tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719815064000 | 0 | None | None | Buildings | Avalahalli - Civil Works | 2002195.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3422942 | 121165 | None | code01 | Demolishing brick work manually/ by mechanical means including stacking of serviceable Material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 1250.65 | 1250.65 | 2.0 | False | None | None | False | None | False | 2501.3 | 0 | 3422943 | 121165 | None | code02 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 219.99 | 219.99 | 36.0 | False | None | None | False | None | False | 7919.64 | 0 | 3422944 | 121165 | None | code03 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 58.34 | 58.34 | 72.0 | False | None | None | False | None | False | 4200.48 | 0 | 3422945 | 121165 | None | code04 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 1250.65 | 1250.65 | 6.0 | False | None | None | False | None | False | 7503.9 | 0 | 3422946 | 121165 | None | code05 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 120.32 | 120.32 | 2070.0 | False | None | None | False | None | False | 249062.4 | 0 | 3422947 | 121165 | None | code06 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coat applied @ 1.67 ltr/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerin- charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 127.62 | 127.62 | 1058.0 | False | None | None | False | None | False | 135021.96 | 0 | 3422948 | 121165 | None | code07 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800x800 mm (P.61/9.17.3/V.2) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1579.86 | 1579.86 | 39.0 | False | None | None | False | None | False | 61614.54 | 0 | 3422949 | 121165 | None | code08 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 3500.98 | 3500.98 | 34.0 | False | None | None | False | None | False | 119033.32 | 0 | 3422950 | 121165 | None | code09 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1761.11 | 1761.11 | 81.0 | False | None | None | False | None | False | 142649.91 | 0 | 3422951 | 121165 | None | code10 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality on forming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1091.3 | 1091.3 | 30.0 | False | None | None | False | None | False | 32739.0 | 0 | 3422952 | 121165 | None | code11 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 120099.75 | 120099.75 | 0.1 | False | None | None | False | None | False | 12009.975 | 0 | 3422953 | 121165 | None | code12 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 1234.85 | 1234.85 | 2.0 | False | None | None | False | None | False | 2469.7 | 0 | 3422954 | 121165 | None | code13 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification. -do- 30 mm thick both side Teak ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 4913.86 | 4913.86 | 2.5 | False | None | None | False | None | False | 12284.65 | 0 | 3422955 | 121165 | None | code14 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Rmtr | 853.21 | 853.21 | 20.4 | False | None | None | False | None | False | 17405.484 | 0 | 3422956 | 121165 | None | code15 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (SR-2023-24, 12.94.1,P-112) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 4235.67 | 4235.67 | 7.5 | False | None | None | False | None | False | 31767.525 | 0 | 3422957 | 121165 | None | code16 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 8184.5 | 8184.5 | 29.0 | False | None | None | False | None | False | 237350.5 | 0 | 3422958 | 121165 | None | code17 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per pecification.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 895.75 | 895.75 | 33.0 | False | None | None | False | None | False | 29559.75 | 0 | 3422959 | 121165 | None | code18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 2475.98 | 2475.98 | 10.0 | False | None | None | False | None | False | 24759.8 | 0 | 3422960 | 121165 | None | code19 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7631.7 | 7631.7 | 6.0 | False | None | None | False | None | False | 45790.2 | 0 | 3422961 | 121165 | None | code20 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(P-13/6.7,V-2) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 11615.58 | 11615.58 | 2.0 | False | None | None | False | None | False | 23231.16 | 0 | 3422962 | 121165 | None | code21 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 450.91 | 450.91 | 25.0 | False | None | None | False | None | False | 11272.75 | 0 | 3422963 | 121165 | None | code22 | Surface preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to give a tough elastomeric water proof membrane. System : providing and applying 1.2mm thick roller applied single component Bitumen Modified Polyurathene coating. NITOPROOF 600 or equivalent, having elongation capability of 450% as per ASTM D412, having Tensile strength 1.5 N/mm2 as per ASTM D412 , Tear Resistance of 15N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D2240. Waterproofing treatment to be provided after proper surface preparation as per manufacturer specification Protection of water proofing system with minimum 50mm thick screed and providing construction joints and sealing the same with PU sealant ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1593.0 | 1593.0 | 267.0 | False | None | None | False | None | False | 425331.0 | 0 | 3422964 | 121165 | None | code23 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 2057.67 | 2057.67 | 36.0 | False | None | None | False | None | False | 74076.12 | 0 | 3422965 | 121165 | None | code24 | Providing and fixing Veneer paneling, over the 50mm x 35mm sal wood frame work at spacing not exceeding 600mm c/c fixed to the wall and top covered out of 4mm thick approved quality Veneer, fixed over 12mm thick ply of approved brand, termite and water resistant, finished with melamine polish, complete including cost and conveyance of all materials, labour for all items of work HOM etc., complete as per specification. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 4764.98 | 4764.98 | 28.0 | False | None | None | False | None | False | 133419.44 | 0 | 3422966 | 121165 | None | code25 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1341.8 | 1341.8 | 6.0 | False | None | None | False | None | False | 8050.8 | 0 | 3422967 | 121165 | None | code26 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 5200.7 | 5200.7 | 8.0 | False | None | None | False | None | False | 41605.6 | 0 | 3422968 | 121165 | None | code27 | Providing full nosing for 40mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Rmtr | 688.18 | 688.18 | 14.0 | False | None | None | False | None | False | 9634.52 | 0 | 3422969 | 121165 | None | code28 | KSRB 7.15 : Providing, fabricating, assembling and fixing in position aluminium partitions using aluminium sections of mat finish or glassy finish in combination of plain grove, single grove and double grove as per requirements for the frames of overall size 63.5mm x 38.1mm. with thickness of 2mm. having section weight, plain sections 1.054kg/m,single grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm. x 44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvres section of size 36.5mmx34.93mm 1.45mm. thick section weight 0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet both sides of approved colour lamination exterior grade upto 0.9m height, spacing of vertical member not exceeding 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames; the assembled frame stiffened with corner angles, stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistelling and making good with cement mortar to match the surface; providing and fixing 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with louvres sections; the glass and panels fitted with glazing clips of 19mmx17.3mm. of thickness 0.9mm.weight 0.124kg/m, aluminium sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necessary opening for fixing of door of standard size (excluding cost of door ) all the frame thoroughly cleaned,free from rust, scale or dirt including cost of materials, fixtures, labour and HOM complete as per specifications.-do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 4373.74 | 4373.74 | 13.0 | False | None | None | False | None | False | 56858.62 | 0 | 3422970 | 121165 | None | code29 | KSRB 7.16 : Providing, fabricating, assembling and fixing in position aluminium shutters to the existing door frame in the partition using 47.62x44.45mm section thickness 3.18mm, weight 1.505kg/m for vertical frame; 47.62x44.45 thickness of 3mm, weight 1.42kg/m for top section, 49.91mmx44.45mm with wall thickness 3mm, weight 1.495kg/m for central rail; and 114.3mmx44.45mm thickness 3.18mm, weight 2.646kg/m for bottom rail; aluminium sections and cut to length joint metred and corners grinded, the bottom rail and top rail hinged or pivoted,opening arrangements including providing and fixing standard approved accessories, such as aluminium handles, tower bolts, lock, pivots: hinges P.V.C. or rubber gasket, 12mm prelaminated sheets (Novopan) exterior grade of approved colour both sides same colour for bottom panel of maximum height 0.90m and 5.5mm thick plain glass for top panel (Novopan) and glass fixed with glazed clips 19mmx17.3mmx11mm,0.9mm thick, weight 0.124kg/m; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials,including cost of materials, fixtures, labour and HOM complete as per specifications. -do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (Old SR.P.38/7.16.2) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 5120.54 | 5120.54 | 7.0 | False | None | None | False | None | False | 35843.78 | 0 | 3422971 | 121165 | None | code30 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1121.47 | 1121.47 | 4.0 | False | None | None | False | None | False | 4485.88 | 0 | 3422972 | 121165 | None | code31 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 14 m3) Cost of Haulage Excluding Loading and Unloading ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 109.69 | 109.69 | 25.0 | False | None | None | False | None | False | 2742.25 | 0 |
| 1719815064000 | 0 | None | None | Buildings | Avalahalli - Water supply works | 172828.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3422973 | 121166 | None | code01 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 type A, including jointing with seal ring conforming to IS; 5382, Leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 353.68 | 353.68 | 40.0 | False | None | None | False | None | False | 14147.2 | 0 | 3422974 | 121166 | None | code02 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work,including cutting chases and making good the walls etc. 15mm nominal dia pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 375.56 | 375.56 | 20.0 | False | None | None | False | None | False | 7511.2 | 0 | 3422975 | 121166 | None | code03 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work,including cutting chases and making good the walls etc. 25mm nominal dia pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 579.75 | 579.75 | 20.0 | False | None | None | False | None | False | 11595.0 | 0 | 3422976 | 121166 | None | code04 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work,including cutting chases and making good the walls etc. 20mm nominal dia pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 460.64 | 460.64 | 20.0 | False | None | None | False | None | False | 9212.8 | 0 | 3422977 | 121166 | None | code05 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 5 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Rmtr | 122.76 | 122.76 | 25.0 | False | None | None | False | None | False | 3069.0 | 0 | 3422978 | 121166 | None | code06 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Rmtr | 267.39 | 267.39 | 20.0 | False | None | None | False | None | False | 5347.8 | 0 | 3422979 | 121166 | None | code07 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mmr ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 353.68 | 353.68 | 50.0 | False | None | None | False | None | False | 17684.0 | 0 | 3422980 | 121166 | None | code08 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 4185.84 | 4185.84 | 8.0 | False | None | None | False | None | False | 33486.72 | 0 | 3422981 | 121166 | None | code09 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 7264.45 | 7264.45 | 4.0 | False | None | None | False | None | False | 29057.8 | 0 | 3422982 | 121166 | None | code10 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 1153.41 | 1153.41 | 3.0 | False | None | None | False | None | False | 3460.23 | 0 | 3422983 | 121166 | None | code11 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 2850.11 | 2850.11 | 4.0 | False | None | None | False | None | False | 11400.44 | 0 | 3422984 | 121166 | None | code12 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 1028.23 | 1028.23 | 8.0 | False | None | None | False | None | False | 8225.84 | 0 | 3422985 | 121166 | None | code13 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 753.55 | 753.55 | 4.0 | False | None | None | False | None | False | 3014.2 | 0 | 3422986 | 121166 | None | code14 | Providing and fixing unplasticised PVC connection pipe with brass unions .20 mm nominal bore ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 133.69 | 133.69 | 14.0 | False | None | None | False | None | False | 1871.66 | 0 | 3422987 | 121166 | None | code15 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 111.82 | 111.82 | 8.0 | False | None | None | False | None | False | 894.56 | 0 | 3422988 | 121166 | None | code16 | Supplying and fixing "JAQUAR" make, ALLIED series, C.P.Health Faucet Cat No.ALD-573 with 1.00m tube and hook including necessary screws, accessories etc, complete, including cost of all materials, labour charges, with all lead and lift, loading and unloading, transportation, machineries and all other incidental charges for successful completion of the work as per directions of the Engineer-in-charge of the work. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 2141.7 | 2141.7 | 6.0 | False | None | None | False | None | False | 12850.2 | 0 |
| 1719815064000 | 0 | None | None | Buildings | Avalahalli - Electrification Works | 818922.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3422989 | 121167 | None | code01 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet Short point upto 3m from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 336.3 | 336.3 | 3.0 | False | None | None | False | None | False | 1008.9 | 0 | 3422990 | 121167 | None | code02 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet Medium point above 3m upto 6m from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 464.92 | 464.92 | 4.0 | False | None | None | False | None | False | 1859.68 | 0 | 3422991 | 121167 | None | code03 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2(Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Point | 672.6 | 672.6 | 6.0 | False | None | None | False | None | False | 4035.6 | 0 | 3422992 | 121167 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 mm2 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 30.68 | 30.68 | 100.0 | False | None | None | False | None | False | 3068.0 | 0 | 3422993 | 121167 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 mm2 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 49.56 | 49.56 | 200.0 | False | None | None | False | None | False | 9912.0 | 0 | 3422994 | 121167 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 74.34 | 74.34 | 180.0 | False | None | None | False | None | False | 13381.2 | 0 | 3422995 | 121167 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 6 mm2 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 108.56 | 108.56 | 120.0 | False | None | None | False | None | False | 13027.2 | 0 | 3422996 | 121167 | None | code08 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 10 mm2 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 197.06 | 197.06 | 50.0 | False | None | None | False | None | False | 9853.0 | 0 | 3422997 | 121167 | None | code09 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 1-3 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 162.84 | 162.84 | 12.0 | False | None | None | False | None | False | 1954.08 | 0 | 3422998 | 121167 | None | code10 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 6 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3422999 | 121167 | None | code11 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 259.6 | 259.6 | 6.0 | False | None | None | False | None | False | 1557.6 | 0 | 3423000 | 121167 | None | code12 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3423001 | 121167 | None | code13 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 16-18 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3423002 | 121167 | None | code14 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 120.36 | 120.36 | 6.0 | False | None | None | False | None | False | 722.16 | 0 | 3423003 | 121167 | None | code15 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 201.78 | 201.78 | 8.0 | False | None | None | False | None | False | 1614.24 | 0 | 3423004 | 121167 | None | code16 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 421.26 | 421.26 | 8.0 | False | None | None | False | None | False | 3370.08 | 0 | 3423005 | 121167 | None | code17 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 212.4 | 212.4 | 6.0 | False | None | None | False | None | False | 1274.4 | 0 | 3423006 | 121167 | None | code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 278.48 | 278.48 | 4.0 | False | None | None | False | None | False | 1113.92 | 0 | 3423007 | 121167 | None | code19 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 184.08 | 184.08 | 2.0 | False | None | None | False | None | False | 368.16 | 0 | 3423008 | 121167 | None | code20 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45/I.O Outlet Cat-6 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 397.66 | 397.66 | 2.0 | False | None | None | False | None | False | 795.32 | 0 | 3423009 | 121167 | None | code21 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu 100% lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 7181.48 | 7181.48 | 1.0 | False | None | None | False | None | False | 7181.48 | 0 | 3423010 | 121167 | None | code22 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3423011 | 121167 | None | code23 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 547.52 | 547.52 | 2.0 | False | None | None | False | None | False | 1095.04 | 0 | 3423012 | 121167 | None | code24 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 2612.52 | 2612.52 | 4.0 | False | None | None | False | None | False | 10450.08 | 0 | 3423013 | 121167 | None | code25 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 3632.04 | 3632.04 | 2.0 | False | None | None | False | None | False | 7264.08 | 0 | 3423014 | 121167 | None | code26 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 80.24 | 80.24 | 80.0 | False | None | None | False | None | False | 6419.2 | 0 | 3423015 | 121167 | None | code27 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 25 mm dia 2 mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 94.4 | 94.4 | 70.0 | False | None | None | False | None | False | 6608.0 | 0 | 3423016 | 121167 | None | code28 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 32 mm dia 2.5 mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 118.0 | 118.0 | 40.0 | False | None | None | False | None | False | 4720.0 | 0 | 3423017 | 121167 | None | code29 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 501.5 | 501.5 | 15.0 | False | None | None | False | None | False | 7522.5 | 0 | 3423018 | 121167 | None | code30 | Supplying and drawing UTP-CAT 6E LAN cable. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 34.22 | 34.22 | 30.0 | False | None | None | False | None | False | 1026.6 | 0 | 3423019 | 121167 | None | code31 | Supplying and drawing UTP-CAT 6E LAN cable Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable-2Pair ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 17.11 | 17.11 | 400.0 | False | None | None | False | None | False | 6844.0 | 0 | 3423020 | 121167 | None | code32 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48 Sweep (1200 mm) Regular model ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 2460.3 | 2460.3 | 8.0 | False | None | None | False | None | False | 19682.4 | 0 | 3423021 | 121167 | None | code33 | Supplying of .....feet PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4 - 20/22 W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 814.2 | 814.2 | 7.0 | False | None | None | False | None | False | 5699.4 | 0 | 3423022 | 121167 | None | code34 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4 - 36/40 W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 1497.42 | 1497.42 | 8.0 | False | None | None | False | None | False | 11979.36 | 0 | 3423023 | 121167 | None | code35 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2' /1'x4' 34-36 W- ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 6959.64 | 6959.64 | 6.0 | False | None | None | False | None | False | 41757.84 | 0 | 3423024 | 121167 | None | code36 | Supplying 10 litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 8925.52 | 8925.52 | 2.0 | False | None | None | False | None | False | 17851.04 | 0 | 3423025 | 121167 | None | code37 | Supplying exhaust fan of 1440 RPM of 300 mm (12) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 1760.56 | 1760.56 | 4.0 | False | None | None | False | None | False | 7042.24 | 0 | 3423026 | 121167 | None | code38 | Supplying of 1.5 Ton capacity window type air conditioner confirming to IS specification suitable for operation on 230 V,50 Hz single phase, AC. supply with all accessories. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 37571.2 | 37571.2 | 2.0 | False | None | None | False | None | False | 75142.4 | 0 | 3423027 | 121167 | None | code39 | Supply & Installation DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 Kg WL ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 44554.44 | 44554.44 | 1.0 | False | None | None | False | None | False | 44554.44 | 0 | 3423028 | 121167 | None | code40 | Supply & Installation 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 260.78 | 260.78 | 3.0 | False | None | None | False | None | False | 782.34 | 0 | 3423029 | 121167 | None | code41 | Supply & Installation 11 kV, 45 KN Polymeric Insulator ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 238.36 | 238.36 | 3.0 | False | None | None | False | None | False | 715.08 | 0 | 3423030 | 121167 | None | code42 | Supply & Installation Guy Set Complete with No. 15 Strain Insulator &
Concreting materials ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 1955.26 | 1955.26 | 4.0 | False | None | None | False | None | False | 7821.04 | 0 | 3423031 | 121167 | None | code43 | Supply & Installation 11kV /433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with Oil ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 209001.6 | 209001.6 | 1.0 | False | None | None | False | None | False | 209001.6 | 0 | 3423032 | 121167 | None | code44 | Supply & Installation Earthing materials pipe type for grounding (Single Electrode with accessories) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 2900.44 | 2900.44 | 3.0 | False | None | None | False | None | False | 8701.32 | 0 | 3423033 | 121167 | None | code45 | Supply & Installation Caution/Danger Board ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 244.26 | 244.26 | 1.0 | False | None | None | False | None | False | 244.26 | 0 | 3423034 | 121167 | None | code46 | Supply & Installation Anti Climbing Device (12 Mtr GI Barbed Wire) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 147.5 | 147.5 | 2.0 | False | None | None | False | None | False | 295.0 | 0 | 3423035 | 121167 | None | code47 | Supply & Installation Guy concreting with Boulders, Mud and Sand ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 | 3423036 | 121167 | None | code48 | Supply & Installation GI Wire 8 SWG ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 91.86 | 91.86 | 10.0 | False | None | None | False | None | False | 918.6 | 0 | 3423037 | 121167 | None | code49 | Supply & Installation Guy wire 7 / 10 SWG ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Kg | 94.54 | 94.54 | 15.0 | False | None | None | False | None | False | 1418.1 | 0 | 3423038 | 121167 | None | code50 | Supply & Installation 11 kV Lightning Arrester, Metal Oxide
9 kV, 5 kA, Polymetic type with ground disconnector ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 2154.68 | 2154.68 | 1.0 | False | None | None | False | None | False | 2154.68 | 0 | 3423039 | 121167 | None | code51 | Supply & Installation a) LT Protection Kit for 63 kVA
b) LT Wiring (From OTC to LT Line Through
Metering Box & LT Protection Kit) SINGLE CIRCUIT ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 2566.5 | 2566.5 | 2.0 | False | None | None | False | None | False | 5133.0 | 0 | 3423040 | 121167 | None | code52 | Supply & Installation i) Al Lead Wire - 95 Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 176.74 | 176.74 | 80.0 | False | None | None | False | None | False | 14139.2 | 0 | 3423041 | 121167 | None | code53 | Supply & Installation ii) Heavy Duty Long Barrel Copper Lug - 95
Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 156.94 | 156.94 | 4.0 | False | None | None | False | None | False | 627.76 | 0 | 3423042 | 121167 | None | code54 | Supply & Installation iii) PG Clamp - Rabbit to 95 Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 187.62 | 187.62 | 4.0 | False | None | None | False | None | False | 750.48 | 0 | 3423043 | 121167 | None | code55 | Supply & Installation iv) Spacer for OTC Wiring ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 48.38 | 48.38 | 8.0 | False | None | None | False | None | False | 387.04 | 0 | 3423044 | 121167 | None | code56 | Supply & Installation v) Fish Plate with necessary Clamps, bolts &
nuts etc complete (Galvanised) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 270.22 | 270.22 | 2.0 | False | None | None | False | None | False | 540.44 | 0 | 3423045 | 121167 | None | code57 | Supply & Installation c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS - 39) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 7349.04 | 7349.04 | 1.0 | False | None | None | False | None | False | 7349.04 | 0 | 3423046 | 121167 | None | code58 | Supply & Installation d) LT Electronic Tri-Vector Meter 5 Amps, -0.5/ 1.0 Accuracy Class ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | No | 4849.8 | 4849.8 | 1.0 | False | None | None | False | None | False | 4849.8 | 0 | 3423047 | 121167 | None | code59 | Supply & Installation 11 kV, Solid Core Type HG Fuse Unit ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 1427.8 | 1427.8 | 1.0 | False | None | None | False | None | False | 1427.8 | 0 | 3423048 | 121167 | None | code60 | Supply & Installation 11 kV, 200 Amps, Single Break GOS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Set | 11717.4 | 11717.4 | 1.0 | False | None | None | False | None | False | 11717.4 | 0 | 3423049 | 121167 | None | code61 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 512.12 | 512.12 | 3.0 | False | None | None | False | None | False | 1536.36 | 0 | 3423050 | 121167 | None | code62 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 4897.0 | 4897.0 | 4.0 | False | None | None | False | None | False | 19588.0 | 0 | 3423051 | 121167 | None | code63 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 135.7 | 135.7 | 60.0 | False | None | None | False | None | False | 8142.0 | 0 | 3423052 | 121167 | None | code64 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm GI strip ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 188.8 | 188.8 | 25.0 | False | None | None | False | None | False | 4720.0 | 0 | 3423053 | 121167 | None | code65 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 3.5 core 95 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 572.3 | 572.3 | 100.0 | False | None | None | False | None | False | 57230.0 | 0 | 3423054 | 121167 | None | code66 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct . 95 sqmm to 150Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 24.78 | 24.78 | 60.0 | False | None | None | False | None | False | 1486.8 | 0 | 3423055 | 121167 | None | code67 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall /Structure . 95 sqmm to 150Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 47.2 | 47.2 | 40.0 | False | None | None | False | None | False | 1888.0 | 0 | 3423056 | 121167 | None | code68 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7). n soil (ordinary) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 89.68 | 89.68 | 60.0 | False | None | None | False | None | False | 5380.8 | 0 | 3423057 | 121167 | None | code69 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7). Cutting road surface ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 96.76 | 96.76 | 10.0 | False | None | None | False | None | False | 967.6 | 0 | 3423058 | 121167 | None | code70 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 118.0 | 118.0 | 60.0 | False | None | None | False | None | False | 7080.0 | 0 | 3423059 | 121167 | None | code71 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 80mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 811.84 | 811.84 | 10.0 | False | None | None | False | None | False | 8118.4 | 0 | 3423060 | 121167 | None | code72 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 50mm dia ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 300.9 | 300.9 | 2.0 | False | None | None | False | None | False | 601.8 | 0 | 3423061 | 121167 | None | code73 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.50 sqmm Long Barrel ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 70.8 | 70.8 | 2.0 | False | None | None | False | None | False | 141.6 | 0 | 3423062 | 121167 | None | code74 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.95 sqmm Long Barrel ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 171.1 | 171.1 | 6.0 | False | None | None | False | None | False | 1026.6 | 0 | 3423063 | 121167 | None | code75 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics). FOUR POLE. 100Amps 25kA ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 7552.0 | 7552.0 | 1.0 | False | None | None | False | None | False | 7552.0 | 0 | 3423064 | 121167 | None | code76 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3423065 | 121167 | None | code77 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Each | 552.24 | 552.24 | 1.0 | False | None | None | False | None | False | 552.24 | 0 | 3423066 | 121167 | None | code78 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 507.4 | 507.4 | 3.0 | False | None | None | False | None | False | 1522.2 | 0 | 3423067 | 121167 | None | code79 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 2419.0 | 2419.0 | 10.0 | False | None | None | False | None | False | 24190.0 | 0 | 3423068 | 121167 | None | code80 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Mtr | 300.9 | 300.9 | 5.0 | False | None | None | False | None | False | 1504.5 | 0 | 3423069 | 121167 | None | code81 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sq CM | 0.47 | 0.47 | 25000.0 | False | None | None | False | None | False | 11750.0 | 0 |
| 1719815064000 | 1 | None | None | Buildings | Kodathi Civil Work | 794835.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3423070 | 121168 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 1363.67 | 1363.67 | 1.03 | False | None | None | False | None | False | 1404.5801 | 0 | 3423071 | 121168 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 115.46 | 115.46 | 40.03 | False | None | None | False | None | False | 4621.8638 | 0 | 3423072 | 121168 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 123.97 | 123.97 | 102.06 | False | None | None | False | None | False | 12652.3782 | 0 | 3423073 | 121168 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 516.54 | 516.54 | 6.05 | False | None | None | False | None | False | 3125.067 | 0 | 3423074 | 121168 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 441.19 | 441.19 | 6.05 | False | None | None | False | None | False | 2669.1995 | 0 | 3423075 | 121168 | None | code06 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 143.41 | 143.41 | 89.74 | False | None | None | False | None | False | 12869.6134 | 0 | 3423076 | 121168 | None | code07 | Mix 1:3:6 (M10): Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 7279.03 | 7279.03 | 5.16 | False | None | None | False | None | False | 37559.7948 | 0 | 3423077 | 121168 | None | code08 | M25 Design Mix Using 20 mm :Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates BOTTOM SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 9196.07 | 9196.07 | 12.28 | False | None | None | False | None | False | 112927.7396 | 0 | 3423078 | 121168 | None | code10 | M25 Design Mix Using 20 mm :Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TOP SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 9196.07 | 9196.07 | 3.08 | False | None | None | False | None | False | 28323.8956 | 0 | 3423079 | 121168 | None | code12 | M25 Design Mix Using 20 mm :Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 8448.42 | 8448.42 | 14.98 | False | None | None | False | None | False | 126557.3316 | 0 | 3423080 | 121168 | None | code12 | M25 Design Mix Using 20 mm :Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL - centering charges ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Cum | 971.94 | 971.94 | 1.0 | False | None | None | False | None | False | 971.94 | 0 | 3423081 | 121168 | None | code13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Tonne | 96029.96 | 96029.96 | 2.64 | False | None | None | False | None | False | 253519.0944 | 0 | 3423082 | 121168 | None | code14 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 403% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 992.98 | 992.98 | 99.16 | False | None | None | False | None | False | 98463.8968 | 0 | 3423083 | 121168 | None | code15 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 392.57 | 392.57 | 20.56 | False | None | None | False | None | False | 8071.2392 | 0 | 3423084 | 121168 | None | code16 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 430.25 | 430.25 | 157.2 | False | None | None | False | None | False | 67635.3 | 0 | 3423085 | 121168 | None | code17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Sqm | 139.77 | 139.77 | 41.12 | False | None | None | False | None | False | 5747.3424 | 0 | 3423086 | 121168 | None | code18 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | m | 499.52 | 499.52 | 20.0 | False | None | None | False | None | False | 9990.4 | 0 | 3423087 | 121168 | None | code19 | C. I Manhole covers 24 x 24 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work | Nos | 2574.99 | 2574.99 | 3.0 | False | None | None | False | None | False | 7724.97 | 0 |
|
|
---|