createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719591741326
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd6625.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose16-07-2024 17:30:00
tenderQueryClose16-07-2024 16:00:00
technicalBidOpenNone
publishedDate28-06-2024 22:07:14
publishedByPostTMC_CO_HDK
publishedByUserKPE14295 - SURESHA P
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonJUNIOR ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8217657598
tenderSupplierListNone
tenderSchedule
createdTs1719591741358
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT19917
titleConstruction of Physical handicapped toilet at ward no 15 Govt PU College Junior College in HD Kote TMC Limit
descriptionConstruction of Physical handicapped toilet at ward no 15 Govt PU College Junior College in HD Kote TMC Limit
categoryWORKS
categoryTextWorks
ecv265000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2447
locationNameDMA Town Municipal Council H D Kote
provisionalAmount265000.0
groupOverheadTotal42323.96
fileNumberSFCCCS/2024-25/HDK/115
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17195917410000NoneNoneOther WorksConstruction of Physical handicapped toilet at ward no 15 Govt PU College Junior College in HD Kote TMC Limit222676.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3405262120229Nonecode01Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. CSR-2023-24 .I.No.1.1, PN-5 of Volume1.Sqm93.7393.736.72FalseNoneNoneFalseNoneFalse629.86560
3405263120229Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CSR 2023-24 Sl. No.1.14.1, Page No.8 Volume1.Cum105.06105.066.075FalseNoneNoneFalseNoneFalse638.23950
3405264120229Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates. CSR 2023-24 Sl. No.2.1.1, P-15 V-1Cum5498.145498.142.4029FalseNoneNoneFalseNoneFalse13211.4806060
3405265120229Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). CSR 2023-24 Sl. No.5.4, Page No.9Volume2.Cum6580.676580.673.88FalseNoneNoneFalseNoneFalse25532.99960
3405266120229Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. CSR 2023-24 I No.2.5.2, PNO-17 V-1Cum7048.297048.290.12FalseNoneNoneFalseNoneFalse845.79480
3405267120229Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. CSR 2023-24 Si No.2.5.2, Page No.16 V-1Cum7048.297048.290.2553FalseNoneNoneFalseNoneFalse1799.4284370
3405268120229Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. CSR 2023-24 Sl. No.1.10, Page No.7 Volume1.Cum164.8164.813.944FalseNoneNoneFalseNoneFalse2297.97120
3405269120229Nonecode08Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. CSR-2023-24 Addendum -1 PN-111 volume-1 2023-24Cum4228.974228.970.2553FalseNoneNoneFalseNoneFalse1079.6560410
3405270120229Nonecode09Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). CSR 2023-24 Si No.11.32, Page No.84Volume2.Tonne92140.7192140.710.0096FalseNoneNoneFalseNoneFalse884.5508160
3405271120229Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. CSR 2023-24 I NO 6.32 P 17 V -2Cum1349.31349.35.271FalseNoneNoneFalseNoneFalse7112.16030
3405272120229Nonecode11Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 Sl. No.8.1.1. Page No.41 Volume2.Sqm262.65262.6518.87FalseNoneNoneFalseNoneFalse4956.20550
3405273120229Nonecode12Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 Sl. No.8.5.1, Page No.42 Volume2.Sqm376.98376.9827.3FalseNoneNoneFalseNoneFalse10291.5540
3405274120229Nonecode13Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 Sl. No.8.9, Page No.42 Volume2.Sqm396.55396.5517.475FalseNoneNoneFalseNoneFalse6929.711250
3405275120229Nonecode14Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.CSR2023-24 I NO 9.9 Page No.60, V-2Sqm1108.281108.286.72FalseNoneNoneFalseNoneFalse7447.64160
3405276120229Nonecode15Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete CSR 2023-24 Vol -2, I No - 10.14 , P No - 71,Sqm1139.181139.184.455FalseNoneNoneFalseNoneFalse5075.04690
3405277120229Nonecode16Providing and fixing Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer ,including welding and bolted with special shaped washers etc.complete. Hot finished welded type tubes including cost of materials, labour , usage charges of machinery complete as per specifications and as per directions oft he Engineer-in-Charge.CSR 2023-24 si no 11.16.1 pg 89 vol 2Kg112.27112.27144.0FalseNoneNoneFalseNoneFalse16166.880
3405278120229Nonecode17Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation asapproved byEngineer-in-charge)0.50mm(+0.05%)total coated thickness with zinc coating 120gram sperm 2 asper IS:277,in240m pa steel grade,5-7microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12m or as desired by Engineer-in-charge. The sheet shall be fixed usingself drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cuttingtosize andshape whereverrequired..CSR 2023-24 si no 7.38 pg 26 vol 2Sqm572.68572.689.75FalseNoneNoneFalseNoneFalse5583.630
3405279120229Nonecode18Fixing doors, window and ventilators in walls. (CSR 2023-24 Vol -2, I No - 20.99 , P No - 183,m359.47359.470.75FalseNoneNoneFalseNoneFalse269.60250
3405280120229Nonecode19Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam ( Vol -2, CSR 2023-24 I No -12.55.1 , P No -104,Sqm2436.982436.981.89FalseNoneNoneFalseNoneFalse4605.89220
3405281120229Nonecode20Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..CSR 2023-24 Vol -2, I No - 11.5.1 , P No - 77,Sqm4612.344612.342.1FalseNoneNoneFalseNoneFalse9685.9140
3405282120229Nonecode21Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 I No.8.30, Page No.46 Volume2.Sqm179.22179.2226.025FalseNoneNoneFalseNoneFalse4664.20050
3405283120229Nonecode22Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.2.1, VOL-6, 19/20 mm dia 2 mm thick,Mtr67.9867.9815.0FalseNoneNoneFalseNoneFalse1019.70
3405284120229Nonecode23Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, IN-CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.2.2, PN-2, VOL-6, 25 mm dia 2 mm thick,Mtr80.3480.3415.0FalseNoneNoneFalseNoneFalse1205.10
3405285120229Nonecode24Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.3.1, PN-2, VOL-6, 19/20 mm dia 2 mm thickMtr70.0470.042.0FalseNoneNoneFalseNoneFalse140.080
3405286120229Nonecode25Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.3.2, PN-2, 25 mm dia 2 mm thickMtr81.3781.374.0FalseNoneNoneFalseNoneFalse325.480
3405287120229Nonecode26Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.1.1, PN-5, Vol-6, Short point upto 3m from tapping point to out let via switch box.Point293.55293.551.0FalseNoneNoneFalseNoneFalse293.550
3405288120229Nonecode27Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, in-2.1.2, pn-5, vol-6, Medium point above 3m upto 6m from tapping point to out let via switch box.Point405.82405.823.0FalseNoneNoneFalseNoneFalse1217.460
3405289120229Nonecode28Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.1.3, PN-5, VOL-6, Long point above 6m upto 10m from tapping point to out let via switch boxPoint587.1587.11.0FalseNoneNoneFalseNoneFalse587.10
3405290120229Nonecode29Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.2, PN-5, 1.5 mm2Mtr26.7826.7820.0FalseNoneNoneFalseNoneFalse535.60
3405291120229Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.3, PN-5, VOL-6, 2.5 mm2Mtr43.2643.2615.0FalseNoneNoneFalseNoneFalse648.90
3405292120229Nonecode31Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.4, PN-5, VOL-6, 4 mm2Mtr64.8964.8910.0FalseNoneNoneFalseNoneFalse648.90
3405293120229Nonecode32Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654,CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.1.2, PN-8, VOL-6, 6A 3/5 WayEach151.41151.411.0FalseNoneNoneFalseNoneFalse151.410
3405294120229Nonecode33Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.6.9, PN-9, VOL-6, 32A DP SwitchEach335.78335.781.0FalseNoneNoneFalseNoneFalse335.780
3405295120229Nonecode34Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.4.2, PN-8, VOL-6, 1-3 Way.Each127.72127.721.0FalseNoneNoneFalseNoneFalse127.720
3405296120229Nonecode35Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.4.6, PN-8, VOL-6, 10-12 Way.Each268.83268.831.0FalseNoneNoneFalseNoneFalse268.830
3405297120229Nonecode36Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.5.2, PN-8, VOL-6, 3 ModuleEach165.83165.831.0FalseNoneNoneFalseNoneFalse165.830
3405298120229Nonecode37Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.5.6, PN-8, VOL-6, 10-12 ModuleEach354.32354.321.0FalseNoneNoneFalseNoneFalse354.320
3405299120229Nonecode38Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greaterthan 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED fficiencygreaterthan1301m/w, nominal CRI greaterthan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.Note : 3) LED street lights that is procured, shall comply to the specification as per DMA Order(No. 25775DMA 69 DEVT 2018-19 Dated : 03-01-2019 ).(PWD Electrical CSR 2021-2022, IN-3.5.6, PN-5(Part-1)), LED Streetlight 25 WEach2497.752497.751.0FalseNoneNoneFalseNoneFalse2497.750
3405300120229Nonecode39Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 24, IN-13.2.1, PN-56, VOL-6, Using 25mm dia G.I.PipeEach1239.091239.091.0FalseNoneNoneFalseNoneFalse1239.090
3405301120229Nonecode40Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.5, PN-56, VOL-6.Each166.86166.861.0FalseNoneNoneFalseNoneFalse166.860
3405302120229Nonecode41Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V@ 50/60Hz & Power factor greaterthan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-11.3.2, PN-43, VOL-6, LED light fighting LED light fitting 1 x 4' - 20/22 WEach710.7710.71.0FalseNoneNoneFalseNoneFalse710.70
3405303120229Nonecode42Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreaterthan 70%. efficacy greaterthan80 lumen per W, lifegreaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greaterthan 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.,CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-11.11.4, PN-47, VOL-6, 9W, 6500KEach158.62158.621.0FalseNoneNoneFalseNoneFalse158.620
3405304120229Nonecode43Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.7.1, PN-56, VOL-6.Each125.66125.662.0FalseNoneNoneFalseNoneFalse251.320
3405305120229Nonecode44Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.14.6, PN-10, VOL-6, 6A Lamp HolderEach73.1373.132.0FalseNoneNoneFalseNoneFalse146.260
3405306120229Nonecode45Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-6.1, PN-30, VOL-6.Each1536.761536.763.0FalseNoneNoneFalseNoneFalse4610.280
3405307120229Nonecode46Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.13, PN- 57, VOL-6Each728.21728.213.0FalseNoneNoneFalseNoneFalse2184.630
3405308120229Nonecode47Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.18.4, PN-17, VOL-6, 6-32 A DPEach761.17761.171.0FalseNoneNoneFalseNoneFalse761.170
3405309120229Nonecode48Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.42.1, PN-20, VOL-6, 14SWG.Sq CM0.510.511000.0FalseNoneNoneFalseNoneFalse510.00
3405310120229Nonecode49Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.40.1, PN-20, VOL-6, 100 A 4 x 30 x 6 mm Aluminium StripsMtr2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
3405311120229Nonecode50Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.30, PN-19, VOL-6Each1421.41421.41.0FalseNoneNoneFalseNoneFalse1421.40
3405312120229Nonecode51Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-12.56, PN-54, VOL-6.No3615.33615.31.0FalseNoneNoneFalseNoneFalse3615.30
3405313120229Nonecode52Guy Wire & GI Wire as per IS-2141, GI Wire 8 SWG, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-8.02, PN-55, VOL-6Mtr77291.277291.20.025FalseNoneNoneFalseNoneFalse1932.280
3405314120229Nonecode53Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m, PWD CSR 2023-2024, IN 1.6.1, PN-6, VOL-1Cum498.52498.529.0FalseNoneNoneFalseNoneFalse4486.680
3405315120229Nonecode541.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 24, IN-32.05, PN-13, VOL-6, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km146097.26146097.260.06FalseNoneNoneFalseNoneFalse8765.83560
3405316120229Nonecode55Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-21.05, PN-52, VOL-6.Km21512.5821512.580.06FalseNoneNoneFalseNoneFalse1290.75480
3405317120229Nonecode56Aluminium End Terminal (Lug), CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-60.02, PN-27, VOL-6. 16SqmmEach3.093.092.0FalseNoneNoneFalseNoneFalse6.180
3405318120229Nonecode57Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. CSR for Water Supply & Sewerage Works 2023 - 24, IN-11.2.5, PN-127, VOL-5, .Medium Duty GI pipe of 40mm diaMtr502.64502.642.0FalseNoneNoneFalseNoneFalse1005.280
3405319120229Nonecode58Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-35.01, PN-15, VOL-6, up to 4C x 50 Sqmm,Set333.72333.721.0FalseNoneNoneFalseNoneFalse333.720
3405320120229Nonecode59Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete, CSR for Water Supply & Sewerage Works 2023 - 24, IN-13.4.2, PN-149, VOL-5, 0.50 HP/0.37kW - 7 STG(stage)Each11180.6511180.651.0FalseNoneNoneFalseNoneFalse11180.650
3405321120229Nonecode60Providing and fixing white vitreous china clay, water closet orissa patterrn of size 580x440mm with integral type footrests, 100mm S or P trap,10litre low level white P.V.C flushing cistern, including flush pipe with manually controlled device (handle lever) conforming to IS:7231,with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.No5030.525030.521.0FalseNoneNoneFalseNoneFalse5030.520
3405322120229Nonecode61Providing and fixing wash basin with C.I brackets,15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the wall wherever required: using white vitreous china wash basin size 550x400mm with a 15mm CP Brass single hole basin mixer.No4244.634244.631.0FalseNoneNoneFalseNoneFalse4244.630
3405323120229Nonecode62Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete.No78.2878.281.0FalseNoneNoneFalseNoneFalse78.280
3405324120229Nonecode63Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete.No90.6490.641.0FalseNoneNoneFalseNoneFalse90.640
3405325120229Nonecode64Supply and delivery at site special moulded variety PVC reducer as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendmentsNo268.83268.831.0FalseNoneNoneFalseNoneFalse268.830
3405326120229Nonecode65Supply and delivery at site special moulded variety PVC elbows as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendmentsNo197.76197.761.0FalseNoneNoneFalseNoneFalse197.760
3405327120229Nonecode66Supply and delivery at site special moulded variety PVC elbows as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendmentsNo311.06311.061.0FalseNoneNoneFalseNoneFalse311.060
3405328120229Nonecode67Supply and delivery at site special moulded variety PVC bend as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendmentsNo252.35252.351.0FalseNoneNoneFalseNoneFalse252.350
3405329120229Nonecode68Supply and delivery at site special moulded variety PVC bend as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments.No506.76506.761.0FalseNoneNoneFalseNoneFalse506.760
3405330120229Nonecode69Supply and delivery at site special moulded variety PVC couplers as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendmentsNo69.0169.012.0FalseNoneNoneFalseNoneFalse138.020
3405331120229Nonecode70Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr9.279.271000.0FalseNoneNoneFalseNoneFalse9270.00
3405332120229Nonecode71Providing and fixing chlorinated polyethyl chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one steps cpvc solvent cement and the cost of cutting chases and making good the same including testing of joint complete as per direction of engineer in charge. Concealed work, including cutting chases and making good the walls etcm491.31491.3130.0FalseNoneNoneFalseNoneFalse14739.30
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17195917430000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17195917430000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17195917430000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17195917430000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17195917430000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17195917430000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17195917430000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17195917430000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17195917430000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17195917430000NoneNoneELIGIBILITYBanker DetailsNone
17195917520000NoneNoneELIGIBILITYBIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDNone
17195917580000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-1None
17195917620000NoneNoneELIGIBILITYThe authority reserves right to accept or reject of all tenders without giving any reasonsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual turnover certificate and balance sheetTrueTechnical Bid
Class IV and above KPWD contractor registration certificateTrueTechnical Bid
Similar Work done certificate issued by not below the rank of Executive EngineerTrueTechnical Bid
BIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone