createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718351683765
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2080.00
emd166000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose16-07-2024 13:32:46
tenderQueryClose15-07-2024 17:30:00
technicalBidOpen18-07-2024 11:00:00
publishedDate01-07-2024 18:12:00
publishedByPostCMC_MCOM_ASK
publishedByUserKPE12516 - H T KRISHNAMURTHY
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonRAVIKUMAR K P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08174232201
mobileNumber9480966991
tenderSupplierListNone
tenderSchedule
createdTs1718351683768
version14
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT15122/CALL-2
titleCONSTRUCTION OF NEW SHED FOR DRY WASTE PROCESSING IN SWM SITE ARSIKERE CMC(MRF)
descriptionCONSTRUCTION OF NEW SHED FOR DRY WASTE PROCESSING IN SWM SITE ARSIKERE CMC(MRF)
categoryWORKS
categoryTextWorks
ecv8281171.65
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2322
locationNameDMA City Municipal Council Arasikere
provisionalAmount8300000.0
groupOverheadTotal1263229.57
fileNumberCMC/ASK/SWM/SBM2/MRF/1/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17183516840001NoneNoneBuildingsCONSTRUCTION OF NEW SHED FOR DRY WASTE PROCESSING IN SWM SITE ARSIKERE CMC(MRF)6615625.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3288695114293Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0669.48FalseNoneNoneFalseNoneFalse7299.56880
3288696114293Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9263.74FalseNoneNoneFalseNoneFalse371854.06080
3288697114293Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.896.57FalseNoneNoneFalseNoneFalse694608.6960
3288698114293Nonecode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11210.411210.45.86FalseNoneNoneFalseNoneFalse65692.9440
3288699114293Nonecode05KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.087.29FalseNoneNoneFalseNoneFalse70669.84320
3288700114293Nonecode06KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Cum92.1492.148272.2FalseNoneNoneFalseNoneFalse762200.5080
3288701114293Nonecode07KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6734.63FalseNoneNoneFalseNoneFalse227888.60210
3288702114293Nonecode08KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Sqm474.0474.0473.27FalseNoneNoneFalseNoneFalse224329.980
3288703114293Nonecode09KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93189.94FalseNoneNoneFalseNoneFalse240830.62420
3288704114293Nonecode10KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Kgs303.85303.85412.41FalseNoneNoneFalseNoneFalse125310.77850
3288705114293Nonecode11Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Sqm116.39116.3922905.0FalseNoneNoneFalseNoneFalse2665912.950
3288706114293Nonecode12Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.041232.44FalseNoneNoneFalseNoneFalse721026.69760
3288707114293Nonecode13KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)No103.0103.0412.41FalseNoneNoneFalseNoneFalse42478.230
3288708114293Nonecode14KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No75.1975.19205.91FalseNoneNoneFalseNoneFalse15482.37290
3288709114293Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No75.1975.19188.69FalseNoneNoneFalseNoneFalse14187.60110
3288710114293Nonecode16KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9933.75FalseNoneNoneFalseNoneFalse91529.66250
3288711114293Nonecode17KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3288712114293Nonecode18KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
17183516840000NoneNoneBuildingsCONSTRUCTION OF NEW SHED FOR DRY WASTE PROCESSING IN SWM SITE ARSIKERE CMC(MRF)402317.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3288713114294Nonecode01Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board, 16A SP Switch (Page 10PWD ELE SR,2023-24, 3.14.10)No131.0131.020.0FalseNoneNoneFalseNoneFalse2620.00
3288714114294Nonecode02Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board, 16A Three Way 5 Pin Socket, (Page 10PWD ELE SR,2023-24, 3.14.12)No115.0115.06.0FalseNoneNoneFalseNoneFalse690.00
3288715114294Nonecode03Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , 6A One Way Switch(Page 09, PWD ELE SR,2023-24, 3.6.1)No102.0102.012.0FalseNoneNoneFalseNoneFalse1224.00
3288716114294Nonecode04Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , 6/16A Universal Socket, (Page 09, PWD ELE SR,2023-24, 3.6.10)No236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3288717114294Nonecode05Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , Stepped Fan Regulator Two Module, (Page 09, PWD ELE SR,2023-24, 3.6.4)No357.0357.03.0FalseNoneNoneFalseNoneFalse1071.00
3288718114294Nonecode06Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , 6A Bakelite Ceiling Rose,(Page 10, PWD ELE SR,2023-24, 3.14.5)No78.078.02.0FalseNoneNoneFalseNoneFalse156.00
3288719114294Nonecode07Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , 6A Pendant Holder, (Page 10, PWD ELE SR,2023-24, 3.14.6)No71.071.05.0FalseNoneNoneFalseNoneFalse355.00
3288720114294Nonecode08Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 , 6A Batten Holder,( Page 10, PWD ELE SR,2023-24, 3.14.7)No74.074.05.0FalseNoneNoneFalseNoneFalse370.00
3288721114294Nonecode09Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws, (Page02, PWD ELE SR,2023-24, 1.1.2)Mtr81.081.0300.0FalseNoneNoneFalseNoneFalse24300.00
3288722114294Nonecode10Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 2010, 1.5 mm,2 (page 05, PWD ELE SR,2.3.2)Mtr26.026.0450.0FalseNoneNoneFalseNoneFalse11700.00
3288723114294Nonecode11Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 2010, 2.5 mm2 (page05, PWD ELE SR,2023-24, 2.3.3)Mtr42.042.0450.0FalseNoneNoneFalseNoneFalse18900.00
3288724114294Nonecode12Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way (page08, PWD ELE SR,2023-24, 3.4.6)Each219.0219.06.0FalseNoneNoneFalseNoneFalse1314.00
3288725114294Nonecode13Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way ( page08, PWD ELE SR , 2023-24, 3.4.6)Each261.0261.03.0FalseNoneNoneFalseNoneFalse783.00
3288726114294Nonecode14Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 200 A (Page14 , PWD ELE SR, 5.7.5)Each1429.01429.01.0FalseNoneNoneFalseNoneFalse1429.00
3288727114294Nonecode15Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 200 A (Page15, PWD ELE SR,2023-24, 5.11.4)Each13230.013230.01.0FalseNoneNoneFalseNoneFalse13230.00
3288728114294Nonecode16Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole (Page18, PWD ELE SR,2023-24, 5.20.4)Each4277.04277.010.0FalseNoneNoneFalseNoneFalse42770.00
3288729114294Nonecode17Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 2 pole,( Page18, PWD ELE SR 2023-24, 5.20.5)Each5258.05258.07.0FalseNoneNoneFalseNoneFalse36806.00
3288730114294Nonecode18Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter (Page19, PWD ELE SR 2023-24, 5.29)Each1425.01425.01.0FalseNoneNoneFalseNoneFalse1425.00
3288731114294Nonecode19Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. (Page19, PWD ELE SR 2023-24, 5.31)Each4390.04390.01.0FalseNoneNoneFalseNoneFalse4390.00
3288732114294Nonecode20supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 Way( Page 17 , PWD ELE SR 2023-24, 5.17.1)Each10329.010329.01.0FalseNoneNoneFalseNoneFalse10329.00
3288733114294Nonecode21Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionWay LED light fitting 1 x 4' - 20/22 W (Page43 , PWD ELE SR 2023-24 ,11.3.2)Each690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
3288734114294Nonecode22Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 150W (Page46 , PWD ELE SR 2023-24, 11.9.4)Each12490.012490.012.0FalseNoneNoneFalseNoneFalse149880.00
3288735114294Nonecode23Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply Page30, PWD ELE SR 2023-24Each1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3288736114294Nonecode2432 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) (Page 13 ,ESCOMs SR 2023-24, 212 32.1)Km554655.0554655.00.06FalseNoneNoneFalseNoneFalse33279.30
3288737114294Nonecode25CT Ratio - 150/5A, 0.5 Accuracy Class Page26,ESCOMs SR 2023-24cm494.0494.02.0FalseNoneNoneFalseNoneFalse988.00
3288738114294Nonecode26Supplying and Fixing Chemical earthling for grounding. Conduits, IC cut -outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm, Using 6ft.Copper bonded rod with backfill compound (Page 55 , PWD ELE SR 2023-24, 12.60.2)1 Kit6230.06230.01.0FalseNoneNoneFalseNoneFalse6230.00
3288739114294Nonecode27Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG , ( Page 20 ,PWD ELE SR 2023-24, 5.42.2)cm0.430.4369790.0FalseNoneNoneFalseNoneFalse30009.70
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17183516840000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17183516840000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17183516840000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17183516840000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abidebythe detailed instructions and conditions contained in the StandardTender documents KW-3None
17183516840000NoneNoneELIGIBILITYThe authority reserves right to accept or reject of all tenders without giving any reasonsNone
17183516840000NoneNoneELIGIBILITYBidder should be Pay Difference amount in the name Chief Ofcer, City Municipal Council, ArasikereNone
17183516840000NoneNoneELIGIBILITYBIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDNone
17183516840000NoneNoneELIGIBILITYSimilar nature of Work done Certifcate issued by the ofcer not below the rank of Executive Engineer or EquivalentNone
17183516840000NoneNoneELIGIBILITYGST will be paid at the time of bill paymentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. 664000(80% of estimated cost of tender)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract each Tenderer in its name should have in the last five years as prime contractor,at least one similar work such as one building construction or shed work of value not less than Rs.66.40 Lakhs.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx) Vide FD circular No : FD Exp-12 : 2022 Dated : 11.05.2022 Machineries were exempted for works cost upto 300.00 Lakhs .Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NA.
NoneNoneNoneNoneExecuted in any one year,the following minimum quantities of works, earth work in both excavation and bankment (combined quantities) 462.66 cum,Cement concrete (including RCC and PCC) 139.00 cum,Structural steel works and TMT Steel 24.94 MT, precoated galvanised iron profile sheets /GI Sheet works 986.00 Sqmt,BBM or concrete Solid block construction 152 Sqmt.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHED
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totaling Rs.2.00 lakhs in any one year.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executive engineer certified copies
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Declaration
NoneNoneNoneNoneTo qualify for award of this contract,each Tenderer in its name should have in the last five years i.e 2019-20, 2020-21, 2021-22 ,2022-23 to 2023-24 achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs 166.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than R25.00 Lakhs .Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of works for which tenders already submittedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- declaratioin
NoneNoneNoneNoneBanker Details for referenceFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
work done certifcateTrueTechnical Bid
GST and Service Tax Registration CertificateTrueTechnical Bid
PWD Class 1 Registration CertifcateTrueTechnical Bid
liquid assets and or availability of credit facilities of no less than Rs 25.00 LakhsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone