| 1719631680000 | 0 | None | None | Other Works | sinking of borewell and fixing of motor and construction of cistern near ravup bilawar house construction of septic tank behind yuvaraj rajaput house and development of choukimath near afzalpur road | 697915.45 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3405847 | 120250 | None | code01 | Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2023-24 P No. 139 It No 12.1.1,12. 1.2,12. 1.3)0 to 50 mtr depth | Mtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | | 3405848 | 120250 | None | code02 | Above 50 mtr upto 100 mtr | Mtr | 574.89 | 574.89 | 35.0 | False | None | None | False | None | False | 20121.15 | 0 | | 3405849 | 120250 | None | code03 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing5.10kg/m.prices include Collar-Medium duty. Providing 160 mm casing pipe with M.S. coller (BWSSB SR 2023-24 P No. 134 It No 12.32) | Mtr | 2394.98 | 2394.98 | 6.0 | False | None | None | False | None | False | 14369.88 | 0 | | 3405850 | 120250 | None | code04 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer Providing 200mm PVC casing cap including fixing charges (BWSSB SR 2021-22 P No. 134 It No 12.34) | No | 203.19 | 203.19 | 1.0 | False | None | None | False | None | False | 203.19 | 0 | | 3405851 | 120250 | None | code05 | Geophysical Investigation of site for sinking Borewell Geophysical Investigation of site for sinking Borewell for supplying drinking water to the habitation either through a hand pump, Mini Water Supply scheme, or Piped Water Supply Scheme by vertical electrical sounding by adopting venner or Schlumberger's method, including reconnaissance survey of geological formation, geophysical investigation of existing ground water in the vicinity, its quality, quantity & acceptability of the users indicating the location of site, recommended depth of casing pipe required to seal the top unconsolidated formation incluing an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instrument and accessories to work site, engaging technical personal and labour required etc., complete.(BWSSB SR 2023-24 P No. 151 It No 12.4) | No | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | | 3405852 | 120250 | None | code06 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.5.00 HP/1.5KW 12 STG .(BWSSB SR 2023-24 P No. 150 It No 13.7.5) (H.P -1. 5 / 3.7KW Stage 15 Head 100.00 Mtr) | Set | 20988.66 | 20988.66 | 1.0 | False | None | None | False | None | False | 20988.66 | 0 | | 3405853 | 120250 | None | code07 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Upto 3 HP pumps (BWSSB SR 2023-24 P No. 154 It No 13.23.1) | Set | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | | 3405854 | 120250 | None | code08 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm dia
m 63 mm dia.(BWSSB SR 2023-24 P No. 95 It No 9.1.1) | Mtr | 234.17 | 234.17 | 65.0 | False | None | None | False | None | False | 15221.05 | 0 | | 3405855 | 120250 | None | code09 | SubmersibleCable: Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 Sqm.(BWSSB SR 2023-24 P No. 154 It No 13.22.3) | Mtr | 167.26 | 167.26 | 75.0 | False | None | None | False | None | False | 12544.5 | 0 | | 3405856 | 120250 | None | code10 | Pressure Guage: Supply and Delevery of brand new best make pressure guage (Bourdon Type size confirming to IS 3624/87 with latest amendments with ISI mark as provided in SPD rate contract. .(BWSSB SR 2023-24 P No. 154 It No 13.23.1) | No | 515.42 | 515.42 | 1.0 | False | None | None | False | None | False | 515.42 | 0 | | 3405857 | 120250 | None | code11 | Supply and delivery best indegeneous brand new power capacitor as per IS 283/86 with latest amendments with ISI mark of required capacity tested and approved by one KEB aouthorities and erection. Electrification and commissioning of the same at the location of the respective pumpsets as provided in SPD rate contract . (BWSSB SR 2023-24 P No. 151 It No 13.25) | Kvar | 681.45 | 681.45 | 1.0 | False | None | None | False | None | False | 681.45 | 0 | | 3405858 | 120250 | None | code12 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(BWSSB SR 2023-24 P No. 155 It No 13.26) Per 3 polse | No | 1424.85 | 1424.85 | 1.0 | False | None | None | False | None | False | 1424.85 | 0 | | 3405859 | 120250 | None | code13 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(BWSSB SR 2023-24 P No. 156 It No 13.33) | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | | 3405860 | 120250 | None | code14 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit..(BWSSB SR 2023-24 P No. 156 It No 13.36) | Mtr | 167.26 | 167.26 | 40.0 | False | None | None | False | None | False | 6690.4 | 0 | | 3405861 | 120250 | None | code15 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2023-24 P No. 157 It No 13.39) | Job | 4646.25 | 4646.25 | 1.0 | False | None | None | False | None | False | 4646.25 | 0 | | 3405862 | 120250 | None | code16 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 65 mm dia non return valve (BWSSB SR 2023-24 P No. 154 It No 13.25.2) | Each | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | | 3405863 | 120250 | None | code17 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2023-24 P No. 156 It No 13.32) | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | | 3405864 | 120250 | None | code18 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m | Cum | 299.83 | 299.83 | 31.5 | False | None | None | False | None | False | 9444.645 | 0 | | 3405865 | 120250 | None | code19 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.1 | False | None | None | False | None | False | 15582.777 | 0 | | 3405866 | 120250 | None | code20 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7834.19 | 7834.19 | 2.41 | False | None | None | False | None | False | 18880.3979 | 0 | | 3405867 | 120250 | None | code21 | Form Work As per recommendations of Technical working group,
rates for formwork shall be added on percentage basis to the finished concrete item rate. For drain form works consider 35% | Cum | 2741.96 | 2741.96 | 2.41 | False | None | None | False | None | False | 6608.1236 | 0 | | 3405868 | 120250 | None | code22 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
All other type of structures | Tonne | 97894.62 | 97894.62 | 0.229 | False | None | None | False | None | False | 22417.86798 | 0 | | 3405869 | 120250 | None | code23 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1
cement : 6 coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges complete as
per the direction of engineer incharge of work. | Cum | 9884.74 | 9884.74 | 9.81 | False | None | None | False | None | False | 96969.2994 | 0 | | 3405870 | 120250 | None | code24 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 315.94 | 315.94 | 61.64 | False | None | None | False | None | False | 19474.5416 | 0 | | 3405871 | 120250 | None | code25 | Construction of Subgrade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (PWD DSR 2023-24 Vol 3 P. No. 15 It No. 3.6 ) | Sqm | 610.82 | 610.82 | 8.25 | False | None | None | False | None | False | 5039.265 | 0 | | 3405872 | 120250 | None | code26 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be
paid separately as per relevant technical specification) | Sqm | 1438.47 | 1438.47 | 33.0 | False | None | None | False | None | False | 47469.51 | 0 | | 3405873 | 120250 | None | code27 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m | Cum | 299.83 | 299.83 | 18.14 | False | None | None | False | None | False | 5438.9162 | 0 | | 3405874 | 120250 | None | code28 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 5.02 | False | None | None | False | None | False | 37250.2574 | 0 | | 3405875 | 120250 | None | code29 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7834.19 | 7834.19 | 4.92 | False | None | None | False | None | False | 38544.2148 | 0 | | 3405876 | 120250 | None | code30 | Form Work As per recommendations of Technical working group,
rates for formwork shall be added on percentage basis to the finished concrete item rate. For drain form works consider 35% | Cum | 2741.96 | 2741.96 | 4.92 | False | None | None | False | None | False | 13490.4432 | 0 | | 3405877 | 120250 | None | code31 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
All other type of structures | Tonne | 97894.62 | 97894.62 | 0.467 | False | None | None | False | None | False | 45716.78754 | 0 | | 3405878 | 120250 | None | code32 | Providing & fixing corrugated G.S. sheet roofing including vertical /
curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel primer
and two coats of approved paint on overlapping of sheets complete as
per design drawings (up to any pitch in horizontal/ vertical or curved
surfaces), excluding the cost of purlins, rafters and trusses and including
cutting to size and shape wherever required as per the direction of
Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 1089.08 | 1089.08 | 84.0 | False | None | None | False | None | False | 91482.72 | 0 | | 3405879 | 120250 | None | code33 | Providing and fixing Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kg | 182.13 | 182.13 | 425.66 | False | None | None | False | None | False | 77525.4558 | 0 |
|