createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719293172224
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee610.00
emd57200.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 16:30:00
tenderQueryClose12-07-2024 16:00:00
technicalBidOpen19-07-2024 17:00:00
publishedDate29-06-2024 10:39:14
publishedByPostAPMC_SEC_SMG
publishedByUserKPE12909 - MANJUNATHA B
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSECREATRY
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08182250323
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719293172227
version14
createdDateNone
modifiedDateNone
tenderNumberAPMC/2023-24/OW/WORK_INDENT87/CALL-2
titleConstruction of balance road and other works at sub-Market yard, APMC,Holalur under 2022-23 action plan
descriptionConstruction of balance road and other works at sub-Market yard, APMC Holalur under 2022-23 action plan
categoryWORKS
categoryTextWorks
ecv2420187.42
deptNameAgriculture Produce Marketing Committee
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5573
locationNameSECRETARY APMC Office SHIMOGA
provisionalAmount2600000.0
groupOverheadTotalNone
fileNumberAS-03
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17192931720000NoneNoneOther WorksConstruction of balance road and other works at sub-Market yard, APMC,Holalur under 2022-23 action plan2420187.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3341101117372Noneas0001Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in all radius and all lift including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum65.065.0112.35FalseNoneNoneFalseNoneFalse7302.750
3341102117372Noneas0002Earth work excavation by Mechanicle means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in all radius and all liftm including cost of labour, tools & other appurtenaces required to complete the work. . with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum73.073.094.28FalseNoneNoneFalseNoneFalse6882.440
3341103117372Noneas0003Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in all radius and all lift including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils.with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum186.0186.0105.75FalseNoneNoneFalseNoneFalse19669.50
3341104117372Noneas0004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately.Mix 1:4:8 (M5) Using 40 mm and down size graded crushed coarse aggregates with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum5206.05206.040.88FalseNoneNoneFalseNoneFalse212821.280
3341105117372Noneas0005Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregateswith all lead and lifts and work to be carried out as per the instruction of Engineer in charge. FOR DRAINSCum8056.88056.829.7FalseNoneNoneFalseNoneFalse239286.960
3341106117372Noneas0006Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregateswith all lead and lifts and work to be carried out as per the instruction of Engineer in charge FOR CD WORKS.Cum6445.446445.4451.285FalseNoneNoneFalseNoneFalse330554.39040
3341107117372Noneas0007Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapwith all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each2156.02156.04.0FalseNoneNoneFalseNoneFalse8624.00
3341108117372Noneas0008Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Rmtr316.0316.080.0FalseNoneNoneFalseNoneFalse25280.00
3341109117372Noneas0009Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the workRmtr393.0393.080.0FalseNoneNoneFalseNoneFalse31440.00
3341110117372Noneas0010Providing and fixing C.P. brass bib cock of approved quality with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each432.0432.08.0FalseNoneNoneFalseNoneFalse3456.00
3341111117372Noneas0011Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ((plus or less 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (plus or less 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 48x40 mm PVC Extruded section with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Rmtr187.0187.011.4FalseNoneNoneFalseNoneFalse2131.80
3341112117372Noneas0012Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Sqm3803.03803.03.15FalseNoneNoneFalseNoneFalse11979.450
3341113117372Noneas0013Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. . with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Sqm400.0400.0126.0FalseNoneNoneFalseNoneFalse50400.00
3341114117372Noneas0014Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Kg92.092.04933.37FalseNoneNoneFalseNoneFalse453870.040
3341115117372Noneas0015Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum87.087.037.45FalseNoneNoneFalseNoneFalse3258.150
3341116117372Noneas0016Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum413.0413.0112.35FalseNoneNoneFalseNoneFalse46400.550
3341117117372Noneas0017Granular Sub-Base: Plant Mix Method: Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II Material with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum2397.02397.056.18FalseNoneNoneFalseNoneFalse134663.460
3341118117372Noneas0018Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. Dry Lean Cement Concrete Sub- base with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum4025.04025.037.45FalseNoneNoneFalseNoneFalse150736.250
3341119117372Noneas0019Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Cum6512.06512.074.9FalseNoneNoneFalseNoneFalse487748.80
3341120117372Noneas0020Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Kg120.0120.0270.0FalseNoneNoneFalseNoneFalse32400.00
3341121117372Noneas0021Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI and any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned - LED Streetlight 40W with all lead, lifts, loading and unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the workEach740.0740.06.0FalseNoneNoneFalseNoneFalse4440.00
3341122117372Noneas0022Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each2399.02399.03.0FalseNoneNoneFalseNoneFalse7197.00
3341123117372Noneas0023Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Sqm106.0106.061.6FalseNoneNoneFalseNoneFalse6529.60
3341124117372Noneas0024Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Sqm1104.01104.01.0FalseNoneNoneFalseNoneFalse1104.00
3341125117372Noneas0025Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A SP with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each726.0726.02.0FalseNoneNoneFalseNoneFalse1452.00
3341126117372Noneas0026Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility . with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each4054.04054.01.0FalseNoneNoneFalseNoneFalse4054.00
3341127117372Noneas0027Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers - 63 A.with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each372.0372.02.0FalseNoneNoneFalseNoneFalse744.00
3341128117372Noneas0028Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thickwith all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Rmtr80.080.0300.0FalseNoneNoneFalseNoneFalse24000.00
3341129117372Noneas0029Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each3750.03750.02.0FalseNoneNoneFalseNoneFalse7500.00
3341130117372Noneas0030Supplying and fixing PVC/metal conduit Deep junction box - 25 mm deep Junction box all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each51.051.045.0FalseNoneNoneFalseNoneFalse2295.00
3341131117372Noneas0031Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each276.0276.040.0FalseNoneNoneFalseNoneFalse11040.00
3341132117372Noneas0032Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each386.0386.030.0FalseNoneNoneFalseNoneFalse11580.00
3341133117372Noneas0033Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 1 mm2with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the workRmtr18.018.0250.0FalseNoneNoneFalseNoneFalse4500.00
3341134117372Noneas0034Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 2.5 mm2with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Rmtr40.040.0400.0FalseNoneNoneFalseNoneFalse16000.00
3341135117372Noneas0035Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 4.00 mm2with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Rmtr59.059.0400.0FalseNoneNoneFalseNoneFalse23600.00
3341136117372Noneas0036Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 4-5 Way with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each138.0138.010.0FalseNoneNoneFalseNoneFalse1380.00
3341137117372Noneas0037Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 8 Way with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each250.0250.012.0FalseNoneNoneFalseNoneFalse3000.00
3341138117372Noneas0038Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 4 Module. with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each175.0175.012.0FalseNoneNoneFalseNoneFalse2100.00
3341139117372Noneas0039Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 8 Module with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each302.0302.012.0FalseNoneNoneFalseNoneFalse3624.00
3341140117372Noneas0040Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293- 6A One Way Switch with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each88.088.080.0FalseNoneNoneFalseNoneFalse7040.00
3341141117372Noneas0041Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293- DP Switch with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each375.0375.06.0FalseNoneNoneFalseNoneFalse2250.00
3341142117372Noneas0042Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16A Universal Socketwith all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each249.0249.040.0FalseNoneNoneFalseNoneFalse9960.00
3341143117372Noneas0043Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50/60Hz and Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each496.0496.06.0FalseNoneNoneFalseNoneFalse2976.00
3341144117372Noneas0044Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.with all lead and lifts and work to be carried out as per the instruction of Engineer in charge.Each486.0486.06.0FalseNoneNoneFalseNoneFalse2916.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17192932160000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17192932160000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17192932160000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17192932160000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17192932160000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17193713360000NoneNoneELIGIBILITYGST 18% ADDED SEPARATELYNone
17193713960000NoneNoneELIGIBILITYALL TERMS AND CONDITIONS AS PER TENDER DOCUMENT/NOTIFICATIONNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneUpload all documents as per tender document/notificationCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RELEVANT DOCUMENT
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
UPLOAD ALL TECHNICAL DOCUMENTS AS PER TENDER DOCUMENT/NOTIFICATIONTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone