm1080.491080.498.3FalseNoneNoneFalseNoneFalse8968.0670
3379709119018NoneV-2 P-71 I-10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete ---- etc., complete with all leadSqm1344.231344.2371.4FalseNoneNoneFalseNoneFalse95978.0220
3379710119018NoneV-2 P-64 I-9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications ---- etc., complete with all leadSqm6475.656475.652.7FalseNoneNoneFalseNoneFalse17484.2550
3379711119018NoneV-2 P-63 I-9.28Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications ---- etc., complete with all leadSqm5200.75200.72.5FalseNoneNoneFalseNoneFalse13001.750
3379712119018NoneV-2 P-41 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm339.1339.1144.6FalseNoneNoneFalseNoneFalse49033.860
3379713119018NoneV-2 P-41 I-8.8Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding ,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( Inside) ---- etc., complete with all leadSqm339.1339.1646.6FalseNoneNoneFalseNoneFalse219262.060
3379714119018NoneV-2 P-41 I-8.9Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) finished rough to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( outside) ---- etc., complete with all leadSqm467.93467.93323.1FalseNoneNoneFalseNoneFalse151188.1830
3379715119018NoneV-2 P-47 I-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm64.4264.4229.2FalseNoneNoneFalseNoneFalse1881.0640
3379716119018NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm139.77139.7765.0FalseNoneNoneFalseNoneFalse9085.050
3379717119018NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36791.2FalseNoneNoneFalseNoneFalse122129.6320
3379718119018NoneV-2 P-46 I-8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm211.48211.48323.1FalseNoneNoneFalseNoneFalse68329.1880
3379719119018NoneV-2 P-47 I-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7735.8FalseNoneNoneFalseNoneFalse2175.5660
3379720119018NoneV-2 P-150 I-15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm747.47747.474.8FalseNoneNoneFalseNoneFalse3587.8560
17194745960000NoneNoneBuildings2 Construction of Block level public health laboratory (BLPHL) at GH Tarikere in Chikkamagaluru District. (Water Supply & Sanitary Works) (Slice-1)192999.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379721119019NoneP-122 I.No.13.32.3 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 25 mm Dia ---- etc., complete with all leadm579.75579.7545.0FalseNoneNoneFalseNoneFalse26088.750
3379722119019NoneP-122 I.No.13.32.4 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 32 mm Dia ---- etc., complete with all leadm676.98676.9835.0FalseNoneNoneFalseNoneFalse23694.30
3379723119019NoneP-119 I.No.13.12 of Vol.2Providing and fixing brass bib cock of approved quality ---- etc., complete with all leadNos771.78771.788.0FalseNoneNoneFalseNoneFalse6174.240
3379724119019NoneP-117 I.No.13.4.1 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore ---- etc., complete with all leadNos667.25667.254.0FalseNoneNoneFalseNoneFalse2669.00
3379725119019NoneP-117 I.No.13.4.2 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore ---- etc., complete with all leadNos726.81726.814.0FalseNoneNoneFalseNoneFalse2907.240
3379726119019NoneP-131 I.No.14.1.1 of Vol.2Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5936.015936.012.0FalseNoneNoneFalseNoneFalse11872.020
3379727119019NoneP-124 I.No.13.41 of Vol.2Providing and fixing trap of self ceansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors:*100mm inlet and 100mm outlet.* Sand cast iron S&S as per IS:1729. ---- etc., complete with all leadEach1629.851629.858.0FalseNoneNoneFalseNoneFalse13038.80
3379728119019NoneP-125 I.No.13.48 of Vol.2Providing and fixingon wall face unplasticised Rigid PVC rain water pipes confirming to IS:13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for the thermal expansion,(i) Single socketed pipes 100mm diameter ---- etc., complete with all leadRmtr353.68353.6855.0FalseNoneNoneFalseNoneFalse19452.40
3379729119019NoneP.No.6 I.No.1.6.1 of Vol.1Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m ---- etc., complete with all leadCum588.25588.2515.0FalseNoneNoneFalseNoneFalse8823.750
3379730119019NoneP.No.191 I.No.16.10 of Vol.5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNos5148.435148.435.0FalseNoneNoneFalseNoneFalse25742.150
3379731119019NoneP-160, I-1.10 of Vol 1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.468.0FalseNoneNoneFalseNoneFalse1555.680
3379732119019NoneP-123, I-13.36 of Vol 2Cutting holes upto 30X30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks. ---- etc., complete with all leadEach392.57392.5720.0FalseNoneNoneFalseNoneFalse7851.40
3379733119019NoneP-123, I-13.37 of Vol 2Cutting holes upto 15X15cm in RCC floors and roofs for passing drain pipe etc.,and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size)including finishing complete so as to make it leak proof. ---- etc., complete with all leadEach380.42380.4210.0FalseNoneNoneFalseNoneFalse3804.20
3379734119019NoneP-120 I-13.22.2 of Vol 2Providing and fixing PTMT grating of approved quality and colour, Rectangular type with openable circular lid ---- etc., complete with all leadEach245.51245.5110.0FalseNoneNoneFalseNoneFalse2455.10
3379735119019NoneP-20 I-13.23.2of Vol 2Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 20 mm nominal bore, 120 mm long, weighing not less than 198 g ---- etc., complete with all leadNos300.2300.21.0FalseNoneNoneFalseNoneFalse300.20
3379736119019NoneP-119 I-13.15 of Vol 2Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 ---- etc., complete with all leadNos881.17881.171.0FalseNoneNoneFalseNoneFalse881.170
3379737119019NoneP-119 I-13.16 of Vol 2Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all leadNos753.55753.5510.0FalseNoneNoneFalseNoneFalse7535.50
3379738119019NoneP-123 I-13.34 of Vol 2Providing and placing on terrace(at all floor levels), polyethylene water storage tank,IS:120701 marked,with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank ---- etc., complete with all leadl10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3379739119019NoneP-123 I-13.39 of Vol 2Providing and fixing square mouth S.W.gully trap class SP-1 complete with C.I.grating,brick masonry camber 150X 100 mm size P type with non modular bcommon burnt clay bricks of designation 3.5 & with water tight.C.I cover with frame of 300X300 mm size (inside)the weight of the cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design ---- etc., complete with all leadEach3136.953136.952.0FalseNoneNoneFalseNoneFalse6273.90
17194745960000NoneNoneBuildings1 Construction of Block level public health laboratory (BLPHL) at GH Tarikere in Chikkamagaluru District. (Electrical Works) (Slice-1)366737.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379740119020None2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Short point upto 3 mts from tapping point to out let via switch ---- etc., complete with all leadPoint326.94326.9422.0FalseNoneNoneFalseNoneFalse7192.680
3379741119020None2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint460.64460.6416.0FalseNoneNoneFalseNoneFalse7370.240
3379742119020None2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3379743119020None3.4.2Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 way ---- etc., complete with all leadEach193.25193.2513.0FalseNoneNoneFalseNoneFalse2512.250
3379744119020None3.4.3Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5 way ---- etc., complete with all leadEach215.13215.1312.0FalseNoneNoneFalseNoneFalse2581.560
3379745119020None3.4.4Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
3379746119020None3.4.5Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 way ---- etc., complete with all leadEach317.22317.2219.0FalseNoneNoneFalseNoneFalse6027.180
3379747119020None3.4.7Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 way ---- etc., complete with all leadEach441.19441.197.0FalseNoneNoneFalseNoneFalse3088.330
3379748119020None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module ---- etc., complete with all leadEach195.68195.6813.0FalseNoneNoneFalseNoneFalse2543.840
3379749119020None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module ---- etc., complete with all leadEach212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
3379750119020None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
3379751119020None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module ---- etc., complete with all leadEach345.17345.1719.0FalseNoneNoneFalseNoneFalse6558.230
3379752119020None3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 16 module ---- etc., complete with all leadEach482.51482.517.0FalseNoneNoneFalseNoneFalse3377.570
3379753119020None3.6.1Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch ---- etc., complete with all leadEach123.97123.9784.0FalseNoneNoneFalseNoneFalse10413.480
3379754119020None3.6.3Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets ---- etc., complete with all leadEach207.83207.8316.0FalseNoneNoneFalseNoneFalse3325.280
3379755119020None3.6.4Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's ---- etc., complete with all leadEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3379756119020None3.6.7Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 129316 amps one way switch ---- etc., complete with all leadEach218.77218.7734.0FalseNoneNoneFalseNoneFalse7438.180
3379757119020None3.6.10Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets ---- etc., complete with all leadEach286.83286.8334.0FalseNoneNoneFalseNoneFalse9752.220
3379758119020None3.6.9Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch ---- etc., complete with all leadEach396.22396.223.0FalseNoneNoneFalseNoneFalse1188.660
3379759119020NoneI-1.13Supply and fixing one metal Fan box with round hook ---- etc., complete with all leadEach142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3379760119020None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr80.2280.22130.0FalseNoneNoneFalseNoneFalse10428.60
3379761119020None1.3.1Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 19/20 mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.65250.0FalseNoneNoneFalseNoneFalse20662.50
3379762119020None1.3.2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 25 mm dia ---- etc., complete with all leadMtr96.0296.02220.0FalseNoneNoneFalseNoneFalse21124.40
3379763119020None2.3.2Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 1.5 Sq.mm ---- etc., complete with all leadMtr31.631.6650.0FalseNoneNoneFalseNoneFalse20540.00
3379764119020None2.3.3Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 2.5 sq.mm ---- etc., complete with all leadMtr51.0551.05450.0FalseNoneNoneFalseNoneFalse22972.50
3379765119020None2.3.4Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 4 sq.mm ---- etc., complete with all leadMtr76.5776.57100.0FalseNoneNoneFalseNoneFalse7657.00
3379766119020None2.3.5Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 6 sq.mm ---- etc., complete with all leadMtr111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
3379767119020None2.3.6Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.10 sq.mm ---- etc., complete with all leadMtr202.97202.9760.0FalseNoneNoneFalseNoneFalse12178.20
3379768119020None5.19.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.12 Way SP & N ---- etc., complete with all leadEach2830.672830.672.0FalseNoneNoneFalseNoneFalse5661.340
3379769119020None5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps SP ---- etc., complete with all leadEach504.39504.3918.0FalseNoneNoneFalseNoneFalse9079.020
3379770119020None5.18.4Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.186.0FalseNoneNoneFalseNoneFalse5389.080
3379771119020None5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
3379772119020None32.08 V-61.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) ---- etc., complete with all leadKm218582.4218582.40.1FalseNoneNoneFalseNoneFalse21858.240
3379773119020None21.05 V-6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staff ---- etc., complete with all leadKm25384.8425384.840.1FalseNoneNoneFalseNoneFalse2538.4840
3379774119020None48.05( V-6)2021-22GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia ---- etc., complete with all leadMtr393.79393.795.0FalseNoneNoneFalseNoneFalse1968.950
3379775119020NoneI-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNo4266.054266.052.0FalseNoneNoneFalseNoneFalse8532.10
3379776119020None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip ---- etc., complete with all leadMtr99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
3379777119020NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all leadMtr46.1946.1945.0FalseNoneNoneFalseNoneFalse2078.550
3379778119020None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5242000.0FalseNoneNoneFalseNoneFalse21840.00
3379779119020None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3379780119020None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr370.7370.73.0FalseNoneNoneFalseNoneFalse1112.10
3379781119020None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3379782119020None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.166.0FalseNoneNoneFalseNoneFalse22518.960
3379783119020NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3379784119020NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3379785119020NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
17194745960000NoneNoneBuildings2 Construction of Block level public health laboratory (BLPHL) at GH Kadur in Chikkamagaluru District. (Civil Works) (Slice-2)4431379.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379786119021NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.46125.4FalseNoneNoneFalseNoneFalse14478.6840
3379787119021NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.97178.2FalseNoneNoneFalseNoneFalse22091.4540
3379788119021NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3160.38FalseNoneNoneFalseNoneFalse51850.8540
3379789119021NoneV-2 P-5 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications ---- etc., complete with all leadSqm143.42143.42200.06FalseNoneNoneFalseNoneFalse28692.60520
3379790119021NoneV-1 P-15 I-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0325.45FalseNoneNoneFalseNoneFalse185251.31350
3379791119021NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Footings ---- etc., complete with all leadCum8252.258252.2545.83FalseNoneNoneFalseNoneFalse378200.61750
3379792119021NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Footings ---- etc., complete with all leadCum8252.258252.252.61FalseNoneNoneFalseNoneFalse21538.37250
3379793119021NoneV-1 P-16 I-2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Plinth Beam ---- etc., complete with all leadCum7875.797875.798.9FalseNoneNoneFalseNoneFalse70094.5310
3379794119021NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) Columns above plinth ---- etc., complete with all leadCum14138.8714138.877.55FalseNoneNoneFalseNoneFalse106748.46850
3379795119021NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Cills ---- etc., complete with all leadCum8316.988316.980.86FalseNoneNoneFalseNoneFalse7152.60280
3379796119021NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Chajja ---- etc., complete with all leadCum12059.8412059.841.84FalseNoneNoneFalseNoneFalse22190.10560
3379797119021NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Plinth Beam, Roof Beam, Lintels ---- etc., complete with all leadCum13307.1713307.1723.16FalseNoneNoneFalseNoneFalse308194.05720
3379798119021NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) RCC Slab ---- etc., complete with all leadCum12475.4712475.4729.18FalseNoneNoneFalseNoneFalse364034.21460
3379799119021NoneV-1 P-84 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) ---- etc., complete with all leadTonne108726.04108726.047.91FalseNoneNoneFalseNoneFalse860022.97640
3379800119021NoneV-2 P-17 I-6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17231.25FalseNoneNoneFalseNoneFalse368189.31250
3379801119021NoneV-2 P-17 I-6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.853.7FalseNoneNoneFalseNoneFalse72054.660
3379802119021NoneV-2 P-87 I-11.35.2.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg693.99693.9925.2FalseNoneNoneFalseNoneFalse17488.5480
3379803119021NoneV-2 P-88 I-11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadSqm1423.231423.231.2FalseNoneNoneFalseNoneFalse1707.8760
3379804119021NoneV-2 P-88 I-11.36.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both the sids including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1194.741194.741.2FalseNoneNoneFalseNoneFalse1433.6880
3379805119021NoneV-2 P-111 I-12.86Providing & fixing of 2 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6551.016551.0136.45FalseNoneNoneFalseNoneFalse238784.31450
3379806119021NoneV-2 P-110 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.871.62FalseNoneNoneFalseNoneFalse11260.40940
3379807119021NoneV-2 P-85 I-11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc ---- etc., complete with all leadKgs222.42222.42575.91FalseNoneNoneFalseNoneFalse128093.90220
3379808119021NoneV-2 P-82 I-11.26.3Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes in cluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- etc., complete with all leadKgs222.42222.4282.5FalseNoneNoneFalseNoneFalse18349.650
3379809119021NoneV-2 P-100 I-12.13.1Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications. ---- etc., complete with all leadCum120099.75120099.750.2FalseNoneNoneFalseNoneFalse24019.950
3379810119021NoneV-2 P-106 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick Both side commercial. ---- etc., complete with all leadSqm4037.564037.5612.2FalseNoneNoneFalseNoneFalse49258.2320
3379811119021NoneV-2 P-111 I-12.93.2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately).Size 62 x 125mm ---- etc., complete with all leadSqm928.57928.5720.4FalseNoneNoneFalseNoneFalse18942.8280
3379812119021NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all leadSqm4235.674235.677.5FalseNoneNoneFalseNoneFalse31767.5250
3379813119021NoneV-2 P-105 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.854.0FalseNoneNoneFalseNoneFalse4939.40
3379814119021NoneV-2 P-69 I-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9224.0FalseNoneNoneFalseNoneFalse1750.080
3379815119021NoneV-2 P-107 I-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.964.0FalseNoneNoneFalseNoneFalse5415.840
3379816119021NoneV-2 P-107 I-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.64.0FalseNoneNoneFalseNoneFalse5114.40
3379817119021NoneV-2 P-107 I-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. Complete ---- etc., complete with all leadNos1203.251203.254.0FalseNoneNoneFalseNoneFalse4813.00
3379818119021NoneV-2 P-107 I-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.058.0FalseNoneNoneFalseNoneFalse2304.40
3379819119021NoneV-2 P-107 I-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete ---- etc., complete with all leadNos158.0158.08.0FalseNoneNoneFalseNoneFalse1264.00
3379820119021NoneV-2 P-107 I-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.854.0FalseNoneNoneFalseNoneFalse267.40
3379821119021NoneV-2 P-108 I-12.75Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2412.0FalseNoneNoneFalseNoneFalse4010.880
3379822119021NonePWD SR 18-19 P-117 I-15.37KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment) ---- etc., complete with all leadRmtr34.0334.0324.3FalseNoneNoneFalseNoneFalse826.9290
3379823119021NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ---- etc., complete with all leadSqm1391.631391.63155.7FalseNoneNoneFalseNoneFalse216676.7910
3379824119021NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- etc., complete with all leadSqm1080.491080.498.3FalseNoneNoneFalseNoneFalse8968.0670
3379825119021NoneV-2 P-71 I-10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete ---- etc., complete with all leadSqm1344.231344.2371.4FalseNoneNoneFalseNoneFalse95978.0220
3379826119021NoneV-2 P-64 I-9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications ---- etc., complete with all leadSqm6475.656475.652.7FalseNoneNoneFalseNoneFalse17484.2550
3379827119021NoneV-2 P-63 I-9.28Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications ---- etc., complete with all leadSqm5200.75200.72.5FalseNoneNoneFalseNoneFalse13001.750
3379828119021NoneV-2 P-41 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm339.1339.1144.6FalseNoneNoneFalseNoneFalse49033.860
3379829119021NoneV-2 P-41 I-8.8Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding ,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( Inside) ---- etc., complete with all leadSqm339.1339.1646.6FalseNoneNoneFalseNoneFalse219262.060
3379830119021NoneV-2 P-41 I-8.9Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) finished rough to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( outside) ---- etc., complete with all leadSqm467.93467.93323.1FalseNoneNoneFalseNoneFalse151188.1830
3379831119021NoneV-2 P-47 I-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm64.4264.4229.2FalseNoneNoneFalseNoneFalse1881.0640
3379832119021NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm139.77139.7765.0FalseNoneNoneFalseNoneFalse9085.050
3379833119021NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36791.2FalseNoneNoneFalseNoneFalse122129.6320
3379834119021NoneV-2 P-46 I-8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm211.48211.48323.1FalseNoneNoneFalseNoneFalse68329.1880
3379835119021NoneV-2 P-47 I-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7735.8FalseNoneNoneFalseNoneFalse2175.5660
3379836119021NoneV-2 P-150 I-15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm747.47747.474.8FalseNoneNoneFalseNoneFalse3587.8560
17194745960000NoneNoneBuildings2 Construction of Block level public health laboratory (BLPHL) at GH Kadur in Chikkamagaluru District. (Water Supply & Sanitary Works) (Slice-2)192999.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379837119022NoneP-122 I.No.13.32.3 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 25 mm Dia ---- etc., complete with all leadm579.75579.7545.0FalseNoneNoneFalseNoneFalse26088.750
3379838119022NoneP-122 I.No.13.32.4 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 32 mm Dia ---- etc., complete with all leadm676.98676.9835.0FalseNoneNoneFalseNoneFalse23694.30
3379839119022NoneP-119 I.No.13.12 of Vol.2Providing and fixing brass bib cock of approved quality ---- etc., complete with all leadNos771.78771.788.0FalseNoneNoneFalseNoneFalse6174.240
3379840119022NoneP-117 I.No.13.4.1 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore ---- etc., complete with all leadNos667.25667.254.0FalseNoneNoneFalseNoneFalse2669.00
3379841119022NoneP-117 I.No.13.4.2 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore ---- etc., complete with all leadNos726.81726.814.0FalseNoneNoneFalseNoneFalse2907.240
3379842119022NoneP.No.131 I.No.14.1.1 of Vol.2Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5936.015936.012.0FalseNoneNoneFalseNoneFalse11872.020
3379843119022NoneP-124 I.No.13.41 of Vol.2Providing and fixing trap of self ceansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors:*100mm inlet and 100mm outlet.* Sand cast iron S&S as per IS:1729. ---- etc., complete with all leadEach1629.851629.858.0FalseNoneNoneFalseNoneFalse13038.80
3379844119022NoneP-125 I.No.13.48 of Vol.2Providing and fixingon wall face unplasticised Rigid PVC rain water pipes confirming to IS:13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for the thermal expansion,(i) Single socketed pipes 100mm diameter ---- etc., complete with all leadRmtr353.68353.6855.0FalseNoneNoneFalseNoneFalse19452.40
3379845119022NoneP.No.6 I.No.1.6.1 of Vol.1Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m ---- etc., complete with all leadCum588.25588.2515.0FalseNoneNoneFalseNoneFalse8823.750
3379846119022NoneP.No.191 I.No.16.10 of Vol.5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNos5148.435148.435.0FalseNoneNoneFalseNoneFalse25742.150
3379847119022NoneP-160, I-1.10 of Vol 1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.468.0FalseNoneNoneFalseNoneFalse1555.680
3379848119022NoneP-123, I-13.36 of Vol 2Cutting holes upto 30X30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks. ---- etc., complete with all leadEach392.57392.5720.0FalseNoneNoneFalseNoneFalse7851.40
3379849119022NoneP-123, I-13.37 of Vol 2Cutting holes upto 15X15cm in RCC floors and roofs for passing drain pipe etc.,and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size)including finishing complete so as to make it leak proof. ---- etc., complete with all leadEach380.42380.4210.0FalseNoneNoneFalseNoneFalse3804.20
3379850119022NoneP-120 I-13.22.2 of Vol 2Providing and fixing PTMT grating of approved quality and colour, Rectangular type with openable circular lid ---- etc., complete with all leadEach245.51245.5110.0FalseNoneNoneFalseNoneFalse2455.10
3379851119022NoneP-20 I-13.23 .2of Vol 2Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 20 mm nominal bore, 120 mm long, weighing not less than 198 g ---- etc., complete with all leadNos300.2300.21.0FalseNoneNoneFalseNoneFalse300.20
3379852119022NoneP-119 I-13.15 of Vol 2Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 ---- etc., complete with all leadNos881.17881.171.0FalseNoneNoneFalseNoneFalse881.170
3379853119022NoneP-119 I-13.16 of Vol 2Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all leadNos753.55753.5510.0FalseNoneNoneFalseNoneFalse7535.50
3379854119022NoneP-123 I-13.34 of Vol 2Providing and placing on terrace(at all floor levels), polyethylene water storage tank,IS:120701 marked,with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank ---- etc., complete with all leadl10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3379855119022NoneP-123 I-13.39 of Vol 2Providing and fixing square mouth S.W.gully trap class SP-1 complete with C.I.grating,brick masonry camber 150X 100 mm size P type with non modular bcommon burnt clay bricks of designation 3.5 & with water tight.C.I cover with frame of 300X300 mm size (inside)the weight of the cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design ---- etc., complete with all leadEach3136.953136.952.0FalseNoneNoneFalseNoneFalse6273.90
17194745960000NoneNoneBuildings2 Construction of Block level public health laboratory (BLPHL) at GH Kadur in Chikkamagaluru District. (Electrical Works) (Slice-2)366737.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379856119023None2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Short point upto 3 mts from tapping point to out let via switch ---- etc., complete with all leadPoint326.94326.9422.0FalseNoneNoneFalseNoneFalse7192.680
3379857119023None2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint460.64460.6416.0FalseNoneNoneFalseNoneFalse7370.240
3379858119023None2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3379859119023None3.4.2Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 way ---- etc., complete with all leadEach193.25193.2513.0FalseNoneNoneFalseNoneFalse2512.250
3379860119023None3.4.3Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5 way ---- etc., complete with all leadEach215.13215.1312.0FalseNoneNoneFalseNoneFalse2581.560
3379861119023None3.4.4Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
3379862119023None3.4.5Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 way ---- etc., complete with all leadEach317.22317.2219.0FalseNoneNoneFalseNoneFalse6027.180
3379863119023None3.4.7Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 way ---- etc., complete with all leadEach441.19441.197.0FalseNoneNoneFalseNoneFalse3088.330
3379864119023None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module ---- etc., complete with all leadEach195.68195.6813.0FalseNoneNoneFalseNoneFalse2543.840
3379865119023None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module ---- etc., complete with all leadEach212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
3379866119023None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
3379867119023None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module ---- etc., complete with all leadEach345.17345.1719.0FalseNoneNoneFalseNoneFalse6558.230
3379868119023None3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 16 module ---- etc., complete with all leadEach482.51482.517.0FalseNoneNoneFalseNoneFalse3377.570
3379869119023None3.6.1Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch ---- etc., complete with all leadEach123.97123.9784.0FalseNoneNoneFalseNoneFalse10413.480
3379870119023None3.6.3Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets ---- etc., complete with all leadEach207.83207.8316.0FalseNoneNoneFalseNoneFalse3325.280
3379871119023None3.6.4Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's ---- etc., complete with all leadEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3379872119023None3.6.7Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 129316 amps one way switch ---- etc., complete with all leadEach218.77218.7734.0FalseNoneNoneFalseNoneFalse7438.180
3379873119023None3.6.10Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets ---- etc., complete with all leadEach286.83286.8334.0FalseNoneNoneFalseNoneFalse9752.220
3379874119023None3.6.9Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch ---- etc., complete with all leadEach396.22396.223.0FalseNoneNoneFalseNoneFalse1188.660
3379875119023NoneI-1.13Supply and fixing one metal Fan box with round hook ---- etc., complete with all leadEach142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3379876119023None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr80.2280.22130.0FalseNoneNoneFalseNoneFalse10428.60
3379877119023None1.3.1Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 19/20 mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.65250.0FalseNoneNoneFalseNoneFalse20662.50
3379878119023None1.3.2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 25 mm dia ---- etc., complete with all leadMtr96.0296.02220.0FalseNoneNoneFalseNoneFalse21124.40
3379879119023None2.3.2Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 1.5 Sq.mm ---- etc., complete with all leadMtr31.631.6650.0FalseNoneNoneFalseNoneFalse20540.00
3379880119023None2.3.3Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 2.5 sq.mm ---- etc., complete with all leadMtr51.0551.05450.0FalseNoneNoneFalseNoneFalse22972.50
3379881119023None2.3.4Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 4 sq.mm ---- etc., complete with all leadMtr76.5776.57100.0FalseNoneNoneFalseNoneFalse7657.00
3379882119023None2.3.5Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 6 sq.mm ---- etc., complete with all leadMtr111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
3379883119023None2.3.6Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.10 sq.mm ---- etc., complete with all leadMtr202.97202.9760.0FalseNoneNoneFalseNoneFalse12178.20
3379884119023None5.19.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.12 Way SP & N ---- etc., complete with all leadEach2830.672830.672.0FalseNoneNoneFalseNoneFalse5661.340
3379885119023None5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps SP ---- etc., complete with all leadEach504.39504.3918.0FalseNoneNoneFalseNoneFalse9079.020
3379886119023None5.18.4Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.186.0FalseNoneNoneFalseNoneFalse5389.080
3379887119023None5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
3379888119023None32.08 V-61.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) ---- etc., complete with all leadKm218582.4218582.40.1FalseNoneNoneFalseNoneFalse21858.240
3379889119023None21.05 V-6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staff ---- etc., complete with all leadKm25384.8425384.840.1FalseNoneNoneFalseNoneFalse2538.4840
3379890119023None48.05( V-6)2021-22GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia ---- etc., complete with all leadMtr393.79393.795.0FalseNoneNoneFalseNoneFalse1968.950
3379891119023NoneI-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNo4266.054266.052.0FalseNoneNoneFalseNoneFalse8532.10
3379892119023None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip ---- etc., complete with all leadMtr99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
3379893119023NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all leadMtr46.1946.1945.0FalseNoneNoneFalseNoneFalse2078.550
3379894119023None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5242000.0FalseNoneNoneFalseNoneFalse21840.00
3379895119023None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3379896119023None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr370.7370.73.0FalseNoneNoneFalseNoneFalse1112.10
3379897119023None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3379898119023None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.166.0FalseNoneNoneFalseNoneFalse22518.960
3379899119023NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3379900119023NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3379901119023NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
17194745960000NoneNoneBuildings3 Construction of Block level public health laboratory (BLPHL) at GH Sakleshpura in Hassan District. (Civil Works) (Slice-3)4431379.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379902119024NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.46125.4FalseNoneNoneFalseNoneFalse14478.6840
3379903119024NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.97178.2FalseNoneNoneFalseNoneFalse22091.4540
3379904119024NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3160.38FalseNoneNoneFalseNoneFalse51850.8540
3379905119024NoneV-2 P-5 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications ---- etc., complete with all leadSqm143.42143.42200.06FalseNoneNoneFalseNoneFalse28692.60520
3379906119024NoneV-1 P-15 I-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0325.45FalseNoneNoneFalseNoneFalse185251.31350
3379907119024NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Footings ---- etc., complete with all leadCum8252.258252.2548.44FalseNoneNoneFalseNoneFalse399738.990
3379908119024NoneV-1 P-16 I-2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & formwork are included) Plinth Beam ---- etc., complete with all leadCum7875.797875.798.9FalseNoneNoneFalseNoneFalse70094.5310
3379909119024NoneV-1 P-17 I-2.5.2Providing and laying in position Reinforced cement concrete for all S" Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) Columns above plinth ---- etc., complete with all leadCum14138.8714138.877.55FalseNoneNoneFalseNoneFalse106748.46850
3379910119024NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Cills ---- etc., complete with all leadCum8316.988316.980.86FalseNoneNoneFalseNoneFalse7152.60280
3379911119024NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Chajja ---- etc., complete with all leadCum12059.8412059.841.84FalseNoneNoneFalseNoneFalse22190.10560
3379912119024NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) Plinth Beam, Roof Beam, Lintels ---- etc., complete with all leadCum13307.1713307.1723.16FalseNoneNoneFalseNoneFalse308194.05720
3379913119024NoneV-1 P-17 I-2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork & centering included) (Centering & formwork are included) RCC Slab ---- etc., complete with all leadCum12475.4712475.4729.18FalseNoneNoneFalseNoneFalse364034.21460
3379914119024NoneV-1 P-84 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) ---- etc., complete with all leadTonne108726.04108726.047.91FalseNoneNoneFalseNoneFalse860022.97640
3379915119024NoneV-2 P-17 I-6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17231.25FalseNoneNoneFalseNoneFalse368189.31250
3379916119024NoneV-2 P-17 I-6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.853.7FalseNoneNoneFalseNoneFalse72054.660
3379917119024NoneV-2 P-87 I-11.35.2.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg693.99693.9925.2FalseNoneNoneFalseNoneFalse17488.5480
3379918119024NoneV-2 P-88 I-11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadSqm1423.231423.231.2FalseNoneNoneFalseNoneFalse1707.8760
3379919119024NoneV-2 P-88 I-11.36.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both the sids including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1194.741194.741.2FalseNoneNoneFalseNoneFalse1433.6880
3379920119024NoneV-2 P-111 I-12.86Providing & fixing of 2 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6551.016551.0136.45FalseNoneNoneFalseNoneFalse238784.31450
3379921119024NoneV-2 P-110 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.871.62FalseNoneNoneFalseNoneFalse11260.40940
3379922119024NoneV-2 P-85 I-11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc ---- etc., complete with all leadKgs222.42222.42575.91FalseNoneNoneFalseNoneFalse128093.90220
3379923119024NoneV-2 P-82 I-11.26.3Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes in cluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- etc., complete with all leadKgs222.42222.4282.5FalseNoneNoneFalseNoneFalse18349.650
3379924119024NoneV-2 P-100 I-12.13.1Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications. ---- etc., complete with all leadCum120099.75120099.750.2FalseNoneNoneFalseNoneFalse24019.950
3379925119024NoneV-2 P-106 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick Both side commercial. ---- etc., complete with all leadSqm4037.564037.5612.2FalseNoneNoneFalseNoneFalse49258.2320
3379926119024NoneV-2 P-111 I-12.93.2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately).Size 62 x 125mm ---- etc., complete with all leadSqm928.57928.5720.4FalseNoneNoneFalseNoneFalse18942.8280
3379927119024NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all leadSqm4235.674235.677.5FalseNoneNoneFalseNoneFalse31767.5250
3379928119024NoneV-2 P-105 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.854.0FalseNoneNoneFalseNoneFalse4939.40
3379929119024NoneV-2 P-69 I-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9224.0FalseNoneNoneFalseNoneFalse1750.080
3379930119024NoneV-2 P-107 I-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.961353.964.0FalseNoneNoneFalseNoneFalse5415.840
3379931119024NoneV-2 P-107 I-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1278.61278.64.0FalseNoneNoneFalseNoneFalse5114.40
3379932119024NoneV-2 P-107 I-12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. Complete ---- etc., complete with all leadNos1203.251203.254.0FalseNoneNoneFalseNoneFalse4813.00
3379933119024NoneV-2 P-107 I-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos288.05288.058.0FalseNoneNoneFalseNoneFalse2304.40
3379934119024NoneV-2 P-107 I-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete ---- etc., complete with all leadNos158.0158.08.0FalseNoneNoneFalseNoneFalse1264.00
3379935119024NoneV-2 P-107 I-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos66.8566.854.0FalseNoneNoneFalseNoneFalse267.40
3379936119024NoneV-2 P-108 I-12.75Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos334.24334.2412.0FalseNoneNoneFalseNoneFalse4010.880
3379937119024NonePWD SR 18-19 P-117 I-15.37KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment) ---- etc., complete with all leadRmtr34.0334.0324.3FalseNoneNoneFalseNoneFalse826.9290
3379938119024NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ---- etc., complete with all leadSqm1391.631391.63155.7FalseNoneNoneFalseNoneFalse216676.7910
3379939119024NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- etc., complete with all leadSqm1080.491080.498.3FalseNoneNoneFalseNoneFalse8968.0670
3379940119024NoneV-2 P-71 I-10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete ---- etc., complete with all leadSqm1344.231344.2371.4FalseNoneNoneFalseNoneFalse95978.0220
3379941119024NoneV-2 P-64 I-9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications ---- etc., complete with all leadSqm6475.656475.652.7FalseNoneNoneFalseNoneFalse17484.2550
3379942119024NoneV-2 P-63 I-9.28Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications ---- etc., complete with all leadSqm5200.75200.72.5FalseNoneNoneFalseNoneFalse13001.750
3379943119024NoneV-2 P-41 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm339.1339.1144.6FalseNoneNoneFalseNoneFalse49033.860
3379944119024NoneV-2 P-41 I-8.8Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding ,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( Inside) ---- etc., complete with all leadSqm339.1339.1646.6FalseNoneNoneFalseNoneFalse219262.060
3379945119024NoneV-2 P-41 I-8.9Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) finished rough to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( outside) ---- etc., complete with all leadSqm467.93467.93323.1FalseNoneNoneFalseNoneFalse151188.1830
3379946119024NoneV-2 P-47 I-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm64.4264.4229.2FalseNoneNoneFalseNoneFalse1881.0640
3379947119024NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm139.77139.7765.0FalseNoneNoneFalseNoneFalse9085.050
3379948119024NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36791.2FalseNoneNoneFalseNoneFalse122129.6320
3379949119024NoneV-2 P-46 I-8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm211.48211.48323.1FalseNoneNoneFalseNoneFalse68329.1880
3379950119024NoneV-2 P-47 I-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.7735.8FalseNoneNoneFalseNoneFalse2175.5660
3379951119024NoneV-2 P-150 I-15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm747.47747.474.8FalseNoneNoneFalseNoneFalse3587.8560
17194745960000NoneNoneBuildings3 Construction of Block level public health laboratory (BLPHL) at GH Sakleshpura in Hassan District. (Water Supply & Sanitary Works) (Slice-3)192999.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379952119025NoneP-122 I.No.13.32.3 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 25 mm Dia ---- etc., complete with all leadm579.75579.7545.0FalseNoneNoneFalseNoneFalse26088.750
3379953119025NoneP-122 I.No.13.32.4 of Vol.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc 32 mm Dia ---- etc., complete with all leadm676.98676.9835.0FalseNoneNoneFalseNoneFalse23694.30
3379954119025NoneP-119 I.No.13.12 of Vol.2Providing and fixing brass bib cock of approved quality ---- etc., complete with all leadNos771.78771.788.0FalseNoneNoneFalseNoneFalse6174.240
3379955119025NoneP-117 I.No.13.4.1 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore ---- etc., complete with all leadNos667.25667.254.0FalseNoneNoneFalseNoneFalse2669.00
3379956119025NoneP-117 I.No.13.4.2 of Vol.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore ---- etc., complete with all leadNos726.81726.814.0FalseNoneNoneFalseNoneFalse2907.240
3379957119025NoneP.No.131 I.No.14.1.1 of Vol.2Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5936.015936.012.0FalseNoneNoneFalseNoneFalse11872.020
3379958119025NoneP-124 I.No.13.41 of Vol.2Providing and fixing trap of self ceansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors:*100mm inlet and 100mm outlet.* Sand cast iron S&S as per IS:1729. ---- etc., complete with all leadEach1629.851629.858.0FalseNoneNoneFalseNoneFalse13038.80
3379959119025NoneP-125 I.No.13.48 of Vol.2Providing and fixingon wall face unplasticised Rigid PVC rain water pipes confirming to IS:13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for the thermal expansion,(i) Single socketed pipes 100mm diameter ---- etc., complete with all leadRmtr353.68353.6855.0FalseNoneNoneFalseNoneFalse19452.40
3379960119025NoneP.No.6 I.No.1.6.1 of Vol.1Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m ---- etc., complete with all leadCum588.25588.2515.0FalseNoneNoneFalseNoneFalse8823.750
3379961119025NoneP.No.191 I.No.16.10 of Vol.5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNos5148.435148.435.0FalseNoneNoneFalseNoneFalse25742.150
3379962119025NoneP-160, I-1.10 of Vol 1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.468.0FalseNoneNoneFalseNoneFalse1555.680
3379963119025NoneP-123, I-13.36 of Vol 2Cutting holes upto 30X30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks. ---- etc., complete with all leadEach392.57392.5720.0FalseNoneNoneFalseNoneFalse7851.40
3379964119025NoneP-123, I-13.37 of Vol 2Cutting holes upto 15X15cm in RCC floors and roofs for passing drain pipe etc.,and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size)including finishing complete so as to make it leak proof. ---- etc., complete with all leadEach380.42380.4210.0FalseNoneNoneFalseNoneFalse3804.20
3379965119025NoneP-120 I-13.22.2 of Vol 2Providing and fixing PTMT grating of approved quality and colour, Rectangular type with openable circular lid ---- etc., complete with all leadEach245.51245.5110.0FalseNoneNoneFalseNoneFalse2455.10
3379966119025NoneP-20 I-13.23 .2of Vol 2Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 20 mm nominal bore, 120 mm long, weighing not less than 198 g ---- etc., complete with all leadNos300.2300.21.0FalseNoneNoneFalseNoneFalse300.20
3379967119025NoneP-119 I-13.15 of Vol 2Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 ---- etc., complete with all leadNos881.17881.171.0FalseNoneNoneFalseNoneFalse881.170
3379968119025NoneP-119 I-13.16 of Vol 2Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all leadNos753.55753.5510.0FalseNoneNoneFalseNoneFalse7535.50
3379969119025NoneP-123 I-13.34 of Vol 2Providing and placing on terrace(at all floor levels), polyethylene water storage tank,IS:120701 marked,with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank ---- etc., complete with all leadl10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3379970119025NoneP-123 I-13.39 of Vol 2Providing and fixing square mouth S.W.gully trap class SP-1 complete with C.I.grating,brick masonry camber 150X 100 mm size P type with non modular bcommon burnt clay bricks of designation 3.5 & with water tight.C.I cover with frame of 300X300 mm size (inside)the weight of the cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design ---- etc., complete with all leadEach3136.953136.952.0FalseNoneNoneFalseNoneFalse6273.90
17194745960000NoneNoneBuildings3 Construction of Block level public health laboratory (BLPHL) at GH Sakleshpura in Hassan District. (Electrical Works) (Slice-3)366737.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3379971119026None2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Short point upto 3 mts from tapping point to out let via switch ---- etc., complete with all leadPoint326.94326.9422.0FalseNoneNoneFalseNoneFalse7192.680
3379972119026None2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint460.64460.6416.0FalseNoneNoneFalseNoneFalse7370.240
3379973119026None2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3379974119026None3.4.2Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 way ---- etc., complete with all leadEach193.25193.2513.0FalseNoneNoneFalseNoneFalse2512.250
3379975119026None3.4.3Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5 way ---- etc., complete with all leadEach215.13215.1312.0FalseNoneNoneFalseNoneFalse2581.560
3379976119026None3.4.4Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
3379977119026None3.4.5Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 way ---- etc., complete with all leadEach317.22317.2219.0FalseNoneNoneFalseNoneFalse6027.180
3379978119026None3.4.7Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 way ---- etc., complete with all leadEach441.19441.197.0FalseNoneNoneFalseNoneFalse3088.330
3379979119026None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module ---- etc., complete with all leadEach195.68195.6813.0FalseNoneNoneFalseNoneFalse2543.840
3379980119026None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module ---- etc., complete with all leadEach212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
3379981119026None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
3379982119026None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module ---- etc., complete with all leadEach345.17345.1719.0FalseNoneNoneFalseNoneFalse6558.230
3379983119026None3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 16 module ---- etc., complete with all leadEach482.51482.517.0FalseNoneNoneFalseNoneFalse3377.570
3379984119026None3.6.1Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch ---- etc., complete with all leadEach123.97123.9784.0FalseNoneNoneFalseNoneFalse10413.480
3379985119026None3.6.3Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets ---- etc., complete with all leadEach207.83207.8316.0FalseNoneNoneFalseNoneFalse3325.280
3379986119026None3.6.4Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's ---- etc., complete with all leadEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3379987119026None3.6.7Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 129316 amps one way switch ---- etc., complete with all leadEach218.77218.7734.0FalseNoneNoneFalseNoneFalse7438.180
3379988119026None3.6.10Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets ---- etc., complete with all leadEach286.83286.8334.0FalseNoneNoneFalseNoneFalse9752.220
3379989119026None3.6.9Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch ---- etc., complete with all leadEach396.22396.223.0FalseNoneNoneFalseNoneFalse1188.660
3379990119026NoneI-1.13Supply and fixing one metal Fan box with round hook ---- etc., complete with all leadEach142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3379991119026None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr80.2280.22130.0FalseNoneNoneFalseNoneFalse10428.60
3379992119026None1.3.1Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 19/20 mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.65250.0FalseNoneNoneFalseNoneFalse20662.50
3379993119026None1.3.2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary 25 mm dia ---- etc., complete with all leadMtr96.0296.02220.0FalseNoneNoneFalseNoneFalse21124.40
3379994119026None2.3.2Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 1.5 Sq.mm ---- etc., complete with all leadMtr31.631.6650.0FalseNoneNoneFalseNoneFalse20540.00
3379995119026None2.3.3Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 2.5 sq.mm ---- etc., complete with all leadMtr51.0551.05450.0FalseNoneNoneFalseNoneFalse22972.50
3379996119026None2.3.4Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 4 sq.mm ---- etc., complete with all leadMtr76.5776.57100.0FalseNoneNoneFalseNoneFalse7657.00
3379997119026None2.3.5Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 6 sq.mm ---- etc., complete with all leadMtr111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
3379998119026None2.3.6Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.10 sq.mm ---- etc., complete with all leadMtr202.97202.9760.0FalseNoneNoneFalseNoneFalse12178.20
3379999119026None5.19.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.12 Way SP & N ---- etc., complete with all leadEach2830.672830.672.0FalseNoneNoneFalseNoneFalse5661.340
3380000119026None5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps SP ---- etc., complete with all leadEach504.39504.3918.0FalseNoneNoneFalseNoneFalse9079.020
3380001119026None5.18.4Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.186.0FalseNoneNoneFalseNoneFalse5389.080
3380002119026None5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
3380003119026None32.08 V-61.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) ---- etc., complete with all leadKm218582.4218582.40.1FalseNoneNoneFalseNoneFalse21858.240
3380004119026None21.05 V-6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staff ---- etc., complete with all leadKm25384.8425384.840.1FalseNoneNoneFalseNoneFalse2538.4840
3380005119026None48.05( V-6)2021-22GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia ---- etc., complete with all leadMtr393.79393.795.0FalseNoneNoneFalseNoneFalse1968.950
3380006119026NoneI-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNo4266.054266.052.0FalseNoneNoneFalseNoneFalse8532.10
3380007119026None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip ---- etc., complete with all leadMtr99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
3380008119026NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all leadMtr46.1946.1945.0FalseNoneNoneFalseNoneFalse2078.550
3380009119026None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5242000.0FalseNoneNoneFalseNoneFalse21840.00
3380010119026None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3380011119026None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr370.7370.73.0FalseNoneNoneFalseNoneFalse1112.10
3380012119026None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3380013119026None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.166.0FalseNoneNoneFalseNoneFalse22518.960
3380014119026NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3380015119026NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3380016119026NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
17194745970000NoneNoneBuildings4 Construction of Block level public health laboratory (BLPHL) at GH Alur in Hassan District. (Civil Works) (Slice-4)4092404.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3380017119027NoneI-19.7.1 P-163 V-2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum585.82585.828.63FalseNoneNoneFalseNoneFalse5055.62660
3380018119027NoneI-2.5.2 P-17 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & Formwork are inclusive) COLUMNS FF ---- etc., complete with all leadCum14280.2514280.257.82FalseNoneNoneFalseNoneFalse111671.5550
3380019119027NoneI-2.5.2 P-17 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & Formwork are inclusive) RCC BEAMS, LINTELS FF ---- etc., complete with all leadCum13440.2413440.2423.57FalseNoneNoneFalseNoneFalse316786.45680
3380020119027NoneI-2.5.2 P-17 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Centering & Formwork are inclusive) RCC SLAB, STAIRCASE FF ---- etc., complete with all leadCum12600.2312600.2321.36FalseNoneNoneFalseNoneFalse269140.91280
3380021119027NoneI-2.1.4 P-15 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates FF ---- etc., complete with all leadCum7631.77631.720.35FalseNoneNoneFalseNoneFalse155305.0950
3380022119027NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy FF ---- etc., complete with all leadNo.250.42250.4230.0FalseNoneNoneFalseNoneFalse7512.60
3380023119027NoneI-2.11a P-18 V-1Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) FF ---- etc., complete with all leadTonne109813.3109813.36.49FalseNoneNoneFalseNoneFalse712688.3170
3380024119027NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS FF ---- etc., complete with all leadRmtr40.5140.5140.32FalseNoneNoneFalseNoneFalse1633.36320
3380025119027NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. FF ---- etc., complete with all leadRmtr86.1486.1450.0FalseNoneNoneFalseNoneFalse4307.00
3380026119027NoneI-6.32 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FF ---- etc., complete with all leadSqm1608.11608.1307.98FalseNoneNoneFalseNoneFalse495262.6380
3380027119027NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FF ---- etc., complete with all leadSqm1355.221355.2227.09FalseNoneNoneFalseNoneFalse36712.90980
3380028119027NoneI-12.13.1 P-100 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FF ---- etc., complete with all leadCum121300.75121300.750.82FalseNoneNoneFalseNoneFalse99466.6150
3380029119027NoneI-12.51 P-105 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FF ---- etc., complete with all leadNos1247.191247.1912.0FalseNoneNoneFalseNoneFalse14966.280
3380030119027NoneA.RProviding and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. (Locking Arrangements) FF ---- etc., complete with all leadNos2360.02360.012.0FalseNoneNoneFalseNoneFalse28320.00
3380031119027NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FF ---- etc., complete with all leadNos73.6573.6572.0FalseNoneNoneFalseNoneFalse5302.80
3380032119027NoneI-313 (0115) P-XI S.R 2018-19Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. FF ---- etc., complete with all leadRmtr15.615.672.6FalseNoneNoneFalseNoneFalse1132.560
3380033119027NoneI-12.57.6 P-106 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FF ---- etc., complete with all leadSqm4077.934077.9336.0FalseNoneNoneFalseNoneFalse146805.480
3380034119027NoneI-12.90 P-112 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FF ---- etc., complete with all leadSqm8266.358266.3527.0FalseNoneNoneFalseNoneFalse223191.450
3380035119027NoneI-12.85 P-110 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FF ---- etc., complete with all leadSqm7020.387020.381.62FalseNoneNoneFalseNoneFalse11373.01560
3380036119027NoneI-11.34A P-110 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FF ---- etc., complete with all leadKg206.23206.23601.02FalseNoneNoneFalseNoneFalse123948.35460
3380037119027NoneI-12.54 P-105 V-2Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. FF ---- etc., complete with all leadm390.36390.363.15FalseNoneNoneFalseNoneFalse1229.6340
3380038119027NoneI-12.55.2 P-106 V-2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. FF ---- etc., complete with all leadSqm2504.212504.213.15FalseNoneNoneFalseNoneFalse7888.26150
3380039119027NoneI-12.59 P-107 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FF ---- etc., complete with all leadNos1367.51367.512.0FalseNoneNoneFalseNoneFalse16410.00
3380040119027NoneI-11.35.2.1 P-77 V-2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to re- quired shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials,labour,usage charges of machinery complete as per specifications. FF ---- etc., complete with all leadKg655.51655.5128.8FalseNoneNoneFalseNoneFalse18878.6880
3380041119027NoneI-11.36.1 P-77 V-2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. FF ---- etc., complete with all leadSqm1101.121101.121.44FalseNoneNoneFalseNoneFalse1585.61280
3380042119027NoneI-11.37.1 P-77 V-2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FF ---- etc., complete with all leadSqm1212.821212.821.44FalseNoneNoneFalseNoneFalse1746.46080
3380043119027NoneI-8.5.2 P-41 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Inside) FF ---- etc., complete with all leadSqm428.42428.42289.41FalseNoneNoneFalseNoneFalse123989.03220
3380044119027NoneI-8.10 P-43 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm259.01259.01126.96FalseNoneNoneFalseNoneFalse32883.90960
3380045119027NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FF ---- etc., complete with all leadSqm122.76122.76512.65FalseNoneNoneFalseNoneFalse62932.9140
3380046119027NoneI-8.8 P-42 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. . (outside) FF ---- etc., complete with all leadSqm455.42455.42221.68FalseNoneNoneFalseNoneFalse100957.50560
3380047119027NoneI-8.3.1 P-42 V-2Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm434.55434.5518.32FalseNoneNoneFalseNoneFalse7960.9560
3380048119027NoneI-8.16.3 P-43 V-2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm wide FF ---- etc., complete with all leadRmtr54.0154.01294.4FalseNoneNoneFalseNoneFalse15900.5440
3380049119027NoneI-6.12 P-14 V-2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FF ---- etc., complete with all leadSqm1231.241231.247.2FalseNoneNoneFalseNoneFalse8864.9280
3380050119027NoneI-7.18 P-23 V-2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FF ---- etc., complete with all leadCum2475.982475.981.95FalseNoneNoneFalseNoneFalse4828.1610
3380051119027NoneI-15.7 P-134 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm754.95754.9537.55FalseNoneNoneFalseNoneFalse28348.37250
3380052119027NoneI-10.5.2 P-70 S.R 2018-19Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm265.15265.1525.0FalseNoneNoneFalseNoneFalse6628.750
3380053119027NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FF ---- etc., complete with all leadRmtr63.8363.83216.67FalseNoneNoneFalseNoneFalse13830.04610
3380054119027NoneI-9.21.2 P-62 V-2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).). Size of Tile 600x600 mm FF ---- etc., complete with all leadSqm1519.711519.71142.52FalseNoneNoneFalseNoneFalse216589.06920
3380055119027NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm362.13362.13217.95FalseNoneNoneFalseNoneFalse78926.23350
3380056119027NoneI-9.9 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. FF ---- etc., complete with all leadSqm1320.851320.856.5FalseNoneNoneFalseNoneFalse8585.5250
3380057119027NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FF ---- etc., complete with all leadSqm1778.731778.73217.95FalseNoneNoneFalseNoneFalse387674.20350
3380058119027NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm155.9155.9512.65FalseNoneNoneFalseNoneFalse79922.1350
3380059119027NoneI-8.30 P-46 V-2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm213.59213.59221.68FalseNoneNoneFalseNoneFalse47348.63120
3380060119027NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm141.17141.1728.62FalseNoneNoneFalseNoneFalse4040.28540
3380061119027NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF ---- etc., complete with all leadSqm65.0665.0679.49FalseNoneNoneFalseNoneFalse5171.61940
3380062119027NoneI-8.38 P-48 V-2Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm49.149.179.49FalseNoneNoneFalseNoneFalse3902.9590
3380063119027NoneI-10.1.2 P-65 V-2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GF ---- etc., complete with all leadSqm4832.884832.887.2FalseNoneNoneFalseNoneFalse34796.7360
17194745970000NoneNoneBuildings4 Construction of Block level public health laboratory (BLPHL) at GH Alur in Hassan District. (Water Supply & Sanitary Works) (Slice-4)273210.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3380064119028NoneV-2 P-122 I- 13.31.2Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes JOinting of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 20 mm Dia ---- etc., complete with all leadRmtr294.13294.1360.0FalseNoneNoneFalseNoneFalse17647.80
3380065119028NoneV-2 P-122 I- 13.31.3Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes JOinting of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 25 mm Dia ---- etc., complete with all leadRmtr386.5386.540.0FalseNoneNoneFalseNoneFalse15460.00
3380066119028NoneV-2 P-117 I- 13.2.1Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. ---- etc., complete with all leadNos347.6347.64.0FalseNoneNoneFalseNoneFalse1390.40
3380067119028NoneV-2 P-117 I- 13.4.1Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. 25 mm Dia ---- etc., complete with all leadNos667.25667.254.0FalseNoneNoneFalseNoneFalse2669.00
3380068119028NoneV-2 P-117 I- 13.4.2Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. 32 mm Dia ---- etc., complete with all leadNos726.81726.814.0FalseNoneNoneFalseNoneFalse2907.240
3380069119028NoneV-2 P-132 I-14.7.1KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- etc., complete with all leadNos3745.863745.863.0FalseNoneNoneFalseNoneFalse11237.580
3380070119028NoneV-2 P-137 I-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadNos602.84602.843.0FalseNoneNoneFalseNoneFalse1808.520
3380071119028NoneV-2 P-136 I-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm ---- etc., complete with all leadNos1237.281237.283.0FalseNoneNoneFalseNoneFalse3711.840
3380072119028NoneV-2 P-138 I-14.47Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc in cluding making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge ---- etc., complete with all leadNos17273.2617273.262.0FalseNoneNoneFalseNoneFalse34546.520
3380073119028NoneP-90 I-12.113.1 S.R 2018-19 Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). For 10cms x 7.5cms ---- etc., complete with all leadNos303.85303.857.0FalseNoneNoneFalseNoneFalse2126.950
3380074119028NoneV-2 P-125 I-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadRmtr353.68353.6880.0FalseNoneNoneFalseNoneFalse28294.40
3380075119028NoneV-2 P-128 I-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75MM DIA ---- etc., complete with all leadRmtr351.25351.2530.0FalseNoneNoneFalseNoneFalse10537.50
3380076119028NoneV-2 P-128 I-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110MM DIA ---- etc., complete with all leadRmtr467.93467.9340.0FalseNoneNoneFalseNoneFalse18717.20
3380077119028NoneV-2 P-126 I-13.53KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. ---- etc., complete with all leadNos6857.296857.292.0FalseNoneNoneFalseNoneFalse13714.580
3380078119028NoneV-2 P-126 I-13.54KSRB 12-8.2 : Constructing brick masonry inspection chamber 500x700mm, and 450mm depth, ( clear inside dimension ) for pipeline with one or two inlets, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 500x700mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement concrete M15 with 20mm and downsize granite metal , foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. ---- etc., complete with all leadNos7630.287630.282.0FalseNoneNoneFalseNoneFalse15260.560
3380079119028NoneP-6 V-1 I-1.6.1KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 Add Extra Rate of 50 percent for EWE for Width lesser than 600mm ---- etc., complete with all leadCum588.25588.2522.0FalseNoneNoneFalseNoneFalse12941.50
3380080119028NoneV-1 I-1.10 P-7KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications allow 60% of rate considered under item KSRB 2.3 ---- etc., complete with all leadCum194.46194.4622.0FalseNoneNoneFalseNoneFalse4278.120
3380081119028NoneI-270 I.No.37.35 S.R 2018-19Making Wall bores in Brick masonry upto 45 cm thick width for soil / water pipes including redoing with C.M ( 1:4 ) with all lead and lift as directed by Engineer-in-charge. ---- etc., complete with all leadNos153.14153.1415.0FalseNoneNoneFalseNoneFalse2297.10
3380082119028NoneP.No.273 I.No.37.28.2 S.R 2018-19Drilling holes of2.50 cms dia (roof/chaJja/stone). including cost of materials, labour, HOM complete as per specifications. in slabs upto 10 cms thick ---- etc., complete with all leadNos190.82190.826.0FalseNoneNoneFalseNoneFalse1144.920
3380083119028NoneP.No.90 I.No.12.111 S.R 2018-19Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100mm dia. ---- etc., complete with all leadNos182.31182.317.0FalseNoneNoneFalseNoneFalse1276.170
3380084119028NoneV-2 P-117 I-13.5.1KSRB13-6.4-1 : Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. ---- etc., complete with all leadNos359.76359.762.0FalseNoneNoneFalseNoneFalse719.520
3380085119028NoneV-2 P-123 I-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank ---- etc., complete with all leadEach10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3380086119028NoneA.RProviding & fixing approved quality aquaguard water purifier, etc complete as per specification ---- etc., complete with all leadEach25960.025960.01.0FalseNoneNoneFalseNoneFalse25960.00
3380087119028NoneA.RProviding & fixing 1 HP Mono block pump of approved make with all accessories etc.., complete including cost of materials, labour as per specifications.& as per the direction of the Engineer - in - charge ---- etc., complete with all leadEach8260.08260.01.0FalseNoneNoneFalseNoneFalse8260.00
3380088119028NonePage no 126 ,item no 14.11.2 SR 2021-22 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm ---- etc., complete with all leadEach6176.666176.664.0FalseNoneNoneFalseNoneFalse24706.640
3380089119028NonePage no 128 ,item no 14.28.1.2 SR 2021-22 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 40 mm dia ---- etc., complete with all leadEach106.96106.964.0FalseNoneNoneFalseNoneFalse427.840
3380090119028NonePage no 128 ,item no 14.29 SR 2021-22 V-2Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all leadEach57.1257.124.0FalseNoneNoneFalseNoneFalse228.480
17194745970000NoneNoneBuildings4 Construction of Block level public health laboratory (BLPHL) at GH Alur in Hassan District. (Electrical Works) (Slice-4)517789.34
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3380091119029None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint460.64460.649.0FalseNoneNoneFalseNoneFalse4145.760
3380092119029None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3380093119029None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadPoint822.83822.8320.0FalseNoneNoneFalseNoneFalse16456.60
3380094119029None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete with all leadEach167.73167.7320.0FalseNoneNoneFalseNoneFalse3354.60
3380095119029None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
3380096119029None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach215.13215.135.0FalseNoneNoneFalseNoneFalse1075.650
3380097119029None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all leadEach267.39267.3910.0FalseNoneNoneFalseNoneFalse2673.90
3380098119029None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach317.22317.2212.0FalseNoneNoneFalseNoneFalse3806.640
3380099119029None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.5120.0FalseNoneNoneFalseNoneFalse3330.20
3380100119029None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all leadEach212.7212.75.0FalseNoneNoneFalseNoneFalse1063.50
3380101119029None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach284.4284.45.0FalseNoneNoneFalseNoneFalse1422.00
3380102119029None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
3380103119029None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach418.1418.112.0FalseNoneNoneFalseNoneFalse5017.20
3380104119029None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 6Amps one way Switch ---- etc., complete with all leadEach123.97123.9784.0FalseNoneNoneFalseNoneFalse10413.480
3380105119029None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 6Amps 3way socket ---- etc., complete with all leadEach207.83207.8340.0FalseNoneNoneFalseNoneFalse8313.20
3380106119029None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) Stepped Fan Regulator. ---- etc., complete with all leadEach433.9433.99.0FalseNoneNoneFalseNoneFalse3905.10
3380107119029None3.6.7Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 16Amps one way switch ---- etc., complete with all leadEach215.13215.134.0FalseNoneNoneFalseNoneFalse860.520
3380108119029None3.6.10Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 32Amps DP switch ---- etc., complete with all leadEach286.83286.836.0FalseNoneNoneFalseNoneFalse1720.980
3380109119029None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) 6/16Amps universal socket ---- etc., complete with all leadEach189.6189.610.0FalseNoneNoneFalseNoneFalse1896.00
3380110119029None3.6.12Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) RJ45/ I.O. outlet ---- etc., complete with all leadEach409.59409.594.0FalseNoneNoneFalseNoneFalse1638.360
3380111119029None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) Telephone socket ---- etc., complete with all leadEach189.6189.64.0FalseNoneNoneFalseNoneFalse758.40
3380112119029NoneI-1.12Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo194.46194.469.0FalseNoneNoneFalseNoneFalse1750.140
3380113119029None1.1.1Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 19/20mm dia 2mm thick ---- etc., complete with all leadm83.8683.86400.0FalseNoneNoneFalseNoneFalse33544.00
3380114119029None1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 25mm dia 2mm thick ---- etc., complete with all leadm98.4598.45250.0FalseNoneNoneFalseNoneFalse24612.50
3380115119029None1.1.3Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1.1) 32mm dia 2.5mm thick ---- etc., complete with all leadm128.83128.83100.0FalseNoneNoneFalseNoneFalse12883.00
3380116119029None1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 19/20mm dia 2mm thick ---- etc., complete with all leadm82.6582.65180.0FalseNoneNoneFalseNoneFalse14877.00
3380117119029None1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02220.0FalseNoneNoneFalseNoneFalse21124.40
3380118119029None1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3240.0FalseNoneNoneFalseNoneFalse4812.80
3380119119029None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm31.631.6200.0FalseNoneNoneFalseNoneFalse6320.00
3380120119029None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm51.0551.05500.0FalseNoneNoneFalseNoneFalse25525.00
3380121119029None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm76.5776.57300.0FalseNoneNoneFalseNoneFalse22971.00
3380122119029None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3380123119029NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all leadm46.1946.19100.0FalseNoneNoneFalseNoneFalse4619.00
3380124119029None8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm25.5225.52100.0FalseNoneNoneFalseNoneFalse2552.00
3380125119029None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6321.0FalseNoneNoneFalseNoneFalse17611.230
3380126119029None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete with all leadEach1609.191609.196.0FalseNoneNoneFalseNoneFalse9655.140
3380127119029None11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3380128119029NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.384.0FalseNoneNoneFalseNoneFalse7253.520
3380129119029None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.759.0FalseNoneNoneFalseNoneFalse32640.750
3380130119029None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2827.0FalseNoneNoneFalseNoneFalse4003.560
3380131119029NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.839.0FalseNoneNoneFalseNoneFalse1870.470
3380132119029NoneI-13.11Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach382.85382.854.0FalseNoneNoneFalseNoneFalse1531.40
3380133119029None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 4 Way TPN DB ---- etc., complete with all leadEach4907.794907.792.0FalseNoneNoneFalseNoneFalse9815.580
3380134119029None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach504.39504.3924.0FalseNoneNoneFalseNoneFalse12105.360
3380135119029None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all leadEach3699.683699.682.0FalseNoneNoneFalseNoneFalse7399.360
3380136119029None5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 Amps 4 pole ---- etc., complete with all leadEach5541.015541.012.0FalseNoneNoneFalseNoneFalse11082.020
3380137119029None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5260000.0FalseNoneNoneFalseNoneFalse31200.00
3380138119029None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3380139119029None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm370.7370.76.0FalseNoneNoneFalseNoneFalse2224.20
3380140119029None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.846.0FalseNoneNoneFalseNoneFalse5513.040
3380141119029None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR POLE 100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3380142119029None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all leadEach3699.683699.684.0FalseNoneNoneFalseNoneFalse14798.720
3380143119029NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3380144119029NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
3380145119029NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3380146119029NoneI-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 35 sqmm ---- etc., complete with all leadKm187246.95187246.950.05FalseNoneNoneFalseNoneFalse9362.34750
3380147119029NoneI-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm ---- etc., complete with all leadKm37846.3437846.340.05FalseNoneNoneFalseNoneFalse1892.3170
3380148119029NoneEle 6.11.4 S.R 2019-2020Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 45mm dia ---- etc., complete with all leadEach235.79235.794.0FalseNoneNoneFalseNoneFalse943.160
3380149119029NoneEle 6.9.2 S.R 2019-2020Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 50mm ---- etc., complete with all leadm461.85461.8510.0FalseNoneNoneFalseNoneFalse4618.50
3380150119029NoneEle 6.17.8 S.R 2019-2020Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all leadEach38.8938.898.0FalseNoneNoneFalseNoneFalse311.120
3380151119029NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3380152119029None12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194745990000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194745990000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194745990000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194745990000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194745990000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194808750000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17194808870000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17194808970000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194809090000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17194810100000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17194810220000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17194810360000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17194810500000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17194810620000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17194810750000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17194810870000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17194811000000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17194811120000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17194811240000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17194811370000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17194811650000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17194811860000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17194866670000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17194866820000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.99.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.8.10 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.4.50 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 730.00 Cum,2)RCC and PCC 410.00 Cum 3)Steel Reinforcement for RCC work 25.00 Tonnes 4)Cement Concrete Block Masonry/Solid Block Masonry, Load bearing wall 710.00 Sqm 5)Flooring /Dadooing(Vitrified/Granite/Ceramic/Cement concrete/ cladding/ dadooing) 880.00 Sqm, 6) Plastering 3900.00 Sqm,7)Painting 3000.00 Sqm 8) M.S.Grill 1900.00Kg, 9)WPC 42.00 Sqm Note -The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneKPWD Class-III & Above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PWD Registration Certificate issued by Chief Engineer, PWD
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 6 months. Note. The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing commitments and Bids submitted for the works certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years - 2 Two. 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years - 1 One.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates to be furnished
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer-1 No. 2). Centering sheets-500 sqmtr.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.398.00 Lakhs. Note: a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turn over and balance sheet, Proft and loss Certified balance sheet audited CA Certificate by Chartered Accountant
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.59.70 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by a Scheduled/Nationalised Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate & profit & loss Certified balance sheet issued by Chartered AccountantTrueTechnical Bid
KPWD class-III and above Registration Certificate issued by Competant AuthorityTrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their nameTrueTechnical Bid
Work done certificate issued by not below the rank of Executive Engineer.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719491639000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road,
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone