createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719489504773
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd3665.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-07-2024 17:00:00
tenderQueryClose11-07-2024 16:00:00
technicalBidOpen12-07-2024 17:30:00
publishedDate28-06-2024 19:34:33
publishedByPostTP_CO_KBR
publishedByUserKPE17185 - HALASIDDA YALLAPPA SULLANAVAR
bidValidityPeriod180
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonH Y Sulannavar
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08338297097
mobileNumber9986559986
tenderSupplierListNone
tenderSchedule
createdTs1719489504804
version16
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT19700
titleconstruction of cistern at Gangayagol Totta And Meerapurhatti Khotwadi Totta in Kabbur TP Limit 2Drilling Borewell and Installation of Motor pump at Kengeri kodi Near Shri Kalikadevi Math in kabbur tp limit
description1construction of cistern at Gangayagol Totta And Meerapurhatti Khotwadi Totta in Kabbur TP Limit 2Drilling Borewell and Installation of Motor pump at Kengeri kodi Near Shri Kalikadevi Math in kabbur tp limit
categoryWORKS
categoryTextWorks
ecv293132.20
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2509
locationNameDMA Town Panchayat Kabbur
provisionalAmount350000.0
groupOverheadTotalNone
fileNumberSFCDW/2023-24/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194895050000NoneNoneWater supply/sewage lines1 construction of cistern at Gangayagol Totta And Meerapurhatti Khotwadi Totta in Kabbur TP Limit 2Drilling Borewell and Installation of Motor pump at Kengeri kodi Near Shri Kalikadevi Math in kabbur tp limit293132.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3387918119300Nonecode01Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. CSR 2023-24 Volume V (P No: 140 I.No: 12.4)Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3387919119300Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 m CSR 2023-24 Volume V (P No: 139 I.No: 12.1.1)Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3387920119300Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 m CSR 2023-24 Volume V (P No: 139 I.No: 12.1.2)Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3387921119300Nonecode04Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 m CSR 2023-24 Volume V (P No: 139 I.No: 12.1.3)Mtr517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
3387922119300Nonecode05Supply of ISI mark 175mm nominal bore, plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends. threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m. prices include Collar-Medium duty. CSR 2023-24 Volume V (P No: 143 I.No: 12.32)Mtr2029.652029.658.0FalseNoneNoneFalseNoneFalse16237.20
3387923119300Nonecode06Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. CSR 2023-24 Volume V (P No: 143 I.No: 12.33)Each157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3387924119300Nonecode07Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. CSR 2023-24 Volume V (P No: 143 I.No: 12.34)Each172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3387925119300Nonecode08Providing, supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, as per necessary amendments and instructions of engineer in charge of work. TARO ,Texmo, V.Gaurd ,ATALANTA, SUGUNA, CRI, KIRLOSKAR and Other Equivaluent Pumps For 5.00 HP - 135 LPM @ 84 m = 12 STG Outlet Dia - 2.00" CSR 2023-24 Volume V (P No: 151 I.No: 13.13.4Each30278.8530278.851.0FalseNoneNoneFalseNoneFalse30278.850
3387926119300Nonecode09Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 CSR 2023-24 Volume V (P No: 154 I.No: 13.22.2)Mtr89.2589.25155.0FalseNoneNoneFalseNoneFalse13833.750
3387927119300Nonecode10Supplying, laying and jointing HDPE pipes of specified grade andconforming to IS 4984-2016 with latest ammendments and conveyingto work site including loading and unloadingat both destinations androlling and lowering into trenches, laying true to line and jointing ofpipes and specials For Grade PE80 PN 6.0 40 mmdia( MR)with ISI mark with its latest amendments. CSR 2023-24 Volume V (P No: 95 I.No: 9.1)Mtr126.0126.0155.0FalseNoneNoneFalseNoneFalse19530.00
3387928119300Nonecode11Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. CSR 2023-24 Volume V (P No: 155 I.No:13.31)Mtr42.042.0150.0FalseNoneNoneFalseNoneFalse6300.00
3387929119300Nonecode12Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for UPVC Column pipes for Submersible pump sets CSR 2023-24 Volume V (P No: 155 I.No:13.29)Set1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3387930119300Nonecode13Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer in charge of work. CSR 2023-24 Volume V (P No: 156 I.No:13.32)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3387931119300Nonecode14Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments Size 63 mm CSR 2023-24 Volume V (P No: 154 I.No:13.23.1)Each436.8436.81.0FalseNoneNoneFalseNoneFalse436.80
3387932119300Nonecode15Supply and delivery at site of brand new best make gate valve as per IS778/1984 with ISI Mark and as per its latest amendments Size 50 mm CSR 2023-24 Volume V (P No: 154 I.No:13.24.1)Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3387933119300Nonecode16Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm CSR 2023-24 Volume V (P No: 154 I.No:13.25.1)Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3387934119300Nonecode17Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrical Protection Like single Phase preventer, under voltage over Voltage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter for out door 3UP to 6HP pumps CSR 2023-24 Volume V (P No: 154 & 155 I.No:13.23.2)Each10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3387935119300Nonecode18Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. CSR 2023-24 Volume V (P No: 155 I.No:13.25)Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3387936119300Nonecode19Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. CSR 2023-24 Volume V (P No: 155 I.No:13.26)Per 3 Poles1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3387937119300Nonecode20Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. CSR 2023-24 Volume V (P No: 156 I.No:13.24)Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3387938119300Nonecode21Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments, as per specifications with testing of as per instructions of engineer in charge of work 3.5 6 sqmm.CSR 2023 24 Volume V (P No: 156 I.No:13.35.2)Mtr168.0168.015.0FalseNoneNoneFalseNoneFalse2520.00
3387939119300Nonecode22Providing, Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen insulating compound complete with terminals, clamps ,bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer in charge of work. 3.5x6 Sqm CSR 2023-24 Volume V (P No: 156 I.No:13.38.1)Each393.75393.751.0FalseNoneNoneFalseNoneFalse393.750
3387940119300Nonecode23Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia CSR 2023-24 Volume V (P No: 157 I.No:13.39) .Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3387941119300Nonecode24For Electrical charges ( Registering ,Deposite ,bond Meter ,Test report and Bond papersLS15750.015750.01.0FalseNoneNoneFalseNoneFalse15750.00
3387942119300Nonecode01Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m. CSR 2023-24 P.No.5/I No.1.4.1 Vol-1Cum254.1254.11.536FalseNoneNoneFalseNoneFalse390.29760
3387943119300Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M10) Using 40 mm nominal size graded crushed coarse aggregates CSR 2023-24 P.No.15/I No.2.1.3 Vol-1Cum5448.05448.00.768FalseNoneNoneFalseNoneFalse4184.0640
3387944119300Nonecode03Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. .CSR 2023-24 P.No.16/I No.2.3.1 Vol-1 (Including Form work 3%)Cum6838.326838.323.4955FalseNoneNoneFalseNoneFalse23903.347560
3387945119300Nonecode04RCC pipe NP3 1200 mm dia & 2.5 M long .CSR 2023-24 P.No.A-45 /I No.697 Vol-5m6090.06090.05.0FalseNoneNoneFalseNoneFalse30450.00
3387946119300Nonecode05Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. CSR 2023-24 P.No.116/I No. 10.7 Vol-5Each1976.11976.12.0FalseNoneNoneFalseNoneFalse3952.20
3387947119300Nonecode06Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 P.No 41/I No.8.1.2 Vol-2Sqm253.05253.058.399FalseNoneNoneFalseNoneFalse2125.366950
3387948119300Nonecode07Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 P.No.46/I No. 8.30 Vol-2Sqm182.7182.729.0FalseNoneNoneFalseNoneFalse5298.30
3387949119300Nonecode08Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe of 50mm dia. CSR 2023-24 P.No.128 /I No. 11.3.6 Vol-5m731.85731.854.0FalseNoneNoneFalseNoneFalse2927.40
3387950119300Nonecode09Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe of 20mm dia CSR 2023-24 P.No.127 /I No. 11.3.3 Vol-5m376.95376.951.0FalseNoneNoneFalseNoneFalse376.950
3387951119300Nonecode10Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any.For 20 mm dia GI collar. CSR 2023-24 P.No.129 /I No. 11.6.2 Vol-5Each103.95103.952.0FalseNoneNoneFalseNoneFalse207.90
3387952119300Nonecode11Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for:For 50 mm dia GI elbow. CSR 2023-24 P.No.129 /I No. 11.7.6 Vol-5Each280.35280.352.0FalseNoneNoneFalseNoneFalse560.70
3387953119300Nonecode12Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia GI TEE. CSR 2023-24 P.No.130 /I No. 11.9.6 Vol-5Each311.85311.852.0FalseNoneNoneFalseNoneFalse623.70
3387954119300Nonecode13Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 g. CSR 2023-24 P.No.120 /I No. 13.17.1 Vol-2Nos165.9165.92.0FalseNoneNoneFalseNoneFalse331.80
3387955119300Nonecode14Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade. CSR 2023-24 P.No.120 /I No. 13.17.1 Vol-2cm1.681.684000.0FalseNoneNoneFalseNoneFalse6720.00
3387956119300Nonecode15Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. Complete. 63mm dia 6 Kg/m2 CSR 2023-24 P.No.120/I No. 10.14.8 Vol-5m135.73135.7314.0FalseNoneNoneFalseNoneFalse1900.220
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194895080000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194895080000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194895080000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194895080000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194895080000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194896710000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17194896800000NoneNoneELIGIBILITYAccepted Contractor to be Submitted of Tender Deference amount at the time of LOA.None
17194896890001NoneNoneELIGIBILITYQuantity wise similar type of work done certificate to be submittedNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneWork Done CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLine of CreditPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAudited CA Certificate of Annual TurnoverPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAttach scan copy of Pan card and Aadhaar cardPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach scan copy of Pan card and Aadhaar card
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
This Tender is For ST Contractors OnlyTrueTechnical Bid
Enclosed ST Cast certificate from authorizedTrueTechnical Bid
Contractor Registration CertificateTrueTechnical Bid
5year Annual Turnover CertificateTrueTechnical Bid
PAN Card and GST RegistrationTrueTechnical Bid
Any work done cost of 25percentage of Estimate AmountTrueTechnical Bid
Line of credit certificate from Nationalized bankTrueTechnical Bid
Aadhar Card or Address Proof Document For CommunicationTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone