createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719550664115
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd635000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 16:00:00
tenderQueryClose03-07-2024 16:00:00
technicalBidOpen12-07-2024 16:30:00
publishedDate28-06-2024 12:55:14
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate04-07-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1719550664145
version5
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT451
titleConstruction of Health and Wellness Centre at 1)Kapoli in Khanapura Tq, 2)Paramanandawad in Raibag Tq, 3)Sultanpur in Hukkeri Tq, 4)Aaralihatti in Athani Tq, 5)Kohalli in Athani Tq, 6)Badli in Savadatti Tq, 7)Chippalkatti in Ramdurga Tq, in Belagavi District(Package-BGI)
descriptionConstruction of Health and Wellness Centre at 1)Kapoli in Khanapura Tq, 2)Paramanandawad in Raibag Tq, 3)Sultanpur in Hukkeri Tq, 4)Aaralihatti in Athani Tq, 5)Kohalli in Athani Tq, 6)Badli in Savadatti Tq, 7)Chippalkatti in Ramdurga Tq, in Belagavi District(Package-BGI)
categoryWORKS
categoryTextWorks
ecv42319678.17
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount42500000.0
groupOverheadTotal0.0
fileNumberAEE/BGM/2023-24/15thfinance/HWC
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17195506640000NoneNoneBuildingsKapoli HWC GF Civil Work Slice-13976504.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391047119477NoneCommon PWD SR 23-24 V-1 Pg no 8 Item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36154.94FalseNoneNoneFalseNoneFalse18648.57840
3391048119477NoneCommon PWD SR 23-24 V-1 Pg no 15 Item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391049119477NoneCommon PWD SR 23-24 V-1 Pg no 15 Item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for footing ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391050119477NoneCommon PWD SR 23-24 V-1 Pg no 15 Item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.528160.521.79FalseNoneNoneFalseNoneFalse14607.33080
3391051119477NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for columns ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.15FalseNoneNoneFalseNoneFalse95093.4270
3391052119477NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam,Slab, Staircase ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.38FalseNoneNoneFalseNoneFalse356512.3380
3391053119477NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC Beam and Lintel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4414.75FalseNoneNoneFalseNoneFalse184632.240
3391054119477NoneCommon PWD SR 23-24 V-1 Pg no 7 Item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.16FalseNoneNoneFalseNoneFalse56548.62080
3391055119477NoneCommon PWD SR 23-24 V-1 Pg no 15 Item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.064.16FalseNoneNoneFalseNoneFalse30518.00960
3391056119477NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.4FalseNoneNoneFalseNoneFalse4537.5720
3391057119477NoneCommon PWD SR 23-24 V-1 Pg no 18 Item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.267.46FalseNoneNoneFalseNoneFalse787472.07960
3391058119477NoneCommon PWD SR 23-24 V-2 Pg no 9 Item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3391059119477NoneCommon PWD SR 23-24 V-2 Pg no 13 Item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3391060119477NoneCommon PWD SR 23-24 V-2 Pg no 14 Item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3391061119477NoneCommon PWD SR 23-24 V-2 Pg no 100 Item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.48FalseNoneNoneFalseNoneFalse55968.8160
3391062119477NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3391063119477NoneCommon PWD SR 23-24 V-2 Pg no A-25 Item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3391064119477NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3391065119477NoneCommon PWD SR 23-24 V-2 Pg no 110 Item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3391066119477NoneCommon PWD SR 23-24 V-2 Pg no 109 Item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3391067119477NoneCommon PWD SR 23-24 V-2 Pg no 86 Item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.37FalseNoneNoneFalseNoneFalse58157.66880
3391068119477NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3391069119477NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3391070119477NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3391071119477NoneCommon PWD SR 23-24 V-2 Pg no 42 Item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.25FalseNoneNoneFalseNoneFalse181303.7550
3391072119477NoneCommon PWD SR 23-24 V-2 Pg no 50 Item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.23FalseNoneNoneFalseNoneFalse62095.140
3391073119477NoneCommon PWD SR 23-24 V-2 Pg no 42 Item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78264.43FalseNoneNoneFalseNoneFalse115762.16540
3391074119477NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.42FalseNoneNoneFalseNoneFalse13374.0020
3391075119477NoneCommon PWD SR 23-24 V-2 Pg no 149 Item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3391076119477NoneCommon PWD SR 23-24 V-2 Pg no 60 Item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3391077119477NoneCommon PWD SR 23-24 V-2 Pg no 63 Item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.97FalseNoneNoneFalseNoneFalse69749.82360
3391078119477NoneCommon PWD SR 23-24 V-2 Pg no 60 Item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.07FalseNoneNoneFalseNoneFalse13710.69140
3391079119477NoneCommon PWD SR 23-24 V-2 Pg no 65 Item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.42FalseNoneNoneFalseNoneFalse63107.15520
3391080119477NoneCommon PWD SR 23-24 V-2 Pg no 64 Item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3391081119477NoneCommon PWD SR 23-24 V-2 Pg no 63 Item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.17FalseNoneNoneFalseNoneFalse46593.50360
3391082119477NoneCommon PWD SR 23-24 V-2 Pg no 83 Item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3391083119477NoneCommon PWD SR 23-24 V-2 Pg no 48 Item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.25FalseNoneNoneFalseNoneFalse65975.8650
3391084119477NoneCommon PWD SR 23-24 V-2 Pg no 46 Item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32264.43FalseNoneNoneFalseNoneFalse54292.76760
3391085119477NoneCommon PWD SR 23-24 V-2 Pg no 47 Item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3391086119477NoneCommon PWD SR 23-24 V-2 Pg no 48 Item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3391087119477NoneCommon PWD SR 23-24 V-2 Pg no 47 Item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.19FalseNoneNoneFalseNoneFalse4827.46260
3391088119477NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3391089119477NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3391090119477NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3391091119477NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3391092119477NoneCommon PWD SR 23-24 V-1 Pg no 9 Item no 1.15.2Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the xcavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/ soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.524.77FalseNoneNoneFalseNoneFalse12422.1550
3391093119477NoneCommon PWD SR 23-24 V-1 Pg no 17 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed withsuper plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead & lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.0812.38FalseNoneNoneFalseNoneFalse116224.43040
3391094119477NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.959.0FalseNoneNoneFalseNoneFalse17753.10
3391095119477NoneCommon PWD SR 23-24 V-2 Pg no 136 Item no 15.6Food Graded Water Proofing Membrane : Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modifiedcementitious waterproofing membrane with minimum elongation of 50%applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in twocoats certified by CFTRI Mysuru, including surface preparation completelyas per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2659.0FalseNoneNoneFalseNoneFalse35297.340
3391096119477NoneCommon PWD SR 23-24 V-5 Pg no 221 Item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.163.0FalseNoneNoneFalseNoneFalse6945.480
3391097119477NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3391098119477NoneCommon PWD SR 23-24 V-2 Pg no 187 Item no 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2862.682862.6814.24FalseNoneNoneFalseNoneFalse40764.56320
3391099119477NoneCommon PWD SR 23-24 V-2 Pg no 188 Item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.13FalseNoneNoneFalseNoneFalse49763.11340
17195506640000NoneNoneBuildingsKapoli HWC FF Civil Work Slice-11827534.44
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391100119478NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Columns ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7713432.774.23FalseNoneNoneFalseNoneFalse56820.61710
3391101119478NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC Beam And Lintel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.6110.27FalseNoneNoneFalseNoneFalse129839.60470
3391102119478NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC Slab ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.83FalseNoneNoneFalseNoneFalse80952.23350
3391103119478NoneCommon PWD SR 23-24 V-1 Pg no 15 Item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.04FalseNoneNoneFalseNoneFalse7705.79680
3391104119478NoneCommon PWD SR 23-24 V-1 Pg no 16 Item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11457.3611457.360.46FalseNoneNoneFalseNoneFalse5270.38560
3391105119478NoneCommon PWD SR 23-24 V-1 Pg no 18 Item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.91FalseNoneNoneFalseNoneFalse203634.36350
3391106119478NoneCommon PWD SR 23-24 V-2 Pg no 13 Item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12356.1512356.1535.17FalseNoneNoneFalseNoneFalse434565.79550
3391107119478NoneCommon PWD SR 23-24 V-2 Pg no 14 Item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.341438.3442.39FalseNoneNoneFalseNoneFalse60971.23260
3391108119478NoneCommon PWD SR 23-24 V-2 Pg no 100 Item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.71117767.710.22FalseNoneNoneFalseNoneFalse25908.89620
3391109119478NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.861210.864.0FalseNoneNoneFalseNoneFalse4843.440
3391110119478NoneCommon PWD SR 23-24 V-2 Pg no A-25 Item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.5959.5924.0FalseNoneNoneFalseNoneFalse1430.160
3391111119478NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3391112119478NoneCommon PWD SR 23-24 V-2 Pg no 110 Item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3391113119478NoneCommon PWD SR 23-24 V-2 Pg no 110 Item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3391114119478NoneCommon PWD SR 23-24 V-2 Pg no 86 Item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.67FalseNoneNoneFalseNoneFalse47386.06740
3391115119478NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3391116119478NoneCommon PWD SR 23-24 V-2 Pg no 104 Item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.032436.033.15FalseNoneNoneFalseNoneFalse7673.49450
3391117119478NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.71FalseNoneNoneFalseNoneFalse26449.91450
3391118119478NoneCommon PWD SR 23-24 V-2 Pg no 42 Item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.93415.93240.56FalseNoneNoneFalseNoneFalse100056.12080
3391119119478NoneCommon PWD SR 23-24 V-2 Pg no 50 Item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.27FalseNoneNoneFalseNoneFalse36858.79860
3391120119478NoneCommon PWD SR 23-24 V-2 Pg no 42 Item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.15442.15204.47FalseNoneNoneFalseNoneFalse90406.41050
3391121119478NoneCommon PWD SR 23-24 V-2 Pg no 41 Item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3391122119478NoneCommon PWD SR 23-24 V-2 Pg no 149 Item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.87FalseNoneNoneFalseNoneFalse74848.3190
3391123119478NoneCommon PWD SR 23-24 V-2 Pg no 60 Item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3391124119478NoneCommon PWD SR 23-24 V-2 Pg no 60 Item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.99FalseNoneNoneFalseNoneFalse6346.46490
3391125119478NoneCommon PWD SR 23-24 V-2 Pg no 65 Item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.981658.9827.87FalseNoneNoneFalseNoneFalse46235.77260
3391126119478NoneCommon PWD SR 23-24 V-2 Pg no 65 Item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3391127119478NoneCommon PWD SR 23-24 V-2 Pg no 64 Item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.895131.899.81FalseNoneNoneFalseNoneFalse50343.84090
3391128119478NoneCommon PWD SR 23-24 V-2 Pg no 48 Item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.35151.35240.56FalseNoneNoneFalseNoneFalse36408.7560
3391129119478NoneCommon PWD SR 23-24 V-2 Pg no 46 Item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.023FalseNoneNoneFalseNoneFalse38160.849510
3391130119478NoneCommon PWD SR 23-24 V-2 Pg no 45 Item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.27337.2720.45FalseNoneNoneFalseNoneFalse6897.17150
3391131119478NoneCommon PWD SR 23-24 V-2 Pg no 47 Item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3391132119478NoneCommon PWD SR 23-24 V-2 Pg no 48 Item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.05137.0511.27FalseNoneNoneFalseNoneFalse1544.55350
3391133119478NoneCommon PWD SR 23-24 V-2 Pg no 47 Item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1663.1621.89FalseNoneNoneFalseNoneFalse1382.57240
3391134119478NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3391135119478NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.01143.015.0FalseNoneNoneFalseNoneFalse715.050
3391136119478NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.771253.775.0FalseNoneNoneFalseNoneFalse6268.850
3391137119478NoneCommon PWD SR 23-24 V-2 Pg no 105 Item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506640000NoneNoneBuildingsKapoli HWC WS Work Slice-1291986.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391138119479NoneCommon PWD SR 23-24 V-2 Pg no 131 Item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3391139119479NoneCommon PWD SR 23-24 V-2 Pg no 131 Item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3391140119479NoneCommon PWD SR 23-24 V-2 Pg no 133 Item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3391141119479NoneCommon PWD SR 23-24 V-2 Pg no 135 Item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3391142119479NoneCommon PWD SR 23-24 V-2 Pg no 135 Item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3391143119479NoneCommonPWD SR 23-24 V-2 Pg no 133 Item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3391144119479NoneCommon PWD SR 23-24 V-2 Pg no 136 Item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3391145119479NoneCommon PWD SR 23-24 V-2 Pg no 127 Item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3391146119479NoneCommon PWD SR 23-24 V-2 Pg no 137 Item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3391147119479NoneCommon PWD SR 23-24 V-2 Pg no 137 Item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3391148119479NoneCommon PWD SR 23-24 V-2 Pg no 121 Item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3391149119479NoneCommon PWD SR 23-24 V-5 Pg no 113 Item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.630.0FalseNoneNoneFalseNoneFalse7788.00
3391150119479NoneCommon PWD SR 23-24 V-5 Pg no 113 Item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9225.0FalseNoneNoneFalseNoneFalse8673.00
3391151119479NoneCommon PWD SR 23-24 V-5 Pg no 113 Item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.9820.0FalseNoneNoneFalseNoneFalse9699.60
3391152119479NoneCommon PWD SR 23-24 V-5 Pg no 113 Item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1225.0FalseNoneNoneFalseNoneFalse17228.00
3391153119479NoneCommon PWD SR 23-24 V-2 Pg no 122 Item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3391154119479NoneCommon PWD SR 23-24 V-2 Pg no 122 Item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3391155119479NoneCommon PWD SR 23-24 V-2 Pg no 122 Item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3391156119479NoneCommon PWD SR 23-24 V-2 Pg no 122 Item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3391157119479NoneCommon PWD SR 23-24 V-2 Pg no 123 Item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8624.0FalseNoneNoneFalseNoneFalse13508.640
3391158119479NoneCommon PWD SR 23-24 V-2 Pg no 125 Item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3391159119479NoneCommon PWD SR 23-24 V-2 Pg no 120 Item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.622000.0FalseNoneNoneFalseNoneFalse21240.00
3391160119479NoneCommon PWD SR 23-24 V-5 Pg no 191 Item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.724.0FalseNoneNoneFalseNoneFalse25742.880
3391161119479NoneCommon PWD SR 23-24 V-2 Pg no 136 Item no 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1439.61439.62.0FalseNoneNoneFalseNoneFalse2879.20
3391162119479NoneCommon PWD SR 23-24 V-2 Pg no A-16 Item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.510.0FalseNoneNoneFalseNoneFalse6195.00
3391163119479NoneCommon PWD SR 23-24 V-2 Pg no A-15 Item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3391164119479NoneCommon PWD SR 23-24 V-2 Pg no 116 Item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3391165119479NoneCommonPWD SR 23-24 V-2 Pg no 136 Item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5610.0FalseNoneNoneFalseNoneFalse1085.60
3391166119479NoneCommon PWD SR 23-24 V-2 Pg no 121 Item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3391167119479NoneCommon PWD SR 23-24 V-6 Pg no 34 Item no 7.3.2Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.-200 L ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55358.5255358.521.0FalseNoneNoneFalseNoneFalse55358.520
3391168119479NoneCommon PWD SR 23-24 V-5 Pg no 149 Item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments Etc complete-0.50 HP/0.37kW - 5 STG(stage) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506640000NoneNoneBuildingsKapoli HWC Electrical Work Slice-1378055.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391169119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3391170119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3391171119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3391172119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3391173119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3391174119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391175119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3391176119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3391177119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3391178119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3391179119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3391180119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3391181119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3391182119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3391183119480NoneCommon PWD SR 23-24 V-6 Pg no 8 Item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3391184119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.- 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3391185119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3391186119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3391187119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391188119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.4Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3391189119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.932Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3391190119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.106/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3391191119480NoneCommon PWD SR 23-24 V-6 Pg no 9 Item no 3.6.11TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3391192119480NoneCommon PWD SR 23-24 V-6 Pg no 48 Item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3391193119480NoneCommon PWD SR 23-24 V-6 Pg no 4 Item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3391194119480NoneCommon PWD SR 23-24 V-6 Pg no 2 Item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88175.0FalseNoneNoneFalseNoneFalse13629.00
3391195119480NoneCommon PWD SR 23-24 V-6 Pg no 2 Item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3391196119480NoneCommon PWD SR 23-24 V-6 Pg no 2 Item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24175.0FalseNoneNoneFalseNoneFalse14042.00
3391197119480NoneCommon PWD SR 23-24 V-6 Pg no 2 Item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3391198119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.- 1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3391199119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.- 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3391200119480NoneCommon PWD SR 23-24 V-6 Pg no 5 Item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.- 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3391201119480NoneCommon PWD SR 23-24 V-6 Pg no 18 Item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure- II - Double Door- 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3391202119480NoneCommon PWD SR 23-24 V-6 Pg no 17 Item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3391203119480NoneCommon PWD SR 23-24 V-6 Pg no 18 Item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board- 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3391204119480NoneCommon PWD SR 23-24 V-6 Pg no 43 Item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3391205119480NoneCommon PWD SR 23-24 V-6 Pg no 47 Item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.- 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3391206119480NoneCommon PWD SR 23-24 V-6 Pg no 47 Item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.- 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3391207119480NoneCommon PWD SR 23-24 V-6 Pg no 50 Item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3391208119480NoneCommon PWD SR 23-24 V-6 Pg no 30 Item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3391209119480NoneCommon PWD SR 23-24 V-6 Pg no 30 Item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.- 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3391210119480NoneCommon PWD SR 23-24 V-6 Pg no 52 Item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3391211119480NoneCommon PWD SR 23-24 V-6 Pg no 56 Item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.- On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3391212119480NoneCommon PWD SR 23-24 V-6 Pg no 57 Item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3391213119480NoneCommon PWD SR 23-24 V-6 Pg no 57 Item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3391214119480NoneCommon PWD SR 23-24 V-6 Pg no 56 Item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories.- Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3391215119480NoneCommon PWD SR 23-24 V-6 Pg no 13 Item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3391216119480NoneCommon PWD SR 23-24 V-6 Pg no 52 Item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-2.5 to 25 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3391217119480None19-20 SR Item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR -32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3391218119480None19-20 SR Item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 19-20 SR-10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3391219119480None21-22 SR BSR Item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3391220119480NoneCommon PWD SR 23-24 V-6 Pg no 20 Item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3391221119480NoneCommon PWD SR 23-24 V-6 Pg no 20 Item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3391222119480NoneCommon PWD SR 23-24 V-6 Pg no 20 Item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint-75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3391223119480NoneCommon PWD SR 23-24 V-6 Pg no 56 Item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3391224119480NoneCommon PWD SR 23-24 V-6 Pg no 34 Item no 7.1.2Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.- 15Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10342.710342.71.0FalseNoneNoneFalseNoneFalse10342.70
3391225119480NoneCommon PWD SR 23-24 V-6 Pg no 20 Item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.- 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3391226119480NoneCommon PWD SR 23-24 V-6 Pg no 20 Item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint - 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3391227119480NoneCommon PWD SR 23-24 V-6 Pg no 17 Item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3391228119480NoneCommon PWD SR 23-24 V-6 Pg no 18 Item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3391229119480NoneCommon PWD SR 23-24 V-6 Pg no 14 Item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers- 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3391230119480NoneCommon PWD SR 23-24 V-6 Pg no 14 Item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers- 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3391231119480NoneCommon PWD SR 23-24 V-6 Pg no 15 Item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3391232119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3391233119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3391234119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3391235119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3391236119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3391237119480NoneCommon PWD SR 23-24 V-6 Pg no 19 Item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506640000NoneNoneBuildingsParamanandawad HWC GF Civil Work Slice-23606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391238119481NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3391239119481NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391240119481NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391241119481NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3391242119481NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3391243119481NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3391244119481NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3391245119481NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3391246119481NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3391247119481NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3391248119481NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3391249119481NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3391250119481NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3391251119481NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3391252119481NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3391253119481NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3391254119481NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3391255119481NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3391256119481NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3391257119481NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3391258119481NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3391259119481NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3391260119481NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3391261119481NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3391262119481NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3391263119481NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3391264119481NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3391265119481NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3391266119481NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3391267119481NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3391268119481NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3391269119481NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3391270119481NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3391271119481NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3391272119481NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3391273119481NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3391274119481NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3391275119481NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3391276119481NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3391277119481NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3391278119481NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3391279119481NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3391280119481NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3391281119481NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3391282119481NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3391283119481NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3391284119481NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3391285119481NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3391286119481NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3391287119481NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3391288119481NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3391289119481NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506640000NoneNoneBuildingsParamanandawad HWC FF Civil Work Slice-21768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391290119482NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3391291119482NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3391292119482NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3391293119482NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3391294119482NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3391295119482NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3391296119482NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3391297119482NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3391298119482NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3391299119482NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3391300119482NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3391301119482NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3391302119482NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3391303119482NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3391304119482NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3391305119482NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3391306119482NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3391307119482NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3391308119482NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3391309119482NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3391310119482NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3391311119482NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3391312119482NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3391313119482NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3391314119482NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3391315119482NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3391316119482NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3391317119482NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3391318119482NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3391319119482NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3391320119482NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3391321119482NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3391322119482NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3391323119482NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3391324119482NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3391325119482NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3391326119482NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3391327119482NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3391328119482NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506640000NoneNoneBuildingsParamanandawad HWC WS Work Slice-2233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391329119483NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3391330119483NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3391331119483NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3391332119483NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3391333119483NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3391334119483NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3391335119483NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3391336119483NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3391337119483NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3391338119483NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3391339119483NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3391340119483NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3391341119483NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3391342119483NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3391343119483NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3391344119483NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3391345119483NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3391346119483NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3391347119483NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3391348119483NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3391349119483NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3391350119483NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3391351119483NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3391352119483NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3391353119483NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3391354119483NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3391355119483NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3391356119483NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3391357119483NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506640000NoneNoneBuildingsParamanandawad HWC Electrical Work Slice-2366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391358119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3391359119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3391360119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3391361119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3391362119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3391363119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391364119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3391365119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3391366119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3391367119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3391368119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3391369119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3391370119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3391371119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3391372119484NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3391373119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3391374119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3391375119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3391376119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391377119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3391378119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3391379119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3391380119484NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3391381119484NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3391382119484NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3391383119484NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3391384119484NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3391385119484NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3391386119484NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3391387119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3391388119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3391389119484NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3391390119484NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3391391119484NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3391392119484NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3391393119484NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3391394119484NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3391395119484NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3391396119484NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3391397119484NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3391398119484NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3391399119484NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3391400119484NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3391401119484NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3391402119484NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3391403119484NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3391404119484NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3391405119484NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3391406119484None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3391407119484None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3391408119484None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3391409119484NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3391410119484NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3391411119484NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3391412119484NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3391413119484NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3391414119484NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3391415119484NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3391416119484NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3391417119484NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3391418119484NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3391419119484NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3391420119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3391421119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3391422119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3391423119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3391424119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3391425119484NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506640000NoneNoneBuildingsSultanpur HWC GF Civil Work Slice-33606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391426119485NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3391427119485NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391428119485NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391429119485NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3391430119485NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3391431119485NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3391432119485NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3391433119485NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3391434119485NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3391435119485NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3391436119485NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3391437119485NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3391438119485NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3391439119485NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3391440119485NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3391441119485NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3391442119485NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3391443119485NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3391444119485NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3391445119485NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3391446119485NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3391447119485NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3391448119485NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3391449119485NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3391450119485NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3391451119485NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3391452119485NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3391453119485NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3391454119485NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3391455119485NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3391456119485NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3391457119485NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3391458119485NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3391459119485NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3391460119485NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3391461119485NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3391462119485NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3391463119485NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3391464119485NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3391465119485NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3391466119485NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3391467119485NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3391468119485NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3391469119485NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3391470119485NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3391471119485NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3391472119485NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3391473119485NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3391474119485NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3391475119485NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3391476119485NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3391477119485NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506640000NoneNoneBuildingsSultanpur HWC FF Civil Work Slice-31768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391478119486NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3391479119486NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3391480119486NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3391481119486NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3391482119486NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3391483119486NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3391484119486NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3391485119486NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3391486119486NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3391487119486NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3391488119486NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3391489119486NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3391490119486NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3391491119486NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3391492119486NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3391493119486NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3391494119486NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3391495119486NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3391496119486NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3391497119486NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3391498119486NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3391499119486NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3391500119486NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3391501119486NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3391502119486NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3391503119486NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3391504119486NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3391505119486NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3391506119486NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3391507119486NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3391508119486NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3391509119486NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3391510119486NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3391511119486NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3391512119486NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3391513119486NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3391514119486NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3391515119486NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3391516119486NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506640000NoneNoneBuildingsSultanpur HWC WS Work Slice-3233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391517119487NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3391518119487NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3391519119487NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3391520119487NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3391521119487NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3391522119487NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3391523119487NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3391524119487NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3391525119487NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3391526119487NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3391527119487NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3391528119487NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3391529119487NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3391530119487NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3391531119487NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3391532119487NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3391533119487NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3391534119487NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3391535119487NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3391536119487NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3391537119487NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3391538119487NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3391539119487NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3391540119487NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3391541119487NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3391542119487NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3391543119487NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3391544119487NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3391545119487NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506640000NoneNoneBuildingsSultanpur HWC Electrical Work Slice-3366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391546119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3391547119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3391548119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3391549119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3391550119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3391551119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391552119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3391553119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3391554119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3391555119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3391556119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3391557119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3391558119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3391559119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3391560119488NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3391561119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3391562119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3391563119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3391564119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391565119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3391566119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3391567119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3391568119488NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3391569119488NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3391570119488NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3391571119488NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3391572119488NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3391573119488NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3391574119488NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3391575119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3391576119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3391577119488NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3391578119488NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3391579119488NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3391580119488NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3391581119488NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3391582119488NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3391583119488NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3391584119488NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3391585119488NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3391586119488NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3391587119488NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3391588119488NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3391589119488NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3391590119488NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3391591119488NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3391592119488NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3391593119488NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3391594119488None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3391595119488None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3391596119488None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3391597119488NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3391598119488NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3391599119488NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3391600119488NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3391601119488NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3391602119488NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3391603119488NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3391604119488NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3391605119488NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3391606119488NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3391607119488NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3391608119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3391609119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3391610119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3391611119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3391612119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3391613119488NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506640000NoneNoneBuildingsAaralihatti HWC GF Civil Work Slice-43606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391614119489NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3391615119489NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391616119489NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391617119489NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3391618119489NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3391619119489NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3391620119489NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3391621119489NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3391622119489NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3391623119489NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3391624119489NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3391625119489NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3391626119489NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3391627119489NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3391628119489NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3391629119489NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3391630119489NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3391631119489NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3391632119489NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3391633119489NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3391634119489NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3391635119489NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3391636119489NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3391637119489NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3391638119489NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3391639119489NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3391640119489NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3391641119489NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3391642119489NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3391643119489NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3391644119489NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3391645119489NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3391646119489NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3391647119489NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3391648119489NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3391649119489NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3391650119489NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3391651119489NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3391652119489NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3391653119489NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3391654119489NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3391655119489NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3391656119489NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3391657119489NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3391658119489NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3391659119489NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3391660119489NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3391661119489NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3391662119489NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3391663119489NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3391664119489NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3391665119489NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506640000NoneNoneBuildingsAaralihatti HWC FF Civil Work Slice-41768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391666119490NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3391667119490NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3391668119490NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3391669119490NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3391670119490NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3391671119490NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3391672119490NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3391673119490NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3391674119490NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3391675119490NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3391676119490NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3391677119490NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3391678119490NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3391679119490NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3391680119490NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3391681119490NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3391682119490NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3391683119490NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3391684119490NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3391685119490NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3391686119490NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3391687119490NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3391688119490NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3391689119490NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3391690119490NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3391691119490NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3391692119490NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3391693119490NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3391694119490NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3391695119490NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3391696119490NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3391697119490NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3391698119490NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3391699119490NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3391700119490NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3391701119490NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3391702119490NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3391703119490NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3391704119490NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506640000NoneNoneBuildingsAaralihatti HWC WS Work Slice-4233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391705119491NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3391706119491NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3391707119491NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3391708119491NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3391709119491NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3391710119491NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3391711119491NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3391712119491NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3391713119491NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3391714119491NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3391715119491NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3391716119491NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3391717119491NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3391718119491NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3391719119491NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3391720119491NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3391721119491NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3391722119491NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3391723119491NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3391724119491NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3391725119491NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3391726119491NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3391727119491NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3391728119491NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3391729119491NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3391730119491NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3391731119491NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3391732119491NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3391733119491NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506640000NoneNoneBuildingsAaralihatti HWC Electrical Work Slice-4366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391734119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3391735119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3391736119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3391737119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3391738119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3391739119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391740119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3391741119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3391742119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3391743119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3391744119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3391745119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3391746119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3391747119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3391748119492NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3391749119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3391750119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3391751119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3391752119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391753119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3391754119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3391755119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3391756119492NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3391757119492NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3391758119492NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3391759119492NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3391760119492NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3391761119492NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3391762119492NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3391763119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3391764119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3391765119492NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3391766119492NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3391767119492NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3391768119492NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3391769119492NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3391770119492NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3391771119492NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3391772119492NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3391773119492NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3391774119492NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3391775119492NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3391776119492NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3391777119492NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3391778119492NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3391779119492NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3391780119492NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3391781119492NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3391782119492None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3391783119492None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3391784119492None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3391785119492NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3391786119492NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3391787119492NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3391788119492NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3391789119492NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3391790119492NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3391791119492NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3391792119492NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3391793119492NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3391794119492NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3391795119492NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3391796119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3391797119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3391798119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3391799119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3391800119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3391801119492NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506640000NoneNoneBuildingsKohalli HWC GF Civil Work Slice-53606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391802119493NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3391803119493NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391804119493NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391805119493NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3391806119493NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3391807119493NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3391808119493NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3391809119493NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3391810119493NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3391811119493NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3391812119493NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3391813119493NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3391814119493NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3391815119493NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3391816119493NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3391817119493NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3391818119493NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3391819119493NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3391820119493NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3391821119493NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3391822119493NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3391823119493NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3391824119493NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3391825119493NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3391826119493NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3391827119493NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3391828119493NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3391829119493NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3391830119493NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3391831119493NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3391832119493NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3391833119493NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3391834119493NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3391835119493NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3391836119493NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3391837119493NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3391838119493NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3391839119493NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3391840119493NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3391841119493NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3391842119493NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3391843119493NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3391844119493NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3391845119493NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3391846119493NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3391847119493NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3391848119493NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3391849119493NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3391850119493NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3391851119493NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3391852119493NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3391853119493NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506640000NoneNoneBuildingsKohalli HWC FF Civil Work Slice-51768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391854119494NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3391855119494NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3391856119494NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3391857119494NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3391858119494NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3391859119494NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3391860119494NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3391861119494NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3391862119494NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3391863119494NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3391864119494NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3391865119494NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3391866119494NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3391867119494NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3391868119494NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3391869119494NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3391870119494NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3391871119494NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3391872119494NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3391873119494NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3391874119494NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3391875119494NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3391876119494NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3391877119494NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3391878119494NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3391879119494NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3391880119494NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3391881119494NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3391882119494NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3391883119494NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3391884119494NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3391885119494NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3391886119494NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3391887119494NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3391888119494NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3391889119494NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3391890119494NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3391891119494NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3391892119494NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506640000NoneNoneBuildingsKohalli HWC WS Work Slice-5233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391893119495NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3391894119495NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3391895119495NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3391896119495NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3391897119495NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3391898119495NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3391899119495NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3391900119495NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3391901119495NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3391902119495NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3391903119495NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3391904119495NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3391905119495NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3391906119495NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3391907119495NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3391908119495NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3391909119495NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3391910119495NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3391911119495NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3391912119495NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3391913119495NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3391914119495NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3391915119495NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3391916119495NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3391917119495NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3391918119495NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3391919119495NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3391920119495NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3391921119495NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506640000NoneNoneBuildingsKohalli HWC Electrical Work Slice-5366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391922119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3391923119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3391924119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3391925119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3391926119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3391927119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391928119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3391929119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3391930119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3391931119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3391932119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3391933119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3391934119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3391935119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3391936119496NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3391937119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3391938119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3391939119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3391940119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3391941119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3391942119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3391943119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3391944119496NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3391945119496NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3391946119496NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3391947119496NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3391948119496NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3391949119496NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3391950119496NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3391951119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3391952119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3391953119496NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3391954119496NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3391955119496NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3391956119496NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3391957119496NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3391958119496NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3391959119496NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3391960119496NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3391961119496NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3391962119496NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3391963119496NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3391964119496NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3391965119496NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3391966119496NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3391967119496NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3391968119496NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3391969119496NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3391970119496None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3391971119496None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3391972119496None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3391973119496NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3391974119496NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3391975119496NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3391976119496NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3391977119496NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3391978119496NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3391979119496NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3391980119496NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3391981119496NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3391982119496NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3391983119496NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3391984119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3391985119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3391986119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3391987119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3391988119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3391989119496NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506650000NoneNoneBuildingsBadli HWC GF Civil Work Slice-63606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3391990119497NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3391991119497NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3391992119497NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3391993119497NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3391994119497NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3391995119497NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3391996119497NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3391997119497NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3391998119497NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3391999119497NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3392000119497NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3392001119497NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3392002119497NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3392003119497NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3392004119497NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3392005119497NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3392006119497NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3392007119497NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3392008119497NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3392009119497NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3392010119497NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3392011119497NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3392012119497NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3392013119497NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3392014119497NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3392015119497NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3392016119497NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3392017119497NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3392018119497NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3392019119497NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3392020119497NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3392021119497NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3392022119497NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3392023119497NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3392024119497NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3392025119497NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3392026119497NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3392027119497NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3392028119497NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3392029119497NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3392030119497NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3392031119497NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3392032119497NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3392033119497NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3392034119497NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3392035119497NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3392036119497NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3392037119497NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3392038119497NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3392039119497NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3392040119497NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3392041119497NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506650000NoneNoneBuildingsBadli HWC FF Civil Work Slice-61768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392042119498NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3392043119498NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3392044119498NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3392045119498NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3392046119498NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3392047119498NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3392048119498NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3392049119498NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3392050119498NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3392051119498NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3392052119498NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3392053119498NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3392054119498NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3392055119498NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3392056119498NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3392057119498NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3392058119498NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3392059119498NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3392060119498NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3392061119498NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3392062119498NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3392063119498NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3392064119498NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3392065119498NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3392066119498NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3392067119498NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3392068119498NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3392069119498NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3392070119498NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3392071119498NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3392072119498NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3392073119498NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3392074119498NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3392075119498NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3392076119498NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3392077119498NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3392078119498NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3392079119498NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3392080119498NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506650000NoneNoneBuildingsBadli HWC WS Work Slice-6233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392081119499NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3392082119499NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3392083119499NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3392084119499NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3392085119499NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3392086119499NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3392087119499NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3392088119499NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3392089119499NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3392090119499NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3392091119499NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3392092119499NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3392093119499NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3392094119499NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3392095119499NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3392096119499NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3392097119499NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3392098119499NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3392099119499NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3392100119499NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3392101119499NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3392102119499NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3392103119499NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3392104119499NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3392105119499NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3392106119499NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3392107119499NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3392108119499NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3392109119499NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506650000NoneNoneBuildingsBadli HWC Electrical Work Slice-6366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392110119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3392111119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3392112119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3392113119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3392114119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3392115119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3392116119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3392117119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3392118119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3392119119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3392120119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3392121119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3392122119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3392123119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3392124119500NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3392125119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3392126119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3392127119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3392128119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3392129119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3392130119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3392131119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3392132119500NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3392133119500NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3392134119500NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3392135119500NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3392136119500NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3392137119500NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3392138119500NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3392139119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3392140119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3392141119500NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3392142119500NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3392143119500NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3392144119500NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3392145119500NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3392146119500NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3392147119500NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3392148119500NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3392149119500NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3392150119500NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3392151119500NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3392152119500NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3392153119500NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3392154119500NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3392155119500NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3392156119500NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3392157119500NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3392158119500None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3392159119500None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3392160119500None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3392161119500NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3392162119500NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3392163119500NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3392164119500NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3392165119500NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3392166119500NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3392167119500NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3392168119500NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3392169119500NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3392170119500NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3392171119500NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3392172119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3392173119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3392174119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3392175119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3392176119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3392177119500NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
17195506650000NoneNoneBuildingsChippalkatti HWC GF Civil Work Slice-73606159.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392178119501NoneCommon PWD SR 23-24 V-1 pg no 8 item no 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120.36120.36144.97FalseNoneNoneFalseNoneFalse17448.58920
3392179119501NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7067.027067.0218.38FalseNoneNoneFalseNoneFalse129891.82760
3392180119501NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8012.158012.1514.89FalseNoneNoneFalseNoneFalse119300.91350
3392181119501NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.2.1Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8160.538160.531.79FalseNoneNoneFalseNoneFalse14607.34870
3392182119501NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13299.7813299.787.14FalseNoneNoneFalseNoneFalse94960.42920
3392183119501NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, SLAB & STAIRCASE-GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11735.111735.130.15FalseNoneNoneFalseNoneFalse353813.2650
3392184119501NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS & LINTEL-GROUND ROOF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12517.4412517.4411.59FalseNoneNoneFalseNoneFalse145077.12960
3392185119501NoneCommon PWD SR 23-24 V-1 pg no 7 item no 1.91.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum313.88313.88180.15FalseNoneNoneFalseNoneFalse56545.4820
3392186119501NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7336.067336.063.02FalseNoneNoneFalseNoneFalse22154.90120
3392187119501NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11343.9311343.930.39FalseNoneNoneFalseNoneFalse4424.13270
3392188119501NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne105559.26105559.265.61FalseNoneNoneFalseNoneFalse592187.44860
3392189119501NoneCommon PWD SR 23-24 V-2 pg no 9 item no 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum6620.986620.988.06FalseNoneNoneFalseNoneFalse53365.09880
3392190119501NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum10471.3210471.3239.87FalseNoneNoneFalseNoneFalse417491.52840
3392191119501NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1218.941218.9443.65FalseNoneNoneFalseNoneFalse53206.7310
3392192119501NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum116601.7116601.70.47FalseNoneNoneFalseNoneFalse54802.7990
3392193119501NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1198.881198.887.0FalseNoneNoneFalseNoneFalse8392.160
3392194119501NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.059.036.0FalseNoneNoneFalseNoneFalse2124.00
3392195119501NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4598.464598.4617.01FalseNoneNoneFalseNoneFalse78219.80460
3392196119501NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7946.127946.1212.65FalseNoneNoneFalseNoneFalse100518.4180
3392197119501NoneCommon PWD SR 23-24 V-2 pg no 109 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6748.426748.421.32FalseNoneNoneFalseNoneFalse8907.91440
3392198119501NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg198.24198.24293.27FalseNoneNoneFalseNoneFalse58137.84480
3392199119501NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.24375.2419.8FalseNoneNoneFalseNoneFalse7429.7520
3392200119501NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2407.22407.26.3FalseNoneNoneFalseNoneFalse15165.360
3392201119501NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm323.32323.3285.98FalseNoneNoneFalseNoneFalse27799.05360
3392202119501NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm411.82411.82440.24FalseNoneNoneFalseNoneFalse181299.63680
3392203119501NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm118.0118.0526.22FalseNoneNoneFalseNoneFalse62093.960
3392204119501NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm437.78437.78297.7FalseNoneNoneFalseNoneFalse130327.1060
3392205119501NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm348.1348.138.41FalseNoneNoneFalseNoneFalse13370.5210
3392206119501NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm964.06964.0637.58FalseNoneNoneFalseNoneFalse36229.37480
3392207119501NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1351.11351.187.58FalseNoneNoneFalseNoneFalse118329.3380
3392208119501NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2909.882909.8823.96FalseNoneNoneFalseNoneFalse69720.72480
3392209119501NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1049.021049.0213.06FalseNoneNoneFalseNoneFalse13700.20120
3392210119501NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1642.561642.5638.41FalseNoneNoneFalseNoneFalse63090.72960
3392211119501NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1947.01947.05.65FalseNoneNoneFalseNoneFalse11000.550
3392212119501NoneCommon PWD SR 23-24 V-2 pg no 63 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5081.085081.089.16FalseNoneNoneFalseNoneFalse46542.69280
3392213119501NoneCommon PWD SR 23-24 V-2 pg no 83 item no 11.2811.28 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg666.7666.7160.0FalseNoneNoneFalseNoneFalse106672.00
3392214119501NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm149.86149.86440.24FalseNoneNoneFalseNoneFalse65974.36640
3392215119501NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm205.32205.32267.93FalseNoneNoneFalseNoneFalse55011.38760
3392216119501NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.059.013.97FalseNoneNoneFalseNoneFalse824.230
3392217119501NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm135.7135.713.97FalseNoneNoneFalseNoneFalse1895.7290
3392218119501NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.5462.5477.18FalseNoneNoneFalseNoneFalse4826.83720
3392219119501NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo279.66279.6626.0FalseNoneNoneFalseNoneFalse7271.160
3392220119501NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo141.6141.613.0FalseNoneNoneFalseNoneFalse1840.80
3392221119501NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1241.361241.3626.0FalseNoneNoneFalseNoneFalse32275.360
3392222119501NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo153.4153.426.0FalseNoneNoneFalseNoneFalse3988.40
3392223119501NoneCommon PWD SR 23-24 V-1 pg no 9 item no 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum501.5501.58.06FalseNoneNoneFalseNoneFalse4042.090
3392224119501NoneCommon PWD SR 23-24 V-1 pg no 17 item no 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including 20% for Centering and Shuttering. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9388.089388.086.05FalseNoneNoneFalseNoneFalse56797.8840
3392225119501NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm284.38284.386.0FalseNoneNoneFalseNoneFalse1706.280
3392226119501NoneCommon PWD SR 23-24 vol-2 pg no 41 item no 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm300.9300.930.0FalseNoneNoneFalseNoneFalse9027.00
3392227119501NoneCommon PWD SR 23-24 vol-2 pg no 136 item no 15.6Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4- 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm598.26598.2630.0FalseNoneNoneFalseNoneFalse17947.80
3392228119501NoneCommon PWD SR 23-24 vol-5 pg no 221 item no 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2315.162315.162.0FalseNoneNoneFalseNoneFalse4630.320
3392229119501NoneCommon PWD SR 23-24 V-2 pg no 188 item no 19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1181.181181.1842.12FalseNoneNoneFalseNoneFalse49751.30160
17195506650000NoneNoneBuildingsChippalkatti HWC FF Civil Work Slice-71768323.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392230119502NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13432.7813432.784.22FalseNoneNoneFalseNoneFalse56686.33160
3392231119502NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.615.94FalseNoneNoneFalseNoneFalse75097.10340
3392232119502NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC SLAB-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11852.4511852.456.82FalseNoneNoneFalseNoneFalse80833.7090
3392233119502NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS-FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12642.6112642.612.17FalseNoneNoneFalseNoneFalse27434.46370
3392234119502NoneCommon PWD SR 23-24 V-1 pg no 15 item no 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 using 20 mm nominal size graded crushed coarse aggregates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7409.427409.421.03FalseNoneNoneFalseNoneFalse7631.70260
3392235119502NoneCommon PWD SR 23-24 V-1 pg no 16 item no 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11457.3711457.370.46FalseNoneNoneFalseNoneFalse5270.39020
3392236119502NoneCommon PWD SR 23-24 V-1 pg no 18 item no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne106614.85106614.851.63FalseNoneNoneFalseNoneFalse173782.20550
3392237119502NoneCommon PWD SR 23-24 V-2 pg no 13 item no 6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm12356.1612356.1635.16FalseNoneNoneFalseNoneFalse434442.58560
3392238119502NoneCommon PWD SR 23-24 V-2 pg no 14 item no 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1438.351438.3542.38FalseNoneNoneFalseNoneFalse60957.2730
3392239119502NoneCommon PWD SR 23-24 V-2 pg no 100 item no 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum117767.72117767.720.21FalseNoneNoneFalseNoneFalse24731.22120
3392240119502NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.5112.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1210.871210.874.0FalseNoneNoneFalseNoneFalse4843.480
3392241119502NoneCommon PWD SR 23-24 V-2 pg no A-25 item no 444Hold fasts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo59.659.624.0FalseNoneNoneFalseNoneFalse1430.40
3392242119502NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.35 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4644.444644.449.12FalseNoneNoneFalseNoneFalse42357.29280
3392243119502NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.912.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8025.588025.5810.55FalseNoneNoneFalseNoneFalse84669.8690
3392244119502NoneCommon PWD SR 23-24 V-2 pg no 110 item no 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6815.96815.90.72FalseNoneNoneFalseNoneFalse4907.4480
3392245119502NoneCommon PWD SR 23-24 V-2 pg no 86 item no 11.34A11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg200.22200.22236.57FalseNoneNoneFalseNoneFalse47366.04540
3392246119502NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem378.99378.999.9FalseNoneNoneFalseNoneFalse3752.0010
3392247119502NoneCommon PWD SR 23-24 V-2 pg no 104 item no 12.55.2Solid panel prelam pvc door shutter. Providing and fixing 30mm thick factory made rigid foam Prelam panelled Door Shutters made from M.S. Tube of 19x19mm, 19 guage for styles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm. Aluminium hinges. with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2436.042436.043.15FalseNoneNoneFalseNoneFalse7673.5260
3392248119502NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm384.95384.9568.7FalseNoneNoneFalseNoneFalse26446.0650
3392249119502NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm415.94415.94240.55FalseNoneNoneFalseNoneFalse100054.3670
3392250119502NoneCommon PWD SR 23-24 V-2 pg no 50 item no 8.518.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm119.18119.18309.26FalseNoneNoneFalseNoneFalse36857.60680
3392251119502NoneCommon PWD SR 23-24 V-2 pg no 42 item no 8.88.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Out side) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm442.16442.16204.47FalseNoneNoneFalseNoneFalse90408.45520
3392252119502NoneCommon PWD SR 23-24 V-2 pg no 41 item no 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm351.58351.5827.87FalseNoneNoneFalseNoneFalse9798.53460
3392253119502NoneCommon PWD SR 23-24 V-2 pg no 149 item no 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm973.7973.776.26FalseNoneNoneFalseNoneFalse74254.3620
3392254119502NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1364.611364.6155.67FalseNoneNoneFalseNoneFalse75967.83870
3392255119502NoneCommon PWD SR 23-24 V-2 pg no 60 item no 9.119.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1059.511059.515.98FalseNoneNoneFalseNoneFalse6335.86980
3392256119502NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.389.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1658.991658.9927.87FalseNoneNoneFalseNoneFalse46236.05130
3392257119502NoneCommon PWD SR 23-24 V-2 pg no 65 item no 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1966.471966.475.65FalseNoneNoneFalseNoneFalse11110.55550
3392258119502NoneCommon PWD SR 23-24 V-2 pg no 64 item no 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5131.95131.99.8FalseNoneNoneFalseNoneFalse50292.620
3392259119502NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm151.36151.36240.55FalseNoneNoneFalseNoneFalse36409.6480
3392260119502NoneCommon PWD SR 23-24 V-2 pg no 46 item no 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm207.37207.37184.02FalseNoneNoneFalseNoneFalse38160.22740
3392261119502NoneCommon PWD SR 23-24 V-2 pg no 45 item no 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm337.28337.2821.25FalseNoneNoneFalseNoneFalse7167.20
3392262119502NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm59.5959.5911.27FalseNoneNoneFalseNoneFalse671.57930
3392263119502NoneCommon PWD SR 23-24 V-2 pg no 48 item no 8.48.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm137.06137.0611.27FalseNoneNoneFalseNoneFalse1544.66620
3392264119502NoneCommon PWD SR 23-24 V-2 pg no 47 item no 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm63.1763.1721.89FalseNoneNoneFalseNoneFalse1382.79130
3392265119502NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo282.46282.4610.0FalseNoneNoneFalseNoneFalse2824.60
3392266119502NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo143.02143.025.0FalseNoneNoneFalseNoneFalse715.10
3392267119502NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1253.781253.785.0FalseNoneNoneFalseNoneFalse6268.90
3392268119502NoneCommon PWD SR 23-24 V-2 pg no 105 item no 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo154.93154.9310.0FalseNoneNoneFalseNoneFalse1549.30
17195506650000NoneNoneBuildingsChippalkatti HWC WS Work Slice-7233651.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392269119503NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7052.867052.862.0FalseNoneNoneFalseNoneFalse14105.720
3392270119503NoneCommon PWD SR 23-24 V-2 pg no 131 item no 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5763.125763.122.0FalseNoneNoneFalseNoneFalse11526.240
3392271119503NoneCommon PWD SR 23-24 V-2 pg no 133 item no 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4853.344853.342.0FalseNoneNoneFalseNoneFalse9706.680
3392272119503NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach955.8955.82.0FalseNoneNoneFalseNoneFalse1911.60
3392273119503NoneCommon PWD SR 23-24 V-2 pg no 135 item no 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6563.166563.162.0FalseNoneNoneFalseNoneFalse13126.320
3392274119503NoneCommonPWD SR 23-24 V-2 pg no 133 item no 14.10.1.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6363.746363.741.0FalseNoneNoneFalseNoneFalse6363.740
3392275119503NoneCommon PWD SR 23-24 V-2 pg no 136 item no 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach55.4655.467.0FalseNoneNoneFalseNoneFalse388.220
3392276119503NoneCommon PWD SR 23-24 V-2 pg no 127 item no 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3392277119503NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.74109.745.0FalseNoneNoneFalseNoneFalse548.70
3392278119503NoneCommon PWD SR 23-24 V-2 pg no 137 item no 14.40.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach564.04564.042.0FalseNoneNoneFalseNoneFalse1128.080
3392279119503NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo172.28172.282.0FalseNoneNoneFalseNoneFalse344.560
3392280119503NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 75 mm dia, 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem259.6259.615.0FalseNoneNoneFalseNoneFalse3894.00
3392281119503NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 90 mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem346.92346.9210.0FalseNoneNoneFalseNoneFalse3469.20
3392282119503NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 110mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem484.98484.988.0FalseNoneNoneFalseNoneFalse3879.840
3392283119503NoneCommon PWD SR 23-24 V-5 pg no 113 item no 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 140mm dia,6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem689.12689.1218.0FalseNoneNoneFalseNoneFalse12404.160
3392284119503NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.62364.6220.0FalseNoneNoneFalseNoneFalse7292.40
3392285119503NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3392286119503NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem195.88195.8835.0FalseNoneNoneFalseNoneFalse6855.80
3392287119503NoneCommon PWD SR 23-24 V-2 pg no 122 item no 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem349.28349.2830.0FalseNoneNoneFalseNoneFalse10478.40
3392288119503NoneCommon PWD SR 23-24 V-2 pg no 123 item no 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem562.86562.8620.0FalseNoneNoneFalseNoneFalse11257.20
3392289119503NoneCommon PWD SR 23-24 V-2 pg no 125 item no 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem343.38343.3840.0FalseNoneNoneFalseNoneFalse13735.20
3392290119503NoneCommon PWD SR 23-24 V-2 pg no 120 item no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.6210.624500.0FalseNoneNoneFalseNoneFalse47790.00
3392291119503NoneCommon PWD SR 23-24 V-5 pg no 191 item no 16.9Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6435.726435.723.0FalseNoneNoneFalseNoneFalse19307.160
3392292119503NoneCommon PWD SR 23-24 V-2 pg no A-16 item no 166C.P. Brass stop cock (concealed) 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo619.5619.512.0FalseNoneNoneFalseNoneFalse7434.00
3392293119503NoneCommon PWD SR 23-24 V-2 pg no A-15 item no 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo442.5442.52.0FalseNoneNoneFalseNoneFalse885.00
3392294119503NoneCommon PWD SR 23-24 V-2 pg no 116 item no 13.2.1Brass bib-cock 15 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.48337.483.0FalseNoneNoneFalseNoneFalse1012.440
3392295119503NoneCommonPWD SR 23-24 V-2 pg no 136 item no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem108.56108.5615.0FalseNoneNoneFalseNoneFalse1628.40
3392296119503NoneCommon PWD SR 23-24 V-2 pg no 121 item no 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1585.921585.922.0FalseNoneNoneFalseNoneFalse3171.840
3392297119503NoneCommon PWD SR 23-24 V-5 pg no 149 item no 13.4.1Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete,. 0.50 HP/0.37kW - 5 STG stage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12000.612000.61.0FalseNoneNoneFalseNoneFalse12000.60
17195506650000NoneNoneBuildingsChippalkatti HWC Electrical Work Slice-7366131.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3392298119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint317.42317.4218.0FalseNoneNoneFalseNoneFalse5713.560
3392299119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3392300119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3392301119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3392302119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 3 way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3392303119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3392304119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3392305119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3392306119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3392307119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3392308119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.98189.982.0FalseNoneNoneFalseNoneFalse379.960
3392309119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3392310119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3392311119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3392312119504NoneCommon PWD SR 23-24 V-6 pg no 8 item no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3392313119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
3392314119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3392315119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3392316119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3392317119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3392318119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3392319119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3392320119504NoneCommon PWD SR 23-24 V-6 pg no 9 item no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3392321119504NoneCommon PWD SR 23-24 V-6 pg no 48 item no 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3392322119504NoneCommon PWD SR 23-24 V-6 pg no 4 item no 1.13Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3392323119504NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2). 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem77.8877.88165.0FalseNoneNoneFalseNoneFalse12850.20
3392324119504NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2).25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem92.0492.04120.0FalseNoneNoneFalseNoneFalse11044.80
3392325119504NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem80.2480.24165.0FalseNoneNoneFalseNoneFalse13239.60
3392326119504NoneCommon PWD SR 23-24 V-6 pg no 2 item no 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem93.2293.22120.0FalseNoneNoneFalseNoneFalse11186.40
3392327119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments.1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem30.6830.68350.0FalseNoneNoneFalseNoneFalse10738.00
3392328119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem49.5649.56450.0FalseNoneNoneFalseNoneFalse22302.00
3392329119504NoneCommon PWD SR 23-24 V-6 pg no 5 item no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latestamendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem74.3474.34190.0FalseNoneNoneFalseNoneFalse14124.60
3392330119504NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
3392331119504NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3392332119504NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.20.1Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. Board. 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5046.865046.862.0FalseNoneNoneFalseNoneFalse10093.720
3392333119504NoneCommon PWD SR 23-24 V-6 pg no 43 item no 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3392334119504NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3392335119504NoneCommon PWD SR 23-24 V-6 pg no 47 item no 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach502.68502.686.0FalseNoneNoneFalseNoneFalse3016.080
3392336119504NoneCommon PWD SR 23-24 V-6 pg no 50 item no 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo61.3661.362.0FalseNoneNoneFalseNoneFalse122.720
3392337119504NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3392338119504NoneCommon PWD SR 23-24 V-6 pg no 30 item no 6.3.1Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3392339119504NoneCommon PWD SR 23-24 V-6 pg no 52 item no 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach74.3474.3422.0FalseNoneNoneFalseNoneFalse1635.480
3392340119504NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3392341119504NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3392342119504NoneCommon PWD SR 23-24 V-6 pg no 57 item no 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach834.26834.263.0FalseNoneNoneFalseNoneFalse2502.780
3392343119504NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3392344119504NoneCommon PWD SR 23-24 V-6 pg no 13 item no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmm ( 12 GI Strips -4 X 0.8 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm164667.82164667.820.065FalseNoneNoneFalseNoneFalse10703.40830
3392345119504NoneCommon PWD SR 23-24 V-6 pg no 52 item no 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm24645.4824645.480.065FalseNoneNoneFalseNoneFalse1601.95620
3392346119504None19-20 SR item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19-20 SR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.96143.9610.0FalseNoneNoneFalseNoneFalse1439.60
3392347119504None19-20 SR item no 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes .10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.449.448.0FalseNoneNoneFalseNoneFalse75.520
3392348119504None21-22 SR BSR item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed-In ordinary soil ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargecm306.8306.830.0FalseNoneNoneFalseNoneFalse9204.00
3392349119504NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.590.5960000.0FalseNoneNoneFalseNoneFalse35400.00
3392350119504NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5245.15245.11.5FalseNoneNoneFalseNoneFalse7867.650
3392351119504NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem654.9654.95.0FalseNoneNoneFalseNoneFalse3274.50
3392352119504NoneCommon PWD SR 23-24 V-6 pg no 56 item no 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach191.16191.162.0FalseNoneNoneFalseNoneFalse382.320
3392353119504NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3392354119504NoneCommon PWD SR 23-24 V-6 pg no 20 item no 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem892.08892.082.0FalseNoneNoneFalseNoneFalse1784.160
3392355119504NoneCommon PWD SR 23-24 V-6 pg no 17 item no 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3392356119504NoneCommon PWD SR 23-24 V-6 pg no 18 item no 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3392357119504NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.38284.383.0FalseNoneNoneFalseNoneFalse853.140
3392358119504NoneCommon PWD SR 23-24 V-6 pg no 14 item no 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach473.18473.181.0FalseNoneNoneFalseNoneFalse473.180
3392359119504NoneCommon PWD SR 23-24 V-6 pg no 15 item no 5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach8119.588119.581.0FalseNoneNoneFalseNoneFalse8119.580
3392360119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3392361119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3392362119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.29Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3392363119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3392364119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3392365119504NoneCommon PWD SR 23-24 V-6 pg no 19 item no 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1628.41628.42.0FalseNoneNoneFalseNoneFalse3256.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17195506650000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17195506650000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17195506650001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17195506650000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17195506650000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17195533440000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17195533570000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17195533690000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17195533890000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17195534050000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17195534220000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17195534410000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17195534620000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17195534750000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17195534890000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17195535080000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17195535260000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17195535410000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17195535570000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17195535700000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17195535820000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17195535950000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17195536060000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22 , 2022-23 & 2023-24None
17195536180000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
17195579570000NoneNoneELIGIBILITYThe rates for concrete works inclusive of Form worksNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.211.60 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.12.90 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.8.50 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the worksPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitments and on-going works
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation -870.00 Cum,2)RCC and PCC -700.00 Cum 3)Steel Reinforcement for RCC work- 42.25 Tonnes 4)BBM/Cement concrete Block Masonry/Solid Block Masonry/-2800.00 Sqm 5)Flooring/Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing) -1500.00 Sqm, 6)Plastering-7500.00 Sqm,7)Painting -7200.00 Sqm (8)MS grill- 2900.00 Kg, 9)WPC - 800.00 sqm, Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1 Min 10 cft capacity Concrete Mixer-3 Nos. 2. Centering sheets-500 sqmtr 3.Tipper-1 Nos 4.Water tanker-1 No 5.Bar, Bending and cutting machine 1 NoPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax invoice & receipt
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.127.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime ContractorPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneKPWD Class-II & above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No,Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -2 Two No 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working inpermanent role of the organization for at least two years-1 One No. Degree certificate and Experience Certificate to be furnishedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.846.40 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Turnover Certificate Profit & Loss Certificate issued and duly certified by the charted accountant
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
KPWD Class-II & above Registration certificate issued by Chief Engineer PWDTrueTechnical Bid
Workdone certificate issued by the Officer not below the rank of Executive EngineerTrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their name.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.rtificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719558164000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone