3415983 | 120888 | None | code01 | Providing and construction of stabilized mud block masonry walls with blocks of minimum strength of 35kg/sqcm and laid using 3/4" thick 1:5:5 (Cement : Soil : Quarry dust mixed with lime water) stabilized mud mortar. Concealed electrical works as specified in the drawings shall be carried out during the masonary wall process, Work includes lifting & placing of blocks, packing and raking out joints at all heights with proper curing, cost of labour, equipment and machinery/ fuel, scaffolding all leads and lifts and other incidental charges.
Note:
1. Blocks to be rejected if noticed broken, chipped or damaged while stacking;
2. Block test report to be presented to architect and client before starting the walls at site.
3.Test to be done at contractor's cost. (Required strength of blocks with 7% stabilisation ) | Sft | 185.0 | 185.0 | 810.5 | False | None | None | False | None | False | 149942.5 | 0 |
3415984 | 120888 | None | code02 | KSRB 6-1 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqm with cement mortar including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2KSRB 6-1.3 : - do - with cement mortar 1:6 | Cum | 5622.48 | 5622.48 | 75.27 | False | None | None | False | None | False | 423204.0696 | 0 |
3415985 | 120888 | None | code03 | KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of Design Mix M25 with OPC @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70 cum and fine aggregtes @ 0.47cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008 at machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columns pillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1,( P-14/4.10) first floor | Cum | 6276.96 | 6276.96 | 7.79 | False | None | None | False | None | False | 48897.5184 | 0 |
3415986 | 120888 | None | code04 | KSRB 4-1.1: Providing and laying in position plain cement concrete of Mix 1:2:4 with OPC @ 240kgs, with 40mm and down size graded granite metal coarse aggregates @0.878 cum and fine aggregates @ 0.459 cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM curing complete as per specifications. Specification No. KBS 4.1, 4.2 | Cum | 5705.64 | 5705.64 | 12.0 | False | None | None | False | None | False | 68467.68 | 0 |
3415987 | 120888 | None | code05 | KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels, and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns,pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 | Cum | 6363.36 | 6363.36 | 15.0 | False | None | None | False | None | False | 95450.4 | 0 |
3415988 | 120888 | None | code06 | KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 | Sqm | 432.0 | 432.0 | 80.0 | False | None | None | False | None | False | 34560.0 | 0 |
3415989 | 120888 | None | code07 | KSRB 4.9.2 : Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour HOM of machinery complete as per specifications. Specification No.KBS 4.6.3 P 17/4.46 TMT bars Fe 500. P-18/4.46.2. | MT | 76643.28 | 76643.28 | 2.26 | False | None | None | False | None | False | 173213.8128 | 0 |
3415990 | 120888 | None | code08 | Providing & fixing factory made Galvanized steel door Shutters 32 mm thick manufactured from pre- painted Aluminium-zinc metallic coated steel sheet 0.60 mm thick conforming to the IS: 15961. The door shutters consist of two outer skins of steel sheets, lock seam jointed at vertical stile edges, horizontal top & bottom sides to form a double skin fully flush shell. Rigid polyurethane Foam (PUF) of density 40 Kg/M3 shall be filled in the hollow portion of door shutters for structure rigidly & sound insulation. The necessary stiffeners of Galvanized plain steel sheet of minimum thickness 1.60 mm to be provided for all hardware fixtures. The rate is including transportation, loading, unloading, HOM etc. but excluding the hardware fixtures. Size 650 x 2035 x 32 mm thick.( 38.50.3) | Sqm | 2700.0 | 2700.0 | 1.5 | False | None | None | False | None | False | 4050.0 | 0 |
3415991 | 120888 | None | code09 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for styles and 15x15mm for top & bottom rails, covered with heat moulded PVC channel of 5mm thick sheet & 30 x 50mm wide to form styles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the styles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 m.m Aluminium hinges. ( 9.83) | Sqm | 2999.16 | 2999.16 | 8.18 | False | None | None | False | None | False | 24533.1288 | 0 |
3415992 | 120888 | None | code10 | KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arr angement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications.powder coated (P-39/ 7.17.2) | Sqm | 6717.6 | 6717.6 | 3.9 | False | None | None | False | None | False | 26198.64 | 0 |
3415993 | 120888 | None | code11 | KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM complete as per specifications. Specification No. KBS 7.12 ( 7.9) | Kg | 102.6 | 102.6 | 420.0 | False | None | None | False | None | False | 43092.0 | 0 |
3415994 | 120888 | None | code12 | SRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. ( 7.11.2) -do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. | Sqm | 4389.84 | 4389.84 | 25.0 | False | None | None | False | None | False | 109746.0 | 0 |
3415995 | 120888 | None | code13 | KSRB15-3 : Providing 18mm thick cement plaster in single coat with cement mortar to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-3.8 : do cement mortar 1:4 ( 15.16) | Sqm | 281.88 | 281.88 | 30.0 | False | None | None | False | None | False | 8456.4 | 0 |
3415996 | 120888 | None | code14 | KSRB 15.1.3 do Providing ruled pointing 20 mm deep to coursed stone masonry with cement mortar after raking joints to depth of 20mm nicely lining, including cost of materials, labour, curing complete as per specifications.( 15.3) | Sqm | 153.36 | 153.36 | 545.63 | False | None | None | False | None | False | 83677.8168 | 0 |
3415997 | 120888 | None | code15 | Providing and applying composite water proofing compound as impregnate only on wet surfaces to arrest leaks in surfaces such as roof cealing, internal and external walls, flooring and other surfaces apart from water tanks, sumps, reservoirs, by mixing the composite waterproofing compound with water in ratio of 1:10 to make a workable slurry and pouring it on all cleaned and prepared corners and disturbed area and further mixing in the ratio 1:20 AND pouring it on the prepared surface by cleaning the surface with etchant chemical from dirt foreign materials etc., and allowing it to be there upto 3 hours and then cleaning the same using water complete as per specification so that the surface is got back and ready to use after 4 hours.( P-69/10.8) | Sqm | 623.16 | 623.16 | 24.45 | False | None | None | False | None | False | 15236.262 | 0 |
3415998 | 120888 | None | code16 | KSRB 10-3 : Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment.(b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications.( P-68/10.2) | Sqm | 1073.52 | 1073.52 | 32.24 | False | None | None | False | None | False | 34610.2848 | 0 |
3415999 | 120888 | None | code17 | KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.( P-48/8.4) | Cum | 2154.6 | 2154.6 | 3.9 | False | None | None | False | None | False | 8402.94 | 0 |
3416000 | 120888 | None | code18 | Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of approved make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special adhesive for flooring, skirting and jointed with neat cement slurry mixed with pigment to match shade of tiles, including providing spacers at required interval and removing stains etc., cost of materials, mortar, labour etc., complete as per specification. | Sqm | 972.0 | 972.0 | 50.0 | False | None | None | False | None | False | 48600.0 | 0 |
3416001 | 120888 | None | code19 | KSRB 14-16.2 : Providing red oxide skirting upto 30 cms. height with cement mortar 1:3 including rounding off junctions with floor, finished overall 15 mm thick, top portion 5mm thick mixed with red oxide and a floating coat of neat cement using 3.5kg of red oxide of iron per 50 kg of cement including cost of materials, labour, complete as per specifications. Specification No.KBS 14.5 | Sqm | 368.28 | 368.28 | 10.6 | False | None | None | False | None | False | 3903.768 | 0 |
3416002 | 120888 | None | code20 | KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. Specification No. KBS Ceramic Tiles of size 30x30cms 6mm thick ( P-108/14.36.2) | Sqm | 1306.8 | 1306.8 | 11.8 | False | None | None | False | None | False | 15420.24 | 0 |
3416003 | 120888 | None | code21 | KSRB 14-17.2 : Providing skirting, dadoing, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17Colour glazed tiles 30x45 cms 6mm thick with border of size 30 x 10 cms.( P-108/14.41.3) | Sqm | 1377.0 | 1377.0 | 25.0 | False | None | None | False | None | False | 34425.0 | 0 |
3416004 | 120888 | None | code22 | Providing and laying plat form using prepolished, water cut / gang saw 40mm thick telephonic Black Granite. laid on existing vertical -supports and fixing in CM 1:3 proportion. Including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including curing. [P - 110/14.52]. | Sqm | 3807.0 | 3807.0 | 2.7 | False | None | None | False | None | False | 10278.9 | 0 |
3416005 | 120888 | None | code23 | Providing full nosing for 40mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification ( P-111/14.53) | Mtr | 583.2 | 583.2 | 15.25 | False | None | None | False | None | False | 8893.8 | 0 |
3416006 | 120888 | None | code24 | Providing half nosing for 40mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification ( P-111/14.54) | Mtr | 388.8 | 388.8 | 15.25 | False | None | None | False | None | False | 5929.2 | 0 |
3416007 | 120888 | None | code25 | Providing and applying two coats of Apex ultima interior paint/ Exterior paint of make and shade as below over one coats of primer/ sealer and two or three coats of putty. The surface should be thoroughly cleaned, dried and ready. Painting and surface preparation should be done as per the manufacturer's specification. Including surface preparation, primer/ sealer, material, cost of labour, cost of equipment and machinery/ fuel, scaffolding, loading and unloading, transportation, all leads and lifts and other incidental charges included etc. complete as directed. (Having VOC (Volatile Organic Compound ) content less than 50 grams/ litre,)Asian Apex paint for external and apcolite premium emulsion for internal surfaces. | Sqm | 125.0 | 125.0 | 133.36 | False | None | None | False | None | False | 16670.0 | 0 |
3416008 | 120888 | None | code26 | KSRB 15-17.6 : Providing and applying painting two coats (excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ( P-121/15.60.1) | Sqm | 104.76 | 104.76 | 3.0 | False | None | None | False | None | False | 314.28 | 0 |
3416009 | 120888 | None | code27 | Providing melamine polishing of approved shade including removing and refixing of doors shutters scraping with blade and rubbing with zero size sand paper and applying sealer coat by way of spraying with necessary compressor and applying patty after rubbing with steel wool including two coats of approved shade of melamine polish etc., complete. ( P-126/15.96) | Sqm | 924.48 | 924.48 | 7.25 | False | None | None | False | None | False | 6702.48 | 0 |
3416010 | 120888 | None | code28 | Providing and applying of non-glossy silicon paint of wacker make or equivalent for the external SMB wall surfaces after cleaning and removing dirt and dust. Application shall be done as per manufacturer specifications. Including surface preparation, material, cost of labour, cost of equipment and machinery/ fuel, scaffolding, loading and unloading, transportation, all leads and lifts and other incidental charges included etc. complete as directed. | Sft | 11.0 | 11.0 | 810.0 | False | None | None | False | None | False | 8910.0 | 0 |
3416011 | 120888 | None | code29 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. Spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.,) 20mm nominal OD pipes | Mtr | 253.8 | 253.8 | 30.0 | False | None | None | False | None | False | 7614.0 | 0 |
3416012 | 120888 | None | code30 | 25mm nominal OD pipes | Mtr | 316.44 | 316.44 | 15.0 | False | None | None | False | None | False | 4746.6 | 0 |
3416013 | 120888 | None | code31 | KSRB13-6.1 : Providing and fixing in position brass bib cock of approved quality nominal bore including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 20mm dia | Nos | 186.84 | 186.84 | 10.0 | False | None | None | False | None | False | 1868.4 | 0 |
3416014 | 120888 | None | code32 | 25mm dia | Nos | 254.88 | 254.88 | 10.0 | False | None | None | False | None | False | 2548.8 | 0 |
3416015 | 120888 | None | code33 | KSRB13-6.2 : Providing and fixing in position brass stop cock of approved quality nominal bore including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 20mm dia | Nos | 152.28 | 152.28 | 3.0 | False | None | None | False | None | False | 456.84 | 0 |
3416016 | 120888 | None | code34 | 25mm dia | Nos | 150.12 | 150.12 | 3.0 | False | None | None | False | None | False | 450.36 | 0 |
3416017 | 120888 | None | code35 | KSRB13-6.4 : Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality nominal bore including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 20mm dia | Nos | 387.72 | 387.72 | 3.0 | False | None | None | False | None | False | 1163.16 | 0 |
3416018 | 120888 | None | code36 | KSRB 13.6.6.1: Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (P. 94/13.46) | Set | 354.0 | 354.0 | 10.0 | False | None | None | False | None | False | 3540.0 | 0 |
3416019 | 120888 | None | code37 | KSRB 13.6.6.3: Providing and fixing unplasticised PVC connection pipe with brass union 20mm nominal bore 300mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (P. 94/13.48) | Set | 261.36 | 261.36 | 10.0 | False | None | None | False | None | False | 2613.6 | 0 |
3416020 | 120888 | None | code38 | KSRB 13.6.7.2: Providing and fixing in position chromium plated brass shower rose with 15 or 20mm inlet 150mm dia including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No. KBS 13.2.16/13.3 (P.95/13.51) | Nos | 810.0 | 810.0 | 3.0 | False | None | None | False | None | False | 2430.0 | 0 |
3416021 | 120888 | None | code39 | KSRB13-7.2 : Providing and fixing in position nominal bore non-return valve vertical type of approved make including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13 25mm dia | Nos | 513.0 | 513.0 | 3.0 | False | None | None | False | None | False | 1539.0 | 0 |
3416022 | 120888 | None | code40 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity) Specification No.KBS 13.22 | Nos | 7374.24 | 7374.24 | 2.0 | False | None | None | False | None | False | 14748.48 | 0 |
3416023 | 120888 | None | code41 | Providing and fixing gun metal wheel valve conforming to IS specification of approved make as per directions including all lead and lift etc., complete.20mm dia | Nos | 447.12 | 447.12 | 2.0 | False | None | None | False | None | False | 894.24 | 0 |
3416024 | 120888 | None | code42 | KSRB13-7.2-1 - do - 25 mm dia nominal bore | Nos | 482.76 | 482.76 | 2.0 | False | None | None | False | None | False | 965.52 | 0 |
3416025 | 120888 | None | code43 | Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and fixing them in position as per directions including of cost of materials and fixtures and conveyance to spot.20mm dia | Nos | 261.36 | 261.36 | 5.0 | False | None | None | False | None | False | 1306.8 | 0 |
3416026 | 120888 | None | code44 | Providing NP/CP waste unions conforming to ISI specifications and fixing them in position as per directions including cost of materials, fixtures and conveyance to work spot etc., complete.32mm dia | Nos | 129.6 | 129.6 | 5.0 | False | None | None | False | None | False | 648.0 | 0 |
3416027 | 120888 | None | code45 | KSRB 12-8.1 : Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS do 455x610mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm | Nos | 7629.12 | 7629.12 | 4.0 | False | None | None | False | None | False | 30516.48 | 0 |
3416028 | 120888 | None | code46 | KSRB 11.1: Providing and fixing white vitreous china clay, water closet Indian type (Suqtting pan) of size 580mm with footrests, 100mm S or P trap, 10 litre low level, P.V.C. flushing cistern (all are approved make) with fittings, C.I/M.S brackets, 32mm diameter flush pipe fittings and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 (P. 79/12.1) | Nos | 3786.48 | 3786.48 | 4.0 | False | None | None | False | None | False | 15145.92 | 0 |
3416029 | 120888 | None | code47 | KSRB 11.5: Providing and fixing white vitreous china clay, water closet European type (Pedestal type, P- trap) with black solid plastic seat and lid, C.P. brass hinges, rubber buffers. 10 litre low level, P.V.C. flushing cistern (all are approved make) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 (P. 79/12.5) | No | 5352.48 | 5352.48 | 1.0 | False | None | None | False | None | False | 5352.48 | 0 |
3416030 | 120888 | None | code48 | KSRB 11.11.5: Providing and fixing white vitreous china clay, flat back wash basin size 500X400mm with a single of 15mm C.P brass pillar taps with C.I/M.S brackets, 32mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wharever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 (P. 83/12.25) | No | 4189.32 | 4189.32 | 5.0 | False | None | None | False | None | False | 20946.6 | 0 |
3416031 | 120888 | None | code49 | KSRB 11.18.7.1: Providing and fixing sand cast iron soil waste single unequal junction of required degree with access door 100X100X75mm, insertion of rubber washers 3mm thick bolts and nuts, including cost of materials, labour, testing complete as per specifications. KBS 11.1.10 (P. 86/12.65) | No | 1164.24 | 1164.24 | 1.0 | False | None | None | False | None | False | 1164.24 | 0 |
3416032 | 120888 | None | code50 | Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. | No | 162.0 | 162.0 | 8.0 | False | None | None | False | None | False | 1296.0 | 0 |
3416033 | 120888 | None | code51 | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 10cmx10cm | No | 205.2 | 205.2 | 5.0 | False | None | None | False | None | False | 1026.0 | 0 |
3416034 | 120888 | None | code52 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot).-do- 10cms x 7.5cms | No | 270.0 | 270.0 | 4.0 | False | None | None | False | None | False | 1080.0 | 0 |
3416035 | 120888 | None | code53 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM and testing complete as per specifications.- do - 110 mm dia | Mtr | 468.72 | 468.72 | 20.0 | False | None | None | False | None | False | 9374.4 | 0 |
3416036 | 120888 | None | code54 | KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, including cost of materials, labour complete as per specifications. | Nos | 1249.56 | 1249.56 | 4.0 | False | None | None | False | None | False | 4998.24 | 0 |
3416037 | 120888 | None | code55 | Removal of debries up to 10.0 km including loading and unloading. | Cum | 143.0 | 143.0 | 35.0 | False | None | None | False | None | False | 5005.0 | 0 |
3416038 | 120888 | None | code56 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary [3/ 1.2] 19/20mm dia 2mm thick Mtr 40.00 [3/ 1.2.1] | Mtr | 40.0 | 40.0 | 120.0 | False | None | None | False | None | False | 4800.0 | 0 |
3416039 | 120888 | None | code57 | 25mm dia 2mm thick Mtr 53.00 [3/ 1.2.2] | Mtr | 53.0 | 53.0 | 60.0 | False | None | None | False | None | False | 3180.0 | 0 |
3416040 | 120888 | None | code58 | Supplying and fixing PVC/metal conduit Deep junction box [3/ 1.5] 19/20mm deep junction box [3/ 1.5.1] | No | 43.0 | 43.0 | 12.0 | False | None | None | False | None | False | 516.0 | 0 |
3416041 | 120888 | None | code59 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. [4/ 1.7]upto 50mm conduit in brick wall [4/ 1.7.1] | Mtr | 21.0 | 21.0 | 60.0 | False | None | None | False | None | False | 1260.0 | 0 |
3416042 | 120888 | None | code60 | Supplying And Fixing Metal Fan Box with Round Hook. [4/ 1.12] | No | 85.0 | 85.0 | 8.0 | False | None | None | False | None | False | 680.0 | 0 |
3416043 | 120888 | None | code61 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( 5/2.2) GROUP A Short point up to 3Mtr from tapping point to out let via switch box (5/2.2.1) | Point | 160.0 | 160.0 | 16.0 | False | None | None | False | None | False | 2560.0 | 0 |
3416044 | 120888 | None | code62 | Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box (5/2.2.2) | Point | 250.0 | 250.0 | 16.0 | False | None | None | False | None | False | 4000.0 | 0 |
3416045 | 120888 | None | code63 | Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box ( 5/2.2.3) | Point | 375.0 | 375.0 | 4.0 | False | None | None | False | None | False | 1500.0 | 0 |
3416046 | 120888 | None | code64 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( 5/2.3) 1.5 sqmm ( 5/2.3.2) | Mtr | 20.5 | 20.5 | 300.0 | False | None | None | False | None | False | 6150.0 | 0 |
3416047 | 120888 | None | code65 | 2.5 sqmm ( 5/2.3.3) | Mtr | 32.0 | 32.0 | 300.0 | False | None | None | False | None | False | 9600.0 | 0 |
3416048 | 120888 | None | code66 | 4 sqmm ( 5/2.3.4) | Mtr | 45.0 | 45.0 | 100.0 | False | None | None | False | None | False | 4500.0 | 0 |
3416049 | 120888 | None | code67 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (9/ 3.3) 1-3Way (9/ 3.3.1) | Each | 85.0 | 85.0 | 4.0 | False | None | None | False | None | False | 340.0 | 0 |
3416050 | 120888 | None | code68 | 4-5Way (9/ 3.3.2) | Each | 103.0 | 103.0 | 4.0 | False | None | None | False | None | False | 412.0 | 0 |
3416051 | 120888 | None | code69 | 6 Way (9/ 3.3.3) | Each | 115.0 | 115.0 | 1.0 | False | None | None | False | None | False | 115.0 | 0 |
3416052 | 120888 | None | code70 | 8 Way (9/ 3.3.4) | Each | 140.0 | 140.0 | 3.0 | False | None | None | False | None | False | 420.0 | 0 |
3416053 | 120888 | None | code71 | 10-12Way (9/ 3.3.5) | Each | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 |
3416054 | 120888 | None | code72 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (9/ 3.4)1-3Way (9/ 3.4.1) | Each | 95.0 | 95.0 | 8.0 | False | None | None | False | None | False | 760.0 | 0 |
3416055 | 120888 | None | code73 | 4-5Way (9/ 3.4.2) | Each | 105.0 | 105.0 | 8.0 | False | None | None | False | None | False | 840.0 | 0 |
3416056 | 120888 | None | code74 | 6 Way (9/ 3.4.3) | Each | 125.0 | 125.0 | 2.0 | False | None | None | False | None | False | 250.0 | 0 |
3416057 | 120888 | None | code75 | 8 Way (9/ 3.4.4) | Each | 145.0 | 145.0 | 6.0 | False | None | None | False | None | False | 870.0 | 0 |
3416058 | 120888 | None | code76 | 10-12 Way (9/ 3.4.5) | Each | 165.0 | 165.0 | 4.0 | False | None | None | False | None | False | 660.0 | 0 |
3416059 | 120888 | None | code77 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. [P 9/ 3.5]1 to 3 Module [P 9/ 3.5.1] | Each | 110.0 | 110.0 | 8.0 | False | None | None | False | None | False | 880.0 | 0 |
3416060 | 120888 | None | code78 | 4 Module [P 9/ 3.5.2] | Each | 125.0 | 125.0 | 8.0 | False | None | None | False | None | False | 1000.0 | 0 |
3416061 | 120888 | None | code79 | 6 Module [P 9/ 3.5.3] | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
3416062 | 120888 | None | code80 | 8 Module [P 9/ 3.5.4] | Each | 200.0 | 200.0 | 6.0 | False | None | None | False | None | False | 1200.0 | 0 |
3416063 | 120888 | None | code81 | 10 -12 Module [P 9/ 3.5.5] | Each | 230.0 | 230.0 | 4.0 | False | None | None | False | None | False | 920.0 | 0 |
3416064 | 120888 | None | code82 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 (16/3.6) 6 Amps one way Switch (16/3.6.1) | Each | 70.0 | 70.0 | 38.0 | False | None | None | False | None | False | 2660.0 | 0 |
3416065 | 120888 | None | code83 | 6 Amps Two way Switch (16/3.6.2) | Each | 95.0 | 95.0 | 8.0 | False | None | None | False | None | False | 760.0 | 0 |
3416066 | 120888 | None | code84 | 6 Amps 3way socket (16/3.6.3) | Each | 105.0 | 105.0 | 10.0 | False | None | None | False | None | False | 1050.0 | 0 |
3416067 | 120888 | None | code85 | Stepped Fan Regulator. (16/3.6.4) | Each | 290.0 | 290.0 | 6.0 | False | None | None | False | None | False | 1740.0 | 0 |
3416068 | 120888 | None | code86 | 32 Amps DP switch (16/3.6.10) | Each | 182.0 | 182.0 | 4.0 | False | None | None | False | None | False | 728.0 | 0 |
3416069 | 120888 | None | code87 | 6/16Amps universal socket (16/3.6.11) | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 |
3416070 | 120888 | None | code88 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. [P 17/ 5.17] 6-32 Amps DP [P 17/ 5.17.6] | Each | 909.0 | 909.0 | 2.0 | False | None | None | False | None | False | 1818.0 | 0 |
3416071 | 120888 | None | code89 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. [P 17/ 5.18]I - Single Door 8 Way SP &N [P 17/ 5.18.3] | Each | 960.0 | 960.0 | 1.0 | False | None | None | False | None | False | 960.0 | 0 |
3416072 | 120888 | None | code90 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. [18/5.20] 16-25 Amps 2 pole [18/5.20.1] | Each | 2300.0 | 2300.0 | 1.0 | False | None | None | False | None | False | 2300.0 | 0 |
3416073 | 120888 | None | code91 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia [19/6.1] | Nos. | 2999.7 | 2999.7 | 2.0 | False | None | None | False | None | False | 5999.4 | 0 |
3416074 | 120888 | None | code92 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 [19/6.4] 4 core 16 sqmm [19/6.4.4] | Mtr | 150.0 | 150.0 | 46.0 | False | None | None | False | None | False | 6900.0 | 0 |
3416075 | 120888 | None | code93 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. [19/6.5] In existing trench/duct. 6 sqmm to 16 sqmm [19/6.5.1] | Mtr | 11.88 | 11.88 | 30.0 | False | None | None | False | None | False | 356.4 | 0 |
3416076 | 120888 | None | code94 | On wall /Structure 6 sqmm to 16 sqmm [19/6.5.6] | Mtr | 30.0 | 30.0 | 16.0 | False | None | None | False | None | False | 480.0 | 0 |
3416077 | 120888 | None | code95 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) [19/6.6] Cutting road surface [19/6.6.3] | Mtr | 82.0 | 82.0 | 20.0 | False | None | None | False | None | False | 1640.0 | 0 |
3416078 | 120888 | None | code96 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. [P 19/ 7.2] 15" Sweep (450mm) [P 19/ 7.2.2] | Each | 4000.0 | 4000.0 | 4.0 | False | None | None | False | None | False | 16000.0 | 0 |
3416079 | 120888 | None | code97 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. [P 19/ 7.3] 48" Sweep (1200mm) Regular model [P 19/ 7.3.1] | Each | 2090.0 | 2090.0 | 6.0 | False | None | None | False | None | False | 12540.0 | 0 |
3416080 | 120888 | None | code98 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. [P 19/ 8.1] 25 Litres [P 19/ 8.1.3] | Each | 8000.0 | 8000.0 | 4.0 | False | None | None | False | None | False | 32000.0 | 0 |
3416081 | 120888 | None | code99 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate materialLESSER delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%LESSER maximum light intensity should be between 60 degrees to 70 degrees. CCT greater 5500KLESSER IP 66 optical and electrical compartment & impact resistance of complete luminaire greater IK08. Power Factor greater 0.9 wiFth mainsLESSER Surge Protection- Min 5KV along with Over voltage/ OverloadLESSER short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598LESSER LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater 130lm/wLESSER nominal CRI greater 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. [P 21/ 12.8] LED Streetlight 70watts [P 21/ 12.8.3] | No | 5480.0 | 5480.0 | 2.0 | False | None | None | False | None | False | 10960.0 | 0 |
3416082 | 120888 | None | code100 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70 PERCENTAGE lumen maintenance with CRI GREATER 80. Power Input: 220-240V @ 50/60Hz & Power factor greater 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. [P 64/ 12.3] LED light fighting 1 x4 inch- 20/22 w [P 64/ 12.3.2] | Each | 375.0 | 375.0 | 12.0 | False | None | None | False | None | False | 4500.0 | 0 |
3416083 | 120888 | None | code101 | Supplying and Fixing of. mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. [P 66/ 14.1] Using 25mm dia G.I.Pipe [P 66/ 14.1.1] | Each | 775.0 | 775.0 | 2.0 | False | None | None | False | None | False | 1550.0 | 0 |
3416084 | 120888 | None | code102 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. [P 66/ 14.5] | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
3416085 | 120888 | None | code103 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. [P 66/ 14.7] On wall / ceiling / Rafter / Girders [P 66/ 14.7.1] | Each | 110.0 | 110.0 | 6.0 | False | None | None | False | None | False | 660.0 | 0 |
3416086 | 120888 | None | code104 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. [P 66/ 14.8] | Each | 150.0 | 150.0 | 6.0 | False | None | None | False | None | False | 900.0 | 0 |
3416087 | 120888 | None | code105 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. [P 66/ 14.12] | Each | 400.0 | 400.0 | 4.0 | False | None | None | False | None | False | 1600.0 | 0 |
3416088 | 120888 | None | code106 | Erection charges for fixing a …litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. [P 67/ 14.13] Up to 30 Litres [P 67/ 14.13.1] | Each | 600.0 | 600.0 | 4.0 | False | None | None | False | None | False | 2400.0 | 0 |