| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1719575878000 | 0 | None | None | Water supply/sewage lines | Providing and installing of 3phase motor pump set in near pump house and in wno.04 under tmc ugarkhurd limit. | 509151.3 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3403491 | 120159 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. [ SOR Code O040A It no. 12.4 Pg no. 140 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 5552.4 | 5552.4 | 2.0 | False | None | None | False | None | False | 11104.8 | 0 | | 3403492 | 120159 | None | code02 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 0.00Mtr To 50.00Mtr] [ SOR Code O010A, It no. 1.1 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 388.5 | 388.5 | 100.0 | False | None | None | False | None | False | 38850.0 | 0 | | 3403493 | 120159 | None | code03 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 50.00Mtr To 100.00Mtr] [ SOR Code O010B, It no.12. 1.2 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 464.1 | 464.1 | 100.0 | False | None | None | False | None | False | 46410.0 | 0 | | 3403494 | 120159 | None | code04 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 100.00Mtr To 150.00Mtr] [ SOR Code O010B, It no. 12.1.3 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 517.65 | 517.65 | 100.0 | False | None | None | False | None | False | 51765.0 | 0 | | 3403495 | 120159 | None | code05 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make arrangements for procuring water for testing) etc. complete For. PVC pipes 200mm dia., 6 kg/sqcm & class 3 m 1115 [ It no.10.1.10Pg no.113 Water supply and UGD works CSR 2023-24 Vol-5] | m | 1170.75 | 1170.75 | 12.0 | False | None | None | False | None | False | 14049.0 | 0 | | 3403496 | 120159 | None | code06 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge Each 164 [ It no.12.34Pg no.143 Water supply and UGD works CSR 2023-24 Vol-5] | No | 172.2 | 172.2 | 2.0 | False | None | None | False | None | False | 344.4 | 0 | | 3403497 | 120159 | None | code07 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;b 3 Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments, and instructions of engineer incharge of work complete.7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" Each 40810[ It no. 13.15.7 Pg no.152 Water supply and UGD works CSR 2023-24 Vol-5] | No | 42850.5 | 42850.5 | 2.0 | False | None | None | False | None | False | 85701.0 | 0 | | 3403498 | 120159 | None | code08 | SUBMERSIBLE CABLE : Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area 1x3x4 Sqm as per IS 694-1990 with ISI Mark and as per its latest amendments.[ It no.13.22.3 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5 | m | 141.75 | 141.75 | 240.0 | False | None | None | False | None | False | 34020.0 | 0 | | 3403499 | 120159 | None | code09 | PRESSURE GAUGE: Supply and delivery at site of brand new best make pressure gauge Size 63 mm bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. [ It no. 13.23.1 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5] | No | 436.8 | 436.8 | 2.0 | False | None | None | False | None | False | 873.6 | 0 | | 3403500 | 120159 | None | code10 | NON RETURN VALVE :Supply and delivery at site of brand new best make non-return valve 50.00mm as per IS 778/1984 with ISI Mark and as per its latest amendments. [ It no. 13.25.1 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5] | No | 1312.5 | 1312.5 | 2.0 | False | None | None | False | None | False | 2625.0 | 0 | | 3403501 | 120159 | None | code11 | POWER CAPACITOR : Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. [ It no.13.25 Pg no.153 Water supply and UGD works CSR 2023-24 Vol-5] | No | 577.5 | 577.5 | 2.0 | False | None | None | False | None | False | 1155.0 | 0 | | 3403502 | 120159 | None | code12 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.[It no.13.26 Pg no.153Water supply and UGD works CSR 2023-24 Vol-5] | No | 1207.5 | 1207.5 | 2.0 | False | None | None | False | None | False | 2415.0 | 0 | | 3403503 | 120159 | None | code13 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments (It no.13.28 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] | m | 577.5 | 577.5 | 240.0 | False | None | None | False | None | False | 138600.0 | 0 | | 3403504 | 120159 | None | code14 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 6 to 15 HP pumps Each 15900 [ It no.13.23.3 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] | No | 16695.0 | 16695.0 | 2.0 | False | None | None | False | None | False | 33390.0 | 0 | | 3403505 | 120159 | None | code15 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no OUTDOOR type NOTE:1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.[ It no.13.24.3 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] 6 to 15 HP pumps Each 17500 | No | 18375.0 | 18375.0 | 2.0 | False | None | None | False | None | False | 36750.0 | 0 | | 3403506 | 120159 | None | code16 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. [ It no.13.33 Pg no.155 Water supply and UGD works CSR 2023-24 Vol-5] | No | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | | 3403507 | 120159 | None | code17 | Labour charges for erection of outdoor type panel board and meter boardunits with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineerincharge of work.Job 1450. [ It no.13.34 Pg no.155 Water supply and UGD works CSR 2023-24 Vol-5] | No | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | | 3403508 | 120159 | None | code18 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. [ It no.13.36 Pg no.156 Water supply and UGD works CSR 2023-24 Vol-5] | No | 141.75 | 141.75 | 2.0 | False | None | None | False | None | False | 283.5 | 0 | | 3403509 | 120159 | None | code19 | EARTHLING : Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia [ It no.13.39 Pg no.156Water supply and UGD works CSR 2023-24 Vol-5] | No | 3937.5 | 3937.5 | 2.0 | False | None | None | False | None | False | 7875.0 | 0 |
| | 1719575878000 | 0 | None | None | Water supply/sewage lines | Providing and installing of 3phase motor pump set in wno.06,07,and in wno.20 under tmc ugarkhurd limit. | 787414.95 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3403510 | 120160 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. [ SOR Code O040A It no. 12.4 Pg no. 140 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 5552.4 | 5552.4 | 3.0 | False | None | None | False | None | False | 16657.2 | 0 | | 3403511 | 120160 | None | code02 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 0.00Mtr To 50.00Mtr] [ SOR Code O010A, It no. 1.1 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 388.5 | 388.5 | 150.0 | False | None | None | False | None | False | 58275.0 | 0 | | 3403512 | 120160 | None | code03 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 50.00Mtr To 100.00Mtr] [ SOR Code O010B, It no.12. 1.2 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 464.1 | 464.1 | 150.0 | False | None | None | False | None | False | 69615.0 | 0 | | 3403513 | 120160 | None | code04 | Sinking of borewell of 165mm dia clear using superfast hydraulic rig of capacity 300 PSIG & above 1100 CFM & above in all strata including over burden utp 20 mtr. Fixing of casing pipes, collars and cap with necessary cutting,threading & welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes collars and caps etc) [ 100.00Mtr To 150.00Mtr] [ SOR Code O010B, It no. 12.1.3 Pg no. 151 Water supply and UGD works CSR 2023-24 Vol-5] | m | 517.65 | 517.65 | 150.0 | False | None | None | False | None | False | 77647.5 | 0 | | 3403514 | 120160 | None | code05 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make arrangements for procuring water for testing) etc. complete For. PVC pipes 200mm dia., 6 kg/sqcm & class 3 m 1115 [ It no.10.1.10Pg no.113 Water supply and UGD works CSR 2023-24 Vol-5] | m | 1170.75 | 1170.75 | 18.0 | False | None | None | False | None | False | 21073.5 | 0 | | 3403515 | 120160 | None | code06 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge Each 164 [ It no.12.34Pg no.143 Water supply and UGD works CSR 2023-24 Vol-5] | No | 172.2 | 172.2 | 3.0 | False | None | None | False | None | False | 516.6 | 0 | | 3403516 | 120160 | None | code07 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;b 3 Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments, and instructions of engineer incharge of work complete.7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" Each 40810[ It no. 13.15.7 Pg no.152 Water supply and UGD works CSR 2023-24 Vol-5] | No | 42850.5 | 42850.5 | 3.0 | False | None | None | False | None | False | 128551.5 | 0 | | 3403517 | 120160 | None | code08 | SUBMERSIBLE CABLE : Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area 1x3x4 Sqm as per IS 694-1990 with ISI Mark and as per its latest amendments.[ It no.13.22.3 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5 | m | 141.75 | 141.75 | 396.0 | False | None | None | False | None | False | 56133.0 | 0 | | 3403518 | 120160 | None | code09 | PRESSURE GAUGE: Supply and delivery at site of brand new best make pressure gauge Size 63 mm bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. [ It no. 13.23.1 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5] | m | 436.8 | 436.8 | 3.0 | False | None | None | False | None | False | 1310.4 | 0 | | 3403519 | 120160 | None | code10 | NON RETURN VALVE :Supply and delivery at site of brand new best make non-return valve 50.00mm as per IS 778/1984 with ISI Mark and as per its latest amendments. [ It no. 13.25.1 Pg no.154 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 1312.5 | 1312.5 | 3.0 | False | None | None | False | None | False | 3937.5 | 0 | | 3403520 | 120160 | None | code11 | POWER CAPACITOR : Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. [ It no.13.25 Pg no.153 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 577.5 | 577.5 | 3.0 | False | None | None | False | None | False | 1732.5 | 0 | | 3403521 | 120160 | None | code12 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.[It no.13.26 Pg no.153Water supply and UGD works CSR 2023-24 Vol-5] | Each | 1207.5 | 1207.5 | 3.0 | False | None | None | False | None | False | 3622.5 | 0 | | 3403522 | 120160 | None | code13 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments (It no.13.28 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] | No | 577.5 | 577.5 | 360.0 | False | None | None | False | None | False | 207900.0 | 0 | | 3403523 | 120160 | None | code14 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 6 to 15 HP pumps Each 15900 [ It no.13.23.3 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] | m | 16695.0 | 16695.0 | 3.0 | False | None | None | False | None | False | 50085.0 | 0 | | 3403524 | 120160 | None | code15 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no OUTDOOR type NOTE:1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.[ It no.13.24.3 Pg no.155Water supply and UGD works CSR 2023-24 Vol-5] 6 to 15 HP pumps Each 17500 | No | 18375.0 | 18375.0 | 3.0 | False | None | None | False | None | False | 55125.0 | 0 | | 3403525 | 120160 | None | code16 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. [ It no.13.33 Pg no.155 Water supply and UGD works CSR 2023-24 Vol-5] | No | 1417.5 | 1417.5 | 3.0 | False | None | None | False | None | False | 4252.5 | 0 | | 3403526 | 120160 | None | code17 | Labour charges for erection of outdoor type panel board and meter boardunits with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineerincharge of work.Job 1450. [ It no.13.34 Pg no.155 Water supply and UGD works CSR 2023-24 Vol-5] | No | 1522.5 | 1522.5 | 3.0 | False | None | None | False | None | False | 4567.5 | 0 | | 3403527 | 120160 | None | code18 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. [ It no.13.36 Pg no.156 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 141.75 | 141.75 | 3.0 | False | None | None | False | None | False | 425.25 | 0 | | 3403528 | 120160 | None | code19 | EARTHLING : Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia [ It no.13.39 Pg no.156Water supply and UGD works CSR 2023-24 Vol-5] | No | 3937.5 | 3937.5 | 3.0 | False | None | None | False | None | False | 11812.5 | 0 | | 3403529 | 120160 | None | code20 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark [ It no.13.30 Pg no.155 Water supply and UGD works CSR 2023-24 Vol-5] | No | 4725.0 | 4725.0 | 3.0 | False | None | None | False | None | False | 14175.0 | 0 |
| | 1719575878000 | 0 | None | None | Water supply/sewage lines | Construction of jalakumbha katti invarious ward in ugarkh limit. | 494932.8 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3403530 | 120161 | None | code01 | Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m [it no.1.17.1 Pg no10 CSR 2023-24 Vol-1]. | Cum | 275.1 | 275.1 | 16.2 | False | None | None | False | None | False | 4456.62 | 0 | | 3403531 | 120161 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other purtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates [it no.2.1.4 Pg no.15 CSR 2023-24 Vol-1]. | Cum | 6527.85 | 6527.85 | 4.05 | False | None | None | False | None | False | 26437.7925 | 0 | | 3403532 | 120161 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6[it no.5.1.1 Pg no.9 Water supply and UGD works CSR 2023-24 Vol-5]. | Cum | 5891.55 | 5891.55 | 16.2 | False | None | None | False | None | False | 95443.11 | 0 | | 3403533 | 120161 | None | code04 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm [It no10.6 Pg no.116 Watersupply UGD works CSR 2023-24 Vol-5]. | Each | 17221.05 | 17221.05 | 12.0 | False | None | None | False | None | False | 206652.6 | 0 | | 3403534 | 120161 | None | code05 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. [ It no.10.7 Pg no.116 Water supply and UGD works CSR 2023-24 Vol-5]. | Each | 1976.1 | 1976.1 | 12.0 | False | None | None | False | None | False | 23713.2 | 0 | | 3403535 | 120161 | None | code06 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for 20 mm Dia [It no.11.7.2 Pg no.129 Water supply and UGD works CSR2023-24 Vol-5]. | Each | 103.95 | 103.95 | 12.0 | False | None | None | False | None | False | 1247.4 | 0 | | 3403536 | 120161 | None | code07 | Providing wrought mild steel (galvanized) 20.00 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. 20mm Dia [It no.11.6.2 Pg no.129 Water supply and UGD works CSR 2023-24Vol-5]. | Each | 103.95 | 103.95 | 12.0 | False | None | None | False | None | False | 1247.4 | 0 | | 3403537 | 120161 | None | code08 | Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any.20mm Dia [It no.11.9.2 Pg no.130 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 112.35 | 112.35 | 12.0 | False | None | None | False | None | False | 1348.2 | 0 | | 3403538 | 120161 | None | code09 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 20mm dia [It no11.1.2 Pg no.125 Water supply and UGD works CSR2023-24 Vol-5] | m | 236.25 | 236.25 | 18.0 | False | None | None | False | None | False | 4252.5 | 0 | | 3403539 | 120161 | None | code10 | 20 mm dia GM (Copper alloy) Gate valves [sl no.11.15.2 Pg no.133 Water supply and UGD works CSR 2023-24 Vol-5] | Each | 932.4 | 932.4 | 12.0 | False | None | None | False | None | False | 11188.8 | 0 | | 3403540 | 120161 | None | code11 | 20 mm dia GM gland cocks [sl no.11.19.2 Pg no.134 Water supply and UGD works CSR 2023-24Vol-5] | Each | 439.95 | 439.95 | 48.0 | False | None | None | False | None | False | 21117.6 | 0 | | 3403541 | 120161 | None | code12 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:10.1.2 PVC pipes 32mm dia., 10 kg/sqcm & class 5 m 67 [It no10.1.2 Pg no.113 Water supply and UGD works CSR 2023-24Vol-5] | m | 70.35 | 70.35 | 120.0 | False | None | None | False | None | False | 8442.0 | 0 | | 3403542 | 120161 | None | code13 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
[it no.8.3.2 Pg no.41PWD CSR 2023-24 Vol-2 ] | Sqm | 349.65 | 349.65 | 50.4 | False | None | None | False | None | False | 17622.36 | 0 | | 3403543 | 120161 | None | code14 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [it no.8.30 Pg no.46 CSR 2023-24 Vol-2 ] | Sqm | 182.7 | 182.7 | 163.5 | False | None | None | False | None | False | 29871.45 | 0 | | 3403544 | 120161 | None | code15 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, sage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2.4.1 Mix 1.2.4 (M15) Using 20 mm nominal size graded crushed coarse aggregates m 6404.00 [it no.2.4.1 no.16 CSR 2023-24 Vol-1]. | Cum | 6724.2 | 6724.2 | 6.23 | False | None | None | False | None | False | 41891.766 | 0 |
|
|
|---|