tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719831939000 | 1 | None | None | Buildings | Makali - Construction of Portico | 671153.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426496 | 121427 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m for FOOTING ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 123.97 | 123.97 | 58.32 | False | None | None | False | None | False | 7229.9304 | 0 | 3426497 | 121427 | None | code02 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 143.42 | 143.42 | 58.32 | False | None | None | False | None | False | 8364.2544 | 0 | 3426498 | 121427 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 323.3 | 323.3 | 48.41 | False | None | None | False | None | False | 15650.953 | 0 | 3426499 | 121427 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PCC FOR FOOTINGS & PLINTH BEAM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7279.03 | 7279.03 | 2.5 | False | None | None | False | None | False | 18197.575 | 0 | 3426500 | 121427 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for FOOTINGS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 8316.84 | 8316.84 | 7.41 | False | None | None | False | None | False | 61627.7844 | 0 | 3426501 | 121427 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for PEDESTALS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 8470.85 | 8470.85 | 0.72 | False | None | None | False | None | False | 6099.012 | 0 | 3426502 | 121427 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 13091.32 | 13091.32 | 2.01 | False | None | None | False | None | False | 26313.5532 | 0 | 3426503 | 121427 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC BEAMS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 12321.24 | 12321.24 | 3.12 | False | None | None | False | None | False | 38442.2688 | 0 | 3426504 | 121427 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 11551.16 | 11551.16 | 7.2 | False | None | None | False | None | False | 83168.352 | 0 | 3426505 | 121427 | None | code10 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | t | 108726.04 | 108726.04 | 2.33 | False | None | None | False | None | False | 253331.6732 | 0 | 3426506 | 121427 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1592.17 | 1592.17 | 39.6 | False | None | None | False | None | False | 63049.932 | 0 | 3426507 | 121427 | None | code12 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 424.17 | 424.17 | 79.2 | False | None | None | False | None | False | 33594.264 | 0 | 3426508 | 121427 | None | code13 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 747.47 | 747.47 | 64.0 | False | None | None | False | None | False | 47838.08 | 0 | 3426509 | 121427 | None | code14 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 64.42 | 64.42 | 128.0 | False | None | None | False | None | False | 8245.76 | 0 |
| 1719831939000 | 0 | None | None | Buildings | Makali - Internal Road Work | 803149.19 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426510 | 121428 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 115.46 | 115.46 | 82.5 | False | None | None | False | None | False | 9525.45 | 0 | 3426511 | 121428 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 294.13 | 294.13 | 27.5 | False | None | None | False | None | False | 8088.575 | 0 | 3426512 | 121428 | None | code03 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 103.31 | 103.31 | 110.0 | False | None | None | False | None | False | 11364.1 | 0 | 3426513 | 121428 | None | code04 | Box cutting / trenching the sub grade to proper slope, camber and removing inequalities including removing the stuff and depositing on the road side slopes (cutting of earthwork shall be paid separately in the respective item on the basis of classification of the excavation) including cost of all labour complete as per specifications. MORTH Chapter 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 2.43 | 2.43 | 275.0 | False | None | None | False | None | False | 668.25 | 0 | 3426514 | 121428 | None | code05 | Compaction of original ground with maximum of 6 passes of 8 to 10 tones power roller including filing in depression occurring during rolling including cost of all labour, HOM of machinery complete as per specifications. MORTH Chapter 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 7.29 | 7.29 | 275.0 | False | None | None | False | None | False | 2004.75 | 0 | 3426515 | 121428 | None | code06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 576.1 | 576.1 | 82.5 | False | None | None | False | None | False | 47528.25 | 0 | 3426516 | 121428 | None | code07 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading V Material ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 2867.13 | 2867.13 | 41.25 | False | None | None | False | None | False | 118269.1125 | 0 | 3426517 | 121428 | None | code08 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 11012.74 | 11012.74 | 55.0 | False | None | None | False | None | False | 605700.7 | 0 |
| 1719831939000 | 0 | None | None | Buildings | Makali - Drain Work | 960183.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426518 | 121429 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | ha | 477.65 | 477.65 | 16.5 | False | None | None | False | None | False | 7881.225 | 0 | 3426519 | 121429 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 123.97 | 123.97 | 105.6 | False | None | None | False | None | False | 13091.232 | 0 | 3426520 | 121429 | None | code03 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 164.08 | 164.08 | 132.0 | False | None | None | False | None | False | 21658.56 | 0 | 3426521 | 121429 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7279.03 | 7279.03 | 13.2 | False | None | None | False | None | False | 96083.196 | 0 | 3426522 | 121429 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -Base slab (VENT PORTION) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 8299.85 | 8299.85 | 13.2 | False | None | None | False | None | False | 109558.02 | 0 | 3426523 | 121429 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -Side wall ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 10878.44 | 10878.44 | 29.7 | False | None | None | False | None | False | 323089.668 | 0 | 3426524 | 121429 | None | code07 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel at 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 1127.89 | 1127.89 | 165.0 | False | None | None | False | None | False | 186101.85 | 0 | 3426525 | 121429 | None | code08 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) -GROUND FLOOR ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | t | 108726.04 | 108726.04 | 1.8645 | False | None | None | False | None | False | 202719.70158 | 0 |
| 1719831939000 | 1 | None | None | Buildings | Makali - Septic Tank | 882238.26 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426526 | 121430 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | ha | 477.65 | 477.65 | 27.06 | False | None | None | False | None | False | 12925.209 | 0 | 3426527 | 121430 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 115.46 | 115.46 | 13.53 | False | None | None | False | None | False | 1562.1738 | 0 | 3426528 | 121430 | None | code03 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum (Disposal of 10Km) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 164.08 | 164.08 | 13.53 | False | None | None | False | None | False | 2220.0024 | 0 | 3426529 | 121430 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7279.03 | 7279.03 | 2.48 | False | None | None | False | None | False | 18051.9944 | 0 | 3426530 | 121430 | None | code05 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. (M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) BOTTOM SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 8112.07 | 8112.07 | 3.312 | False | None | None | False | None | False | 26867.17584 | 0 | 3426531 | 121430 | None | code06 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications. (M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) TOP SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 11813.69 | 11813.69 | 3.084 | False | None | None | False | None | False | 36433.41996 | 0 | 3426532 | 121430 | None | code07 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications. (M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) RC WALL ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 13388.85 | 13388.85 | 15.345 | False | None | None | False | None | False | 205451.90325 | 0 | 3426533 | 121430 | None | code08 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Tonne | 108726.04 | 108726.04 | 3.485 | False | None | None | False | None | False | 378910.2494 | 0 | 3426534 | 121430 | None | code09 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 992.98 | 992.98 | 101.56 | False | None | None | False | None | False | 100847.0488 | 0 | 3426535 | 121430 | None | code10 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 392.57 | 392.57 | 20.56 | False | None | None | False | None | False | 8071.2392 | 0 | 3426536 | 121430 | None | code11 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 430.25 | 430.25 | 162.0 | False | None | None | False | None | False | 69700.5 | 0 | 3426537 | 121430 | None | code12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 41.12 | False | None | None | False | None | False | 5747.3424 | 0 | 3426538 | 121430 | None | code13 | C. I Manhole covers 24 x 24 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 2575.0 | 2575.0 | 6.0 | False | None | None | False | None | False | 15450.0 | 0 |
| 1719831939000 | 1 | None | None | Buildings | Akkuru - Renovation Work | 2378014.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426539 | 121431 | None | code01 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge. Of area beyond 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 318.43 | 318.43 | 42.42 | False | None | None | False | None | False | 13507.8006 | 0 | 3426540 | 121431 | None | code02 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area beyond ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 149.49 | 149.49 | 42.42 | False | None | None | False | None | False | 6341.3658 | 0 | 3426541 | 121431 | None | code03 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 44.97 | 44.97 | 118.84 | False | None | None | False | None | False | 5344.2348 | 0 | 3426542 | 121431 | None | code04 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 700.07 | 700.07 | 29.27 | False | None | None | False | None | False | 20491.0489 | 0 | 3426543 | 121431 | None | code05 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 60.77 | 60.77 | 59.42 | False | None | None | False | None | False | 3610.9534 | 0 | 3426544 | 121431 | None | code06 | Cleaning and washing of decorated wall surface with soap, soda and water including cost of materials, labour, complete as per specifications ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 6.08 | 6.08 | 1091.7 | False | None | None | False | None | False | 6637.536 | 0 | 3426545 | 121431 | None | code07 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 15.8 | 15.8 | 685.64 | False | None | None | False | None | False | 10833.112 | 0 | 3426546 | 121431 | None | code08 | Extra for removing white wash or colour wash by steel brushing and / or scraping, sand papering the ceiling and / or sloping roof surface smooth including repairs to scraches, cost of material, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 12.15 | 12.15 | 286.54 | False | None | None | False | None | False | 3481.461 | 0 | 3426547 | 121431 | None | code09 | Removing the old paint or polish from wood and / or wood based surface with paint remover of approved brand / manufacturer and making surface even including cost of materials, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 115.46 | 115.46 | 100.55 | False | None | None | False | None | False | 11609.503 | 0 | 3426548 | 121431 | None | code10 | Removing the old paint from steel and / or other metal surface with hand scraping and making surface even including cost of labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 147.06 | 147.06 | 34.5 | False | None | None | False | None | False | 5073.57 | 0 | 3426549 | 121431 | None | code11 | Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 484.94 | 484.94 | 93.31 | False | None | None | False | None | False | 45249.7514 | 0 | 3426550 | 121431 | None | code12 | Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., compl ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 18.23 | 18.23 | 195.84 | False | None | None | False | None | False | 3570.1632 | 0 | 3426551 | 121431 | None | code13 | Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 3.65 | 3.65 | 250.54 | False | None | None | False | None | False | 914.471 | 0 | 3426552 | 121431 | None | code14 | Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. vol- 2 (PWD SR 2023-24/P.No.207/20.104) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1185.02 | 1185.02 | 38.75 | False | None | None | False | None | False | 45919.525 | 0 | 3426553 | 121431 | None | code15 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.. ii) By Mechanical Means using Dozer. A) In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | ha | 477.65 | 477.65 | 1.08 | False | None | None | False | None | False | 515.862 | 0 | 3426554 | 121431 | None | code16 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 110.6 | 110.6 | 108.0 | False | None | None | False | None | False | 11944.8 | 0 | 3426555 | 121431 | None | code17 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine
mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other
appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm and down size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7587.74 | 7587.74 | 9.8 | False | None | None | False | None | False | 74359.852 | 0 | 3426556 | 121431 | None | code18 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per Cum for every 1.50 m height or part there off Deduct 5% per Cum if rollers are not used and tamping is done manually Add 8% per m cum for works under foul & sullage situation ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 576.1 | 576.1 | 90.0 | False | None | None | False | None | False | 51849.0 | 0 | 3426557 | 121431 | None | code19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 358.54 | 358.54 | 80.6 | False | None | None | False | None | False | 28898.324 | 0 | 3426558 | 121431 | None | code20 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 120.32 | 120.32 | 972.18 | False | None | None | False | None | False | 116972.6976 | 0 | 3426559 | 121431 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 121.54 | 121.54 | 729.13 | False | None | None | False | None | False | 88618.4602 | 0 | 3426560 | 121431 | None | code22 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 64.42 | 64.42 | 729.13 | False | None | None | False | None | False | 46970.5546 | 0 | 3426561 | 121431 | None | code23 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied at 1.43 l/ 10 Sqm) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge . -Ground Floor ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 134.91 | 134.91 | 698.41 | False | None | None | False | None | False | 94222.4931 | 0 | 3426562 | 121431 | None | code24 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied at 1.43 l/ 10 Sqm) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge . -Terrace Floor ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 136.25 | 136.25 | 120.41 | False | None | None | False | None | False | 16405.8625 | 0 | 3426563 | 121431 | None | code25 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1428.1 | 1428.1 | 102.88 | False | None | None | False | None | False | 146922.928 | 0 | 3426564 | 121431 | None | code26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1344.23 | 1344.23 | 80.6 | False | None | None | False | None | False | 108344.938 | 0 | 3426565 | 121431 | None | code27 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 10058.65 | 10058.65 | 8.51 | False | None | None | False | None | False | 85599.1115 | 0 | 3426566 | 121431 | None | code28 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 165.29 | 165.29 | 207.0 | False | None | None | False | None | False | 34215.03 | 0 | 3426567 | 121431 | None | code29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 42.66 | False | None | None | False | None | False | 5962.5882 | 0 | 3426568 | 121431 | None | code30 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 8184.5 | 8184.5 | 31.8 | False | None | None | False | None | False | 260267.1 | 0 | 3426569 | 121431 | None | code31 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 6950.87 | 6950.87 | 2.7 | False | None | None | False | None | False | 18767.349 | 0 | 3426570 | 121431 | None | code32 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 68.06 | 68.06 | 100.55 | False | None | None | False | None | False | 6843.433 | 0 | 3426571 | 121431 | None | code33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 100.55 | False | None | None | False | None | False | 14053.8735 | 0 | 3426572 | 121431 | None | code34 | Surface preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to give a tough elastomeric water proof membrane.System : providing and applying 1.2mm thick roller applied single component Bitumen Modified Polyurathene coating. NITOPROOF 600 or equivalent, having elongation capability of 450% as per ASTM D412, having Tensile strength 1.5 N/mm2 as per ASTM D412 , Tear Resistance of 15N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D2240. Waterproofing treatment to be provided after proper surface preparation as per manufacturer specification Protection of water proofing system with minimum 50mm thick screed and providing construction joints and sealing the same with PU sealant (CPWD) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1593.0 | 1593.0 | 390.33 | False | None | None | False | None | False | 621795.69 | 0 | 3426573 | 121431 | None | code35 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 6049.05 | 6049.05 | 2.0 | False | None | None | False | None | False | 12098.1 | 0 | 3426574 | 121431 | None | code36 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 478.87 | 478.87 | 66.5 | False | None | None | False | None | False | 31844.855 | 0 | 3426575 | 121431 | None | code37 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for: 110mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 115.46 | 115.46 | 66.5 | False | None | None | False | None | False | 7678.09 | 0 | 3426576 | 121431 | None | code38 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 25 LPH : Cabin Type - For 25 LPH : Cabin Type ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 36255.38 | 36255.38 | 1.0 | False | None | None | False | None | False | 36255.38 | 0 | 3426577 | 121431 | None | code39 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. vol- 2 (PWD SR 2023-24/P.No.95/11.57.2) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 137.34 | 137.34 | 79.2 | False | None | None | False | None | False | 10877.328 | 0 | 3426578 | 121431 | None | code40 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 63.2 | 63.2 | 18.0 | False | None | None | False | None | False | 1137.6 | 0 | 3426579 | 121431 | None | code41 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 3381.88 | 3381.88 | 4.0 | False | None | None | False | None | False | 13527.52 | 0 | 3426580 | 121431 | None | code42 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | l | 10.62 | 10.62 | 2000.0 | False | None | None | False | None | False | 21240.0 | 0 | 3426581 | 121431 | None | code43 | Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 2692.76 | 2692.76 | 4.0 | False | None | None | False | None | False | 10771.04 | 0 | 3426582 | 121431 | None | code44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 20 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 285.56 | 285.56 | 100.0 | False | None | None | False | None | False | 28556.0 | 0 | 3426583 | 121431 | None | code45 | Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - a, Economy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1443.14 | 1443.14 | 10.0 | False | None | None | False | None | False | 14431.4 | 0 | 3426584 | 121431 | None | code46 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a, Economy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1318.06 | 1318.06 | 10.0 | False | None | None | False | None | False | 13180.6 | 0 | 3426585 | 121431 | None | code47 | SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. - 19/20 mm dia 2 mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 81.42 | 81.42 | 100.0 | False | None | None | False | None | False | 8142.0 | 0 | 3426586 | 121431 | None | code48 | SupplyingandfixingofPVCcasingandcappingonthewallorceilingusingnecessarymaterialslikebends,junctionbox,elbows,screwsatan interval of 300 mm as required. - 25 MM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 41.3 | 41.3 | 50.0 | False | None | None | False | None | False | 2065.0 | 0 | 3426587 | 121431 | None | code49 | SupplyingPVCflexibleconduitpipe....mmdiafixingonsurfaceoverinvertedtaperedwoodenplugsorphillplugsorrawlplugsandclampedusingheavygaugesaddlesatanintervalof300mmusingNFscrews and on either end of the pipe terminated completely - 20 MM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 22.42 | 22.42 | 50.0 | False | None | None | False | None | False | 1121.0 | 0 | 3426588 | 121431 | None | code50 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.- Short point upto 3Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 336.3 | 336.3 | 10.0 | False | None | None | False | None | False | 3363.0 | 0 | 3426589 | 121431 | None | code51 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. - Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 464.92 | 464.92 | 10.0 | False | None | None | False | None | False | 4649.2 | 0 | 3426590 | 121431 | None | code52 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. - Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 672.6 | 672.6 | 10.0 | False | None | None | False | None | False | 6726.0 | 0 | 3426591 | 121431 | None | code53 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-6A SP Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 64.9 | 64.9 | 10.0 | False | None | None | False | None | False | 649.0 | 0 | 3426592 | 121431 | None | code54 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.- 6A Two Way Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 82.6 | 82.6 | 5.0 | False | None | None | False | None | False | 413.0 | 0 | 3426593 | 121431 | None | code55 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-6A Three Way 5 Pin Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 82.6 | 82.6 | 5.0 | False | None | None | False | None | False | 413.0 | 0 | 3426594 | 121431 | None | code56 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-16A SP Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 154.58 | 154.58 | 5.0 | False | None | None | False | None | False | 772.9 | 0 | 3426595 | 121431 | None | code57 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-16/6A combined plug and socket with control switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 257.24 | 257.24 | 5.0 | False | None | None | False | None | False | 1286.2 | 0 | 3426596 | 121431 | None | code58 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-Electronic stepped regulator ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 331.58 | 331.58 | 5.0 | False | None | None | False | None | False | 1657.9 | 0 | 3426597 | 121431 | None | code59 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.-16A Three Way 5 Pin Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 135.7 | 135.7 | 10.0 | False | None | None | False | None | False | 1357.0 | 0 | 3426598 | 121431 | None | code60 | Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete - 12" sweep (300 mm) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 3503.42 | 3503.42 | 4.0 | False | None | None | False | None | False | 14013.68 | 0 | 3426599 | 121431 | None | code61 | Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem. - 48" Sweep (1200 mm) Regular model ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 3521.12 | 3521.12 | 10.0 | False | None | None | False | None | False | 35211.2 | 0 | 3426600 | 121431 | None | code62 | SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hratLumenMaintenanceof70%,maximumlightintensityshouldbebetween60degreesto70degrees.CCT 5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaire IK08.PowerFactor 0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with inglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith........WSystemPowerconsumption.LEDEfficiency 1301m/w,nominalCRI 75.Luminairemanufacturershouldhavein- housefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osram make LED Source. - LED Streetlight 90 W (Item NO - 11.8.3, V-6) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 10454.8 | 10454.8 | 5.0 | False | None | None | False | None | False | 52274.0 | 0 | 3426601 | 121431 | None | code63 | Supplying&fixingofSurfacemountingtyperetrofittype-LEDtube.......WcomprisingofLEDlinearsourcewithCCT6500degreeK,CRI 70%.efficacy 80lumenperW,life 25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF 0.95,powerlossshould 5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. Polycarbonate/OPAL Acrylic Casing- 18W-20W (T8) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 805.94 | 805.94 | 25.0 | False | None | None | False | None | False | 20148.5 | 0 | 3426602 | 121431 | None | code64 | Fixingaceiling/wallmountingfanofallcapacitiesandalltypes,withnecessaryclampsand'S'hookmadeoutof15mmdiaMSrod,with5A.ceilingroseofapprovedqualitywithnecessarylengthof23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality,mounted on a suitable size wooden board and wired. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 3426603 | 121431 | None | code65 | Fixingoneexhaustfaninthenitchalreadyleftinthewallwithboltsandnutsand5A.ceilingrosewithsufficientlengthof23/0.0076inch PVC insulated twin core wire. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 580.56 | 580.56 | 4.0 | False | None | None | False | None | False | 2322.24 | 0 |
| 1719831939000 | 1 | None | None | Buildings | Ganakallu - Renovation Works | 2377717.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3426604 | 121432 | None | code01 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge. Of area beyond 3 sqm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 318.43 | 318.43 | 42.67 | False | None | None | False | None | False | 13587.4081 | 0 | 3426605 | 121432 | None | code02 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area beyond 3 sqm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 149.49 | 149.49 | 43.49 | False | None | None | False | None | False | 6501.3201 | 0 | 3426606 | 121432 | None | code03 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 44.97 | 44.97 | 118.91 | False | None | None | False | None | False | 5347.3827 | 0 | 3426607 | 121432 | None | code04 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 700.07 | 700.07 | 30.11 | False | None | None | False | None | False | 21079.1077 | 0 | 3426608 | 121432 | None | code05 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 60.77 | 60.77 | 59.87 | False | None | None | False | None | False | 3638.2999 | 0 | 3426609 | 121432 | None | code06 | Cleaning and washing of decorated wall surface with soap, soda and water including cost of materials, labour, complete as per specifications ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 6.08 | 6.08 | 1091.69 | False | None | None | False | None | False | 6637.4752 | 0 | 3426610 | 121432 | None | code07 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 15.8 | 15.8 | 681.13 | False | None | None | False | None | False | 10761.854 | 0 | 3426611 | 121432 | None | code08 | Extra for removing white wash or colour wash by steel brushing and / or scraping, sand papering the ceiling and / or sloping roof surface smooth including repairs to scraches, cost of material, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 12.15 | 12.15 | 287.66 | False | None | None | False | None | False | 3495.069 | 0 | 3426612 | 121432 | None | code09 | Removing the old paint or polish from wood and / or wood based surface with paint remover of approved brand / manufacturer and making surface even including cost of materials, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 115.46 | 115.46 | 100.548 | False | None | None | False | None | False | 11609.27208 | 0 | 3426613 | 121432 | None | code10 | Removing the old paint from steel and / or other metal surface with hand scraping and making surface even including cost of labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 147.06 | 147.06 | 34.49 | False | None | None | False | None | False | 5072.0994 | 0 | 3426614 | 121432 | None | code11 | Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 484.94 | 484.94 | 93.31 | False | None | None | False | None | False | 45249.7514 | 0 | 3426615 | 121432 | None | code12 | Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., compl ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 18.23 | 18.23 | 195.84 | False | None | None | False | None | False | 3570.1632 | 0 | 3426616 | 121432 | None | code13 | Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 3.65 | 3.65 | 250.54 | False | None | None | False | None | False | 914.471 | 0 | 3426617 | 121432 | None | code14 | Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1185.02 | 1185.02 | 38.745 | False | None | None | False | None | False | 45913.5999 | 0 | 3426618 | 121432 | None | code15 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.. ii) By Mechanical Means using Dozer. A) In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | ha | 477.65 | 477.65 | 1.08 | False | None | None | False | None | False | 515.862 | 0 | 3426619 | 121432 | None | code16 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 110.6 | 110.6 | 108.0 | False | None | None | False | None | False | 11944.8 | 0 | 3426620 | 121432 | None | code17 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine
mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other
appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm and down size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7587.74 | 7587.74 | 9.8 | False | None | None | False | None | False | 74359.852 | 0 | 3426621 | 121432 | None | code18 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per cum for every 1.50 m height or part there off Deduct 5% per cum if rollers are not used and tamping is done manually Add 8% per cum for works under foul & sullage situation ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 576.1 | 576.1 | 90.0 | False | None | None | False | None | False | 51849.0 | 0 | 3426622 | 121432 | None | code19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 358.54 | 358.54 | 80.6 | False | None | None | False | None | False | 28898.324 | 0 | 3426623 | 121432 | None | code20 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 120.32 | 120.32 | 968.8 | False | None | None | False | None | False | 116566.016 | 0 | 3426624 | 121432 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 121.54 | 121.54 | 726.6 | False | None | None | False | None | False | 88310.964 | 0 | 3426625 | 121432 | None | code22 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 64.42 | 64.42 | 726.6 | False | None | None | False | None | False | 46807.572 | 0 | 3426626 | 121432 | None | code23 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 sqm) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge . vol- 2-Ground Floor ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 134.91 | 134.91 | 698.41 | False | None | None | False | None | False | 94222.4931 | 0 | 3426627 | 121432 | None | code24 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 sqm) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge-Terrace Floor ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 136.26 | 136.26 | 120.408 | False | None | None | False | None | False | 16406.79408 | 0 | 3426628 | 121432 | None | code25 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1428.1 | 1428.1 | 102.88 | False | None | None | False | None | False | 146922.928 | 0 | 3426629 | 121432 | None | code26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1344.23 | 1344.23 | 80.6 | False | None | None | False | None | False | 108344.938 | 0 | 3426630 | 121432 | None | code27 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 10058.65 | 10058.65 | 8.5 | False | None | None | False | None | False | 85498.525 | 0 | 3426631 | 121432 | None | code28 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 165.29 | 165.29 | 207.0 | False | None | None | False | None | False | 34215.03 | 0 | 3426632 | 121432 | None | code29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 42.655 | False | None | None | False | None | False | 5961.88935 | 0 | 3426633 | 121432 | None | code30 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 8184.5 | 8184.5 | 31.795 | False | None | None | False | None | False | 260226.1775 | 0 | 3426634 | 121432 | None | code31 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 6950.87 | 6950.87 | 2.69 | False | None | None | False | None | False | 18697.8403 | 0 | 3426635 | 121432 | None | code32 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 68.06 | 68.06 | 100.548 | False | None | None | False | None | False | 6843.29688 | 0 | 3426636 | 121432 | None | code33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 100.548 | False | None | None | False | None | False | 14053.59396 | 0 | 3426637 | 121432 | None | code34 | Surface preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to give a tough elastomeric water proof membrane.System : providing and applying 1.2mm thick roller applied single component Bitumen Modified Polyurathene coating. NITOPROOF 600 or equivalent, having elongation capability of 450% as per ASTM D412, having Tensile strength 1.5 N/mm2 as per ASTM D412 , Tear Resistance of 15N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D2240. Waterproofing treatment to be provided after proper surface preparation as per manufacturer specification Protection of water proofing system with minimum 50mm thick screed and providing construction joints and sealing the same with PU sealant (CPWD) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1593.0 | 1593.0 | 390.33 | False | None | None | False | None | False | 621795.69 | 0 | 3426638 | 121432 | None | code35 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 6049.05 | 6049.05 | 2.0 | False | None | None | False | None | False | 12098.1 | 0 | 3426639 | 121432 | None | code36 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 478.87 | 478.87 | 66.5 | False | None | None | False | None | False | 31844.855 | 0 | 3426640 | 121432 | None | code37 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for: 110mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 115.46 | 115.46 | 66.5 | False | None | None | False | None | False | 7678.09 | 0 | 3426641 | 121432 | None | code38 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 25 LPH : Cabin Type ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 36255.38 | 36255.38 | 1.0 | False | None | None | False | None | False | 36255.38 | 0 | 3426642 | 121432 | None | code39 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 137.34 | 137.34 | 79.19 | False | None | None | False | None | False | 10875.9546 | 0 | 3426643 | 121432 | None | code40 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 63.2 | 63.2 | 18.0 | False | None | None | False | None | False | 1137.6 | 0 | 3426644 | 121432 | None | code41 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 3381.88 | 3381.88 | 4.0 | False | None | None | False | None | False | 13527.52 | 0 | 3426645 | 121432 | None | code42 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | l | 10.62 | 10.62 | 2000.0 | False | None | None | False | None | False | 21240.0 | 0 | 3426646 | 121432 | None | code43 | Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 2692.76 | 2692.76 | 4.0 | False | None | None | False | None | False | 10771.04 | 0 | 3426647 | 121432 | None | code44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 20 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 285.56 | 285.56 | 100.0 | False | None | None | False | None | False | 28556.0 | 0 | 3426648 | 121432 | None | code45 | Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - a, Economy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1443.14 | 1443.14 | 10.0 | False | None | None | False | None | False | 14431.4 | 0 | 3426649 | 121432 | None | code46 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a, Economy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1318.06 | 1318.06 | 10.0 | False | None | None | False | None | False | 13180.6 | 0 | 3426650 | 121432 | None | code47 | SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. - 19/20 mm dia 2 mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 81.42 | 81.42 | 100.0 | False | None | None | False | None | False | 8142.0 | 0 | 3426651 | 121432 | None | code48 | SupplyingandfixingofPVCcasingandcappingonthewallorceilingusingnecessarymaterialslikebends,junctionbox,elbows,screwsatan interval of 300 mm as required. - 25 MM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 41.3 | 41.3 | 50.0 | False | None | None | False | None | False | 2065.0 | 0 | 3426652 | 121432 | None | code49 | SupplyingPVCflexibleconduitpipe....mmdiafixingonsurfaceoverinvertedtaperedwoodenplugsorphillplugsorrawlplugsandclampedusingheavygaugesaddlesatanintervalof300mmusingNFscrews and on either end of the pipe terminated completely - 20 MM ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 22.42 | 22.42 | 50.0 | False | None | None | False | None | False | 1121.0 | 0 | 3426653 | 121432 | None | code50 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet-Short point upto 3Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 336.3 | 336.3 | 10.0 | False | None | None | False | None | False | 3363.0 | 0 | 3426654 | 121432 | None | code51 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet-Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 464.92 | 464.92 | 10.0 | False | None | None | False | None | False | 4649.2 | 0 | 3426655 | 121432 | None | code52 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet-Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 672.6 | 672.6 | 10.0 | False | None | None | False | None | False | 6726.0 | 0 | 3426656 | 121432 | None | code53 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board- 6A SP Switch (Item No - 3.14.1) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 64.9 | 64.9 | 10.0 | False | None | None | False | None | False | 649.0 | 0 | 3426657 | 121432 | None | code54 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board-6A Two Way Switch (Item No - 3.14.2) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 82.6 | 82.6 | 5.0 | False | None | None | False | None | False | 413.0 | 0 | 3426658 | 121432 | None | code55 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board-6A Three Way 5 Pin Socket (Item No - 3.14.3) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 82.6 | 82.6 | 5.0 | False | None | None | False | None | False | 413.0 | 0 | 3426659 | 121432 | None | code56 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board -16A SP Switch (Item No - 3.14.10) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 154.58 | 154.58 | 5.0 | False | None | None | False | None | False | 772.9 | 0 | 3426660 | 121432 | None | code57 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board -16/6A combined plug and socket with control switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 257.24 | 257.24 | 5.0 | False | None | None | False | None | False | 1286.2 | 0 | 3426661 | 121432 | None | code58 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board -Electronic stepped regulator ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 331.58 | 331.58 | 5.0 | False | None | None | False | None | False | 1657.9 | 0 | 3426662 | 121432 | None | code59 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board -16A Three Way 5 Pin Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 135.7 | 135.7 | 10.0 | False | None | None | False | None | False | 1357.0 | 0 | 3426663 | 121432 | None | code60 | Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete - 12" sweep (300 mm) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 3503.42 | 3503.42 | 4.0 | False | None | None | False | None | False | 14013.68 | 0 | 3426664 | 121432 | None | code61 | Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem. - 48" Sweep (1200 mm) Regular model ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 3521.12 | 3521.12 | 10.0 | False | None | None | False | None | False | 35211.2 | 0 | 3426665 | 121432 | None | code62 | SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr@LumenMaintenanceof70%,maximumlightintensityshouldbebetween60degreesto70degrees.CCT 5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaire IK08.PowerFactor 0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with inglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith........WSystemPowerconsumption.LEDEfficiency 1301m/w,nominalCRI 75.Luminairemanufacturershouldhavein- housefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osram make LED Source. - LED Streetlight 90 W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 10454.8 | 10454.8 | 5.0 | False | None | None | False | None | False | 52274.0 | 0 | 3426666 | 121432 | None | code63 | Supplying&fixingofSurfacemountingtyperetrofittype-LEDtube.......WcomprisingofLEDlinearsourcewithCCT6500degreeK,CRI 70%.efficacy 80lumenperW,life 25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF 0.95,powerlossshould 5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. Polycarbonate/OPAL Acrylic Casing- 18W-20W (T8) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 805.94 | 805.94 | 25.0 | False | None | None | False | None | False | 20148.5 | 0 | 3426667 | 121432 | None | code64 | Fixingaceiling/wallmountingfanofallcapacitiesandalltypes,withnecessaryclampsand'S'hookmadeoutof15mmdiaMSrod,with5A.ceilingroseofapprovedqualitywithnecessarylengthof23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality,mounted on a suitable size wooden board and wired. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 3426668 | 121432 | None | code65 | Fixingoneexhaustfaninthenitchalreadyleftinthewallwithboltsandnutsand5A.ceilingrosewithsufficientlengthof23/0.0076inch PVC insulated twin core wire. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 580.56 | 580.56 | 4.0 | False | None | None | False | None | False | 2322.24 | 0 |
|
|
---|