| 3384033 | 119187 | None | GKVK01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mehanical means using dozer In area of light jungle | 100 Sqm | 393.0 | 393.0 | 9.0 | False | None | None | False | None | False | 3537.0 | 0 |
| 3384034 | 119187 | None | GKVK02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth VOL1 | Cum | 95.0 | 95.0 | 270.0 | False | None | None | False | None | False | 25650.0 | 0 |
| 3384035 | 119187 | None | GKVK03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 102.0 | 102.0 | 410.0 | False | None | None | False | None | False | 41820.0 | 0 |
| 3384036 | 119187 | None | GKVK04 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 242.0 | 242.0 | 140.0 | False | None | None | False | None | False | 33880.0 | 0 |
| 3384037 | 119187 | None | GKVK05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | Cum | 266.0 | 266.0 | 220.0 | False | None | None | False | None | False | 58520.0 | 0 |
| 3384038 | 119187 | None | GKVK06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 474.0 | 474.0 | 294.0 | False | None | None | False | None | False | 139356.0 | 0 |
| 3384039 | 119187 | None | GKVK07 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C./ Lindale 20%E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labor, usage charges of machinery, complete as per specifications. | Sqm | 118.0 | 118.0 | 537.0 | False | None | None | False | None | False | 63366.0 | 0 |
| 3384040 | 119187 | None | GKVK08 | Providing and laying in position cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Including Formwork,centering and scaffolding. Mix 1:4:8 Using 40 mm nominal sizes graded crushed coarseaggregates . | Cum | 5664.0 | 5664.0 | 96.0 | False | None | None | False | None | False | 543744.0 | 0 |
| 3384041 | 119187 | None | GKVK09 | Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Including Formwork,centering and scaffolding. Mix 1:3:6 Using 20 mm nominal sizes graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 24.0 | False | None | None | False | None | False | 149208.0 | 0 |
| 3384042 | 119187 | None | GKVK10 | do: FF | Cum | 6279.17 | 6279.17 | 12.5 | False | None | None | False | None | False | 78489.625 | 0 |
| 3384043 | 119187 | None | GKVK11 | do: terrace floor | Cum | 6341.34 | 6341.34 | 1.2 | False | None | None | False | None | False | 7609.608 | 0 |
| 3384044 | 119187 | None | GKVK12 | Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2037.17 | 2037.17 | 72.68 | False | None | None | False | None | False | 148061.5156 | 0 |
| 3384045 | 119187 | None | GKVK13 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.Including Formwork,centering and scaffolding M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate . | Cum | 6842.88 | 6842.88 | 66.5 | False | None | None | False | None | False | 455051.52 | 0 |
| 3384046 | 119187 | None | GKVK14 | do: Column upto plinth top | Cum | 10771.2 | 10771.2 | 10.0 | False | None | None | False | None | False | 107712.0 | 0 |
| 3384047 | 119187 | None | GKVK15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Including Formwork,centering and scaffolding M25 design mix using nominal size graded crushed coarse aggregate Ground Floor. 1. Plinth Beam | Cum | 10264.5 | 10264.5 | 16.5 | False | None | None | False | None | False | 169364.25 | 0 |
| 3384048 | 119187 | None | GKVK16 | do: Column upto Roof bottom | Cum | 11633.1 | 11633.1 | 14.0 | False | None | None | False | None | False | 162863.4 | 0 |
| 3384049 | 119187 | None | GKVK17 | do: Chajja | Cum | 9922.35 | 9922.35 | 2.5 | False | None | None | False | None | False | 24805.875 | 0 |
| 3384050 | 119187 | None | GKVK18 | do: Roof Beam & Lintel | Cum | 10948.8 | 10948.8 | 43.0 | False | None | None | False | None | False | 470798.4 | 0 |
| 3384051 | 119187 | None | GKVK19 | do: Roof Slab | Cum | 10264.5 | 10264.5 | 82.0 | False | None | None | False | None | False | 841689.0 | 0 |
| 3384052 | 119187 | None | GKVK20 | StairCase | Cum | 10264.5 | 10264.5 | 5.0 | False | None | None | False | None | False | 51322.5 | 0 |
| 3384053 | 119187 | None | GKVK21 | First Floor, Column upto Roof bottom | Cum | 11749.33 | 11749.33 | 14.0 | False | None | None | False | None | False | 164490.62 | 0 |
| 3384054 | 119187 | None | GKVK22 | do: Chajja | Cum | 10021.57 | 10021.57 | 2.5 | False | None | None | False | None | False | 25053.925 | 0 |
| 3384055 | 119187 | None | GKVK23 | do: Roof Beam & Lintel | Cum | 11058.29 | 11058.29 | 43.0 | False | None | None | False | None | False | 475506.47 | 0 |
| 3384056 | 119187 | None | GKVK24 | do: Roof Slab | Cum | 10367.15 | 10367.15 | 82.0 | False | None | None | False | None | False | 850106.3 | 0 |
| 3384057 | 119187 | None | GKVK25 | do: StairCase | Cum | 10367.15 | 10367.15 | 5.0 | False | None | None | False | None | False | 51835.75 | 0 |
| 3384058 | 119187 | None | GKVK26 | Terrace floor, Column upto Roof bottom | Cum | 11865.66 | 11865.66 | 1.0 | False | None | None | False | None | False | 11865.66 | 0 |
| 3384059 | 119187 | None | GKVK27 | do: Dummy column | Cum | 11749.33 | 11749.33 | 3.3 | False | None | None | False | None | False | 38772.789 | 0 |
| 3384060 | 119187 | None | GKVK28 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification For Buildings. Ground Floor | Tonne | 89457.0 | 89457.0 | 32.0 | False | None | None | False | None | False | 2862624.0 | 0 |
| 3384061 | 119187 | None | GKVK29 | do: FF | Tonne | 90351.57 | 90351.57 | 22.0 | False | None | None | False | None | False | 1987734.54 | 0 |
| 3384062 | 119187 | None | GKVK30 | do: TF | Tonne | 91246.14 | 91246.14 | 0.4 | False | None | None | False | None | False | 36498.456 | 0 |
| 3384063 | 119187 | None | GKVK31 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement :6 coarse sand) | Cum | 6389.0 | 6389.0 | 118.0 | False | None | None | False | None | False | 753902.0 | 0 |
| 3384064 | 119187 | None | GKVK32 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 255.0 | 255.0 | 64.96 | False | None | None | False | None | False | 16564.8 | 0 |
| 3384065 | 119187 | None | GKVK33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground Floor | Sqm | 1310.0 | 1310.0 | 455.0 | False | None | None | False | None | False | 596050.0 | 0 |
| 3384066 | 119187 | None | GKVK34 | do: FF | Sqm | 1323.1 | 1323.1 | 470.0 | False | None | None | False | None | False | 621857.0 | 0 |
| 3384067 | 119187 | None | GKVK35 | do: TF | Sqm | 1336.2 | 1336.2 | 130.0 | False | None | None | False | None | False | 173706.0 | 0 |
| 3384068 | 119187 | None | GKVK36 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1104.0 | 1104.0 | 30.0 | False | None | None | False | None | False | 33120.0 | 0 |
| 3384069 | 119187 | None | GKVK37 | do: FF | Sqm | 1115.04 | 1115.04 | 76.0 | False | None | None | False | None | False | 84743.04 | 0 |
| 3384070 | 119187 | None | GKVK38 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kgs | 168.0 | 168.0 | 1130.0 | False | None | None | False | None | False | 189840.0 | 0 |
| 3384071 | 119187 | None | GKVK39 | do: FF | Kgs | 169.68 | 169.68 | 1130.0 | False | None | None | False | None | False | 191738.4 | 0 |
| 3384072 | 119187 | None | GKVK40 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
c) Terrace Floor | Kgs | 124.44 | 124.44 | 200.0 | False | None | None | False | None | False | 24888.0 | 0 |
| 3384073 | 119187 | None | GKVK41 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Terrace Floor | Sqm | 579.36 | 579.36 | 28.0 | False | None | None | False | None | False | 16222.08 | 0 |
| 3384074 | 119187 | None | GKVK42 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets-grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5390.0 | 5390.0 | 38.7 | False | None | None | False | None | False | 208593.0 | 0 |
| 3384075 | 119187 | None | GKVK43 | do: FF | Sqm | 5443.9 | 5443.9 | 38.7 | False | None | None | False | None | False | 210678.93 | 0 |
| 3384076 | 119187 | None | GKVK44 | Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5719.0 | 5719.0 | 10.3 | False | None | None | False | None | False | 58905.7 | 0 |
| 3384077 | 119187 | None | GKVK45 | do: FF | Sqm | 5776.19 | 5776.19 | 10.3 | False | None | None | False | None | False | 59494.757 | 0 |
| 3384078 | 119187 | None | GKVK46 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 98815.0 | 98815.0 | 0.14 | False | None | None | False | None | False | 13834.1 | 0 |
| 3384079 | 119187 | None | GKVK47 | do: FF | Cum | 99803.15 | 99803.15 | 0.14 | False | None | None | False | None | False | 13972.441 | 0 |
| 3384080 | 119187 | None | GKVK48 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification.
-do- 35 mm thich one side teak and one side commercial | Sqm | 5897.0 | 5897.0 | 13.7 | False | None | None | False | None | False | 80788.9 | 0 |
| 3384081 | 119187 | None | GKVK49 | do: FF | Sqm | 5955.97 | 5955.97 | 13.7 | False | None | None | False | None | False | 81596.789 | 0 |
| 3384082 | 119187 | None | GKVK50 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge. (Fixtures shall be paid for separately/chowkhat of frame size 62 x 100mm | m | 702.0 | 702.0 | 64.0 | False | None | None | False | None | False | 44928.0 | 0 |
| 3384083 | 119187 | None | GKVK51 | FF BR+LF1%=702.00+7.02=709.02 | m | 709.02 | 709.02 | 64.0 | False | None | None | False | None | False | 45377.28 | 0 |
| 3384084 | 119187 | None | GKVK52 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. 35 mm thickness | Sqm | 4541.0 | 4541.0 | 22.0 | False | None | None | False | None | False | 99902.0 | 0 |
| 3384085 | 119187 | None | GKVK53 | do: FF | Sqm | 4586.41 | 4586.41 | 22.0 | False | None | None | False | None | False | 100901.02 | 0 |
| 3384086 | 119187 | None | GKVK54 | Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications. | Sqm | 1000.0 | 1000.0 | 537.0 | False | None | None | False | None | False | 537000.0 | 0 |
| 3384087 | 119187 | None | GKVK55 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 825.17 | 825.17 | 12.96 | False | None | None | False | None | False | 10694.2032 | 0 |
| 3384088 | 119187 | None | GKVK56 | Providing and laying polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Polished finish granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. | Sqm | 2852.0 | 2852.0 | 152.0 | False | None | None | False | None | False | 433504.0 | 0 |
| 3384089 | 119187 | None | GKVK57 | do: FF | Sqm | 2880.52 | 2880.52 | 149.0 | False | None | None | False | None | False | 429197.48 | 0 |
| 3384090 | 119187 | None | GKVK58 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | Mtr | 328.0 | 328.0 | 162.0 | False | None | None | False | None | False | 53136.0 | 0 |
| 3384091 | 119187 | None | GKVK59 | do: FF | Mtr | 331.28 | 331.28 | 145.0 | False | None | None | False | None | False | 48035.6 | 0 |
| 3384092 | 119187 | None | GKVK60 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 565.0 | 565.0 | 190.0 | False | None | None | False | None | False | 107350.0 | 0 |
| 3384093 | 119187 | None | GKVK61 | do: FF | Kgs | 570.65 | 570.65 | 130.0 | False | None | None | False | None | False | 74184.5 | 0 |
| 3384094 | 119187 | None | GKVK62 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. c) Terrace Floor | Sqm | 4326.84 | 4326.84 | 1.9 | False | None | None | False | None | False | 8220.996 | 0 |
| 3384095 | 119187 | None | GKVK63 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colors & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1175.0 | 1175.0 | 390.0 | False | None | None | False | None | False | 458250.0 | 0 |
| 3384096 | 119187 | None | GKVK64 | do: FF | Sqm | 1186.75 | 1186.75 | 390.0 | False | None | None | False | None | False | 462832.5 | 0 |
| 3384097 | 119187 | None | GKVK65 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1076.0 | 1076.0 | 43.0 | False | None | None | False | None | False | 46268.0 | 0 |
| 3384098 | 119187 | None | GKVK66 | do: FF | Sqm | 1086.76 | 1086.76 | 43.0 | False | None | None | False | None | False | 46730.68 | 0 |
| 3384099 | 119187 | None | GKVK67 | Providing skirting, dadooing, rises of steps with color glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labor, complete as per specifications. | Sqm | 1392.0 | 1392.0 | 122.0 | False | None | None | False | None | False | 169824.0 | 0 |
| 3384100 | 119187 | None | GKVK68 | do: FF | Sqm | 1405.92 | 1405.92 | 122.0 | False | None | None | False | None | False | 171522.24 | 0 |
| 3384101 | 119187 | None | GKVK69 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a. Ground Floor | Sqm | 349.0 | 349.0 | 750.0 | False | None | None | False | None | False | 261750.0 | 0 |
| 3384102 | 119187 | None | GKVK70 | do: FF | Sqm | 352.49 | 352.49 | 750.0 | False | None | None | False | None | False | 264367.5 | 0 |
| 3384103 | 119187 | None | GKVK71 | do: TF | Sqm | 355.98 | 355.98 | 45.0 | False | None | None | False | None | False | 16019.1 | 0 |
| 3384104 | 119187 | None | GKVK72 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 279.0 | 279.0 | 122.0 | False | None | None | False | None | False | 34038.0 | 0 |
| 3384105 | 119187 | None | GKVK73 | do: FF | Sqm | 281.79 | 281.79 | 122.0 | False | None | None | False | None | False | 34378.38 | 0 |
| 3384106 | 119187 | None | GKVK74 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 323.0 | 323.0 | 530.0 | False | None | None | False | None | False | 171190.0 | 0 |
| 3384107 | 119187 | None | GKVK75 | do: FF | Sqm | 326.23 | 326.23 | 530.0 | False | None | None | False | None | False | 172901.9 | 0 |
| 3384108 | 119187 | None | GKVK76 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per directions of Engineer-in-charge. a.Ground Floor | Sqm | 371.0 | 371.0 | 390.0 | False | None | None | False | None | False | 144690.0 | 0 |
| 3384109 | 119187 | None | GKVK77 | do: FF | Sqm | 374.71 | 374.71 | 425.0 | False | None | None | False | None | False | 159251.75 | 0 |
| 3384110 | 119187 | None | GKVK78 | do: Terrace Floor | Sqm | 378.42 | 378.42 | 250.0 | False | None | None | False | None | False | 94605.0 | 0 |
| 3384111 | 119187 | None | GKVK79 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 333.0 | 333.0 | 110.0 | False | None | None | False | None | False | 36630.0 | 0 |
| 3384112 | 119187 | None | GKVK80 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer incharge. | Sqm | 100.0 | 100.0 | 1280.0 | False | None | None | False | None | False | 128000.0 | 0 |
| 3384113 | 119187 | None | GKVK81 | do: FF | Sqm | 101.0 | 101.0 | 1280.0 | False | None | None | False | None | False | 129280.0 | 0 |
| 3384114 | 119187 | None | GKVK82 | do: TF | Sqm | 102.0 | 102.0 | 45.0 | False | None | None | False | None | False | 4590.0 | 0 |
| 3384115 | 119187 | None | GKVK83 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two coats) over and including water thinkable priming coat with cement primer after thoroughly booming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer -in -charge. | Sqm | 137.0 | 137.0 | 1280.0 | False | None | None | False | None | False | 175360.0 | 0 |
| 3384116 | 119187 | None | GKVK84 | do: FF | Sqm | 138.37 | 138.37 | 1280.0 | False | None | None | False | None | False | 177113.6 | 0 |
| 3384117 | 119187 | None | GKVK85 | do: TF | Sqm | 139.74 | 139.74 | 45.0 | False | None | None | False | None | False | 6288.3 | 0 |
| 3384118 | 119187 | None | GKVK86 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m2) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.0 | 142.0 | 390.0 | False | None | None | False | None | False | 55380.0 | 0 |
| 3384119 | 119187 | None | GKVK87 | do: FF | Sqm | 143.42 | 143.42 | 425.0 | False | None | None | False | None | False | 60953.5 | 0 |
| 3384120 | 119187 | None | GKVK88 | do: TF | Sqm | 144.84 | 144.84 | 250.0 | False | None | None | False | None | False | 36210.0 | 0 |
| 3384121 | 119187 | None | GKVK89 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m2 over an under coat of primer applied @0.75 ltr/10 m2 of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 138.0 | 138.0 | 15.6 | False | None | None | False | None | False | 2152.8 | 0 |
| 3384122 | 119187 | None | GKVK90 | do: FF | Sqm | 139.38 | 139.38 | 15.6 | False | None | None | False | None | False | 2174.328 | 0 |
| 3384123 | 119187 | None | GKVK91 | Melamine polishing on wood work (one coat) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor | Sqm | 106.0 | 106.0 | 15.6 | False | None | None | False | None | False | 1653.6 | 0 |
| 3384124 | 119187 | None | GKVK92 | do: FF | Sqm | 107.06 | 107.06 | 15.6 | False | None | None | False | None | False | 1670.136 | 0 |
| 3384125 | 119187 | None | GKVK93 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 115.0 | 115.0 | 55.0 | False | None | None | False | None | False | 6325.0 | 0 |
| 3384126 | 119187 | None | GKVK94 | do: FF | Sqm | 116.15 | 116.15 | 55.0 | False | None | None | False | None | False | 6388.25 | 0 |
| 3384127 | 119187 | None | GKVK95 | do: TF | Sqm | 117.3 | 117.3 | 4.0 | False | None | None | False | None | False | 469.2 | 0 |
| 3384128 | 119187 | None | GKVK96 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. | Each | 2345.0 | 2345.0 | 6.0 | False | None | None | False | None | False | 14070.0 | 0 |
| 3384129 | 119187 | None | GKVK97 | do: FF | Each | 2368.45 | 2368.45 | 6.0 | False | None | None | False | None | False | 14210.7 | 0 |
| 3384130 | 119187 | None | GKVK98 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. | Each | 1423.0 | 1423.0 | 6.0 | False | None | None | False | None | False | 8538.0 | 0 |
| 3384131 | 119187 | None | GKVK99 | do: FF | Each | 1437.23 | 1437.23 | 6.0 | False | None | None | False | None | False | 8623.38 | 0 |
| 3384132 | 119187 | None | GKVK100 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 |
| 3384133 | 119187 | None | GKVK101 | do: FF | Each | 4932.84 | 4932.84 | 2.0 | False | None | None | False | None | False | 9865.68 | 0 |
| 3384134 | 119187 | None | GKVK102 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Each | 4838.0 | 4838.0 | 6.0 | False | None | None | False | None | False | 29028.0 | 0 |
| 3384135 | 119187 | None | GKVK103 | do: FF | Each | 4886.38 | 4886.38 | 6.0 | False | None | None | False | None | False | 29318.28 | 0 |
| 3384136 | 119187 | None | GKVK104 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 8642.0 | 8642.0 | 3.0 | False | None | None | False | None | False | 25926.0 | 0 |
| 3384137 | 119187 | None | GKVK105 | do: FF | Each | 8728.42 | 8728.42 | 3.0 | False | None | None | False | None | False | 26185.26 | 0 |
| 3384138 | 119187 | None | GKVK106 | Providing and fixing approved Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook - Make Jaguar- ALD-573 | Each | 1625.0 | 1625.0 | 6.0 | False | None | None | False | None | False | 9750.0 | 0 |
| 3384139 | 119187 | None | GKVK107 | do: FF | Each | 1625.0 | 1625.0 | 6.0 | False | None | None | False | None | False | 9750.0 | 0 |
| 3384140 | 119187 | None | GKVK108 | Providing and fixing approved cp brass two way taps 15mm with flange etc.complete JAGUAR (CON 041 KN) | Each | 1375.0 | 1375.0 | 6.0 | False | None | None | False | None | False | 8250.0 | 0 |
| 3384141 | 119187 | None | GKVK109 | do: FF | Each | 1375.0 | 1375.0 | 6.0 | False | None | None | False | None | False | 8250.0 | 0 |
| 3384142 | 119187 | None | GKVK110 | Providing and fixing approved cp brass taps 15mm with flange etc.complete JAGUAR (CON 107 KN) | Each | 1600.0 | 1600.0 | 2.0 | False | None | None | False | None | False | 3200.0 | 0 |
| 3384143 | 119187 | None | GKVK111 | do: FF | Each | 1600.0 | 1600.0 | 2.0 | False | None | None | False | None | False | 3200.0 | 0 |
| 3384144 | 119187 | None | GKVK112 | Providing and fixing approved cp brass angle cock 15mm with flange etc. complete JAGUAR make (CON 059 KN) | Each | 1000.0 | 1000.0 | 14.0 | False | None | None | False | None | False | 14000.0 | 0 |
| 3384145 | 119187 | None | GKVK113 | do: FF | Each | 1000.0 | 1000.0 | 14.0 | False | None | None | False | None | False | 14000.0 | 0 |
| 3384146 | 119187 | None | GKVK114 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1220.0 | 1220.0 | 4.0 | False | None | None | False | None | False | 4880.0 | 0 |
| 3384147 | 119187 | None | GKVK115 | do: FF | Each | 1232.2 | 1232.2 | 4.0 | False | None | None | False | None | False | 4928.8 | 0 |
| 3384148 | 119187 | None | GKVK116 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 |
| 3384149 | 119187 | None | GKVK117 | do: FF | Each | 500.96 | 500.96 | 4.0 | False | None | None | False | None | False | 2003.84 | 0 |
| 3384150 | 119187 | None | GKVK118 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 63mm dia., 6 kg/sqcm & class 3 Make: Astral / Ashirvad / supreme | m | 161.0 | 161.0 | 20.0 | False | None | None | False | None | False | 3220.0 | 0 |
| 3384151 | 119187 | None | GKVK119 | do: FF | m | 162.61 | 162.61 | 20.0 | False | None | None | False | None | False | 3252.2 | 0 |
| 3384152 | 119187 | None | GKVK120 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 Make: Astral / Ashirvad / supreme | m | 220.0 | 220.0 | 20.0 | False | None | None | False | None | False | 4400.0 | 0 |
| 3384153 | 119187 | None | GKVK121 | do: FF | m | 222.2 | 222.2 | 20.0 | False | None | None | False | None | False | 4444.0 | 0 |
| 3384154 | 119187 | None | GKVK122 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 Make: Astral / Ashirvad / supreme | m | 411.0 | 411.0 | 129.0 | False | None | None | False | None | False | 53019.0 | 0 |
| 3384155 | 119187 | None | GKVK123 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 Make: Astral / Ashirvad / supreme | Mtr | 618.0 | 618.0 | 50.0 | False | None | None | False | None | False | 30900.0 | 0 |
| 3384156 | 119187 | None | GKVK124 | Providing and fixing CI Nahani trap of approved make conforming to ISI specification and construction of Cistern in M-15 as per directions(Rate is inclusive of cost of materials and fixture and conveyance of material to work spot ) -do 110 mm dia Make Supreme make | Each | 167.6 | 167.6 | 19.0 | False | None | None | False | None | False | 3184.4 | 0 |
| 3384157 | 119187 | None | GKVK125 | do: FF | Each | 167.6 | 167.6 | 19.0 | False | None | None | False | None | False | 3184.4 | 0 |
| 3384158 | 119187 | None | GKVK126 | Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia | Nos | 41.0 | 41.0 | 19.0 | False | None | None | False | None | False | 779.0 | 0 |
| 3384159 | 119187 | None | GKVK127 | do: FF | Nos | 41.41 | 41.41 | 19.0 | False | None | None | False | None | False | 786.79 | 0 |
| 3384160 | 119187 | None | GKVK128 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length. | Nos | 116.0 | 116.0 | 13.0 | False | None | None | False | None | False | 1508.0 | 0 |
| 3384161 | 119187 | None | GKVK129 | do: FF | Nos | 117.16 | 117.16 | 13.0 | False | None | None | False | None | False | 1523.08 | 0 |
| 3384162 | 119187 | None | GKVK130 | Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent and testing of joints complete as per direction of Engineer incharge. Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes V2 | Mtr | 379.0 | 379.0 | 40.0 | False | None | None | False | None | False | 15160.0 | 0 |
| 3384163 | 119187 | None | GKVK131 | do: FF | Mtr | 382.79 | 382.79 | 40.0 | False | None | None | False | None | False | 15311.6 | 0 |
| 3384164 | 119187 | None | GKVK132 | Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent trenching refilling & testing of joints complete as per the direction of engineer in-charge. (External walls etc.) 25 mm dia pipe nominal OD pipes V2 | Mtr | 296.0 | 296.0 | 40.0 | False | None | None | False | None | False | 11840.0 | 0 |
| 3384165 | 119187 | None | GKVK133 | do: FF | Mtr | 298.96 | 298.96 | 40.0 | False | None | None | False | None | False | 11958.4 | 0 |
| 3384166 | 119187 | None | GKVK134 | Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent trenching refilling & testing of joints complete as per the direction of engineer in-charge. (External walls etc.) 32 mm dia pipe nominal OD pipes | m | 372.0 | 372.0 | 50.0 | False | None | None | False | None | False | 18600.0 | 0 |
| 3384167 | 119187 | None | GKVK135 | Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 25mm dia nominal bore including cost of all materials, labor and HOM of equipments with all leads complete as per specifications. | Nos | 549.0 | 549.0 | 8.0 | False | None | None | False | None | False | 4392.0 | 0 |
| 3384168 | 119187 | None | GKVK136 | Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | Nos | 598.0 | 598.0 | 4.0 | False | None | None | False | None | False | 2392.0 | 0 |
| 3384169 | 119187 | None | GKVK137 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet. Pot let and overflow pipes but without fittings and the base support for tank. | Ltr | 9.0 | 9.0 | 4000.0 | False | None | None | False | None | False | 36000.0 | 0 |
| 3384170 | 119187 | None | GKVK138 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4791.0 | 4791.0 | 8.0 | False | None | None | False | None | False | 38328.0 | 0 |
| 3384171 | 119187 | None | GKVK139 | Providing and constructing WIRE CUT BRICK MACHINE HOLE CHAMBERS using Portland/ Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30 cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia, 1.0 M depth & SFRC cover & frame | Each | 31370.0 | 31370.0 | 1.0 | False | None | None | False | None | False | 31370.0 | 0 |
| 3384172 | 119187 | None | GKVK140 | Earth work excavation for pipelines cables by manual means upto 600 mm trench width as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. vol1 (P/I- 6/1.6) B.R- 484 | Cum | 484.0 | 484.0 | 61.0 | False | None | None | False | None | False | 29524.0 | 0 |
| 3384173 | 119187 | None | GKVK141 | Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary a)19/20mm dia 2mm thick | Mtr | 66.0 | 66.0 | 2200.0 | False | None | None | False | None | False | 145200.0 | 0 |
| 3384174 | 119187 | None | GKVK142 | do: b)25 mm dia 2 mm thick | Mtr | 78.0 | 78.0 | 1800.0 | False | None | None | False | None | False | 140400.0 | 0 |
| 3384175 | 119187 | None | GKVK143 | Supplying and fixing PVC/metal conduit Deep junction box a)19/20 mm deep Junction box | Each | 49.0 | 49.0 | 110.0 | False | None | None | False | None | False | 5390.0 | 0 |
| 3384176 | 119187 | None | GKVK144 | do: b) 25 mm deep Junction box | Each | 56.0 | 56.0 | 90.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3384177 | 119187 | None | GKVK145 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete a)upto 50 mm conduit in brick wall | Mtr | 29.0 | 29.0 | 390.0 | False | None | None | False | None | False | 11310.0 | 0 |
| 3384178 | 119187 | None | GKVK146 | Supplying And Fixing Metal Fan Box with Round Hook. | No. | 117.0 | 117.0 | 48.0 | False | None | None | False | None | False | 5616.0 | 0 |
| 3384179 | 119187 | None | GKVK147 | Point wiring using Copper wire without switch: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point upto 3m from tapping point to out let via switch box | Point | 269.0 | 269.0 | 20.0 | False | None | None | False | None | False | 5380.0 | 0 |
| 3384180 | 119187 | None | GKVK148 | do: a) Medium point above 3 Mtr. upto 6 Mtr. from tapping point to out let via switch box. | Point | 379.0 | 379.0 | 40.0 | False | None | None | False | None | False | 15160.0 | 0 |
| 3384181 | 119187 | None | GKVK149 | do: b) Long point above 6 Mtr. upto 10 Mtr. from tapping point to out let via switch box. | Point | 555.0 | 555.0 | 120.0 | False | None | None | False | None | False | 66600.0 | 0 |
| 3384182 | 119187 | None | GKVK150 | do: c) Two outlet in a row, above 3m upto 6m from tapping point to out let via switches | Point | 677.0 | 677.0 | 10.0 | False | None | None | False | None | False | 6770.0 | 0 |
| 3384183 | 119187 | None | GKVK151 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.a) 1.5 mm2 | Mtr | 26.0 | 26.0 | 2200.0 | False | None | None | False | None | False | 57200.0 | 0 |
| 3384184 | 119187 | None | GKVK152 | do: b) 2.5 m | Mtr | 42.0 | 42.0 | 1800.0 | False | None | None | False | None | False | 75600.0 | 0 |
| 3384185 | 119187 | None | GKVK153 | do: c) 4 mm2 | Mtr | 63.0 | 63.0 | 1050.0 | False | None | None | False | None | False | 66150.0 | 0 |
| 3384186 | 119187 | None | GKVK154 | do: d) 6 mm2 | Mtr | 92.0 | 92.0 | 750.0 | False | None | None | False | None | False | 69000.0 | 0 |
| 3384187 | 119187 | None | GKVK155 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, a)1-3 Way | Each | 159.0 | 159.0 | 15.0 | False | None | None | False | None | False | 2385.0 | 0 |
| 3384188 | 119187 | None | GKVK156 | do: b) 4-5 Way | Each | 177.0 | 177.0 | 18.0 | False | None | None | False | None | False | 3186.0 | 0 |
| 3384189 | 119187 | None | GKVK157 | do: c) 8 way | Each | 261.0 | 261.0 | 22.0 | False | None | None | False | None | False | 5742.0 | 0 |
| 3384190 | 119187 | None | GKVK158 | do: d) 10-12 way | Each | 319.0 | 319.0 | 25.0 | False | None | None | False | None | False | 7975.0 | 0 |
| 3384191 | 119187 | None | GKVK159 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. a)1 to 3 Module | Each | 161.0 | 161.0 | 15.0 | False | None | None | False | None | False | 2415.0 | 0 |
| 3384192 | 119187 | None | GKVK160 | do: b) 4 module | Each | 175.0 | 175.0 | 18.0 | False | None | None | False | None | False | 3150.0 | 0 |
| 3384193 | 119187 | None | GKVK161 | do: c) 8 module | Each | 284.0 | 284.0 | 22.0 | False | None | None | False | None | False | 6248.0 | 0 |
| 3384194 | 119187 | None | GKVK162 | do: d) 10-12 module | Each | 344.0 | 344.0 | 25.0 | False | None | None | False | None | False | 8600.0 | 0 |
| 3384195 | 119187 | None | GKVK163 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. a) 6A One way switch | Each | 102.0 | 102.0 | 230.0 | False | None | None | False | None | False | 23460.0 | 0 |
| 3384196 | 119187 | None | GKVK164 | do: b) 6A Two Way Switch | Each | 166.0 | 166.0 | 10.0 | False | None | None | False | None | False | 1660.0 | 0 |
| 3384197 | 119187 | None | GKVK165 | do: c) 6A Three Way socket | Each | 171.0 | 171.0 | 95.0 | False | None | None | False | None | False | 16245.0 | 0 |
| 3384198 | 119187 | None | GKVK166 | do: d) Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 48.0 | False | None | None | False | None | False | 17136.0 | 0 |
| 3384199 | 119187 | None | GKVK167 | do: e) 32A DP Switch | Each | 326.0 | 326.0 | 25.0 | False | None | None | False | None | False | 8150.0 | 0 |
| 3384200 | 119187 | None | GKVK168 | do: f) 6/16A Universal Socket | Each | 236.0 | 236.0 | 25.0 | False | None | None | False | None | False | 5900.0 | 0 |
| 3384201 | 119187 | None | GKVK169 | do: h) RJ45/I.O Outlet Cat-6 | Each | 337.0 | 337.0 | 28.0 | False | None | None | False | None | False | 9436.0 | 0 |
| 3384202 | 119187 | None | GKVK170 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE a) 100 Amp 25 KA | Each | 8487.0 | 8487.0 | 4.0 | False | None | None | False | None | False | 33948.0 | 0 |
| 3384203 | 119187 | None | GKVK171 | do: b)160 A 25 kA | Each | 13447.0 | 13447.0 | 1.0 | False | None | None | False | None | False | 13447.0 | 0 |
| 3384204 | 119187 | None | GKVK172 | do: c) 250 A 25 kA | Each | 21391.0 | 21391.0 | 1.0 | False | None | None | False | None | False | 21391.0 | 0 |
| 3384205 | 119187 | None | GKVK173 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a)6-32 Amps DP | Each | 739.0 | 739.0 | 20.0 | False | None | None | False | None | False | 14780.0 | 0 |
| 3384206 | 119187 | None | GKVK174 | do: b)50-63 A TPN | Each | 3088.0 | 3088.0 | 10.0 | False | None | None | False | None | False | 30880.0 | 0 |
| 3384207 | 119187 | None | GKVK175 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II- Double Door a)12 Way SP & N | Each | 2329.0 | 2329.0 | 3.0 | False | None | None | False | None | False | 6987.0 | 0 |
| 3384208 | 119187 | None | GKVK176 | do: b)III - Double Door 4 Way TP & N | Each | 4038.0 | 4038.0 | 2.0 | False | None | None | False | None | False | 8076.0 | 0 |
| 3384209 | 119187 | None | GKVK177 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
| 3384210 | 119187 | None | GKVK178 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. b)250 A 4 x 30 x 10 mm Aluminium Strips | Mtr | 3435.0 | 3435.0 | 3.0 | False | None | None | False | None | False | 10305.0 | 0 |
| 3384211 | 119187 | None | GKVK179 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. a)50 x 50 x 6 mm | Mtr | 395.0 | 395.0 | 10.0 | False | None | None | False | None | False | 3950.0 | 0 |
| 3384212 | 119187 | None | GKVK180 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.a)14 SWG | Sq CM | 0.5 | 0.5 | 90000.0 | False | None | None | False | None | False | 45000.0 | 0 |
| 3384213 | 119187 | None | GKVK181 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 562.0 | 562.0 | 3.0 | False | None | None | False | None | False | 1686.0 | 0 |
| 3384214 | 119187 | None | GKVK182 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1492.0 | 1492.0 | 8.0 | False | None | None | False | None | False | 11936.0 | 0 |
| 3384215 | 119187 | None | GKVK183 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. a) 48” Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 48.0 | False | None | None | False | None | False | 143232.0 | 0 |
| 3384216 | 119187 | None | GKVK184 | Supplying and drawing UTP-CAT 6E LAN cable. | Mtr | 38.0 | 38.0 | 350.0 | False | None | None | False | None | False | 13300.0 | 0 |
| 3384217 | 119187 | None | GKVK185 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V@ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a)LED light fitting 1 x 2' - 9/10 W (P/I-43/11.3.1) | Each | 551.0 | 551.0 | 10.0 | False | None | None | False | None | False | 5510.0 | 0 |
| 3384218 | 119187 | None | GKVK186 | do: b)LED light fitting1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 98.0 | False | None | None | False | None | False | 67620.0 | 0 |
| 3384219 | 119187 | None | GKVK187 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @50/60Hz & Power factor more than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15-18W | Each | 1324.0 | 1324.0 | 30.0 | False | None | None | False | None | False | 39720.0 | 0 |
| 3384220 | 119187 | None | GKVK188 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 138.0 | False | None | None | False | None | False | 16836.0 | 0 |
| 3384221 | 119187 | None | GKVK189 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 48.0 | False | None | None | False | None | False | 8208.0 | 0 |
| 3384222 | 119187 | None | GKVK190 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 492.0 | 492.0 | 8.0 | False | None | None | False | None | False | 3936.0 | 0 |
| 3384223 | 119187 | None | GKVK191 | Rod type of earthing using 40mm Dia,3Mtr long MS rod as ground rod ,in earth pit of 300mm width and 3300mm depth and using 50x6mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No. | 2172.0 | 2172.0 | 4.0 | False | None | None | False | None | False | 8688.0 | 0 |
| 3384224 | 119187 | None | GKVK192 | 1.1kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LT UG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm, 3.5Core, (21 GI Strips-4x0.8mm) | Km | 373215.0 | 373215.0 | 0.135 | False | None | None | False | None | False | 50384.025 | 0 |
| 3384225 | 119187 | None | GKVK193 | GI Pipe B-Class as per IS-1239 GI Pipe-150mm Dia | Mtr | 1529.0 | 1529.0 | 15.0 | False | None | None | False | None | False | 22935.0 | 0 |
| 3384226 | 119187 | None | GKVK194 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt:58Gm | No. | 129.0 | 129.0 | 16.0 | False | None | None | False | None | False | 2064.0 | 0 |
| 3384227 | 119187 | None | GKVK195 | EpoxyTerminatingKit(Pothead)suitable for1.1kV,LTUGCable 3.5x70/95/120Sqmm | No. | 382.0 | 382.0 | 1.0 | False | None | None | False | None | False | 382.0 | 0 |
| 3384228 | 119187 | None | GKVK196 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency more than1301m/w, nominal CRI more than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W | Each | 6768.0 | 6768.0 | 3.0 | False | None | None | False | None | False | 20304.0 | 0 |
| 3384229 | 119187 | None | GKVK197 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |