tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719637138000 | 1 | None | None | Buildings | Civil work | 4069866.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3406173 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work.
In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 45.0 | False | None | None | False | None | False | 4488.75 | 0 | 3406174 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 1.15.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 130.8 | False | None | None | False | None | False | 49854.42 | 0 | 3406175 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 13.31 | False | None | None | False | None | False | 79157.232 | 0 | 3406176 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 24.05 | False | None | None | False | None | False | 158762.4675 | 0 | 3406177 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.2.1 | Centering & Shuttering Charges for Footing | Cum | 198.04 | 198.04 | 24.02 | False | None | None | False | None | False | 4756.9208 | 0 | 3406178 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 12.58 | False | None | None | False | None | False | 83520.507 | 0 | 3406179 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.4.2 | Centering & Shuttering charges for columns | Cum | 4647.41 | 4647.41 | 4.81 | False | None | None | False | None | False | 22354.0421 | 0 | 3406180 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.4.2 | Centering & Shuttering charges for plinth beam | Cum | 3319.58 | 3319.58 | 7.77 | False | None | None | False | None | False | 25793.1366 | 0 | 3406181 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 50.6 | False | None | None | False | None | False | 352251.9 | 0 | 3406182 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.5.1 | Centering & Shuttering charges for columns | Cum | 4873.05 | 4873.05 | 6.71 | False | None | None | False | None | False | 32698.1655 | 0 | 3406183 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.5.1 | Centering & Shuttering charges for Lintel & beams | Cum | 4176.9 | 4176.9 | 13.95 | False | None | None | False | None | False | 58267.755 | 0 | 3406184 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.5.2 | Centering & Shuttering charges for roof slab | Cum | 3480.75 | 3480.75 | 29.28 | False | None | None | False | None | False | 101916.36 | 0 | 3406185 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.5.1 | Centering & Shuttering charges for chajja | Cum | 3132.68 | 3132.68 | 0.65 | False | None | None | False | None | False | 2036.242 | 0 | 3406186 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.11(a) | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
a. Buildings | Tonne | 93929.85 | 93929.85 | 7.87 | False | None | None | False | None | False | 739227.9195 | 0 | 3406187 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 5.1.1 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with :
5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 33.26 | False | None | None | False | None | False | 195952.953 | 0 | 3406188 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 30.09 | False | None | None | False | None | False | 201857.2605 | 0 | 3406189 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m. | Cum | 454.65 | 454.65 | 164.85 | False | None | None | False | None | False | 74949.0525 | 0 | 3406190 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 6.8 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 57.0 | False | None | None | False | None | False | 476944.65 | 0 | 3406191 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 1.2 | False | None | None | False | None | False | 124506.9 | 0 | 3406192 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 12.51 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3406193 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 12.52 | Fixing of window frame in an existing opening including embedding frame
in floor and walls after cutting masonry for holdfasts for embedding
holdfast in cement concrete 1:3:6 of 20mm and down size granite metal
painting two coats of coal tar to sides of frame, making good the damages
to walls and floor as required and disposal of the debries with lead
upto 50 m. including cost of materials, labour charges, complete as per
specifications. | No | 811.65 | 811.65 | 12.0 | False | None | None | False | None | False | 9739.8 | 0 | 3406194 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters
for doors with , stiles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 8.4 | False | None | None | False | None | False | 50644.44 | 0 | 3406195 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 12.32 | Providing and fixing in position Mathi / Nandi wood fully panelled shutters
for windows with stiles and rails of 25mm. thick, 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 4060.35 | 4060.35 | 21.6 | False | None | None | False | None | False | 87703.56 | 0 | 3406196 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 453.6 | False | None | None | False | None | False | 87159.24 | 0 | 3406197 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 205.0 | False | None | None | False | None | False | 45417.75 | 0 | 3406198 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 284.16 | False | None | None | False | None | False | 76083.84 | 0 | 3406199 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.51 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge | Sqm | 105.0 | 105.0 | 424.96 | False | None | None | False | None | False | 44620.8 | 0 | 3406200 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 433.41 | False | None | None | False | None | False | 168834.8655 | 0 | 3406201 | 120268 | None | PWD UNI SR 23-24 Vol-1 ITEM No. 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 21.22 | False | None | None | False | None | False | 133440.909 | 0 | 3406202 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 230.04 | False | None | None | False | None | False | 373182.39 | 0 | 3406203 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.21 | Providing White washing with lime to give an even shade :New work (three
coats) with lime of approved quality, including cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 27.3 | 27.3 | 205.0 | False | None | None | False | None | False | 5596.5 | 0 | 3406204 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 284.16 | False | None | None | False | None | False | 40876.416 | 0 | 3406205 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 433.4 | False | None | None | False | None | False | 79182.18 | 0 | 3406206 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge | Sqm | 144.9 | 144.9 | 67.5 | False | None | None | False | None | False | 9780.75 | 0 | 3406207 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 43.2 | False | None | None | False | None | False | 6305.04 | 0 | 3406208 | 120268 | None | item 1 | Providing & fixing green board panelled 1mm thick metal sheet framed with aluminium channel section complete as per IS Standards
as per data rate rs. 8500/no | No | 8500.0 | 8500.0 | 4.0 | False | None | None | False | None | False | 34000.0 | 0 | 3406209 | 120268 | None | PWD UNI SR 23-24 Vol-2 ITEM No. 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
including applying priming coat of approved steel primer. M.S. tube
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 144.9 | 144.9 | 163.8 | False | None | None | False | None | False | 23734.62 | 0 |
| 1719637138000 | 0 | None | None | Buildings | Electrical work | 129183.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3406210 | 120269 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.2.1 | Concealed couduit Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable
size bends, metal/PVC junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using
PVC end enclosures, run with 18SWG GI fish wire wherever
necessary 19/20mm dia 2mm | Rmtr | 66.0 | 66.0 | 120.0 | False | None | None | False | None | False | 7920.0 | 0 | 3406211 | 120269 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.3.1 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering up to the wall surface
and run with 18 SWG GI fish wire run throughout the conduit 19/20mm dia 2mm | Rmtr | 68.0 | 68.0 | 80.0 | False | None | None | False | None | False | 5440.0 | 0 | 3406212 | 120269 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments 2.5 Sqmm | Mtr | 42.0 | 42.0 | 250.0 | False | None | None | False | None | False | 10500.0 | 0 | 3406213 | 120269 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments 4 Sqmm | Mtr | 63.0 | 63.0 | 120.0 | False | None | None | False | None | False | 7560.0 | 0 | 3406214 | 120269 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.4.3 | Supplying and flush mounting powder coated / galvanized
metal box suitable for mounting modular switch plates. The box
should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 4 - 5 way | Rs | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 3406215 | 120269 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.5.3 | Supplying andfixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc.,complete on the
existing metal/PVC box. 4 Module | No | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 3406216 | 120269 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.1 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | No | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 3406217 | 120269 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.3 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket | No | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 3406218 | 120269 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.4 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. Stepped Regulator | No | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 3406219 | 120269 | None | PWD Electrical SR 23-24, P. No. 17 It. No. 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898 6-32Amps SP | No | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 3406220 | 120269 | None | PWD Electrical SR 23-24, P. No. 17 It. No. 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C'
Type curve, indicator ON/OFF, energy cross-3 with Short
circuit breaking capacity of 10K and complete wiring as required
confirming to IEC 60898. 40 Amps TPN | No | 3044.0 | 3044.0 | 2.0 | False | None | None | False | None | False | 6088.0 | 0 | 3406221 | 120269 | None | PWD Electrical SR 23-24, P. No. 28 It. No. 5.19.7 | Supplying and fixing regular MCB distribution boards on wall /
wood board / flush mounting using required clamps, bolts, nuts
etc., with provision for fixing suitable type capacity MCB's
single phase / 3 phase / single door with powder coated
painting. Made out of 14 SWG MS enclosure 6 Way SP & N | No | 1791.0 | 1791.0 | 2.0 | False | None | None | False | None | False | 3582.0 | 0 | 3406222 | 120269 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.41.2 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. flat … with bolts, washers etc., and
painted with 2 coats of red oxide and then two coats of
approved paint. 50x50x6mm | Rmtr | 395.0 | 395.0 | 8.0 | False | None | None | False | None | False | 3160.0 | 0 | 3406223 | 120269 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.42.2 | Fabricating supplying and mounting MS box made out …
SWG suitable for floor / wall mounting, fully weather proof
with provision for better heat dissipation, provided with hinged
front cover, equipped with tamper proof locking arrangements,
with suitable size clamps | Sq CM | 0.43 | 0.43 | 6800.0 | False | None | None | False | None | False | 2924.0 | 0 | 3406224 | 120269 | None | PWD Electrical SR 23-24, P. No. 55 It. No. 12.60. | Supplying & Fixing Chemical earthling for grounding.
Conduits, IC cut-outs& otherequipments backfill compound which is non- corrosive, thermally conductive, potential to
permissible limits, superior Fault conduction capacity,
nontoxic, weathe resistance & capable of achieving ohmic value Earthing | Kit | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | 3406225 | 120269 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.6.2 | Digging of trench of 0.60m deep x 0.50mtrs wide refilling the
trench to the required ground level and consolidating etc.,
complete In hard soil | Mtr | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 | 3406226 | 120269 | None | PWD Electrical SR 23-24, P. No. 40 It. No. 6.4.4 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant
PVC insulated, PVC extruded Inner sheath armoured UG LT
cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip
thickness in average +5% and resistivity 14 Ohms/Kms (Max) as
per IS-3975 4 core 16 Sqmm | Rmtr | 150.0 | 150.0 | 10.0 | False | None | None | False | None | False | 1500.0 | 0 | 3406227 | 120269 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.5.1 | Labour charges for laying of 1.1KV class UG cable when
supplied agency in existing trench GI pipe/stonewere pipe/on
wall/on pole as required exising trench/duct
6 to 16 Sqmm | Mtr | 11.88 | 11.88 | 5.0 | False | None | None | False | None | False | 59.4 | 0 | 3406228 | 120269 | None | PWD Electrical SR 23-24, P. No. 30 It. No. 6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, snackles, canopies etc., for operation on 230 volts, 50
cycles. Single phase AC supply confirming to IS-374-1979 and
with double ball bearing system. 48" sweep (1200mm) regular
model | No | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 | 3406229 | 120269 | None | PWD Electrical SR 23-24, P. No. 57 It. No. 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all
types, with necessary clamps and 'S' hook made out of 15mm
dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted
wire of approved quality, mounted on a suitable size wooden | No | 315.0 | 315.0 | 8.0 | False | None | None | False | None | False | 2520.0 | 0 | 3406230 | 120269 | None | PWD Electrical SR 23-24, P. No. 64 It. No. 11.3.2 | Supplying of .feet - PVC Batten with integrated LED
tube.W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI 80. Power Input:
220-240V @ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition. | No | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 3406231 | 120269 | None | PWD Electrical SR 23-24, P. No. 56 It. No. 13.7 | Fixing all types and all capacities flourescent/false ceiling/spot
light/CFL fittings indoor on the wall/ceiling/rafters/girders
using 23/0.0076" twin twisted PVC insulated wires, required
nos. of round blcks and clamps (if required) on
wall/ceiling/rafters/girders. on wall/ceiling | No | 122.0 | 122.0 | 20.0 | False | None | None | False | None | False | 2440.0 | 0 | 3406232 | 120269 | None | PWD Electrical SR 23-24, P. No. 45 It. No. 118.6 | Supply of LED Streetlight luminaire with pressure die cast
aluminium housing body for optimal thermal dissipation.
Lamp compartment comprising of anti glare clear diffuser
with Injection moulded polycarbonate material, delivering
superior light output. Rated life Burning Hrs 50000 hr @
Lumen Maintenance of 70%, maximum light intensity should be
between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical
and electrical compartment & impact resistance of complete
luminaire IK08. Power Factor 0.9 150 Watts | No | 14705.0 | 14705.0 | 1.0 | False | None | None | False | None | False | 14705.0 | 0 | 3406233 | 120269 | None | PWD Electrical SR 23-24, P. No. 56 It. No. 13.2.3 | Supplying and Fixing.mm dia class A GI pipe bracket
up to 2.7 meters long terminated with a reducing collar of
40x25mm to which extra pipe of 175mm length is fixed for
fixing MV/SV/MH/FTL street light fitting of all capacities on
rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts
and wiring using suitable capacity wires. 40mm dia GI Pipe | No | 1478.0 | 1478.0 | 1.0 | False | None | None | False | None | False | 1478.0 | 0 | 3406234 | 120269 | None | PWD Electrical SR 23-24, P. No. 56 It. No. 13.5 | Fixing Halogen/Metal halide /SVL/IL flood light over existing
pole/wall ceiling including clamps, bolts, nuts and wiring using
suitable capacity wires complete. | No | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 | 3406235 | 120269 | None | item1 | KKRDB LOGO BOARD | Rs | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
|
|
---|