createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719842199879
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4100.00
emd340000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-07-2024 17:30:00
tenderQueryClose08-07-2024 11:30:41
technicalBidOpen20-07-2024 11:30:00
publishedDate01-07-2024 19:54:48
publishedByPostKSTIDC_MD_HOFF_BNG
publishedByUserKPE20042 - PRAKASH S
bidValidityPeriod90
noOfCalls1
preBidMeetingDate08-07-2024 11:30:36
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMANAGING DIRECTOR
splitEmdRequiredYnTrue
emdBankGuarantee240000.00
emdCash100000.00
bgValidityPeriod270
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08028366540
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719842199920
version4
createdDateNone
modifiedDateNone
tenderNumberKSTIDC/2024-25/BD/WORK_INDENT2
titleConstruction of Administrative building, Power loom and Marketing Centre at Udyambag, Belagavi
descriptionConstruction of Administrative building, Power loom and Marketing Centre at Udyambag, Belagavi
categoryWORKS
categoryTextWorks
ecv16361510.91
deptNameKarnataka State Textile Infrastructure Development Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2631
locationNameKSCDRC Head Office Bangalore
provisionalAmount16940065.07
groupOverheadTotalNone
fileNumberKSTIDCL/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17198422000000NoneNoneBuildingsGROUND FLOOR8572394.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430302121543Nonecode01Earth work in surface excavation for stripping, seating of bund, Road way, bymanual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Sqm99.7599.75688.7376FalseNoneNoneFalseNoneFalse68701.57560
3430303121543Nonecode02Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum107.1107.1621.94FalseNoneNoneFalseNoneFalse66609.7740
3430304121543Nonecode03Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -do- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8562.25FalseNoneNoneFalseNoneFalse406358.66250
3430305121543Nonecode04Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.027185.02101.616FalseNoneNoneFalseNoneFalse730112.992320
3430306121543Nonecode05Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9979.29979.228.77FalseNoneNoneFalseNoneFalse287101.5840
3430307121543Nonecode06Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12214.7512214.7521.43FalseNoneNoneFalseNoneFalse261762.09250
3430308121543Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam & LintelCum11496.2411496.2427.94FalseNoneNoneFalseNoneFalse321204.94560
3430309121543Nonecode08Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Roof Slab.Cum10777.7210777.7257.714FalseNoneNoneFalseNoneFalse622025.332080
3430310121543Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for StaircaseCum10777.710777.73.45FalseNoneNoneFalseNoneFalse37183.0650
3430311121543Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for ChajjaCum10418.4610418.461.38FalseNoneNoneFalseNoneFalse14377.47480
3430312121543Nonecode11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (a) BuildingsMT93929.8593929.8528.25FalseNoneNoneFalseNoneFalse2653518.26250
3430313121543Nonecode12Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.952.5376FalseNoneNoneFalseNoneFalse440102.221440
3430314121543Nonecode13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. & Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.Sqm1212.751212.75143.58FalseNoneNoneFalseNoneFalse174126.6450
3430315121543Nonecode14Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3584.006FalseNoneNoneFalseNoneFalse163112.87580
3430316121543Nonecode15Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.10.4607FalseNoneNoneFalseNoneFalse60080.854470
3430317121543Nonecode16Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1066.81066.88.0FalseNoneNoneFalseNoneFalse8534.40
3430318121543Nonecode17Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2628.152628.1512.0FalseNoneNoneFalseNoneFalse31537.80
3430319121543Nonecode18Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 40 mm thick both side TeakSqm5208.05208.04.83FalseNoneNoneFalseNoneFalse25154.640
3430320121543Nonecode19Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teakSqm4245.154245.1515.57FalseNoneNoneFalseNoneFalse66096.98550
3430321121543Nonecode20Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Rmtr333.9333.915.29FalseNoneNoneFalseNoneFalse5105.3310
3430322121543Nonecode21Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelamSqm2484.32484.35.227FalseNoneNoneFalseNoneFalse12985.43610
3430323121543Nonecode22Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Kg192.15192.151034.37FalseNoneNoneFalseNoneFalse198754.19550
3430324121543Nonecode23Providing & fixing of 3-track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Sqm7070.77070.757.465FalseNoneNoneFalseNoneFalse406317.77550
3430325121543Nonecode24Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm221.55221.55387.48FalseNoneNoneFalseNoneFalse85846.1940
3430326121543Nonecode25Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.75809.753FalseNoneNoneFalseNoneFalse216811.365750
3430327121543Nonecode26Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in charge.Sqm404.25404.25324.576FalseNoneNoneFalseNoneFalse131209.8480
3430328121543Nonecode27Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.01197.23FalseNoneNoneFalseNoneFalse125709.150
3430329121543Nonecode28Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Sqm1202.251202.25168.3018FalseNoneNoneFalseNoneFalse202340.839050
3430330121543Nonecode29Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.Sqm840.0840.024.02FalseNoneNoneFalseNoneFalse20176.80
3430331121543Nonecode30Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.39.6FalseNoneNoneFalseNoneFalse11148.480
3430332121543Nonecode31Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1521.451521.4532.034FalseNoneNoneFalseNoneFalse48738.12930
3430333121543Nonecode32Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5594.45594.427.405FalseNoneNoneFalseNoneFalse153314.5320
3430334121543Nonecode33Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.Sqm171.15171.151197.23FalseNoneNoneFalseNoneFalse204905.91450
3430335121543Nonecode34Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7324.576FalseNoneNoneFalseNoneFalse59300.03520
3430336121543Nonecode35Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm175.35175.3597.97FalseNoneNoneFalseNoneFalse17179.03950
3430337121543Nonecode36Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25249.2FalseNoneNoneFalseNoneFalse147837.90
3430338121543Nonecode37Providing and injecting chemical emulsion for Pre constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.9412.26FalseNoneNoneFalseNoneFalse51079.0140
3430339121543Nonecode38Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.No1104.61104.611.0FalseNoneNoneFalseNoneFalse12150.60
3430340121543Nonecode39Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNo248.85248.8522.0FalseNoneNoneFalseNoneFalse5474.70
3430341121543Nonecode40Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)No288.75288.7533.0FalseNoneNoneFalseNoneFalse9528.750
3430342121543Nonecode41Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mmNo456.75456.7511.0FalseNoneNoneFalseNoneFalse5024.250
3430343121543Nonecode42Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNo57.7557.758.0FalseNoneNoneFalseNoneFalse462.00
3430344121543Nonecode43Providing and fixing bright finished brass handles with screws etc. complete: -do- Bright finished brass latchNo299.25299.2511.0FalseNoneNoneFalseNoneFalse3291.750
17198422000000NoneNoneBuildingsFIRST FLOOR4970152.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430345121544Nonecode01Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9979.29979.217.8848FalseNoneNoneFalseNoneFalse178475.996160
3430346121544Nonecode02Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam & LintelCum11611.211611.227.945FalseNoneNoneFalseNoneFalse324474.9840
3430347121544Nonecode03Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Roof Slab.Cum10885.510885.557.7148FalseNoneNoneFalseNoneFalse628254.45540
3430348121544Nonecode04Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for StaircaseCum10885.510885.53.454FalseNoneNoneFalseNoneFalse37598.5170
3430349121544Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -do- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for ChajjaCum10522.6510522.651.3859FalseNoneNoneFalseNoneFalse14583.3406350
3430350121544Nonecode06Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (a) BuildingsMT94869.1494869.1410.7FalseNoneNoneFalseNoneFalse1015099.7980
3430351121544Nonecode07Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8460.668460.6660.12FalseNoneNoneFalseNoneFalse508654.87920
3430352121544Nonecode08Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. & Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.Sqm1224.871224.8747.028FalseNoneNoneFalseNoneFalse57603.186360
3430353121544Nonecode09Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum131716.22131716.220.15FalseNoneNoneFalseNoneFalse19757.4330
3430354121544Nonecode10Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1077.461077.461.0FalseNoneNoneFalseNoneFalse1077.460
3430355121544Nonecode11Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 40 mm thick both side TeakSqm5260.085260.084.83FalseNoneNoneFalseNoneFalse25406.18640
3430356121544Nonecode12Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet Mtred cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Rmtr337.23337.2320.4FalseNoneNoneFalseNoneFalse6879.4920
3430357121544Nonecode13Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelamSqm2509.142509.146.9699FalseNoneNoneFalseNoneFalse17488.4548860
3430358121544Nonecode14Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Kg194.07194.071034.37FalseNoneNoneFalseNoneFalse200740.18590
3430359121544Nonecode15Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7141.47141.448.96FalseNoneNoneFalseNoneFalse349642.9440
3430360121544Nonecode16Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm223.76223.76387.48FalseNoneNoneFalseNoneFalse86702.52480
3430361121544Nonecode17Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm270.42270.42410.268FalseNoneNoneFalseNoneFalse110944.672560
3430362121544Nonecode18Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in charge.Sqm408.29408.29494.63FalseNoneNoneFalseNoneFalse201952.48270
3430363121544Nonecode19Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm106.05106.05797.7482FalseNoneNoneFalseNoneFalse84601.196610
3430364121544Nonecode20Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Sqm1203.451203.45354.502FalseNoneNoneFalseNoneFalse426625.43190
3430365121544Nonecode21Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm1172.911172.919.6FalseNoneNoneFalseNoneFalse11259.9360
3430366121544Nonecode22Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1536.661536.6632.034FalseNoneNoneFalseNoneFalse49225.366440
3430367121544Nonecode23Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5650.345650.3422.949FalseNoneNoneFalseNoneFalse129669.652660
3430368121544Nonecode24Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.Sqm172.86172.861197.4FalseNoneNoneFalseNoneFalse206982.5640
3430369121544Nonecode25Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm184.52184.52494.631FalseNoneNoneFalseNoneFalse91269.312120
3430370121544Nonecode26Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm177.1177.157.465FalseNoneNoneFalseNoneFalse10177.05150
3430371121544Nonecode27Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg599.18599.18235.2FalseNoneNoneFalseNoneFalse140927.1360
3430372121544Nonecode28Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.No1115.641115.641.0FalseNoneNoneFalseNoneFalse1115.640
3430373121544Nonecode29Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNo251.33251.334.0FalseNoneNoneFalseNoneFalse1005.320
3430374121544Nonecode30Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)No291.63291.636.0FalseNoneNoneFalseNoneFalse1749.780
3430375121544Nonecode31Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mmNo461.31461.312.0FalseNoneNoneFalseNoneFalse922.620
3430376121544Nonecode32Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNo58.3258.322.0FalseNoneNoneFalseNoneFalse116.640
3430377121544Nonecode33Providing and fixing bright finished brass handles with screws etc. complete: - Bright finished brass latchNo302.24302.241.0FalseNoneNoneFalseNoneFalse302.240
3430378121544Nonecode34Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg119.83119.8375.0FalseNoneNoneFalseNoneFalse8987.250
3430379121544Nonecode35Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm602.36602.3633.0FalseNoneNoneFalseNoneFalse19877.880
17198422000000NoneNoneBuildingsWATER SUPPLY & SANITARY223852.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430380121545Nonecode01Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum275.1275.132.13FalseNoneNoneFalseNoneFalse8838.9630
3430381121545Nonecode02Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia PipesMtr333.9333.957.0FalseNoneNoneFalseNoneFalse19032.30
3430382121545Nonecode03Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia PipesMtr191.1191.157.5FalseNoneNoneFalseNoneFalse10988.250
3430383121545Nonecode04Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.Ltr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3430384121545Nonecode05Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
3430385121545Nonecode06Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100mm nominal dia pipesMtr404.25404.2535.0FalseNoneNoneFalseNoneFalse14148.750
3430386121545Nonecode07Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm nominal dia pipesMtr303.45303.4535.0FalseNoneNoneFalseNoneFalse10620.750
3430387121545Nonecode08Providing and fixing brass bib cock of approved quality : 15 mm nominal boreNo300.3300.37.0FalseNoneNoneFalseNoneFalse2102.10
3430388121545Nonecode09Providing and fixing brass stop cock of approved quality : 15 mm nominal boreNo309.75309.756.0FalseNoneNoneFalseNoneFalse1858.50
3430389121545Nonecode10Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreNo576.45576.452.0FalseNoneNoneFalseNoneFalse1152.90
3430390121545Nonecode11Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5No1791.31791.34.0FalseNoneNoneFalseNoneFalse7165.20
3430391121545Nonecode12Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5No5924.15924.14.0FalseNoneNoneFalseNoneFalse23696.40
3430392121545Nonecode13Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : - W.C. pan with ISI marked white solid plastic seat and lidNo6275.856275.854.0FalseNoneNoneFalseNoneFalse25103.40
3430393121545Nonecode14Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : - One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach4676.74676.72.0FalseNoneNoneFalseNoneFalse9353.40
3430394121545Nonecode15Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: -do- White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tapEach2462.252462.254.0FalseNoneNoneFalseNoneFalse9849.00
3430395121545Nonecode16Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : - 470x420 mm bowl depth 178 mmEach2628.152628.152.0FalseNoneNoneFalseNoneFalse5256.30
3430396121545Nonecode17Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : - Rectangular shape 453x357 mmEach1068.91068.94.0FalseNoneNoneFalseNoneFalse4275.60
3430397121545Nonecode18Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each520.8520.86.0FalseNoneNoneFalseNoneFalse3124.80
3430398121545Nonecode19Providing Submersibel Pump 1 H.P.No30000.030000.01.0FalseNoneNoneFalseNoneFalse30000.00
3430399121545Nonecode20Providing and fixing R.C.C. Septic Tank 2.50 m x 1.20 m dia. Precast in place including excavation etc., complete.No12000.012000.01.0FalseNoneNoneFalseNoneFalse12000.00
3430400121545Nonecode21Construction of Sonapit - 1.20 x 1.20 x 2.00 m. with boulders, & Sand etc.,No5000.05000.01.0FalseNoneNoneFalseNoneFalse5000.00
17198422000000NoneNoneBuildingsIV) FOR U.G. SUMP & RAIN WATER HARVESTING346234.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430401121546Nonecode01Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum107.1107.153.5325FalseNoneNoneFalseNoneFalse5733.330750
3430402121546Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.66FalseNoneNoneFalseNoneFalse10836.2310
3430403121546Nonecode03Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.Sqm1212.751212.7535.19FalseNoneNoneFalseNoneFalse42676.67250
3430404121546Nonecode04Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specificationsCum10777.7210777.729.2FalseNoneNoneFalseNoneFalse99155.0240
3430405121546Nonecode05Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - BuildingsMT93929.8593929.851.1FalseNoneNoneFalseNoneFalse103322.8350
3430406121546Nonecode06Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7595.75FalseNoneNoneFalseNoneFalse25637.06250
3430407121546Nonecode07Rectangular cover 455x610 mm with frame (low duty) (inside)No1470.01470.02.0FalseNoneNoneFalseNoneFalse2940.00
3430408121546Nonecode08Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diaMtrRmtr305.55305.5599.2FalseNoneNoneFalseNoneFalse30310.560
3430409121546Nonecode09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.320.13FalseNoneNoneFalseNoneFalse5622.3090
3430410121546Nonecode10Recharging PointNo20000.020000.01.0FalseNoneNoneFalseNoneFalse20000.00
17198422000000NoneNoneBuildingsFOR DISMANTLING OF EXISTING STRUCTURE462915.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430411121547Nonecode01Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. - Asbestos cement sheetSqm53.5553.55422.1FalseNoneNoneFalseNoneFalse22603.4550
3430412121547Nonecode02Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge.Kg4.24.23031.2FalseNoneNoneFalseNoneFalse12731.040
3430413121547Nonecode03Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge.- Of area 3 m² and belowCum252.0252.046.08FalseNoneNoneFalseNoneFalse11612.160
3430414121547Nonecode04Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortarCum1080.451080.45157.785FalseNoneNoneFalseNoneFalse170478.803250
3430415121547Nonecode05Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2547.32547.32.651FalseNoneNoneFalseNoneFalse6752.89230
3430416121547Nonecode06Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.Cum763.35763.352.65FalseNoneNoneFalseNoneFalse2022.87750
3430417121547Nonecode07Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. - In cement mortarCum1768.21768.2101.5335FalseNoneNoneFalseNoneFalse179531.53470
3430418121547Nonecode08Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)Cum1080.451080.4552.925FalseNoneNoneFalseNoneFalse57182.816250
17198422000000NoneNoneBuildingsVI) FOR FOR COMPOUND WALL & GATE650337.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430419121548Nonecode01Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum271.95271.9531.103FalseNoneNoneFalseNoneFalse8458.460850
3430420121548Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.853.45FalseNoneNoneFalseNoneFalse22521.08250
3430421121548Nonecode03Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7133.577133.575.832FalseNoneNoneFalseNoneFalse41602.980240
3430422121548Nonecode04Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9965.559965.556.49FalseNoneNoneFalseNoneFalse64676.41950
3430423121548Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. -M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11834.5511834.553.8088FalseNoneNoneFalseNoneFalse45075.434040
3430424121548Nonecode06Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.919.4534FalseNoneNoneFalseNoneFalse162959.186460
3430425121548Nonecode07Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Cum267.75267.75133.73FalseNoneNoneFalseNoneFalse35806.20750
3430426121548Nonecode08Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg142.8142.81191.49FalseNoneNoneFalseNoneFalse170144.7720
3430427121548Nonecode09Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7133.73FalseNoneNoneFalseNoneFalse24432.4710
3430428121548Nonecode10Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5482.055482.0512.8FalseNoneNoneFalseNoneFalse70170.240
3430429121548Nonecode11Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm175.35175.3525.61FalseNoneNoneFalseNoneFalse4490.71350
17198422000001NoneNoneBuildingsELECTRICAL WORKS81354.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430430121549Nonecode01Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20 mm dia 2 mm thickMtr66.066.0350.0FalseNoneNoneFalseNoneFalse23100.00
3430431121549Nonecode02Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25 mm dia 2 mm thickMtr78.078.0450.0FalseNoneNoneFalseNoneFalse35100.00
3430432121549Nonecode03Supplying heavy gauge PVCConduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickMtr68.068.0150.0FalseNoneNoneFalseNoneFalse10200.00
3430433121549Nonecode05Supplying and fixing PVC/metal conduit Deep junction 19/20 mm deep Junction boxMtr49.049.065.0FalseNoneNoneFalseNoneFalse3185.00
3430434121549Nonecode06Supplying and fixing PVC/metal conduit Deep junction 25 mm deep Junction boxMtr56.056.032.0FalseNoneNoneFalseNoneFalse1792.00
3430435121549Nonecode07Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallMtr29.029.0150.0FalseNoneNoneFalseNoneFalse4350.00
3430436121549Nonecode08Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.031.0FalseNoneNoneFalseNoneFalse3627.00
17198422000001NoneNoneBuildingsPoint wiring using Copper wire without switch.594438.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430437121550Nonecode01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint269.0269.023.0FalseNoneNoneFalseNoneFalse6187.00
3430438121550Nonecode02Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint379.0379.037.0FalseNoneNoneFalseNoneFalse14023.00
3430439121550Nonecode03Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint555.0555.038.0FalseNoneNoneFalseNoneFalse21090.00
3430440121550Nonecode04Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2Mtr26.026.01650.0FalseNoneNoneFalseNoneFalse42900.00
3430441121550Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2Mtr42.042.02500.0FalseNoneNoneFalseNoneFalse105000.00
3430442121550Nonecode06Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2Mtr63.063.03500.0FalseNoneNoneFalseNoneFalse220500.00
3430443121550Nonecode07Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2Mtr92.092.0600.0FalseNoneNoneFalseNoneFalse55200.00
3430444121550Nonecode08Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 10 mm2Mtr167.0167.0100.0FalseNoneNoneFalseNoneFalse16700.00
3430445121550Nonecode09Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 WayEach138.0138.07.0FalseNoneNoneFalseNoneFalse966.00
3430446121550Nonecode10Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.026.0FalseNoneNoneFalseNoneFalse5720.00
3430447121550Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 0-12 WayEach319.0319.028.0FalseNoneNoneFalseNoneFalse8932.00
3430448121550Nonecode12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 2 ModuleEach137.0137.07.0FalseNoneNoneFalseNoneFalse959.00
3430449121550Nonecode13Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 6 ModuleEach234.0234.026.0FalseNoneNoneFalseNoneFalse6084.00
3430450121550Nonecode14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 ModuleEach344.0344.028.0FalseNoneNoneFalseNoneFalse9632.00
3430451121550Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.0169.0FalseNoneNoneFalseNoneFalse17238.00
3430452121550Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchEach166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
3430453121550Nonecode17Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socketEach171.0171.078.0FalseNoneNoneFalseNoneFalse13338.00
3430454121550Nonecode18Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - Stepped Fan Regulator Two ModuleEach357.0357.031.0FalseNoneNoneFalseNoneFalse11067.00
3430455121550Nonecode19Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3430456121550Nonecode20Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - 6/16A Universal SocketEach236.0236.020.0FalseNoneNoneFalseNoneFalse4720.00
3430457121550Nonecode21Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - TV/Telephone SocketEach156.0156.05.0FalseNoneNoneFalseNoneFalse780.00
3430458121550Nonecode22Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A DPEach739.0739.06.0FalseNoneNoneFalseNoneFalse4434.00
3430459121550Nonecode23Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 A TPNEach3088.03088.08.0FalseNoneNoneFalseNoneFalse24704.00
17198422000001NoneNoneBuildingsELECTRICAL WORK CONTD459832.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430460121551Nonecode01Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & NEach1524.01524.01.0FalseNoneNoneFalseNoneFalse1524.00
3430461121551Nonecode02Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 12 Way SP & NEach2329.02329.01.0FalseNoneNoneFalseNoneFalse2329.00
3430462121551Nonecode03Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TP & NEach4038.04038.02.0FalseNoneNoneFalseNoneFalse8076.00
3430463121551Nonecode04Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boardEach1.01.01.0FalseNoneNoneFalseNoneFalse1.00
3430464121551Nonecode05Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 poleEach4559.04559.01.0FalseNoneNoneFalseNoneFalse4559.00
3430465121551Nonecode06Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC SupplyEach1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3430466121551Nonecode07Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach2984.02984.031.0FalseNoneNoneFalseNoneFalse92504.00
3430467121551Nonecode08Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.Mtr44.044.0150.0FalseNoneNoneFalseNoneFalse6600.00
3430468121551Nonecode09Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 - 20/22 WEach690.0690.061.0FalseNoneNoneFalseNoneFalse42090.00
3430469121551Nonecode10Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Ding Dong BellEach246.0246.04.0FalseNoneNoneFalseNoneFalse984.00
3430470121551Nonecode11Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the Mtr board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.08.0FalseNoneNoneFalseNoneFalse28080.00
3430471121551Nonecode12GI/Copper strips 25 x 3 mm GI stripMtr82.082.0160.0FalseNoneNoneFalseNoneFalse13120.00
3430472121551Nonecode13Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / GirdersEach122.0122.061.0FalseNoneNoneFalseNoneFalse7442.00
3430473121551Nonecode14Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.031.0FalseNoneNoneFalseNoneFalse5301.00
3430474121551Nonecode15Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
3430475121551Nonecode16Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3430476121551Nonecode17Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.03.0FalseNoneNoneFalseNoneFalse1686.00
3430477121551Nonecode18Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3430478121551Nonecode19Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- FOUR Pole - 125 A 25 kAEach10341.010341.02.0FalseNoneNoneFalseNoneFalse20682.00
3430479121551Nonecode20Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete - 100 A 4 x 30 x 6 mm Aluminium StripsMtr2465.02465.01.0FalseNoneNoneFalseNoneFalse2465.00
3430480121551Nonecode21Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40 x 40 x 6 mmMtr305.0305.012.0FalseNoneNoneFalseNoneFalse3660.00
3430481121551Nonecode22Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 14 SWGcm0.50.5160000.0FalseNoneNoneFalseNoneFalse80000.00
3430482121551Nonecode231.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km178973.23178973.230.3FalseNoneNoneFalseNoneFalse53691.9690
3430483121551Nonecode241.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - HDPE pipe grade PE100-PN 10, 63mmMtr132.0132.0280.0FalseNoneNoneFalseNoneFalse36960.00
3430484121551Nonecode25Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - 35 to 95 SqmmKm31138.5431138.540.3FalseNoneNoneFalseNoneFalse9341.5620
3430485121551Nonecode26Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED SourceLED Streetlight 70WEach5992.05992.04.0FalseNoneNoneFalseNoneFalse23968.00
17198430870000NoneNoneElectricalelectrical work1135624.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430513121553Nonecode01Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20 mm dia 2 mm thickMtr66.066.0350.0FalseNoneNoneFalseNoneFalse23100.00
3430487121553Nonecode01Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & NEach1524.01524.01.0FalseNoneNoneFalseNoneFalse1524.00
3430520121553Nonecode01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint269.0269.023.0FalseNoneNoneFalseNoneFalse6187.00
3430488121553Nonecode02Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 12 Way SP & NEach2329.02329.01.0FalseNoneNoneFalseNoneFalse2329.00
3430514121553Nonecode02Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25 mm dia 2 mm thickMtr78.078.0450.0FalseNoneNoneFalseNoneFalse35100.00
3430521121553Nonecode02Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint379.0379.037.0FalseNoneNoneFalseNoneFalse14023.00
3430489121553Nonecode03Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TP & NEach4038.04038.02.0FalseNoneNoneFalseNoneFalse8076.00
3430515121553Nonecode03Supplying heavy gauge PVCConduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickMtr68.068.0150.0FalseNoneNoneFalseNoneFalse10200.00
3430522121553Nonecode03Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint555.0555.038.0FalseNoneNoneFalseNoneFalse21090.00
3430490121553Nonecode04Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boardEach1.01.01.0FalseNoneNoneFalseNoneFalse1.00
3430523121553Nonecode04Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2Mtr26.026.01650.0FalseNoneNoneFalseNoneFalse42900.00
3430516121553Nonecode05Supplying and fixing PVC/metal conduit Deep junction 19/20 mm deep Junction boxMtr49.049.065.0FalseNoneNoneFalseNoneFalse3185.00
3430517121553Nonecode06Supplying and fixing PVC/metal conduit Deep junction 25 mm deep Junction boxMtr56.056.032.0FalseNoneNoneFalseNoneFalse1792.00
3430524121553Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2Mtr42.042.02500.0FalseNoneNoneFalseNoneFalse105000.00
3430491121553Nonecode05Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 poleEach4559.04559.01.0FalseNoneNoneFalseNoneFalse4559.00
3430492121553Nonecode06Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC SupplyEach1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3430525121553Nonecode06Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2Mtr63.063.03500.0FalseNoneNoneFalseNoneFalse220500.00
3430518121553Nonecode07Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallMtr29.029.0150.0FalseNoneNoneFalseNoneFalse4350.00
3430493121553Nonecode07Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach2984.02984.031.0FalseNoneNoneFalseNoneFalse92504.00
3430526121553Nonecode07Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2Mtr92.092.0600.0FalseNoneNoneFalseNoneFalse55200.00
3430519121553Nonecode08Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.031.0FalseNoneNoneFalseNoneFalse3627.00
3430494121553Nonecode08Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.Mtr44.044.0150.0FalseNoneNoneFalseNoneFalse6600.00
3430527121553Nonecode08Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 10 mm2Mtr167.0167.0100.0FalseNoneNoneFalseNoneFalse16700.00
3430495121553Nonecode09Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 - 20/22 WEach690.0690.061.0FalseNoneNoneFalseNoneFalse42090.00
3430528121553Nonecode09Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 WayEach138.0138.07.0FalseNoneNoneFalseNoneFalse966.00
3430496121553Nonecode10Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Ding Dong BellEach246.0246.04.0FalseNoneNoneFalseNoneFalse984.00
3430529121553Nonecode10Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.026.0FalseNoneNoneFalseNoneFalse5720.00
3430530121553Nonecode11Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 0-12 WayEach319.0319.028.0FalseNoneNoneFalseNoneFalse8932.00
3430497121553Nonecode11Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the Mtr board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.08.0FalseNoneNoneFalseNoneFalse28080.00
3430498121553Nonecode12GI/Copper strips 25 x 3 mm GI stripMtr82.082.0160.0FalseNoneNoneFalseNoneFalse13120.00
3430531121553Nonecode12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 2 ModuleEach137.0137.07.0FalseNoneNoneFalseNoneFalse959.00
3430499121553Nonecode13Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / GirdersEach122.0122.061.0FalseNoneNoneFalseNoneFalse7442.00
3430532121553Nonecode13Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 6 ModuleEach234.0234.026.0FalseNoneNoneFalseNoneFalse6084.00
3430500121553Nonecode14Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.031.0FalseNoneNoneFalseNoneFalse5301.00
3430533121553Nonecode14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 ModuleEach344.0344.028.0FalseNoneNoneFalseNoneFalse9632.00
3430501121553Nonecode15Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
3430534121553Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.0169.0FalseNoneNoneFalseNoneFalse17238.00
3430502121553Nonecode16Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3430535121553Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchEach166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
3430503121553Nonecode17Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.03.0FalseNoneNoneFalseNoneFalse1686.00
3430536121553Nonecode17Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socketEach171.0171.078.0FalseNoneNoneFalseNoneFalse13338.00
3430537121553Nonecode18Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - Stepped Fan Regulator Two ModuleEach357.0357.031.0FalseNoneNoneFalseNoneFalse11067.00
3430504121553Nonecode18Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3430505121553Nonecode19Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- FOUR Pole - 125 A 25 kAEach10341.010341.02.0FalseNoneNoneFalseNoneFalse20682.00
3430538121553Nonecode19Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3430506121553Nonecode20Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete - 100 A 4 x 30 x 6 mm Aluminium StripsMtr2465.02465.01.0FalseNoneNoneFalseNoneFalse2465.00
3430539121553Nonecode20Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - 6/16A Universal SocketEach236.0236.020.0FalseNoneNoneFalseNoneFalse4720.00
3430507121553Nonecode21Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40 x 40 x 6 mmMtr305.0305.012.0FalseNoneNoneFalseNoneFalse3660.00
3430540121553Nonecode21Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket - TV/Telephone SocketEach156.0156.05.0FalseNoneNoneFalseNoneFalse780.00
3430508121553Nonecode22Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 14 SWGcm0.50.5160000.0FalseNoneNoneFalseNoneFalse80000.00
3430541121553Nonecode22Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A DPEach739.0739.06.0FalseNoneNoneFalseNoneFalse4434.00
3430509121553Nonecode231.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km178973.23178973.230.3FalseNoneNoneFalseNoneFalse53691.9690
3430542121553Nonecode23Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 A TPNEach3088.03088.08.0FalseNoneNoneFalseNoneFalse24704.00
3430510121553Nonecode241.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - HDPE pipe grade PE100-PN 10, 63mmMtr132.0132.0280.0FalseNoneNoneFalseNoneFalse36960.00
3430511121553Nonecode25Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - 35 to 95 SqmmKm31138.5431138.540.3FalseNoneNoneFalseNoneFalse9341.5620
3430512121553Nonecode26Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED SourceLED Streetlight 70WEach5992.05992.04.0FalseNoneNoneFalseNoneFalse23968.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17198422010000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17198422010000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17198422010000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17198422010000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17198422010000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17198422170000NoneNoneELIGIBILITYall terms and conditions are mentioned in tender documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNonesatisfactorily completion as prime Bidder, at least one similar work in last five years such as Construction of Building work of value not less than i.e. Rs. 85.00 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Upload Work Done Certificate with Break up Quantities
NoneNoneNoneNoneTenderer has to Submit the hard copies of all documents uploaded in KPPP Portal no other documents should be enclosed in the hard copies The hard copies to be submitted after closing of tender and before opening of Tender Only Technical documents to be givenCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Give Declaration stating that submitted the hard copies what we had uploaded in kppp portal only
NoneNoneNoneNonePAN CARDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN CARD
NoneNoneNoneNoneOWNED MACHINERIES OR EQUIPMENTS IN THE NAME OF CONTRACTOR OR COMPANY NAMECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tipper documents Such as RC Book, Tax , Insurance
NoneNoneNoneNoneOthers -- Self Loading Concrete Mixer with Weigh Batch/Transit mixer Documents Upload the Supporting documents
NoneNoneNoneNoneOthers -- Centering & Shuttering Materials Upload the Invoices if not available give the declaration stating that availability of the items
NoneNoneNoneNoneOthers -- Compressive testing machine upload relevant invoices
NoneNoneNoneNoneOthers -- Digital Weighing Machine (upto 50kg) Upload relevant invoices
NoneNoneNoneNoneOthers -- Digital Weighing Machine (upto 5 kg) Upload relevant invoices
NoneNoneNoneNoneOthers -- Coarse and fine aggregate sieve set (Each)
NoneNoneNoneNoneOthers -- Office and lab ( give the supporting documents as well as supporting documents for having own laboratory with photographs)
NoneNoneNoneNoneBID CAPACITY WITH DULLY ATTESTED BY THE TENDERERCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY WITH DULLY ATTESTED BY THE TENDERER
NoneNoneNoneNoneDECLARATION FOR NOT BLACKLISTING IN ANY OF THE GOVERNMENT DEPARTMENTCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- DECLARATION
NoneNoneNoneNoneDeclaration Stating that i had read and understood tender booklet and accepted for all your terms and conditionsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- self declaration
NoneNoneNoneNoneKPWD LICENSECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneDECLARATION STATING THAT If there is any forged documents found at the time of evaluation you can blacklist in the kppp portal. and EMD Can be forefittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- SELF DECLARATION
NoneNoneNoneNoneSECTION 4 FORMS OF TENDER LETTER OF ACCEPTANCE NOTICE TO PROCEED WITH THE WORK AND AGREEMENT FORMCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- TENDER FORMS WITH SEAL AND SIGNATURE
NoneNoneNoneNoneQUALIFICATION INFORMATIONCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- SECTION 3
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs.85.00 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneLEASED OR RENTED MACHINERY / EQUIPMENTS / INSTRUMENTSCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Excavator Hydraulic Excavator or Backhoe Loader Upload Agreement and all Vehichle Documents
NoneNoneNoneNoneOthers -- Tipper Upload Agreement and all Vehicle Documents
NoneNoneNoneNoneOthers -- Self Loading Concrete Mixer with Weigh Batch/Transit mixer Upload Agreement copy along with the supporting invoices
NoneNoneNoneNoneOthers -- Water Tanker Upload Agreement copy along with supporting documents
NoneNoneNoneNoneGST REGISTRATION CERTIFICATECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST REGISTRATION CERTIFICATE
NoneNoneNoneNoneAnnual Turnover certificate for 5 Years with UDIN No last five years i.e 2018 19 to 2022 23 FINANCIAL YEARFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonelast five years i.e. 2018-19 to 2023-24 upload ITR Acknowledgement copy profit and loss statement Balance sheet and all financials and should be attested by the CA with UDIN NoFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- COMPLETE ITR COPIES WITH AUDIT REPORTS
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719843622000
version0
createdDateNone
modifiedDateNone
blockNumberOFFICE OF MANAGING DIRECTOR KSTIDCL TRADE CENTRE 1ST FLOOR NEAR SUGAM TRAVELS RACE COURSE ROAD BANGALORE
streetNone
cityBANGALORE
stateKarnataka
pin560001
tenderRecallDTONone