| 1719488818000 | 1 | None | None | Buildings | Constructionn of Proposed 35TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At Hiriyuru land fill site in Bhadravthi CMC | 26022176.96 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3386477 | 119265 | None | Code01 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 105.06 | 105.06 | 285.89 | False | None | None | False | None | False | 30035.6034 | 0 | | 3386478 | 119265 | None | Code02 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 5833.92 | 5833.92 | 250.33 | False | None | None | False | None | False | 1460405.1936 | 0 | | 3386479 | 119265 | None | Code03 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for footting | Cum | 7208.35 | 7208.35 | 69.84 | False | None | None | False | None | False | 503431.164 | 0 | | 3386480 | 119265 | None | Code04 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for column pedestal and side wall | Cum | 11346.48 | 11346.48 | 32.78 | False | None | None | False | None | False | 371937.6144 | 0 | | 3386481 | 119265 | None | Code05 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for hall grade slab and ramp | Cum | 7208.35 | 7208.35 | 310.99 | False | None | None | False | None | False | 2241724.7665 | 0 | | 3386482 | 119265 | None | Code06 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 9789.12 | 9789.12 | 23.37 | False | None | None | False | None | False | 228771.7344 | 0 | | 3386483 | 119265 | None | Code07 | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR) | Tonne | 92140.71 | 92140.71 | 25.8281 | False | None | None | False | None | False | 2379819.471951 | 0 | | 3386484 | 119265 | None | Code08 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6580.67 | 6580.67 | 105.5 | False | None | None | False | None | False | 694260.685 | 0 | | 3386485 | 119265 | None | Code09 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 488.22 | 488.22 | 2508.38 | False | None | None | False | None | False | 1224641.2836 | 0 | | 3386486 | 119265 | None | Code10 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Sqm | 1267.93 | 1267.93 | 489.24 | False | None | None | False | None | False | 620322.0732 | 0 | | 3386487 | 119265 | None | Code11 | KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2) | Sqm | 303.85 | 303.85 | 1016.9 | False | None | None | False | None | False | 308985.065 | 0 | | 3386488 | 119265 | None | Code12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kg | 116.39 | 116.39 | 92800.0 | False | None | None | False | None | False | 10800992.0 | 0 | | 3386489 | 119265 | None | Code13 | Turbo fans
Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 0.9mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 5.2kg for Industrial use. (KPWD common SR2023-24 Vol 2, I.No 7.69.1 P.no 38) | No | 5376.6 | 5376.6 | 14.0 | False | None | None | False | None | False | 75272.4 | 0 | | 3386490 | 119265 | None | Code14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 585.04 | 585.04 | 3797.28 | False | None | None | False | None | False | 2221560.6912 | 0 | | 3386491 | 119265 | None | Code15 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 103.0 | 103.0 | 1016.9 | False | None | None | False | None | False | 104740.7 | 0 | | 3386492 | 119265 | None | Code16 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | Sqm | 75.19 | 75.19 | 497.06 | False | None | None | False | None | False | 37373.9414 | 0 | | 3386493 | 119265 | None | Code17 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | Sqm | 75.19 | 75.19 | 456.35 | False | None | None | False | None | False | 34312.9565 | 0 | | 3386494 | 119265 | None | Code18 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2711.99 | 2711.99 | 57.38 | False | None | None | False | None | False | 155613.9862 | 0 | | 3386495 | 119265 | None | Code19 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | No | 25426.58 | 25426.58 | 3.0 | False | None | None | False | None | False | 76279.74 | 0 | | 3386496 | 119265 | None | Code20 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kg | 465.56 | 465.56 | 1020.0 | False | None | None | False | None | False | 474871.2 | 0 | | 3386497 | 119265 | None | Code21 | Fabricating supplying and mounting MS box made out SWG
suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG .(KPWD common SR 2023-24 Item No. 5.42.2, Page No. 20, Vol.6) mani and sub panel | cm | 0.43 | 0.43 | 21600.0 | False | None | None | False | None | False | 9288.0 | 0 | | 3386498 | 119265 | None | Code22 | Supplying and fixing angle iron frame work fabricated out of M.S.
angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
50 x 50 x 6 mm.(KPWD common SR 2023-24 Item No. 5.41.2, Page No. 20, Vol.6) | Mtr | 395.0 | 395.0 | 27.0 | False | None | None | False | None | False | 10665.0 | 0 | | 3386499 | 119265 | None | Code23 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS
specification with necessary bolts, nuts and washers etc., complete
250 A 4 x 30 x 10 mm Aluminium Strips (KPWD common SR 2023-24 Item No. 5.40.2, Page No. 20, Vol.6) | Mtr | 3435.0 | 3435.0 | 12.0 | False | None | None | False | None | False | 41220.0 | 0 | | 3386500 | 119265 | None | Code24 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (KPWD common SR 2023-24 Item No. 5.15.16. Page No. 16,17, Vol.6) 400 A 36 kA MCCB FOUR Pole | Each | 28216.0 | 28216.0 | 1.0 | False | None | None | False | None | False | 28216.0 | 0 | | 3386501 | 119265 | None | Code25 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (KPWD common SR 2023-24 Item No. 5.15.9. Page No. 16,17, Vol.6) 100 A 25 kA FOUR Pole | Each | 8487.0 | 8487.0 | 2.0 | False | None | None | False | None | False | 16974.0 | 0 | | 3386502 | 119265 | None | Code26 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. (KPWD common SR 2023-24 Item No. 5.17.1. Page No. 17, Vol.6) 4 Way | Each | 10329.0 | 10329.0 | 2.0 | False | None | None | False | None | False | 20658.0 | 0 | | 3386503 | 119265 | None | Code27 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (KPWD common SR 2023-24 Item No. 5.18.3. Page No. 17, Vol.6) 50-63 A SP | Each | 811.0 | 811.0 | 11.0 | False | None | None | False | None | False | 8921.0 | 0 | | 3386504 | 119265 | None | Code28 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (KPWD common SR 2023-24 Item No. 5.19.5. Page No. 18, Vol.6) I - Single Door 16 Way SP & N | Each | 2932.0 | 2932.0 | 4.0 | False | None | None | False | None | False | 11728.0 | 0 | | 3386505 | 119265 | None | Code29 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. (KPWD common SR 2023-24 Item No. 5.20.10. Page No. 18, Vol.6) 63 A 4 pole | Each | 5545.0 | 5545.0 | 10.0 | False | None | None | False | None | False | 55450.0 | 0 | | 3386506 | 119265 | None | Code30 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. . (KPWD common SR 2023-24 Item No. 5.21. Page No. 18, Vol.6) | Each | 9255.0 | 9255.0 | 2.0 | False | None | None | False | None | False | 18510.0 | 0 | | 3386507 | 119265 | None | Code31 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter
on existing panel/wood board. (KPWD common SR 2023-24 Item No. 5.22. Page No. 18, Vol.6) | Each | 452.0 | 452.0 | 2.0 | False | None | None | False | None | False | 904.0 | 0 | | 3386508 | 119265 | None | Code32 | Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type
Ammeter (KPWD common SR 2023-24 Item No. 5.24. Page No. 18, Vol.6) | Each | 465.0 | 465.0 | 2.0 | False | None | None | False | None | False | 930.0 | 0 | | 3386509 | 119265 | None | Code33 | Supplying, fixing and wiring rotary selector switch suitable for
Ammeter (KPWD common SR 2023-24 Item No. 5.27. Page No. 19, Vol.6) | Each | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 | | 3386510 | 119265 | None | Code34 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter (KPWD common SR 2023-24 Item No. 5.29. Page No. 19, Vol.6) | Each | 1425.0 | 1425.0 | 2.0 | False | None | None | False | None | False | 2850.0 | 0 | | 3386511 | 119265 | None | Code35 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. (KPWD common SR 2023-24 Item No. 5.31. Page No. 19, Vol.6) | Each | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 | | 3386512 | 119265 | None | Code36 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (KPWD common SR 2023-24 Item No. 5.33. Page No. 19, Vol.6) | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 | | 3386513 | 119265 | None | Code37 | Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage,50HZ frequency and as per IS 60947-4-1. (KPWD common SR 2023-24 Item No. 5.52.1 Page No. 22, Vol.6) 12.5 KVAR | Each | 2901.0 | 2901.0 | 2.0 | False | None | None | False | None | False | 5802.0 | 0 | | 3386514 | 119265 | None | Code38 | Supplying and fixing HRC fuse units base on existing switch / panel board. (KPWD common SR 2023-24 Item No. 5.9.4 Page No. 15, Vol.6) 315 to 630 A | Each | 1212.0 | 1212.0 | 6.0 | False | None | None | False | None | False | 7272.0 | 0 | | 3386515 | 119265 | None | Code39 | Supplying and fixing HRC fuse link on existing switch fuse base with
W loss as per IS-13703. (KPWD common SR 2023-24 Item No. 5.10.5 Page No. 15, Vol.6) Above 425 A to 630 A | Each | 1148.0 | 1148.0 | 6.0 | False | None | None | False | None | False | 6888.0 | 0 | | 3386516 | 119265 | None | Code40 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. (KPWD common SR 2023-24 Item No. 5.14.6 Page No. 16, Vol.6) 95/100 A | Each | 16606.0 | 16606.0 | 2.0 | False | None | None | False | None | False | 33212.0 | 0 | | 3386517 | 119265 | None | Code41 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.16 Page No. 13, Vol.6) | Km | 554655.0 | 554655.0 | 0.15 | False | None | None | False | None | False | 83198.25 | 0 | | 3386518 | 119265 | None | Code42 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.13 Page No. 13, Vol.6) | Km | 317912.0 | 317912.0 | 0.12 | False | None | None | False | None | False | 38149.44 | 0 | | 3386519 | 119265 | None | Code43 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.12 Page No. 13, Vol.6) | Km | 207194.0 | 207194.0 | 0.12 | False | None | None | False | None | False | 24863.28 | 0 | | 3386520 | 119265 | None | Code44 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.08 Page No. 13, Vol.6) | Km | 179844.0 | 179844.0 | 0.1 | False | None | None | False | None | False | 17984.4 | 0 | | 3386521 | 119265 | None | Code45 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (KPWD common SR 2023-24 escom part II Item No. 32.05 Page No. 13, Vol.6) | Km | 141842.0 | 141842.0 | 0.15 | False | None | None | False | None | False | 21276.3 | 0 | | 3386522 | 119265 | None | Code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.3.6 Page No. 6, Vol.6) 4CX10 mm2 | Mtr | 167.0 | 167.0 | 180.0 | False | None | None | False | None | False | 30060.0 | 0 | | 3386523 | 119265 | None | Code47 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.3.5 Page No. 6, Vol.6) 4CX 6 mm2 | Mtr | 92.0 | 92.0 | 160.0 | False | None | None | False | None | False | 14720.0 | 0 | | 3386524 | 119265 | None | Code48 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.5.22 Page No. 7, Vol.6) 3CX6 mm2 | Mtr | 253.0 | 253.0 | 300.0 | False | None | None | False | None | False | 75900.0 | 0 | | 3386525 | 119265 | None | Code49 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 (KPWD common SR 2023-24 Item No. 2.5.15 Page No. 6, Vol.6) 3CX4 mm2 | Mtr | 172.0 | 172.0 | 250.0 | False | None | None | False | None | False | 43000.0 | 0 | | 3386526 | 119265 | None | Code50 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.11 Page No. 14, Vol.6) 185 Sqmm, 3.5/4 Core | Set | 1717.0 | 1717.0 | 8.0 | False | None | None | False | None | False | 13736.0 | 0 | | 3386527 | 119265 | None | Code51 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.08 Page No. 14, Vol.6) 70 Sqmm, 3.5/4 Core | Set | 1055.0 | 1055.0 | 8.0 | False | None | None | False | None | False | 8440.0 | 0 | | 3386528 | 119265 | None | Code52 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.07 Page No. 14, Vol.6) 50 Sqmm, 4 Core | Set | 855.0 | 855.0 | 8.0 | False | None | None | False | None | False | 6840.0 | 0 | | 3386529 | 119265 | None | Code53 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.06 Page No. 14, Vol.6) 25 Sqmm, 4 Core | Set | 750.0 | 750.0 | 10.0 | False | None | None | False | None | False | 7500.0 | 0 | | 3386530 | 119265 | None | Code54 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.04 Page No. 14, Vol.6) 16 Sqmm, 4 Core | Set | 698.0 | 698.0 | 12.0 | False | None | None | False | None | False | 8376.0 | 0 | | 3386531 | 119265 | None | Code55 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.02 Page No. 14, Vol.6) 10 Sqmm, 4 Core | Set | 698.0 | 698.0 | 14.0 | False | None | None | False | None | False | 9772.0 | 0 | | 3386532 | 119265 | None | Code56 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34. 14 Page No. 15, Vol.6) 6 Sqmm, 4 Core | Set | 630.0 | 630.0 | 14.0 | False | None | None | False | None | False | 8820.0 | 0 | | 3386533 | 119265 | None | Code57 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.14 Page No. 15, Vol.6) up to 6 Sqmm | Set | 630.0 | 630.0 | 16.0 | False | None | None | False | None | False | 10080.0 | 0 | | 3386534 | 119265 | None | Code58 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 (KPWD common SR 2023-24 hescom part II Item No. 34.14 Page No. 15, Vol.6) up to 6 Sqmm | Set | 630.0 | 630.0 | 12.0 | False | None | None | False | None | False | 7560.0 | 0 | | 3386535 | 119265 | None | Code59 | Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm (KPWD common SR 2023-24 hescom part II Item No. 59.04 Page No. 26, Vol.6) | No | 89.0 | 89.0 | 24.0 | False | None | None | False | None | False | 2136.0 | 0 | | 3386536 | 119265 | None | Code60 | Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 59.01 Page No. 26, Vol.6) | No | 27.0 | 27.0 | 24.0 | False | None | None | False | None | False | 648.0 | 0 | | 3386537 | 119265 | None | Code61 | Heavy Duty Copper Terminal Long Barrel 16 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.02 Page No. 27, Vol.6) | No | 2.0 | 2.0 | 24.0 | False | None | None | False | None | False | 48.0 | 0 | | 3386538 | 119265 | None | Code62 | Heavy Duty Copper Terminal Long Barrel 10 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6) | No | 2.0 | 2.0 | 24.0 | False | None | None | False | None | False | 48.0 | 0 | | 3386539 | 119265 | None | Code63 | Heavy Duty Copper Terminal Long Barrel 6 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6) | No | 2.0 | 2.0 | 24.0 | False | None | None | False | None | False | 48.0 | 0 | | 3386540 | 119265 | None | Code64 | Heavy Duty Copper Terminal Long Barrel 4 Sqmm Copper Terminal, Apprx Wt: 11 Gm (KPWD common SR 2023-24 hescom part II Item No. 60.01 Page No. 27, Vol.6) | No | 2.0 | 2.0 | 24.0 | False | None | None | False | None | False | 48.0 | 0 | | 3386541 | 119265 | None | Code65 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.05 Page No. 59, Vol.6) | Km | 20886.0 | 20886.0 | 0.15 | False | None | None | False | None | False | 3132.9 | 0 | | 3386542 | 119265 | None | Code66 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.06 Page No. 59, Vol.6) | Km | 31139.0 | 31139.0 | 0.34 | False | None | None | False | None | False | 10587.26 | 0 | | 3386543 | 119265 | None | Code67 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm (KPWD common SR 2023-24 escom part II Item No. 21.07 Page No. 59, Vol.6) | Km | 32278.0 | 32278.0 | 0.15 | False | None | None | False | None | False | 4841.7 | 0 | | 3386544 | 119265 | None | Code68 | Heat shrinkable Straight Through Joint 2.5 to 25 Sqmm (KPWD common SR 2023-24 escom part II Item No. 22.09 Page No. 59, Vol.6) | Set | 143.0 | 143.0 | 8.0 | False | None | None | False | None | False | 1144.0 | 0 | | 3386545 | 119265 | None | Code69 | Heat shrinkable Straight Through Joint 35 to 95 Sqmm(KPWD common SR 2023-24 escom part II Item No. 22.10 Page No. 59, Vol.6) | Set | 284.0 | 284.0 | 24.0 | False | None | None | False | None | False | 6816.0 | 0 | | 3386546 | 119265 | None | Code70 | Heat shrinkable Straight Through Joint 120 to 240 Sqmm (KPWD common SR 2023-24 escom part II Item No. 22.10 Page No. 59, Vol.6) | Set | 380.0 | 380.0 | 8.0 | False | None | None | False | None | False | 3040.0 | 0 | | 3386547 | 119265 | None | Code71 | RCC Hume Pipe 2000 mm long 200 mm Dia (KPWD common SR 2023-24 escom part II Item No. 68.02 Page No. 30, Vol.6) | No | 390.0 | 390.0 | 65.0 | False | None | None | False | None | False | 25350.0 | 0 | | 3386548 | 119265 | None | Code72 | Collars for RCC Hume Pipe 200 mm Dia (KPWD common SR 2023-24 escom part II Item No. 68.02 Page No. 30, Vol.6) | No | 103.0 | 103.0 | 65.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3386549 | 119265 | None | Code73 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. (KPWD common SR 2023-24 Item No.5.14.6 Page No. 16, Vol.6) | No | 16606.0 | 16606.0 | 2.0 | False | None | None | False | None | False | 33212.0 | 0 | | 3386550 | 119265 | None | Code74 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (KPWD common SR 2023-24 Item No.29.03 Page No. 63, Vol.6) UG cable work In Hard Soil | Cum | 389.0 | 389.0 | 460.7999 | False | None | None | False | None | False | 179251.1611 | 0 | | 3386551 | 119265 | None | Code75 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (KPWD common SR 2023-24 Item No.29.07 Page No. 63, Vol.6) UG cable work | Cum | 58.0 | 58.0 | 288.0 | False | None | None | False | None | False | 16704.0 | 0 | | 3386552 | 119265 | None | Code76 | Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure. (KPWD common SR 2023-24 KPTCL section Item No.3 Page No.158, Vol.6) UG cable work | Cum | 1965.0 | 1965.0 | 96.0 | False | None | None | False | None | False | 188640.0 | 0 | | 3386553 | 119265 | None | Code77 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit | Mtr | 69.0 | 69.0 | 1000.0 | False | None | None | False | None | False | 69000.0 | 0 | | 3386554 | 119265 | None | Code78 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2 , 25mm dia PVC 2mm thick conduit | Mtr | 81.0 | 81.0 | 1000.0 | False | None | None | False | None | False | 81000.0 | 0 | | 3386555 | 119265 | None | Code79 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2 , 32mm dia PVC 2mm thick conduit | Mtr | 106.0 | 106.0 | 600.0 | False | None | None | False | None | False | 63600.0 | 0 | | 3386556 | 119265 | None | Code80 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2 , 40mm dia PVC 2mm thick conduit | Mtr | 149.0 | 149.0 | 800.0 | False | None | None | False | None | False | 119200.0 | 0 | | 3386557 | 119265 | None | Code81 | Point wiring using Copper wire with switch
Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-2, PAGE NO-5 | Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 3386558 | 119265 | None | Code82 | Point wiring using Copper wire with switch
Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 3M upto 6Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-2, PAGE NO-5 | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 3386559 | 119265 | None | Code83 | Point wiring using Copper wire with switch
Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 6M upto 10Mtr from switch board , CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-2, PAGE NO-5 | Point | 570.0 | 570.0 | 17.0 | False | None | None | False | None | False | 9690.0 | 0 | | 3386560 | 119265 | None | Code84 | Point wiring using Copper wire with switch
Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-5 | Point | 708.0 | 708.0 | 2.0 | False | None | None | False | None | False | 1416.0 | 0 | | 3386561 | 119265 | None | Code85 | Point wiring using Copper wire with switch
Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch board, CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-5 | Point | 1035.0 | 1035.0 | 8.0 | False | None | None | False | None | False | 8280.0 | 0 | | 3386562 | 119265 | None | Code86 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-2, PAGE NO-5 | Mtr | 19.0 | 19.0 | 800.0 | False | None | None | False | None | False | 15200.0 | 0 | | 3386563 | 119265 | None | Code87 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 1.50 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-2, PAGE NO-5 | Mtr | 26.0 | 26.0 | 800.0 | False | None | None | False | None | False | 20800.0 | 0 | | 3386564 | 119265 | None | Code88 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 2.50 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-2, PAGE NO-5 | Mtr | 42.0 | 42.0 | 800.0 | False | None | None | False | None | False | 33600.0 | 0 | | 3386565 | 119265 | None | Code89 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010,. 4.00 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-2, PAGE NO-5 | Mtr | 63.0 | 63.0 | 600.0 | False | None | None | False | None | False | 37800.0 | 0 | | 3386566 | 119265 | None | Code90 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010, 6.00 Sqmm Cu FRLS wire ,CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-2, PAGE NO-5 | Mtr | 92.0 | 92.0 | 400.0 | False | None | None | False | None | False | 36800.0 | 0 | | 3386567 | 119265 | None | Code91 | Supplying and fixing of modular switch & connected accessories on
Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 | No | 102.0 | 102.0 | 25.0 | False | None | None | False | None | False | 2550.0 | 0 | | 3386568 | 119265 | None | Code92 | Supplying and fixing of modular switch & connected accessories on
Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 | No | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 | | 3386569 | 119265 | None | Code93 | Supplying and fixing of modular switch & connected accessories on
Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9 | No | 357.0 | 357.0 | 20.0 | False | None | None | False | None | False | 7140.0 | 0 | | 3386570 | 119265 | None | Code94 | Supplying and fixing of modular switch & connected accessories on
Existing modular switch plate as per IS 3854 and IS 1293.,CSR Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9 | No | 236.0 | 236.0 | 20.0 | False | None | None | False | None | False | 4720.0 | 0 | | 3386571 | 119265 | None | Code95 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater-than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater-than IK08. Power Factor Greater-than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency Greater-than 1301m/w, nominal CRI Greater-than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
,CSR Electrical SR-2023-24, ITEM NO:11.9.2 ,CH-11, PAGE NO-46 | No | 9486.0 | 9486.0 | 20.0 | False | None | None | False | None | False | 189720.0 | 0 | | 3386572 | 119265 | None | Code96 | Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) (KPWD common SR 2023-24 KPTCL section Item No.22.a.ii Page No.120, Vol.6) celing cable work | Mtr | 754.0 | 754.0 | 85.0 | False | None | None | False | None | False | 64090.0 | 0 |
|