createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719472892109
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd25000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-07-2024 16:00:00
tenderQueryClose08-07-2024 16:00:00
technicalBidOpen15-07-2024 11:00:00
publishedDate27-06-2024 16:27:41
publishedByPostRDPR_EE_DIV_YDG
publishedByUserKPE10677 - PRAKASH KULKARNI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPrakash Kulkarni
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448349742
tenderSupplierListNone
tenderSchedule
createdTs1719472892151
version8
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT6223
titleCONSTRUCTION OF PANCHAYATH BUILDING AT GUNDAGURTI VILLAGE IN WADAGERA TALUKA OF YADGIR DISTRICT.
descriptionCONSTRUCTION OF PANCHAYATH BUILDING AT GUNDAGURTI VILLAGE IN WADAGERA TALUKA OF YADGIR DISTRICT (ST Bidders Only)
categoryWORKS
categoryTextWorks
ecv2000000.00
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location971
locationNameRDPR Division Office Yadagiri
provisionalAmount2000000.0
groupOverheadTotal327969.16
fileNumberGP43
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194728920000NoneNoneBuildingsCONSTRUCTION OF PANCHAYATH BUILDING AT GUNDAGURTI VILLAGE IN WADAGERA TALUKA OF YADGIR DISTRICT.1672030.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3376330118899Nonecode01Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work 1.16.1 In Hard Rock ( requiring blasting) Depth upto 1.50m (PWD SR 2023-24 Volume-1 Item No. 1.16.1. p.No.09).Cum581.7581.750.805FalseNoneNoneFalseNoneFalse29553.26850
3376331118899Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).Cum6123.66123.67.353FalseNoneNoneFalseNoneFalse45026.83080
3376332118899Nonecode03Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).Cum6123.66123.68.658FalseNoneNoneFalseNoneFalse53018.12880
3376333118899Nonecode04Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).Cum6123.66123.65.681FalseNoneNoneFalseNoneFalse34788.17160
3376334118899Nonecode05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.3, p. No. 15).Cum6511.056511.0510.0957FalseNoneNoneFalseNoneFalse65733.6074850
3376335118899Nonecode06Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.6, p. No. 15).Cum6797.76797.70.2025FalseNoneNoneFalseNoneFalse1376.534250
3376336118899Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.5.1, p. No. 17).Cum7249.27249.29.1723FalseNoneNoneFalseNoneFalse66491.837160
3376337118899Nonecode08Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.1.1, p. No. 09).Cum5891.555891.5518.7897FalseNoneNoneFalseNoneFalse110700.4570350
3376338118899Nonecode09Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.4, p. No. 09).Cum6708.456708.4512.9397FalseNoneNoneFalseNoneFalse86805.3304650
3376339118899Nonecode10Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR, 2023-24, Volume-1 Item No. 1.11, p. No. 07).Cum454.65454.6528.9875FalseNoneNoneFalseNoneFalse13179.1668750
3376340118899Nonecode11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR, 2023-24, Volume-1 Item No. 1.11, p. No. 07).Cum454.65454.6514.4937FalseNoneNoneFalseNoneFalse6589.5607050
3376341118899Nonecode12Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge (PWD SR, 2023-24, Volume-2 Item No. 6.1, p. No. 13).Cum8631.08631.020.5309FalseNoneNoneFalseNoneFalse177202.19790
3376342118899Nonecode13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR, 2023-24, Volume-2 Item No. 6.12, p. No. 14).Sqm1053.151053.157.554FalseNoneNoneFalseNoneFalse7955.49510
3376343118899Nonecode14Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges completeas per specifications. (PWD SR, 2023-24, Volume-2 Item No. 12.12, p. No. 99).Cum130412.1130412.10.621FalseNoneNoneFalseNoneFalse80985.91410
3376344118899Nonecode15Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR, 2023-24, Volume-2 Item No. 12.21, p. No. 100).Sqm6029.16029.16.615FalseNoneNoneFalseNoneFalse39882.49650
3376345118899Nonecode16Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (PWD SR, 2023-24, Volume-2 Item No. 12.15, p. No. 100).Sqm7241.857241.859.0FalseNoneNoneFalseNoneFalse65176.650
3376346118899Nonecode17Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (PWD SR, 2023-24, Volume-2 Item No. 11.34A, p. No. 86).Kgs176.4176.4217.35FalseNoneNoneFalseNoneFalse38340.540
3376347118899Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (PWD SR, 2023-24, Volume-2 Item No. 11.54, p. No. 104).Sqm333.9333.91.35FalseNoneNoneFalseNoneFalse450.7650
3376348118899Nonecode19Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.3.2, P.No. 41).Sqm349.65349.6518.96FalseNoneNoneFalseNoneFalse6629.3640
3376349118899Nonecode20Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.1.1, P.No. 14).Sqm267.75267.7548.3126FalseNoneNoneFalseNoneFalse12935.698650
3376350118899Nonecode21Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 , Volume-2 Item No. 8.2.1,P.No. 41).Sqm309.75309.75164.595FalseNoneNoneFalseNoneFalse50983.301250
3376351118899Nonecode22Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 , Volume-2 Item No. 8.24,P.No. 45).Sqm113.4113.4231.8676FalseNoneNoneFalseNoneFalse26293.785840
3376352118899Nonecode23Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.33.2, P.No. 46).Sqm144.9144.933.21FalseNoneNoneFalseNoneFalse4812.1290
3376353118899Nonecode24Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).Cum6123.66123.63.8859FalseNoneNoneFalseNoneFalse23795.697240
3376354118899Nonecode25Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).9.21.1 Size of Tile 500x500 mm (PWD SR 2023-24 ,Volume-2, Item No. 9.21.1, P.No. 62).Sqm1234.81234.851.8126FalseNoneNoneFalseNoneFalse63978.198480
3376355118899Nonecode26Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR 2023-24 ,Volume-2, Item No. 9.39, P.No. 63).Sqm1521.451521.451.44FalseNoneNoneFalseNoneFalse2190.8880
3376356118899Nonecode27Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR 2023-24 ,Volume-2, Item No. 9.39, P.No. 63).Sqm1521.451521.454.86FalseNoneNoneFalseNoneFalse7394.2470
3376357118899Nonecode28Providing structural steel for sub-structure complete as per drawing and technical specification (PWD SR, 2023-24, Volume-3 Item No. 12.12, p. No. 118).Tonne176128.05176128.052.654FalseNoneNoneFalseNoneFalse467443.84470
3376358118899Nonecode29Providing and fixing white vitreous china water closet squatting pan (Indian type) : 14.13.1 Long pattern W.C. pan of size 580 mm (PWD SR 2023-24 ,Volume-2, Item No. 14.13.1, P.No. 134).Nos1499.41499.41.0FalseNoneNoneFalseNoneFalse1499.40
3376359118899Nonecode30Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia, 6.0 kg/sqcm & class 3 (PWD SR 2023-24 Volume-5 Item No. 10.1.7. p.No.117).Mtr431.55431.556.0FalseNoneNoneFalseNoneFalse2589.30
3376360118899Nonecode31CONSTRUCTION OF SEPTIC TANK Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work 1.16.1 In Hard Rock ( requiring blasting) Depth upto 1.50m (PWD SR 2023-24 Volume-1 Item No. 1.16.1. p.No.09).Cum581.7581.76.2352FalseNoneNoneFalseNoneFalse3627.015840
3376361118899Nonecode32Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 (PWD SR 2023-24 Volume-2 Item No. 13.53. p.No.126).Cum5924.15924.11.0FalseNoneNoneFalseNoneFalse5924.10
3376362118899Nonecode33Supply and fixing 900 mm dia. NP-2 Collars, 6 Nos. with top covers including transportation to site, lead and lift, cost of materials. Labour, curing and refilling the Sides of Septic Tank etc. completed as per direction incharge of site engineer. Market RateCum6300.06300.01.0FalseNoneNoneFalseNoneFalse6300.00
3376363118899Nonecode34Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 (PWD SR, 2023-24, Volume-3 Item No. 8.54, p. No.78)Nos9450.09450.01.0FalseNoneNoneFalseNoneFalse9450.00
3376364118899Nonecode35ELELECTRICAL Open Conduit System: Supplying heavy gauge PVC conduit pipedia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc and fixing using inverted wook boxes in case of RCC ceiling and RCC wall stone structure or raw plugs in case of brick wall and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws (PWD DSR 2019-20, I. No.1.1, P.No.2) 25 mm dia. 2mm thickMtr175.0175.012.0FalseNoneNoneFalseNoneFalse2100.00
3376365118899Nonecode36Supplying heavy gauge PVC Conduit Pipe ....... dia .....mm thick suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG G fish wire run throughout the conduit wherever necessary (PWD DSR 2019-20, I. No. 1.3b, P.No.2) 25 mm dia. 2mm thickMtr54.054.030.0FalseNoneNoneFalseNoneFalse1620.00
3376366118899Nonecode37Supplying heavy gauge PVC Conduit Pipe ....... dia .....mm thick suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG G fish wire run throughout the conduit wherever necessary (PWD DSR 2019-20, I. No. 1.3b, P.No.2) 32 mm dia. 2.5 mm thickMtr81.081.024.0FalseNoneNoneFalseNoneFalse1944.00
3376367118899Nonecode38Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5) a) Short Point upto 3 Meters long from tapping point to out let via. switch. (PWD DSR 2019-20, I.No.2.1.1, P.No.5)Mtr200.0200.03.0FalseNoneNoneFalseNoneFalse600.00
3376368118899Nonecode39Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5) b) Short Point upto 3 Meters long from tapping point to out let via. switch. (PWD DSR 2019-20, I. No.2.1.2, P.No.5Mtr275.0275.06.0FalseNoneNoneFalseNoneFalse1650.00
3376369118899Nonecode40Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5) c) Medium Point above 6 Mtrs to 10 mtrs. from tapping point to out let via. switch. (PWD DSR 2019-20, I.No.2.1.3), P.No.5Mtr400.0400.02.0FalseNoneNoneFalseNoneFalse800.00
3376370118899Nonecode41Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood after due groove cutting, finishing with necessary cement plastering complete (PWD DSR 2019-20, 1.No.1.6, P.No.3) 8"x6"x3"Point64.064.03.0FalseNoneNoneFalseNoneFalse192.00
3376371118899Nonecode42Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood after due groove cutting, finishing with necessary cement plastering complete (PWD DSR 2019-20, 1.No.1.6, P.No.3) 4"x4"x3"Point60.060.04.0FalseNoneNoneFalseNoneFalse240.00
3376372118899Nonecode43Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6) a) 1.5 sqmm. (PWD DSR 2019-20, 1, No. 2.3.2, P.No.5-6)Point20.520.5100.0FalseNoneNoneFalseNoneFalse2050.00
3376373118899Nonecode44Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6) b) 2.5 sqmm. (PWD DSR 2019-20, L.No.2.3.3, P.No.6)Point35.035.0120.0FalseNoneNoneFalseNoneFalse4200.00
3376374118899Nonecode45Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6) c) 4.0 sqmm. (PWD DSR 2019-20, 1.No.2.3.4, P.No.6)Point45.045.065.0FalseNoneNoneFalseNoneFalse2925.00
3376375118899Nonecode46Supplying and fixing Regular MCB distribution boards on wall board flush mounting using required clamps bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting made out of 14 SWG MS enclouse a) 12 Way SP (PWD DSR 2019-20, I. No.5.18.8, P.No.28)Point1800.01800.01.0FalseNoneNoneFalseNoneFalse1800.00
3376376118899Nonecode47Supplying and fixing Regular MCB distribution boards on wall board flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting made out of 14 SWG MS enclouse b) 4 Way SPPoint1100.01100.02.0FalseNoneNoneFalseNoneFalse2200.00
3376377118899Nonecode48Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with Short Circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD DSR 2019-20, 1.No.5.17.1, P.No.27) a) 6-2 Amps SPEach434.0434.03.0FalseNoneNoneFalseNoneFalse1302.00
3376378118899Nonecode49Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with Short Circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD DSR 2019-20, 1.No.5.17.1, P.No.27) b) 50-63 Amps DPEach1355.01355.01.0FalseNoneNoneFalseNoneFalse1355.00
3376379118899Nonecode50LED Indoor Supply of 2' feet LED PVC Square Batten W with high quality diffuser with life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power input: 220-240V 50Hz Power factor 0.9 along with CE approved drivers. 5 years warranty against any manufacturing defect working under standard electrical condition (PWD DSR 2019-20, 1.No. 12.3.4, P.No.) LED Light Fitting 1x4' 20/22WEach375.0375.010.0FalseNoneNoneFalseNoneFalse3750.00
3376380118899Nonecode51Supply capacitor type ceiling fan complete with down rod blades, shakle regulator canopies etc. for operation on 230 volts, 50 cycles, single phase AC supply confirming to ISS 374-1979 and with bouble ball bearing system - 48" Sweep (1200 mm) (PWD DSR 2019-20, I.No.7.3, P.No.46)Mtr2090.02090.02.0FalseNoneNoneFalseNoneFalse4180.00
3376381118899Nonecode52Supply of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC supply 12" Sweep 300mm (PWD DSR 2019-20, I.No.7.2.1, P.No.46)Mtr2100.02100.01.0FalseNoneNoneFalseNoneFalse2100.00
3376382118899Nonecode53Supply and fixing PBBC Bakelite straight or slant batten holder and wiring with 60W 230 Volts Clamps PBBC Bakelite Straight etc. completed (PWD DSR 2019-20, 1. No.4.2, P.No.20)Mtr88.088.06.0FalseNoneNoneFalseNoneFalse528.00
3376383118899Nonecode54Supply, fixing and wiring Electronic Trivector Meter (ETC)5 to 20 amps single phase Class-1 Accurcy with Temple Proof Energy Meter et. completed (PWD DSR 2019-20, I.No.5.30, P.No.29)Each1150.01150.01.0FalseNoneNoneFalseNoneFalse1150.00
3376384118899Nonecode55Supply and fixing of .... Mm dia: Class-A GI Pipe bracket up to 2 Mirs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts flourescent tube street light fitting of all capacities to GI and CI or Rail or RCC pole / wall using suitable clamps and bolts and wiring using suitable capacity wires (PWD DSR 2019-20, I.No. 14.1, P. No.79) Using 32mm dia. Gt PipeEach835.0835.01.0FalseNoneNoneFalseNoneFalse835.00
3376385118899Nonecode56Fixing of all types and all capacities flourescent / false ceiling/ spot light/CFL/LED fittings Indoor on the wall / Ceiling/ rafters/ girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps if required On wall / ceiling/rafter/ girders (PWD DSR 2019-20, I.No. 14.7.1, P. No.79)Each110.0110.06.0FalseNoneNoneFalseNoneFalse660.00
3376386118899Nonecode57Fixing of ceiling / wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board with supplying and fixing a 5 ampes ceiling rose necessary length of 23/0.0076' PVC insulated twin twisted copper wire and wiring - Fixing a Ceiling (PWD DSR 2019-20, I.No.14.8, P.No.80)Each150.0150.02.0FalseNoneNoneFalseNoneFalse300.00
3376387118899Nonecode58Fixing One Exhaust Fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient lenght of of 23/0.0076' PVC insulated twin core wire - Exhaust Fan (PWD DSR 2019-20, 1. No. 14.12, P.No.80)Each400.0400.01.0FalseNoneNoneFalseNoneFalse400.00
3376388118899Nonecode59Fixing halogen / metal hallide / SVL/IL/ LED flood light fitting over existing pole wall including clamps bolts nuts and wiring using suitable capacity wire etc. completed Fixing Halogen / Metal Halide SVL Flood Light (PWD DSR 2019-20, 1. No. 14.5, P. No.79)Each175.0175.03.0FalseNoneNoneFalseNoneFalse525.00
3376389118899Nonecode60Supplying and fixing hylum plastic sheet 3mm thick with necessary nitiches for fixing switches, regulators etc, and fixing on existing wood or metal box using N.F.screws etc. completed (PWD DSR 2019-20, L.No.3.9, P.No. 10)Mtr0.240.24825.0FalseNoneNoneFalseNoneFalse198.00
3376390118899Nonecode61Supplying and fixing angle iron frame work fabricated out of M.S angle iron..and M.S flat... with bolts, washers etc, and painted with 2 coats of red oxide and then two coats of approved paint - 40x40x6mm etc. completed (PWD DSR 2019-20, 1.No.5.41.1, P.No.30)Mtr255.0255.01.0FalseNoneNoneFalseNoneFalse255.00
3376391118899Nonecode62Supplying, fixing, wiring, earth electrode for grounding conduits I.C cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick G.I pipe 2.5mtr long buried in a pit..The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. using 12mm dia bolts, nuts, washers and check nuts etc. the pipe shall have 16 through holes of 12mm dia etc. completed (PWD DSR 2019-20, 1.No.6, P.No.40)Each2999.72999.71.0FalseNoneNoneFalseNoneFalse2999.70
3376392118899Nonecode63Supplying and running GI/ Copper conductor for grounding and along with other wires in conduit system of wiring using necessary suitable size clamps, nailsm guttas spacers etc-8 SWG Gl wire etc. completed (PWD DSR 2019-20, 1.No.6.18.1, P.No.43)Mtr14.014.06.0FalseNoneNoneFalseNoneFalse84.00
3376393118899Nonecode64Supplying and fixing of class A (medium duty) GI Pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangments for UG cale of 1.1 k 40mm etc. completed (PWD DSR 2019-20, I.No.6.9.1, P.No.41)Mtr355.0355.06.0FalseNoneNoneFalseNoneFalse2130.00
3376394118899Nonecode65Labour charges for logging UG cable 6 sqmm to 16 sqmm (PWD DSR 2019-20, 1.No.7.2.1, P.No.46)Mtr11.8811.8815.0FalseNoneNoneFalseNoneFalse178.20
3376395118899Nonecode66Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable Part- 1. Amouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975- 2Core 10 SqmmMtr95.095.010.0FalseNoneNoneFalseNoneFalse950.00
3376396118899Nonecode67Supply and laying double walled corrugated (DWC) HDPE Pipe including all neceassary connecting sockets couplings/ Teels /Bends/ End caps of same materials in existing trench -63mm dia OD50mm ID etc. completed 2 core 10 sqmm (PWD DSR 2019- 20, 1.No.7.20, P.No.63)Mtr206.0206.010.0FalseNoneNoneFalseNoneFalse2060.00
3376397118899Nonecode68Supplying and fixing cut out 16 amps (PWD DSR 2019-20, 1.No.5.7, P.No.24)Each117.0117.02.0FalseNoneNoneFalseNoneFalse234.00
3376398118899Nonecode69Supplyng and fixing of 4 pole powder contractor 40 ampsEach1840.01840.01.0FalseNoneNoneFalseNoneFalse1840.00
3376399118899Nonecode70Supplying of TPST with rewireable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour (PWD DSR 2019-20, 1.No.5.5.1, P.No.24)Each1800.01800.01.0FalseNoneNoneFalseNoneFalse1800.00
3376400118899Nonecode71Supplying 6A flush type socket and 6 amps flush type SP switch either surface/ flush mounting in exisiting gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654-9-6 amps 3/5 way etc. completed (PWD DSR 2019-20, 1.No.3.1.2, P.No.9)Each132.0132.06.0FalseNoneNoneFalseNoneFalse792.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194728940000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194728940000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194728940000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194728940000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194728940000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneWork Done certificate by not below rank of Executive EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer shall have valid class -IV KPWD LicenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAnnual financial turnover certificated from C.A. on Letter Head with UDIN No. otherwise bid will be directly disqualifiedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReserved Category CertificateOthersReserved Category Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Reserved Category Certificate
NoneNoneNoneNoneother documentsOthersother documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- other documents
NoneNoneNoneNonePhone number and Address Letter padOthersPhone number and Address Letter pad
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Phone number and Address Letter pad
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateTrueTechnical Bid
Work Done Certificate from authority not below the rank of Executive Engineer or equivalenTrueTechnical Bid
Other DocumentsTrueTechnical Bid
letter pad with mobile noTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsYadgirShahapuraRaichurRAICHURGUNDAGURTINoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone