tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719560520000 | 0 | None | None | Roads | PROVIDING AND FIXING INTER LOCK PAVERS ,STREET LIGHT AND CONSTRUCTION OF C C DRAIN , FOOTPATH FROM BASAVESHWAR CIRCLE TO JIDGA LAKE IN JIDGA VILLAGE IN ALAND TALUKA KALABURGI DISTRICT .(CONSTRUCTION OF ROAD ) | 28838216.57 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3395115 | 119686 | None | P.No-8, I.No-1.12 SR for Roads & Bridges Vol-I 20 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 99.75 | 99.75 | 2840.08 | False | None | None | False | None | False | 283297.98 | 0 | 3395116 | 119686 | None | P.No-7, I.No-1.7 Uni SR Vo-1 2023-24 | Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction.(Royalty shall be recovered @60/m3 )
| Cum | 124.95 | 124.95 | 852.02 | False | None | None | False | None | False | 106459.899 | 0 | 3395117 | 119686 | None | P.No-7, I.No-1.8 Uni SR Vo-1 2023-24 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 497.7 | 497.7 | 915.59 | False | None | None | False | None | False | 455689.143 | 0 | 3395118 | 119686 | None | P.No-17, I.No-3.6 SR for Roads & Bridges Vol-III | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
| Cum | 517.65 | 517.65 | 3236.0 | False | None | None | False | None | False | 1675115.4 | 0 | 3395119 | 119686 | None | P.No-51, I.No-6.8.2 SR for Roads & Bridges Vol-II | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as
per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) | Sqm | 1219.05 | 1219.05 | 16558.0 | False | None | None | False | None | False | 20185029.9 | 0 | 3395120 | 119686 | None | P.No-65, I.No-8.7 SR for Roads & Bridges Vol-III | Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing
| Sqm | 9460.5 | 9460.5 | 3.0 | False | None | None | False | None | False | 28381.5 | 0 | 3395121 | 119686 | None | P.No-64, I.No-8.6-A-iv SR for Roads & Bridges Vol | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class C Type XI retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022.
60 cm equilateral triangle | Sqm | 3784.2 | 3784.2 | 5.88 | False | None | None | False | None | False | 22251.096 | 0 | 3395122 | 119686 | None | P.No-63, I.No-8.1-a SR for Roads & Bridges Vol-II | Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409
| m | 250.95 | 250.95 | 3028.0 | False | None | None | False | None | False | 759876.6 | 0 | 3395123 | 119686 | None | P.No-64, I.No-9.31 SR for Roads & Bridges Vol-II | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications.
| Sqm | 1141.35 | 1141.35 | 4663.0 | False | None | None | False | None | False | 5322115.05 | 0 |
| 1719560520000 | 0 | None | None | Roads | PROVIDING AND FIXING INTER LOCK PAVERS ,STREET LIGHT AND CONSTRUCTION OF C C DRAIN , FOOTPATH FROM BASAVESHWAR CIRCLE TO JIDGA LAKE IN JIDGA VILLAGE IN ALAND TALUKA KALABURGI DISTRICT .( CONSTRUCTION OF CC DRAIN ) | 6199556.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3395124 | 119687 | None | P.No-8, I.No-1.14.1 Uni SR Vo-1 2023-24 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work
| Cum | 107.1 | 107.1 | 1135.44 | False | None | None | False | None | False | 121605.624 | 0 | 3395125 | 119687 | None | P.No-15, I.No-2.1.3 Uni SR Vo-1 2023-24 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 141.93 | False | None | None | False | None | False | 892519.7085 | 0 | 3395126 | 119687 | None | P.No-16, I.No-2.4.1 Uni SR Vo-1 2023-24 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7262.14 | 7262.14 | 454.18 | False | None | None | False | None | False | 3298318.7452 | 0 | 3395127 | 119687 | None | P.No-18, I.No-2.11 Uni SR Vo-1 2023-24 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 90754.65 | 90754.65 | 19.14 | False | None | None | False | None | False | 1737044.001 | 0 | 3395128 | 119687 | None | P.No-117, I.No-12.2 Uni SR Vol-3 2023-24 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2 , extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
| No | 250.95 | 250.95 | 598.0 | False | None | None | False | None | False | 150068.1 | 0 |
| 1719560520000 | 0 | None | None | Roads | PROVIDING AND FIXING INTER LOCK PAVERS ,STREET LIGHT AND CONSTRUCTION OF C C DRAIN , FOOTPATH FROM BASAVESHWAR CIRCLE TO JIDGA LAKE IN JIDGA VILLAGE IN ALAND TALUKA KALABURGI DISTRICT .(STREET LIGHT ESTIMATE ) | 7318650.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3395129 | 119688 | None | 2023-24 | Decorative light poles Fabricating. supplying and erection of 1I Mtrs long hot dip Gialvanized Conical pole with BSEN 10025 grade S 355 JO steel plate for shaft, 1IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet for MCBs as per IS specifications suitable to
withstand the wind specd of 47 m Per sec for 11 Mirs pole in double single section and single joint welded per IS 9505 18s 1o178AWS having dimensions bottom 200nmm, top 70 mm with 3mm thick, 2no sof pole The poles should be painted acsthetically using good quality PU auto coat paint. The centre pole should be 3mtr hevght 16smm dia 3mm thick hav ing Imtr perforation from 1 Smtr to 2.Smtr height the poy carbonate pipe housed inside the perforation along with color changing LED visible from all side. The foundation plate should be suitable to fix 2nos of 11 mtr bent at side of this pole. The suitable aluminum head placed at top including PC cover having 7watt LELD Bulb inside suitable base plate and ono s ot M 4m longBolts along wth template and necessary arrangements. The pole shallbe Hot dip galvanized in singie dipping with not less than 65 micron as per ASTM-A 123 and 153 etc. EOl approved rate. The pole should be as shown in attached picture | Each | 86578.0 | 86578.0 | 20.0 | False | None | None | False | None | False | 1731560.0 | 0 | 3395130 | 119688 | None | CSR(2023-24) I.No. 66.04 | HDPE/PLB Pipe 50/42 mm (11KV SYSTEM MATERIAL)
| Km | 85014.0 | 85014.0 | 1.0 | False | None | None | False | None | False | 85014.0 | 0 | 3395131 | 119688 | None | 2023-2024 Vol No.1, Page No:8, Item No: 1.14.1 | Mechanical Means: -In all kinds of soils Depth upto 3m Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | Cum | 102.0 | 102.0 | 45.0 | False | None | None | False | None | False | 4590.0 | 0 | 3395132 | 119688 | None | 2023-2024 Vol No.1, Page No:17, Item No:2.4.1 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6404.0 | 6404.0 | 6.75 | False | None | None | False | None | False | 43227.0 | 0 | 3395133 | 119688 | None | 2023-2024 Vol No.1, Page No:15, Item No:2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6287.0 | 6287.0 | 16.575 | False | None | None | False | None | False | 104207.025 | 0 | 3395134 | 119688 | None | 2023-2024 Vol No.1, Page No:18, Item No:2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 86433.0 | 86433.0 | 1.6575 | False | None | None | False | None | False | 143262.6975 | 0 | 3395135 | 119688 | None | CSR(2023-24) I.No.32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 4 core 16sqmm (11KV SYSTEM MATERIAL) | Km | 141842.0 | 141842.0 | 4.0 | False | None | None | False | None | False | 567368.0 | 0 | 3395136 | 119688 | None | CSR(2023-24) I.No.32.07 | b) 3.5 core 25sqmm
(11KV SYSTEM MATERIAL) | Km | 139549.0 | 139549.0 | 0.375 | False | None | None | False | None | False | 52330.875 | 0 | 3395137 | 119688 | None | CSR(2021-22) I.No.31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
a) 2.5 to 25 Sqmm
(11kv labour )
| Km | 11.88 | 11.88 | 3.25 | False | None | None | False | None | False | 38.61 | 0 | 3395138 | 119688 | None | CSR(2021-22) I.No.31.05 | b)2.5 to 25 Sqmm (11kv labour ) | Km | 15.5 | 15.5 | 0.375 | False | None | None | False | None | False | 5.8125 | 0 | 3395139 | 119688 | None | PWDSR(2019-20) page No-41 I.No.6.6.1 | Digging of trench of 0.6 m deepx 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete. As per civil SR KSRB 1-2 p-7
a) In ordinary soil
| Mtr | 76.0 | 76.0 | 2400.0 | False | None | None | False | None | False | 182400.0 | 0 | 3395140 | 119688 | None | PWDSR(2019-20) page No-41 I.No.6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable.
| Mtr | 100.0 | 100.0 | 2400.0 | False | None | None | False | None | False | 240000.0 | 0 | 3395141 | 119688 | None | CSR(2021-22) I.No.49.04 | GI Pipe B - Class as per IS-1239
a) 40mm | Mtr | 295.0 | 295.0 | 250.0 | False | None | None | False | None | False | 73750.0 | 0 | 3395142 | 119688 | None | CSR(2021-22) I.No.49.07 | b) 65mm
| Mtr | 547.0 | 547.0 | 125.0 | False | None | None | False | None | False | 68375.0 | 0 | 3395143 | 119688 | None | PWDSR(2019-20) page No-42 I.No70.01 | Brass Cable Gland
a) 25mm dia
| Each | 77.0 | 77.0 | 200.0 | False | None | None | False | None | False | 15400.0 | 0 | 3395144 | 119688 | None | CSR (2021-22) I.no.64.02 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the follwing sizes
a) 16sqmm | Each | 3.0 | 3.0 | 1250.0 | False | None | None | False | None | False | 3750.0 | 0 | 3395145 | 119688 | None | CSR (2021-22) I.no.64.03 | b) 25sqmmlong barrel | Each | 4.0 | 4.0 | 200.0 | False | None | None | False | None | False | 800.0 | 0 | 3395146 | 119688 | None | PWD SR(2019-20) P.no.40 I.no. 6.3.1 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip. | Mtr | 75.0 | 75.0 | 5500.0 | False | None | None | False | None | False | 412500.0 | 0 | 3395147 | 119688 | None | CSR(2021-22) I.no.5.6.6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted
wooden plugs screws 20"" x 20"" x 2.5"
| Each | 315.0 | 315.0 | 7.5 | False | None | None | False | None | False | 2362.5 | 0 | 3395148 | 119688 | None | PWD SR(2021-22) I.no. 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. | Sq CM | 0.26 | 0.26 | 20000.0 | False | None | None | False | None | False | 5200.0 | 0 | 3395149 | 119688 | None | CSR(2021-22) I.No.5.42.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG
| Sq CM | 0.43 | 0.43 | 625000.0 | False | None | None | False | None | False | 268750.0 | 0 | 3395150 | 119688 | None | CSR(2021-22) I.No.5.13.3 | Supplying and fixing of 4 pole power contractor with NO/NC contacts on existing wood /panel board using necessary bolts,nuts,washers and wiring etc., complete with AC 3 rating and as per IS-13947
60-70Amps
| Each | 4926.0 | 4926.0 | 7.5 | False | None | None | False | None | False | 36945.0 | 0 | 3395151 | 119688 | None | CSR(2021-22) I.No.5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.
| Each | 5125.0 | 5125.0 | 7.5 | False | None | None | False | None | False | 38437.5 | 0 | 3395152 | 119688 | None | CSR(2021-22 I.No.5.47 | Supplying and fixing microprocessor based electronic timer(without contact ,Din mounting using necessary bolts,nuts and washers etc.,)3-120sec
| Each | 2079.0 | 2079.0 | 7.5 | False | None | None | False | None | False | 15592.5 | 0 | 3395153 | 119688 | None | CSR(2021-22) I.No.5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
a) 6-32 Amps SP
| Each | 523.0 | 523.0 | 125.0 | False | None | None | False | None | False | 65375.0 | 0 | 3395154 | 119688 | None | CSR(2021-22) I.No.5.17.9 | b) 50-63Amps TPN
| Each | 2399.0 | 2399.0 | 5.0 | False | None | None | False | None | False | 11995.0 | 0 | 3395155 | 119688 | None | CSR(2021-22) I.No.5.20.4 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.63amps 4 pole | Each | 3058.0 | 3058.0 | 7.5 | False | None | None | False | None | False | 22935.0 | 0 | 3395156 | 119688 | None | CSR(2021-22) I.No.5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron and M.S flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
| Mtr | 275.0 | 275.0 | 125.0 | False | None | None | False | None | False | 34375.0 | 0 | 3395157 | 119688 | None | CSR(2021-22) I.No.2.5.7 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 2C x 2.5sq.mm
| Mtr | 79.0 | 79.0 | 2250.0 | False | None | None | False | None | False | 177750.0 | 0 | 3395158 | 119688 | None | CSR(2021-22) item no 1.3.3 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thick
| Mtr | 105.0 | 105.0 | 250.0 | False | None | None | False | None | False | 26250.0 | 0 | 3395159 | 119688 | None | PWDSR(2019-20) page No-40 I.No.6.1 | Supplying , fixing, wiring, earth electrode for grounding conduits, I.C cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit…. The pit should be filled with equal proportion of salt and hcarcoal 150 mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through GI pipe of sizw as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.
| No | 2999.7 | 2999.7 | 37.5 | False | None | None | False | None | False | 112488.75 | 0 | 3395160 | 119688 | None | CSR(2021-22) I.No.5.7.4 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and washers 100Amps
| No | 650.0 | 650.0 | 30.0 | False | None | None | False | None | False | 19500.0 | 0 | 3395161 | 119688 | None | CSR(2021-220) I.No5.8.3 | Supplying of switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947 125 Amps
| Each | 5292.0 | 5292.0 | 7.5 | False | None | None | False | None | False | 39690.0 | 0 | 3395162 | 119688 | None | CSR(2021-220) I.No.5.38 | Supplying and fixing LED type panel board indicating lamp with required colour suitable for 220v A.C 50 Hz 12/24v D.C
| No | 464.0 | 464.0 | 22.5 | False | None | None | False | None | False | 10440.0 | 0 | 3395163 | 119688 | None | CSR(2021-22) I.No.5.25 | Supplying ,fixing and wiring 0 to 100 amps direct reading AC analog type Ammeter
| Each | 472.0 | 472.0 | 7.5 | False | None | None | False | None | False | 3540.0 | 0 | 3395164 | 119688 | None | CSR(2021-22) item no 1.9.2 | Supplying PVC/GI flexible conduit pipe 25 mm dia fixing on furface over inverted taperd wooden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles at an interval of 300mm using NF screws and on either and of the pipe terminated completely.25mm
| Mtr | 31.0 | 31.0 | 125.0 | False | None | None | False | None | False | 3875.0 | 0 | 3395165 | 119688 | None | CSR(2021-22) I.No.5.22 | Supplying fixing and wiring 0 to 600 volts 96x96mm AC voltmeter on existing panel/wood board.
| Each | 407.0 | 407.0 | 7.5 | False | None | None | False | None | False | 3052.5 | 0 | 3395166 | 119688 | None | CSR(2021-22) I.No.5.40.1 | Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminium Strips
| Mtr | 2214.0 | 2214.0 | 20.0 | False | None | None | False | None | False | 44280.0 | 0 | 3395167 | 119688 | None | CSR(2021-22) I.No.5.14.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE 100Amps 25kA.
| Each | 8265.0 | 8265.0 | 7.5 | False | None | None | False | None | False | 61987.5 | 0 | 3395168 | 119688 | None | CSR(2021-22) I.No. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm
| Mtr | 40.0 | 40.0 | 1250.0 | False | None | None | False | None | False | 50000.0 | 0 | 3395169 | 119688 | None | CSR(2021-22) I.No. 11.7.2 | LED Post Top Lantern GARDEN. :Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
LED Post Top Lantern with 35 W | No | 7912.0 | 7912.0 | 75.0 | False | None | None | False | None | False | 593400.0 | 0 | 3395170 | 119688 | None | CSR(2021-22) I.No. 4.3 | Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75 mm outer dia and 7 feet height top piece outer dia of 65 mm fixed by measure of threading/welding/coupling complete. (excluding foundation).
| No | 18603.0 | 18603.0 | 75.0 | False | None | None | False | None | False | 1395225.0 | 0 | 3395171 | 119688 | None | CSR(2021-22) I.No. 11.8.3 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect
LED Streetlight 70W | No | 5955.0 | 5955.0 | 75.0 | False | None | None | False | None | False | 446625.0 | 0 | 3395172 | 119688 | None | 2023-24 | GESCOM Deposit and departmental charges, third party charges and others (may be paid as per actual) Rs
| Rs | 100000.0 | 100000.0 | 1.0 | False | None | None | False | None | False | 100000.0 | 0 |
|
|
---|