createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719839860926
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee640.00
emd60000.00
bidValueTypeLUMPSUM
bidValueTypeTextLumpsum
tenderReceiptClose18-07-2024 17:00:00
tenderQueryClose18-07-2024 16:00:00
technicalBidOpen19-07-2024 17:01:00
publishedDate02-07-2024 15:35:54
publishedByPostTP_CO_KTTR
publishedByUserKPE11201 - NASARULLA A
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSalomi Niharika S
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9741818603
tenderSupplierListNone
tenderSchedule
createdTs1719839860955
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT19901
titleConstruction of proposed 4TPD MRF Centre(Material recovery facility) of PEB Structure(Primary Shed) at SWM Site town panchayath kotturu limit
descriptionConstruction of proposed 4TPD MRF Centre(Material recovery facility) of PEB Structure(Primary Shed) at SWM Site town panchayath kotturu limit
categoryWORKS
categoryTextWorks
ecv2523045.70
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2481
locationNameDMA Town Panchayat Kotturu
provisionalAmount3000000.0
groupOverheadTotalNone
fileNumbertpktr/mrf/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17198398610000NoneNoneOther WorksConstruction of proposed 4TPD MRF Centre(Material recovery facility) of PEB Structure(Primary Shed) at SWM Site town panchayath kotturu limit2523045.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3429580121522Noneitem_code1KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR 2023-24)Cum105.06105.0629.41FalseNoneNoneFalseNoneFalse3089.81460
3429581121522Noneitem_code2KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR 2023-24)Cum5833.925833.9228.97FalseNoneNoneFalseNoneFalse169008.66240
3429582121522Noneitem_code3KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For footingCum7192.87192.87.12FalseNoneNoneFalseNoneFalse51212.7360
3429583121522Noneitem_code4KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For column baseCum11016.011016.01.63FalseNoneNoneFalseNoneFalse17956.080
3429584121522Noneitem_code5KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For hall grade slabCum7192.87192.828.62FalseNoneNoneFalseNoneFalse205857.9360
3429585121522Noneitem_code6KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR 2023-24 & Appendix I page No.115) for plinth beamCum9694.089694.084.82FalseNoneNoneFalseNoneFalse46725.46560
3429586121522Noneitem_code7KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR 2023-24)Kgs92.1492.142773.1FalseNoneNoneFalseNoneFalse255513.4340
3429587121522Noneitem_code8KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR 2023-24)Cum6580.676580.6716.67FalseNoneNoneFalseNoneFalse109699.76890
3429588121522Noneitem_code9KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR 2023-24)Cum474.0474.0128.79FalseNoneNoneFalseNoneFalse61046.460
3429589121522Noneitem_code10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR 2023-24)Sqm1267.961267.9691.08FalseNoneNoneFalseNoneFalse115485.79680
3429590121522Noneitem_code11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2 2023-24)Sqm303.85303.85187.56FalseNoneNoneFalseNoneFalse56990.1060
3429591121522Noneitem_code12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2 2023-24)Kgs116.39116.396130.0FalseNoneNoneFalseNoneFalse713470.70
3429592121522Noneitem_code13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2 2023-24)Sqm585.04585.04518.21FalseNoneNoneFalseNoneFalse303173.57840
3429593121522Noneitem_code14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2 2023-24)Sqm103.0103.0187.56FalseNoneNoneFalseNoneFalse19318.680
3429594121522Noneitem_code15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2 2023-24)Sqm75.1975.1991.08FalseNoneNoneFalseNoneFalse6848.30520
3429595121522Noneitem_code16KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2 2023-24)Sqm75.1975.1991.08FalseNoneNoneFalseNoneFalse6848.30520
3429596121522Noneitem_code17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2 2023-24)Sqm2711.992711.999.0FalseNoneNoneFalseNoneFalse24407.910
3429597121522Noneitem_code18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2 2023-24)Each25426.5825426.581.0FalseNoneNoneFalseNoneFalse25426.580
3429598121522Noneitem_code19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2 2023-24)Kg465.56465.56240.0FalseNoneNoneFalseNoneFalse111734.40
3429599121522Noneitem_code20Fabricating supplying and mounting MSboxmade out ....SWG suitableforfloor /wallmounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof lockingarrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete. PWD Ele SR 2-23-24 Page No 20 I No 5.42.2 16 SWGSq CM0.450.4543000.0FalseNoneNoneFalseNoneFalse19350.00
3429600121522Noneitem_code21Supplying and fixing Moulded Case Circui t Breaker (M CCB) overthe existing wood/panel board screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Over loadand Short circuit with adjustable the rmal magnetic release Microprocessor release shall have EarthFaultasperIS/IEC60947-2.(Icu=100%lcs). In4PMCCB, all Poles shouldhaveprotection forShort-Cicrcuit/OverLoad. ForMicroprocesso rMCCBS Facility for segregating Priority and Non-Priority loads must beavailable in theMCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits toavoidanyaccidentalcontactwith live current carryingpathwith the front cover open) Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. PWD ELE SR 2023-24 Page No 17 I No 5.15.9 100 A 25 kA Four PoleEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3429601121522Noneitem_code22Aluminium Busbar/Wire Pieces. ESCOM SR 2023-24 Page No 33 I No 69.04Kgs142.8142.80.5FalseNoneNoneFalseNoneFalse71.40
3429602121522Noneitem_code23Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.611.0FalseNoneNoneFalseNoneFalse26703.60
3429603121522Noneitem_code24Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3429604121522Noneitem_code25Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5511.0FalseNoneNoneFalseNoneFalse3361.050
3429605121522Noneitem_code26Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.1 6A TO 16 AEach345.45345.4510.0FalseNoneNoneFalseNoneFalse3454.50
3429606121522Noneitem_code27SUB PANEL :Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 withShort circuitbreakingcapacity of 10 Kandcomplete wiring as required confirming to IEC60898 PWD ELE SR PAGE NO 17 I NO : 5.18.9 50-63 A TPNEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3429607121522Noneitem_code28Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.610.0FalseNoneNoneFalseNoneFalse24276.00
3429608121522Noneitem_code29Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3429609121522Noneitem_code30Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5510.0FalseNoneNoneFalseNoneFalse3055.50
3429610121522Noneitem_code31Outgoings: 32A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.2Each575.48575.482.0FalseNoneNoneFalseNoneFalse1150.960
3429611121522Noneitem_code32Outgoings: 16A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.1Each407.15407.152.0FalseNoneNoneFalseNoneFalse814.30
3429612121522Noneitem_code331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32, 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Mtr187.92187.9230.0FalseNoneNoneFalseNoneFalse5637.60
3429613121522Noneitem_code341.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32, 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Mtr188.84188.8420.0FalseNoneNoneFalseNoneFalse3776.80
3429614121522Noneitem_code351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32,16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Mtr148.93148.9320.0FalseNoneNoneFalseNoneFalse2978.60
3429615121522Noneitem_code361.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32, 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Mtr123.9123.920.0FalseNoneNoneFalseNoneFalse2478.00
3429616121522Noneitem_code37Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 4Cx6.0 Sqmm Cu Ar cable ,3Cx6.0 Sqmm Cu Un Ar cable 3Cx 4.00 Sqmm ESCOM Page No 52 I NO 21.05Mtr21.9321.9350.0FalseNoneNoneFalseNoneFalse1096.50
3429617121522Noneitem_code38Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr72.4572.4510.0FalseNoneNoneFalseNoneFalse724.50
3429618121522Noneitem_code39Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.25mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr85.0585.0510.0FalseNoneNoneFalseNoneFalse850.50
3429619121522Noneitem_code40Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.32mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr111.3111.310.0FalseNoneNoneFalseNoneFalse1113.00
3429620121522Noneitem_code41Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.40mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr156.45156.4510.0FalseNoneNoneFalseNoneFalse1564.50
3429621121522Noneitem_code42Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.9519.95300.0FalseNoneNoneFalseNoneFalse5985.00
3429622121522Noneitem_code43Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr27.327.3300.0FalseNoneNoneFalseNoneFalse8190.00
3429623121522Noneitem_code44Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.2.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr44.144.1300.0FalseNoneNoneFalseNoneFalse13230.00
3429624121522Noneitem_code45Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.4 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr52.552.550.0FalseNoneNoneFalseNoneFalse2625.00
3429625121522Noneitem_code46Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.6 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr52.552.51.0FalseNoneNoneFalseNoneFalse52.50
3429626121522Noneitem_code47Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5Nos299.25299.256.0FalseNoneNoneFalseNoneFalse1795.50
3429627121522Noneitem_code48Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos413.7413.74.0FalseNoneNoneFalseNoneFalse1654.80
3429628121522Noneitem_code49Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5Nos598.5598.52.0FalseNoneNoneFalseNoneFalse1197.00
3429629121522Noneitem_code50Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos743.4743.41.0FalseNoneNoneFalseNoneFalse743.40
3429630121522Noneitem_code51Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos757.05757.051.0FalseNoneNoneFalseNoneFalse757.050
3429631121522Noneitem_code52Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.3 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1086.751086.753.0FalseNoneNoneFalseNoneFalse3260.250
3429632121522Noneitem_code53Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos107.1107.14.0FalseNoneNoneFalseNoneFalse428.40
3429633121522Noneitem_code54Switches & sockets outlets in Existing modular box 6A Three Way 5 Pin Socket CSR Electrical SR-2023-24, ITEM NO:3.14.3 ,CH-3, PAGE NO-10Nos73.573.52.0FalseNoneNoneFalseNoneFalse147.00
3429634121522Noneitem_code55Switches & sockets outlets in Existing modular box Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9Nos374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
3429635121522Noneitem_code56Switches & sockets outlets in Existing modular box 6/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3429636121522Noneitem_code57SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenanceof70 maximumlightintensityshouldbebetween 60degrees to 70degrees. CCT5500K, IP66optical andelectrical compartment and impact resistanceof complete luminaire IK08. Power Factor 0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbeEngraved /Embossing on thediecast housing/Bodypart.Warrantyof2Yearsagainstanymanufacturindefectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/Lumileds/Osram make LED Source CSR Electrical SR-2023-24, ITEM NO:11.8.2, PAGE NO-46Nos4225.24225.210.0FalseNoneNoneFalseNoneFalse42252.00
3429637121522Noneitem_code58Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Volume - V Water supply SR 2023-24Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3429638121522Noneitem_code59Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) VOL-6 KPTCL PG NO 120 . I no 22Mtr791.7791.720.0FalseNoneNoneFalseNoneFalse15834.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17198413720001NoneNoneELIGIBILITYNot applicableNone
17198413720001NoneNoneELIGIBILITYNot applicableNone
17198413720001NoneNoneELIGIBILITYNot applicableNone
17198413720000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17198413720000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSimilar nature of work done certificate of not less than Rs.15.00lakhs in any one of the last five yearsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBankers certificate of not less than Rs.9.00lakhs in the prescribed formatCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAverage annual financial turn over certificate of not less than the estimate cost of Rs.30.00lakhs in any two of the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneValid PWD registration certificateOthersValid PWD registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid GST Registration copyOthersGST Registration copy
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
NoneNoneNoneNoneNot applicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not applicable
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Upload all documents as per technical qualification criteria and bid documentTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksVijayanagaraKotturuNoneNoneTP Kottur limitNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone