createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719841727328
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd1500200.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-07-2024 16:00:00
tenderQueryClose25-07-2024 13:30:00
technicalBidOpen02-08-2024 11:00:00
publishedDate01-07-2024 19:39:57
publishedByPostKLBUDA_COM_HOD
publishedByUserKPE20214 - GANGADHAR S MALAGI
bidValidityPeriod180
noOfCalls1
preBidMeetingDate23-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonDileep Jadhav
splitEmdRequiredYnTrue
emdBankGuarantee1400200.00
emdCash100000.00
bgValidityPeriod240
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449172530
tenderSupplierListNone
tenderSchedule
createdTs1719841727363
version4
createdDateNone
modifiedDateNone
tenderNumberKLBUDA/2024-25/EL/WORK_INDENT10
titleEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi.
descriptionEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi.
categoryWORKS
categoryTextWorks
ecv150011194.49
deptNameKalaburagi Urban Development Authority
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1755
locationNameKLBUDA Commissioner Office Kalaburagi
provisionalAmount153082000.0
groupOverheadTotal22883064.0
fileNumberKUDA/DB/ABVP/SS/2024-25/891
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17198417270000NoneNoneElectricalEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi. (PART A STATION WORK)71406851.13
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3429862121537Nonecode01POWER TRANSFROMER: Supply of material cost: Power Transformer 10 MVA,110/11 kV Delta / Star, Dyn11, 3 Ph, 50 Hz, Core type winding with OLTC, RTCC panel, etc., complete filled with Transil oil with 10% spare oil with Terminal connectors suitable for Drake ACSR on 110 kV side and Drake ACSR/2 nos of 50 x 8 mm copper flat for each phase from LV side of Transformer to cable at 11 kV cable terminating structure with suitable support insulator on LV side of Transformer and 2 nos of 50mm x8mm copper flats from neutral terminal to earthmat through NCT along with necessary support pin insulators.(Tesla Make PTR weight -40.975MT & oil -15850ltrs)No.11719092.011719092.02.0FalseNoneNoneFalseNoneFalse23438184.00
3429863121537Nonecode02Errection charges : Power Transformer 10 MVA,110/11 kV Delta / Star, Dyn11, 3 Ph, 50 Hz, Core type winding with OLTC, RTCC panel, etc., complete filled with Transil oil with 10% spare oil with Terminal connectors suitable for Drake ACSR on 110 kV side and Drake ACSR/2 nos of 50 x 8 mm copper flat for each phase from LV side of Transformer to cable at 11 kV cable terminating structure with suitable support insulator on LV side of Transformer and 2 nos of 50mm x8mm copper flats from neutral terminal to earthmat through NCT along with necessary support pin insulators.(Tesla Make PTR weight -40.975MT & oil -15850ltrs)No.337381.43337381.432.0FalseNoneNoneFalseNoneFalse674762.860
3429864121537Nonecode03Testing and Commissioning charges :Power Transformer 10 MVA,110/11 kV Delta / Star, Dyn11, 3 Ph, 50 Hz, Core type winding with OLTC, RTCC panel, etc., complete filled with Transil oil with 10% spare oil with Terminal connectors suitable for Drake ACSR on 110 kV side and Drake ACSR/2 nos of 50 x 8 mm copper flat for each phase from LV side of Transformer to cable at 11 kV cable terminating structure with suitable support insulator on LV side of Transformer and 2 nos of 50mm x8mm copper flats from neutral terminal to earthmat through NCT along with necessary support pin insulators.(Tesla Make PTR weight -40.975MT & oil -15850ltrs)No.50596.3550596.352.0FalseNoneNoneFalseNoneFalse101192.70
3429865121537Nonecode04Nitrogen injection fire extinguishing system including civil Ewngineering works, soak pit etc. as per the recommendation of the supllier of the fire lighitng system for 110KV 10 MVA and above power transformerNo.1198716.751198716.752.0FalseNoneNoneFalseNoneFalse2397433.50
3429866121537Nonecode05CIRCUIT BREAKER: Material cost : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structure for 110/11 kV TransformerNo.738160.5738160.52.0FalseNoneNoneFalseNoneFalse1476321.00
3429867121537Nonecode06Errection charges : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structure.for 110/11 kV TransformerNo.11355.7511355.752.0FalseNoneNoneFalseNoneFalse22711.50
3429868121537Nonecode07Testing commission charges : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structure for 110/11 kV TransformerNo.48485.8548485.852.0FalseNoneNoneFalseNoneFalse96971.70
3429869121537Nonecode08Material cost of CIRCUIT BREAKER: SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structureFor 110 kV Trans.LineNo.738160.5738160.52.0FalseNoneNoneFalseNoneFalse1476321.00
3429870121537Nonecode09Errection charges of CIRCUIT BREAKER: SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structure. For 110 kV Trans.LineNo.11355.7511355.752.0FalseNoneNoneFalseNoneFalse22711.50
3429871121537Nonecode10Testing commission charges of CIRCUIT BREAKER: SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-meta11ic terminal connector suitable for Drake ACSR and mounting structure For 110 kV Trans.LineNo.48485.8548485.852.0FalseNoneNoneFalseNoneFalse96971.70
3429872121537Nonecode11ISOLATORS: Mateial cost of Isolators including marshalling box and suitable terminal connectors ,as required as per technical specification with solid core cylindrical post insulators ISOLATORS :110 kV, 1250 A, 31.5 KA class double break manually operated isolator with terminal connectors suitable for Drake ACSR/63mm A1.pipe. Upright mounting type with Earth switch LPH 4600mm terminal connectors suitable for Drake ACSRSet400207.5400207.52.0FalseNoneNoneFalseNoneFalse800415.00
3429873121537Nonecode12Errection charges :Upright mounting type with Earth switch LPH 4600mm terminal connectors suitable for Drake ACSRSet9136.059136.052.0FalseNoneNoneFalseNoneFalse18272.10
3429874121537Nonecode13Testing and commisionig charges:Upright mounting type with Earth switch LPH 4600mm terminal connectors suitable for Drake ACSRSet1366.051366.052.0FalseNoneNoneFalseNoneFalse2732.10
3429875121537Nonecode14ISOLATORS Material cost : Upright mounting type without Earth switch LPH 4600m for terminal connectors with 75mm Al.Pipe/Drake ACSR.Set337953.0337953.01.0FalseNoneNoneFalseNoneFalse337953.00
3429876121537Nonecode15Errection charges :Upright mounting type without Earth switch LPH 4600m for terminal connectors with 75mm Al.Pipe/Drake ACSR.Set9136.059136.051.0FalseNoneNoneFalseNoneFalse9136.050
3429877121537Nonecode16Testing and commisionig charges : Upright mounting type without Earth switch LPH 4600m for terminal connectors with 75mm Al.Pipe/Drake ACSR.Set1366.051366.051.0FalseNoneNoneFalseNoneFalse1366.050
3429878121537Nonecode17ISOLATORS Material cost :Upright mounting type without Earth switch LPH 6350m without earth switch terminal connectors with 63mm A1.Pipe/Drake ACSR.Set345576.0345576.04.0FalseNoneNoneFalseNoneFalse1382304.00
3429879121537Nonecode18Errection charges: Upright mounting type without Earth switch LPH 6350m without earth switch terminal connectors with 63mm A1.Pipe/Drake ACSR.Set9136.059136.054.0FalseNoneNoneFalseNoneFalse36544.20
3429880121537Nonecode19Testing and commisionig charges: Upright mounting type without Earth switch LPH 6350m without earth switch terminal connectors with 63mm A1.Pipe/Drake ACSR.Set1366.051366.054.0FalseNoneNoneFalseNoneFalse5464.20
3429881121537Nonecode20Material cost: 11 kV isolator, double break 400 A, 25 KA capacity with rigid bimetallic terminal connector suitable for coyote ACSR for feeders/Capacitor BankNo22323.022323.02.0FalseNoneNoneFalseNoneFalse44646.00
3429882121537Nonecode21Errection charges: 11 kV isolator, double break 400 A, 25 KA capacity with rigid bimetallic terminal connector suitable for coyote ACSR for feeders/Capacitor BankNo1274.71274.72.0FalseNoneNoneFalseNoneFalse2549.40
3429883121537Nonecode22Material cost: 110 KV isolator, single break 400A, 25KVA capacity with Roaster switch with rigid bimetallic terminal connector suitable for coyote ACSRSet15703.815703.811.0FalseNoneNoneFalseNoneFalse172741.80
3429884121537Nonecode23Errection charges: 110 KV isolator, single break 400A, 25KVA capacity with Roaster switch with rigid bimetallic terminal connector suitable for coyote ACSRSet1274.71274.711.0FalseNoneNoneFalseNoneFalse14021.70
3429885121537Nonecode24Material cost: CURRENT TRANSFORMER : Current transformers including marshalling boxes, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor: 110 kV class, 31.5 KA, CT of ratio 200-100/ 1-1-1lA for Transformers Core - 1 :Vk-400 V, Rct 2 ohm at 200/1A, Accuracy class Ps-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.141025.5141025.56.0FalseNoneNoneFalseNoneFalse846153.00
3429886121537Nonecode25Errection charges: 110 kV class, 31.5 KA, CT of ratio 200-100/ 1-1-1lA for Transformers Core - 1 :Vk-400 V, Rct 2 ohm at 200/1A, Accuracy class Ps-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.2237.552237.556.0FalseNoneNoneFalseNoneFalse13425.30
3429887121537Nonecode26Testing and commissionig charges: 110 kV class, 31.5 KA, CT of ratio 200-100/ 1-1-1lA for Transformers Core - 1 :Vk-400 V, Rct 2 ohm at 200/1A, Accuracy class Ps-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.4935.04935.06.0FalseNoneNoneFalseNoneFalse29610.00
3429888121537Nonecode27Material cost: 110 kV class, 31.5 KA, CT of ratio 400 -200/ 1-1-1lA for Tr.Lines Core - 1 : For differential/ distance protection: PS class.Vk-800V Rct 4 ohm at 400/1A Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.142296.0142296.06.0FalseNoneNoneFalseNoneFalse853776.00
3429889121537Nonecode28Errection charges: 110 kV class, 31.5 KA, CT of ratio 400 - 200/ 1-1-1lA for Tr.Lines Core - 1 : For differential/ distance protection: PS class.Vk-800V Rct 4 ohm at 400/1A Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.2237.552237.556.0FalseNoneNoneFalseNoneFalse13425.30
3429890121537Nonecode29Testing and commissionig charges: 110 kV class, 31.5 KA, CT of ratio 400 - 200/ 1-1-1lA for Tr.Lines Core - 1 : For differential/ distance protection: PS class.Vk-800V Rct 4 ohm at 400/1A Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back upNo.4935.04935.06.0FalseNoneNoneFalseNoneFalse29610.00
3429891121537Nonecode30Material cost: 11 kV class, 25 KA, NCT of ratio 1200-800/1-1A for REFR protection (similar rating and ratio as that of incomer of 11 kV Switchgear) with terminal connector suitable for 2 no's of 50 X8 mm Copper flatsNo.59713.559713.52.0FalseNoneNoneFalseNoneFalse119427.00
3429892121537Nonecode31Errection charges: 11 kV class, 25 KA, NCT of ratio 1200-800/1-1A for REFR protection (similar rating and ratio as that of incomer of 11 kV Switchgear) with terminal connector suitable for 2 no's of 50 X8 mm Copper flatsNo.769.65769.652.0FalseNoneNoneFalseNoneFalse1539.30
3429893121537Nonecode32Testing and commissionig charges: 11 kV class, 25 KA, NCT of ratio 1200-800/1-1A for REFR protection (similar rating and ratio as that of incomer of 11 kV Switchgear) with terminal connector suitable for 2 no's of 50 X8 mm Copper flatsNo.4772.254772.252.0FalseNoneNoneFalseNoneFalse9544.50
3429894121537Nonecode33VOLTAGE TRANSFORMER : Material cost : Single phase, oil filled outdoor type including Marshaling KIOSK with rigid bimetallic terminal connectors suitable for drake ACSR.110 kV class 110kV/RT3/110V/RT3/ 110V/RT3/110V/RT3 Core -1 : 300 VA, Accuracy class 3P. Protection Core - 2 : 200 VA, Accuracy class 0.2s. Metering Core - 3 : 50 VA, Accuracy class 3P. Open delta ProtectionNo.157542.0157542.03.0FalseNoneNoneFalseNoneFalse472626.00
3429895121537Nonecode34Errection charges: 110 kV class 110kV/RT3/110V/RT3/ 110V/RT3/110V/RT3 Core -1 : 300 VA, Accuracy class 3P. Protection Core - 2 : 200 VA, Accuracy class 0.2s. Metering Core - 3 : 50 VA, Accuracy class 3P. Open delta ProtectionNo.2237.552237.553.0FalseNoneNoneFalseNoneFalse6712.650
3429896121537Nonecode35Testing & Commissioning charges : 110 kV class 110kV/RT3/110V/RT3/ 110V/RT3/110V/RT3 Core -1 : 300 VA, Accuracy class 3P. Protection Core - 2 : 200 VA, Accuracy class 0.2s. Metering Core - 3 : 50 VA, Accuracy class 3P. Open delta ProtectionNo.4968.64968.63.0FalseNoneNoneFalseNoneFalse14905.80
3429897121537Nonecode36a) Material cost:Surge Arrestors: (Procelain housing) metal oxide, Gapless type with rigid bimetallic connectors suitable for Drake ACSR 96 kV, 10 KA, class - II, Normal duty Metal oxide typeNo.43197.043197.012.0FalseNoneNoneFalseNoneFalse518364.00
3429898121537Nonecode37Errection charges: 96 kV, 10 KA, class - II, Normal duty Metal oxide typeNo.466.2466.212.0FalseNoneNoneFalseNoneFalse5594.40
3429899121537Nonecode38Material cost: kV, 10 KA with connector and clampNo.966.0966.033.0FalseNoneNoneFalseNoneFalse31878.00
3429900121537Nonecode39Errection charges: 9 kV, 10 KA with connector and clampNo.40.9540.9533.0FalseNoneNoneFalseNoneFalse1351.350
3429901121537Nonecode40Material cost: Capacitor Bank : Design engineering, supply,erection (including civil works) Testing and commissioning of 12.1KV, 2.9MVAR capacitor Bank, star connected, doub1e bank with internal fuses, Terminal connectors, with suitable neutral CT and station class LA's, 0.2% series reactor on neutral side with mounting structure for NCT, capacitor Bank station class LA's series Reactor etc., complete as per specification (including testing commissioning) Note:11kv Switchgear and remote annunciation/control of the capacitor Bank is included in item No.A18Set565372.5565372.52.0FalseNoneNoneFalseNoneFalse1130745.00
3429902121537Nonecode41Material cost of Control & Protection Panels Simplex type:110/11 kV Transformer panel TypeNo.663201.0663201.02.0FalseNoneNoneFalseNoneFalse1326402.00
3429903121537Nonecode42Errection charges of 110/11 kV Transformer panel TypeNo.6256.956256.952.0FalseNoneNoneFalseNoneFalse12513.90
3429904121537Nonecode43Testing and commissionig charges of 110/11 kV Transformer panel TypeNo.36385.6536385.652.0FalseNoneNoneFalseNoneFalse72771.30
3429905121537Nonecode44Material cost of For 110KV Transmission lineNo.478978.5478978.52.0FalseNoneNoneFalseNoneFalse957957.00
3429906121537Nonecode45Errection charges of For 110KV Transmission lineNo.6256.956256.952.0FalseNoneNoneFalseNoneFalse12513.90
3429907121537Nonecode46Testing and commissionig charges of For 110KV Transmission lineNo.36385.6536385.652.0FalseNoneNoneFalseNoneFalse72771.30
3429908121537Nonecode47Material cost : STATION STRUCTURES :110 kV Station Structure fabricated out of galvanised iron. Column type 21T1 with peak. (0.952 MT per tower)No135801.2135801.23.0FalseNoneNoneFalseNoneFalse407403.60
3429909121537Nonecode48Errection charges: 110 kV Station Structure fabricated out of galvanised iron. Column type 21T1 with peak. (0.952 MT per tower)No6009.156009.153.0FalseNoneNoneFalseNoneFalse18027.450
3429910121537Nonecode49Material cost:110 kV Station structure fabricated out of galvanised iron. Beam type 21B1 without underhung isolator.(0.465, MT per tower)No66442.0766442.072.0FalseNoneNoneFalseNoneFalse132884.140
3429911121537Nonecode50Errection charges: 110 kV Station structure fabricated out of galvanised iron. Beam type 21B1 without underhung isolator.(0.465, MT per tower)No6009.156009.152.0FalseNoneNoneFalseNoneFalse12018.30
3429912121537Nonecode5111 KV ODS and take off structure: Material cost : Supply and erection of D.P. Structure with all accessories using 9.0mtr long, 145 Kg WL suitable for mounting roaster GOS/Capacitor BankNos27360.927360.913.0FalseNoneNoneFalseNoneFalse355691.70
3429913121537Nonecode52Errection charges: Supply and erection of D.P. Structure with all accessories using 9.0mtr long, 145 Kg WL suitable for mounting roaster GOS/Capacitor BankNos3358.953358.9513.0FalseNoneNoneFalseNoneFalse43666.350
3429914121537Nonecode53Material cost: Supply and erection of D.P. Structure with all accessories for Auxiliary transformerNos9306.159306.151.0FalseNoneNoneFalseNoneFalse9306.150
3429915121537Nonecode54Errection charges: Supply and erection of D.P. Structure with all accessories for Auxiliary transformerNos6261.156261.151.0FalseNoneNoneFalseNoneFalse6261.150
3429916121537Nonecode55MOUNTING STRUCTURES : Material cost: 110 kV Isolators. (0.741 MT er structure) LPH 4600mmNo105555.68105555.683.0FalseNoneNoneFalseNoneFalse316667.040
3429917121537Nonecode56Errection charges :10 kV Isolators. (0.741 MT er structure) LPH 4600mmNo6009.156009.153.0FalseNoneNoneFalseNoneFalse18027.450
3429918121537Nonecode57Material cost:110 kV Isolators. (0.924 MT per structure) LPH 6350mmNo131710.19131710.194.0FalseNoneNoneFalseNoneFalse526840.760
3429919121537Nonecode58Errection charges:110 kV Isolators. (0.924 MT per structure) LPH 6350mmNo6009.156009.154.0FalseNoneNoneFalseNoneFalse24036.60
3429920121537Nonecode59Material cost: Current transformer. 110 kV & 11KV NCT (0.152 MT per structure)No21720.4721720.4712.0FalseNoneNoneFalseNoneFalse260645.640
3429921121537Nonecode60Errection charges: Current transformer. 110 kV & 11KV NCT (0.152 MT per structure)No6009.156009.1512.0FalseNoneNoneFalseNoneFalse72109.80
3429922121537Nonecode61Material cost: Voltage transformer. 110 kV . (0.142 MT per structure)No20289.8920289.893.0FalseNoneNoneFalseNoneFalse60869.670
3429923121537Nonecode62Errection charges: Voltage transformer. 110 kV . (0.142 MT per structure)No6009.156009.153.0FalseNoneNoneFalseNoneFalse18027.450
3429924121537Nonecode63Material cost: Lightening arrestors. 110 kV . (0.111 MT per structure)No15878.7115878.7112.0FalseNoneNoneFalseNoneFalse190544.520
3429925121537Nonecode64Errection charges: Lightening arrestors. 110 kV . (0.111 MT per structure)No6009.156009.1512.0FalseNoneNoneFalseNoneFalse72109.80
3429926121537Nonecode65Material cost: Pedestal insulators. 110 kV . (0.141 MT per structure) for BusNo20155.2120155.218.0FalseNoneNoneFalseNoneFalse161241.680
3429927121537Nonecode66Errection charges: Pedestal insulators. 110 kV . (0.141 MT per structure) for BusNo6009.156009.158.0FalseNoneNoneFalseNoneFalse48073.20
3429928121537Nonecode67Material cost: Hight predestal insulators for 110 kv side (0.218 MT per sturcture)No31150.1231150.126.0FalseNoneNoneFalseNoneFalse186900.720
3429929121537Nonecode68Errection charges: Hight predestal insulators for 110 kv side (0.218 MT per sturcture)No6009.156009.156.0FalseNoneNoneFalseNoneFalse36054.90
3429930121537Nonecode69Material cost: 11 kV Cable terminating structure for LV side of Transformer. (0.072 MT per power)No6303.156303.152.0FalseNoneNoneFalseNoneFalse12606.30
3429931121537Nonecode70Errection charges: 11 kV Cable terminating structure for LV side of Transformer. (0.072 MT per power)No6009.156009.152.0FalseNoneNoneFalseNoneFalse12018.30
3429932121537Nonecode71BUS BAR FORMATION : Material cost: Drake ACSRMtr406.35406.35300.0FalseNoneNoneFalseNoneFalse121905.00
3429933121537Nonecode72AAAC MooseMtr579.6579.6150.0FalseNoneNoneFalseNoneFalse86940.00
3429934121537Nonecode73Coyote ACSR (llKV Side )Mtr145.95145.9530.0FalseNoneNoneFalseNoneFalse4378.50
3429935121537Nonecode747/3.15 mm Ground wireMtr92.492.4150.0FalseNoneNoneFalseNoneFalse13860.00
3429936121537Nonecode75BUS BAR FORMATION : Errection charges: Formation of Main/Cross bus on 110 kV sideNo12691.3512691.353.0FalseNoneNoneFalseNoneFalse38074.050
3429937121537Nonecode76Faraday cage formation as per specification for 110KV -Approx rate consideredNo2625.02625.02.0FalseNoneNoneFalseNoneFalse5250.00
3429938121537Nonecode77Supply and Erection of rigid bus with taps and clamps (Material cost) Aluminium tube conforming to 6340WP of IS -5082/l969 (BS 1600-Sch.40) of following nominal diameter a)75mm - 110KV Main Bus.Mtr1665.31665.342.0FalseNoneNoneFalseNoneFalse69942.60
3429939121537Nonecode78b)63mm size connecting isolator to vertical tap and also connecting equipments to equipments -110KV side. Mtr1524.61524.672.0FalseNoneNoneFalseNoneFalse109771.20
3429940121537Nonecode79Straight taps suitable for 63mm Aluminium tube (BS-1600) of 1750mm vertical height for vertical portion & cross bus on 110KV side with rounded off end.Nos3922.83922.86.0FalseNoneNoneFalseNoneFalse23536.80
3429941121537Nonecode80Post insulator clamps suitable for 63 mm Aluminium pipe & Post insulator solid core type - 110kV side a)Rigid TypeNos1840.651840.653.0FalseNoneNoneFalseNoneFalse5521.950
3429942121537Nonecode81Sliding TypeNos1555.051555.055.0FalseNoneNoneFalseNoneFalse7775.250
3429943121537Nonecode82Corona Bell Suitable for Aluminium Pipe of size 75mm on 110kV side.(BS 1600)Nos712.95712.953.0FalseNoneNoneFalseNoneFalse2138.850
3429944121537Nonecode83Flexible type terminal conector suitable for 75m‘' Main bus Aluminium pipe to connect Bus PTNos1840.651840.653.0FalseNoneNoneFalseNoneFalse5521.950
3429945121537Nonecode84Flexible type terminal conector suitable for 63 mm Aluminium pipe to connect Bus isolatorNos4113.94113.912.0FalseNoneNoneFalseNoneFalse49366.80
3429946121537Nonecode85Rigid type terminall connector for Drake ACSR to isolatorNos2570.42570.427.0FalseNoneNoneFalseNoneFalse69400.80
3429947121537Nonecode86End cap suitable for 63mm Aluminium tubeNos716.1716.13.0FalseNoneNoneFalseNoneFalse2148.30
3429948121537Nonecode87INSULATORS : Material cost: Post insulator Cylindrical Solid core Insulator 110 kV,1 Unit/stackNo12657.7512657.7514.0FalseNoneNoneFalseNoneFalse177208.50
3429949121537Nonecode88Errection charges: Post insulator Cylindrical Solid core Insulator 110 kV,1 Unit/stackNo466.2466.214.0FalseNoneNoneFalseNoneFalse6526.80
3429950121537Nonecode89Single tension string 90KN, 9 units of each along with bolted type tension clamp and hardware suitable for Drake ACSR (110KV)No8151.158151.156.0FalseNoneNoneFalseNoneFalse48906.90
3429951121537Nonecode90Single tension string 90KN, 9 units of each along with bolted type tension clamp and hardware suitable for Drake ACSR (110KV)No7203.07203.03.0FalseNoneNoneFalseNoneFalse21609.00
3429952121537Nonecode91HARDWARES : C type wedge connector suitable for Lynx-Dake(110 kV line side)No2017.052017.0512.0FalseNoneNoneFalseNoneFalse24204.60
3429953121537Nonecode92Post Insulator clamp suitable for 75mm A1.Tube/ Single Drake ACSR and 110 kV Solid Core InsulatorNo1060.51060.514.0FalseNoneNoneFalseNoneFalse14847.00
3429954121537Nonecode93Auxiliary Transformer: Material cost : Supply and erection of Station Auxiliary Transformer with oil, outdoor type, 100 kVA, 11 kV/433 V, 3 Ph, Vector group Dyn 11 off load tap changer(5 taps) with step voltage of 2.5% along with DOLO/HG-fuse imit, LT protection kit, Distribution box and other accessories as per specification.No366655.8366655.81.0FalseNoneNoneFalseNoneFalse366655.80
3429955121537Nonecode94Errection charges: Supply and erection of Station Auxiliary Transformer with oil, outdoor type, 100 kVA, 11 kV/433 V, 3 Ph, Vector group Dyn 11 off load tap changer(5 taps) with step voltage of 2.5% along with DOLO/HG-fuse imit, LT protection kit, Distribution box and other accessories as per specification.No19521.619521.61.0FalseNoneNoneFalseNoneFalse19521.60
3429956121537Nonecode95Material cost: LTAC Distribution panel ( Indoor) comprising cif 415 Volt meter, Ammeter & 1 no of ETV meter, 1 I/C MCCB 200A + 2 nos 3 phase, 63A OG HRC fuse + 2 nos 3 phase 32A OG HRC fuse + 6 nos 3 phase 16A HRC fuse etec complete with all necessary protection as per technical specification 415 V.No90205.590205.51.0FalseNoneNoneFalseNoneFalse90205.50
3429957121537Nonecode96Errection charges: LTAC Distribution panel ( Indoor) comprising cif 415 Volt meter, Ammeter & 1 no of ETV meter, 1 I/C MCCB 200A + 2 nos 3 phase, 63A OG HRC fuse + 2 nos 3 phase 32A OG HRC fuse + 6 nos 3 phase 16A HRC fuse etec complete with all necessary protection as per technical specification 415 V.No3367.353367.351.0FalseNoneNoneFalseNoneFalse3367.350
3429958121537Nonecode97Material cost: AC Distribution box (outdoor) Single front type with 6 terminals 1200 x 1350 x 300 mm one I/C of 100 A MCCB 20 KA+ 6 O/G 16 A MCB +1 O/G of 100 A HRC Fuse panel 415 V outdoor typeNo76230.076230.01.0FalseNoneNoneFalseNoneFalse76230.00
3429959121537Nonecode98Errection charges: AC Distribution box (outdoor) Single front type with 6 terminals 1200 x 1350 x 300 mm one I/C of 100 A MCCB 20 KA+ 6 O/G 16 A MCB +1 O/G of 100 A HRC Fuse panel 415 V outdoor typeNo2589.32589.31.0FalseNoneNoneFalseNoneFalse2589.30
3429960121537Nonecode99Material cost: LT Power armoured UG cable as per specification: Material cost:1.1kV grade PVC Insulated armoured Aluminium cable 4c x 95 Sq.mmMtr800.1800.1100.0FalseNoneNoneFalseNoneFalse80010.00
3429961121537Nonecode100Errection charges: 1.1kV grade PVC Insulated armoured Aluminium cable 4c x 95 Sq.mmMtr15.7515.75100.0FalseNoneNoneFalseNoneFalse1575.00
3429962121537Nonecode101Material cost:: 1.1kV grade PVC Insulated armoured Copper cables 4c x 25 Sq.mmMtr909.3909.3150.0FalseNoneNoneFalseNoneFalse136395.00
3429963121537Nonecode102Errection charges: 1.1kV grade PVC Insulated armoured Copper cables 4c x 25 Sq.mmMtr15.7515.75150.0FalseNoneNoneFalseNoneFalse2362.50
3429964121537Nonecode103Material cost: 1.1kV grade PVC Insulated armoured Copper cables 4c x 10 Sq.mmMtr393.75393.75200.0FalseNoneNoneFalseNoneFalse78750.00
3429965121537Nonecode104Errection charges: 1.1kV grade PVC Insulated armoured Copper cables 4c x 10 Sq.mmMtr15.7515.75200.0FalseNoneNoneFalseNoneFalse3150.00
3429966121537Nonecode105STATION BATTERY & BATTERY CHARGER : Material cost: 110 V, 100 AH, Battery set consisting of 55 No cells with accessories as per specificationSet633979.5633979.51.0FalseNoneNoneFalseNoneFalse633979.50
3429967121537Nonecode106Errection charges: 110 V, 100 AH, Battery set consisting of 55 No cells with accessories as per specificationSet12202.0512202.051.0FalseNoneNoneFalseNoneFalse12202.050
3429968121537Nonecode107Material cost: Battery charger suitable for '1 X 110 V, 100 AH, Battery set consisting of 55 No cells with float cum booster type battery charger as per specificationSet177870.0177870.01.0FalseNoneNoneFalseNoneFalse177870.00
3429969121537Nonecode108Errection charges: Battery charger suitable for '1 X 110 V, 100 AH, Battery set consisting of 55 No cells with float cum booster type battery charger as per specificationSet1204.351204.351.0FalseNoneNoneFalseNoneFalse1204.350
3429970121537Nonecode109Material cost: DC Distribution panel ( Indoor) as per Technical specification comprising of Earth fault indicator, Indication circuit for AC main failure, 1 no 100A SFU for IC + 12 Nos, 32A SFU for OG etc,. complete.No54631.554631.51.0FalseNoneNoneFalseNoneFalse54631.50
3429971121537Nonecode110Errection charges: DC Distribution panel ( Indoor) as per Technical specification comprising of Earth fault indicator, Indication circuit for AC main failure, 1 no 100A SFU for IC + 12 Nos, 32A SFU for OG etc,. complete.No2589.32589.31.0FalseNoneNoneFalseNoneFalse2589.30
3429972121537Nonecode111Copper Control Cabvles :1.1kV Grade PVC Insulated armoured copper control cables of sizes,with Lugs/Ferrules/ Gland as per technical specifications: Material cost:19c x 2.5 Sq.mmMtr551.25551.252000.0FalseNoneNoneFalseNoneFalse1102500.00
3429973121537Nonecode112Errection charges:19c x 2.5 Sq.mmMtr15.7515.752000.0FalseNoneNoneFalseNoneFalse31500.00
3429974121537Nonecode113Material cost:4c x 6 Sq.mmMtr259.35259.352200.0FalseNoneNoneFalseNoneFalse570570.00
3429975121537Nonecode114Errection charges: 4c x 6 Sq.mmMtr15.7515.752200.0FalseNoneNoneFalseNoneFalse34650.00
3429976121537Nonecode115Material cost: 4c x 2.5 Sq.mmMtr149.1149.11500.0FalseNoneNoneFalseNoneFalse223650.00
3429977121537Nonecode116Errection charges: 4c x 2.5 Sq.mmMtr15.7515.751500.0FalseNoneNoneFalseNoneFalse23625.00
3429978121537Nonecode117Material cost: 2c x 6 Sq.mmMtr161.7161.71500.0FalseNoneNoneFalseNoneFalse242550.00
3429979121537Nonecode118Errection charges: 2c x 6 Sq.mmMtr15.7515.751500.0FalseNoneNoneFalseNoneFalse23625.00
3429980121537Nonecode119Material cost: 2cx2.5 Sq.mmMtr98.798.7500.0FalseNoneNoneFalseNoneFalse49350.00
3429981121537Nonecode120Errection charges: 2cx2.5 Sq.mmMtr15.7515.75500.0FalseNoneNoneFalseNoneFalse7875.00
3429982121537Nonecode121Switchgear: Material cost : Switchgear 11kV,25KA, 500MVA Metal clad VCB Switchgear (1600A for Incomer and 1250A for feeders), outdoor type, each comprising of 2IC+12F+2CB+1BC+1AP (Remote Annouciation cum control pane) with CT's & PT's etc, complete as per technical specification. with erection at complete switchgear.Set16235719.516235719.51.0FalseNoneNoneFalseNoneFalse16235719.50
3429983121537Nonecode122Testing and commissioning charges: Switchgear 11kV,25KA, 500MVA Metal clad VCB Switchgear (1600A for Incomer and 1250A for feeders), outdoor type, each comprising of 2IC+12F+2CB+1BC+1AP (Remote Annouciation cum control pane) with CT's & PT's etc, complete as per technical specification. with erection at complete switchgear.Set120840.3120840.31.0FalseNoneNoneFalseNoneFalse120840.30
3429984121537Nonecode12311 KV UG cable with required cable termination kits at both ends: Material cost : a) One run of 11KV class 3 coreX 95 sq mm XLPE cable (to be run for Auxiliary transformers from 11KV switch gear to Auxiliary transformer)Mtr934.15934.1550.0FalseNoneNoneFalseNoneFalse46707.50
3429985121537Nonecode124Errection charges: One run of 11KV class 3 coreX 95 sq mm XLPE cable (to be run for Auxiliary transformers from 11KV switch gear to Auxiliary transformer)Mtr75.675.650.0FalseNoneNoneFalseNoneFalse3780.00
3429986121537Nonecode125Material cost : 11KV XLPE cable,1000sq mm Aluminium cable from 110/11KV Transformer to 11KV switch gearMtr1244.251244.25350.0FalseNoneNoneFalseNoneFalse435487.50
3429987121537Nonecode126Errection charges :11KV XLPE cable,1000sq mm Aluminium cable from 110/11KV Transformer to 11KV switch gearMtr75.675.6350.0FalseNoneNoneFalseNoneFalse26460.00
3429988121537Nonecode127Material cost : 11KV XLPE cable ,240sq mm Aluminium cable from 3 core to run from Switch gear to 11KV take off DP structure.Mtr1738.851738.85200.0FalseNoneNoneFalseNoneFalse347770.00
3429989121537Nonecode128Errection charges :11KV XLPE cable ,240sq mm Aluminium cable from 3 core to run from Switch gear to 11KV take off DP structure.Mtr75.675.6200.0FalseNoneNoneFalseNoneFalse15120.00
3429990121537Nonecode129Cable termination kit for 3coreX95 sq mm as per technical specification: Material cost: Indoor:Nos3931.23931.21.0FalseNoneNoneFalseNoneFalse3931.20
3429991121537Nonecode130Errection charges: Indoor:Nos3939.63939.61.0FalseNoneNoneFalseNoneFalse3939.60
3429992121537Nonecode131Material cost: Outdoor:Nos4270.354270.351.0FalseNoneNoneFalseNoneFalse4270.350
3429993121537Nonecode132Errection charges: Outdoor:Nos3939.63939.61.0FalseNoneNoneFalseNoneFalse3939.60
3429994121537Nonecode133l000sq mm sing1e core: Material cost:IndoorNos3998.43998.48.0FalseNoneNoneFalseNoneFalse31987.20
3429995121537Nonecode134Errection charges: IndoorNos3939.63939.68.0FalseNoneNoneFalseNoneFalse31516.80
3429996121537Nonecode135Material cost: OutdoorNos4263.04263.08.0FalseNoneNoneFalseNoneFalse34104.00
3429997121537Nonecode136Errection charges: OutdoorNos3939.63939.68.0FalseNoneNoneFalseNoneFalse31516.80
3429998121537Nonecode137240.00 sq mm 3 core: Material cost: IndoorNos4925.554925.5513.0FalseNoneNoneFalseNoneFalse64032.150
3429999121537Nonecode138Errection charges: IndoorNos3939.63939.613.0FalseNoneNoneFalseNoneFalse51214.80
3430000121537Nonecode139Material cost: OutdoorNos5583.95583.913.0FalseNoneNoneFalseNoneFalse72590.70
3430001121537Nonecode140Errection charges: OutdoorNos3939.63939.613.0FalseNoneNoneFalseNoneFalse51214.80
3430002121537Nonecode141Material cost: FIRE FIGHTING EQUIPMENTS WITH NECESSARY MOUNTING STANDS : Foam type extinguisher (Mechanical) 50 Ltr. capacityNo10617.610617.64.0FalseNoneNoneFalseNoneFalse42470.40
3430003121537Nonecode142Foam type extinguisher (Mechanical) 9 Ltr. capacityNo4323.94323.94.0FalseNoneNoneFalseNoneFalse17295.60
3430004121537Nonecode143Water type (gas pressure type) 9 Ltr. capacityNo2628.152628.156.0FalseNoneNoneFalseNoneFalse15768.90
3430005121537Nonecode144Carbon di-oxide type 4.5 kg CapaciyNo9125.559125.556.0FalseNoneNoneFalseNoneFalse54753.30
3430006121537Nonecode145Sand type G.I Buckets 15 Ltr. CapacityNo633.15633.1512.0FalseNoneNoneFalseNoneFalse7597.80
3430007121537Nonecode145Steel stands for above to have 4 buckets to each stand.No2480.12480.13.0FalseNoneNoneFalseNoneFalse7440.30
3430008121537Nonecode146Material cost: Maintenance Tools and Plant: Portable (mobile) oil pumps (1/2 HP air pump 500 - 1000 gallons)No21259.3521259.351.0FalseNoneNoneFalseNoneFalse21259.350
3430009121537Nonecode147Telescopic ladder Aluminium 6 Mtr. HeightNo23753.123753.11.0FalseNoneNoneFalseNoneFalse23753.10
3430010121537Nonecode148Ring spanner setSet924.0924.01.0FalseNoneNoneFalseNoneFalse924.00
3430011121537Nonecode149Tube spanner setSet1506.751506.751.0FalseNoneNoneFalseNoneFalse1506.750
3430012121537Nonecode150Pipe wrench 24 inchNos1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
3430013121537Nonecode151Pipe wrench 18 inch.Nos726.6726.62.0FalseNoneNoneFalseNoneFalse1453.20
3430014121537Nonecode152Hydraulic crimping tools up to 1000 Sq.mmNo65113.6565113.651.0FalseNoneNoneFalseNoneFalse65113.650
3430015121537Nonecode153Rubber hand gloves (15 kV tested)Pairs307.65307.653.0FalseNoneNoneFalseNoneFalse922.950
3430016121537Nonecode154Rechargable 5W LED hand torchNos1342.951342.954.0FalseNoneNoneFalseNoneFalse5371.80
3430017121537Nonecode155Insulated cutting plier 12 inch sizeNos412.65412.653.0FalseNoneNoneFalseNoneFalse1237.950
3430018121537Nonecode156Insulated cutting plier 8 inch sizeNos247.8247.83.0FalseNoneNoneFalseNoneFalse743.40
3430019121537Nonecode157Line live tester AC/DC 500 VNos326.55326.552.0FalseNoneNoneFalseNoneFalse653.10
3430020121537Nonecode158Screw driver 18"Nos234.15234.153.0FalseNoneNoneFalseNoneFalse702.450
3430021121537Nonecode159Screw driver 12"Nos78.7578.753.0FalseNoneNoneFalseNoneFalse236.250
3430022121537Nonecode160Hammer 8 lbsNos521.85521.852.0FalseNoneNoneFalseNoneFalse1043.70
3430023121537Nonecode161Hammer 2 lbsNos261.45261.452.0FalseNoneNoneFalseNoneFalse522.90
3430024121537Nonecode162Chain pulley block 5 ton capacityNos43927.843927.81.0FalseNoneNoneFalseNoneFalse43927.80
3430025121537Nonecode163Hydraulic jack 5T capacityNo7400.47400.44.0FalseNoneNoneFalseNoneFalse29601.60
3430026121537Nonecode164Pipe derrick suitable for lifting 3 MT and lift of 6 Mtr. height.Nos29222.5529222.551.0FalseNoneNoneFalseNoneFalse29222.550
3430027121537Nonecode165Allen keysSet501.9501.91.0FalseNoneNoneFalseNoneFalse501.90
3430028121537Nonecode166Box spannersSet4690.354690.351.0FalseNoneNoneFalseNoneFalse4690.350
3430029121537Nonecode167Transil oil di-electric break down (with 2.5 mm gap 0-60 kV) Tester.No106611.75106611.751.0FalseNoneNoneFalseNoneFalse106611.750
3430030121537Nonecode168Insulation megger 2.5 - 5 kVNo58073.458073.41.0FalseNoneNoneFalseNoneFalse58073.40
3430031121537Nonecode169Insulation megger 500 VNo18486.318486.31.0FalseNoneNoneFalseNoneFalse18486.30
3430032121537Nonecode170Multimeter electrornechanicalNo3857.73857.71.0FalseNoneNoneFalseNoneFalse3857.70
3430033121537Nonecode171Multimeter ElectronicNo8390.558390.551.0FalseNoneNoneFalseNoneFalse8390.550
3430034121537Nonecode172HydrometerNo690.9690.91.0FalseNoneNoneFalseNoneFalse690.90
3430035121537Nonecode173DC Voltmeter range -5V to + 5VNo2835.02835.01.0FalseNoneNoneFalseNoneFalse2835.00
3430036121537Nonecode174Hydrometer syringe suitable for vent holesNo945.0945.01.0FalseNoneNoneFalseNoneFalse945.00
3430037121537Nonecode175Specific gravity correction chartNo945.0945.01.0FalseNoneNoneFalseNoneFalse945.00
3430038121537Nonecode176Thermometer with wall mounting holderNo2835.02835.01.0FalseNoneNoneFalseNoneFalse2835.00
3430039121537Nonecode177Rubber appronNo2007.62007.61.0FalseNoneNoneFalseNoneFalse2007.60
3430040121537Nonecode178PippetteNos827.4827.41.0FalseNoneNoneFalseNoneFalse827.40
3430041121537Nonecode179Protective goggleNos945.0945.01.0FalseNoneNoneFalseNoneFalse945.00
3430042121537Nonecode180Acid resisting jars (4 pint capacity)Nos945.0945.01.0FalseNoneNoneFalseNoneFalse945.00
3430043121537Nonecode181Glass funnelNos709.8709.82.0FalseNoneNoneFalseNoneFalse1419.60
3430044121537Nonecode182Grounding sticksNos1842.751842.756.0FalseNoneNoneFalseNoneFalse11056.50
3430045121537Nonecode183Hickery rodsNos5668.955668.956.0FalseNoneNoneFalseNoneFalse34013.70
3430046121537Nonecode184Manila rope 1"Mtr7003.57003.5100.0FalseNoneNoneFalseNoneFalse700350.00
3430047121537Nonecode185Manila rope 3/4"Mtr4129.654129.65100.0FalseNoneNoneFalseNoneFalse412965.00
3430048121537Nonecode186Files of sizesNo9094.059094.056.0FalseNoneNoneFalseNoneFalse54564.30
3430049121537Nonecode187Saftey beltsNo1062.61062.62.0FalseNoneNoneFalseNoneFalse2125.20
3430050121537Nonecode188Saftey HelmetsNo289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3430051121537Nonecode189Steel measurmg tape 30 metersNo796.95796.951.0FalseNoneNoneFalseNoneFalse796.950
3430052121537Nonecode190Steel measuring tape 15 metersNo577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3430053121537Nonecode191Rain coat with Dick backNo1180.21180.22.0FalseNoneNoneFalseNoneFalse2360.40
3430054121537Nonecode192SF-6 gas leak DetectorNo68504.168504.11.0FalseNoneNoneFalseNoneFalse68504.10
3430055121537Nonecode193Wall mounting type holder for hydrometerNo2835.02835.01.0FalseNoneNoneFalseNoneFalse2835.00
3430056121537Nonecode194Rubber shoes knee heightPairs2244.92244.92.0FalseNoneNoneFalseNoneFalse4489.80
3430057121537Nonecode195Material cost: MISCELLANOUS ITEMS: Rubber mats 2000 mm x 1000 mm x 12 mm size suitable for 1.1 kV class.No3150.03150.04.0FalseNoneNoneFalseNoneFalse12600.00
3430058121537Nonecode196First aid box.No525.0525.01.0FalseNoneNoneFalseNoneFalse525.00
3430059121537Nonecode197Shock treatment chart:s, hard board, liminated with coloured pictures & literature both in Kannada & English.No2100.02100.01.0FalseNoneNoneFalseNoneFalse2100.00
3430060121537Nonecode198Water filter / Water purifies : Wall mounting type (Aqua-guard type).No18900.018900.01.0FalseNoneNoneFalseNoneFalse18900.00
3430061121537Nonecode199Sub-station name board duly painted.No10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
3430062121537Nonecode200Fixograph of size l.5m x 2.5m with English/Kannada alphabets.Set5460.05460.01.0FalseNoneNoneFalseNoneFalse5460.00
3430063121537Nonecode201Door locks 7 levers (Navtal make)No525.0525.05.0FalseNoneNoneFalseNoneFalse2625.00
3430064121537Nonecode202Danger board(prohibited) with support structure including fixing in front of the gateNo2100.02100.01.0FalseNoneNoneFalseNoneFalse2100.00
3430065121537Nonecode203Equipment name plates and earthing name plates including fixing at outdoor yardLS10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
3430066121537Nonecode204Material cost: Furniture for Control Room Staff and maintenance: Steel Almirahs 6 1/2 feetNos10500.010500.02.0FalseNoneNoneFalseNoneFalse21000.00
3430067121537Nonecode205Steel Almirahs 6 1/2 feet with glass panel doorsNos8400.08400.01.0FalseNoneNoneFalseNoneFalse8400.00
3430068121537Nonecode206Officers tablesNos9450.09450.02.0FalseNoneNoneFalseNoneFalse18900.00
3430069121537Nonecode207Steel Slotted angle rack (big size)Nos2625.02625.04.0FalseNoneNoneFalseNoneFalse10500.00
3430070121537Nonecode208Steel Slotted angle rack (small Size)Nos2100.02100.04.0FalseNoneNoneFalseNoneFalse8400.00
3430071121537Nonecode209Steel dustbinsNos420.0420.04.0FalseNoneNoneFalseNoneFalse1680.00
3430072121537Nonecode210Executive revolving chairsNos8400.08400.02.0FalseNoneNoneFalseNoneFalse16800.00
3430073121537Nonecode211S Type Arm ChairsNos1575.01575.06.0FalseNoneNoneFalseNoneFalse9450.00
3430074121537Nonecode212Steel folding ChairsNos525.0525.04.0FalseNoneNoneFalseNoneFalse2100.00
3430075121537Nonecode213Material cost: Equipments for establishing SCADA communication : Remote Terminal Unit (RTU)Nos1035457.51035457.51.0FalseNoneNoneFalseNoneFalse1035457.50
3430076121537Nonecode214Data Concentrator Unit DCU)Nos39385.539385.51.0FalseNoneNoneFalseNoneFalse39385.50
3430077121537Nonecode2152 kVA online UPS (230 V AC 1 phase 50 Hz)Nos176599.5176599.51.0FalseNoneNoneFalseNoneFalse176599.50
3430078121537Nonecode216Current Cables-Copper Core with cross section 4.0 sq.mm Multistrand 7 Core (4Cx10sq.mm rates considered)Mtr393.75393.7520.0FalseNoneNoneFalseNoneFalse7875.00
3430079121537Nonecode217Voltage Cables-Copper Core with cross section 2.5 sq.mm Multistrand 4 CoreMtr149.1149.120.0FalseNoneNoneFalseNoneFalse2982.00
3430080121537Nonecode218Signal Cables-armoured Copper Core with cross section 0.5 sq.mm Multi strand 10 CoreMtr150.15150.15500.0FalseNoneNoneFalseNoneFalse75075.00
3430081121537Nonecode219Control cables-Copper core with cross section1.5 sq.mm Multi strand 10 CoreMtr162.75162.75160.0FalseNoneNoneFalseNoneFalse26040.00
3430082121537Nonecode220Supply Cables-Copper Core with cross section 4.0 sq.mm Multi strand 3 Core for AC input to UPS & UPS to RTU,conforming to KPTCL specifications.Mtr166.95166.9515.0FalseNoneNoneFalseNoneFalse2504.250
3430083121537Nonecode221Supply Cables-Copper Core with cross section 32.0 sq.mm Multi strand for Battery conforming to KPTCL specifications.Mtr399.0399.030.0FalseNoneNoneFalseNoneFalse11970.00
3430084121537Nonecode222Errection charges : Equipments for establishing SCADA communication : Remote Terminal Unit (RTU)Nos26868.4526868.451.0FalseNoneNoneFalseNoneFalse26868.450
3430085121537Nonecode223Data Concentrator Unit DCU)Nos12705.012705.01.0FalseNoneNoneFalseNoneFalse12705.00
3430086121537Nonecode2242 kVA online UPS (230 V AC 1 phase 50 Hz)Nos6808.26808.21.0FalseNoneNoneFalseNoneFalse6808.20
3430087121537Nonecode225Integration of RTU,DCU and UPS with field equipmentsNos28361.5528361.551.0FalseNoneNoneFalseNoneFalse28361.550
3430088121537Nonecode226Cables - Supplying and Laying: Current Cables-Copper Core with cross section 4.0 sq.mm Multistrand 7 Core (4Cx10sq.mm rates considered)Mtr15.7515.7520.0FalseNoneNoneFalseNoneFalse315.00
3430089121537Nonecode227Voltage Cables-Copper Core with cross section 2.5 sq.mm Multistrand 4 CoreMtr15.7515.7520.0FalseNoneNoneFalseNoneFalse315.00
3430090121537Nonecode228Signal Cables-armoured Copper Core with cross section 0.5 sq.mm Multi strand 10 CoreMtr15.7515.75500.0FalseNoneNoneFalseNoneFalse7875.00
3430091121537Nonecode229Control cables Copper core with cross section 1.5 sq.mm Multi strand 10 CoreMtr15.7515.75160.0FalseNoneNoneFalseNoneFalse2520.00
3430092121537Nonecode230Supply Cables-Copper Core with cross section 4.0 sq.mm Multi strand 3 Core for AC input to UPS & UPS to RTU,conforming to KPTCL specifications.Mtr15.7515.7515.0FalseNoneNoneFalseNoneFalse236.250
3430093121537Nonecode231Supply Cables-Copper Core with cross section 32.0 sq.mm Multi strand for Battery conforming to KPTCL specifications. Satelite Communication required will be arranged by SLDC.Mtr15.7515.7530.0FalseNoneNoneFalseNoneFalse472.50
3430094121537Nonecode232Earth Mat Formation (Errection charges): Supplying and laying MS.Flat 50 x 6 mm flat welding and applying ACB paint to welded portion and covering with Sodium Bentonite Clay (SBC supplied by Corporation) as per drawing/standard (all other materials to be supplied by contractor)Rmtr424.2424.22460.0FalseNoneNoneFalseNoneFalse1043532.00
3430095121537Nonecode233Grounding of equipments with 50 x 6 mm GI flat and connecting equipments to the earth mat/ground pit including all connected works with all materials supplied by the contractor.Rmtr351.75351.751118.0FalseNoneNoneFalseNoneFalse393256.50
3430096121537Nonecode234Providing 25mm dia, 1.05mtr. Long Earthmat Spike MS Rod including bending top 50mm etcNo475.65475.6570.0FalseNoneNoneFalseNoneFalse33295.50
3430097121537Nonecode235Material cost: Providing C.I. Pipe of l00mm ID 13mm thick 2.75mtr. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation (all materials supplied by contractor)No13431.613431.670.0FalseNoneNoneFalseNoneFalse940212.00
3430098121537Nonecode236Errection charges: Providing C.I. Pipe of l00mm ID 13mm thick 2.75mtr. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation (all materials supplied by contractor)Set3665.553665.5544.0FalseNoneNoneFalseNoneFalse161284.20
3430099121537Nonecode237Errection charges: Supplying and fixing 4S0mm dia x 450mm height 15"to 2" Hume pipe collars for earth pits.No1573.951573.9544.0FalseNoneNoneFalseNoneFalse69253.80
3430100121537Nonecode238Errection charges: Station and yard Lighting (Outdoor) to be designed, assessed and Quoted by the bidder): Design of Station yard illumination in confirmity with the illumination levels mentioned in the technical specification, supply & erection of station yard illumination materials /equipment including lamp post(fabricated galvanised structures), Illumination fittings, control gears, UG/OH cables, conduit pipes, control boxes etc,. including necessary civil works, completeLS315000.0315000.01.0FalseNoneNoneFalseNoneFalse315000.00
3430101121537Nonecode239Material cost: Station Mandatpry spares: (Rates of 110KV Sagnoor DWA is considered): Circuit breaker (CB) closing coil with resistor (For one complete circuit breaker) a) for 123KV CBSet10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
3430102121537Nonecode240Tripping coil with resistor (For one complete circuit breaker) a) for 12KV CBSet12600.012600.01.0FalseNoneNoneFalseNoneFalse12600.00
3430103121537Nonecode241Teminal pad (For one complete circuit breaker) a) for 123KV CBSet12600.012600.01.0FalseNoneNoneFalseNoneFalse12600.00
3430104121537Nonecode242Terminal connector (For one complete circuit breaker) a) for 123KV CBSet10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
3430105121537Nonecode243SF6 Gas (40% of total gas Qty of each sub-station) for sub-station at SagnoorLS52500.052500.01.0FalseNoneNoneFalseNoneFalse52500.00
3430106121537Nonecode244Isolator: Copper contract fingers male & female (For one complete isolator )a) for 123KV ClassSet52500.052500.01.0FalseNoneNoneFalseNoneFalse52500.00
3430107121537Nonecode245Teminal connector (For one complete isolator) ) for 123KV classSet10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
3430108121537Nonecode246Terminal pad (For one complete isolator) ) for 123KV classSet10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
17198417270000NoneNoneElectricalEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi. (PART B SUB STATION CIVIL WORKS)30260895.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430109121538Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum99.7599.75980.0FalseNoneNoneFalseNoneFalse97755.00
3430110121538Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.13679.8993FalseNoneNoneFalseNoneFalse394117.215030
3430111121538Nonecode03Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling, water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.71995.15FalseNoneNoneFalseNoneFalse992986.1550
3430112121538Nonecode04Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.2250.4FalseNoneNoneFalseNoneFalse1489178.880
3430113121538Nonecode05Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation add at 3%Cum6799.396799.39170.82FalseNoneNoneFalseNoneFalse1161471.79980
3430114121538Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation of drains add at 35%Cum8911.828911.82119.45FalseNoneNoneFalseNoneFalse1064516.8990
3430115121538Nonecode07Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation of retaining wall add at 10% for formworkCum7261.497261.491120.79FalseNoneNoneFalseNoneFalse8138605.37710
3430116121538Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For column upto PB add at 70%Cum11222.311222.340.0FalseNoneNoneFalseNoneFalse448892.00
3430117121538Nonecode09Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For PB add at 50%Cum9958.739958.735.0FalseNoneNoneFalseNoneFalse49793.650
3430118121538Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams & lintels add at 60% Ground floorCum11138.411138.436.0FalseNoneNoneFalseNoneFalse400982.40
3430119121538Nonecode11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For columns of super structure add at 70% Ground floorCum11834.5511834.5518.4FalseNoneNoneFalseNoneFalse217755.720
3430120121538Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof slab add at 50% - Ground floorCum10442.2510442.2527.0FalseNoneNoneFalseNoneFalse281940.750
3430121121538Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chejjas & Canopy of CRB add at 45% for formworkCum10094.1810094.185.0FalseNoneNoneFalseNoneFalse50470.90
3430122121538Nonecode15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregate for DPC sill coping & screed concrete add at 5%Cum6854.246854.2437.84FalseNoneNoneFalseNoneFalse259364.44160
3430123121538Nonecode16Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for plinth protection & floor concrete of CRBCum6527.856527.857.25FalseNoneNoneFalseNoneFalse47326.91250
3430124121538Nonecode17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8293.018293.0144.5FalseNoneNoneFalseNoneFalse369038.9450
3430125121538Nonecode18Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4534.49FalseNoneNoneFalseNoneFalse231374.44050
3430126121538Nonecode19Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.4597.9445FalseNoneNoneFalseNoneFalse819545.7065250
3430127121538Nonecode20Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1375.51375.5810.905FalseNoneNoneFalseNoneFalse1115399.82750
3430128121538Nonecode21Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of inchargeSqm1475.251475.25154.56FalseNoneNoneFalseNoneFalse228014.640
3430129121538Nonecode22Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.0195.37FalseNoneNoneFalseNoneFalse32822.160
3430130121538Nonecode23Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm327.6327.6118.0FalseNoneNoneFalseNoneFalse38656.80
3430131121538Nonecode24Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm371.7371.72952.55FalseNoneNoneFalseNoneFalse1097462.8350
3430132121538Nonecode25Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent..Sqm2994.62994.6105.0FalseNoneNoneFalseNoneFalse314433.00
3430133121538Nonecode26Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc tion of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1308.31308.320.0FalseNoneNoneFalseNoneFalse26166.00
3430134121538Nonecode27Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1323.01323.036.0FalseNoneNoneFalseNoneFalse47628.00
3430135121538Nonecode28Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeSqm933.45933.4510.0FalseNoneNoneFalseNoneFalse9334.50
3430136121538Nonecode29Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.630.0FalseNoneNoneFalseNoneFalse43848.00
3430137121538Nonecode30Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm105.0105.0500.0FalseNoneNoneFalseNoneFalse52500.00
3430138121538Nonecode31Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm163.8163.8480.0FalseNoneNoneFalseNoneFalse78624.00
3430139121538Nonecode32Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.74126.05FalseNoneNoneFalseNoneFalse753829.3350
3430140121538Nonecode33Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification BuildingsKg93.9393.937500.0FalseNoneNoneFalseNoneFalse704475.00
3430141121538Nonecode34Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structuresKg82.9682.9660748.99FalseNoneNoneFalseNoneFalse5039736.21040
3430142121538Nonecode35Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm8689.88689.86.0FalseNoneNoneFalseNoneFalse52138.80
3430143121538Nonecode36Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg599.55599.55583.2FalseNoneNoneFalseNoneFalse349657.560
3430144121538Nonecode37Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specificationsSqm1229.551229.5561.79FalseNoneNoneFalseNoneFalse75973.89450
3430145121538Nonecode38Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width including cost of materials, labour, usage charges of machinery complete as per specifications.m310.8310.8250.0FalseNoneNoneFalseNoneFalse77700.00
3430146121538Nonecode39Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specificationsNo458.85458.855.0FalseNoneNoneFalseNoneFalse2294.250
3430147121538Nonecode40Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNo136.5136.55.0FalseNoneNoneFalseNoneFalse682.50
3430148121538Nonecode41Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)No288.75288.7521.0FalseNoneNoneFalseNoneFalse6063.750
3430149121538Nonecode42Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg593.25593.25200.0FalseNoneNoneFalseNoneFalse118650.00
3430150121538Nonecode43Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelamSqm2484.32484.33.15FalseNoneNoneFalseNoneFalse7825.5450
3430151121538Nonecode44Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3m431.55431.5560.0FalseNoneNoneFalseNoneFalse25893.00
3430152121538Nonecode45Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing 150 mm dia. pipes (V.5,SOR code T030B P.No. 184)m489.3489.330.0FalseNoneNoneFalseNoneFalse14679.00
3430153121538Nonecode46Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.21.0FalseNoneNoneFalseNoneFalse5128.20
3430154121538Nonecode47Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and bracket , cutting and making good the walls and floors wherever required : 14.3.1 W.C. pan with ISI marked white solid plastic seat and lidEach6275.856275.851.0FalseNoneNoneFalseNoneFalse6275.850
3430155121538Nonecode48Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.12.0FalseNoneNoneFalseNoneFalse6472.20
3430156121538Nonecode49Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions)Each1119.31119.32.0FalseNoneNoneFalseNoneFalse2238.60
3430157121538Nonecode50Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangment and making necessary holes for inlet, outlet and overflow pipes but without fitting and the base support for tank.l9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3430158121538Nonecode51Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 89 mm long, weighing not less than 88 gNo151.2151.21.0FalseNoneNoneFalseNoneFalse151.20
3430159121538Nonecode52Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gNo137.55137.551.0FalseNoneNoneFalseNoneFalse137.550
3430160121538Nonecode53Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg118.65118.658501.91FalseNoneNoneFalseNoneFalse1008751.62150
3430161121538Nonecode54Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each7786.87786.812.0FalseNoneNoneFalseNoneFalse93441.60
3430162121538Nonecode55Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN6.0 - 63mm diam229.95229.95155.0FalseNoneNoneFalseNoneFalse35642.250
3430163121538Nonecode5632 mm nominal dia Pipesm390.6390.6100.0FalseNoneNoneFalseNoneFalse39060.00
3430164121538Nonecode5725 mm nominal dia Pipesm310.8310.8120.0FalseNoneNoneFalseNoneFalse37296.00
3430165121538Nonecode5820 mm nominal dia Pipesm227.85227.8580.0FalseNoneNoneFalseNoneFalse18228.00
3430166121538Nonecode59Providing and fixing Rainy dual capacity self-cleaning roof top rain water harvesting filter or equivalent filter of FL-500 specification suitable for a catchment area of about 500Sqm.No11025.011025.01.0FalseNoneNoneFalseNoneFalse11025.00
3430167121538Nonecode60Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments 1.50 HP/1.1KW 12 STGNo16188.916188.91.0FalseNoneNoneFalseNoneFalse16188.90
3430168121538Nonecode61Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia 4 mmSqm843.15843.15418.6FalseNoneNoneFalseNoneFalse352942.590
3430169121538Nonecode62Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately).Payment to be made per metre cost of total length of barbed wire used. With G.I.barbed wire.m18.918.91899.0FalseNoneNoneFalseNoneFalse35891.10
3430170121538Nonecode63GI flat 50mm x 6mm & Bolts for SF PolesKgs351.75351.751116.13FalseNoneNoneFalseNoneFalse392598.72750
3430171121538Nonecode64Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 0 to 50 m - Water supply Upto 50.00 mtrs.m388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3430172121538Nonecode65Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc.complete. The cost excludes the cost of casing pipes, collars & caps etc.) for:Borewell depth of 50 to 100 mm487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3430173121538Nonecode66Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 100 to 150 mm517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
3430174121538Nonecode67Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 150 to 200 mm600.6600.610.0FalseNoneNoneFalseNoneFalse6006.00
3430175121538Nonecode68Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutym2029.652029.6520.0FalseNoneNoneFalseNoneFalse40593.00
3430176121538Nonecode69Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3430177121538Nonecode70Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3430178121538Nonecode71PUMPSET : Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For HP For 6.50 HP 6.50 HP - 90 LPM @ 132 m = 12 STG Outlet Dia - 2.00”Each38554.9538554.951.0FalseNoneNoneFalseNoneFalse38554.950
3430179121538Nonecode72SUBMERSIBLE CABLE: Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2m141.75141.75200.0FalseNoneNoneFalseNoneFalse28350.00
3430180121538Nonecode73PRESSURE GAUGE : Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments - Size 100 mmEach686.7686.71.0FalseNoneNoneFalseNoneFalse686.70
3430181121538Nonecode74GATE VALVE : Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
3430182121538Nonecode75NON - RETURN VALVE : Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
3430183121538Nonecode76ix) Control Panel BOARD-A: Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2)S-D- Star Delta Starter for outdoor Upto 6 HP pumpsEach16695.016695.01.0FalseNoneNoneFalseNoneFalse16695.00
3430184121538Nonecode77POWER CAPACITOR : Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3430185121538Nonecode78MCB : Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.Per 3 Poles1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3430186121538Nonecode79Erection elctrification & Commissioning works of pumpsets : Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of workJob6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3430187121538Nonecode80Ercerion of panel board & meter board Unit : Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipmentsincluding providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3430188121538Nonecode81Main connections: Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.m141.75141.751.0FalseNoneNoneFalseNoneFalse141.750
3430189121538Nonecode82Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3430190121538Nonecode83Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer in-charge of works as per the standard procedure.Sqm186.17186.173260.0FalseNoneNoneFalseNoneFalse606914.20
3430191121538Nonecode84Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. PVC 160MM 10KG/M2 for Cable duct E & F Typem1017.451017.4550.0FalseNoneNoneFalseNoneFalse50872.50
3430192121538Nonecode85Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 900 mm dia. for culvertm5096.75096.712.5FalseNoneNoneFalseNoneFalse63708.750
3430193121538Nonecode86Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch boxEach Point282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3430194121538Nonecode87Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch boxEach Point397.95397.9515.0FalseNoneNoneFalseNoneFalse5969.250
3430195121538Nonecode88Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( 4/9) - II. Point wiring using class B Materialsc) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch boxEach Point582.75582.7515.0FalseNoneNoneFalseNoneFalse8741.250
3430196121538Nonecode89Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia.2.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickPer Mtr81.981.9150.0FalseNoneNoneFalseNoneFalse12285.00
3430197121538Nonecode90Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854. 6A 2 WayEach134.4134.415.0FalseNoneNoneFalseNoneFalse2016.00
3430198121538Nonecode91Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854. 6A 3/5 WayEach154.35154.3515.0FalseNoneNoneFalseNoneFalse2315.250
3430199121538Nonecode92Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP SwitchEach342.3342.310.0FalseNoneNoneFalseNoneFalse3423.00
3430200121538Nonecode93Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach247.8247.81.0FalseNoneNoneFalseNoneFalse247.80
3430201121538Nonecode94Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/ Telephone SocketEach163.8163.81.0FalseNoneNoneFalseNoneFalse163.80
3430202121538Nonecode95Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 1.5 sqmmm27.327.3600.0FalseNoneNoneFalseNoneFalse16380.00
3430203121538Nonecode96Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 2.5 sqmmm44.144.1450.0FalseNoneNoneFalseNoneFalse19845.00
3430204121538Nonecode97Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 4 sqmmm66.1566.15270.0FalseNoneNoneFalseNoneFalse17860.50
3430205121538Nonecode98Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayEach144.9144.910.0FalseNoneNoneFalseNoneFalse1449.00
3430206121538Nonecode99Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
3430207121538Nonecode100Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach231.0231.02.0FalseNoneNoneFalseNoneFalse462.00
3430208121538Nonecode101Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach334.95334.956.0FalseNoneNoneFalseNoneFalse2009.70
3430209121538Nonecode102Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 ModuleEach143.85143.8510.0FalseNoneNoneFalseNoneFalse1438.50
3430210121538Nonecode103Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 ModuleEach183.75183.754.0FalseNoneNoneFalseNoneFalse735.00
3430211121538Nonecode104Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 ModuleEach245.7245.72.0FalseNoneNoneFalseNoneFalse491.40
3430212121538Nonecode105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 ModuleEach361.2361.26.0FalseNoneNoneFalseNoneFalse2167.20
3430213121538Nonecode106Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach189.0189.010.0FalseNoneNoneFalseNoneFalse1890.00
3430214121538Nonecode107Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with RemoteEach258.3258.31.0FalseNoneNoneFalseNoneFalse258.30
3430215121538Nonecode108Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 12" Sweep (300mm)Each3117.453117.454.0FalseNoneNoneFalseNoneFalse12469.80
3430216121538Nonecode109Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200mm) Regular modelEach3133.23133.24.0FalseNoneNoneFalseNoneFalse12532.80
3430217121538Nonecode110Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.554.0FalseNoneNoneFalseNoneFalse718.20
3430218121538Nonecode111Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frameEach742.35742.354.0FalseNoneNoneFalseNoneFalse2969.40
3430219121538Nonecode112Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach374.85374.854.0FalseNoneNoneFalseNoneFalse1499.40
3430220121538Nonecode113Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., Made out of 14 SWG MS enclosur - Double Door 12Way SP &NEach2445.452445.451.0FalseNoneNoneFalseNoneFalse2445.450
3430221121538Nonecode114Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., Made out of 14 SWG MS enclosur - Double Door 6 Way SP &NEach1880.551880.551.0FalseNoneNoneFalseNoneFalse1880.550
3430222121538Nonecode115Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SPEach435.75435.751.0FalseNoneNoneFalseNoneFalse435.750
3430223121538Nonecode116Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63A SPEach851.55851.551.0FalseNoneNoneFalseNoneFalse851.550
3430224121538Nonecode117Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 Amps 4 poleEach5404.355404.351.0FalseNoneNoneFalseNoneFalse5404.350
3430225121538Nonecode118Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit. The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc., the pipe shall have 16 through holes of 12 mm dia.No3685.53685.51.0FalseNoneNoneFalseNoneFalse3685.50
3430226121538Nonecode119Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each4468.84468.81.0FalseNoneNoneFalseNoneFalse4468.80
3430227121538Nonecode120GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm copper plateEach7792.057792.051.0FalseNoneNoneFalseNoneFalse7792.050
3430228121538Nonecode121Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. Copper wire. c) 8 SWGm110.25110.2520.0FalseNoneNoneFalseNoneFalse2205.00
3430229121538Nonecode123Supplying, fixing and wiring 0 to 600Volts 96x96mm AC Voltmeter on existing panel/wood board.Each474.6474.61.0FalseNoneNoneFalseNoneFalse474.60
3430230121538Nonecode124Supplying, fixing and wiring 0 to 1500amps CT operated AC analog type Ammeter With out CT)Each504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3430231121538Nonecode125Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wiredEach4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3430232121538Nonecode126Supplying, fixing and wiring rotary selector switch suitable for Ammeter.Each210.0210.01.0FalseNoneNoneFalseNoneFalse210.00
3430233121538Nonecode127Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer class 0.5 accurecy with Tape WoundEach590.1590.11.0FalseNoneNoneFalseNoneFalse590.10
3430234121538Nonecode128Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.CEach540.75540.7510.0FalseNoneNoneFalseNoneFalse5407.50
3430235121538Nonecode129Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
3430236121538Nonecode130Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Micro processor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism THREE POLE 200Amps 36kAEach17892.017892.01.0FalseNoneNoneFalseNoneFalse17892.00
3430237121538Nonecode131Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947 - 125AmpsEach6087.96087.91.0FalseNoneNoneFalseNoneFalse6087.90
3430238121538Nonecode132Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire, manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. 40WattsEach4225.24225.215.0FalseNoneNoneFalseNoneFalse63378.00
3430239121538Nonecode133Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete - 16SWGSq CM0.450.452000.0FalseNoneNoneFalseNoneFalse900.00
3430240121538Nonecode134Supplying of feet -PVC Batten with integrated LED tube LED light fitting 1 x 4ft - 36/40 W W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionEach1332.451332.4520.0FalseNoneNoneFalseNoneFalse26649.00
3430241121538Nonecode135Supplying of feet -PVC Batten with integrated LED tube LED light fitting 1 x 2ft - 9/10 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionEach578.55578.555.0FalseNoneNoneFalseNoneFalse2892.750
3430242121538Nonecode136Supply of round/square recess/surface mounted rolling type LED Down light withLED square or round down light 5-6W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionEach599.55599.554.0FalseNoneNoneFalseNoneFalse2398.20
3430243121538Nonecode137Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each128.1128.110.0FalseNoneNoneFalseNoneFalse1281.00
3430244121538Nonecode54Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each6507.96507.915.0FalseNoneNoneFalseNoneFalse97618.50
17198417270000NoneNoneElectricalEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi. (PART B1 Check survey to be conducted during construction stage)17711658.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430245121539Nonecode001Check survey to be conducted during construction stage: Labour charge for Conducting detailed check survey along the approved route duly following the route alignment, GPS Co-ordinates, submission of detailed line schedule, tower schedule, land schedule and comparing the same with respect to detailed survey report, bringing out the differences if any. Submission of contour maps for undulated / hilly tower. The work also includes marking corridor width in the field and computing the quantum of beaching and revetment, preparation of detailed land schedule at ong the corridor on the digitized Reven ue vi1lage maps indicating the Sy. Nos. falling within the corridor for the purpose of estimation of the land compensation, submission of detailed consolidated hatd copy of reports of check survey in 6 sets along with soft copy for approval in all types of terrain per Km.Per Km3049.23049.21.076FalseNoneNoneFalseNoneFalse3280.93920
3430246121539Nonecode02Proposed 220/110KV MC Narrow Based Towers (M/s L&T Design): Material cost: Proposed 220/110KV MC Narrow Based Towers (M/s L&T Design) MD' Type Tower with Box Cross Arm with Stubs MSNos142296.0142296.016.53FalseNoneNoneFalseNoneFalse2352152.880
3430247121539Nonecode03Material cost: Proposed 220/110KV MC Narrow Based Towers (M/s L&T Design) MD' Type Tower with Box Cross Arm with Stubs HTNos156271.5156271.516.296FalseNoneNoneFalseNoneFalse2546600.3640
3430248121539Nonecode04Labour charges: Proposed 220/110KV MC Narrow Based Towers (M/s L&T Design) MD' Type Tower with Box Cross Arm with Stubs MSNos6463.86463.816.53FalseNoneNoneFalseNoneFalse106846.6140
3430249121539Nonecode05Labour charges: Proposed 220/110KV MC Narrow Based Towers (M/s L&T Design) MD' Type Tower with Box Cross Arm with Stubs HTNos6463.86463.816.296FalseNoneNoneFalseNoneFalse105334.08480
3430250121539Nonecode06Proposed 110KV DC Narrow Based Towers (KPTCL Design): Material cost: Proposed 110KV DC Narrow Based Towers of Normal, extension tower, 9th cross arm with stubsNos142296.0142296.054.09FalseNoneNoneFalseNoneFalse7696790.640
3430251121539Nonecode07Labour charge: Proposed 110KV DC Narrow Based Towers of Normal, extension tower, 9th cross arm with stubsNos6463.86463.854.09FalseNoneNoneFalseNoneFalse349626.9420
3430252121539Nonecode08Material cost: Supply of Galvanised Bolts , Nuts & washerMT149919.0149919.03.016FalseNoneNoneFalseNoneFalse452155.7040
3430253121539Nonecode09Labour charge: Supply of Galvanised Bolts , Nuts & washerMT6009.156009.153.016FalseNoneNoneFalseNoneFalse18123.59640
3430254121539Nonecode10Labour charge: Stub setting templates : Setting of stub templates and aligning,dismantling and transportation of templates from one location to the other location for 110 KVLS931.35931.358.0FalseNoneNoneFalseNoneFalse7450.80
3430255121539Nonecode11Setting of stub templates and aligning,dismantling and transportation of templates from one location to the other location for 220KVLS1329.31329.32.0FalseNoneNoneFalseNoneFalse2658.60
3430256121539Nonecode12Tower Acessories: Labour charge: Supplying and fixing G.I. Angle iron 450 x 450(1 m length) with cleats, bolt & nuts as per specification and fixing above 0.5 m length each at inner and outer surface of the tower to facilitate running of barbed wire.Set4327.054327.0510.0FalseNoneNoneFalseNoneFalse43270.50
3430257121539Nonecode13Labour charge: Supplying and fixing Barbed wireRmtr79.879.81251.52FalseNoneNoneFalseNoneFalse99871.2960
3430258121539Nonecode14Material cost:Number PlatesNo333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3430259121539Nonecode15Labaour charge: Number PlatesNo84.084.010.0FalseNoneNoneFalseNoneFalse840.00
3430260121539Nonecode16Material cost: Danger BoardsNo333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3430261121539Nonecode17Labaour charge: Danger BoardsNo84.084.010.0FalseNoneNoneFalseNoneFalse840.00
3430262121539Nonecode18Material cost: Phase plate (Set of 3 No.)No277.2277.210.0FalseNoneNoneFalseNoneFalse2772.00
3430263121539Nonecode19Labaour charge:Phase plate (Set of 3 No.)No249.9249.910.0FalseNoneNoneFalseNoneFalse2499.00
3430264121539Nonecode20Material cost: Circuit plateNo333.9333.920.0FalseNoneNoneFalseNoneFalse6678.00
3430265121539Nonecode21Labaour charge: Circuit plateNo84.084.020.0FalseNoneNoneFalseNoneFalse1680.00
3430266121539Nonecode22Material cost: Earth bond 450 mm longNo564.9564.910.0FalseNoneNoneFalseNoneFalse5649.00
3430267121539Nonecode23Material cost: Grounding of tower with GI Pipe including the cost of GI pipe, GI wire etc,.Set54852.054852.010.0FalseNoneNoneFalseNoneFalse548520.00
3430268121539Nonecode24Labaour charge: Grounding of tower with GI Pipe including the cost of GI pipe, GI wire etc,.Set2216.552216.5510.0FalseNoneNoneFalseNoneFalse22165.50
3430269121539Nonecode25Conductor and Ground Wire:: Material cost:Lynx ACSR (In Plain terrain)Km201600.0201600.06.553FalseNoneNoneFalseNoneFalse1321084.80
3430270121539Nonecode26Labour charge: Lynx ACSR (In Plain terrain)Km8400.08400.06.553FalseNoneNoneFalseNoneFalse55045.20
3430271121539Nonecode27Material cost: 7/3.15 mm Ground wire (In plain terrain) including Anchor tower DroppingsKm92400.092400.01.092FalseNoneNoneFalseNoneFalse100900.80
3430272121539Nonecode28Labour charge: 7/3.15 mm Ground wire (In plain terrain) including Anchor tower DroppingsKm11550.011550.01.092FalseNoneNoneFalseNoneFalse12612.60
3430273121539Nonecode29Material cost of Insulator strings and clamps for Lynx ACSR conductor with Hardware and Arcing horns.: Single Tension string of 90 KN Disc Insulators 8 units each along with hardware for Lynx ACSR and arcing hornStack6704.256704.25126.0FalseNoneNoneFalseNoneFalse844735.50
3430274121539Nonecode30Double Tension string of 90 KN Disc Insulators 8 units each along with hard ware for Lynx ACSR and arcing hornStack14866.9514866.9524.0FalseNoneNoneFalseNoneFalse356806.80
3430275121539Nonecode31Single Suspension string of 90 KN Disc Insulators 7 units each.along with hardware for Lynx ACSR and arcing hornStack6451.26451.26.0FalseNoneNoneFalseNoneFalse38707.20
3430276121539Nonecode32Material cost of Accessories for Lynx ACSR Conductor: M S C Joints suitable for Lynx ACSRNo701.4701.44.0FalseNoneNoneFalseNoneFalse2805.60
3430277121539Nonecode33Pre formed armour rods suitable for Lynx ACSRNo1326.151326.156.0FalseNoneNoneFalseNoneFalse7956.90
3430278121539Nonecode34Repair sleeves suitable for Lynx ACSRNos621.6621.64.0FalseNoneNoneFalseNoneFalse2486.40
3430279121539Nonecode35P G Clamps suitable for LYNX ACSRNos814.8814.8150.0FalseNoneNoneFalseNoneFalse122220.00
3430280121539Nonecode36Vibration dampers for LynxNos1064.71064.7120.0FalseNoneNoneFalseNoneFalse127764.00
3430281121539Nonecode37Hardware & Accessories for Ground Wire.: Material cost of M S C Joints suitable for Ground conductorNo479.85479.852.0FalseNoneNoneFalseNoneFalse959.70
3430282121539Nonecode38Material cost of Repair sleeves suitable for Ground conductorNo324.45324.452.0FalseNoneNoneFalseNoneFalse648.90
3430283121539Nonecode39Material cost of P G Clamps suitable for GROUND ACSRNos423.15423.1510.0FalseNoneNoneFalseNoneFalse4231.50
3430284121539Nonecode40Material cost of Single Tension clamps (bolted type) suitable for Ground conductorNos1295.71295.710.0FalseNoneNoneFalseNoneFalse12957.00
3430285121539Nonecode41Labour charge of Tack welding of Bolts and Nuts (No of tower x 250)Nos23.123.13000.0FalseNoneNoneFalseNoneFalse69300.00
3430286121539Nonecode42Labour charge of Releasing & Restringing of Existing Lynx ACSR Conductor and Releasing of existing tower, conductor and ground wire: Releasing of existing. MA-type, 1Nos of tower (8.2904MT per tower, i.e. 70% of MC A-type, M/s Ramachandra Rao design tower weight )-including the released Materials has to be returned to the nearest KPTCL Store.MT6009.156009.155.8FalseNoneNoneFalseNoneFalse34853.070
3430287121539Nonecode43Releasing & Restringing of Existing Lynx ACSR Conductor from Existing AP to proposed LILO towers on both sides for a lentgh of 1.178Kms*9*1.015=10.761Kms [3 Cicuits ]- Release -8000 and Stringing-8000- total -16000/-Km16800.016800.010.761FalseNoneNoneFalseNoneFalse180784.80
3430288121539Nonecode44Releasing & Restringing of Existing Ground Wire from Existing AP to proposed LILO towers on both sides for a lentgh of 1.178KmsKms*1*1.015=1.196Kms under LC ConditionKm23100.023100.01.196FalseNoneNoneFalseNoneFalse27627.60
3430289121539Nonecode45Labour charge of Clearing for bushes tree branches etc.,as per specificationKm4354.354354.351.076FalseNoneNoneFalseNoneFalse4685.28060
17198417280000NoneNoneElectricalEstablishing 2x10MVA, 110/11 KV Sub-station on the layout at Kotnoor-D Atal Bhihari Vajpayee Kalaburagi with construction of 110 KV LILO line from existing 110 KV Kalaburagi South to Kalaburagi West line for a distance of 1.076Kms for the work of Arranging power supply to an extent of 7488KVA (6365KW) for electrification of residential / Commercial layout at Sy No. 49, 66, 67, 68, 74, 76, 77, 96, 97 at Kotnoor-D Kalaburagi. (PART C ASSOCIATED CIVIL WORKS AND STRUCTURES)7748725.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3430290121540Nonecode01Excavation for foundation (only labour) : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m-Cum107.1107.1776.46FalseNoneNoneFalseNoneFalse83158.8660
3430291121540Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth.-Dry fissured/Ordinary rock upto 1.5mCum381.15381.15105.882FalseNoneNoneFalseNoneFalse40356.92430
3430292121540Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth exceeding 1.5 m but not exceeding 3 m depth -Dry fissured/Ordinary rock upto 3.0mCum446.25446.25247.058FalseNoneNoneFalseNoneFalse110249.63250
3430293121540Nonecode04Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock (requiring blasting) Depth upto 1.50m (KPWD SR 23-24 V1, Page.No.9 Item No.1.16.1)-Hard Rock/Hard laterite upto 1.5mCum581.7581.721.177FalseNoneNoneFalseNoneFalse12318.66090
3430294121540Nonecode05Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m (KPWD SR 23-24 V1, Page.No.9 Item No.1.16.2)-Hard Rock/Hard laterite upto 3.0mCum654.15654.1549.413FalseNoneNoneFalseNoneFalse32323.513950
3430295121540Nonecode06Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils upto 3.0 m depth with 5% with de-watering is assessed as per site condition (KPWD SR 23-24 V1, Page.No.8 Item No.1.14.1) -PSS/FSS upto 3.0mCum895.65895.65211.76FalseNoneNoneFalseNoneFalse189662.8440
3430296121540Nonecode07Foundation Concreting : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (V.1, I.No.2.1.4, P.No.15)-Concreting and curing 1 : 3 : 6Cum6527.856527.8521.55FalseNoneNoneFalseNoneFalse140675.16750
3430297121540Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications (V1/Pg15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation - Concreting and curing M20Cum6799.396799.39613.6FalseNoneNoneFalseNoneFalse4172105.7040
3430298121540Nonecode09Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structures -Steel reinforcement (including material and labour)MT82960.582960.533.16FalseNoneNoneFalseNoneFalse2750970.180
3430299121540Nonecode10Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -Back FillingCum279.3279.3776.6FalseNoneNoneFalseNoneFalse216904.380
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17198417290001NoneNoneELIGIBILITYTenders from Joint ventures are acceptable.None
17198417290000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17198417290000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17198417290000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17198417290000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17198417520000NoneNoneELIGIBILITYAll Terms and conditions as per Tender Document and Tender NotificationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactorily completed (at least 50% of the contract value), as prime contractor, at least one similar work such as Construction of Electrical Sub-station Works of value not less than Rs 750.05 lakhs.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe bidder should have executed the works satisfactorily and commissioned more than one year for the following items involved in the work 1) Supplying, Testing and Commissioning of minimum 8 MVA and above capacity power transformers Nos. 01 2) Supply and Laying 66 KV EHV UG cable Km 01 3) Supplying and installation of 11 KV MCVCB Switch gears Nos.08 4) Construction of Control Room, compound wall Job 01Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBidder should posses conditioned road worthy vehicle or hired one. 1) Lorries/Tipper 01 Nos 2) Crane 01 Nos 3) Ladder mounted Jeep 01 Nos.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Machinery details
NoneNoneNoneNoneElectrical license contractor valid Super grade issued from Chief Electrical Inspectorate of Karnataka GovtCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical license
NoneNoneNoneNoneRegistration certificate of GSTCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration certificate of GST
NoneNoneNoneNoneRegistration certificate issued from Provident Fund Authority (EPF)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration certificate issued from Provident Fund Authority (EPF)
NoneNoneNoneNoneRegistration certification of ESI.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid ESI certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2019-20 to 2023-24) (a) Achieved in at least two financial years a minimum financial turnover (in all class of Electrical engineering construction works only) of Rs.3000.00 lakhs. (Not less than 2 times the amount put to tender)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAssets and liability amount equal to amount put to tender obtained from the C.A. (Rs 1500.11 lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- assets and liability
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of not less than 25% of the amount put tender Rs 375.03 Lakhs (Credit lines/letter of credit/ certificates from any Nationalized/Scheduled banksFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
SCAN AND UPLOAD DOCUMENTS AS PER TENDER DOCUMENT AND NOTIFICATIONTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719842713000
version0
createdDateNone
modifiedDateNone
blockNumberKUDA OFFICE, MAIN ROAD BESIDE MINI VIDHAN SAUDHA
streetNone
cityKALABURAGI
stateKarnataka
pin585102
tenderRecallDTONone