tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719581586000 | 0 | None | None | Buildings | Construction of Toilet and Building to Govt. Girls P.U College at Old Jewargi Road in Kalaburagi City under KKRDB Micro for the year 2020-21 | 2816784.46 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3404570 | 120202 | None | Vol-I I No. 2.5.1 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7100.73 | 7100.73 | 8.63 | False | None | None | False | None | False | 61279.2999 | 0 | 3404571 | 120202 | None | Vol-I S R Sl no. 9 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70% | Cum | 4970.51 | 4970.51 | 8.63 | False | None | None | False | None | False | 42895.5013 | 0 | 3404572 | 120202 | None | Vol-I I No. 2.5.1 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7100.73 | 7100.73 | 17.01 | False | None | None | False | None | False | 120783.4173 | 0 | 3404573 | 120202 | None | Vol-I S R Sl no. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60% | Cum | 4260.44 | 4260.44 | 17.01 | False | None | None | False | None | False | 72470.0844 | 0 | 3404574 | 120202 | None | Vol-I I No. 2.5.1 Page no. 16 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7100.73 | 7100.73 | 25.95 | False | None | None | False | None | False | 184263.9435 | 0 | 3404575 | 120202 | None | Vol-I S R SL No. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50% | Cum | 3550.36 | 3550.36 | 25.95 | False | None | None | False | None | False | 92131.842 | 0 | 3404576 | 120202 | None | Vol 1 SR It No. 2.5.1 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7100.73 | 7100.73 | 0.47 | False | None | None | False | None | False | 3337.3431 | 0 | 3404577 | 120202 | None | Vol-I S R Sl No. 19 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of
minor sections add 45% | Cum | 3195.33 | 3195.33 | 0.47 | False | None | None | False | None | False | 1501.8051 | 0 | 3404578 | 120202 | None | Vol 1 SR It No. 2.11 a Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 95808.45 | 95808.45 | 5.51 | False | None | None | False | None | False | 527904.5595 | 0 | 3404579 | 120202 | None | Vol-II I No. 6.8 Page No. 14 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8534.8 | 8534.8 | 51.25 | False | None | None | False | None | False | 437408.5 | 0 | 3404580 | 120202 | None | Vol-II I No. 12.12 Page No. 99 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and side
clamps ), but including cost of materials, labour, usage charges complete
as per specifications. | Cum | 133020.34 | 133020.34 | 0.59 | False | None | None | False | None | False | 78482.0006 | 0 | 3404581 | 120202 | None | Vol-II I No. 11.34A Page No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 179.93 | 179.93 | 283.5 | False | None | None | False | None | False | 51010.155 | 0 | 3404582 | 120202 | None | Vol-II I No. 8.34.3 Page No. 47 | Applying priming coat: With ready mixed red oxide zinc chromate
primer of approved brand and manufacture on steel galvanised iron/
steel works including preparing the surface after thorougly cleaning oil,
grease, dirt and foreign matter, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 53.55 | 53.55 | 35.1 | False | None | None | False | None | False | 1879.605 | 0 | 3404583 | 120202 | None | Vol-II I No. 8.40 Page No. 48 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 123.16 | 123.16 | 35.1 | False | None | None | False | None | False | 4322.916 | 0 | 3404584 | 120202 | None | Vol-II I No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications | No | 1088.14 | 1088.14 | 2.0 | False | None | None | False | None | False | 2176.28 | 0 | 3404585 | 120202 | None | Vol-II I No. 12.52 Page No. 104 | Fixing of window frame in an existing opening including embedding frame
in floor and walls after cutting masonry for holdfasts for embedding
holdfast in cement concrete 1:3:6 of 20mm and down size granite metal
painting two coats of coal tar to sides of frame, making good the damages
to walls and floor as required and disposal of the debries with lead
upto 50 m. including cost of materials, labour charges, complete as per
specifications. | No | 827.88 | 827.88 | 5.0 | False | None | None | False | None | False | 4139.4 | 0 | 3404586 | 120202 | None | Vol-II I No. 8.5.2 Page No. 42 | Providing 15 mm cement plaster on rough side of single or half brick
wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 373.78 | 373.78 | 258.98 | False | None | None | False | None | False | 96801.5444 | 0 | 3404587 | 120202 | None | Vol-II I No. 8.9 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 412.33 | 412.33 | 321.17 | False | None | None | False | None | False | 132428.0261 | 0 | 3404588 | 120202 | None | Vol-II I No 8.1.2 Page No. 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:
6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 258.11 | 258.11 | 137.5 | False | None | None | False | None | False | 35490.125 | 0 | 3404589 | 120202 | None | Vol-II I No. 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 107.1 | 107.1 | 363.98 | False | None | None | False | None | False | 38982.258 | 0 | 3404590 | 120202 | None | Vol-II I No. 9.34 Page No. 64 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. | Sqm | 1654.69 | 1654.69 | 139.5 | False | None | None | False | None | False | 230829.255 | 0 | 3404591 | 120202 | None | Vol-II I No. 12.18 Page No. 100 | Providing and fixing in position fully panelled Matti/Nandi wood shutters
for doors with, stiles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures ) | Sqm | 7042.9 | 7042.9 | 2.88 | False | None | None | False | None | False | 20283.552 | 0 | 3404592 | 120202 | None | Vol-II I No. 12.32 Page No. 101 | Providing and fixing in position Mathi / Nandi wood fully panelled shutters
for windows with stiles and rails of 25mm. thick, 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 6256.78 | 6256.78 | 10.8 | False | None | None | False | None | False | 67573.224 | 0 | 3404593 | 120202 | None | Vol-II I No. 8.25 Page No. 45 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including
water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 146.73 | 146.73 | 363.98 | False | None | None | False | None | False | 53406.7854 | 0 | 3404594 | 120202 | None | Vol-II I No. 8.30 Page No. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 186.35 | 186.35 | 329.65 | False | None | None | False | None | False | 61430.2775 | 0 | 3404595 | 120202 | None | Vol-II I No. 8.34.1 Page No. 47 | Applying priming coat: With ready mixed pink or Grey primer of
approved brand and manufacture on wood work (hard and soft wood)
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, cost of materials, labour complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 56.76 | 56.76 | 34.63 | False | None | None | False | None | False | 1965.5988 | 0 | 3404596 | 120202 | None | Vol-II I No. 8.33.2 Page No. 46 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.8 | 147.8 | 35.57 | False | None | None | False | None | False | 5257.246 | 0 | 3404597 | 120202 | None | Vol-II I no. 15.1 Page No. 149 | Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing
membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. | Sqm | 875.01 | 875.01 | 115.5 | False | None | None | False | None | False | 101063.655 | 0 | 3404598 | 120202 | None | Vol-II I No. 11.28 Page No. 85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 605.11 | 605.11 | 60.0 | False | None | None | False | None | False | 36306.6 | 0 | 3404599 | 120202 | None | Vol-III I No. 8.7 Page No. 65 | Providing and erecting direction and place identification retroreflectorised
sign as per IRC:67:2022 made of high intensity
grade sheeting vide clause 801.3, fixed over aluminium
sheeting, 2 mm thick or Aluminium composite material sheet
with overall thickness of 4mm with area not exceeding 0.9
m2 fixed over back support frame of min 35 x 35 x 3mm angle
mounted on a mild steel circular pipe 65 NB, firmly fixed to the
ground by means of properly designed foundation with M25
grade cement concrete 45 x 45 x 60 cm, 60 cm below ground
level as per approved drawing | Sqm | 9649.71 | 9649.71 | 1.2 | False | None | None | False | None | False | 11579.652 | 0 | 3404600 | 120202 | None | GeM Rate | hmp Three seater classroom desking drawing | Each | 8900.0 | 8900.0 | 26.0 | False | None | None | False | None | False | 231400.0 | 0 | 3404601 | 120202 | None | Approved Rate | KKRDB Name Board | Each | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
| 1719581586000 | 0 | None | None | Buildings | ELECTRICAL WORK | 164329.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3404602 | 120203 | None | Vol 6 SR It No. 1.2.1 Page No. 2 of 105 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 250.0 | False | None | None | False | None | False | 16500.0 | 0 | 3404603 | 120203 | None | Vol 6 SR It No. 1.3.2 Page No. 2 of 105 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 250.0 | False | None | None | False | None | False | 19750.0 | 0 | 3404604 | 120203 | None | Vol 6 SR It No. 1.5.2 Page No. 3 of 105 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 8.0 | False | None | None | False | None | False | 448.0 | 0 | 3404605 | 120203 | None | Vol 6 SR It No. 1.6.3 Page No. 3 of 105 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 10" x 7" x 3" (254 x 178 x 76 mm) | Each | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 3404606 | 120203 | None | Vol 6 SR It No. 1.13 Page No. 4 of 105 | Supplying And Fixing Metal Fan Box with Round Hook. | Each | 117.0 | 117.0 | 6.0 | False | None | None | False | None | False | 702.0 | 0 | 3404607 | 120203 | None | Vol 6 SR It No. 2.1.1 Page No. 5 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Short point upto 3Mtr from tapping point to out let via switch | Each | 285.0 | 285.0 | 12.0 | False | None | None | False | None | False | 3420.0 | 0 | 3404608 | 120203 | None | Vol 6 SR It No. 2.1.2 Page No. 5 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Each | 394.0 | 394.0 | 12.0 | False | None | None | False | None | False | 4728.0 | 0 | 3404609 | 120203 | None | Vol 6 SR It No. 2.1.3 Page No. 5 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Each | 570.0 | 570.0 | 12.0 | False | None | None | False | None | False | 6840.0 | 0 | 3404610 | 120203 | None | Vol 6 SR It No. 2.5.2 Page No. 6 of 105 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 1.5 mm2 | m | 72.0 | 72.0 | 250.0 | False | None | None | False | None | False | 18000.0 | 0 | 3404611 | 120203 | None | Vol 6 SR It No. 2.5.3 Page No. 6 of 105 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 4C x 1.5 mm2 | m | 94.0 | 94.0 | 250.0 | False | None | None | False | None | False | 23500.0 | 0 | 3404612 | 120203 | None | Vol 6 SR It No. 3.1.1 Page No. 8 of 105 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way | Each | 128.0 | 128.0 | 8.0 | False | None | None | False | None | False | 1024.0 | 0 | 3404613 | 120203 | None | Vol 6 SR It No. 3.14.2 Page No. 10 of 105 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Two Way Switch | Each | 70.0 | 70.0 | 8.0 | False | None | None | False | None | False | 560.0 | 0 | 3404614 | 120203 | None | Vol 6 SR It No. 3.5.1 Page No. 8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 1 to 2 Module | Each | 137.0 | 137.0 | 20.0 | False | None | None | False | None | False | 2740.0 | 0 | 3404615 | 120203 | None | Vol 6 SR It No. 3.5.4 Page No. 8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 20.0 | False | None | None | False | None | False | 4680.0 | 0 | 3404616 | 120203 | None | Vol 6 SR It No. 3.9 Page No. 9 of 105 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws | Sq CM | 0.35 | 0.35 | 80000.0 | False | None | None | False | None | False | 28000.0 | 0 | 3404617 | 120203 | None | Vol 6 SR It No. 6.3.1 Page No. 30 of 105 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 6.0 | False | None | None | False | None | False | 17904.0 | 0 | 3404618 | 120203 | None | Vol 6 SR It No. 11.14.1 Page No. 47 of 105 | Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. | Each | 361.0 | 361.0 | 16.0 | False | None | None | False | None | False | 5776.0 | 0 | 3404619 | 120203 | None | Vol 6 SR It No. 13.7.1 Page No. 56 of 105 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 16.0 | False | None | None | False | None | False | 1952.0 | 0 | 3404620 | 120203 | None | Vol 6 SR It No. 13.11 Page No. 57 of 105 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 6.0 | False | None | None | False | None | False | 1890.0 | 0 | 3404621 | 120203 | None | Vol 6 SR It No. 5.19.12 Page No. 18 of 105 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 6 Way TP & N | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 3404622 | 120203 | None | Vol 6 SR It No. 5.18.1 Page No. 17 of 105 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
|
|
---|