| 3419413 | 121062 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 8.6699 | False | None | None | False | None | False | 928.54629 | 0 |
| 3419414 | 121062 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.578 | False | None | None | False | None | False | 3634.7241 | 0 |
| 3419415 | 121062 | None | code03 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6842.88 | 6842.88 | 2.03 | False | None | None | False | None | False | 13891.0464 | 0 |
| 3419416 | 121062 | None | code04 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11340.0 | 11340.0 | 0.9 | False | None | None | False | None | False | 10206.0 | 0 |
| 3419417 | 121062 | None | code05 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10044.0 | 10044.0 | 0.61 | False | None | None | False | None | False | 6126.84 | 0 |
| 3419418 | 121062 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10692.0 | 10692.0 | 0.61 | False | None | None | False | None | False | 6522.12 | 0 |
| 3419419 | 121062 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Each | 89457.0 | 89457.0 | 0.53 | False | None | None | False | None | False | 47412.21 | 0 |
| 3419420 | 121062 | None | code08 | Providing 20 mm cement plaster of mix 14 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge | Sqm | 371.7 | 371.7 | 17.3699 | False | None | None | False | None | False | 6456.39183 | 0 |
| 3419421 | 121062 | None | code09 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. | Kgs | 142.8 | 142.8 | 222.75 | False | None | None | False | None | False | 31808.7 | 0 |
| 3419422 | 121062 | None | code10 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 16.47 | False | None | None | False | None | False | 1539.1215 | 0 |
| 3419423 | 121062 | None | code11 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 7.425 | False | None | None | False | None | False | 1083.67875 | 0 |
| 3419424 | 121062 | None | code12 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 65mm dia etc. complete. | m | 754.95 | 754.95 | 125.0 | False | None | None | False | None | False | 94368.75 | 0 |
| 3419425 | 121062 | None | code13 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI collar: | Each | 327.6 | 327.6 | 12.0 | False | None | None | False | None | False | 3931.2 | 0 |
| 3419426 | 121062 | None | code14 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming, 1991 with latest amendments if any. For 65 mm dia GI elbow | Each | 311.85 | 311.85 | 4.0 | False | None | None | False | None | False | 1247.4 | 0 |
| 3419427 | 121062 | None | code15 | Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI BEND | Each | 424.2 | 424.2 | 2.0 | False | None | None | False | None | False | 848.4 | 0 |
| 3419428 | 121062 | None | code16 | Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI TEE | Each | 391.65 | 391.65 | 2.0 | False | None | None | False | None | False | 783.3 | 0 |
| 3419429 | 121062 | None | code17 | Supply and delivery at site wrought middle steel (galvanized) GI socket confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI SOCKET | Each | 391.65 | 391.65 | 2.0 | False | None | None | False | None | False | 783.3 | 0 |
| 3419430 | 121062 | None | code18 | Supply and delivery at site wrought middle steel (galvanized) GI Plugs confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI Plugs | Each | 248.85 | 248.85 | 2.0 | False | None | None | False | None | False | 497.7 | 0 |
| 3419431 | 121062 | None | code19 | Supply and delivery at site wrought middle steel (galvanized) GI Union confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI Union | Each | 368.55 | 368.55 | 4.0 | False | None | None | False | None | False | 1474.2 | 0 |
| 3419432 | 121062 | None | code20 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 65 mm dia GM (Copper alloy) Gate valves | Each | 1962.45 | 1962.45 | 2.0 | False | None | None | False | None | False | 3924.9 | 0 |
| 3419433 | 121062 | None | code21 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antigl are clear diffuser with Injection mould edpolycarbonate material, delivering superior lightout put Rated life Burning Hrs 50000hr Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70degrees. CCT 5500K, IP66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 withmains, SurgeProtection Min 5KV along with Over voltage Overload, short circuit miss wiring protection. Compatible for pole mounting withouter dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V50 60Hz application. Compliance to IS10322 IEC60598, LM79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 70W System Power consumption. LED Efficiency 1301m w, nominalCRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL CPRI and any Government certified agency Design Development facility certified by ISO9001 2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Bodypart. Warranty of 2Years against any manufacturing defect working understandard electrical conditions as mentioned above should be given by LEDmanufacturer and Cree Nichia Lumileds Osram make LED Source. LED Streetlight 120W | Each | 10563.0 | 10563.0 | 4.0 | False | None | None | False | None | False | 42252.0 | 0 |
| 3419434 | 121062 | None | code22 | Supplying and Fixing of 32 mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or railor RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. | Cum | 1097.25 | 1097.25 | 4.0 | False | None | None | False | None | False | 4389.0 | 0 |
| 3419435 | 121062 | None | code23 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 | m | 96.6 | 96.6 | 48.0 | False | None | None | False | None | False | 4636.8 | 0 |
| 3419436 | 121062 | None | code24 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 85.05 | 85.05 | 150.0 | False | None | None | False | None | False | 12757.5 | 0 |
| 3419437 | 121062 | None | code25 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 58.8 | 58.8 | 25.0 | False | None | None | False | None | False | 1470.0 | 0 |
| 3419438 | 121062 | None | code26 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 135 x 160 x 65 mm | Each | 225.75 | 225.75 | 10.0 | False | None | None | False | None | False | 2257.5 | 0 |
| 3419439 | 121062 | None | code27 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 365.4 | 365.4 | 2.0 | False | None | None | False | None | False | 730.8 | 0 |
| 3419440 | 121062 | None | code28 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod. | No | 168.0 | 168.0 | 6.0 | False | None | None | False | None | False | 1008.0 | 0 |
| 3419441 | 121062 | None | code29 | Supplying and fixing surface / flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick / C.C wall, including necessary rawl plugs, Machine / NF screws etc., complete. 8 Way | Each | 229.95 | 229.95 | 10.0 | False | None | None | False | None | False | 2299.5 | 0 |
| 3419442 | 121062 | None | code30 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch | Point | 299.25 | 299.25 | 12.0 | False | None | None | False | None | False | 3591.0 | 0 |
| 3419443 | 121062 | None | code31 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch | Point | 413.7 | 413.7 | 12.0 | False | None | None | False | None | False | 4964.4 | 0 |
| 3419444 | 121062 | None | code32 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch | Point | 598.5 | 598.5 | 12.0 | False | None | None | False | None | False | 7182.0 | 0 |
| 3419445 | 121062 | None | code33 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2 | Mtr | 75.6 | 75.6 | 200.0 | False | None | None | False | None | False | 15120.0 | 0 |
| 3419446 | 121062 | None | code34 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2 | Mtr | 98.7 | 98.7 | 100.0 | False | None | None | False | None | False | 9870.0 | 0 |
| 3419447 | 121062 | None | code35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C x 6 mm2 | Mtr | 265.65 | 265.65 | 50.0 | False | None | None | False | None | False | 13282.5 | 0 |
| 3419448 | 121062 | None | code36 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way | Each | 154.35 | 154.35 | 24.0 | False | None | None | False | None | False | 3704.4 | 0 |
| 3419449 | 121062 | None | code37 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Each | 134.4 | 134.4 | 2.0 | False | None | None | False | None | False | 268.8 | 0 |
| 3419450 | 121062 | None | code38 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 3133.2 | 3133.2 | 10.0 | False | None | None | False | None | False | 31332.0 | 0 |
| 3419451 | 121062 | None | code39 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N | Each | 5187.0 | 5187.0 | 1.0 | False | None | None | False | None | False | 5187.0 | 0 |
| 3419452 | 121062 | None | code40 | Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI 70. efficacy 80 lumen per W life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp Wage., short circuit open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K | Each | 447.3 | 447.3 | 18.0 | False | None | None | False | None | False | 8051.4 | 0 |