1719681571000 | 0 | None | None | Other Works | Construction of Toilet building at Valmiki Nagara Govt higher primary school in T Narasipura TMC Limit | 259467.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3419178 | 121043 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work vol-1, SR 2023-24, I.no - 1.14, P.No- 8 | Cum | 105.06 | 105.06 | 10.686 | False | None | None | False | None | False | 1122.67116 | 0 | 3419179 | 121043 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates vol-1, SR 2023-24, I.no - 2.1.2, P.No- 15 | Cum | 5833.92 | 5833.92 | 2.1 | False | None | None | False | None | False | 12251.232 | 0 | 3419180 | 121043 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR.2023-24 Vol-1. I. NO.2.2.3 PAGE NO. 15 | Cum | 7048.16 | 7048.16 | 1.0125 | False | None | None | False | None | False | 7136.262 | 0 | 3419181 | 121043 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR.2023-24 Vol-2. I. NO.5.4 PAGE NO. 9 | Cum | 6580.67 | 6580.67 | 3.252 | False | None | None | False | None | False | 21400.33884 | 0 | 3419182 | 121043 | None | code05 | Providing and laying in position Reinforced cement concrete for all
Sub structures of building, Irrigation works, Sub structure works of
bridges, Drain works & other parallel works from 0.50m to 3.50 m
height. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR.2023-24 . SI. NO.2.4.3 PAGE NO. 17 | Cum | 9789.12 | 9789.12 | 0.474 | False | None | None | False | None | False | 4640.04288 | 0 | 3419183 | 121043 | None | code06 | Supplying, fitting &placing TMT Fe 550/550D steel reinforcement including cost of all materials, machinery, labour, cleaning, straightning, cutting, bending, hooking, laping/welding joints tying with binding wire/soft annealed steel wire and other ancillery operations as per drawing and technical specifications. vol-1, SR 2023-24, I.no - 2.11(a), P.No- 18 | Tonne | 92140.71 | 92140.71 | 0.334 | False | None | None | False | None | False | 30774.99714 | 0 | 3419184 | 121043 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CM SR.2023-24 .VOL-1, SI. NO.2.5.2 PAGE NO. 16 | Cum | 11982.09 | 11982.09 | 0.608 | False | None | None | False | None | False | 7285.11072 | 0 | 3419185 | 121043 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CM SR.2023-24 .VOL-1, SI. NO.2.5.2 PAGE NO. 16 | Cum | 10572.43 | 10572.43 | 2.26 | False | None | None | False | None | False | 23893.6918 | 0 | 3419186 | 121043 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. vol-2, SR 2023-24, I.no -6.34 , P.No-17 | Cum | 1137.12 | 1137.12 | 49.76 | False | None | None | False | None | False | 56583.0912 | 0 | 3419187 | 121043 | None | code10 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. PWD CM SR.2023-24 . Vol -2 SI . NO .8.3.1 PAGE NO. 41 | Sqm | 364.62 | 364.62 | 11.265 | False | None | None | False | None | False | 4107.4443 | 0 | 3419188 | 121043 | None | code11 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CM SR.2023-24 . Vol -2 SI . NO .8.1.1 PAGE NO. 41 | Sqm | 262.65 | 262.65 | 17.41 | False | None | None | False | None | False | 4572.7365 | 0 | 3419189 | 121043 | None | code12 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Below roof ht 3.00+roof thickness 0.15+plinth 0.45=3.60M PWD CM SR.2023-24 . Vol -2 SI . NO .8.3.1 PAGE NO. 41 | Sqm | 364.62 | 364.62 | 39.9525 | False | None | None | False | None | False | 14567.48055 | 0 | 3419190 | 121043 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD SR.2021-22 . Vol -2 SI. NO.11.34A PAGE NO. 86 | Sqm | 173.04 | 173.04 | 19.845 | False | None | None | False | None | False | 3433.9788 | 0 | 3419191 | 121043 | None | code14 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD SR.2023-24 . Vol -2 SI . NO11.5.1 PAGE NO. 77 | Sqm | 4612.34 | 4612.34 | 3.69 | False | None | None | False | None | False | 17019.5346 | 0 | 3419192 | 121043 | None | code15 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. CSR-2023-24, Vol-2,I No-9.11, P No-60 | Sqm | 915.67 | 915.67 | 6.48 | False | None | None | False | None | False | 5933.5416 | 0 | 3419193 | 121043 | None | code16 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CM SR.2023-24 Vol -2 SI . NO .8.27 PAGE NO. 45 | Sqm | 54.59 | 54.59 | 68.6275 | False | None | None | False | None | False | 3746.375225 | 0 | 3419194 | 121043 | None | code17 | Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CM SR.2023-24 Vol -2 SI . NO .8.39 PAGE NO. 48 | Sqm | 130.81 | 130.81 | 28.675 | False | None | None | False | None | False | 3750.97675 | 0 | 3419195 | 121043 | None | code18 | Finishing walls with Acrylic Smooth exterior paint of required shade
:New work (Two coat applied @ 1.67 ltr/10 m² over and including
priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint
of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CM SR.2023-24 Vol -2 SI . NO .8.30 PAGE NO. 46 | Sqm | 179.22 | 179.22 | 39.9525 | False | None | None | False | None | False | 7160.28705 | 0 | 3419196 | 121043 | None | code19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR.2021-22 Vol -2 SI . NO .8.41 PAGE NO. 48 | Sqm | 172.01 | 172.01 | 4.64 | False | None | None | False | None | False | 798.1264 | 0 | 3419197 | 121043 | None | code20 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC
foam sheet metered cut at corners & jointed 2 No.s of 150mm
long brackets of 15x15mm M.S Square tube, the entire door frame to
be reinforced with 19x19mm M.S Square tube of 19 gauge. The door
frame to be fixed to the wall using M.S. Screws of 65/80mm size completeas per manufacturers specification & direction of Engineer-in-charge. PWD CM SR.2023-24 . Vol -2 SI. NO.12.54 PAGE NO. 105 | m | 327.54 | 327.54 | 6.9 | False | None | None | False | None | False | 2260.026 | 0 | 3419198 | 121043 | None | code21 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam PWD CM SR.2023-24 . Vol -2 SI. NO.12.55.1 PAGE NO. 104 | Mtr | 2436.98 | 2436.98 | 3.0749 | False | None | None | False | None | False | 7493.469802 | 0 | 3419199 | 121043 | None | code22 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Nos | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 | 3419200 | 121043 | None | code23 | Providing and fixing white vitreious back flat or wall corner type lipped front urinal basin of 430x260x350mm & 350x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe & cp brass spreaders with brass unions & GI clamps complete including painting of fitting & brackets, cutting & making good the walls & floors wherever required CSR-2023-24, Vol-2,I No-14.4, P No-131 | Nos | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 |
|