createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719484759771
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2500.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-07-2024 16:00:00
tenderQueryClose03-07-2024 12:30:00
technicalBidOpen09-07-2024 16:30:00
publishedDate27-06-2024 18:01:31
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1719484759797
version12
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT502
titleCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) IN THE PREMISES OF TLH AT 1) GH RANEBENNUR IN HAVERI DISTRICT AND 2) TLH MUNDAGOD IN UTTARA KANNADA DISTRICT
descriptionCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) IN THE PREMISES OF TLH AT 1) GH RANEBENNUR IN HAVERI DISTRICT AND 2) TLH MUNDAGOD IN UTTARA KANNADA DISTRICT
categoryWORKS
categoryTextWorks
ecv9960335.65
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount10000000.0
groupOverheadTotal0.0
fileNumberHFWD/AEE/SDHVR/BPHU/RANEBENNUR/2024/25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194847600000NoneNoneBuildingsCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH RANEBENNUR - CIVIL & WATER SUPPLY WORK (SLICE-01)4420807.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385069119216None2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle - GF ---- etc., complete with all leadha477.65477.651.75FalseNoneNoneFalseNoneFalse835.88750
3385070119216None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth - GF ---- etc., complete with all leadCum115.46115.4634.99FalseNoneNoneFalseNoneFalse4039.94540
3385071119216None1.14.1 - V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m - GF ---- etc., complete with all leadCum123.97123.9767.88FalseNoneNoneFalseNoneFalse8415.08360
3385072119216None1.15.1-V-1 Earth work excavation for Foundation by mechanical means for the work In ordinary/soft rock without blasting upto 1.5 m depth, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - GF ---- etc., complete with all leadCum441.19441.1914.0FalseNoneNoneFalseNoneFalse6176.660
3385073119216None1.1 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) - GF ---- etc., complete with all leadCum164.08164.08114.0FalseNoneNoneFalseNoneFalse18705.120
3385074119216None4.1-V-2 Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications - GF ---- etc., complete with all leadSqm143.42143.42102.18FalseNoneNoneFalseNoneFalse14654.65560
3385075119216None1.9-V-1 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m - GF ---- etc., complete with all leadCum323.3323.337.49FalseNoneNoneFalseNoneFalse12120.5170
3385076119216None1.8 - V-1 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work - GF ---- etc., complete with all leadCum576.1576.117.21FalseNoneNoneFalseNoneFalse9914.6810
3385077119216None2.1.3 - V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates - GF ---- etc., complete with all leadCum7279.037279.0329.44FalseNoneNoneFalseNoneFalse214294.64320
3385078119216None2.2.2.1 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - FOOTINGS ---- etc., complete with all leadCum8252.528252.526.91FalseNoneNoneFalseNoneFalse57024.91320
3385079119216None2.2.2.1 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - PEDESTALS ---- etc., complete with all leadCum8405.348405.341.2FalseNoneNoneFalseNoneFalse10086.4080
3385080119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - COLUMNS ---- etc., complete with all leadCum13698.7713698.774.42FalseNoneNoneFalseNoneFalse60548.56340
3385081119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - PLINTH BEAM, GF - RCC SLAB ---- etc., complete with all leadCum12087.1512087.1518.92FalseNoneNoneFalseNoneFalse228688.8780
3385082119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - LINTELS, GF - RCC BEAMS ---- etc., complete with all leadCum12892.9612892.9611.21FalseNoneNoneFalseNoneFalse144530.08160
3385083119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - GF - RCC STAIRCASE ---- etc., complete with all leadCum11684.2511684.251.81FalseNoneNoneFalseNoneFalse21148.49250
3385084119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - FF - COLUMNS ---- etc., complete with all leadCum13835.7613835.763.78FalseNoneNoneFalseNoneFalse52299.17280
3385085119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - FF - RCC BEAMS ---- etc., complete with all leadCum13021.8913021.898.36FalseNoneNoneFalseNoneFalse108863.00040
3385086119216NoneV-1 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - FF - RCC SLAB ---- etc., complete with all leadCum12208.0212208.028.13FalseNoneNoneFalseNoneFalse99251.20260
3385087119216None15.4 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy - GF ---- etc., complete with all leadNo247.94247.948.0FalseNoneNoneFalseNoneFalse1983.520
3385088119216None15.4 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy - FF ---- etc., complete with all leadNo250.42250.425.0FalseNoneNoneFalseNoneFalse1252.10
3385089119216None2.11a V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - GF ---- etc., complete with all leadTonne108726.04108726.043.73FalseNoneNoneFalseNoneFalse405548.12920
3385090119216None2.11a V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - FF ---- etc., complete with all leadTonne109813.3109813.31.66FalseNoneNoneFalseNoneFalse182290.0780
3385091119216None4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS - GF ---- etc., complete with all leadRmtr38.9438.9430.6FalseNoneNoneFalseNoneFalse1191.5640
3385092119216None4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS - FF ---- etc., complete with all leadRmtr38.9438.9425.52FalseNoneNoneFalseNoneFalse993.74880
3385093119216NoneData RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge - GF ---- etc., complete with all leadRmtr86.1486.1450.1FalseNoneNoneFalseNoneFalse4315.6140
3385094119216NoneData Rate Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge - FF ---- etc., complete with all leadRmtr86.1486.1439.64FalseNoneNoneFalseNoneFalse3414.58960
3385095119216None6.3 - V-2Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - GF ---- etc., complete with all leadCum10785.4610785.4625.59FalseNoneNoneFalseNoneFalse275999.92140
3385096119216None6.3 - V-2Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - FF ---- etc., complete with all leadCum10893.3110893.3125.32FalseNoneNoneFalseNoneFalse275818.60920
3385097119216None6.15 V-2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - GF ---- etc., complete with all leadSqm1255.511255.5142.65FalseNoneNoneFalseNoneFalse53547.50150
3385098119216None6.15 V-2Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - FF ---- etc., complete with all leadSqm1268.061268.0620.18FalseNoneNoneFalseNoneFalse25589.45080
3385099119216None12.13.1 - V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - GF ---- etc., complete with all leadCum120099.75120099.750.8485FalseNoneNoneFalseNoneFalse101904.6378750
3385100119216None12.13.1 - V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - FF ---- etc., complete with all leadCum121300.74121300.740.024FalseNoneNoneFalseNoneFalse2911.217760
3385101119216None12.51 - V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - GF ---- etc., complete with all leadNos1234.851234.8511.0FalseNoneNoneFalseNoneFalse13583.350
3385102119216None12.51 - V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - FF ---- etc., complete with all leadNos1247.191247.192.0FalseNoneNoneFalseNoneFalse2494.380
3385103119216None12.60 - V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete - GF ---- etc., complete with all leadNos1278.61278.611.0FalseNoneNoneFalseNoneFalse14064.60
3385104119216None12.60 - V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete - FF ---- etc., complete with all leadNos1291.391291.392.0FalseNoneNoneFalseNoneFalse2582.780
3385105119216None12.61 - V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete - GF ---- etc., complete with all leadNos1203.251203.2511.0FalseNoneNoneFalseNoneFalse13235.750
3385106119216None12.63 - V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - GF ---- etc., complete with all leadNos158.0158.02.0FalseNoneNoneFalseNoneFalse316.00
3385107119216None12.64 - V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - GF ---- etc., complete with all leadNos66.8566.8511.0FalseNoneNoneFalseNoneFalse735.350
3385108119216None12.64 - V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - FF ---- etc., complete with all leadNos67.5267.522.0FalseNoneNoneFalseNoneFalse135.040
3385109119216None12.75.1 - V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - GF ---- etc., complete with all leadNos334.24334.2436.0FalseNoneNoneFalseNoneFalse12032.640
3385110119216None12.75.1 - V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FF ---- etc., complete with all leadNos337.57337.574.0FalseNoneNoneFalseNoneFalse1350.280
3385111119216None12.57.3 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - GF ---- etc., complete with all leadSqm3652.283652.2821.84FalseNoneNoneFalseNoneFalse79765.79520
3385112119216None12.57.3 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FF ---- etc., complete with all leadSqm3688.83688.85.04FalseNoneNoneFalseNoneFalse18591.5520
3385113119216None12.84 V-2Providing fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, - GF ---- etc., complete with all leadSqm6104.956104.9511.52FalseNoneNoneFalseNoneFalse70329.0240
3385114119216None12.84 V-2Providing fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, - FF ---- etc., complete with all leadSqm6166.016166.0111.52FalseNoneNoneFalseNoneFalse71032.43520
3385115119216None12.85 - V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) - GF ---- etc., complete with all leadSqm6950.876950.871.62FalseNoneNoneFalseNoneFalse11260.40940
3385116119216None12.85 - V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) - FF ---- etc., complete with all leadSqm7020.397020.391.08FalseNoneNoneFalseNoneFalse7582.02120
3385117119216None11.34B V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc - GF ---- etc., complete with all leadKg204.19204.19411.62FalseNoneNoneFalseNoneFalse84048.68780
3385118119216None11.34B V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc - FF ---- etc., complete with all leadKg206.23206.23265.2FalseNoneNoneFalseNoneFalse54692.1960
3385119119216None12.96 V-2Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame - GF ---- etc., complete with all leadm781.5781.59.9FalseNoneNoneFalseNoneFalse7736.850
3385120119216None12.96 V-2Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame - FF ---- etc., complete with all leadm789.31789.319.9FalseNoneNoneFalseNoneFalse7814.1690
3385121119216None12.97.1 V-2Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames - GF ---- etc., complete with all leadSqm3894.143894.143.15FalseNoneNoneFalseNoneFalse12266.5410
3385122119216None12.97.1 V-2Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames - FF ---- etc., complete with all leadSqm3933.083933.083.15FalseNoneNoneFalseNoneFalse12389.2020
3385123119216None12.59 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete - GF ---- etc., complete with all leadNos1353.961353.969.0FalseNoneNoneFalseNoneFalse12185.640
3385124119216None12.59 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete - FF ---- etc., complete with all leadNos1367.491367.492.0FalseNoneNoneFalseNoneFalse2734.980
3385125119216None8.1 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Inside) - GF ---- etc., complete with all leadSqm256.45256.45102.18FalseNoneNoneFalseNoneFalse26204.0610
3385126119216None8.1 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Inside) - FF ---- etc., complete with all leadSqm259.01259.0166.29FalseNoneNoneFalseNoneFalse17169.77290
3385127119216None8.7 V-2Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm444.84444.84243.8FalseNoneNoneFalseNoneFalse108451.9920
3385128119216None8.7 V-2Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm449.29449.29151.2FalseNoneNoneFalseNoneFalse67932.6480
3385129119216None8.51 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - GF ---- etc., complete with all leadSqm121.54121.54351.64FalseNoneNoneFalseNoneFalse42738.32560
3385130119216None8.51 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - FF ---- etc., complete with all leadSqm122.76122.76234.94FalseNoneNoneFalseNoneFalse28841.23440
3385131119216None8.8 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Outside) - GF ---- etc., complete with all leadSqm450.91450.91119.67FalseNoneNoneFalseNoneFalse53960.39970
3385132119216None8.8 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Outside) - FF ---- etc., complete with all leadSqm455.42455.42162.34FalseNoneNoneFalseNoneFalse73932.88280
3385133119216None8.16.2 V-2KSRB 15.8.3 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) - GF ---- etc., complete with all leadRmtr46.1946.19255.6FalseNoneNoneFalseNoneFalse11806.1640
3385134119216None8.16.2 V-2KSRB 15.8.3 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) - FF ---- etc., complete with all leadRmtr46.6546.65188.39FalseNoneNoneFalseNoneFalse8788.39350
3385135119216None8.79 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove - GF ---- etc., complete with all leadRmtr63.263.2290.0FalseNoneNoneFalseNoneFalse18328.00
3385136119216None8.79 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove - FF ---- etc., complete with all leadRmtr63.8463.84279.48FalseNoneNoneFalseNoneFalse17842.00320
3385137119216None9.17.2 V-2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm - GF ---- etc., complete with all leadSqm1428.11428.176.16FalseNoneNoneFalseNoneFalse108764.0960
3385138119216None9.17.2 V-2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm - FF ---- etc., complete with all leadSqm1442.371442.3753.4FalseNoneNoneFalseNoneFalse77022.5580
3385139119216None8.2.1 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm358.54358.54133.03FalseNoneNoneFalseNoneFalse47696.57620
3385140119216None8.2.1 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm362.13362.13151.2FalseNoneNoneFalseNoneFalse54754.0560
3385141119216None9.23 V-2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent - GF ---- etc., complete with all leadSqm2997.182997.1815.26FalseNoneNoneFalseNoneFalse45736.96680
3385142119216None15.7 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) - GF ---- etc., complete with all leadSqm747.47747.473.12FalseNoneNoneFalseNoneFalse2332.10640
3385143119216None15.7 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) - FF ---- etc., complete with all leadSqm754.94754.943.12FalseNoneNoneFalseNoneFalse2355.41280
3385144119216None9.11 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete - GF ---- etc., complete with all leadSqm1080.491080.493.12FalseNoneNoneFalseNoneFalse3371.12880
3385145119216None9.11 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete - FF ---- etc., complete with all leadSqm1091.31091.38.15FalseNoneNoneFalseNoneFalse8894.0950
3385146119216None9.39 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - GF ---- etc., complete with all leadSqm1761.111761.1136.29FalseNoneNoneFalseNoneFalse63910.68190
3385147119216None9.39 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - FF ---- etc., complete with all leadSqm1778.721778.7211.45FalseNoneNoneFalseNoneFalse20366.3440
3385148119216None11.26.1 V-2Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - GF ---- etc., complete with all leadKg167.73167.73170.4FalseNoneNoneFalseNoneFalse28581.1920
3385149119216None8.39 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm154.36154.36351.64FalseNoneNoneFalseNoneFalse54279.15040
3385150119216None8.39 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm155.9155.9234.94FalseNoneNoneFalseNoneFalse36627.1460
3385151119216None8.32 V-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm189.6189.6119.67FalseNoneNoneFalseNoneFalse22689.4320
3385152119216None8.32 V-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm191.5191.5162.34FalseNoneNoneFalseNoneFalse31088.110
3385153119216None8.34.3 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm60.7760.7713.14FalseNoneNoneFalseNoneFalse798.51780
3385154119216None8.34.3 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm61.3861.3812.6FalseNoneNoneFalseNoneFalse773.3880
3385155119216None8.4 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm139.77139.7769.34FalseNoneNoneFalseNoneFalse9691.65180
3385156119216None8.4 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge -FF ---- etc., complete with all leadSqm141.16141.1617.64FalseNoneNoneFalseNoneFalse2490.06240
3385157119216None8.34.1 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - GF ---- etc., complete with all leadSqm64.4264.4256.2FalseNoneNoneFalseNoneFalse3620.4040
3385158119216None8.34.1 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - FF ---- etc., complete with all leadSqm65.0765.075.04FalseNoneNoneFalseNoneFalse327.95280
3385159119216None2.1.4 - V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates - FF ---- etc., complete with all leadCum7631.837631.831.72FalseNoneNoneFalseNoneFalse13126.74760
3385160119216None15.1 - V-2Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge - FF ---- etc., complete with all leadSqm1002.921002.9286.82FalseNoneNoneFalseNoneFalse87073.51440
3385161119216None14.28.2.2 - V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines - GF ---- etc., complete with all leadMtr111.82111.824.0FalseNoneNoneFalseNoneFalse447.280
3385162119216None14.28.2.2 - V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines - FF ---- etc., complete with all leadMtr112.94112.944.0FalseNoneNoneFalseNoneFalse451.760
3385163119216None16.7.4 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - GF - 50mm nominal bore pipes, From Sink & Urinal lines ---- etc., complete with all leadm168.94168.9410.0FalseNoneNoneFalseNoneFalse1689.40
3385164119216None16.7.4 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - FF - 50mm nominal bore pipes, From Sink & Urinal lines ---- etc., complete with all leadm170.63170.635.0FalseNoneNoneFalseNoneFalse853.150
3385165119216None657 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - GF - PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- etc., complete with all leadm149.49149.4930.0FalseNoneNoneFalseNoneFalse4484.70
3385166119216None657 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - FF - PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- etc., complete with all leadm150.99150.9910.0FalseNoneNoneFalseNoneFalse1509.90
3385167119216None647 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - GF - PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm309.93309.9325.0FalseNoneNoneFalseNoneFalse7748.250
3385168119216None647 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with - FF - PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm313.03313.0310.0FalseNoneNoneFalseNoneFalse3130.30
3385169119216None13.47 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter - GF ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3385170119216None37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone) - GF-do- in slabs upto 7.50 cms thick ---- etc., complete with all leadm154.58154.585.0FalseNoneNoneFalseNoneFalse772.90
3385171119216None37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone) - GF -do- in slabs upto 10 cms thick ---- etc., complete with all leadm185.26185.265.0FalseNoneNoneFalseNoneFalse926.30
3385172119216None37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone) - GF-do- in slabs upto 7.50 cms thicknos ---- etc., complete with all leadNos154.58154.585.0FalseNoneNoneFalseNoneFalse772.90
3385173119216None37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone) - GF -do- in slabs upto 10 cms thick ---- etc., complete with all leadNos185.26185.265.0FalseNoneNoneFalseNoneFalse926.30
3385174119216None14.31 - V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete - GF ---- etc., complete with all leadNos1482.791482.792.0FalseNoneNoneFalseNoneFalse2965.580
3385175119216None14.31 - V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete - FF ---- etc., complete with all leadNos1497.621497.622.0FalseNoneNoneFalseNoneFalse2995.240
3385176119216None14.44 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. - GF ---- etc., complete with all leadEach13641.6513641.652.0FalseNoneNoneFalseNoneFalse27283.30
3385177119216None14.44 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete - FF ---- etc., complete with all leadEach13778.0713778.072.0FalseNoneNoneFalseNoneFalse27556.140
3385178119216None4.11.2 - V-2 1Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm - GF ---- etc., complete with all leadNos6176.666176.667.0FalseNoneNoneFalseNoneFalse43236.620
3385179119216None166 V-2C.P. Brass stop cock (concealed) 15 mm - GF ---- etc., complete with all leadEach645.17645.174.0FalseNoneNoneFalseNoneFalse2580.680
3385180119216None14.7.1 - V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps - GF ---- etc., complete with all leadNos3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3385181119216None14.7.1 - V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps - FF ---- etc., complete with all leadNos3783.323783.322.0FalseNoneNoneFalseNoneFalse7566.640
3385182119216None13.32.1 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 15 mm nominal dia Pipes - GF ---- etc., complete with all leadMtr375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3385183119216None13.32.1 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 20 mm nominal dia Pipes - GF ---- etc., complete with all leadMtr460.64460.6435.0FalseNoneNoneFalseNoneFalse16122.40
3385184119216None13.32.1 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 15 mm nominal dia Pipes - FF ---- etc., complete with all leadMtr379.78379.785.0FalseNoneNoneFalseNoneFalse1898.90
3385185119216None13.32.1 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 20 mm nominal dia Pipes - FF ---- etc., complete with all leadMtr465.24465.2420.0FalseNoneNoneFalseNoneFalse9304.80
3385186119216None13.33.1 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 15 mm nominal dia Pipes - GF ---- etc., complete with all leadMtr263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3385187119216None13.33.3 - V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc - 25 mm nominal dia Pipes - FF ---- etc., complete with all leadMtr359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3385188119216None13.4.1 - V-2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) - 25 mm nominal bore - GF ---- etc., complete with all leadEach667.25667.254.0FalseNoneNoneFalseNoneFalse2669.00
3385189119216None13.53 V-2Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 (CATCH BASIN) - GF ---- etc., complete with all leadNos6857.296857.298.0FalseNoneNoneFalseNoneFalse54858.320
3385190119216None12.112.2Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms - GF ---- etc., complete with all leadNos330.4330.44.0FalseNoneNoneFalseNoneFalse1321.60
3385191119216None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank - GF ---- etc., complete with all leadl10.9410.942000.0FalseNoneNoneFalseNoneFalse21880.00
3385192119216NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards - GF - 10Cms X 7.5Cms ---- etc., complete with all leadNos371.7371.710.0FalseNoneNoneFalseNoneFalse3717.00
3385193119216NoneDATA RATEAir Vent Cowel - 75mm ---- etc., complete with all leadNos413.0413.01.0FalseNoneNoneFalseNoneFalse413.00
3385194119216NoneDATA RATEAir Vent Cowel - 110mm ---- etc., complete with all leadNos590.0590.01.0FalseNoneNoneFalseNoneFalse590.00
3385195119216NoneData RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ) ---- etc., complete with all leadNos2183.02183.04.0FalseNoneNoneFalseNoneFalse8732.00
17194847600000NoneNoneBuildingsCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) AT TLH RANEBENNUR - ELECTRICAL WORK (SLICE-02)576569.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385196119217None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 1) Point wiring using class A Materials a) Short point upto 3 Mtr from tapping point to out let via switch. ---- etc., complete with all leadEach326.94326.9415.0FalseNoneNoneFalseNoneFalse4904.10
3385197119217None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 1) Point wiring using class A Materials b) Medium point above 3 Mtr upto 6Mtr from tapping point to out let via switch. ---- etc., complete with all leadEach460.64460.6420.0FalseNoneNoneFalseNoneFalse9212.80
3385198119217None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 1) Point wiring using class A Materials c) Long point above 6mtr upto 10Mtr from tapping point to out let via switch. ---- etc., complete with all leadEach674.55674.5520.0FalseNoneNoneFalseNoneFalse13491.00
3385199119217None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 1) Point wiring using class A Materials Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadEach822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3385200119217None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- etc., complete with all leadEach167.73167.7320.0FalseNoneNoneFalseNoneFalse3354.60
3385201119217None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way ---- etc., complete with all leadEach193.25193.254.0FalseNoneNoneFalseNoneFalse773.00
3385202119217None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- etc., complete with all leadEach267.39267.394.0FalseNoneNoneFalseNoneFalse1069.560
3385203119217None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8 Way ---- etc., complete with all leadEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3385204119217None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- etc., complete with all leadEach387.71387.7130.0FalseNoneNoneFalseNoneFalse11631.30
3385205119217None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 1 to 3 Module ---- etc., complete with all leadEach166.51166.5120.0FalseNoneNoneFalseNoneFalse3330.20
3385206119217None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 4 Module ---- etc., complete with all leadEach212.7212.74.0FalseNoneNoneFalseNoneFalse850.80
3385207119217None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 6 Module ---- etc., complete with all leadEach284.4284.44.0FalseNoneNoneFalseNoneFalse1137.60
3385208119217None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 8 Module ---- etc., complete with all leadEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3385209119217None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 Module ---- etc., complete with all leadEach418.1418.130.0FalseNoneNoneFalseNoneFalse12543.00
3385210119217None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 6Amps one way Switch ---- etc., complete with all leadEach123.97123.97100.0FalseNoneNoneFalseNoneFalse12397.00
3385211119217None3.6.2Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 6Amps Two way Switch ---- etc., complete with all leadEach201.76201.764.0FalseNoneNoneFalseNoneFalse807.040
3385212119217None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 6Amps 3way socket ---- etc., complete with all leadEach207.83207.8355.0FalseNoneNoneFalseNoneFalse11430.650
3385213119217None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - Stepped Fan Regulator. ---- etc., complete with all leadEach433.9433.910.0FalseNoneNoneFalseNoneFalse4339.00
3385214119217None3.6.7Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 16Amps one way switch ---- etc., complete with all leadEach218.77218.7740.0FalseNoneNoneFalseNoneFalse8750.80
3385215119217None3.6.9Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 32Amps DP switch ---- etc., complete with all leadEach396.22396.224.0FalseNoneNoneFalseNoneFalse1584.880
3385216119217None3.6.10Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - Using Group "A" materials - 6/16Amps universal socket ---- etc., complete with all leadEach286.83286.8340.0FalseNoneNoneFalseNoneFalse11473.20
3385217119217None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board - 6A Lamp Holder ---- etc., complete with all leadNo86.2986.2930.0FalseNoneNoneFalseNoneFalse2588.70
3385218119217None1.13Supplyin and Fixing Metal Fan Box with Round Hook ---- etc., complete with all leadNo142.2142.210.0FalseNoneNoneFalseNoneFalse1422.00
3385219119217None1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick ---- etc., complete with all leadMtr80.2280.22300.0FalseNoneNoneFalseNoneFalse24066.00
3385220119217None1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick ---- etc., complete with all leadMtr94.894.8400.0FalseNoneNoneFalseNoneFalse37920.00
3385221119217None1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 32mm dia 2.5mm thick ---- etc., complete with all leadMtr125.19125.1950.0FalseNoneNoneFalseNoneFalse6259.50
3385222119217None1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary - 19/20mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.6510.0FalseNoneNoneFalseNoneFalse826.50
3385223119217None1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary - 25mm dia 2mm thick ---- etc., complete with all leadMtr96.0296.02200.0FalseNoneNoneFalseNoneFalse19204.00
3385224119217None1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary - 32mm dia 2.5mm thick ---- etc., complete with all leadMtr120.32120.3210.0FalseNoneNoneFalseNoneFalse1203.20
3385225119217None2.3.2Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multis and copper conductor single core cable in open or consealed system of wiring - 1.5 sqmm ---- etc., complete with all leadMtr31.631.6200.0FalseNoneNoneFalseNoneFalse6320.00
3385226119217None2.3.3Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multis and copper conductor single core cable in open or consealed system of wiring - 2.5 sqmm ---- etc., complete with all leadMtr51.0551.05500.0FalseNoneNoneFalseNoneFalse25525.00
3385227119217None2.3.4Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multis and copper conductor single core cable in open or consealed system of wiring - 4 sqmm ---- etc., complete with all leadMtr76.5776.57500.0FalseNoneNoneFalseNoneFalse38285.00
3385228119217None2.3.5Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multis and copper conductor single core cable in open or consealed system of wiring - 6 sqmm ---- etc., complete with all leadMtr111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3385229119217None2.3.6Wiring for lighting/power circuit using one of PVC insulated 1100v grade, multis and copper conductor single core cable in open or consealed system of wiring - 10 sqmm ---- etc., complete with all leadMtr202.97202.9750.0FalseNoneNoneFalseNoneFalse10148.50
3385230119217None5.19.3Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure - I- Single Door - 8 Way SP & N ---- etc., complete with all leadEach1813.381813.382.0FalseNoneNoneFalseNoneFalse3626.760
3385231119217None5.19.4MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure - I- Single Door - 12 Way SP & N ---- etc., complete with all leadEach2264.292264.291.0FalseNoneNoneFalseNoneFalse2264.290
3385232119217None6 Way TP & NMCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- III - Double Door ---- etc., complete with all leadEach6004.086004.081.0FalseNoneNoneFalseNoneFalse6004.080
3385233119217None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach504.39504.3930.0FalseNoneNoneFalseNoneFalse15131.70
3385234119217None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3385235119217None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32Amps DP ---- etc., complete with all leadEach898.18898.184.0FalseNoneNoneFalseNoneFalse3592.720
3385236119217None5.20.4Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board - 32-40 A 2 pole ---- etc., complete with all leadEach5541.015541.011.0FalseNoneNoneFalseNoneFalse5541.010
3385237119217None5.20.3Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board - 32-40 Amps 4 pole ---- etc., complete with all leadEach6255.666255.661.0FalseNoneNoneFalseNoneFalse6255.660
3385238119217NoneBSR-32.07LT UG CABLES "1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ---- etc., complete with all leadKm220536.76220536.760.1FalseNoneNoneFalseNoneFalse22053.6760
3385239119217NoneBSR-31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm19639.6519639.650.1FalseNoneNoneFalseNoneFalse1963.9650
3385240119217NoneSR 19-20 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) - 25mm dia ---- etc., complete with all leadEach102.09102.096.0FalseNoneNoneFalseNoneFalse612.540
3385241119217NoneBSR 49.05Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class - 50mm ---- etc., complete with all leadMtr465.5465.510.0FalseNoneNoneFalseNoneFalse4655.00
3385242119217NoneSR 19-20-6.17.7Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes - 25 sqmm Long Barrel ---- etc., complete with all leadEach9.729.726.0FalseNoneNoneFalseNoneFalse58.320
3385243119217NoneBSR-29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed - In soil (hard) ---- etc., complete with all leadCum472.79472.7920.0FalseNoneNoneFalseNoneFalse9455.80
3385244119217None12.56 V-6Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. ---- etc., complete with all leadMtr4266.054266.052.0FalseNoneNoneFalseNoneFalse8532.10
3385245119217None12.58.125x3mm GI strip ---- etc., complete with all leadEach99.6699.6640.0FalseNoneNoneFalseNoneFalse3986.40
3385246119217None11.3.2EARTHING - ELECTRICAL FIXTURES - Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition - LED light fighting 1 x 4 - 20/22 w ---- etc., complete with all leadEach838.63838.6325.0FalseNoneNoneFalseNoneFalse20965.750
3385247119217None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition - LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.636.0FalseNoneNoneFalseNoneFalse6453.780
3385248119217None11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition - 7 W, 6500K ---- etc., complete with all leadEach181.09181.096.0FalseNoneNoneFalseNoneFalse1086.540
3385249119217None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130 lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source - LED Streetlight 40W ---- etc., complete with all leadNo4890.774890.772.0FalseNoneNoneFalseNoneFalse9781.540
3385250119217None6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.385.0FalseNoneNoneFalseNoneFalse9066.90
3385251119217None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system - 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.758.0FalseNoneNoneFalseNoneFalse29014.00
3385252119217None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps -On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2836.0FalseNoneNoneFalseNoneFalse5338.080
3385253119217None13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.838.0FalseNoneNoneFalseNoneFalse1662.640
3385254119217None13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.29859.295.0FalseNoneNoneFalseNoneFalse4296.450
3385255119217None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories - Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
3385256119217None13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
3385257119217None5.42.2L.T.PANEL - Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete - 16SWG ---- etc., complete with all leadSq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
3385258119217None5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete -100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.962.0FalseNoneNoneFalseNoneFalse5991.920
3385259119217None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint - 40x40x6mm ---- etc., complete with all leadMtr370.7370.76.0FalseNoneNoneFalseNoneFalse2224.20
3385260119217None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint - 50x100x50x6mm C channel ---- etc., complete with all leadMtr918.84918.844.0FalseNoneNoneFalseNoneFalse3675.360
3385261119217None5.11.2Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution) - 100 A ---- etc., complete with all leadEach8617.198617.191.0FalseNoneNoneFalseNoneFalse8617.190
3385262119217None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) - FOUR POLE - 100Amps 25kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3385263119217None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32Amps SP ---- etc., complete with all leadEach504.39504.392.0FalseNoneNoneFalseNoneFalse1008.780
3385264119217None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32Amps DP ---- etc., complete with all leadEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3385265119217None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 50-63Amps TPN ---- etc., complete with all leadEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3385266119217None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3385267119217None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.936.0FalseNoneNoneFalseNoneFalse3755.580
3385268119217None5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all leadEach683.05683.056.0FalseNoneNoneFalseNoneFalse4098.30
17194847600000NoneNoneBuildingsCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) IN THE PREMISES OF TLH MUNDAGOD - CIVIL WORK (SLICE-03)4365941.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385269119218NoneI-2.5(ii)A P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete with all lead100 Sqm519.39519.392.17FalseNoneNoneFalseNoneFalse1127.07630
3385270119218NoneI-1.12 P-8 V-1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum125.55125.5587.0FalseNoneNoneFalseNoneFalse10922.850
3385271119218NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum134.8134.883.96FalseNoneNoneFalseNoneFalse11317.8080
3385272119218NoneI-1.15.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum479.74479.7435.84FalseNoneNoneFalseNoneFalse17193.88160
3385273119218NoneI-1.9 P-7 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum351.55351.5548.12FalseNoneNoneFalseNoneFalse16916.5860
3385274119218NoneI-1.8 P-7 V-1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum626.44626.4495.75FalseNoneNoneFalseNoneFalse59981.630
3385275119218NoneI-2.1.3 P-15 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7915.067915.0614.15FalseNoneNoneFalseNoneFalse111998.0990
3385276119218NoneI-2.2.3 P-15 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) Footings ---- etc., complete with all leadCum8624.878624.8717.25FalseNoneNoneFalseNoneFalse148779.00750
3385277119218NoneI-2.2.3 P-15 V-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) PEDESTALS ---- etc., complete with all leadCum9211.029211.022.59FalseNoneNoneFalseNoneFalse23856.54180
3385278119218NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) Columns GF ---- etc., complete with all leadCum15374.315374.39.0FalseNoneNoneFalseNoneFalse138368.70
3385279119218NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) PLINTH BEAM, RCC SLAB GF ---- etc., complete with all leadCum13565.5613565.5637.61FalseNoneNoneFalseNoneFalse510200.71160
3385280119218NoneI-2.5.2 P-16 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Formwork included) RCC BEAMS, LINTELS GF ---- etc., complete with all leadCum14469.9314469.9313.17FalseNoneNoneFalseNoneFalse190568.97810
3385281119218NoneI-2.1.4 P-15 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Cill concrete GF ---- etc., complete with all leadCum9038.039038.032.84FalseNoneNoneFalseNoneFalse25668.00520
3385282119218NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy GF ---- etc., complete with all leadNo.269.61269.6110.0FalseNoneNoneFalseNoneFalse2696.10
3385283119218NoneI-8.16a P-44 V-2KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1636.141636.144.5FalseNoneNoneFalseNoneFalse7362.630
3385284119218NoneI-2.11 a P-84 V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification GF ---- etc., complete with all leadTonne118226.37118226.376.65FalseNoneNoneFalseNoneFalse786205.36050
3385285119218NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr38.9438.9454.0FalseNoneNoneFalseNoneFalse2102.760
3385286119218NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. GF ---- etc., complete with all leadRmtr86.1486.1454.0FalseNoneNoneFalseNoneFalse4651.560
3385287119218NoneI-10.21 P-72 V-2Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification ---- etc., complete with all leadCum2878.442878.441.62FalseNoneNoneFalseNoneFalse4663.07280
3385288119218NoneI-6.33 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GF ---- etc., complete with all leadSqm1731.31731.3203.84FalseNoneNoneFalseNoneFalse352908.1920
3385289119218NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GF ---- etc., complete with all leadSqm1459.051459.0567.33FalseNoneNoneFalseNoneFalse98237.83650
3385290119218NoneI-12.93.2 P-111 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 125mm GF ---- etc., complete with all leadm1009.71009.770.8FalseNoneNoneFalseNoneFalse71486.760
3385291119218NoneI-12.60 P-105 V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GF ---- etc., complete with all leadNos1390.321390.3212.0FalseNoneNoneFalseNoneFalse16683.840
3385292119218NoneI-12.61 P-105 V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. GF ---- etc., complete with all leadNos1308.381308.3812.0FalseNoneNoneFalseNoneFalse15700.560
3385293119218NoneI-12.62 P-105 V-2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete GF ---- etc., complete with all leadNos313.22313.2224.0FalseNoneNoneFalseNoneFalse7517.280
3385294119218NoneI-12.63 P-105 V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GF ---- etc., complete with all leadNos171.81171.8124.0FalseNoneNoneFalseNoneFalse4123.440
3385295119218NoneI-12.64 P-105 V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GF ---- etc., complete with all leadNos72.6972.6912.0FalseNoneNoneFalseNoneFalse872.280
3385296119218NoneI-12.75.1 P-108 V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) GF ---- etc., complete with all leadNos363.44363.4424.0FalseNoneNoneFalseNoneFalse8722.560
3385297119218NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GF ---- etc., complete with all leadNos79.379.372.0FalseNoneNoneFalseNoneFalse5709.60
3385298119218NoneI-309 (0115) P-XI S.R 2018-19Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. GF ---- etc., complete with all leadRmtr16.816.880.4FalseNoneNoneFalseNoneFalse1350.720
3385299119218NoneI-12.94.2 P-111 V-2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum oxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35mm thickness GF ---- etc., complete with all leadSqm5340.595340.5931.5FalseNoneNoneFalseNoneFalse168228.5850
3385300119218NoneI-12.88 P-110 V-2Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete with all leadSqm7123.427123.4227.0FalseNoneNoneFalseNoneFalse192332.340
3385301119218NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete with all leadSqm7558.237558.231.44FalseNoneNoneFalseNoneFalse10883.85120
3385302119218NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GF ---- etc., complete with all leadKg222.03222.03597.24FalseNoneNoneFalseNoneFalse132605.19720
3385303119218NoneI-12.93.1 P-112 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)12.93.1 Size 62 x 100mm GF ---- etc., complete with all leadm927.76927.7619.8FalseNoneNoneFalseNoneFalse18369.6480
3385304119218NoneI-12.94.1 P-112 V-2Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 12.94.130 mm thickness GF ---- etc., complete with all leadSqm4605.784605.786.3FalseNoneNoneFalseNoneFalse29016.4140
3385305119218NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GF ---- etc., complete with all leadNos1472.261472.2612.0FalseNoneNoneFalseNoneFalse17667.120
3385306119218NoneI-8.4.2 P-41 V-2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) GF ---- etc., complete with all leadSqm412.34412.34408.83FalseNoneNoneFalseNoneFalse168576.96220
3385307119218NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GF ---- etc., complete with all leadSqm132.16132.16679.91FalseNoneNoneFalseNoneFalse89856.90560
3385308119218NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) GF ---- etc., complete with all leadSqm520.71520.71280.26FalseNoneNoneFalseNoneFalse145934.18460
3385309119218NoneI-15.36 P-118 S.R 2018-19KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) GF ---- etc., complete with all leadRmtr42.4842.48807.0FalseNoneNoneFalseNoneFalse34281.360
3385310119218NoneI-10.5.2 P-70 S.R 2018-19Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.210.0FalseNoneNoneFalseNoneFalse2832.00
3385311119218NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GF ---- etc., complete with all leadRmtr68.7268.72256.0FalseNoneNoneFalseNoneFalse17592.320
3385312119218NoneI-9.17.2 P-61 V-2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm GF ---- etc., complete with all leadSqm1552.881552.88168.8FalseNoneNoneFalseNoneFalse262126.1440
3385313119218NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm389.87389.8742.84FalseNoneNoneFalseNoneFalse16702.03080
3385314119218NoneI-9.23 P-63 V-2Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. GF ---- etc., complete with all leadSqm3259.073259.0735.27FalseNoneNoneFalseNoneFalse114947.39890
3385315119218NoneI-15.7 P-150 V-2Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) GF ---- etc., complete with all leadSqm812.78812.788.34FalseNoneNoneFalseNoneFalse6778.58520
3385316119218NoneI-9.11 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. GF ---- etc., complete with all leadSqm1174.91174.98.34FalseNoneNoneFalseNoneFalse9798.6660
3385317119218NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GF ---- etc., complete with all leadSqm1915.01915.042.84FalseNoneNoneFalseNoneFalse82038.60
3385318119218NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm167.84167.84679.91FalseNoneNoneFalseNoneFalse114116.09440
3385319119218NoneI-8.32 P-45 V-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm206.17206.17280.26FalseNoneNoneFalseNoneFalse57781.20420
3385320119218NoneI-8.34.3 P-47 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm66.0866.0828.44FalseNoneNoneFalseNoneFalse1879.31520
3385321119218NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm151.98151.9828.44FalseNoneNoneFalseNoneFalse4322.31120
3385322119218NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete with all leadSqm70.0470.0475.6FalseNoneNoneFalseNoneFalse5295.0240
3385323119218NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadRmtr340.38340.3812.0FalseNoneNoneFalseNoneFalse4084.560
17194847600000NoneNoneBuildingsCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) IN THE PREMISES OF TLH MUNDAGOD - WATER SUPPLY WORK (SLICE - 04)170329.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385324119219NoneI-14.28.2.2 P-136 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines GF ---- etc., complete with all leadEach121.59121.598.0FalseNoneNoneFalseNoneFalse972.720
3385325119219NoneI-16.7.4 P-191 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes GF ---- etc., complete with all leadm183.7183.715.0FalseNoneNoneFalseNoneFalse2755.50
3385326119219NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GF ---- etc., complete with all leadm162.56162.5640.0FalseNoneNoneFalseNoneFalse6502.40
3385327119219NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GF ---- etc., complete with all leadm337.01337.0135.0FalseNoneNoneFalseNoneFalse11795.350
3385328119219NoneI-13.47 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter GF ---- etc., complete with all leadm260.36260.3620.0FalseNoneNoneFalseNoneFalse5207.20
3385329119219NoneI-14.31 P-136 V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. GF ---- etc., complete with all leadEach1612.351612.354.0FalseNoneNoneFalseNoneFalse6449.40
3385330119219NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GF ---- etc., complete with all leadEach7899.27899.24.0FalseNoneNoneFalseNoneFalse31596.80
3385331119219NoneI-14.11.2 P-126 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GF ---- etc., complete with all leadNos.6716.376716.372.0FalseNoneNoneFalseNoneFalse13432.740
3385332119219NoneI-13.15 P-119 V-2Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. GF ---- etc., complete with all leadEach958.16958.164.0FalseNoneNoneFalseNoneFalse3832.640
3385333119219NoneI-14.7.1 P-124 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps GF ---- etc., complete with all leadEach4073.174073.174.0FalseNoneNoneFalseNoneFalse16292.680
3385334119219NoneI-13.32.1 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes GF ---- etc., complete with all leadm408.37408.375.0FalseNoneNoneFalseNoneFalse2041.850
3385335119219NoneI-13.32.2 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GF ---- etc., complete with all leadm500.89500.8945.0FalseNoneNoneFalseNoneFalse22540.050
3385336119219NoneI-13.33.2 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes GF ---- etc., complete with all leadm286.79286.7920.0FalseNoneNoneFalseNoneFalse5735.80
3385337119219NoneI-13.33.3 P-120 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes GF ---- etc., complete with all leadm391.19391.1930.0FalseNoneNoneFalseNoneFalse11735.70
3385338119219NoneI-16.9 P-162 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadNos.7208.017208.012.0FalseNoneNoneFalseNoneFalse14416.020
3385339119219NoneI-13.58 P-127 V-2Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete GF ---- etc., complete with all leadNos.457.27457.272.0FalseNoneNoneFalseNoneFalse914.540
3385340119219NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl11.8911.891000.0FalseNoneNoneFalseNoneFalse11890.00
3385341119219NoneI-14.95 P-145 V-2Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy GF ---- etc., complete with all leadNos.1108.821108.822.0FalseNoneNoneFalseNoneFalse2217.640
17194847600000NoneNoneBuildingsCONSTRUCTION OF BLOCK PUBLIC HEALTH UNIT (BPHU) IN THE PREMISES OF TLH MUNDAGOD - ELECTRICAL WORK (SLICE - 05)426688.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3385342119220None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint355.51355.5110.0FalseNoneNoneFalseNoneFalse3555.10
3385343119220None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint500.89500.8912.0FalseNoneNoneFalseNoneFalse6010.680
3385344119220None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadPoint733.49733.4915.0FalseNoneNoneFalseNoneFalse11002.350
3385345119220None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadPoint894.72894.725.0FalseNoneNoneFalseNoneFalse4473.60
3385346119220None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all leadEach182.38182.385.0FalseNoneNoneFalseNoneFalse911.90
3385347119220None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way ---- etc., complete with all leadEach210.13210.135.0FalseNoneNoneFalseNoneFalse1050.650
3385348119220None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach233.92233.923.0FalseNoneNoneFalseNoneFalse701.760
3385349119220None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach290.75290.752.0FalseNoneNoneFalseNoneFalse581.50
3385350119220None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all leadEach344.94344.943.0FalseNoneNoneFalseNoneFalse1034.820
3385351119220None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach421.59421.5914.0FalseNoneNoneFalseNoneFalse5902.260
3385352119220None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach181.06181.065.0FalseNoneNoneFalseNoneFalse905.30
3385353119220None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach212.78212.785.0FalseNoneNoneFalseNoneFalse1063.90
3385354119220None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all leadEach231.28231.283.0FalseNoneNoneFalseNoneFalse693.840
3385355119220None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all leadEach309.25309.252.0FalseNoneNoneFalseNoneFalse618.50
3385356119220None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all leadEach375.33375.333.0FalseNoneNoneFalseNoneFalse1125.990
3385357119220None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all leadEach454.63454.6314.0FalseNoneNoneFalseNoneFalse6364.820
3385358119220None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach134.8134.865.0FalseNoneNoneFalseNoneFalse8762.00
3385359119220None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach225.99225.9925.0FalseNoneNoneFalseNoneFalse5649.750
3385360119220None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach471.81471.8110.0FalseNoneNoneFalseNoneFalse4718.10
3385361119220None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach237.89237.892.0FalseNoneNoneFalseNoneFalse475.780
3385362119220None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach430.84430.848.0FalseNoneNoneFalseNoneFalse3446.720
3385363119220None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all leadEach311.9311.910.0FalseNoneNoneFalseNoneFalse3119.00
3385364119220NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo154.63154.6310.0FalseNoneNoneFalseNoneFalse1546.30
3385365119220None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadm87.2387.23220.0FalseNoneNoneFalseNoneFalse19190.60
3385366119220None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadm103.08103.08260.0FalseNoneNoneFalseNoneFalse26800.80
3385367119220None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadm136.12136.1270.0FalseNoneNoneFalseNoneFalse9528.40
3385368119220None1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadm89.8789.87150.0FalseNoneNoneFalseNoneFalse13480.50
3385369119220None1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm104.41104.41100.0FalseNoneNoneFalseNoneFalse10441.00
3385370119220None1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm130.84130.8430.0FalseNoneNoneFalseNoneFalse3925.20
3385371119220None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm34.3634.36450.0FalseNoneNoneFalseNoneFalse15462.00
3385372119220None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm55.5155.51400.0FalseNoneNoneFalseNoneFalse22204.00
3385373119220None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm83.2683.26200.0FalseNoneNoneFalseNoneFalse16652.00
3385374119220None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm121.59121.59170.0FalseNoneNoneFalseNoneFalse20670.30
3385375119220None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N ---- etc., complete with all leadEach2462.142462.142.0FalseNoneNoneFalseNoneFalse4924.280
3385376119220None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TPN DB ---- etc., complete with all leadEach5336.625336.621.0FalseNoneNoneFalseNoneFalse5336.620
3385377119220None5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach548.46548.4618.0FalseNoneNoneFalseNoneFalse9872.280
3385378119220None5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach1071.821071.821.0FalseNoneNoneFalseNoneFalse1071.820
3385379119220None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all leadEach976.66976.664.0FalseNoneNoneFalseNoneFalse3906.640
3385380119220None5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole ---- etc., complete with all leadEach5652.485652.481.0FalseNoneNoneFalseNoneFalse5652.480
3385381119220NoneBSR-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all leadKm184427.96184427.960.08FalseNoneNoneFalseNoneFalse14754.23680
3385382119220NoneBSR-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm21355.7321355.730.1FalseNoneNoneFalseNoneFalse2135.5730
3385383119220NoneSR 19-20 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia ---- etc., complete with all leadEach111.01111.018.0FalseNoneNoneFalseNoneFalse888.080
3385384119220NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5624.735624.732.0FalseNoneNoneFalseNoneFalse11249.460
3385385119220NoneSR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.1299.1210.0FalseNoneNoneFalseNoneFalse991.20
3385386119220None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach911.9911.914.0FalseNoneNoneFalseNoneFalse12766.60
3385387119220None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1169.621169.628.0FalseNoneNoneFalseNoneFalse9356.960
3385388119220None11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach196.92196.924.0FalseNoneNoneFalseNoneFalse787.680
3385389119220NoneI-12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach83.2683.264.0FalseNoneNoneFalseNoneFalse333.040
3385390119220NoneI-11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- etc., complete with all leadNo5318.125318.121.0FalseNoneNoneFalseNoneFalse5318.120
3385391119220NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1971.831971.834.0FalseNoneNoneFalseNoneFalse7887.320
3385392119220None6.3.1Supplying capacitor type ceiling fan complete with down rodnblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3943.653943.654.0FalseNoneNoneFalseNoneFalse15774.60
3385393119220None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach161.24161.2428.0FalseNoneNoneFalseNoneFalse4514.720
3385394119220NoneI-13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach416.3416.38.0FalseNoneNoneFalseNoneFalse3330.40
3385395119220NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach934.37934.374.0FalseNoneNoneFalseNoneFalse3737.480
3385396119220None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1930.861930.861.0FalseNoneNoneFalseNoneFalse1930.860
3385397119220NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach214.1214.11.0FalseNoneNoneFalseNoneFalse214.10
3385398119220None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.570.5725000.0FalseNoneNoneFalseNoneFalse14250.00
3385399119220None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm3257.743257.742.0FalseNoneNoneFalseNoneFalse6515.480
3385400119220None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm403.09403.098.0FalseNoneNoneFalseNoneFalse3224.720
3385401119220None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm999.13999.138.0FalseNoneNoneFalseNoneFalse7993.040
3385402119220None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 63A/100Amps 25kA ---- etc., complete with all leadEach11216.4211216.421.0FalseNoneNoneFalseNoneFalse11216.420
3385403119220None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPN ---- etc., complete with all leadEach4022.954022.951.0FalseNoneNoneFalseNoneFalse4022.950
3385404119220None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach4081.14081.11.0FalseNoneNoneFalseNoneFalse4081.10
3385405119220NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
3385406119220NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach680.62680.623.0FalseNoneNoneFalseNoneFalse2041.860
3385407119220NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all leadEach742.74742.743.0FalseNoneNoneFalseNoneFalse2228.220
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194847610000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194847610000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194847610000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194847610000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194847610000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194848240000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17194848330000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17194848420000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17194848490000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17194848560000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17194848620000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17194848670000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17194848740000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17194848800000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17194848890000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17194848980000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17194849040000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17194849100000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17194849170000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17194849250000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17194849310000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17194849360000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17194849430000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17194849490000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2023-24 & 2024-25None
17194849560000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.49.80 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 259.00 Cum,2)RCC and PCC 154.00Cum,3)Steel Reinforcement for RCC work 10.00 tonne,4)Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall 308.00Sqm, 5)Flooring/Dadooing(Vitrified/Granite/Ceramic/Cement concrete/cladding/dadooing) 369.00 Sqm, 6)Plastering 1490.00 Sqm, 7)Painting 1660.00 Sqm, 8)M.S grill work 1020.00 kgs 9)WPC 82.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.7.50 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.3.50 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No of Persons.1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One), 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneKPWD Class-III & above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration certificate issued by competent authority
NoneNoneNoneNoneClause ITT 3.2(a):To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2019-20 to 2023-24).The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.99.60 Lakhs. Note: For Clause 3.2 (a) the Turn over certificate and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.30.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime ContractorFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx2.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level of existing commitments and ongoing works to be completed during the next 6 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- existing commitments and on-going works
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet issued by charted accountantTrueTechnical Bid
KPWD Registration Certificate Class-III & aboveTrueTechnical Bid
ESI and PF certificate and latest paid receiptTrueTechnical Bid
Workdone certificate issued by the officer not below the rank of EETrueTechnical Bid
GST certificate and latest paid receiptTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone