createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719918917710
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd49700.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-07-2024 16:00:00
tenderQueryClose10-07-2024 11:00:00
technicalBidOpen16-07-2024 16:00:01
publishedDate03-07-2024 15:35:57
publishedByPostEWHFWD_EE_EEOFF_BNG
publishedByUserKPE21346 - NAGARAJ MANGAL BORALINGAIAH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSri. Umesh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08162251895
mobileNumber8147871788
tenderSupplierListNone
tenderSchedule
createdTs1719918917737
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT519
titleConstruction of Block Level Public Health Unit on existing TLH at TLH Hiriyur in Chitradurga District
descriptionConstruction of Block Level Public Health Unit on existing TLH at TLH Hiriyur in Chitradurga District
categoryWORKS
categoryTextWorks
ecv4961670.35
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3522
locationNameEWHFWD Executive Engineer Office Bengaluru
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumberAEE/HFWD/CHITRADURGA/HIRIYUR/BPHU/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17199189180000NoneNoneBuildingsConstruction of Block Level Public Health Unit on existing TLH at TLH Hiriyur in Chitradurga District4961670.35
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3436082121804NoneV 3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm491.56491.562.1749FalseNoneNoneFalseNoneFalse1069.0938440
3436083121804NoneV 1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum118.83118.8365.247FalseNoneNoneFalseNoneFalse7753.301010
3436084121804NoneV 1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum127.58127.5894.8915FalseNoneNoneFalseNoneFalse12106.257570
3436085121804NoneV 1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum454.04454.049.7755FalseNoneNoneFalseNoneFalse4438.468020
3436086121804NoneV 3 Item No 1.1 (a)Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Tipper 5.5 Cum ) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum168.86168.8659.7755FalseNoneNoneFalseNoneFalse10093.690930
3436087121804NoneV 2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm147.59147.59182.35FalseNoneNoneFalseNoneFalse26913.03650
3436088121804NoneV 1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum332.71332.7195.6595FalseNoneNoneFalseNoneFalse31826.8722450
3436089121804NoneV 1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum592.88592.8861.242FalseNoneNoneFalseNoneFalse36309.156960
3436090121804NoneV 1 Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum7491.047491.0422.59FalseNoneNoneFalseNoneFalse169222.59360
3436091121804NoneV 1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOOTINGS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum8541.148541.1417.253FalseNoneNoneFalseNoneFalse147360.288420
3436092121804NoneV 1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTALS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum8695.158695.152.5875FalseNoneNoneFalseNoneFalse22498.7006250
3436093121804NoneV 1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMNS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum14381.1114381.119.0045FalseNoneNoneFalseNoneFalse129494.7049950
3436094121804NoneV 1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM and RCC SLAB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum12717.7212717.7237.6105FalseNoneNoneFalseNoneFalse478319.808060
3436095121804NoneV 1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS and LINTELS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum13549.4113549.4113.1759FalseNoneNoneFalseNoneFalse178525.6712190
3436096121804NoneV 1 Item No 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum11176.4911176.493.3469FalseNoneNoneFalseNoneFalse37406.5943810
3436097121804NoneV 3 Item No 15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNo255.16255.1610.0FalseNoneNoneFalseNoneFalse2551.60
3436098121804NoneV 2 Item No 8.16aKSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1548.491548.494.5FalseNoneNoneFalseNoneFalse6968.2050
3436099121804NoneV 1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workTonne111892.82111892.826.686FalseNoneNoneFalseNoneFalse748115.394520
3436100121804None2018-19 SR Item No 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr41.2841.2854.0FalseNoneNoneFalseNoneFalse2229.120
3436101121804NoneApproved Data RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr91.3191.3154.0FalseNoneNoneFalseNoneFalse4930.740
3436102121804NoneV 2 Item No 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum7991.367991.361.62FalseNoneNoneFalseNoneFalse12946.00320
3436103121804NoneV 2 Item No 6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1539.731539.73164.48FalseNoneNoneFalseNoneFalse253254.79040
3436104121804NoneV 2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1380.881380.8867.326FalseNoneNoneFalseNoneFalse92969.126880
3436105121804NoneV 2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workCum123597.8123597.80.689FalseNoneNoneFalseNoneFalse85158.88420
3436106121804NoneV 2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos1270.811270.8112.0FalseNoneNoneFalseNoneFalse15249.720
3436107121804NoneV 2 Item No 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos1315.841315.8412.0FalseNoneNoneFalseNoneFalse15790.080
3436108121804NoneV 2 Item No 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos1238.291238.2912.0FalseNoneNoneFalseNoneFalse14859.480
3436109121804NoneV 2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos296.44296.4424.0FalseNoneNoneFalseNoneFalse7114.560
3436110121804NoneV 2 Item No 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos162.6162.624.0FalseNoneNoneFalseNoneFalse3902.40
3436111121804NoneV 2 Item No 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos68.7968.7912.0FalseNoneNoneFalseNoneFalse825.480
3436112121804NoneV 2 Item No 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos343.97343.9724.0FalseNoneNoneFalseNoneFalse8255.280
3436113121804NoneV 2 Item No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos75.0575.0572.0FalseNoneNoneFalseNoneFalse5403.60
3436114121804None2018-19 SR Item No 309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr15.8915.8977.6FalseNoneNoneFalseNoneFalse1233.0640
3436115121804NoneV 2 Item No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm4155.164155.1628.56FalseNoneNoneFalseNoneFalse118671.36960
3436116121804NoneV 2 Item No 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm8422.898422.8927.0FalseNoneNoneFalseNoneFalse227418.030
3436117121804NoneV 2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm7153.337153.331.44FalseNoneNoneFalseNoneFalse10300.79520
3436118121804NoneV 2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workKg210.13210.13597.24FalseNoneNoneFalseNoneFalse125498.04120
3436119121804NoneV 2 Item No 12.93Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)12.93.1 Size 62 x 100mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm878.06878.0619.8FalseNoneNoneFalseNoneFalse17385.5880
3436120121804NoneV 2 Item No 12.94Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 12.94.130 mm thickness ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm4359.044359.046.3FalseNoneNoneFalseNoneFalse27461.9520
3436121121804NoneV 2 Item No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos1393.391393.3912.0FalseNoneNoneFalseNoneFalse16720.680
3436122121804NoneV 2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm390.25390.25410.721FalseNoneNoneFalseNoneFalse160283.870250
3436123121804NoneV 2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm125.08125.08681.7985FalseNoneNoneFalseNoneFalse85279.356380
3436124121804NoneV 2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm367.74367.74280.5FalseNoneNoneFalseNoneFalse103151.070
3436125121804None2018-19 SR Item No 15.36KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr45.0345.03807.0FalseNoneNoneFalseNoneFalse36339.210
3436126121804None2018-19 SR Item No 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm300.19300.1910.0FalseNoneNoneFalseNoneFalse3001.90
3436127121804NoneV 2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr65.0465.04256.0FalseNoneNoneFalseNoneFalse16650.240
3436128121804NoneV 2 Item No 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1469.691469.69168.8FalseNoneNoneFalseNoneFalse248083.6720
3436129121804NoneV 2 Item No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm368.99368.9942.84FalseNoneNoneFalseNoneFalse15807.53160
3436130121804NoneV 2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm3084.473084.4735.268FalseNoneNoneFalseNoneFalse108783.087960
3436131121804NoneV 2 Item No 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed at 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm769.24769.248.34FalseNoneNoneFalseNoneFalse6415.46160
3436132121804NoneV 2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry at 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1111.961111.968.34FalseNoneNoneFalseNoneFalse9273.74640
3436133121804NoneV 2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1812.411812.4142.84FalseNoneNoneFalseNoneFalse77643.64440
3436134121804NoneV 2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm158.85158.85681.7985FalseNoneNoneFalseNoneFalse108303.6917250
3436135121804NoneV 2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied at 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm195.12195.12280.5FalseNoneNoneFalseNoneFalse54731.160
3436136121804NoneV 2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm62.5462.5428.44FalseNoneNoneFalseNoneFalse1778.63760
3436137121804NoneV 2 Item No 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm143.84143.8428.44FalseNoneNoneFalseNoneFalse4090.80960
3436138121804NoneV 2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm66.2966.2968.544FalseNoneNoneFalseNoneFalse4543.781760
3436139121804NoneV 2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at 150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm1031.841031.84172.0FalseNoneNoneFalseNoneFalse177476.480
3436140121804NoneV 5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workRmtr322.06322.0624.0FalseNoneNoneFalseNoneFalse7729.440
3436141121804NoneV 2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach111.82111.828.0FalseNoneNoneFalseNoneFalse894.560
3436142121804NoneV 5 Item No 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3436143121804NoneV 5 Item No 657PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm149.49149.4940.0FalseNoneNoneFalseNoneFalse5979.60
3436144121804NoneV 5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm309.93309.9335.0FalseNoneNoneFalseNoneFalse10847.550
3436145121804NoneV 2 Item No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3436146121804NoneV 2 Item No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach1482.791482.794.0FalseNoneNoneFalseNoneFalse5931.160
3436147121804NoneV 2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos7264.457264.454.0FalseNoneNoneFalseNoneFalse29057.80
3436148121804NoneV 2 Item No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3436149121804NoneV 2 Item No 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos881.17881.174.0FalseNoneNoneFalseNoneFalse3524.680
3436150121804NoneV 2 Item No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3436151121804NoneV 2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3436152121804NoneV 2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm460.64460.6445.0FalseNoneNoneFalseNoneFalse20728.80
3436153121804NoneV 2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3436154121804NoneV 2 Item No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workm359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3436155121804NoneV 5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3436156121804NoneV 2 Item No 13.58Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos420.53420.532.0FalseNoneNoneFalseNoneFalse841.060
3436157121804NoneV 2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workLtr10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3436158121804NoneV 2 Item No 14.95Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNos1019.721019.724.0FalseNoneNoneFalseNoneFalse4078.880
3436159121804NoneELECTRICAL Item No 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workPoint326.94326.9410.0FalseNoneNoneFalseNoneFalse3269.40
3436160121804NoneELECTRICAL Item No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workPoint460.64460.6412.0FalseNoneNoneFalseNoneFalse5527.680
3436161121804NoneELECTRICAL Item No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workPoint674.55674.5515.0FalseNoneNoneFalseNoneFalse10118.250
3436162121804NoneELECTRICAL Item No 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3436163121804NoneELECTRICAL Item No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach167.73167.735.0FalseNoneNoneFalseNoneFalse838.650
3436164121804NoneELECTRICAL Item No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
3436165121804NoneELECTRICAL Item No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3436166121804NoneELECTRICAL Item No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3436167121804NoneELECTRICAL Item No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3436168121804NoneELECTRICAL Item No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach387.71387.7114.0FalseNoneNoneFalseNoneFalse5427.940
3436169121804NoneELECTRICAL Item No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach166.51166.515.0FalseNoneNoneFalseNoneFalse832.550
3436170121804NoneELECTRICAL Item No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach195.68195.685.0FalseNoneNoneFalseNoneFalse978.40
3436171121804NoneELECTRICAL Item No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach212.7212.73.0FalseNoneNoneFalseNoneFalse638.10
3436172121804NoneELECTRICAL Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3436173121804NoneELECTRICAL Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3436174121804NoneELECTRICAL Item No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach418.1418.114.0FalseNoneNoneFalseNoneFalse5853.40
3436175121804NoneELECTRICAL Item No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach123.97123.9775.0FalseNoneNoneFalseNoneFalse9297.750
3436176121804NoneELECTRICAL Item No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach207.83207.8330.0FalseNoneNoneFalseNoneFalse6234.90
3436177121804NoneELECTRICAL Item No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach433.9433.910.0FalseNoneNoneFalseNoneFalse4339.00
3436178121804NoneELECTRICAL Item No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3436179121804NoneELECTRICAL Item No 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3436180121804NoneELECTRICAL Item No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3436181121804NoneELECTRICAL Item No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNo142.2142.210.0FalseNoneNoneFalseNoneFalse1422.00
3436182121804NoneELECTRICAL Item No 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr80.2280.22250.0FalseNoneNoneFalseNoneFalse20055.00
3436183121804NoneELECTRICAL Item No 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr94.894.8300.0FalseNoneNoneFalseNoneFalse28440.00
3436184121804NoneELECTRICAL Item No 1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr125.19125.1970.0FalseNoneNoneFalseNoneFalse8763.30
3436185121804NoneELECTRICAL Item No 1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr82.6582.65150.0FalseNoneNoneFalseNoneFalse12397.50
3436186121804NoneELECTRICAL Item No 1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3436187121804NoneELECTRICAL Item No 1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr120.32120.3230.0FalseNoneNoneFalseNoneFalse3609.60
3436188121804NoneELECTRICAL Item No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr31.631.6180.0FalseNoneNoneFalseNoneFalse5688.00
3436189121804NoneELECTRICAL Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr51.0551.05600.0FalseNoneNoneFalseNoneFalse30630.00
3436190121804NoneELECTRICAL Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr76.5776.57250.0FalseNoneNoneFalseNoneFalse19142.50
3436191121804NoneELECTRICAL Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3436192121804NoneELECTRICAL Item No 5.19.4MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3436193121804NoneELECTRICAL Item No 5.19.11MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TPN DB ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3436194121804NoneELECTRICAL Item No 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach504.39504.3923.0FalseNoneNoneFalseNoneFalse11600.970
3436195121804NoneELECTRICAL Item No 5.18.3Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach985.69985.691.0FalseNoneNoneFalseNoneFalse985.690
3436196121804NoneELECTRICAL Item No 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach898.18898.184.0FalseNoneNoneFalseNoneFalse3592.720
3436197121804NoneELECTRICAL Item No 5.20.1Supplying,fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach5198.275198.271.0FalseNoneNoneFalseNoneFalse5198.270
3436198121804NoneELECTRICAL Item No 32.07LT UG CABLES 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workKm169607.85169607.850.1FalseNoneNoneFalseNoneFalse16960.7850
3436199121804NoneELECTRICAL Item No BSR-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workKm19639.6519639.650.1FalseNoneNoneFalseNoneFalse1963.9650
3436200121804NoneELECTRICAL Item No SR 19-20 6.11.2Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25mm dia ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach102.09102.098.0FalseNoneNoneFalseNoneFalse816.720
3436201121804NoneELECTRICAL Item No 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNo5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3436202121804NoneELECTRICAL Item No SR 19-20-6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr91.1691.1615.0FalseNoneNoneFalseNoneFalse1367.40
3436203121804NoneELECTRICAL Item No 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V at 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach838.63838.6320.0FalseNoneNoneFalseNoneFalse16772.60
3436204121804NoneELECTRICAL Item No 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V at 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach1075.631075.638.0FalseNoneNoneFalseNoneFalse8605.040
3436205121804NoneELECTRICAL Item No 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach181.09181.094.0FalseNoneNoneFalseNoneFalse724.360
3436206121804NoneELECTRICAL Item No 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach76.5776.574.0FalseNoneNoneFalseNoneFalse306.280
3436207121804NoneELECTRICAL Item No 40757Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workNo4890.774890.771.0FalseNoneNoneFalseNoneFalse4890.770
3436208121804NoneELECTRICAL Item No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach1813.381813.384.0FalseNoneNoneFalseNoneFalse7253.520
3436209121804NoneELECTRICAL Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach3626.753626.7510.0FalseNoneNoneFalseNoneFalse36267.50
3436210121804NoneELECTRICAL Item No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach148.28148.2828.0FalseNoneNoneFalseNoneFalse4151.840
3436211121804NoneELECTRICAL Item No 13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach382.85382.8510.0FalseNoneNoneFalseNoneFalse3828.50
3436212121804NoneELECTRICAL Item No 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach859.29859.294.0FalseNoneNoneFalseNoneFalse3437.160
3436213121804NoneELECTRICAL Item No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3436214121804NoneELECTRICAL Item No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3436215121804NoneELECTRICAL Item No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workSqm0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3436216121804NoneELECTRICAL Item No 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr2995.962995.962.0FalseNoneNoneFalseNoneFalse5991.920
3436217121804NoneELECTRICAL Item No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr370.7370.78.0FalseNoneNoneFalseNoneFalse2965.60
3436218121804NoneELECTRICAL Item No 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workMtr918.84918.848.0FalseNoneNoneFalseNoneFalse7350.720
3436219121804NoneELECTRICAL Item No 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 63A/100Amps 25kA ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3436220121804NoneELECTRICAL Item No 5.17.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps TPN ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach3699.683699.682.0FalseNoneNoneFalseNoneFalse7399.360
3436221121804NoneELECTRICAL Item No 5.17.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3436222121804NoneELECTRICAL Item No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3436223121804NoneELECTRICAL Item No 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3436224121804NoneELECTRICAL Item No 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the workEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17199189190000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17199189190000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17199189190001NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste reserved category as prescribed in the tender document.None
17199189190000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17199189190000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17199189540000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka Public Procurement Portal (KPPP) portal due to internet connectivity issues and technical glitches at bidders end.None
17199189980000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17199190050000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17199190130000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17199190780000NoneNoneELIGIBILITYMaterials like, steel, cement etc., required for the work shall be procured by the tenderer themselves and should got tested positive by the quality control authority before use on the workNone
17199190850000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17199190910000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (Section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17199190970000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17199191020000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have validity for the period of execution.None
17199191100000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contact Help Desk for more assistance Phone: 91-8046010000/91-8068948777).None
17199191160000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within a week time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as non responsive.None
17199191240000NoneNoneELIGIBILITYAdditional Clause: In the case of the death of a contractor after executing the agreement / commencement of the work, his legal heir, if an eligible registered contractor and willing, can execute and complete the work at the accepted tender rates irrespective of the cost of the work.None
17199191960000NoneNoneELIGIBILITYEligible Tenderers will be qualified only if their available tender capacity is more than the total tender value of Rs.49.62 lakhs. The available tender capacity will be calculated as under. Assessed available tender capacity (AxNx5-B).None
17199192270000NoneNoneELIGIBILITYAchieved in at least ONE financial year a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 49.62 Lakhs.None
17199193220000NoneNoneELIGIBILITYThe Bidder Should have completed any one similar work of value not less than of Rs. 12.40 Lakhs.None
17199197330000NoneNoneELIGIBILITYThe Bidder belonging to the Scheduled Caste shall be Domicile of the State of Karnataka for more than 10 years.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneThe Mandating satisfactorily completion of any one similar work of value not less than Rs. 12.40 Lakhs as a prime contractorPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Class-III & Above Civil ContractorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneGST Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneThe tenderer should have been Achieved in at least One financial years a minimum financial turnover (in all classes of civil engineering construction works only) of value Rs. 49.62 lakhs. In the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate issued by competent authority.TrueTechnical Bid
Reserved Schedule Caste Certificate issued by competent authority.TrueTechnical Bid
Annual Turnover Certificate issued by Chartered Accountant along with balance sheetTrueTechnical Bid
Workdone Certificate issued by the officer not below the rank of Executive EngineerTrueTechnical Bid
Domicile Certificate issued by competent authorityTrueTechnical Bid
GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsChitradurgaHiriyurChitradurgaHIRIYUR (SC)TLH HiriyurNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone