3397683 | 119794 | None | item001 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials to the appropriate disposal area stacking serviceable and unserviceable material separately including cutting reinforcement bars as per specifications and as per directions of Engineer in charge. | Cum | 3049.0 | 3049.0 | 117.22 | False | None | None | False | None | False | 357403.78 | 0 |
3397684 | 119794 | None | item002 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in charge. | Cum | 625.64 | 625.64 | 157.34 | False | None | None | False | None | False | 98438.1976 | 0 |
3397685 | 119794 | None | item003 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer in charge of area beyond 3 m² as per specifications and as per directions of Engineer in charge. | Sqm | 340.08 | 340.08 | 96.95 | False | None | None | False | None | False | 32970.756 | 0 |
3397686 | 119794 | None | item004 | Dismantling steel work in single sections including dismembering and stacking within to the appropriate disposal area as per direction of Engineer in charge.Channels, angles, tees and flats as per specifications and as per directions of Engineer in charge. | Kg | 1.3 | 1.3 | 336.0 | False | None | None | False | None | False | 436.8 | 0 |
3397687 | 119794 | None | item005 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin charge.In cement mortar as per specifications and as per directions of Engineer in charge. | Cum | 2185.83 | 2185.83 | 16.65 | False | None | None | False | None | False | 36394.0695 | 0 |
3397688 | 119794 | None | item006 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m as per specification and as per directions of Engineer in charge. | Cum | 719.09 | 719.09 | 1032.1 | False | None | None | False | None | False | 742172.789 | 0 |
3397689 | 119794 | None | item007 | Providing and injecting chemical emulsion for Pre constructional Anti Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications and as per directions of Engineer in charge. | Sqm | 153.16 | 153.16 | 813.1 | False | None | None | False | None | False | 124534.396 | 0 |
3397690 | 119794 | None | item008 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 7773.72 | 7773.72 | 215.14 | False | None | None | False | None | False | 1672438.1208 | 0 |
3397691 | 119794 | None | item009 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications and as per directions of Engineer in charge..(Soling work) | Cum | 3481.24 | 3481.24 | 215.14 | False | None | None | False | None | False | 748953.9736 | 0 |
3397692 | 119794 | None | item010 | Ready Mix Concrete (RMC) with Cement & Cementitious Materials.Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75% & GGBS at 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer in charge. RMC M25 Grade | Cum | 8072.26 | 8072.26 | 12.51 | False | None | None | False | None | False | 100983.9726 | 0 |
3397693 | 119794 | None | item011 | Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m as per specifications and as per directions of Engineer in charge. | Cum | 345.27 | 345.27 | 589.14 | False | None | None | False | None | False | 203412.3678 | 0 |
3397694 | 119794 | None | item012 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m as per specifications and as per directions of Engineer in charge. | Cum | 562.03 | 562.03 | 378.96 | False | None | None | False | None | False | 212986.8888 | 0 |
3397695 | 119794 | None | item013 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 8635.33 | 8635.33 | 219.79 | False | None | None | False | None | False | 1897959.1807 | 0 |
3397696 | 119794 | None | item014 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) as per specifications and as per directions of Engineer in charge. | Cum | 8292.92 | 8292.92 | 82.62 | False | None | None | False | None | False | 685161.0504 | 0 |
3397697 | 119794 | None | item015 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 12336.19 | 12336.19 | 52.54 | False | None | None | False | None | False | 648143.4226 | 0 |
3397698 | 119794 | None | item016 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 15099.76 | 15099.76 | 22.49 | False | None | None | False | None | False | 339593.6024 | 0 |
3397699 | 119794 | None | item017 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 9252.14 | 9252.14 | 9.4 | False | None | None | False | None | False | 86970.116 | 0 |
3397700 | 119794 | None | item018 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 8605.74 | 8605.74 | 93.13 | False | None | None | False | None | False | 801452.5662 | 0 |
3397701 | 119794 | None | item019 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 13323.32 | 13323.32 | 126.4 | False | None | None | False | None | False | 1684067.648 | 0 |
3397702 | 119794 | None | item020 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 14211.54 | 14211.54 | 81.21 | False | None | None | False | None | False | 1154119.1634 | 0 |
3397703 | 119794 | None | item021 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings as per specifications and as per directions of Engineer in charge. | t | 116115.19 | 116115.19 | 57.2 | False | None | None | False | None | False | 6641788.868 | 0 |
3397704 | 119794 | None | item022 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications and as per directions of Engineer in charge. | Sqm | 1700.38 | 1700.38 | 593.4 | False | None | None | False | None | False | 1009005.492 | 0 |
3397705 | 119794 | None | item023 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications and as per directions of Engineer in charge. | Sqm | 1432.99 | 1432.99 | 186.96 | False | None | None | False | None | False | 267911.8104 | 0 |
3397706 | 119794 | None | item024 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 12879.21 | 12879.21 | 2.19 | False | None | None | False | None | False | 28205.4699 | 0 |
3397707 | 119794 | None | item025 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 404.98 | 404.98 | 732.66 | False | None | None | False | None | False | 296712.6468 | 0 |
3397708 | 119794 | None | item026 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 453.0 | 453.0 | 1546.45 | False | None | None | False | None | False | 700541.85 | 0 |
3397709 | 119794 | None | item027 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 556.84 | 556.84 | 391.3 | False | None | None | False | None | False | 217891.492 | 0 |
3397710 | 119794 | None | item028 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 129.8 | 129.8 | 2279.11 | False | None | None | False | None | False | 295828.478 | 0 |
3397711 | 119794 | None | item029 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 142.78 | 142.78 | 2279.11 | False | None | None | False | None | False | 325411.3258 | 0 |
3397712 | 119794 | None | item030 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 225.85 | 225.85 | 391.3 | False | None | None | False | None | False | 88375.105 | 0 |
3397713 | 119794 | None | item031 | Toughened glass 12 mm thickness with hole as per specifications and as per directions of Engineer in charge. | Sqm | 2100.0 | 2100.0 | 16.15 | False | None | None | False | None | False | 33915.0 | 0 |
3397714 | 119794 | None | item032 | Providing and fixing Double shutter glass door of 12mm thick frosted toughened glass of approved make. The door is fixed by using any approved make hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable SS door rails with floral glass etching for 1/3 portion of door area etc complete. The rate includes cost of all materials, labour, hire of tools & machineries, as per specifications etc complete. The rate includes cost of all materials, labour, hire of tools & machineries,as per specifications and as per directions of Engineer in charge. | Sqm | 11043.38 | 11043.38 | 29.51 | False | None | None | False | None | False | 325890.1438 | 0 |
3397715 | 119794 | None | item033 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM completeas per specifications and as per directions of Engineer in charge. | Cum | 128261.87 | 128261.87 | 3.39 | False | None | None | False | None | False | 434807.7393 | 0 |
3397716 | 119794 | None | item034 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part I) 1991. from manufacturer complete as per spcification. do 30 mm thick both side Teak as per specifications and as per directions of Engineer in charge. | Sqm | 5247.81 | 5247.81 | 42.17 | False | None | None | False | None | False | 221300.1477 | 0 |
3397717 | 119794 | None | item035 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer in charge. | Sqm | 412.76 | 412.76 | 17.1 | False | None | None | False | None | False | 7058.196 | 0 |
3397718 | 119794 | None | item036 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges. do with one side prelam as per specifications and as per directions of Engineer in charge. | Sqm | 2647.92 | 2647.92 | 4.73 | False | None | None | False | None | False | 12524.6616 | 0 |
3397719 | 119794 | None | item037 | Providing & fixing of 3track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 30mm x 48.5mm. Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2119mm as per specifications and as per directions of Engineer in charge. | Sqm | 8740.73 | 8740.73 | 50.85 | False | None | None | False | None | False | 444466.1205 | 0 |
3397720 | 119794 | None | item038 | Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM completeas per specifications and as per directions of Engineer in charge. | Kgs | 218.06 | 218.06 | 1067.85 | False | None | None | False | None | False | 232855.371 | 0 |
3397721 | 119794 | None | item039 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge | Sqm | 10742.25 | 10742.25 | 17.76 | False | None | None | False | None | False | 190782.36 | 0 |
3397722 | 119794 | None | item040 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer in Charge.** Polished Granite stone slab Black,Cat Eye, River Pink or equivalent. | Sqm | 3701.9 | 3701.9 | 162.0 | False | None | None | False | None | False | 599707.8 | 0 |
3397723 | 119794 | None | item041 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and as per directions of Engineer in charge. | Sqm | 1880.8 | 1880.8 | 600.2 | False | None | None | False | None | False | 1128856.16 | 0 |
3397724 | 119794 | None | item042 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. as per specifications and as per directions of Engineer in charge. | Sqm | 4359.98 | 4359.98 | 157.91 | False | None | None | False | None | False | 688484.4418 | 0 |
3397725 | 119794 | None | item043 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1000x1000 mm as per specifications and as per directions of Engineer in charge. | Sqm | 2419.47 | 2419.47 | 340.92 | False | None | None | False | None | False | 824845.7124 | 0 |
3397726 | 119794 | None | item044 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete as per specifications and as per directions of Engineer in charge. | Sqm | 1435.59 | 1435.59 | 52.52 | False | None | None | False | None | False | 75397.1868 | 0 |
3397727 | 119794 | None | item045 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. as per specifications and as per directions of Engineer in charge. | Sqm | 1435.59 | 1435.59 | 165.19 | False | None | None | False | None | False | 237145.1121 | 0 |
3397728 | 119794 | None | item046 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed,including cost of materials, mortar, labour, curing complete as per specifications as per specifications and as per directions of Engineer in charge. | Sqm | 6915.74 | 6915.74 | 101.7 | False | None | None | False | None | False | 703330.758 | 0 |
3397729 | 119794 | None | item047 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in charge | Mtr | 425.74 | 425.74 | 166.8 | False | None | None | False | None | False | 71013.432 | 0 |
3397730 | 119794 | None | item048 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specifications and as per directions of Engineer in charge. | Sqm | 1060.47 | 1060.47 | 52.52 | False | None | None | False | None | False | 55695.8844 | 0 |
3397731 | 119794 | None | item049 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge. | Kgs | 733.37 | 733.37 | 157.2 | False | None | None | False | None | False | 115285.764 | 0 |
3397732 | 119794 | None | item050 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part III). The Suspended System held with Spider Fittings of SS 316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.as per specifications and as per directions of Engineer in charge. | Sqm | 10321.7 | 10321.7 | 36.8 | False | None | None | False | None | False | 379838.56 | 0 |
3397733 | 119794 | None | item051 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119 12 and clause B, S1, do as per ENT 13501 1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion as per specifications and as per directions of Engineer in charge. | Sqm | 5177.72 | 5177.72 | 131.35 | False | None | None | False | None | False | 680093.522 | 0 |
3397734 | 119794 | None | item052 | a)Providing and fixing of Door locking arrangements as per specifications and as per directions of Engineer in charge. | Each | 348.0 | 348.0 | 40.0 | False | None | None | False | None | False | 13920.0 | 0 |
3397735 | 119794 | None | item053 | b)Providing and fixing of Handles powder coated 150mm as per specifications and as per directions of Engineer in charge | Each | 60.0 | 60.0 | 120.0 | False | None | None | False | None | False | 7200.0 | 0 |
3397736 | 119794 | None | item054 | c)Providing and fixing of Hinges 5" heavy duty as per specifications and as per directions of Engineer in charge. | Each | 38.0 | 38.0 | 120.0 | False | None | None | False | None | False | 4560.0 | 0 |
3397737 | 119794 | None | item055 | d)Providing and fixing of Hold fasts MS as per specifications and as per directions of Engineer in charge. | Each | 50.0 | 50.0 | 160.0 | False | None | None | False | None | False | 8000.0 | 0 |
3397738 | 119794 | None | item056 | e)Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 250x10mm as per specifications and as per directions of Engineer in charge. | Nos | 200.0 | 200.0 | 80.0 | False | None | None | False | None | False | 16000.0 | 0 |
3397739 | 119794 | None | item057 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. as per specifications and as per directions of Engineer in charge. | Cum | 15250.76 | 15250.76 | 13.21 | False | None | None | False | None | False | 201462.5396 | 0 |
3397740 | 119794 | None | item058 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 9344.67 | 9344.67 | 9.4 | False | None | None | False | None | False | 87839.898 | 0 |
3397741 | 119794 | None | item059 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. as per specifications and as per directions of Engineer in charge. | Cum | 13456.55 | 13456.55 | 100.21 | False | None | None | False | None | False | 1348480.8755 | 0 |
3397742 | 119794 | None | item060 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 14353.66 | 14353.66 | 61.55 | False | None | None | False | None | False | 883467.773 | 0 |
3397743 | 119794 | None | item061 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings as per specifications and as per directions of Engineer in charge. | t | 117276.34 | 117276.34 | 21.86 | False | None | None | False | None | False | 2563660.7924 | 0 |
3397744 | 119794 | None | item062 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications and as per directions of Engineer in charge. | Sqm | 1717.38 | 1717.38 | 484.12 | False | None | None | False | None | False | 831418.0056 | 0 |
3397745 | 119794 | None | item063 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications and as per directions of Engineer in charge. | Sqm | 1447.32 | 1447.32 | 39.29 | False | None | None | False | None | False | 56865.2028 | 0 |
3397746 | 119794 | None | item064 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications and as per directions of Engineer in charge. | Cum | 13008.0 | 13008.0 | 2.01 | False | None | None | False | None | False | 26146.08 | 0 |
3397747 | 119794 | None | item065 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 409.03 | 409.03 | 636.75 | False | None | None | False | None | False | 260449.8525 | 0 |
3397748 | 119794 | None | item066 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 457.53 | 457.53 | 1069.31 | False | None | None | False | None | False | 489241.4043 | 0 |
3397749 | 119794 | None | item067 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 562.41 | 562.41 | 391.3 | False | None | None | False | None | False | 220071.033 | 0 |
3397750 | 119794 | None | item068 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 131.1 | 131.1 | 1706.06 | False | None | None | False | None | False | 223664.466 | 0 |
3397751 | 119794 | None | item069 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 144.21 | 144.21 | 1706.06 | False | None | None | False | None | False | 246030.9126 | 0 |
3397752 | 119794 | None | item070 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge | Sqm | 228.11 | 228.11 | 391.3 | False | None | None | False | None | False | 89259.443 | 0 |
3397753 | 119794 | None | item071 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM complete as per specifications and as per directions of Engineer in charge. | Cum | 129544.49 | 129544.49 | 1.58 | False | None | None | False | None | False | 204680.2942 | 0 |
3397754 | 119794 | None | item072 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part I) 1991. from manufacturer complete as per spcification. do 30 mm thick both side Teak as per specifications and as per directions of Engineer in charge. | Sqm | 5300.29 | 5300.29 | 22.95 | False | None | None | False | None | False | 121641.6555 | 0 |
3397755 | 119794 | None | item073 | Providing & fixing of 3track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame havinga overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 30mm x 48.5mm. Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2119mm as per specifications and as per directions of Engineer in charge. | Sqm | 8828.14 | 8828.14 | 49.47 | False | None | None | False | None | False | 436728.0858 | 0 |
3397756 | 119794 | None | item074 | Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM complete as per specifications and as per directions of Engineer in charge. | Kgs | 220.24 | 220.24 | 1038.87 | False | None | None | False | None | False | 228800.7288 | 0 |
3397757 | 119794 | None | item075 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1000x1000 mm as per specifications and as per directions of Engineer in charge. | Sqm | 2443.67 | 2443.67 | 464.35 | False | None | None | False | None | False | 1134718.1645 | 0 |
3397758 | 119794 | None | item076 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and as per directions of Engineer in charge. | Sqm | 1899.61 | 1899.61 | 479.23 | False | None | None | False | None | False | 910350.1003 | 0 |
3397759 | 119794 | None | item077 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer in Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent as per specifications and as per directions of Engineer in charge. | Sqm | 3738.91 | 3738.91 | 119.86 | False | None | None | False | None | False | 448145.7526 | 0 |
3397760 | 119794 | None | item078 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.as per specifications and as per directions of Engineer in charge. | Sqm | 4403.58 | 4403.58 | 81.27 | False | None | None | False | None | False | 357878.9466 | 0 |
3397761 | 119794 | None | item079 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete as per specifications and as per directions of Engineer in charge. | Sqm | 1449.94 | 1449.94 | 32.63 | False | None | None | False | None | False | 47311.5422 | 0 |
3397762 | 119794 | None | item080 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. as per specifications and as per directions of Engineer in charge. | Sqm | 1449.94 | 1449.94 | 98.66 | False | None | None | False | None | False | 143051.0804 | 0 |
3397763 | 119794 | None | item081 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed,including cost of materials, mortar, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 6984.9 | 6984.9 | 47.55 | False | None | None | False | None | False | 332131.995 | 0 |
3397764 | 119794 | None | item082 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in charge | Mtr | 430.0 | 430.0 | 88.5 | False | None | None | False | None | False | 38055.0 | 0 |
3397765 | 119794 | None | item083 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specifications and as per directions of Engineer in charge. | Sqm | 1071.07 | 1071.07 | 32.63 | False | None | None | False | None | False | 34949.0141 | 0 |
3397766 | 119794 | None | item084 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge. | Kgs | 740.7 | 740.7 | 50.4 | False | None | None | False | None | False | 37331.28 | 0 |
3397767 | 119794 | None | item085 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part III). The Suspended System held with Spider Fittings of SS 316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. as per specifications and as per directions of Engineer in charge. | Sqm | 10424.91 | 10424.91 | 51.3 | False | None | None | False | None | False | 534797.883 | 0 |
3397768 | 119794 | None | item086 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119 12 and clause B, S1, do as per ENT 13501 1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion as per specifications and as per directions of Engineer in charge. | Sqm | 5229.5 | 5229.5 | 136.55 | False | None | None | False | None | False | 714088.225 | 0 |
3397769 | 119794 | None | item087 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work a)25mm dia as per specifications and as per directions of Engineer in charge. | m | 384.21 | 384.21 | 100.0 | False | None | None | False | None | False | 38421.0 | 0 |
3397770 | 119794 | None | item088 | b)32mm dia as per specifications and as per directions of Engineer in charge. | m | 482.86 | 482.86 | 110.0 | False | None | None | False | None | False | 53114.6 | 0 |
3397771 | 119794 | None | item089 | c)40mm dia as per specifications and as per directions of Engineer in charge. | m | 619.15 | 619.15 | 115.0 | False | None | None | False | None | False | 71202.25 | 0 |
3397772 | 119794 | None | item090 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. as per specifications and as per directions of Engineer in charge. a)15mm dia as per specifications and as per directions of Engineer in charge. | m | 401.08 | 401.08 | 100.0 | False | None | None | False | None | False | 40108.0 | 0 |
3397773 | 119794 | None | item091 | b)20mm dia as per specifications and as per directions of Engineer in charge. | m | 491.94 | 491.94 | 110.0 | False | None | None | False | None | False | 54113.4 | 0 |
3397774 | 119794 | None | item092 | c)25mm dia as per specifications and as per directions of Engineer in charge. | m | 619.15 | 619.15 | 115.0 | False | None | None | False | None | False | 71202.25 | 0 |
3397775 | 119794 | None | item093 | Providing and fixing water meter with stop cock, jam nut, socket in G.I pipe line including cutting and threading the pipe and making long screws including cost of all materials, labour , HOM of equipments and testing complete as per specifications and as per directions of Engineer in charge. | Set | 1713.36 | 1713.36 | 1.0 | False | None | None | False | None | False | 1713.36 | 0 |
3397776 | 119794 | None | item094 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :a)25mm dia as per specifications and as per directions of Engineer in charge. | Nos | 430.94 | 430.94 | 28.0 | False | None | None | False | None | False | 12066.32 | 0 |
3397777 | 119794 | None | item095 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : a)32 mm dia as per specifications and as per directions of Engineer in charge. | Nos | 776.2 | 776.2 | 18.0 | False | None | None | False | None | False | 13971.6 | 0 |
3397778 | 119794 | None | item096 | b)40mm dia as per specifications and as per directions of Engineer in charge. | Nos | 911.2 | 911.2 | 25.0 | False | None | None | False | None | False | 22780.0 | 0 |
3397779 | 119794 | None | item097 | Providing and fixing gun metal non return valve of approved quality (screwedend): 40 mm nominal bore ,Vertical as per specifications and as per directions of Engineer in charge. | Each | 1590.05 | 1590.05 | 20.0 | False | None | None | False | None | False | 31801.0 | 0 |
3397780 | 119794 | None | item098 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for::a.PVC pipes 75mm dia., 6 kg/sqcm & class 3 b.PVC pipes 110mm dia., 6 kg/sqcm & class 3. BWSSB SR 2023 2024 as per specifications and as per directions of Engineer in charge. a)75mm dia as per specifications and as per directions of Engineer in charge. | Mtr | 285.56 | 285.56 | 120.0 | False | None | None | False | None | False | 34267.2 | 0 |
3397781 | 119794 | None | item099 | b)110mm dia as per specifications and as per directions of Engineer in charge. | Mtr | 533.48 | 533.48 | 135.0 | False | None | None | False | None | False | 72019.8 | 0 |
3397782 | 119794 | None | item100 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :*100 mm inlet and 100 mm outlet* Sand Cast Iron S&S as per IS:3989 as per specifications and as per directions of Engineer in charge. | Each | 1806.82 | 1806.82 | 15.0 | False | None | None | False | None | False | 27102.3 | 0 |
3397783 | 119794 | None | item101 | Providing and fixing PTMT grating of approved quality and colour. A)125mm dia as per specifications and as per directions of Engineer in charge. | Nos | 57.11 | 57.11 | 10.0 | False | None | None | False | None | False | 571.1 | 0 |
3397784 | 119794 | None | item102 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer in charge. | Each | 101.24 | 101.24 | 15.0 | False | None | None | False | None | False | 1518.6 | 0 |
3397785 | 119794 | None | item103 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.BWSSB 2023 24 as per specifications and as per directions of Engineer in charge. | Nos | 6218.72 | 6218.72 | 8.0 | False | None | None | False | None | False | 49749.76 | 0 |
3397786 | 119794 | None | item104 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe 500) with 3mm thick plastic encapsulation (IS 10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame. BWSSB 2023 24 as per specifications and as per directions of Engineer in charge. | Nos | 37703.01 | 37703.01 | 2.0 | False | None | None | False | None | False | 75406.02 | 0 |
3397787 | 119794 | None | item105 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick as per specifications and as per directions of Engineer in charge. | m | 95.58 | 95.58 | 50.0 | False | None | None | False | None | False | 4779.0 | 0 |
3397788 | 119794 | None | item106 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick as per specifications and as per directions of Engineer in charge. | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 |
3397789 | 119794 | None | item107 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick as per specifications and as per directions of Engineer in charge. | m | 92.04 | 92.04 | 1550.0 | False | None | None | False | None | False | 142662.0 | 0 |
3397790 | 119794 | None | item108 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thick as per specifications and as per directions of Engineer in charge. | m | 121.54 | 121.54 | 200.0 | False | None | None | False | None | False | 24308.0 | 0 |
3397791 | 119794 | None | item109 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick as per specifications and as per directions of Engineer in charge. | m | 80.24 | 80.24 | 750.0 | False | None | None | False | None | False | 60180.0 | 0 |
3397792 | 119794 | None | item110 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick as per specifications and as per directions of Engineer in charge. | m | 93.22 | 93.22 | 850.0 | False | None | None | False | None | False | 79237.0 | 0 |
3397793 | 119794 | None | item111 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick as per specifications and as per directions of Engineer in charge. | m | 116.82 | 116.82 | 50.0 | False | None | None | False | None | False | 5841.0 | 0 |
3397794 | 119794 | None | item112 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm as per specifications and as per directions of Engineer in charge. | m | 41.3 | 41.3 | 50.0 | False | None | None | False | None | False | 2065.0 | 0 |
3397795 | 119794 | None | item113 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm as per specifications and as per directions of Engineer in charge. | m | 25.96 | 25.96 | 25.0 | False | None | None | False | None | False | 649.0 | 0 |
3397796 | 119794 | None | item114 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mm as per specifications and as per directions of Engineer in charge. | m | 34.22 | 34.22 | 30.0 | False | None | None | False | None | False | 1026.6 | 0 |
3397797 | 119794 | None | item115 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required w ith one coat of primer of approved make etc. 180 x 90 x 65 mm as per specifications and as per directions of Engineer in charge. | No | 189.98 | 189.98 | 5.0 | False | None | None | False | None | False | 949.9 | 0 |
3397798 | 119794 | None | item116 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box as per specifications and as per directions of Engineer in charge. | Point | 317.42 | 317.42 | 52.0 | False | None | None | False | None | False | 16505.84 | 0 |
3397799 | 119794 | None | item117 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box as per specifications and as per directions of Engineer in charge. | Point | 447.22 | 447.22 | 81.0 | False | None | None | False | None | False | 36224.82 | 0 |
3397800 | 119794 | None | item118 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box as per specifications and as per directions of Engineer in charge. | Point | 654.9 | 654.9 | 156.0 | False | None | None | False | None | False | 102164.4 | 0 |
3397801 | 119794 | None | item119 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switches as per specifications and as per directions of Engineer in charge. | Point | 798.86 | 798.86 | 11.0 | False | None | None | False | None | False | 8787.46 | 0 |
3397802 | 119794 | None | item120 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box as per specifications and as per directions of Engineer in charge. | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 |
3397803 | 119794 | None | item121 | Heavy Duty Copper Terminal Long Barrel
35 Sqmm Copper Terminal, Apprx Wt: 17 Gm as per specifications and as per directions of Engineer in charge. | Each | 47.2 | 47.2 | 32.0 | False | None | None | False | None | False | 1510.4 | 0 |
3397804 | 119794 | None | item122 | Supplying tinned copper lugs and crimping and wiring to
terminal point for wire of the following sizes. 6 sqmm as per specifications and as per directions of Engineer in charge. | Each | 8.26 | 8.26 | 8.0 | False | None | None | False | None | False | 66.08 | 0 |
3397805 | 119794 | None | item123 | Heavy Duty Copper Terminal Long Barrel
50 Sqmm Copper Terminal, Apprx Wt: 26 Gm as per specifications and as per directions of Engineer in charge. | No | 68.44 | 68.44 | 2.0 | False | None | None | False | None | False | 136.88 | 0 |
3397806 | 119794 | None | item124 | Heavy Duty Copper Terminal Long Barrel
120 Sqmm Copper Terminal, Apprx Wt: 64 Gm as per specifications and as per directions of Engineer in charge. | No | 165.2 | 165.2 | 6.0 | False | None | None | False | None | False | 991.2 | 0 |
3397807 | 119794 | None | item125 | Supplying and fixing of heavy duty cable glands suitable for
UG cable of 1.1 KV class (metal only) 19/20 as per specifications and as per directions of Engineer in charge. | No | 80.24 | 80.24 | 2.0 | False | None | None | False | None | False | 160.48 | 0 |
3397808 | 119794 | None | item126 | Brass Cable Gland 32 as per specifications and as per directions of Engineer in charge. | No | 112.1 | 112.1 | 2.0 | False | None | None | False | None | False | 224.2 | 0 |
3397809 | 119794 | None | item127 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT as per specifications and as per directions of Engineer in charge. | Each | 2009.54 | 2009.54 | 1.0 | False | None | None | False | None | False | 2009.54 | 0 |
3397810 | 119794 | None | item128 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A SP as per specifications and as per directions of Engineer in charge. | Each | 489.7 | 489.7 | 4.0 | False | None | None | False | None | False | 1958.8 | 0 |
3397811 | 119794 | None | item129 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy as per specifications and as per directions of Engineer in charge. | Each | 10991.7 | 10991.7 | 1.0 | False | None | None | False | None | False | 10991.7 | 0 |
3397812 | 119794 | None | item130 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947 2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 200 A 25 kA as per specifications and as per directions of Engineer in charge. | Each | 20415.18 | 20415.18 | 1.0 | False | None | None | False | None | False | 20415.18 | 0 |
3397813 | 119794 | None | item131 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips as per specifications and as per directions of Engineer in charge. | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 |
3397814 | 119794 | None | item132 | Rotary handle for MCCB as per specifications and as per directions of Engineer in charge. | Each | 4422.64 | 4422.64 | 1.0 | False | None | None | False | None | False | 4422.64 | 0 |
3397815 | 119794 | None | item133 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50 63 A TPN as per specifications and as per directions of Engineer in charge. | Each | 3643.84 | 3643.84 | 22.0 | False | None | None | False | None | False | 80164.48 | 0 |
3397816 | 119794 | None | item134 | Supplying of on load change over switches 4poles, AC 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 A as per specifications and as per directions of Engineer in charge. | Each | 17993.82 | 17993.82 | 1.0 | False | None | None | False | None | False | 17993.82 | 0 |
3397817 | 119794 | None | item135 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP as per specifications and as per directions of Engineer in charge. | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 |
3397818 | 119794 | None | item136 | Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm as per specifications and as per directions of Engineer in charge. | m | 466.1 | 466.1 | 15.0 | False | None | None | False | None | False | 6991.5 | 0 |
3397819 | 119794 | None | item137 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II Double Door 12 Way SP & N as per specifications and as per directions of Engineer in charge. | Each | 2748.22 | 2748.22 | 2.0 | False | None | None | False | None | False | 5496.44 | 0 |
3397820 | 119794 | None | item138 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32 40A 2 pole as per specifications and as per directions of Engineer in charge. | Each | 5379.62 | 5379.62 | 2.0 | False | None | None | False | None | False | 10759.24 | 0 |
3397821 | 119794 | None | item139 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A SP as per specifications and as per directions of Engineer in charge. | Each | 489.7 | 489.7 | 20.0 | False | None | None | False | None | False | 9794.0 | 0 |
3397822 | 119794 | None | item140 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III Double Door 4 Way TP & N as per specifications and as per directions of Engineer in charge. | Each | 4764.84 | 4764.84 | 4.0 | False | None | None | False | None | False | 19059.36 | 0 |
3397823 | 119794 | None | item141 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole as per specifications and as per directions of Engineer in charge. | Each | 6543.1 | 6543.1 | 4.0 | False | None | None | False | None | False | 26172.4 | 0 |
3397824 | 119794 | None | item142 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A DP as per specifications and as per directions of Engineer in charge. | Each | 872.02 | 872.02 | 4.0 | False | None | None | False | None | False | 3488.08 | 0 |
3397825 | 119794 | None | item143 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A SP as per specifications and as per directions of Engineer in charge. | Each | 489.7 | 489.7 | 24.0 | False | None | None | False | None | False | 11752.8 | 0 |
3397826 | 119794 | None | item144 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947 2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for
Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA as per specifications and as per directions of Engineer in charge. | Each | 10014.66 | 10014.66 | 4.0 | False | None | None | False | None | False | 40058.64 | 0 |
3397827 | 119794 | None | item145 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness and resistivity as per IS 3975 6 Sqmm, 4 Core as per specifications and as per directions of Engineer in charge. | Mtr | 304.44 | 304.44 | 50.0 | False | None | None | False | None | False | 15222.0 | 0 |