1718949271000 | 1 | None | None | Other Works | PKG NO-02-Pumpset No 02 of 75 H.P capacity in Annekere Pumphouse is in disrepair, purchase and installation of new pumpset and installation of pipeline and valve for water supply department in Hangal Municipality and Construction of community building for development programs of disabled persons Under Nagarothan Phase 4 works in TMC Hangal limits. | 7291563.02 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3322632 | 116377 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm
as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(Page No.05. Iitem no.1.1 of Vol-1-CSR-KPWD 2023-2024) | Cum | 93.73 | 93.73 | 10.08 | False | None | None | False | None | False | 944.7984 | 0 | 3322633 | 116377 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In ordinary/soft rock without blasting upto 1.5 m depth(Page No.08. Iitem no.1.15.1 of Vol-1-CSR-KPWD 2021-2022) | Cum | 373.89 | 373.89 | 17.1079 | False | None | None | False | None | False | 6396.472731 | 0 | 3322634 | 116377 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page No.07. Iitem no.1.9 of Vol-1-CSR-KPWD 2021-2022) | Cum | 273.98 | 273.98 | 17.107 | False | None | None | False | None | False | 4686.97586 | 0 | 3322635 | 116377 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(Page No.05. Iitem no.4.1 of Vol-2-CSR-KPWD 2021-2022) | Sqm | 121.54 | 121.54 | 100.8 | False | None | None | False | None | False | 12251.232 | 0 | 3322636 | 116377 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.1.3 of Vol-1-CSR-KPWD 2023-2024) | Cum | 6168.67 | 6168.67 | 14.126 | False | None | None | False | None | False | 87138.63242 | 0 | 3322637 | 116377 | None | code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(Page No.09. Iitem no.5.4 of Vol-2-CSR-KPWD 2023-2024) | Cum | 6580.67 | 6580.67 | 12.373 | False | None | None | False | None | False | 81422.62991 | 0 | 3322638 | 116377 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @8%-Footing Concrete | Cum | 7048.16 | 7048.16 | 5.184 | False | None | None | False | None | False | 36537.66144 | 0 | 3322639 | 116377 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @5%-Pedastals | Cum | 6852.38 | 6852.38 | 0.819 | False | None | None | False | None | False | 5612.09922 | 0 | 3322640 | 116377 | None | code09 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.3.2 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @50%-Plinth Beam | Cum | 10011.6 | 10011.6 | 3.946 | False | None | None | False | None | False | 39505.7736 | 0 | 3322641 | 116377 | None | code10 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.15. Iitem no.2.2.3 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @70%-Columns Below Plinth | Cum | 11094.33 | 11094.33 | 0.248 | False | None | None | False | None | False | 2751.39384 | 0 | 3322642 | 116377 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @70%-Columns Above Plinth | Cum | 11982.09 | 11982.09 | 1.738 | False | None | None | False | None | False | 20824.87242 | 0 | 3322643 | 116377 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @60%-Ground Floor - Lintel Side and Beam | Cum | 11277.26 | 11277.26 | 6.544 | False | None | None | False | None | False | 73798.38944 | 0 | 3322644 | 116377 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @50%-Ground Floor Slab | Cum | 10572.43 | 10572.43 | 13.2 | False | None | None | False | None | False | 139556.076 | 0 | 3322645 | 116377 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Page No.16. Iitem no.2.5.2 of Vol-1-CSR-KPWD 2023-2024)For Centering & Shuttering @45%-Groun Floor -Chejja | Cum | 10220.02 | 10220.02 | 0.5399 | False | None | None | False | None | False | 5517.788798 | 0 | 3322646 | 116377 | None | code15 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification. (The laps and wastages shall not be measured separately)(Page No.99. Iitem no.2.11 of Vol-1-CSR-KPWD 2023-2024) | t | 92140.71 | 92140.71 | 3.1239 | False | None | None | False | None | False | 287838.363969 | 0 | 3322647 | 116377 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications(Page No.17. Iitem no.6.32 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 1349.3 | 1349.3 | 94.43 | False | None | None | False | None | False | 127414.399 | 0 | 3322648 | 116377 | None | code17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No.17. Iitem no.6.33 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 1267.93 | 1267.93 | 23.52 | False | None | None | False | None | False | 29821.7136 | 0 | 3322649 | 116377 | None | code18 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off orners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing complete as per pecifications and as per directions of Engineer-in-charge(In side Plastering)(Page No.41. Iitem no.8.4.1 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 332.69 | 332.69 | 187.159 | False | None | None | False | None | False | 62265.92771 | 0 | 3322650 | 116377 | None | code19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Page No.41. Iitem no.8.2.1 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 303.85 | 303.85 | 132.68 | False | None | None | False | None | False | 40314.818 | 0 | 3322651 | 116377 | None | code20 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Page No.63. Iitem no.9.24 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 2937.56 | 2937.56 | 92.72 | False | None | None | False | None | False | 272370.5632 | 0 | 3322652 | 116377 | None | code21 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile Colour glazed tile 30x45 cms 6mm thick with border of size 30 x 10 cms(Page No.60. Iitem no.9.7.2 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 1297.8 | 1297.8 | 54.8 | False | None | None | False | None | False | 71119.44 | 0 | 3322653 | 116377 | None | code22 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(Page No.64. Iitem no.9.30 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 5487.84 | 5487.84 | 1.799 | False | None | None | False | None | False | 9872.62416 | 0 | 3322654 | 116377 | None | code23 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.45. Iitem no.8.29 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 291.49 | 291.49 | 132.68 | False | None | None | False | None | False | 38674.8932 | 0 | 3322655 | 116377 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50. Iitem no.8.51 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 103.0 | 103.0 | 187.159 | False | None | None | False | None | False | 19277.377 | 0 | 3322656 | 116377 | None | code25 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.48. Iitem no.8.39 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 130.81 | 130.81 | 187.159 | False | None | None | False | None | False | 24482.26879 | 0 | 3322657 | 116377 | None | code26 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(Page No.99. Iitem no.12.12 of Vol-2-CSR-KPWD 2023-2024) | Cum | 127928.06 | 127928.06 | 0.077 | False | None | None | False | None | False | 9850.46062 | 0 | 3322658 | 116377 | None | code27 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak(Page No.105. Iitem no.12.57.1 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 4164.29 | 4164.29 | 4.2 | False | None | None | False | None | False | 17490.018 | 0 | 3322659 | 116377 | None | code28 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x70x4 mm (ordinary type)(Page No.107. Iitem no.12.75.4 of Vol-2-CSR-KPWD 2023-2024) | No | 144.2 | 144.2 | 3.0 | False | None | None | False | None | False | 432.6 | 0 | 3322660 | 116377 | None | code29 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm(Page No.107. Iitem no.12.76.2 of Vol-2-CSR-KPWD 2023-2024) | Each | 360.5 | 360.5 | 3.0 | False | None | None | False | None | False | 1081.5 | 0 | 3322661 | 116377 | None | code30 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10mm(Page No.107. Iitem no.12.76.4 of Vol-2-CSR-KPWD 2023-2024) | Each | 202.91 | 202.91 | 3.0 | False | None | None | False | None | False | 608.73 | 0 | 3322662 | 116377 | None | code31 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.(Page No.105. Iitem no.12.61 of Vol-2-CSR-KPWD 2023-2024) | Each | 1019.7 | 1019.7 | 1.0 | False | None | None | False | None | False | 1019.7 | 0 | 3322663 | 116377 | None | code32 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(Page No.105. Iitem no.12.60 of Vol-2-CSR-KPWD 2023-2024) | No | 1083.56 | 1083.56 | 1.0 | False | None | None | False | None | False | 1083.56 | 0 | 3322664 | 116377 | None | code33 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete(Page No.105. Iitem no.12.62 of Vol-2-CSR-KPWD 2023-2024) | No | 244.11 | 244.11 | 1.0 | False | None | None | False | None | False | 244.11 | 0 | 3322665 | 116377 | None | code34 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(Page No.105. Iitem no.12.59 of Vol-2-CSR-KPWD 2023-2024) | No | 1147.42 | 1147.42 | 1.0 | False | None | None | False | None | False | 1147.42 | 0 | 3322666 | 116377 | None | code35 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.(Page No.105. Iitem no.12.58 of Vol-2-CSR-KPWD 2023-2024) | No | 123.6 | 123.6 | 1.0 | False | None | None | False | None | False | 123.6 | 0 | 3322667 | 116377 | None | code36 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Page No.104. Iitem no.12.51 of Vol-2-CSR-KPWD 2023-2024) | No | 1046.48 | 1046.48 | 1.0 | False | None | None | False | None | False | 1046.48 | 0 | 3322668 | 116377 | None | code37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.(Page No.86. Iitem no.11.34B of Vol-2-CSR-KPWD 2023-2024) | Kg | 188.49 | 188.49 | 243.0 | False | None | None | False | None | False | 45803.07 | 0 | 3322669 | 116377 | None | code38 | Providing fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Page No.110. Iitem no.12.90 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 6936.02 | 6936.02 | 13.5 | False | None | None | False | None | False | 93636.27 | 0 | 3322670 | 116377 | None | code39 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.47. Iitem no.8.34.2 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 59.74 | 59.74 | 4.2 | False | None | None | False | None | False | 250.908 | 0 | 3322671 | 116377 | None | code40 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.46. Iitem no.8.33.2 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 142.14 | 142.14 | 4.2 | False | None | None | False | None | False | 596.988 | 0 | 3322672 | 116377 | None | code41 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page No.48. Iitem no.8.37 of Vol-2-CSR-KPWD 2023-2024) | Sqm | 134.93 | 134.93 | 13.5 | False | None | None | False | None | False | 1821.555 | 0 | 3322673 | 116377 | None | code42 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as(Page No.85. Iitem no.11.28 of Vol-2-CSR-KPWD 2023-2024) | Kg | 581.95 | 581.95 | 10.0 | False | None | None | False | None | False | 5819.5 | 0 | 3322674 | 116377 | None | code43 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Workcompletion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804(Page No.78. Iitem no.8.54 of Vol-3-CSR-KPWD 2023-2024) | No | 9270.0 | 9270.0 | 1.0 | False | None | None | False | None | False | 9270.0 | 0 | 3322675 | 116377 | None | code44 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 5.5 m3)a (Page No.3. Iitem no.1.1 of Vol-3-CSR-KPWD 2023-2024) | Cum | 139.05 | 139.05 | 27.187 | False | None | None | False | None | False | 3780.35235 | 0 | 3322676 | 116377 | None | code45 | ConcealedConduiteSystem:SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCenenclosures,runwith18SWGGIfishwirewherever necessary.25mm dia 2mm thick (CSR-KPWD - Electrical SR, 2023-24: Page No.2, Item No. 1.2.2). | Mtr | 78.0 | 78.0 | 40.0 | False | None | None | False | None | False | 3120.0 | 0 | 3322677 | 116377 | None | code46 | ConcealedConduiteSystem:SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCenenclosures,runwith18SWGGIfishwirewherever necessary.32mm dia 2.5mm thick (CSR-KPWD - Electrical SR, 2023-24: Page No.2, Item No. 1.2.3). | Mtr | 103.0 | 103.0 | 40.0 | False | None | None | False | None | False | 4120.0 | 0 | 3322678 | 116377 | None | code47 | supplying and fixing PVC /metal conduit deep junction box. 32mm deep junction box(CSR-KPWD - Electrical SR, 2023-24 Page No.3, Item No. 1.5.3). | Each | 61.0 | 61.0 | 5.0 | False | None | None | False | None | False | 305.0 | 0 | 3322679 | 116377 | None | code48 | Extra for groove cutting in brick wall/CC wall/CC floor to the suitable depth of conduit/GI pipe and plastering, finishing upto wall surface complete Upto 50mm conduit in brick wall (CSR-KPWD - Electrical SR, 2023-24: Page No.3, Item No. 1.7.1). | m | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | 3322680 | 116377 | None | code49 | Supplying & fixing metal fan box with round hook (CSR-KPWD - Electrical SR, 2023-24: Page No.4, Item No. 1.13). | No | 117.0 | 117.0 | 1.0 | False | None | None | False | None | False | 117.0 | 0 | 3322681 | 116377 | None | code50 | Supplying and flush mounting power coated metal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting in bricks/ stone/c.c wall.6Way (CSR-KPWD - Electrical SR, 2023-24: Page No.8, Item No.3.4.4). | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 | 3322682 | 116377 | None | code51 | Supplying and flush mounting power coated metal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting in bricks/ stone/c.c wall.8Way (CSR-KPWD - Electrical SR, 2023-24: Page No.8, Item No.3.4.5). | Each | 261.0 | 261.0 | 3.0 | False | None | None | False | None | False | 783.0 | 0 | 3322683 | 116377 | None | code52 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V grade, multtis and copper conductor single core cable in consealed system of wining.(group A materials). With specified IS-694:1990, 1.5 Sqmm (CSR-KPWD - Electrical SR, 2023-24: Page No.5. Item No.2.3.2). | Mtr | 26.0 | 26.0 | 80.0 | False | None | None | False | None | False | 2080.0 | 0 | 3322684 | 116377 | None | code53 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V grade, multtis and copper conductor single core cable in consealed system of wiring.(group A materials). With specified IS-694:1990, 2.5 Sqmm (CSR-KPWD - Electrical SR, 2023-24: Page No.5, Item No.2.3.3). | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | 3322685 | 116377 | None | code54 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V grade, multtis and copper conductor single core cable in consealed system of wiring.(group A materials). With specified IS-694:1990, 6.0 Sqmm (CSR-KPWD - Electrical SR, 2023-24: Page No.5, Item No.2.3.5). | Mtr | 92.0 | 92.0 | 40.0 | False | None | None | False | None | False | 3680.0 | 0 | 3322686 | 116377 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module (CSR-KPWD - Electrical SR, 2023-24: Page No.8, Item No.3.5.4). | Each | 234.0 | 234.0 | 4.0 | False | None | None | False | None | False | 936.0 | 0 | 3322687 | 116377 | None | code56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos, of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module (CSR-KPWD - Electrical SR, 2023-24 Page No.8, Item No.3.5.5). | Each | 284.0 | 284.0 | 3.0 | False | None | None | False | None | False | 852.0 | 0 | 3322688 | 116377 | None | code57 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-6 Amps One way Switch (CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.1). | Each | 102.0 | 102.0 | 3.0 | False | None | None | False | None | False | 306.0 | 0 | 3322689 | 116377 | None | code58 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-Stepped Fan Regulator Two Module (CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.4). | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 | 3322690 | 116377 | None | code59 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-16A One Way Switch(CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.7). | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 | 3322691 | 116377 | None | code60 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-32A DP Switch(CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.9). | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 3322692 | 116377 | None | code61 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-6/16A Universal Socket-(CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.10). | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3322693 | 116377 | None | code62 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.-RJ45/I.O Outlet Cat-6-(CSR-KPWD - Electrical SR, 2023-24: Page No.9, Item No.3.6.12). | Each | 337.0 | 337.0 | 1.0 | False | None | None | False | None | False | 337.0 | 0 | 3322694 | 116377 | None | code63 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz
68 & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturingdefect working under standard electrical condition LED light fighting 1 x 2 - 9/10w (CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No.11.3.1). | Each | 551.0 | 551.0 | 2.0 | False | None | None | False | None | False | 1102.0 | 0 | 3322695 | 116377 | None | code64 | Supplying of .......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturingdefect working under standard electrical condition LED light fighting 1 x 4' - 20/22w (CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No.11.3.2). | Each | 690.0 | 690.0 | 2.0 | False | None | None | False | None | False | 1380.0 | 0 | 3322696 | 116377 | None | code65 | SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/10%RPM,Ratedairdelivery210+/10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans)-48" Sweep 5 Star (1200 mm) (CSR-KPWD - Electrical SR, 2023-24: Page No.30, Item No.6.4.1). | Each | 2677.0 | 2677.0 | 2.0 | False | None | None | False | None | False | 5354.0 | 0 | 3322697 | 116377 | None | code66 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(CSR-KPWD - Electrical SR, 2023-24 Page No.57, Item No.13.10). | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 | 3322698 | 116377 | None | code67 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP (CSR-KPWD - Electrical SR, 2023-24: Page No.17, Item No.5.18.1). | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 3322699 | 116377 | None | code68 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps TPN (CSR-KPWD - Electrical SR, 2023-24: Page No.17, Item No.5.18.7). | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 | 3322700 | 116377 | None | code69 | Supplying, fixing and wiring earth leakage miniature circuit Breaker (ELMCB) 240/450V up to 75 300mA sensitivity on existing wood/panel board. 32-40 Amps 4 pole (CSR-KPWD - Electrical SR, 2023-24 Page No.18, Item No.5.20.8). | Each | 5147.0 | 5147.0 | 1.0 | False | None | None | False | None | False | 5147.0 | 0 | 3322701 | 116377 | None | code70 | SupplyingandfixingregularMCBdistributionboardsonwall/oodboard/flushmountingusingrequiredclamps,bolts,nutsetc.,withprovisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/singledoorwithpowdercoatedpaintingMadeoutof14SWGMS enclosure.. 12 Way SP&N (Double door) (CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No.5.19.9). | Each | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 | 3322702 | 116377 | None | code71 | Fabricating supplying and mounting MS box made out 14 SWG suitable for Floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged fronth cover, equipped with tamper proof locking arrangemnets, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc. complete 14SWg (CSR-KPWD - Electrical SR, 2023-24: Page No.20, Item No.5.42.1). | Sq CM | 0.5 | 0.5 | 6000.0 | False | None | None | False | None | False | 3000.0 | 0 | 3322703 | 116377 | None | code72 | Supplying and fixing moulded case circuit breaker over the existing wood/ panel board using neccesary screws bolts nuts and wiring complete. Protection of overload and short circuit with thermal magnetic release and earth fault as per IS 13947 (Icu=lcs) (WITH ALL LEAD AND LIFT AS PER DIRECTION OF ENGINEER IN CHARGE OF WORK.) -4 pole - 320-400Amps 50kA.(CSR-KPWD - Electrical SR, 2022-23: Page No.27, Item No.5.14.12). | Each | 29092.0 | 29092.0 | 1.0 | False | None | None | False | None | False | 29092.0 | 0 | 3322704 | 116377 | None | code73 | Supplying...... Amps rated 3 phase with neutral bus bar using rtequired capacity electronic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S. flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cabels as per IS specification with necessary bolts, nuts, and washers etc, complete.400 Amps 4x50x10mm Aluminium Strips (CSR-KPWD - Electrical SR, 2023-24:: Page No.20, Item No.5.40.3). | Mtr | 4445.0 | 4445.0 | 1.0 | False | None | None | False | None | False | 4445.0 | 0 | 3322705 | 116377 | None | code74 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975,35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) (CSR -BESCOM, 2022-23- Page No.13 SL NO-205-, Item No.32.09).Material-Code-287059 | Km | 154062.0 | 154062.0 | 0.015 | False | None | None | False | None | False | 2310.93 | 0 | 3322706 | 116377 | None | code75 | Supplying and fixing of solar Lux level street light control
switch three phase including suitable capacity contactor-12 kW (CSR -BESCOM, 2022-23- Page No.21 -, Item No.5.50.3).Material-Code-287059 | Each | 16635.0 | 16635.0 | 1.0 | False | None | None | False | None | False | 16635.0 | 0 | 3322707 | 116377 | None | code76 | Providing supplying and installation at work Set of suitable for verticle fitting and confirming to IS 3Phase, an For 75 HP as per ISI specification with all work site, verticle turbine Pump Inecessary materials like cebal NIV, earthing, suitable panel board ete eminent and equipments with guarantee period of not less necessary ammendments and instructions of incharge of work per specifications, as per 4 months (data rate) | Set | 2100000.0 | 2100000.0 | 1.0 | False | None | None | False | None | False | 2100000.0 | 0 | 3322708 | 116377 | None | code77 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger
lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth
in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair
manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner).(Page No.48. Iitem no.3.3 of Vol-5-CSR-KPWD 2023-2024) | Cum | 1191.71 | 1191.71 | 209.925 | False | None | None | False | None | False | 250169.72175 | 0 | 3322709 | 116377 | None | code78 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. (Page No.10. Iitem no.1.17.1 of Vol-1-CSR-KPWD 2023-2024)All kinds of soils. Depth upto 1.50 m | Cum | 269.86 | 269.86 | 1213.2 | False | None | None | False | None | False | 327394.152 | 0 | 3322710 | 116377 | None | code79 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For-PVC pipes 200mm dia., 6 kg/sqcm &class 3(Page No.113. Iitem no.10.1.10 of Vol-5-CSR-KPWD 2023-2024) | m | 1148.45 | 1148.45 | 1550.0 | False | None | None | False | None | False | 1780097.5 | 0 | 3322711 | 116377 | None | code80 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For-PVC pipes 160mm dia., 6 kg/sqcm &class 3(Page No.113. Iitem no.10.1.9 of Vol-5-CSR-KPWD 2023-2024) | m | 636.54 | 636.54 | 570.0 | False | None | None | False | None | False | 362827.8 | 0 | 3322712 | 116377 | None | code81 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For-PVC pipes 90mm dia., 6 kg/sqcm &class 3(Page No.113. Iitem no.10.1.6 of Vol-5-CSR-KPWD 2023-2024) | m | 302.82 | 302.82 | 100.0 | False | None | None | False | None | False | 30282.0 | 0 | 3322713 | 116377 | None | code82 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(Page No.96. Iitem no.9.1.9 of Vol-5-CSR-KPWD 2023-2024)HDPE Grade PE80-PN6.0 200 | m | 1482.17 | 1482.17 | 90.0 | False | None | None | False | None | False | 133395.3 | 0 | 3322714 | 116377 | None | code83 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost ofcorresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23.2 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN -10.0 and 80mm | Each | 10704.79 | 10704.79 | 5.0 | False | None | None | False | None | False | 53523.95 | 0 | 3322715 | 116377 | None | code84 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost ofcorresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23.4 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN -10.0 and 150mm | Each | 18014.7 | 18014.7 | 8.0 | False | None | None | False | None | False | 144117.6 | 0 | 3322716 | 116377 | None | code85 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost ofcorresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23.5 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN -10.0 and 200mm | Each | 29570.27 | 29570.27 | 6.0 | False | None | None | False | None | False | 177421.62 | 0 | 3322717 | 116377 | None | code86 | Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.(Page No.71. Iitem no.8.29 of Vol-03-CSR-KPWD 2023-2024)(i) Single row for one utility service | m | 2278.36 | 2278.36 | 54.0 | False | None | None | False | None | False | 123031.44 | 0 | 3322718 | 116377 | None | code87 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Workcompletion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804(Page No.78. Iitem no.8.54 of Vol-3-CSR-KPWD 2023-2024) | No | 9270.0 | 9270.0 | 2.0 | False | None | None | False | None | False | 18540.0 | 0 |
|