createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719656663730
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee740.00
emd59200.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-07-2024 17:30:00
tenderQueryClose06-07-2024 14:00:00
technicalBidOpen10-07-2024 11:00:00
publishedDate29-06-2024 17:39:29
publishedByPostBMTC_EE_HOFF_BNG
publishedByUserKPE14985 - RANGARAJU B P
bidValidityPeriod180
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonNarasimhamurthy
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022537447
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719656663758
version4
createdDateNone
modifiedDateNone
tenderNumberBMTC/2024-25/BD/WORK_INDENT61
titleConstruction of Ladies Crew rest room & Toilet Block at Depot - 06, Indiragara, Bengaluru (2nd Call)
descriptionConstruction of Ladies Crew rest room & Toilet Block at Depot - 06, Indiragara, Bengaluru (2nd Call)
categoryWORKS
categoryTextWorks
ecv2956955.09
deptNameBangalore Metropolitan Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location3586
locationNameBangalore Metropolitan Transport Corporation Office Bengaluru
provisionalAmount2957000.0
groupOverheadTotal451060.95
fileNumber432A
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17196566640000NoneNoneBuildingsConstruction of Ladies Crew rest room & Toilet Block at Depot - 06, Indiragara, Bengaluru (2nd Call)2505894.14
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3414513120799Nonecode01KSRB 2-1.1 Earth work surface excavation in ordinary soil for leveling and lowering the ground manually (other than foundation o buildings, culverts, road drains and trenches of pipe lines and cables) and removing the excavated stuff to a distance not exceeding 50m and lift upto 1.5m excavated surface leveled and neatly dressed as per specifications. Specification No.KBS 2.1(a)/2.3.1 P- 5/2.1.Cum268.92268.9223.1FalseNoneNoneFalseNoneFalse6212.0520
3414514120799Nonecode02KSRB 2-2.1 : Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 (Page 5/Item no. 2.3).Cum322.92322.92229.94FalseNoneNoneFalseNoneFalse74252.22480
3414515120799Nonecode03KSRRB M200-12.3. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres complete as per specifications. i) Lime /Cement Concrete. I. By Manual Means :A. Lime Concrete, cement concrete grade M-10 and below. MORTH Specification No. 202 (Page.139/Item No.18.17)Reinforced cement concrete grade M-20 & above. (Page.139/Item No.18.19).Cum1716.121716.1225.25FalseNoneNoneFalseNoneFalse43332.030
3414516120799Nonecode04KSRB 2.8 Filling in foundation with granite/trap broken metal 100mm and down size with approved sand including hand packing, ramming, watering, including cost of all materials and labour with lead upto 50m and lift of 1.5m complete as per specifications. P - 6/2.15.Cum2623.322623.3217.42FalseNoneNoneFalseNoneFalse45698.23440
3414517120799Nonecode05KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix M7.5 with opc cement@180kgs with 40mm and down size graded granite metal, coarse aggregates @ 0.57cum machine mixed, concrete laid in layers not f exceeding 15 cms thick well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing compete as per specifications. Specification No.KBS 4.1, 4.2 P- 12/4.3Cum5510.165510.1615.09FalseNoneNoneFalseNoneFalse83148.31440
3414518120799Nonecode06KSRB 5.2-3 Providing and constructing granite/trap/basalt size stone masonry in foundation cement mortar 1:6, stone hammered dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per Specifications(P-22/5.6).Cum4963.684963.689.07FalseNoneNoneFalseNoneFalse45020.57760
3414519120799Nonecode07KSRB 5.3-3 Providing and constructing granite/trap/basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 P - 21/5.9.Cum5921.645921.6410.42FalseNoneNoneFalseNoneFalse61703.48880
3414520120799Nonecode08KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. (Page -6/Item no.2.10).Cum217.08217.08188.36FalseNoneNoneFalseNoneFalse40889.18880
3414521120799Nonecode09KSRB 4.9.2 : Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour HOM of machinery complete as per specifications. Specification No.KBS 4.6.3 P 17/4.46 TMT bars Fe 500. p-17/4.46.2.MT76643.2876643.284.56FalseNoneNoneFalseNoneFalse349493.35680
3414522120799Nonecode10KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 (Page.15/Item No.4.28).Sqm278.64278.6456.0FalseNoneNoneFalseNoneFalse15603.840
3414523120799Nonecode11KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per Specification No. KBS 4.6.2 (Paged.17/Item No.4.32).Sqm492.48492.4869.44FalseNoneNoneFalseNoneFalse34197.81120
3414524120799Nonecode12KSRB 4-6.7 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specificaitons (Page.16/Item 4.34).Sqm315.36315.369.6FalseNoneNoneFalseNoneFalse3027.4560
3414525120799Nonecode13KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 (Page.16/Item No.4.29.2 0 to 5mts).Sqm432.0432.060.0FalseNoneNoneFalseNoneFalse25920.00
3414526120799Nonecode14KSRB 4-6.9 :Providing and removing centering, shuttering, strutting,propping etc, for edges of slabs and breaks in floor, cills, plinth including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 (Page.17/Item 4.36).Sqm815.4815.44.5FalseNoneNoneFalseNoneFalse3669.30
3414527120799Nonecode15KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6(P-13/4.10).Cum6276.966276.9626.32FalseNoneNoneFalseNoneFalse165209.58720
3414528120799Nonecode16KSRB 4-2.3: Providing and laying in position Reinforced Cement Concrete of mix M25 with OPC cement @ 240 Kgs with 20mm and down size graded granite metal of coarse aggregates @ 0.878 cum and fine aggregates @ 0.459 cum, with superplastisiser @ 3 Ltrs conforming to IS 9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintels, retaining walls, return walls, walls (any thickness) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing complete as per Specification No. KBS 4.1, 4.6 (Page - 13/ Item no.4.12).Cum6528.66528.617.58FalseNoneNoneFalseNoneFalse114772.7880
3414529120799Nonecode17KSRB 4-2.10: Providing and laying in position Reinforced Cement Concrete of mix M-20 with OPC cement @ 24Kgs with 12mm and down size graded granite metal coarse aggregates @ 0.5175 cum and fine aggregates @ 0.345 cum, with superplastisiser @ 0.225 Ltrs, machine mixed, well compacted for Plain chajja of 7.5cms average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, curing complete as per Specification No. KBS 4.1, 4.6(Page - 15/ Item no.4.19).Sqm475.2475.28.52FalseNoneNoneFalseNoneFalse4048.7040
3414530120799Nonecode18KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 (Page.16/Item 4.37).Sqm348.84348.848.52FalseNoneNoneFalseNoneFalse2972.11680
3414531120799Nonecode19Providing and construction of stabilized mud block masonry walls with blocks of minimum strength of 35kg/sqcm and laid using 3/4" thick 1:5:5 (Cement : Soil : Quarry dust mixed with lime water) stabilized mud mortar. Concealed electrical works as specified in the drawings shall be carried out during the masonary wall process, Work includes lifting & placing of blocks, packing and raking out joints at all heights with proper curing, cost of labour, equipment and machinery/ fuel, scaffolding all leads and lifts and other incidental charges. Note: 1. Blocks to be rejected if noticed broken, chipped or damaged while stacking; 2. Block test report to be presented to architect and client before starting the walls at site. 3.Test to be done at contractor's cost. (Required strength of blocks with 7% stabilisation).Sft185.0185.0500.0FalseNoneNoneFalseNoneFalse92500.00
3414532120799Nonecode20KSRB 6-2.2 Providing and constructing burnt brick masonry with approved quality of non-modular bricks of standard size of class designation 50 (table moulded) with CM 1:6 for basement and superstructure including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification KBS 6.2 P 27/6.6.Cum7245.727245.7233.64FalseNoneNoneFalseNoneFalse243746.02080
3414533120799Nonecode21KSRB 6-8.2 : Construction of partition wall 10 cms thick with table moulded modular burnt bricks of class designation 5.0Newton per sqmm with cement mortar 1:4 including providing and fixing plaster mesh manufactured out of hot dipped gelvanised iron of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2P-29/6.28.Sqm887.76887.7629.05FalseNoneNoneFalseNoneFalse25789.4280
3414534120799Nonecode22KSRB 7.9 Providing and fixing MS grill work for windows and ventilators weighing 21kg/sqm using MS flats, or M.S square rods, or combination of M.S flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No.KBS 7.12 P 32/7.9.Kg102.6102.6264.6FalseNoneNoneFalseNoneFalse27147.960
3414535120799Nonecode23KSRB 7.14 : Providing, fabricating, assembling and fixing in position anodized aluminium partitions using sections in combination of plain, single grove and double grove as per requirements for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections 2.40kg/m single grove section 2.541kg/m. and double grove section 2.683 kg/m and bottom member 114.3mmx44.45mm 3.18mm thick weight 2.646 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet both side of approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistling and making good with with cement mortar to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight 0.124kg/m; aluminium sections anodised 12 to 15 microns, sections pre-treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable size holes and fixing with cement mortar, with necessary opening for fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. (Page.35/Item No.7.14.2)Powder coated.Sqm5178.65178.64.2FalseNoneNoneFalseNoneFalse21750.120
3414536120799Nonecode24KSRB 7.17 : Providing, fabricating, assembling and fixing in position anodized aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections anodized 12 to 15 microns cut to length joint metred corners grinded, the shutters ugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. (Page.37/7.17.2)Powder coatedSqm6717.66717.62.52FalseNoneNoneFalseNoneFalse16928.3520
3414537120799Nonecode25KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar.P-35/7.112 -do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.Sqm4789.84789.89.0FalseNoneNoneFalseNoneFalse43108.20
3414538120799Nonecode26KSRB 9.4-3 Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as per specifications. P - 51/9.12.Cum68479.5668479.560.05FalseNoneNoneFalseNoneFalse3423.9780
3414539120799Nonecode27Providing and fixing factory made single leaft rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized Isopthalic Gelcoat and on layer of 450 gsm E-Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to RV/TIFAC Composites Design centre Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot (Page.59/Item No.9.93)Sqm3240.03240.01.68FalseNoneNoneFalseNoneFalse5443.20
3414540120799Nonecode28Providing and fixing of factory made 30mm PVC rigid foam PANEL DOORS Rajashree made from MS Tube of 19 guage size of 19mm x 19mm and convered with heat moulded PVC C channel and width of 50mm to form styles and rails. The inner panel should be inserted in between the frame with 5mm thick PVC rigid foam sheet welded/ sealed to te styles and rails along with 5mm PVC, beeding on all and either sides. The vertical tubes may be tiled with suyitable wood materials to further enhance the screw holding capacity. (P 63/ 9.91)with PVC Door frame. [P 62/9.91]Sqm2592.02592.06.3FalseNoneNoneFalseNoneFalse16329.60
3414541120799Nonecode29Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. Square tube. The two vertical door profiles are to be reinforced with 19x19 mm M.S. Square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door screws through the frame by using PVC fasteners. A minimum of 4 Nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member. (Page.63/Item No.9.92)Mtr388.8388.820.0FalseNoneNoneFalseNoneFalse7776.00
3414542120799Nonecode30KSRB15-3.5 : Providing 15mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications (Page.113/Item 15.13)Sqm238.68238.68162.36FalseNoneNoneFalseNoneFalse38752.08480
3414543120799Nonecode31KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications ((Page.114/Item 15.22).Sqm243.0243.044.1FalseNoneNoneFalseNoneFalse10716.30
3414544120799Nonecode32KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications (Page.113/15.16).Sqm281.88281.88155.0FalseNoneNoneFalseNoneFalse43691.40
3414545120799Nonecode33KSRB15-7 : Providing lime rendering for plastering to wall and ceiling , including cost of materials, labour, curing complete as per specifications (Page.115/Item 15.33)Sqm34.5634.56206.46FalseNoneNoneFalseNoneFalse7135.25760
3414546120799Nonecode34KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications (Page.113/15.30).Sqm221.4221.447.04FalseNoneNoneFalseNoneFalse10414.6560
3414547120799Nonecode35KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level, P.V.C flushing cistern (all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11( P-79/12.2)Pan4561.924561.923.0FalseNoneNoneFalseNoneFalse13685.760
3414548120799Nonecode36Providing and fixing white vitreous china clay surgeon type Wash basin size 660x460mm with a pair of 15mm C.P.brass pillar taps with pair of elbow operated levers, C.I. / M.S. brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials labour complete as per specifications [P-78/12.31] (Ovel Shaped).Unit4408.564408.562.0FalseNoneNoneFalseNoneFalse8817.120
3414549120799Nonecode37Providing stone ware Nahanitrap of approved quality and make confirming to isi speifications, Construction of cistern in m- 15 as per directions wherever necessary (rate includes cost of all materials, fixtures and lead) 10 cm x 7.50 cm [P-88/12.113.1]Nos270.0270.06.0FalseNoneNoneFalseNoneFalse1620.00
3414550120799Nonecode38Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, (clear inside dimension) for pipeline, using table moulded non-modular bricks of class designation 50 in CM 1:5, CI cover with frame (light duty) 600x600mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) RCC top slab with CC 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with CM 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specification.( P -73/11.50.1)No7629.127629.123.0FalseNoneNoneFalseNoneFalse22887.360
3414551120799Nonecode39Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, (clear inside dimension) for pipeline, using table moulded non-modular bricks of class designation 50 in CM 1:5, CI cover with frame (light duty) 600x600mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) RCC top slab with CC 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with CM 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specification. (P -73/11.50.2)No9169.29169.24.0FalseNoneNoneFalseNoneFalse36676.80
3414552120799Nonecode40Providing and fixing two in one Bib cock 041 JAGUAR- continental make of with all accessories fixing etc., complete as per specifications and directions of the Engineer -incharge of the work.For other toilets & For other toilet & gents toilet. ( Approved shivajinagar Bus station works).No950.0950.08.0FalseNoneNoneFalseNoneFalse7600.00
3414553120799Nonecode41KSRB 11-11.7 Providing and fixing 1500x450mm rectangular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of materials, labour complete as per specifications.[ P- 80/12.43]No1599.481599.482.0FalseNoneNoneFalseNoneFalse3198.960
3414554120799Nonecode42KSRB 13-6.6-1 Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. ( P -89/13.47 )Set285.12285.124.0FalseNoneNoneFalseNoneFalse1140.480
3414555120799Nonecode43JAGUAR make, cat No.SOL-6357 , Providing and fixing sink cock with regular swinging spout for pantry sinks with all accessories fixing etc., complete as per specifications and directions of the Engineer -incharge of the workNo4482.884482.882.0FalseNoneNoneFalseNoneFalse8965.760
3414556120799Nonecode44KSRB 13-6.3-2 Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No. KBS 13.2.6/13.3 ( P -91/13.33)Each362.88362.883.0FalseNoneNoneFalseNoneFalse1088.640
3414557120799Nonecode45KSRB 13-6.3-2 Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No. KBS 13.2.6/13.3 (P -91/13.34)Each484.92484.922.0FalseNoneNoneFalseNoneFalse969.840
3414558120799Nonecode46KSRB 13-6.3-2 Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 32 mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No. KBS 13.2.6/13.3 ( P- 89/13.36)Each1123.21123.22.0FalseNoneNoneFalseNoneFalse2246.40
3414559120799Nonecode47Providing and laying plat form using prepolished, water cut / gang saw 40mm thick telephonic Black Granite. laid on existing vertical -supports and fixing in CM 1:3 proportion. Including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including curing. (P - 108/14.52)Sqm3533.343533.340.78FalseNoneNoneFalseNoneFalse2756.00520
3414560120799Nonecode48Providing full nosing of 40 mm th granite slab using req machinery including and conveyance of all materials , labour for all items of work, Hom of equipments etc , complete P- 108/14.53Mtr548.34548.342.5FalseNoneNoneFalseNoneFalse1370.850
3414561120799Nonecode49KSRB 11-17-1: Providing and fixing C.P. brass towel rail 740mm length, 20mm dia with C.P. brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, labour complete as per specifications. ( P-83/12.45)Each798.12798.121.0FalseNoneNoneFalseNoneFalse798.120
3414562120799Nonecode50KSRB 10-3 : Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications. (Page.66/Item No.10.2)Sqm1073.521073.5260.0FalseNoneNoneFalseNoneFalse64411.20
3414563120799Nonecode51Providing vitrified tiles 60 x 60cms of(granomite finish) approved make, shade and size for flooring laid on a 12mm thick cement mortar 1:3 mix, flush pointing with white cement using colour pigment, including cost of materials, labour, curing complete as per specifications. [P-107/14.43]Sqm1186.921186.9289.92FalseNoneNoneFalseNoneFalse106727.84640
3414564120799Nonecode52Providing and laying flooring Ruby Red / Hassan green/ Grey/Black granite /Multy red using pre polished 19mm thick water cut/gang saw Granite slab over existing CC bed in 1:4 average 20mm thick pointed with white cement/colour pigment etc complete. P 107/14.47.1 Width not less than 1200 mmSqm2458.082458.083.04FalseNoneNoneFalseNoneFalse7472.56320
3414565120799Nonecode53KSRB4-16 Providing and laying in position plain cement concrete of mix 1:2:4 using 20mm down size KSRB graded granite metal, machine mixed, concrete laid in layers not exceeding 15cm thick well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications Specification No.KBS 4.1,4.2(P-12/4.6)Cum5855.765855.764.28FalseNoneNoneFalseNoneFalse25062.65280
3414566120799Nonecode54KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) (Page.94/I.No.13.78)Nos7374.247374.242.0FalseNoneNoneFalseNoneFalse14748.480
3414567120799Nonecode55Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the sueface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification[P-125/15.106].Sqm84.2484.24206.46FalseNoneNoneFalseNoneFalse17392.19040
3414568120799Nonecode56KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after throughly brushing the surface, free from m ortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications (Page.116/Item 15.51.2)do- with primerSqm97.297.2206.46FalseNoneNoneFalseNoneFalse20067.9120
3414569120799Nonecode57KSRB 15-16.1 : Providing and finishing external walls in two coats with waterproof Apex paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications.with primer coat.Sqm125.0125.0250.0FalseNoneNoneFalseNoneFalse31250.00
3414570120799Nonecode58KSRB 15-18.2 : Providing and applying enamel metal paint two coats (excluding priming coat) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter,including cost of materials, labour, complete as per specifications (Page.128/Item No.15.74)Sqm102.6102.640.0FalseNoneNoneFalseNoneFalse4104.00
3414571120799Nonecode59Fabricating, supplying & erecting M.S. angular Truss for all spans as per approved designs and drawing. The entire truss is anchored in RCC column by using 4 Nos. of M.S. anchor bolts at each support, with 10mm thick base plate and shoe plate.The work includes cutting, straightening, placing in position of M.S angle and wleding wherever necessary, and applying one coat of red oxide primer coat to all the members including cost of all materials, labour charges, & hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification. (Page No. 40 Item No. 7.30 of CSR 2015-16).Kg135.68135.68229.97FalseNoneNoneFalseNoneFalse31202.32960
3414572120799Nonecode60Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (Internal work exposed on wall) (Page.96/Item No.13.85.1) 20mm dia.Mtr140.4140.430.0FalseNoneNoneFalseNoneFalse4212.00
3414573120799Nonecode61do 25mm diaMtr211.68211.6830.0FalseNoneNoneFalseNoneFalse6350.40
3414574120799Nonecode62do 32mm diaMtr274.32274.3265.0FalseNoneNoneFalseNoneFalse17830.80
3414575120799Nonecode63Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 6.00 kgf/sq.cm working pressure with pipe fitting, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of aquirements and testing complete as per specifications.160 mm dia ( P-85/12.116.1).110mm diaMtr468.72468.7230.0FalseNoneNoneFalseNoneFalse14061.60
3414576120799Nonecode64140mm diaMtr743.04743.0485.0FalseNoneNoneFalseNoneFalse63158.40
3414577120799Nonecode65Removal of debries up to 10.0 km including loading and unloading.Cum142.56142.56129.08FalseNoneNoneFalseNoneFalse18401.64480
3414578120799Nonecode66Electrical works:-Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr65.065.0300.0FalseNoneNoneFalseNoneFalse19500.00
3414579120799Nonecode67Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mmMtr28.028.0100.0FalseNoneNoneFalseNoneFalse2800.00
3414580120799Nonecode68Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxPoint160.0160.014.0FalseNoneNoneFalseNoneFalse2240.00
3414581120799Nonecode69Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint250.0250.010.0FalseNoneNoneFalseNoneFalse2500.00
3414582120799Nonecode70Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint375.0375.012.0FalseNoneNoneFalseNoneFalse4500.00
3414583120799Nonecode71Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmmMtr20.520.5500.0FalseNoneNoneFalseNoneFalse10250.00
3414584120799Nonecode722.5 sqmmMtr32.032.01000.0FalseNoneNoneFalseNoneFalse32000.00
3414585120799Nonecode734 sqmmMtr45.045.0200.0FalseNoneNoneFalseNoneFalse9000.00
3414586120799Nonecode74Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3WayEach85.085.06.0FalseNoneNoneFalseNoneFalse510.00
3414587120799Nonecode756WayEach115.0115.04.0FalseNoneNoneFalseNoneFalse460.00
3414588120799Nonecode7610-12WayEach160.0160.06.0FalseNoneNoneFalseNoneFalse960.00
3414589120799Nonecode77Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach110.0110.06.0FalseNoneNoneFalseNoneFalse660.00
3414590120799Nonecode786 ModuleEach175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
3414591120799Nonecode7910-12 ModuleEach230.0230.06.0FalseNoneNoneFalseNoneFalse1380.00
3414592120799Nonecode80Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way SwitchEach70.070.0100.0FalseNoneNoneFalseNoneFalse7000.00
3414593120799Nonecode816Amps 3way socketEach105.0105.025.0FalseNoneNoneFalseNoneFalse2625.00
3414594120799Nonecode8232Amps DP switchEach182.0182.06.0FalseNoneNoneFalseNoneFalse1092.00
3414595120799Nonecode83TV/Telephone socketEach79.079.04.0FalseNoneNoneFalseNoneFalse316.00
3414596120799Nonecode84Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SPEach434.0434.010.0FalseNoneNoneFalseNoneFalse4340.00
3414597120799Nonecode856-32Amps DPEach909.0909.08.0FalseNoneNoneFalseNoneFalse7272.00
3414598120799Nonecode86Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.1- Single Door12Way SP &NEach1210.01210.04.0FalseNoneNoneFalseNoneFalse4840.00
3414599120799Nonecode87Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm)Each2100.02100.06.0FalseNoneNoneFalseNoneFalse12600.00
3414600120799Nonecode88Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W plus- minus 10 percentage, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 plus-minus 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48 inch Sweep 5 Star (1200mm)Each2900.02900.06.0FalseNoneNoneFalseNoneFalse17400.00
3414601120799Nonecode89Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIgreater 70percentage. efficacy greater100 lumen per watt, 120degree beam spread, lifegreater 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater 0.95, power loss shouldlesser 5percentage of lamp wattage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition15-18WEach2000.02000.010.0FalseNoneNoneFalseNoneFalse20000.00
3414602120799Nonecode90Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater 70percentage. efficacy greater 100 lumen per watt, 120degree beam spread, lifegreater 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater 0.95, power loss shouldlesser 5percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1 x1 inch 34 -22wattsNo2642.02642.010.0FalseNoneNoneFalseNoneFalse26420.00
3414603120799Nonecode91Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70 percentage lumen maintenance with CRI greater 80. Power Input: 220-240V@ 50/60Hz & Power factor greater 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4inch- 20/22 wEach375.0375.018.0FalseNoneNoneFalseNoneFalse6750.00
3414604120799Nonecode92Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / GirdersEach110.0110.038.0FalseNoneNoneFalseNoneFalse4180.00
3414605120799Nonecode93Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each150.0150.06.0FalseNoneNoneFalseNoneFalse900.00
3414606120799Nonecode94Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each650.0650.04.0FalseNoneNoneFalseNoneFalse2600.00
3414607120799Nonecode95Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo2999.72999.72.0FalseNoneNoneFalseNoneFalse5999.40
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17196566650000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17196566650000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17196566650000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17196566650000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17196566650000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17196584060000NoneNoneELIGIBILITYAll terms & condition as per tender notification & KW standard documents.None
17196584310000NoneNoneELIGIBILITYAny misprint in units or specification to be read as per the relevant PWD SRNone
17196584600000NoneNoneELIGIBILITYThe Contractor has to quote the rates including GST in the tenderNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneShould be valid registered Civil Contractors / Firms in Karnataka CPWD/MES/KPWDOthersRegistration Certificate.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration Certificate.
NoneNoneNoneNoneWork-done Certificate for having satisfactorily completed as a prime contractor for at least one similar nature of Building work not less than 50% of amount put to tender in last previous five years in any of the Government / Public Sector Undertaking i.e (2019-20, 2020-21, 2021-22,2022-23 & 2023-24)OthersWorkdone certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate
NoneNoneNoneNoneShould have achieved in at least two financial years an average annual financial turnover of not less than the amount put to tender pertaining to works out of five financial years (2019-20, 2020-21, 2021-22,2022-23 & 2023-24)OthersTurnover certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Turnover certificate
NoneNoneNoneNoneLiquid assets and availability of credit facilities of not less than 30 % of the equivalent of the amount put to tenderOthersLine of credit
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Line of credit
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:OthersBid Capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bid Capacity
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
As per eligibility criteriaTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone