| 1719639568000 | 0 | None | None | Buildings | Construction of Go down in Solid waste Management Site, Construction of Dry waste collection center in different wards and Construction of Dog Shelter for Anti Birth control operation to Street dog in SWM site | 4656489.72 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3406606 | 120298 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir draft, approach channels, key trench, foundation of Buildings & Bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (I. No 1.4.1 P. No-5 of PWD Vol-1 SR 2023-24) | Cum | 249.26 | 249.26 | 117.32 | False | None | None | False | None | False | 29243.1832 | 0 | | 3406607 | 120298 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (I. No 2.1.2, P. No-15 of PWD & IWTD, Vol-1 SR 2023) | Cum | 5833.92 | 5833.92 | 55.62 | False | None | None | False | None | False | 324482.6304 | 0 | | 3406608 | 120298 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.1.1 P. No-9 of PWD & IWTD, Vol-2 SR 2023) | Cum | 5779.33 | 5779.33 | 59.94 | False | None | None | False | None | False | 346413.0402 | 0 | | 3406609 | 120298 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.4 P. No-9 of PWD & IWTD, Vol-2 SR 2023) | Cum | 6580.67 | 6580.67 | 46.99 | False | None | None | False | None | False | 309225.6833 | 0 | | 3406610 | 120298 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.2.1 P. No-15 of PWD Vol-2 SR 2023-24) | Cum | 9713.42 | 9713.42 | 24.32 | False | None | None | False | None | False | 236230.3744 | 0 | | 3406611 | 120298 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (I. No 6.32 P. No-17 of PWD Vol-2 SR 2023-24) | Sqm | 1349.3 | 1349.3 | 244.02 | False | None | None | False | None | False | 329256.186 | 0 | | 3406612 | 120298 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.1.6, P. No-15 of PWD & IWTD, Vol-1 SR 2023) | Cum | 6430.29 | 6430.29 | 47.75 | False | None | None | False | None | False | 307046.3475 | 0 | | 3406613 | 120298 | None | code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.. (Pg No. 18, ItNo. 2.11 h VOL-1 of PWD SR 2023) | Tonne | 81381.33 | 81381.33 | 1.5 | False | None | None | False | None | False | 122071.995 | 0 | | 3406614 | 120298 | None | code09 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge .(I. No 8.1.2, P. No-41 of PWD , Vol-2 SR 2023-24) | Sqm | 248.23 | 248.23 | 511.28 | False | None | None | False | None | False | 126915.0344 | 0 | | 3406615 | 120298 | None | code10 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.2.2, P. No-41 of PWD Vol-2 SR 2023-24) | Sqm | 287.37 | 287.37 | 353.68 | False | None | None | False | None | False | 101637.0216 | 0 | | 3406616 | 120298 | None | code11 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (I. No 11.25.2 , P. No-84 of PWD , Vol-2 SR 2023-24) | Kg | 140.08 | 140.08 | 7875.0 | False | None | None | False | None | False | 1103130.0 | 0 | | 3406617 | 120298 | None | code12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required (I. No 7.38, P. No-26 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 585.04 | 585.04 | 656.6 | False | None | None | False | None | False | 384137.264 | 0 | | 3406618 | 120298 | None | code13 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) . (I. No 7.39.1 , P. No 26 of PWD, Vol-2 SR 2023-24 | Mtr | 464.53 | 464.53 | 10.0 | False | None | None | False | None | False | 4645.3 | 0 | | 3406619 | 120298 | None | code14 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.28 S P. No-45 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 91.67 | 91.67 | 353.68 | False | None | None | False | None | False | 32421.8456 | 0 | | 3406620 | 120298 | None | code15 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (I. No 8.39 P. No-48 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 130.81 | 130.81 | 511.28 | False | None | None | False | None | False | 66880.5368 | 0 | | 3406621 | 120298 | None | code16 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (I. No11.25.1 , P. No-83 of PWD, Vol-2 SR 2023-24) | Kg | 116.39 | 116.39 | 2228.0 | False | None | None | False | None | False | 259316.92 | 0 | | 3406622 | 120298 | None | code17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (I. No11.6.2 , P. No-78 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 2578.0 | 2578.0 | 14.0 | False | None | None | False | None | False | 36092.0 | 0 | | 3406623 | 120298 | None | code18 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2
width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (I. No.8.16.2 , P. No-43 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 39.14 | 39.14 | 51.9 | False | None | None | False | None | False | 2031.366 | 0 | | 3406624 | 120298 | None | code19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (I. No 11.5.1 , P. No 77 of PWD, Vol-2 SR 2023-24 | Sqm | 4612.34 | 4612.34 | 9.45 | False | None | None | False | None | False | 43586.613 | 0 | | 3406625 | 120298 | None | code20 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (I. No 3.1 , P. No-17 of PWD, Vol-2 SR 2023-24) | Cum | 87.55 | 87.55 | 37.8 | False | None | None | False | None | False | 3309.39 | 0 | | 3406626 | 120298 | None | code21 | Wet Mix Macadam (Plant mix method Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Grader in sub- base/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Laying Using Grader (Pg.no:26, I.no:4.17 volume-3 of 2023-24 PWD SR) | Cum | 2635.77 | 2635.77 | 28.35 | False | None | None | False | None | False | 74724.0795 | 0 | | 3406627 | 120298 | None | code22 | Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 ,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) . (P.No.51, I.No.6.6, 2023-24 PWD SR VOL-3) | Cum | 6977.22 | 6977.22 | 28.35 | False | None | None | False | None | False | 197804.187 | 0 | | 3406628 | 120298 | None | code23 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 (P.No.113, I.No.10.1.6, Volume -5 KUWS&DB 2023-24 ) | Mtr | 302.82 | 302.82 | 90.0 | False | None | None | False | None | False | 27253.8 | 0 | | 3406629 | 120298 | None | code24 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6kg/sqcm & class 3 (Item No.10.1.3,Sr Code:M010C, Pg. No.113, PWD , SR 2023-24, Vol-5) | Mtr | 104.03 | 104.03 | 100.0 | False | None | None | False | None | False | 10403.0 | 0 | | 3406630 | 120298 | None | code25 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 25mm dia., 6kg/sqcm & class 3 (Item No.10.1.1, Pg. No.113, PWD , SR 2023-24, Vol-5) | Mtr | 49.44 | 49.44 | 100.0 | False | None | None | False | None | False | 4944.0 | 0 | | 3406631 | 120298 | None | code26 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Item No.13.34,, Pg. No.123, PWD , SR 2023-24, Vol-2) | Mtr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | | 3406632 | 120298 | None | code27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes (Item No.13.31.2,, Pg. No.122, PWD , SR 2023-24, Vol-2) | Mtr | 249.26 | 249.26 | 100.0 | False | None | None | False | None | False | 24926.0 | 0 | | 3406633 | 120298 | None | code28 | Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24 | Cum | 498.52 | 498.52 | 4.5 | False | None | None | False | None | False | 2243.34 | 0 | | 3406634 | 120298 | None | code29 | Refilling available earth around trenches/pipes, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m Including cost of all labour complete as per specifications. (P.No.07, I.No 1.10 in KPWD CSR volume-1, 2023-24 | Cum | 164.8 | 164.8 | 4.5 | False | None | None | False | None | False | 741.6 | 0 | | 3406635 | 120298 | None | code1 | Open Conduit System: Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends,junction boxes,adhesive paste etc,and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (P.No.2, I.No.1.1.1.2023-24 PWD Volume-6 Electrical SR) 19/20 mm dia 2mm thick | Mtr | 71.07 | 71.07 | 60.0 | False | None | None | False | None | False | 4264.2 | 0 | | 3406636 | 120298 | None | code2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall beterminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.05,I.No.2.2.5 of 2023-24 PWD Electrical Volume-6 SR) Three outlet in a row, above 6 mts upto 10 mtr from tapping point to out let via switches box | No | 1018.67 | 1018.67 | 18.0 | False | None | None | False | None | False | 18336.06 | 0 | | 3406637 | 120298 | None | code3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.09 ,I.No.3.6.1, of 2023-24 PWD Electrical Volume-6 SR) | No | 105.06 | 105.06 | 34.0 | False | None | None | False | None | False | 3572.04 | 0 | | 3406638 | 120298 | None | code4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.08, I.No. 3.6.3, of 2023-24 PWD Electrical Volume-6 SR) | No | 176.13 | 176.13 | 2.0 | False | None | None | False | None | False | 352.26 | 0 | | 3406639 | 120298 | None | code5 | Supplying and fixing regular MCB distribution boards on wall/Woodboard/flush mounting using required clamps,bolts,nuts etc.,with provision for fixing suitable type capacity MCB's single phase/3phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (P.No.18,I.No.5.19.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 1278.23 | 1278.23 | 5.0 | False | None | None | False | None | False | 6391.15 | 0 | | 3406640 | 120298 | None | code6 | Supplying of.....feet-PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80.Power Input:220-240V@50/60Hz& Power factor0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.(P.No.43,I.No.11.3.1 & 11.3.2 of 2023-24 PWD Electrical Volume-6 SR) | No | 710.7 | 710.7 | 18.0 | False | None | None | False | None | False | 12792.6 | 0 | | 3406641 | 120298 | None | code7 | Fixing all types and all capacities of fluorescent /falseceiling /spotlight/CFL/LEDfittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. (P.No.56,I.No.13.7.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 125.66 | 125.66 | 18.0 | False | None | None | False | None | False | 2261.88 | 0 | | 3406642 | 120298 | None | code8 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21,I.No.5.46.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 216.3 | 216.3 | 10.0 | False | None | None | False | None | False | 2163.0 | 0 | | 3406643 | 120298 | None | code9 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. (P.No.08,I.No.3.5.6 of 2023-24 PWD Electrical Volume-6 SR) | No | 354.32 | 354.32 | 1.0 | False | None | None | False | None | False | 354.32 | 0 | | 3406644 | 120298 | None | code10 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall,including necessary rawlplugs, Machine/NF screws etc., complete.(P.No.08, I.No. 3.4.6 of 2023-24 PWD Electrical Volume-6 SR) | No | 328.57 | 328.57 | 3.0 | False | None | None | False | None | False | 985.71 | 0 | | 3406645 | 120298 | None | code11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.09 ,I.No.3.6.1, of 2023-24 PWD Electrical Volume-6 SR) | No | 176.13 | 176.13 | 6.0 | False | None | None | False | None | False | 1056.78 | 0 | | 3406646 | 120298 | None | code12 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall,including necessary rawlplugs, Machine/NF screws etc., complete.(P.No.08,I.No. 3.3.4 of 2023-24 PWD Electrical Volume-6 SR) | No | 178.19 | 178.19 | 3.0 | False | None | None | False | None | False | 534.57 | 0 | | 3406647 | 120298 | None | code13 | Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.(P.No.30,I.No.6.2.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 3058.07 | 3058.07 | 3.0 | False | None | None | False | None | False | 9174.21 | 0 | | 3406648 | 120298 | None | code14 | Supply and fixing polished wood board made of not lessthan 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. (P.No.14,I.No.5.6.4 of 2023-24 PWD Electrical Volume-6 SR) | No | 186.43 | 186.43 | 1.0 | False | None | None | False | None | False | 186.43 | 0 | | 3406649 | 120298 | None | code15 | Supplying & fixing of Porcelain fuse channel with cutout on existing wooden/panel using necessary nuts, bolts and washers. (P.No.14,I.No.5.7.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 161.71 | 161.71 | 1.0 | False | None | None | False | None | False | 161.71 | 0 | | 3406650 | 120298 | None | code16 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5to20A single phase Class-1 Accuracy with Temper Proof EnergyMeter.(P.No.19,I.No.5.30 of 2023-24 PWD Electrical Volume-6 SR) | No | 1421.4 | 1421.4 | 3.0 | False | None | None | False | None | False | 4264.2 | 0 | | 3406651 | 120298 | None | code17 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. (P.No.21,I.No.5.46.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 216.3 | 216.3 | 3.0 | False | None | None | False | None | False | 648.9 | 0 | | 3406652 | 120298 | None | code18 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box. (P.No.08,I.No.3.5.4 of 2023-24 PWD Electrical Volume-6 SR) | No | 241.02 | 241.02 | 3.0 | False | None | None | False | None | False | 723.06 | 0 | | 3406653 | 120298 | None | code19 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.(P.No.52,I.No.21.05 of 2023-24 PWD Electrical Volume-6 SR) | Km | 21512.58 | 21512.58 | 0.03 | False | None | None | False | None | False | 645.3774 | 0 | | 3406654 | 120298 | None | code20 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. (P.No.13,I.No.32.03 of 2023-24 PWD Electrical Volume-6 SR) | Km | 121544.12 | 121544.12 | 0.03 | False | None | None | False | None | False | 3646.3236 | 0 | | 3406655 | 120298 | None | code21 | Fabricating,supplying and erection of...ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft,IS2062 for base plate with door opening arrangements,including suitable boards,Bakelite sheet and MCB as per IS specifications suitable to with stand the wind speed of 47m/s for.......m Pole in single section and single joint welded as per IS9595/IS10178AW Shaving dimensions bottom.....mm,top....mm with 3mm thick,suitable base plate and 4 Nos of.....long J bolts along with template and the Pole shall be hotdip galvanized in single dipping with not lessthan 65 micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended.(P.No.11,I.No.4.2.2 of 2023-24 PWD Electrical Volume-6 SR) | No | 8446.0 | 8446.0 | 4.0 | False | None | None | False | None | False | 33784.0 | 0 | | 3406656 | 120298 | None | code22 | Supply of LED Street light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material,delivering superior light output Rated life Burning Hrs 50000hr@Lumen Maintenance of 70%,maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500 K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection-Min5KValongwithOvervoltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS10322/IEC60598, LM79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/Embossing on the diecast housing/Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source..(P.No.45,I.No.11.8.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 2497.75 | 2497.75 | 8.0 | False | None | None | False | None | False | 19982.0 | 0 | | 3406657 | 120298 | None | code23 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket Street light fitting of all capacities to GI or GI or rail or RCC pole/wall using suitable clamps,bolts,and nuts and wiring using suitable capacity wires.(P.No.56,I.No.13.1.1 of 2023-24 PWD Electrical Volume-6 SR) | No | 1007.34 | 1007.34 | 8.0 | False | None | None | False | None | False | 8058.72 | 0 | | 3406658 | 120298 | None | code24 | Fixing halogen/metalhalide/SVL/IL/LED floodlight fitting over existing pole/wallceilingin cluding clamps,bolts,nutsandwiringusing suitable capacity wires.(P.No.56,I.No.13.5 of 2023-24 PWD Electrical Volume-6 SR) | No | 166.86 | 166.86 | 8.0 | False | None | None | False | None | False | 1334.88 | 0 | | 3406659 | 120298 | None | code25 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21,I.No.5.46.1 of 2023-24 PWD Electrical Volume-6 SR) 16 - 32 A SP | No | 216.3 | 216.3 | 2.0 | False | None | None | False | None | False | 432.6 | 0 |
|