| 3419694 | 121069 | None | 0001 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle
| Sqm | 4.13 | 4.13 | 20.25 | False | None | None | False | None | False | 83.6325 | 0 |
| 3419695 | 121069 | None | 0002 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 13.59 | False | None | None | False | None | False | 1455.489 | 0 |
| 3419696 | 121069 | None | 0003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6708.45 | 6708.45 | 2.84 | False | None | None | False | None | False | 19051.998 | 0 |
| 3419697 | 121069 | None | 0004 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 5947.2 | 5947.2 | 2.32 | False | None | None | False | None | False | 13797.504 | 0 |
| 3419698 | 121069 | None | 00005 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 6418.44 | 6418.44 | 0.97 | False | None | None | False | None | False | 6225.8868 | 0 |
| 3419699 | 121069 | None | 00005 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11065.25 | 11065.25 | 1.27 | False | None | None | False | None | False | 14052.8675 | 0 |
| 3419700 | 121069 | None | 00007 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10432.95 | 10432.95 | 1.18 | False | None | None | False | None | False | 12310.881 | 0 |
| 3419701 | 121069 | None | 0008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 10939.5 | 10939.5 | 1.77 | False | None | None | False | None | False | 19362.915 | 0 |
| 3419702 | 121069 | None | 0009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates
| Cum | 10276.5 | 10276.5 | 2.88 | False | None | None | False | None | False | 29596.32 | 0 |
| 3419703 | 121069 | None | 000010 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. Buildings
| Tonne | 93929.85 | 93929.85 | 0.81 | False | None | None | False | None | False | 76083.1785 | 0 |
| 3419704 | 121069 | None | 000011 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8367.45 | 8367.45 | 9.26 | False | None | None | False | None | False | 77482.587 | 0 |
| 3419705 | 121069 | None | 00012 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 130412.1 | 130412.1 | 0.239 | False | None | None | False | None | False | 31168.4919 | 0 |
| 3419706 | 121069 | None | 0013 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial
| Sqm | 3155.25 | 3155.25 | 2.52 | False | None | None | False | None | False | 7951.23 | 0 |
| 3419707 | 121069 | None | 00014 | Providing and fixing in position fully glazed for windows shutters with Honne wood stiles and rails of 35mm. thick 75mm wide in single shutters with 4mm thick plain glass fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 5760.3 | 5760.3 | 4.86 | False | None | None | False | None | False | 27995.058 | 0 |
| 3419708 | 121069 | None | 000015 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
| Kg | 192.15 | 192.15 | 102.06 | False | None | None | False | None | False | 19610.829 | 0 |
| 3419709 | 121069 | None | 00016 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Each | 1066.8 | 1066.8 | 1.0 | False | None | None | False | None | False | 1066.8 | 0 |
| 3419710 | 121069 | None | 000017 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Each | 811.65 | 811.65 | 4.0 | False | None | None | False | None | False | 3246.6 | 0 |
| 3419711 | 121069 | None | 00018 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 16.32 | False | None | None | False | None | False | 4129.776 | 0 |
| 3419712 | 121069 | None | 00019 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
| Sqm | 292.95 | 292.95 | 43.52 | False | None | None | False | None | False | 12749.184 | 0 |
| 3419713 | 121069 | None | 000020 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 349.65 | 349.65 | 57.42 | False | None | None | False | None | False | 20076.903 | 0 |
| 3419714 | 121069 | None | 00021 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.
| Sqm | 1622.25 | 1622.25 | 19.96 | False | None | None | False | None | False | 32380.11 | 0 |
| 3419715 | 121069 | None | 00022 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Unit | 143.85 | 143.85 | 59.84 | False | None | None | False | None | False | 8607.984 | 0 |
| 3419716 | 121069 | None | 00024 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 144.9 | 144.9 | 16.61 | False | None | None | False | None | False | 2406.789 | 0 |
| 3419717 | 121069 | None | 00025 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 145.95 | 145.95 | 4.86 | False | None | None | False | None | False | 709.317 | 0 |
| 3419718 | 121069 | None | 00026 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Each | 436800.0 | 436800.0 | 1.0 | False | None | None | False | None | False | 436800.0 | 0 |
| 3419719 | 121069 | None | 00028 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.
| Mtr | 85.05 | 85.05 | 15.0 | False | None | None | False | None | False | 1275.75 | 0 |
| 3419720 | 121069 | None | 00028 | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 82.95 | 82.95 | 15.0 | False | None | None | False | None | False | 1244.25 | 0 |
| 3419721 | 121069 | None | 00029 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box
| Each | 58.8 | 58.8 | 4.0 | False | None | None | False | None | False | 235.2 | 0 |
| 3419722 | 121069 | None | 00030 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm)
| Each | 117.6 | 117.6 | 1.0 | False | None | None | False | None | False | 117.6 | 0 |
| 3419723 | 121069 | None | 00031 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)
| Each | 90.3 | 90.3 | 1.0 | False | None | None | False | None | False | 90.3 | 0 |
| 3419724 | 121069 | None | 00032 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mm
| Each | 77.7 | 77.7 | 1.0 | False | None | None | False | None | False | 77.7 | 0 |
| 3419725 | 121069 | None | 00033 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm)
| Each | 120.75 | 120.75 | 1.0 | False | None | None | False | None | False | 120.75 | 0 |
| 3419726 | 121069 | None | 00033 | FInishing walls with water proofing cement paint of required shade new work to give an even shade after throughly brooming the surgace to remove all dirt dust mortor drops and foreign matter including preparing the surface eve and sand paper smooth cost of materials labour complete as per specifications and as per directions of engineer in charge
| Sqm | 93.45 | 93.45 | 53.0 | False | None | None | False | None | False | 4952.85 | 0 |
| 3419727 | 121069 | None | 00034 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch
| Point | 299.25 | 299.25 | 2.0 | False | None | None | False | None | False | 598.5 | 0 |
| 3419728 | 121069 | None | 00035 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch
| Point | 413.7 | 413.7 | 2.0 | False | None | None | False | None | False | 827.4 | 0 |
| 3419729 | 121069 | None | 00036 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch
| Point | 598.5 | 598.5 | 2.0 | False | None | None | False | None | False | 1197.0 | 0 |
| 3419730 | 121069 | None | 00037 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2
| Mtr | 75.6 | 75.6 | 15.0 | False | None | None | False | None | False | 1134.0 | 0 |
| 3419731 | 121069 | None | 00039 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2
| Mtr | 98.7 | 98.7 | 15.0 | False | None | None | False | None | False | 1480.5 | 0 |
| 3419732 | 121069 | None | 0040 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2
| Mtr | 127.05 | 127.05 | 15.0 | False | None | None | False | None | False | 1905.75 | 0 |
| 3419733 | 121069 | None | 00042 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2
| Mtr | 165.9 | 165.9 | 15.0 | False | None | None | False | None | False | 2488.5 | 0 |
| 3419734 | 121069 | None | 00049 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way
| Each | 154.35 | 154.35 | 2.0 | False | None | None | False | None | False | 308.7 | 0 |
| 3419735 | 121069 | None | 00043 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way
| Each | 134.4 | 134.4 | 2.0 | False | None | None | False | None | False | 268.8 | 0 |
| 3419736 | 121069 | None | 00043 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way
| Each | 108.15 | 108.15 | 2.0 | False | None | None | False | None | False | 216.3 | 0 |
| 3419737 | 121069 | None | 00045 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model
| Each | 3133.2 | 3133.2 | 1.0 | False | None | None | False | None | False | 3133.2 | 0 |
| 3419738 | 121069 | None | 00045 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
| Each | 5187.0 | 5187.0 | 1.0 | False | None | None | False | None | False | 5187.0 | 0 |
| 3419739 | 121069 | None | 00049 | Supplying fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree KCRI70efficacy 80 lumen per W life25000 burning hours and Compliance to IS 10322IEC 60598 LM 79 LM 80 The LED are driven by HF electronic driver integrated in the system, with PF 0.95power loss should 5 of lamp Wage short circuit open circuit protection to be integrated in the circuit, THD less than 20 Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W 6500K
| Each | 447.3 | 447.3 | 3.0 | False | None | None | False | None | False | 1341.9 | 0 |