createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719488817773
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd480000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 17:30:00
tenderQueryClose02-08-2024 17:30:00
technicalBidOpen07-08-2024 11:00:00
publishedDate02-07-2024 19:30:11
publishedByPostCMC_MCOM_BDVT
publishedByUserKPE14519 - P M CHANNAPPANAVAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate12-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPrasad K JE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9986922162
tenderSupplierListNone
tenderSchedule
createdTs1719488817801
version13
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT18885
titleConstructionn of Proposed 34 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Hiriyuru land fill site in Bhadravthi CMC
descriptionConstructionn of Proposed 34 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Hiriyuru land fill site in Bhadravthi CMC
categoryWORKS
categoryTextWorks
ecv32000000.03
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2392
locationNameDMA City Municipal Council Bhadravathi
provisionalAmount32000000.0
groupOverheadTotal5977823.07
fileNumberMRF/Tender/2024-25/SBM-2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17194888180001NoneNoneBuildingsConstructionn of Proposed 35TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Hiriyuru land fill site in Bhadravthi CMC26022176.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3386477119265NoneCode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.06285.89FalseNoneNoneFalseNoneFalse30035.60340
3386478119265NoneCode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.92250.33FalseNoneNoneFalseNoneFalse1460405.19360
3386479119265NoneCode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for foottingCum7208.357208.3569.84FalseNoneNoneFalseNoneFalse503431.1640
3386480119265NoneCode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for column pedestal and side wallCum11346.4811346.4832.78FalseNoneNoneFalseNoneFalse371937.61440
3386481119265NoneCode05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for hall grade slab and rampCum7208.357208.35310.99FalseNoneNoneFalseNoneFalse2241724.76650
3386482119265NoneCode06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9789.129789.1223.37FalseNoneNoneFalseNoneFalse228771.73440
3386483119265NoneCode07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne92140.7192140.7125.8281FalseNoneNoneFalseNoneFalse2379819.4719510
3386484119265NoneCode08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.67105.5FalseNoneNoneFalseNoneFalse694260.6850
3386485119265NoneCode09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.222508.38FalseNoneNoneFalseNoneFalse1224641.28360
3386486119265NoneCode10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93489.24FalseNoneNoneFalseNoneFalse620322.07320
3386487119265NoneCode11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm303.85303.851016.9FalseNoneNoneFalseNoneFalse308985.0650
3386488119265NoneCode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.3992800.0FalseNoneNoneFalseNoneFalse10800992.00
3386489119265NoneCode13Turbo fans Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 0.9mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 5.2kg for Industrial use. (KPWD common SR2023-24 Vol 2, I.No 7.69.1 P.no 38)No5376.65376.614.0FalseNoneNoneFalseNoneFalse75272.40
3386490119265NoneCode14Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.043797.28FalseNoneNoneFalseNoneFalse2221560.69120
3386491119265NoneCode15KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm103.0103.01016.9FalseNoneNoneFalseNoneFalse104740.70
3386492119265NoneCode16KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm75.1975.19497.06FalseNoneNoneFalseNoneFalse37373.94140
3386493119265NoneCode17KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm75.1975.19456.35FalseNoneNoneFalseNoneFalse34312.95650
3386494119265NoneCode18KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9957.38FalseNoneNoneFalseNoneFalse155613.98620
3386495119265NoneCode19KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25426.5825426.583.0FalseNoneNoneFalseNoneFalse76279.740
3386496119265NoneCode20KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.561020.0FalseNoneNoneFalseNoneFalse474871.20
3386497119265NoneCode21Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG .(KPWD common SR 2023-24 Item No. 5.42.2, Page No. 20, Vol.6) mani and sub panelcm0.430.4321600.0FalseNoneNoneFalseNoneFalse9288.00
3386498119265NoneCode22Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm.(KPWD common SR 2023-24 Item No. 5.41.2, Page No. 20, Vol.6)Mtr395.0395.027.0FalseNoneNoneFalseNoneFalse10665.00
3386499119265NoneCode23Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips (KPWD common SR 2023-24 Item No. 5.40.2, Page No. 20, Vol.6)Mtr3435.03435.012.0FalseNoneNoneFalseNoneFalse41220.00
3386500119265NoneCode24Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (KPWD common SR 2023-24 Item No. 5.15.16. Page No. 16,17, Vol.6) 400 A 36 kA MCCB FOUR PoleEach28216.028216.01.0FalseNoneNoneFalseNoneFalse28216.00
3386501119265NoneCode25Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (KPWD common SR 2023-24 Item No. 5.15.9. Page No. 16,17, Vol.6) 100 A 25 kA FOUR PoleEach8487.08487.02.0FalseNoneNoneFalseNoneFalse16974.00
3386502119265NoneCode26Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. (KPWD common SR 2023-24 Item No. 5.17.1. Page No. 17, Vol.6) 4 WayEach10329.010329.02.0FalseNoneNoneFalseNoneFalse20658.00
3386503119265NoneCode27Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (KPWD common SR 2023-24 Item No. 5.18.3. Page No. 17, Vol.6) 50-63 A SPEach811.0811.011.0FalseNoneNoneFalseNoneFalse8921.00
3386504119265NoneCode28Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (KPWD common SR 2023-24 Item No. 5.19.5. Page No. 18, Vol.6) I - Single Door 16 Way SP & NEach2932.02932.04.0FalseNoneNoneFalseNoneFalse11728.00
3386505119265NoneCode29Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. (KPWD common SR 2023-24 Item No. 5.20.10. Page No. 18, Vol.6) 63 A 4 poleEach5545.05545.010.0FalseNoneNoneFalseNoneFalse55450.00
3386506119265NoneCode30Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. . (KPWD common SR 2023-24 Item No. 5.21. Page No. 18, Vol.6)Each9255.09255.02.0FalseNoneNoneFalseNoneFalse18510.00
3386507119265NoneCode31Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. (KPWD common SR 2023-24 Item No. 5.22. Page No. 18, Vol.6)Each452.0452.02.0FalseNoneNoneFalseNoneFalse904.00
3386508119265NoneCode32Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter (KPWD common SR 2023-24 Item No. 5.24. Page No. 18, Vol.6)Each465.0465.02.0FalseNoneNoneFalseNoneFalse930.00
3386509119265NoneCode33Supplying, fixing and wiring rotary selector switch suitable for Ammeter (KPWD common SR 2023-24 Item No. 5.27. Page No. 19, Vol.6)Each200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
3386510119265NoneCode34Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter (KPWD common SR 2023-24 Item No. 5.29. Page No. 19, Vol.6)Each1425.01425.02.0FalseNoneNoneFalseNoneFalse2850.00
3386511119265NoneCode35Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. (KPWD common SR 2023-24 Item No. 5.31. Page No. 19, Vol.6)Each4390.04390.01.0FalseNoneNoneFalseNoneFalse4390.00
3386512119265NoneCode36Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (KPWD common SR 2023-24 Item No. 5.33. Page No. 19, Vol.6)Each9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3386513119265NoneCode37Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage,50HZ frequency and as per IS 60947-4-1. (KPWD common SR 2023-24 Item No. 5.52.1 Page No. 22, Vol.6) 12.5 KVAREach2901.02901.02.0FalseNoneNoneFalseNoneFalse5802.00
3386514119265NoneCode38Supplying and fixing HRC fuse units base on existing switch / panel board. (KPWD common SR 2023-24 Item No. 5.9.4 Page No. 15, Vol.6) 315 to 630 AEach1212.01212.06.0FalseNoneNoneFalseNoneFalse7272.00
3386515119265NoneCode39Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703. (KPWD common SR 2023-24 Item No. 5.10.5 Page No. 15, Vol.6) Above 425 A to 630 AEach1148.01148.06.0FalseNoneNoneFalseNoneFalse6888.00
3386516119265NoneCode40Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. (KPWD common SR 2023-24 Item No. 5.14.6 Page No. 16, Vol.6) 95/100 AEach16606.016606.02.0FalseNoneNoneFalseNoneFalse33212.00
3386517119265NoneCode411.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.16 Page No. 13, Vol.6)Km554655.0554655.00.15FalseNoneNoneFalseNoneFalse83198.250
3386518119265NoneCode421.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.13 Page No. 13, Vol.6)Km317912.0317912.00.12FalseNoneNoneFalseNoneFalse38149.440
3386519119265NoneCode431.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.12 Page No. 13, Vol.6)Km207194.0207194.00.12FalseNoneNoneFalseNoneFalse24863.280
3386520119265NoneCode441.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.08 Page No. 13, Vol.6)Km179844.0179844.00.1FalseNoneNoneFalseNoneFalse17984.40
3386521119265NoneCode451.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.05 Page No. 13, Vol.6)Km141842.0141842.00.15FalseNoneNoneFalseNoneFalse21276.30
3386522119265NoneCode46Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.3.6 Page No. 6, Vol.6) 4CX10 mm2Mtr167.0167.0180.0FalseNoneNoneFalseNoneFalse30060.00
3386523119265NoneCode47Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.3.5 Page No. 6, Vol.6) 4CX 6 mm2Mtr92.092.0160.0FalseNoneNoneFalseNoneFalse14720.00
3386524119265NoneCode48Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.5.22 Page No. 7, Vol.6) 3CX6 mm2Mtr253.0253.0300.0FalseNoneNoneFalseNoneFalse75900.00
3386525119265NoneCode49Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.5.15 Page No. 6, Vol.6) 3CX4 mm2Mtr172.0172.0250.0FalseNoneNoneFalseNoneFalse43000.00
3386526119265NoneCode50Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.11 Page No. 14, Vol.6) 185 Sqmm, 3.5/4 CoreSet1717.01717.08.0FalseNoneNoneFalseNoneFalse13736.00
3386527119265NoneCode51Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.08 Page No. 14, Vol.6) 70 Sqmm, 3.5/4 CoreSet1055.01055.08.0FalseNoneNoneFalseNoneFalse8440.00
3386528119265NoneCode52Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.07 Page No. 14, Vol.6) 50 Sqmm, 4 CoreSet855.0855.08.0FalseNoneNoneFalseNoneFalse6840.00
3386529119265NoneCode53Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.06 Page No. 14, Vol.6) 25 Sqmm, 4 CoreSet750.0750.010.0FalseNoneNoneFalseNoneFalse7500.00
3386530119265NoneCode54Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.04 Page No. 14, Vol.6) 16 Sqmm, 4 CoreSet698.0698.012.0FalseNoneNoneFalseNoneFalse8376.00
3386531119265NoneCode55Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.02 Page No. 14, Vol.6) 10 Sqmm, 4 CoreSet698.0698.014.0FalseNoneNoneFalseNoneFalse9772.00
3386532119265NoneCode56Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34. 14 Page No. 15, Vol.6) 6 Sqmm, 4 CoreSet630.0630.014.0FalseNoneNoneFalseNoneFalse8820.00
3386533119265NoneCode57Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.14 Page No. 15, Vol.6) up to 6 SqmmSet630.0630.016.0FalseNoneNoneFalseNoneFalse10080.00
3386534119265NoneCode58Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.14 Page No. 15, Vol.6) up to 6 SqmmSet630.0630.012.0FalseNoneNoneFalseNoneFalse7560.00
3386535119265NoneCode59Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm (KPWD common SR 2023-24 hescom part II Item No. 59.04 Page No. 26, Vol.6)No89.089.024.0FalseNoneNoneFalseNoneFalse2136.00
3386536119265NoneCode60Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 59.01 Page No. 26, Vol.6)No27.027.024.0FalseNoneNoneFalseNoneFalse648.00
3386537119265NoneCode61Heavy Duty Copper Terminal Long Barrel 16 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.02 Page No. 27, Vol.6)No2.02.024.0FalseNoneNoneFalseNoneFalse48.00
3386538119265NoneCode62Heavy Duty Copper Terminal Long Barrel 10 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6)No2.02.024.0FalseNoneNoneFalseNoneFalse48.00
3386539119265NoneCode63Heavy Duty Copper Terminal Long Barrel 6 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6)No2.02.024.0FalseNoneNoneFalseNoneFalse48.00
3386540119265NoneCode64Heavy Duty Copper Terminal Long Barrel 4 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6)No2.02.024.0FalseNoneNoneFalseNoneFalse48.00
3386541119265NoneCode65Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.05 Page No. 59, Vol.6)Km20886.020886.00.15FalseNoneNoneFalseNoneFalse3132.90
3386542119265NoneCode66Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.06 Page No. 59, Vol.6)Km31139.031139.00.34FalseNoneNoneFalseNoneFalse10587.260
3386543119265NoneCode67Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.07 Page No. 59, Vol.6)Km32278.032278.00.15FalseNoneNoneFalseNoneFalse4841.70
3386544119265NoneCode68Heat shrinkable Straight Through Joint 2.5 to 25 Sqmm (KPWD common SR 2023-24 escom part II Item No. 22.09 Page No. 59, Vol.6)Set143.0143.08.0FalseNoneNoneFalseNoneFalse1144.00
3386545119265NoneCode69Heat shrinkable Straight Through Joint 35 to 95 Sqmm(KPWD common SR 2023-24 escom part II Item No. 22.10 Page No. 59, Vol.6)Set284.0284.024.0FalseNoneNoneFalseNoneFalse6816.00
3386546119265NoneCode70Heat shrinkable Straight Through Joint 120 to 240 Sqmm (KPWD common SR 2023-24 escom part II Item No. 22.10 Page No. 59, Vol.6)Set380.0380.08.0FalseNoneNoneFalseNoneFalse3040.00
3386547119265NoneCode71RCC Hume Pipe 2000 mm long 200 mm Dia (KPWD common SR 2023-24 escom part II Item No. 68.02 Page No. 30, Vol.6)No390.0390.065.0FalseNoneNoneFalseNoneFalse25350.00
3386548119265NoneCode72Collars for RCC Hume Pipe 200 mm Dia (KPWD common SR 2023-24 escom part II Item No. 68.02 Page No. 30, Vol.6)No103.0103.065.0FalseNoneNoneFalseNoneFalse6695.00
3386549119265NoneCode73Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. (KPWD common SR 2023-24 Item No.5.14.6 Page No. 16, Vol.6)No16606.016606.02.0FalseNoneNoneFalseNoneFalse33212.00
3386550119265NoneCode74Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (KPWD common SR 2023-24 Item No.29.03 Page No. 63, Vol.6) UG cable work In Hard SoilCum389.0389.0460.7999FalseNoneNoneFalseNoneFalse179251.16110
3386551119265NoneCode75Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (KPWD common SR 2023-24 Item No.29.07 Page No. 63, Vol.6) UG cable workCum58.058.0288.0FalseNoneNoneFalseNoneFalse16704.00
3386552119265NoneCode76Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure. (KPWD common SR 2023-24 KPTCL section Item No.3 Page No.158, Vol.6) UG cable workCum1965.01965.096.0FalseNoneNoneFalseNoneFalse188640.00
3386553119265NoneCode77PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduitMtr69.069.01000.0FalseNoneNoneFalseNoneFalse69000.00
3386554119265NoneCode78PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2 , 25mm dia PVC 2mm thick conduitMtr81.081.01000.0FalseNoneNoneFalseNoneFalse81000.00
3386555119265NoneCode79PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2 , 32mm dia PVC 2mm thick conduitMtr106.0106.0600.0FalseNoneNoneFalseNoneFalse63600.00
3386556119265NoneCode80PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2 , 40mm dia PVC 2mm thick conduitMtr149.0149.0800.0FalseNoneNoneFalseNoneFalse119200.00
3386557119265NoneCode81Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-2, PAGE NO-5Point285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3386558119265NoneCode82Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 3M upto 6Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-2, PAGE NO-5Point394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
3386559119265NoneCode83Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 6M upto 10Mtr from switch board , CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-2, PAGE NO-5Point570.0570.017.0FalseNoneNoneFalseNoneFalse9690.00
3386560119265NoneCode84Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-5Point708.0708.02.0FalseNoneNoneFalseNoneFalse1416.00
3386561119265NoneCode85Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-5Point1035.01035.08.0FalseNoneNoneFalseNoneFalse8280.00
3386562119265NoneCode86Circuit main wiring Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-2, PAGE NO-5Mtr19.019.0800.0FalseNoneNoneFalseNoneFalse15200.00
3386563119265NoneCode87Circuit main wiring Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 1.50 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-2, PAGE NO-5Mtr26.026.0800.0FalseNoneNoneFalseNoneFalse20800.00
3386564119265NoneCode88Circuit main wiring Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 2.50 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-2, PAGE NO-5Mtr42.042.0800.0FalseNoneNoneFalseNoneFalse33600.00
3386565119265NoneCode89Circuit main wiring Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010,. 4.00 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-2, PAGE NO-5Mtr63.063.0600.0FalseNoneNoneFalseNoneFalse37800.00
3386566119265NoneCode90Circuit main wiring Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 6.00 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-2, PAGE NO-5Mtr92.092.0400.0FalseNoneNoneFalseNoneFalse36800.00
3386567119265NoneCode91Supplying and fixing of modular switch & connected accessories on Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9No102.0102.025.0FalseNoneNoneFalseNoneFalse2550.00
3386568119265NoneCode92Supplying and fixing of modular switch & connected accessories on Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9No171.0171.020.0FalseNoneNoneFalseNoneFalse3420.00
3386569119265NoneCode93Supplying and fixing of modular switch & connected accessories on Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9No357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
3386570119265NoneCode94Supplying and fixing of modular switch & connected accessories on Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9No236.0236.020.0FalseNoneNoneFalseNoneFalse4720.00
3386571119265NoneCode95Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater-than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater-than IK08. Power Factor Greater-than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency Greater-than 1301m/w, nominal CRI Greater-than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ,CSR Electrical SR-2023-24, ITEM NO:11.9.2 ,CH-11, PAGE NO-46No9486.09486.020.0FalseNoneNoneFalseNoneFalse189720.00
3386572119265NoneCode96Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) (KPWD common SR 2023-24 KPTCL section Item No.22.a.ii Page No.120, Vol.6) celing cable workMtr754.0754.085.0FalseNoneNoneFalseNoneFalse64090.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17194888190000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17194888190000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17194888190000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17194888190000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17194888190000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17194888400000NoneNoneELIGIBILITYAll term and Conditions as per tender Doucmnet (KW-4)None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneExecuted in any one year (for a continuous period of 12 months) the following minimum quantities of work 1) Earth work excavation and Embankment Refilling-Cum-2235.00, 2) Providing and laying in PCC/RCC-Cum-550.00, 3) Steel Fabrication: Supplying, fitting and placing TMT Steel Reinforcement-tonne-21.00, 4) Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work-kg-74240.00, 5) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)-sqm-3038.00Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneSatisfactory completed, at least one similar work on Building of value not less than Rs. 160.00 Lakhs as prime contractor in the last five years in 2019-20 to 2023-24Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneNot applicable Each tenderer should further demonstrateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Other
NoneNoneNoneNoneAchieved in at least two financial years in last five years in 2019-20 to 2023-24 a minimum financial Annual Turnover Certificate Dually Certified by Charted Accountant (in all classes of civil engineering construction works only) of Rs 640.00 lakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs.96.00 Lakhs (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Liquid assets
NoneNoneNoneNoneCurrent Valid Class-1 PWD Civil License Registration CopyOthersRegistration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneExisting ongoing works Details Submit in Prescribed format in this DocumentOthersOngoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing works
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Achieved in at least two financial years in last five years in 2019-20 to 2023-24 a minimum financial Annual Turnover Certificate Dually Certified by Charted Accountant of Rs 640.00 lakhsTrueTechnical Bid
Satisfactory completed, at least one similar work on Building of value not less than Rs. 160.00 Lakhs as prime contractor in the last five years in 2019-20 to 2023-24TrueTechnical Bid
Executed in any one year for a continuous period of 12 months the following minimum quantities of workTrueTechnical Bid
Current Valid Class-1 PWD Civil License Registration CopyTrueTechnical Bid
Existing ongoing works Details Submit in Prescribed format in this DocumentTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs.96.00 LakhsTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsShivamoggaBhadravathiShimogaBHADRAVATHIHiriyuru Land Fil Site Bhadravathi-577301NoneNoneNoneNoneNoneNone
tenderAddress
createdTs1719582189000
version0
createdDateNone
modifiedDateNone
blockNumberCity Municipal Council TK Roakd Bhadravathi
streetNone
cityBhadravathi
stateKarnataka
pin577301
tenderRecallDTONone