1719487195000 | 0 | None | None | Buildings | Construction of One Room to Govt Urdu Higher Primary School at Mediagrahara, Bengaluru Urban City. Under Viveka Yojane/2022-23 | 1383085.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3385774 | 119240 | None | Code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work - In all kinds of soils upto 300 mm depth with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 84.37 | 84.37 | 63.75 | False | None | None | False | None | False | 5378.5875 | 0 | 3385775 | 119240 | None | Code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils Depth upto 3 m with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 94.75 | 94.75 | 59.54 | False | None | None | False | None | False | 5641.415 | 0 | 3385776 | 119240 | None | Code03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 123.31 | 123.31 | 145.8 | False | None | None | False | None | False | 17978.598 | 0 | 3385777 | 119240 | None | Code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 6757.39 | 6757.39 | 14.68 | False | None | None | False | None | False | 99198.4852 | 0 | 3385778 | 119240 | None | Code05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Column Footing with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 8385.27 | 8385.27 | 10.53 | False | None | None | False | None | False | 88296.8931 | 0 | 3385779 | 119240 | None | Code06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Columns with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 13199.88 | 13199.88 | 0.7 | False | None | None | False | None | False | 9239.916 | 0 | 3385780 | 119240 | None | Code07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Plinth Beam with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 11646.95 | 11646.95 | 2.8 | False | None | None | False | None | False | 32611.46 | 0 | 3385781 | 119240 | None | Code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Columns Above PB Level with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 13650.03 | 13650.03 | 2.61 | False | None | None | False | None | False | 35626.5783 | 0 | 3385782 | 119240 | None | Code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Lintels and Roof Beam with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 12847.08 | 12847.08 | 3.97 | False | None | None | False | None | False | 51002.9076 | 0 | 3385783 | 119240 | None | Code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Roof with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 12044.14 | 12044.14 | 8.47 | False | None | None | False | None | False | 102013.8658 | 0 | 3385784 | 119240 | None | Code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Chejja with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 11642.67 | 11642.67 | 0.12 | False | None | None | False | None | False | 1397.1204 | 0 | 3385785 | 119240 | None | Code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Kg | 119.42 | 119.42 | 2381.4 | False | None | None | False | None | False | 284386.788 | 0 | 3385786 | 119240 | None | Code13 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 6946.9 | 6946.9 | 18.22 | False | None | None | False | None | False | 126572.518 | 0 | 3385787 | 119240 | None | Code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Cum | 264.79 | 264.79 | 21.02 | False | None | None | False | None | False | 5565.8858 | 0 | 3385788 | 119240 | None | Code15 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 1377.89 | 1377.89 | 95.63 | False | None | None | False | None | False | 131767.6207 | 0 | 3385789 | 119240 | None | Code16 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 258.3 | 258.3 | 9.06 | False | None | None | False | None | False | 2340.198 | 0 | 3385790 | 119240 | None | Code17 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 276.47 | 276.47 | 49.96 | False | None | None | False | None | False | 13812.4412 | 0 | 3385791 | 119240 | None | Code18 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 298.54 | 298.54 | 83.45 | False | None | None | False | None | False | 24913.163 | 0 | 3385792 | 119240 | None | Code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 398.49 | 398.49 | 147.54 | False | None | None | False | None | False | 58793.2146 | 0 | 3385793 | 119240 | None | Code20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 4750.68 | 4750.68 | 2.52 | False | None | None | False | None | False | 11971.7136 | 0 | 3385794 | 119240 | None | Code21 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Kg | 155.76 | 155.76 | 108.0 | False | None | None | False | None | False | 16822.08 | 0 | 3385795 | 119240 | None | Code22 | Providing and fixing M.S. grills of required pattern in frames of win-dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Kg | 188.21 | 188.21 | 120.96 | False | None | None | False | None | False | 22765.8816 | 0 | 3385796 | 119240 | None | Code23 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 1547.22 | 1547.22 | 51.52 | False | None | None | False | None | False | 79712.7744 | 0 | 3385797 | 119240 | None | Code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 107.73 | 107.73 | 125.08 | False | None | None | False | None | False | 13474.8684 | 0 | 3385798 | 119240 | None | Code25 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 107.73 | 107.73 | 125.08 | False | None | None | False | None | False | 13474.8684 | 0 | 3385799 | 119240 | None | Code26 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 51.92 | 51.92 | 150.16 | False | None | None | False | None | False | 7796.3072 | 0 | 3385800 | 119240 | None | Code27 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 85.67 | 85.67 | 150.16 | False | None | None | False | None | False | 12864.2072 | 0 | 3385801 | 119240 | None | Code28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 168.74 | 168.74 | 6.84 | False | None | None | False | None | False | 1154.1816 | 0 | 3385802 | 119240 | None | Code29 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sqm | 967.01 | 967.01 | 52.0 | False | None | None | False | None | False | 50284.52 | 0 | 3385803 | 119240 | None | Code30 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0,110mm dia with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | m | 451.7 | 451.7 | 7.0 | False | None | None | False | None | False | 3161.9 | 0 | 3385804 | 119240 | None | Code31 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (confirming toIS-694: and latest amendments) without control switchshall be fixed on the existing plastic sheet/ gang box, theother end of the wires shall be terminated with sufficientloose length in a wood/PVC round block. complete for eachoutlet - Short point upto 3Mtr from tapping point to out let via switchbox with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Point | 188.8 | 188.8 | 4.0 | False | None | None | False | None | False | 755.2 | 0 | 3385805 | 119240 | None | Code32 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (confirming toIS-694: and latest amendments) without control switchshall be fixed on the existing plastic sheet/ gang box, theother end of the wires shall be terminated with sufficientloose length in a wood/PVC round block. complete for eachoutlet - Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Point | 295.0 | 295.0 | 4.0 | False | None | None | False | None | False | 1180.0 | 0 | 3385806 | 119240 | None | Code33 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (confirming toIS-694: and latest amendments) without control switchshall be fixed on the existing plastic sheet/ gang box, theother end of the wires shall be terminated with sufficientloose length in a wood/PVC round block. complete for eachoutlet - Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Point | 442.5 | 442.5 | 4.0 | False | None | None | False | None | False | 1770.0 | 0 | 3385807 | 119240 | None | Code34 | Supplying and fixing superior quality modular switchmounting polycarbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing metal/PVC box - 1 to 3 Module with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 129.8 | 129.8 | 1.0 | False | None | None | False | None | False | 129.8 | 0 | 3385808 | 119240 | None | Code35 | Supplying and flush mounting teak wooden box without frontplank, made of not less than 12mm thick wood, after duegroove cutting, Finishing with necessary cement plastering - 12"x9"x3" (300x228x76) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 101.48 | 101.48 | 16.0 | False | None | None | False | None | False | 1623.68 | 0 | 3385809 | 119240 | None | Code36 | Supplying and flush mounting teak wooden box without frontplank, made of not less than 12mm thick wood, after duegroove cutting, Finishing with necessary cement plastering - 12"x12"x3" (300x300x76mm) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 120.36 | 120.36 | 10.0 | False | None | None | False | None | False | 1203.6 | 0 | 3385810 | 119240 | None | Code37 | Supplying and flush mounting teak wooden box without frontplank, made of not less than 12mm thick wood, after duegroove cutting, Finishing with necessary cement plastering - 10"x7"x3" (254x178x76mm) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 90.86 | 90.86 | 6.0 | False | None | None | False | None | False | 545.16 | 0 | 3385811 | 119240 | None | Code38 | Supplying 6A flush type socket and 6 amps flush type SPswitch either surface/flush mounting in existing gang box orin 4mm thick plastic sheet and fixing over a flush mountedwooden box and wiring using necessary capacity wires asrequired as per IS 1293 and IS 3654 - 6Amps 2 Way with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 132.16 | 132.16 | 4.0 | False | None | None | False | None | False | 528.64 | 0 | 3385812 | 119240 | None | Code39 | Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall - 16-18Way with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 212.4 | 212.4 | 1.0 | False | None | None | False | None | False | 212.4 | 0 | 3385813 | 119240 | None | Code40 | Supplying 4mm thick plastic sheet with necessary nitchesfor fixing switches, regulators etc., and fixing on existingwooden or metal box using N.F. screws with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Sq CM | 0.32 | 0.32 | 1000.0 | False | None | None | False | None | False | 320.0 | 0 | 3385814 | 119240 | None | Code41 | Supplying heavy gauge PVC conduit pipe …….dia .......mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc., and fixing using inverted woodplugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an intervalof 700mm using NF screws - 25mm dia 2mm thick with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Mtr | 76.7 | 76.7 | 100.0 | False | None | None | False | None | False | 7670.0 | 0 | 3385815 | 119240 | None | Code42 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898 - 6-32Amps SP with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 512.12 | 512.12 | 1.0 | False | None | None | False | None | False | 512.12 | 0 | 3385816 | 119240 | None | Code43 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealedsystem of wiring with specified IS-694:confirming to latestamendments - 2.5 sqmm with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Mtr | 37.76 | 37.76 | 450.0 | False | None | None | False | None | False | 16992.0 | 0 | 3385817 | 119240 | None | Code44 | Supplying and fixing PVC/metal conduit Deep junctionbox - 32mm deep junction box with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 70.8 | 70.8 | 5.0 | False | None | None | False | None | False | 354.0 | 0 | 3385818 | 119240 | None | Code45 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V @ 50/60Hz & Power factor 0.9 along withCE approved. 2 years Warranty against any manufacturingdefect working under standard electrical condition - LED light fighting 2x 4' - 20 /22 w with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 737.5 | 737.5 | 3.0 | False | None | None | False | None | False | 2212.5 | 0 | 3385819 | 119240 | None | Code46 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps - On wall / ceiling / Rafter / Girders with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 129.8 | 129.8 | 3.0 | False | None | None | False | None | False | 389.4 | 0 | 3385820 | 119240 | None | Code47 | Supplying of Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS:374/79 and alsocomply with IS:1709/1984 with latest amendment, Ratedvoltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %,Rated current As per IS:374/79, Rated power factor 0.9lagging(min), Rated speed 350 +/- 10% RPM, Rated airdelivery 210 +/- 10% Cubic Meter Minimum, Rated servicevalue 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per ISspecification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two MegaOhms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & FanSpeed as per IS:374/1979 with latest amendment, 2 yearmanufacturer Warranty - 56" Sweep 5 Star (1400mm) with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 4720.0 | 4720.0 | 3.0 | False | None | None | False | None | False | 14160.0 | 0 | 3385821 | 119240 | None | Code48 | Supplying & fixing of Porcelain fuse channel with cut outon existing wooden/panel using necessary nuts, bolts andwashers - 200Amps with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work. | Each | 835.44 | 835.44 | 3.0 | False | None | None | False | None | False | 2506.32 | 0 |
|