createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719489071430
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd682000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-07-2024 16:00:00
tenderQueryClose09-07-2024 16:00:00
technicalBidOpen16-07-2024 16:01:00
publishedDate27-06-2024 17:31:13
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate10-07-2024 16:00:18
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPraveen B A
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1719489071508
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT526
titleCONSTRUCTION OF HEALTH & WELLNESS CENTRE AT 1.MARILINGANADODDI 2. RAYASHETTIPURA 3. HANAGANAHALLI IN MANDYA TALUK 4. ILLENAHALLI IN PANDAVAPURA TALUK 5. NAGUVINAHALLI IN SRIRANGAPATNA TALUK 6. AGRAHARABACHAHALLI IN K.R PET TALUK 7 NELLIGERE IN NAGAMANGALA TALUK OF MANDYA DISTRICT.
descriptionCONSTRUCTION OF HEALTH & WELLNESS CENTRE AT 1.MARILINGANADODDI 2. RAYASHETTIPURA 3. HANAGANAHALLI IN MANDYA TALUK 4. ILLENAHALLI IN PANDAVAPURA TALUK 5. NAGUVINAHALLI IN SRIRANGAPATNA TALUK 6. AGRAHARABACHAHALLI IN K.R PET TALUK 7 NELLIGERE IN NAGAMANGALA TALUK OF MANDYA DISTRICT.
categoryWORKS
categoryTextWorks
ecv45444530.53
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount45500000.0
groupOverheadTotal0.0
fileNumberHFW/AEEMDY/Wellnesscentre/MandyaPKG
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194890720000NoneNoneBuildings1 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT MARILINGANADODDI IN MANDYA TALUKA OF MANDYA DISTRICT. (Civil Works) (Slice-1)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386588119269NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3386589119269NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3386590119269NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3386591119269NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3386592119269NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3386593119269NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3386594119269NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3386595119269NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3386596119269NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3386597119269NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3386598119269NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3386599119269NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3386600119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3386601119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3386602119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3386603119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3386604119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3386605119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3386606119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3386607119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3386608119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3386609119269NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3386610119269NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3386611119269NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3386612119269NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3386613119269NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3386614119269NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3386615119269NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3386616119269NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3386617119269NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3386618119269NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3386619119269NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3386620119269NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3386621119269NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3386622119269NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3386623119269NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3386624119269NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3386625119269NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3386626119269NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3386627119269NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3386628119269NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3386629119269NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3386630119269NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3386631119269NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3386632119269NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3386633119269NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3386634119269NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3386635119269NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3386636119269NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3386637119269NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3386638119269NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3386639119269NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3386640119269NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3386641119269NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3386642119269NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3386643119269NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3386644119269NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3386645119269NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3386646119269NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3386647119269NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3386648119269NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3386649119269NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3386650119269NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3386651119269NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3386652119269NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3386653119269NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3386654119269NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3386655119269NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3386656119269NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3386657119269NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3386658119269NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3386659119269NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3386660119269NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3386661119269NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3386662119269NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3386663119269NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3386664119269NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3386665119269NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3386666119269NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3386667119269NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3386668119269NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3386669119269NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3386670119269NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3386671119269NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3386672119269NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3386673119269NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3386674119269NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3386675119269NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3386676119269NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3386677119269NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3386678119269NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3386679119269NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3386680119269NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3386681119269NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings1 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT MARILINGANADODDI IN MANDYA TALUKA OF MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-1)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386682119270NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3386683119270NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3386684119270NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3386685119270NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3386686119270NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3386687119270NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3386688119270NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3386689119270NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3386690119270NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3386691119270NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3386692119270NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3386693119270NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3386694119270NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3386695119270NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3386696119270NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3386697119270NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3386698119270NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3386699119270NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3386700119270NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3386701119270NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3386702119270NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3386703119270NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3386704119270NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3386705119270NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3386706119270NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3386707119270NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3386708119270NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3386709119270NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3386710119270NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3386711119270NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3386712119270NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3386713119270NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3386714119270NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3386715119270NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings1 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT MARILINGANADODDI IN MANDYA TALUKA OF MANDYA DISTRICT. (Electrical Works) (Slice-1)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386716119271None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3386717119271None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3386718119271None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3386719119271None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3386720119271None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3386721119271None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3386722119271None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3386723119271None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3386724119271None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3386725119271None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3386726119271None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3386727119271None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3386728119271None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3386729119271None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3386730119271None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3386731119271None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3386732119271None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3386733119271None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3386734119271None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3386735119271None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3386736119271NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3386737119271None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3386738119271None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3386739119271None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3386740119271None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3386741119271None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3386742119271None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3386743119271None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3386744119271None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3386745119271None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3386746119271None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3386747119271NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3386748119271None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3386749119271None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3386750119271NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3386751119271None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3386752119271None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3386753119271NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3386754119271NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3386755119271None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3386756119271None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3386757119271NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3386758119271None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3386759119271None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3386760119271None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3386761119271None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3386762119271None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3386763119271NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3386764119271NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3386765119271NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3386766119271NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings2 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT RAYASHETTIPURA IN MANDYA TALUK, MANDYA DISTRICT. (Civil Works) (Slice-2)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386767119272NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3386768119272NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3386769119272NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3386770119272NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3386771119272NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3386772119272NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3386773119272NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3386774119272NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3386775119272NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3386776119272NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3386777119272NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3386778119272NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3386779119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3386780119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3386781119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3386782119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3386783119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3386784119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3386785119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3386786119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3386787119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3386788119272NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3386789119272NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3386790119272NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3386791119272NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3386792119272NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3386793119272NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3386794119272NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3386795119272NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3386796119272NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3386797119272NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3386798119272NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3386799119272NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3386800119272NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3386801119272NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3386802119272NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3386803119272NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3386804119272NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3386805119272NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3386806119272NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3386807119272NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3386808119272NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3386809119272NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3386810119272NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3386811119272NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3386812119272NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3386813119272NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3386814119272NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3386815119272NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3386816119272NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3386817119272NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3386818119272NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3386819119272NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3386820119272NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3386821119272NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3386822119272NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3386823119272NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3386824119272NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3386825119272NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3386826119272NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3386827119272NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3386828119272NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3386829119272NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3386830119272NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3386831119272NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3386832119272NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3386833119272NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3386834119272NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3386835119272NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3386836119272NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3386837119272NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3386838119272NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3386839119272NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3386840119272NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3386841119272NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3386842119272NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3386843119272NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3386844119272NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3386845119272NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3386846119272NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3386847119272NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3386848119272NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3386849119272NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3386850119272NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3386851119272NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3386852119272NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3386853119272NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3386854119272NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3386855119272NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3386856119272NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3386857119272NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3386858119272NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3386859119272NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3386860119272NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings2 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT RAYASHETTIPURA IN MANDYA TALUK, MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-2)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386861119273NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3386862119273NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3386863119273NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3386864119273NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3386865119273NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3386866119273NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3386867119273NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3386868119273NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3386869119273NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3386870119273NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3386871119273NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3386872119273NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3386873119273NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3386874119273NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3386875119273NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3386876119273NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3386877119273NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3386878119273NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3386879119273NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3386880119273NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3386881119273NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3386882119273NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3386883119273NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3386884119273NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3386885119273NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3386886119273NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3386887119273NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3386888119273NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3386889119273NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3386890119273NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3386891119273NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3386892119273NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3386893119273NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3386894119273NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings2 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT RAYASHETTIPURA IN MANDYA TALUK, MANDYA DISTRICT. (Electrical Works) (Slice-2)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386895119274None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3386896119274None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3386897119274None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3386898119274None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3386899119274None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3386900119274None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3386901119274None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3386902119274None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3386903119274None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3386904119274None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3386905119274None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3386906119274None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3386907119274None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3386908119274None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3386909119274None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3386910119274None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3386911119274None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3386912119274None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3386913119274None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3386914119274None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3386915119274NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3386916119274None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3386917119274None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3386918119274None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3386919119274None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3386920119274None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3386921119274None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3386922119274None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3386923119274None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3386924119274None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3386925119274None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3386926119274NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3386927119274None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3386928119274None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3386929119274NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3386930119274None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3386931119274None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3386932119274NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3386933119274NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3386934119274None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3386935119274None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3386936119274NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3386937119274None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3386938119274None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3386939119274None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3386940119274None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3386941119274None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3386942119274NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3386943119274NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3386944119274NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3386945119274NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings3 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT HANAGANAHALLIIN MANDYA TALUK MANDYA DISTRICT. (Civil Works) (Slice-3)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386946119275NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3386947119275NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3386948119275NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3386949119275NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3386950119275NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3386951119275NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3386952119275NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3386953119275NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3386954119275NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3386955119275NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3386956119275NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3386957119275NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3386958119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3386959119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3386960119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3386961119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3386962119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3386963119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3386964119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3386965119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3386966119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3386967119275NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3386968119275NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3386969119275NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3386970119275NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3386971119275NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3386972119275NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3386973119275NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3386974119275NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3386975119275NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3386976119275NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3386977119275NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3386978119275NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3386979119275NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3386980119275NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3386981119275NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3386982119275NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3386983119275NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3386984119275NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3386985119275NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3386986119275NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3386987119275NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3386988119275NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3386989119275NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3386990119275NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3386991119275NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3386992119275NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3386993119275NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3386994119275NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3386995119275NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3386996119275NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3386997119275NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3386998119275NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3386999119275NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3387000119275NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3387001119275NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3387002119275NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3387003119275NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3387004119275NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3387005119275NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3387006119275NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3387007119275NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3387008119275NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3387009119275NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3387010119275NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3387011119275NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3387012119275NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3387013119275NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3387014119275NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3387015119275NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3387016119275NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3387017119275NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3387018119275NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3387019119275NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3387020119275NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3387021119275NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3387022119275NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3387023119275NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3387024119275NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3387025119275NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3387026119275NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3387027119275NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3387028119275NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3387029119275NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3387030119275NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3387031119275NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3387032119275NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3387033119275NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3387034119275NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3387035119275NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3387036119275NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3387037119275NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3387038119275NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3387039119275NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings3 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT HANAGANAHALLIIN MANDYA TALUK MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-3)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387040119276NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3387041119276NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3387042119276NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3387043119276NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3387044119276NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3387045119276NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3387046119276NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3387047119276NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3387048119276NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3387049119276NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3387050119276NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3387051119276NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3387052119276NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3387053119276NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3387054119276NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3387055119276NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3387056119276NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3387057119276NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3387058119276NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3387059119276NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3387060119276NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3387061119276NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3387062119276NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3387063119276NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3387064119276NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3387065119276NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3387066119276NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3387067119276NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3387068119276NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3387069119276NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3387070119276NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3387071119276NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3387072119276NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3387073119276NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings3 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT HANAGANAHALLIIN MANDYA TALUK MANDYA DISTRICT. (Electrical Works) (Slice-3)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387074119277None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3387075119277None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3387076119277None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3387077119277None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3387078119277None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3387079119277None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3387080119277None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3387081119277None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3387082119277None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3387083119277None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3387084119277None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3387085119277None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3387086119277None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3387087119277None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3387088119277None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3387089119277None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3387090119277None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3387091119277None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3387092119277None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3387093119277None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3387094119277NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3387095119277None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3387096119277None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3387097119277None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3387098119277None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3387099119277None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3387100119277None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3387101119277None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3387102119277None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3387103119277None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3387104119277None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3387105119277NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3387106119277None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3387107119277None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3387108119277NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3387109119277None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3387110119277None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3387111119277NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3387112119277NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3387113119277None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3387114119277None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3387115119277NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3387116119277None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3387117119277None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3387118119277None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3387119119277None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3387120119277None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3387121119277NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3387122119277NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3387123119277NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3387124119277NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings4 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT ILLENAHALLI IN PANDAVAPURA TALUK MANDYA DISTRICT. (Civil Works) (Slice-4)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387125119278NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3387126119278NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3387127119278NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3387128119278NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3387129119278NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3387130119278NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3387131119278NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3387132119278NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3387133119278NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3387134119278NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3387135119278NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3387136119278NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3387137119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3387138119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3387139119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3387140119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3387141119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3387142119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3387143119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3387144119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3387145119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3387146119278NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3387147119278NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3387148119278NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3387149119278NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3387150119278NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3387151119278NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3387152119278NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3387153119278NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3387154119278NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3387155119278NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3387156119278NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3387157119278NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3387158119278NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3387159119278NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3387160119278NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3387161119278NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3387162119278NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3387163119278NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3387164119278NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3387165119278NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3387166119278NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3387167119278NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3387168119278NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3387169119278NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3387170119278NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3387171119278NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3387172119278NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3387173119278NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3387174119278NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3387175119278NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3387176119278NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3387177119278NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3387178119278NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3387179119278NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3387180119278NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3387181119278NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3387182119278NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3387183119278NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3387184119278NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3387185119278NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3387186119278NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3387187119278NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3387188119278NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3387189119278NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3387190119278NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3387191119278NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3387192119278NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3387193119278NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3387194119278NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3387195119278NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3387196119278NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3387197119278NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3387198119278NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3387199119278NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3387200119278NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3387201119278NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3387202119278NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3387203119278NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3387204119278NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3387205119278NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3387206119278NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3387207119278NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3387208119278NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3387209119278NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3387210119278NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3387211119278NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3387212119278NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3387213119278NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3387214119278NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3387215119278NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3387216119278NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3387217119278NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3387218119278NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings4 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT ILLENAHALLI IN PANDAVAPURA TALUK MANDYA DISTRICT. (Water supply & Sanitary Works) (Slice-4)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387219119279NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3387220119279NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3387221119279NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3387222119279NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3387223119279NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3387224119279NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3387225119279NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3387226119279NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3387227119279NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3387228119279NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3387229119279NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3387230119279NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3387231119279NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3387232119279NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3387233119279NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3387234119279NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3387235119279NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3387236119279NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3387237119279NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3387238119279NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3387239119279NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3387240119279NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3387241119279NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3387242119279NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3387243119279NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3387244119279NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3387245119279NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3387246119279NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3387247119279NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3387248119279NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3387249119279NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3387250119279NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3387251119279NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3387252119279NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings4 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT ILLENAHALLI IN PANDAVAPURA TALUK MANDYA DISTRICT. (Electrical Works) (Slice-4)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387253119280None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3387254119280None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3387255119280None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3387256119280None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3387257119280None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3387258119280None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3387259119280None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3387260119280None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3387261119280None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3387262119280None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3387263119280None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3387264119280None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3387265119280None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3387266119280None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3387267119280None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3387268119280None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3387269119280None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3387270119280None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3387271119280None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3387272119280None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3387273119280NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3387274119280None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3387275119280None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3387276119280None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3387277119280None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3387278119280None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3387279119280None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3387280119280None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3387281119280None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3387282119280None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3387283119280None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3387284119280NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3387285119280None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3387286119280None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3387287119280NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3387288119280None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3387289119280None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3387290119280NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3387291119280NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3387292119280None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3387293119280None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3387294119280NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3387295119280None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3387296119280None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3387297119280None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3387298119280None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3387299119280None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3387300119280NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3387301119280NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3387302119280NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3387303119280NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings5 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NAGUVINAHALLI IN SRIRANGAPATNA TALUK MANDYA DISTRICT. (Civil Works) (Slice-5)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387304119281NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3387305119281NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3387306119281NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3387307119281NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3387308119281NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3387309119281NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3387310119281NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3387311119281NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3387312119281NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3387313119281NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3387314119281NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3387315119281NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3387316119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3387317119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3387318119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3387319119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3387320119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3387321119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3387322119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3387323119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3387324119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3387325119281NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3387326119281NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3387327119281NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3387328119281NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3387329119281NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3387330119281NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3387331119281NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3387332119281NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3387333119281NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3387334119281NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3387335119281NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3387336119281NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3387337119281NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3387338119281NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3387339119281NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3387340119281NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3387341119281NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3387342119281NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3387343119281NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3387344119281NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3387345119281NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3387346119281NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3387347119281NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3387348119281NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3387349119281NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3387350119281NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3387351119281NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3387352119281NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3387353119281NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3387354119281NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3387355119281NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3387356119281NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3387357119281NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3387358119281NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3387359119281NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3387360119281NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3387361119281NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3387362119281NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3387363119281NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3387364119281NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3387365119281NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3387366119281NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3387367119281NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3387368119281NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3387369119281NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3387370119281NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3387371119281NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3387372119281NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3387373119281NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3387374119281NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3387375119281NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3387376119281NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3387377119281NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3387378119281NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3387379119281NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3387380119281NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3387381119281NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3387382119281NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3387383119281NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3387384119281NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3387385119281NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3387386119281NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3387387119281NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3387388119281NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3387389119281NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3387390119281NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3387391119281NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3387392119281NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3387393119281NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3387394119281NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3387395119281NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3387396119281NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3387397119281NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings5 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NAGUVINAHALLI IN SRIRANGAPATNA TALUK MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-5)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387398119282NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3387399119282NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3387400119282NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3387401119282NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3387402119282NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3387403119282NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3387404119282NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3387405119282NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3387406119282NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3387407119282NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3387408119282NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3387409119282NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3387410119282NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3387411119282NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3387412119282NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3387413119282NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3387414119282NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3387415119282NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3387416119282NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3387417119282NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3387418119282NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3387419119282NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3387420119282NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3387421119282NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3387422119282NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3387423119282NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3387424119282NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3387425119282NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3387426119282NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3387427119282NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3387428119282NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3387429119282NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3387430119282NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3387431119282NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings5 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NAGUVINAHALLI IN SRIRANGAPATNA TALUK MANDYA DISTRICT. (Electrical Works) (Slice-5)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387432119283None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3387433119283None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3387434119283None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3387435119283None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3387436119283None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3387437119283None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3387438119283None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3387439119283None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3387440119283None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3387441119283None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3387442119283None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3387443119283None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3387444119283None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3387445119283None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3387446119283None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3387447119283None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3387448119283None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3387449119283None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3387450119283None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3387451119283None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3387452119283NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3387453119283None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3387454119283None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3387455119283None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3387456119283None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3387457119283None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3387458119283None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3387459119283None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3387460119283None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3387461119283None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3387462119283None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3387463119283NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3387464119283None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3387465119283None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3387466119283NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3387467119283None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3387468119283None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3387469119283NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3387470119283NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3387471119283None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3387472119283None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3387473119283NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3387474119283None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3387475119283None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3387476119283None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3387477119283None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3387478119283None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3387479119283NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3387480119283NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3387481119283NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3387482119283NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings6 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT AGRAHARABACHAHALLI IN K.R PET TALUK MANDYA DISTRICT. (Civil Works) (Slice-6)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387483119284NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3387484119284NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3387485119284NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3387486119284NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3387487119284NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3387488119284NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3387489119284NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3387490119284NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3387491119284NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3387492119284NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3387493119284NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3387494119284NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3387495119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3387496119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3387497119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3387498119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3387499119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3387500119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3387501119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3387502119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3387503119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3387504119284NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3387505119284NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3387506119284NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3387507119284NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3387508119284NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3387509119284NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3387510119284NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3387511119284NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3387512119284NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3387513119284NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3387514119284NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3387515119284NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3387516119284NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3387517119284NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3387518119284NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3387519119284NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3387520119284NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3387521119284NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3387522119284NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3387523119284NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3387524119284NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3387525119284NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3387526119284NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3387527119284NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3387528119284NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3387529119284NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3387530119284NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3387531119284NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3387532119284NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3387533119284NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3387534119284NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3387535119284NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3387536119284NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3387537119284NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3387538119284NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3387539119284NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3387540119284NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3387541119284NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3387542119284NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3387543119284NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3387544119284NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3387545119284NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3387546119284NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3387547119284NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3387548119284NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3387549119284NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3387550119284NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3387551119284NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3387552119284NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3387553119284NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3387554119284NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3387555119284NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3387556119284NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3387557119284NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3387558119284NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3387559119284NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3387560119284NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3387561119284NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3387562119284NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3387563119284NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3387564119284NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3387565119284NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3387566119284NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3387567119284NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3387568119284NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3387569119284NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3387570119284NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3387571119284NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3387572119284NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3387573119284NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3387574119284NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3387575119284NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3387576119284NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings6 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT AGRAHARABACHAHALLI IN K.R PET TALUK MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-6)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387577119285NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3387578119285NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3387579119285NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3387580119285NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3387581119285NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3387582119285NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3387583119285NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3387584119285NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3387585119285NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3387586119285NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3387587119285NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3387588119285NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3387589119285NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3387590119285NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3387591119285NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3387592119285NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3387593119285NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3387594119285NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3387595119285NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3387596119285NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3387597119285NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3387598119285NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3387599119285NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3387600119285NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3387601119285NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3387602119285NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3387603119285NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3387604119285NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3387605119285NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3387606119285NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3387607119285NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3387608119285NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3387609119285NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3387610119285NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings6 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT AGRAHARABACHAHALLI IN K.R PET TALUK MANDYA DISTRICT. (Electrical Works) (Slice-6)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387611119286None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3387612119286None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3387613119286None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3387614119286None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3387615119286None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3387616119286None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3387617119286None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3387618119286None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3387619119286None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3387620119286None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3387621119286None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3387622119286None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3387623119286None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3387624119286None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3387625119286None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3387626119286None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3387627119286None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3387628119286None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3387629119286None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3387630119286None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3387631119286NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3387632119286None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3387633119286None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3387634119286None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3387635119286None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3387636119286None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3387637119286None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3387638119286None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3387639119286None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3387640119286None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3387641119286None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3387642119286NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3387643119286None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3387644119286None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3387645119286NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3387646119286None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3387647119286None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3387648119286NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3387649119286NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3387650119286None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3387651119286None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3387652119286NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3387653119286None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3387654119286None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3387655119286None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3387656119286None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3387657119286None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3387658119286NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3387659119286NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3387660119286NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3387661119286NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17194890720000NoneNoneBuildings7 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NELLIGERE IN NAGAMANGALA TALUK OF MANDYA DISTRICT. (Civil Works) (Slice-7)5775452.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387662119287NoneV-3 P-9 I-2.5iiaClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.100 Sqm463.74463.747.5FalseNoneNoneFalseNoneFalse3478.050
3387663119287NoneV-1 P-8 I-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.175.0FalseNoneNoneFalseNoneFalse8407.50
3387664119287NoneV-1 P-8 I-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum120.36120.36221.3FalseNoneNoneFalseNoneFalse26635.6680
3387665119287NoneV-1 P-8 I-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specificationsSqm139.24139.2410.42FalseNoneNoneFalseNoneFalse1450.88080
3387666119287NoneV-1 P-15 I-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum7067.027067.0229.11FalseNoneNoneFalseNoneFalse205720.95220
3387667119287NoneV-1 P-15 I-2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7418.667418.6637.57FalseNoneNoneFalseNoneFalse278719.05620
3387668119287NoneV-1 P-7 I-1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.88177.04FalseNoneNoneFalseNoneFalse55569.31520
3387669119287NoneV-1 P-7 I-1.87Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum559.32559.32194.02FalseNoneNoneFalseNoneFalse108519.26640
3387670119287NoneV-2 P-9 I-5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6620.986620.987.2FalseNoneNoneFalseNoneFalse47671.0560
3387671119287NoneV-2 P-9 I-5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7321.97321.95.4FalseNoneNoneFalseNoneFalse39538.260
3387672119287NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GFCum8074.748074.7444.67FalseNoneNoneFalseNoneFalse360698.63580
3387673119287NoneV-1 P-16 I-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FFCum8155.498155.4920.89FalseNoneNoneFalseNoneFalse170368.18610
3387674119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, PedestalCum593.49593.4929.44FalseNoneNoneFalseNoneFalse17472.34560
3387675119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GFCum5652.325652.329.18FalseNoneNoneFalseNoneFalse51888.29760
3387676119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FFCum5708.845708.843.47FalseNoneNoneFalseNoneFalse19809.67480
3387677119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAMCum4037.374037.378.86FalseNoneNoneFalseNoneFalse35771.09820
3387678119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GFCum4844.844844.8412.29FalseNoneNoneFalseNoneFalse59543.08360
3387679119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FFCum4893.294893.295.85FalseNoneNoneFalseNoneFalse28625.74650
3387680119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GFCum4037.374037.3714.08FalseNoneNoneFalseNoneFalse56846.16960
3387681119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FFCum4077.744077.7418.49FalseNoneNoneFalseNoneFalse75397.41260
3387682119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GFCum3633.633633.631.03FalseNoneNoneFalseNoneFalse3742.63890
3387683119287NoneV-1 P-111Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FFCum3669.973669.970.26FalseNoneNoneFalseNoneFalse954.19220
3387684119287NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GFCum7366.747366.744.12FalseNoneNoneFalseNoneFalse30350.96880
3387685119287NoneV-1 P-15 I-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FFCum7440.417440.411.69FalseNoneNoneFalseNoneFalse12574.29290
3387686119287NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GFTonne105559.26105559.268.55FalseNoneNoneFalseNoneFalse902531.6730
3387687119287NoneV-1 P-18 I-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.56FalseNoneNoneFalseNoneFalse272934.0160
3387688119287NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFCum9403.429403.4237.38FalseNoneNoneFalseNoneFalse351499.83960
3387689119287NoneV-2 P-14 I-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFCum9497.459497.4522.8FalseNoneNoneFalseNoneFalse216541.860
3387690119287NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GFSqm1151.681151.6835.55FalseNoneNoneFalseNoneFalse40942.2240
3387691119287NoneV-2 P-14 I-6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FFSqm1163.21163.245.11FalseNoneNoneFalseNoneFalse52471.9520
3387692119287NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GFCum116601.7116601.70.45FalseNoneNoneFalseNoneFalse52470.7650
3387693119287NoneV-2 P-100 I-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FFCum117767.72117767.720.45FalseNoneNoneFalseNoneFalse52995.4740
3387694119287NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFNos1198.881198.884.0FalseNoneNoneFalseNoneFalse4795.520
3387695119287NoneV-2 P-104 I-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFNos1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3387696119287NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GFEach442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3387697119287NoneV-2 P-219 I-22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FFEach446.93446.934.0FalseNoneNoneFalseNoneFalse1787.720
3387698119287NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GFEach531.0531.08.0FalseNoneNoneFalseNoneFalse4248.00
3387699119287NoneV-2 P-219 I-22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FFEach536.31536.318.0FalseNoneNoneFalseNoneFalse4290.480
3387700119287NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GFEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
3387701119287NoneV-2 P-219 I-22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FFEach178.77178.774.0FalseNoneNoneFalseNoneFalse715.080
3387702119287NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GFEach59.059.016.0FalseNoneNoneFalseNoneFalse944.00
3387703119287NoneV-2 P-219 I-22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FFEach59.5959.5916.0FalseNoneNoneFalseNoneFalse953.440
3387704119287NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GFEach64.964.912.0FalseNoneNoneFalseNoneFalse778.80
3387705119287NoneV-2 P-69 I-10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FFEach65.5565.5512.0FalseNoneNoneFalseNoneFalse786.60
3387706119287NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GFMtr61.3661.3624.0FalseNoneNoneFalseNoneFalse1472.640
3387707119287NoneV-2 P-205 I-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FFMtr61.9761.9724.0FalseNoneNoneFalseNoneFalse1487.280
3387708119287NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GFSqm3919.963919.9615.36FalseNoneNoneFalseNoneFalse60210.58560
3387709119287NoneV-2 P-105 I-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FFSqm3959.163959.1615.36FalseNoneNoneFalseNoneFalse60812.69760
3387710119287NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm7730.187730.189.84FalseNoneNoneFalseNoneFalse76064.97120
3387711119287NoneV-2 P-110 I-12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm7807.487807.489.6FalseNoneNoneFalseNoneFalse74951.8080
3387712119287NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GFSqm6748.426748.420.72FalseNoneNoneFalseNoneFalse4858.86240
3387713119287NoneV-2 P-109 I-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FFSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3387714119287NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKgs198.24198.24206.64FalseNoneNoneFalseNoneFalse40964.31360
3387715119287NoneV-2 P-85 I-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FFKgs200.22200.22206.64FalseNoneNoneFalseNoneFalse41373.46080
3387716119287NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GFMtr828.36828.369.8FalseNoneNoneFalseNoneFalse8117.9280
3387717119287NoneV-2 P-111 I-12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FFMtr836.64836.649.8FalseNoneNoneFalseNoneFalse8199.0720
3387718119287NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GFSqm4112.34112.33.15FalseNoneNoneFalseNoneFalse12953.7450
3387719119287NoneV-2 P-112 I-12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FFSqm4153.424153.423.15FalseNoneNoneFalseNoneFalse13083.2730
3387720119287NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm411.82411.82241.84FalseNoneNoneFalseNoneFalse99594.54880
3387721119287NoneV-2 P-42 I-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm415.94415.94141.19FalseNoneNoneFalseNoneFalse58726.56860
3387722119287NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm248.98248.9893.2FalseNoneNoneFalseNoneFalse23204.9360
3387723119287NoneV-2 P-43 I-8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm251.47251.4772.81FalseNoneNoneFalseNoneFalse18309.53070
3387724119287NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GFSqm118.0118.0335.04FalseNoneNoneFalseNoneFalse39534.720
3387725119287NoneV-2 P-50 I-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FFSqm119.18119.18214.0FalseNoneNoneFalseNoneFalse25504.520
3387726119287NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GFSqm437.78437.78163.75FalseNoneNoneFalseNoneFalse71686.4750
3387727119287NoneV-2 P-42 I-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FFSqm442.16442.16146.23FalseNoneNoneFalseNoneFalse64657.05680
3387728119287NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GFMtr40.1240.12676.2FalseNoneNoneFalseNoneFalse27129.1440
3387729119287NoneV-2 P-43 I-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FFMtr40.5240.52676.2FalseNoneNoneFalseNoneFalse27399.6240
3387730119287NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GFMtr61.3661.36271.01FalseNoneNoneFalseNoneFalse16629.17360
3387731119287NoneV-2 P-54 I-8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FFMtr61.9761.97271.01FalseNoneNoneFalseNoneFalse16794.48970
3387732119287NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GFSqm1351.11351.156.4FalseNoneNoneFalseNoneFalse76202.040
3387733119287NoneV-2 P-60 I-9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FFSqm1364.611364.6152.46FalseNoneNoneFalseNoneFalse71587.44060
3387734119287NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GFSqm329.22329.2267.22FalseNoneNoneFalseNoneFalse22130.16840
3387735119287NoneV-2 P-40 I-8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FFSqm332.51332.5167.22FalseNoneNoneFalseNoneFalse22351.32220
3387736119287NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GFSqm1049.021049.025.98FalseNoneNoneFalseNoneFalse6273.13960
3387737119287NoneV-2 P-60 I-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FFSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3387738119287NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1709.821709.8267.22FalseNoneNoneFalseNoneFalse114934.10040
3387739119287NoneV-2 P-64 I-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FFSqm1726.921726.926.3FalseNoneNoneFalseNoneFalse10879.5960
3387740119287NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm149.86149.86335.04FalseNoneNoneFalseNoneFalse50209.09440
3387741119287NoneV-2 P-48 I-8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm151.36151.36214.0FalseNoneNoneFalseNoneFalse32391.040
3387742119287NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm210.04210.04163.75FalseNoneNoneFalseNoneFalse34394.050
3387743119287NoneV-2 P-46 I-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm212.14212.14146.23FalseNoneNoneFalseNoneFalse31021.23220
3387744119287NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm135.7135.762.22FalseNoneNoneFalseNoneFalse8443.2540
3387745119287NoneV-2 P-48 I-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm137.06137.0662.22FalseNoneNoneFalseNoneFalse8527.87320
3387746119287NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GFSqm47.247.225.2FalseNoneNoneFalseNoneFalse1189.440
3387747119287NoneV-2 P-48 I-8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FFSqm47.6747.6725.2FalseNoneNoneFalseNoneFalse1201.2840
3387748119287NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GFSqm3365.363365.3651.69FalseNoneNoneFalseNoneFalse173955.45840
3387749119287NoneV-2 P-63 I-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FFSqm3399.013399.0113.5FalseNoneNoneFalseNoneFalse45886.6350
3387750119287NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GFKgs666.7666.7288.0FalseNoneNoneFalseNoneFalse192009.60
3387751119287NoneV-2 P-85 I-11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FFKgs673.37673.37119.07FalseNoneNoneFalseNoneFalse80178.16590
3387752119287NoneV-2 P-87 I-11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GFKgs533.36533.3688.2FalseNoneNoneFalseNoneFalse47042.3520
3387753119287NoneItemThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeLS47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3387754119287NoneV-2 P-84 I-11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs163.69163.6975.6FalseNoneNoneFalseNoneFalse12374.9640
3387755119287NoneV-2 P-149 I-15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm983.34983.34113.23FalseNoneNoneFalseNoneFalse111343.58820
17194890720000NoneNoneBuildings7 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NELLIGERE IN NAGAMANGALA TALUK OF MANDYA DISTRICT. (Water Supply & Sanitary Works) (Slice-7)278247.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387756119288NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm GFm61.3661.3620.0FalseNoneNoneFalseNoneFalse1227.20
3387757119288NoneI-655 P-A44 V-5PVC pipe-OD 50mm & 6Kg/Sqcm FFm61.9761.9725.0FalseNoneNoneFalseNoneFalse1549.250
3387758119288NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GFm145.14145.1420.0FalseNoneNoneFalseNoneFalse2902.80
3387759119288NoneI-657 P-A44 V-5PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FFm146.59146.5925.0FalseNoneNoneFalseNoneFalse3664.750
3387760119288NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GFm300.9300.940.0FalseNoneNoneFalseNoneFalse12036.00
3387761119288NoneI-647 P-A44 V-5PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FFm303.91303.9160.0FalseNoneNoneFalseNoneFalse18234.60
3387762119288NoneI-649 P-A44 V-5PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GFm495.6495.640.0FalseNoneNoneFalseNoneFalse19824.00
3387763119288NoneI-13.48 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GFm343.38343.3820.0FalseNoneNoneFalseNoneFalse6867.60
3387764119288NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GFNos154.58154.584.0FalseNoneNoneFalseNoneFalse618.320
3387765119288NoneI-37.28.1 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FFNos156.13156.134.0FalseNoneNoneFalseNoneFalse624.520
3387766119288NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GFNos185.26185.264.0FalseNoneNoneFalseNoneFalse741.040
3387767119288NoneI-37.28.2 S.R 2018-19Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FFNos187.11187.114.0FalseNoneNoneFalseNoneFalse748.440
3387768119288NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GFEach1201.241201.241.0FalseNoneNoneFalseNoneFalse1201.240
3387769119288NoneI-14.32.2 P-136 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FFEach1213.251213.251.0FalseNoneNoneFalseNoneFalse1213.250
3387770119288NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GFNos329.22329.221.0FalseNoneNoneFalseNoneFalse329.220
3387771119288NoneI-13.9.2 P-118 V-2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FFNos332.51332.511.0FalseNoneNoneFalseNoneFalse332.510
3387772119288NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GFNos6563.166563.161.0FalseNoneNoneFalseNoneFalse6563.160
3387773119288NoneI-14.22B P-135 V-2Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FFNos6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3387774119288NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GFNos585.28585.281.0FalseNoneNoneFalseNoneFalse585.280
3387775119288NoneI-14.40.2 P-137 V-2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FFNos591.13591.131.0FalseNoneNoneFalseNoneFalse591.130
3387776119288NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GFNos7052.867052.861.0FalseNoneNoneFalseNoneFalse7052.860
3387777119288NoneI-14.3.1 P-131 V-2Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FFNos7123.397123.391.0FalseNoneNoneFalseNoneFalse7123.390
3387778119288NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GFNos15422.615422.61.0FalseNoneNoneFalseNoneFalse15422.60
3387779119288NoneI-14.4.4 P-132 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FFNos15576.8315576.831.0FalseNoneNoneFalseNoneFalse15576.830
3387780119288NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GFNos5996.765996.762.0FalseNoneNoneFalseNoneFalse11993.520
3387781119288NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FFNos6056.736056.732.0FalseNoneNoneFalseNoneFalse12113.460
3387782119288NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GFm447.22447.2210.0FalseNoneNoneFalseNoneFalse4472.20
3387783119288NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FFm451.69451.6910.0FalseNoneNoneFalseNoneFalse4516.90
3387784119288NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GFm562.86562.8660.0FalseNoneNoneFalseNoneFalse33771.60
3387785119288NoneI-13.32.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FFm568.49568.4950.0FalseNoneNoneFalseNoneFalse28424.50
3387786119288NoneI-813 P-A36 V-2SS Bib cock with wall flange GFNos979.4979.45.0FalseNoneNoneFalseNoneFalse4897.00
3387787119288NoneI-813 P-A36 V-2SS Bib cock with wall flange FFNos989.19989.195.0FalseNoneNoneFalseNoneFalse4945.950
3387788119288NoneI-16.10 P-191 V-5Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc including the cost of CI frame and coverEach4998.484998.484.0FalseNoneNoneFalseNoneFalse19993.920
3387789119288NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l10.7310.732000.0FalseNoneNoneFalseNoneFalse21460.00
17194890720000NoneNoneBuildings7 CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NELLIGERE IN NAGAMANGALA TALUK OF MANDYA DISTRICT. (Electrical Works) (Slice-7)438375.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387790119289None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3387791119289None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3387792119289None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3387793119289None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3387794119289None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3387795119289None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3387796119289None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3387797119289None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3387798119289None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3387799119289None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3387800119289None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3387801119289None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3387802119289None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3387803119289None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3387804119289None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3387805119289None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3387806119289None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3387807119289None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3387808119289None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3387809119289None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3387810119289NoneI-1.13Supplyin and Fixing Metal Fan Box with Round Hook.No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3387811119289None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3387812119289None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3387813119289None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3387814119289None1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wallm34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3387815119289None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3387816119289None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3387817119289None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3387818119289None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3387819119289None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3387820119289None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3387821119289NoneI-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmmKm167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3387822119289None11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3387823119289None11.4.1Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3387824119289NoneI-6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3387825119289None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular modelEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3387826119289None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3387827119289NoneI-13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3387828119289NoneI-13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3387829119289None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsNo4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3387830119289None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3387831119289NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3387832119289None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3387833119289None5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Stripsm2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3387834119289None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3387835119289None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kAEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3387836119289None5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
3387837119289NoneI-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3387838119289NoneI-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3387839119289NoneI-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3387840119289NoneItemElectrical Deposite for Power SanctionLS35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194890730000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194890730000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194890730000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194890730000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194890730000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194890850000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17194890920000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17194890980000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17194891030000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17194891100000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17194891170000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17194891230000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17194891290000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17194891340000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17194891390000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17194891450000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17194891500000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17194891560000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17194891610000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17194891680000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17194891740000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17194891790000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17194891850000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17194891900000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17194891960000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.909.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.227.25 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 1659.00 Cum 2.PCC & RCC 1860.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 62.22 Tonnes 4.BBM/Concrete Blocks 337.00 Cum. 5. Flooring (Vitrified/Granite/Ceramic) 1453.00 Sqm 6. Plastering 5563.00 Sqm 7. Painting 5790.00 Sqm 8. MS Grill 2314.00 Sqm Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.15.35 Lakhs in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.9.74 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass II & Above PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished SlNo. Description of Key items of Works. Quantity1.Excavator/JCB 1No 2.Transit mixer/Concrete mixer 1 No 3.Needle vibrator with size not less than 20mm 1 No 4.Tipper 1 No 5.Generator 250 KVA 1 No 6. Truck Mounted Water Tanker 1 No Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 6 months .Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 5 years in the Construction of buildings OR Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.136.35 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST Category CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719489563000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone