| 3405938 | 120253 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth (PWD SR 2023-24 Vol- 1 P no -6 Item No : 1.5.1) | Cum | 370.46 | 370.46 | 1.7339 | False | None | None | False | None | False | 642.340594 | 0 |
| 3405939 | 120253 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol- 1 P no -15 Item No : 2.1.3) | Cum | 7420.37 | 7420.37 | 0.289 | False | None | None | False | None | False | 2144.48693 | 0 |
| 3405940 | 120253 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2023-24 Vol- 2 P no -09 Item No : 5.1.1 | Cum | 6952.02 | 6952.02 | 3.375 | False | None | None | False | None | False | 23463.0675 | 0 |
| 3405941 | 120253 | None | code04 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm PWD SR 2023-24 Vol- 5 P no -116 Item No : 10.6 M 070A | Each | 20320.83 | 20320.83 | 1.0 | False | None | None | False | None | False | 20320.83 | 0 |
| 3405942 | 120253 | None | code05 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. (PWD SR 2023-24 Vol- 5 P no -116 Item No : 10.7 M 080A) | Each | 2331.79 | 2331.79 | 1.0 | False | None | None | False | None | False | 2331.79 | 0 |
| 3405943 | 120253 | None | code06 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 32mm dia (PWD SR 2023-24 Vol- 5 P no -127 Item No : 11.2.4 N 010D) | m | 472.05 | 472.05 | 6.0 | False | None | None | False | None | False | 2832.3 | 0 |
| 3405944 | 120253 | None | code07 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol- 2 P no -41 Item No : 8.1.2) | Sqm | 298.59 | 298.59 | 5.0296 | False | None | None | False | None | False | 1501.788264 | 0 |
| 3405945 | 120253 | None | code08 | Finishing walls with water proofing cement paint of required shade : Old work (one coats @ 2.20 kg/10 m²) complete. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol- 2 P no -53 Item No : 8.72.2) | Sqm | 69.38 | 69.38 | 15.6556 | False | None | None | False | None | False | 1086.185528 | 0 |
| 3405946 | 120253 | None | code09 | Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2023-24 P No. 139 It No 12.1.1,12. 1.2,12. 1.3)0 to 50 mtr depth | Mtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 |
| 3405947 | 120253 | None | code10 | Above 50 mtr upto 100 mtr | Mtr | 574.89 | 574.89 | 50.0 | False | None | None | False | None | False | 28744.5 | 0 |
| 3405948 | 120253 | None | code11 | Above 100 mtr upto 150 mtr | Mtr | 610.82 | 610.82 | 20.0 | False | None | None | False | None | False | 12216.4 | 0 |
| 3405949 | 120253 | None | code12 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing5.10kg/m.prices include Collar-Medium duty. Providing 160 mm casing pipe with M.S. coller (BWSSB SR 2023-24 P No. 134 It No 12.32) | Mtr | 2394.98 | 2394.98 | 12.0 | False | None | None | False | None | False | 28739.76 | 0 |
| 3405950 | 120253 | None | code13 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer Providing 200mm PVC casing cap including fixing charges (BWSSB SR 2021-22 P No. 134 It No 12.34) | No | 203.19 | 203.19 | 1.0 | False | None | None | False | None | False | 203.19 | 0 |
| 3405951 | 120253 | None | code14 | Geophysical Investigation of site for sinking Borewell Geophysical Investigation of site for sinking Borewell for supplying drinking water to the habitation either through a hand pump, Mini Water Supply scheme, or Piped Water Supply Scheme by vertical electrical sounding by adopting venner or Schlumberger's method, including reconnaissance survey of geological formation, geophysical investigation of existing ground water in the vicinity, its quality, quantity & acceptability of the users indicating the location of site, recommended depth of casing pipe required to seal the top unconsolidated formation incluing an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instrument and accessories to work site, engaging technical personal and labour required etc., complete.(BWSSB SR 2023-24 P No. 151 It No 12.4) | No | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 |
| 3405952 | 120253 | None | code15 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.5.00 HP/1.5KW 12 STG .(BWSSB SR 2023-24 P No. 150 It No 13.7.5) (H.P -1. 5 / 3.7KW Stage 15 Head 100.00 Mtr) | Set | 20988.66 | 20988.66 | 1.0 | False | None | None | False | None | False | 20988.66 | 0 |
| 3405953 | 120253 | None | code16 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Upto 3 HP pumps (BWSSB SR 2023-24 P No. 154 It No 13.23.1) | Set | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 |
| 3405954 | 120253 | None | code17 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm dia
m 63 mm dia.(BWSSB SR 2023-24 P No. 95 It No 9.1.1) | Mtr | 234.17 | 234.17 | 85.0 | False | None | None | False | None | False | 19904.45 | 0 |
| 3405955 | 120253 | None | code18 | SubmersibleCable: Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 Sqm.(BWSSB SR 2023-24 P No. 154 It No 13.22.3) | Mtr | 167.26 | 167.26 | 100.0 | False | None | None | False | None | False | 16726.0 | 0 |
| 3405956 | 120253 | None | code19 | Pressure Guage: Supply and Delevery of brand new best make pressure guage (Bourdon Type size confirming to IS 3624/87 with latest amendments with ISI mark as provided in SPD rate contract. .(BWSSB SR 2023-24 P No. 154 It No 13.23.1) | No | 515.42 | 515.42 | 1.0 | False | None | None | False | None | False | 515.42 | 0 |
| 3405957 | 120253 | None | code20 | Supply and delivery best indegeneous brand new power capacitor as per IS 283/86 with latest amendments with ISI mark of required capacity tested and approved by one KEB aouthorities and erection. Electrification and commissioning of the same at the location of the respective pumpsets as provided in SPD rate contract . (BWSSB SR 2023-24 P No. 151 It No 13.25) | Kvar | 681.45 | 681.45 | 1.0 | False | None | None | False | None | False | 681.45 | 0 |
| 3405958 | 120253 | None | code21 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(BWSSB SR 2023-24 P No. 155 It No 13.26) Per 3 polse | No | 1424.85 | 1424.85 | 1.0 | False | None | None | False | None | False | 1424.85 | 0 |
| 3405959 | 120253 | None | code22 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(BWSSB SR 2023-24 P No. 156 It No 13.33) | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 |
| 3405960 | 120253 | None | code23 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit..(BWSSB SR 2023-24 P No. 156 It No 13.36) | Mtr | 167.26 | 167.26 | 40.0 | False | None | None | False | None | False | 6690.4 | 0 |
| 3405961 | 120253 | None | code24 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2023-24 P No. 157 It No 13.39) | Job | 4646.25 | 4646.25 | 1.0 | False | None | None | False | None | False | 4646.25 | 0 |
| 3405962 | 120253 | None | code25 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 65 mm dia non return valve (BWSSB SR 2023-24 P No. 154 It No 13.25.2) | Each | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 |
| 3405963 | 120253 | None | code26 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2023-24 P No. 156 It No 13.32) | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 |
| 3405964 | 120253 | None | code27 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs | Cum | 126.37 | 126.37 | 18.081 | False | None | None | False | None | False | 2284.89597 | 0 |
| 3405965 | 120253 | None | code28 | Construction of rock fill embankment with all lifts and lead Construction of rock fill embankment with broken hard rock fragments of size not exceeding 300 mm laid in layers not exceeding 500 mm thick including filling of surface voids with stone spalls, blinding top layer with granular material, rolled with vibratory road roller, all complete as per clause 313. | Cum | 180.89 | 180.89 | 3.969 | False | None | None | False | None | False | 717.95241 | 0 |
| 3405966 | 120253 | None | code29 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.764 | False | None | None | False | None | False | 13089.53268 | 0 |
| 3405967 | 120253 | None | code30 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Refer Appendix-I For Formwork, Centering, Scaffolding of other type Footing is 3% (Pg No 115 of Common SR 2021-22) | Cum | 8214.57 | 8214.57 | 4.86 | False | None | None | False | None | False | 39922.8102 | 0 |
| 3405968 | 120253 | None | code31 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Refer Appendix-I For Formwork, Centering, Scaffolding of Columns is 70% (Pg No 115 of Common SR 2021-22) | Cum | 8214.57 | 8214.57 | 1.92 | False | None | None | False | None | False | 15771.9744 | 0 |
| 3405969 | 120253 | None | code32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 107090.48 | 107090.48 | 0.6102 | False | None | None | False | None | False | 65346.610896 | 0 |
| 3405970 | 120253 | None | code33 | Fabrication, Supplying, Erection, Testing and Commissioning of ...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top
section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete.(excluding foundation) as per technical data. 12 m/12.5 m - Top 100 mm and Bottom 310 mm dia | Each | 162309.0 | 162309.0 | 1.0 | False | None | None | False | None | False | 162309.0 | 0 |
| 3405971 | 120253 | None | code34 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia LED Floodlight 180W | Each | 19159.89 | 19159.89 | 8.0 | False | None | None | False | None | False | 153279.12 | 0 |
| 3405972 | 120253 | None | code35 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements,
including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended.
10 m - Top 75 mm and Bottom 165 mm dia | Each | 29859.9 | 29859.9 | 1.0 | False | None | None | False | None | False | 29859.9 | 0 |
| 3405973 | 120253 | None | code36 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia LED Floodlight 70W | Each | 11753.15 | 11753.15 | 6.0 | False | None | None | False | None | False | 70518.9 | 0 |
| 3405974 | 120253 | None | code37 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 200.71 | 200.71 | 16.0 | False | None | None | False | None | False | 3211.36 | 0 |
| 3405975 | 120253 | None | code38 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 | Mtr | 337.0 | 337.0 | 105.0 | False | None | None | False | None | False | 35385.0 | 0 |
| 3405976 | 120253 | None | code39 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694 2010 | Mtr | 242.84 | 242.84 | 105.0 | False | None | None | False | None | False | 25498.2 | 0 |
| 3405977 | 120253 | None | code40 | Fabricating supplying and mounting MS box made out… SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer pain and finally finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete-14 SWG | Sqm | 0.62 | 0.62 | 4000.0 | False | None | None | False | None | False | 2480.0 | 0 |
| 3405978 | 120253 | None | code41 | Extra length of GI pipe of class B 19mm dia for down rod. | Mtr | 244.08 | 244.08 | 80.0 | False | None | None | False | None | False | 19526.4 | 0 |
| 3405979 | 120253 | None | code42 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers .63 A | Each | 194.52 | 194.52 | 6.0 | False | None | None | False | None | False | 1167.12 | 0 |
| 3405980 | 120253 | None | code43 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DP | Each | 1365.37 | 1365.37 | 2.0 | False | None | None | False | None | False | 2730.74 | 0 |
| 3405981 | 120253 | None | code44 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary\ bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.60 to 70 A | Each | 7581.44 | 7581.44 | 2.0 | False | None | None | False | None | False | 15162.88 | 0 |
| 3405982 | 120253 | None | code45 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. | Each | 2868.28 | 2868.28 | 2.0 | False | None | None | False | None | False | 5736.56 | 0 |
| 3405983 | 120253 | None | code46 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. | Each | 6000.47 | 6000.47 | 2.0 | False | None | None | False | None | False | 12000.94 | 0 |
| 3405984 | 120253 | None | code47 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40 x 40 x 6 mm | Mtr | 377.89 | 377.89 | 8.0 | False | None | None | False | None | False | 3023.12 | 0 |
| 3405985 | 120253 | None | code48 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 638.08 | 638.08 | 6.0 | False | None | None | False | None | False | 3828.48 | 0 |
| 3405986 | 120253 | None | code49 | Chemical earthing for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achiveing ohmic value less than one ohm, Using 6ft. Copper bonded rod with backfill compound | LS | 7718.97 | 7718.97 | 2.0 | False | None | None | False | None | False | 15437.94 | 0 |