tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719307330000 | 1 | None | None | Buildings | CONSTRUCTION OF AUDITORIUM, PROVIDING PROJECTOR 5, XEROX MACHINE-02, UPS WITH BATTERY, GENERATOR TO S.A.V.T. GOVT FIRST GRADE COLLEGE (SCP-119.30 LC) Work code-VNR22411503261 | 8325719.24 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346171 | 117609 | None | CSR For 2023-24 Item No 1.12 Page No 08 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth
| Cum | 99.75 | 99.75 | 50.0 | False | None | None | False | None | False | 4987.5 | 0 | 3346172 | 117609 | None | CSR For 2023-24 Item No 1.14.1 Page No 08 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 250.73 | False | None | None | False | None | False | 26853.183 | 0 | 3346173 | 117609 | None | CSR For 2023-24 Item No 2.1.3 Page No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 92.65 | False | None | None | False | None | False | 582624.8925 | 0 | 3346174 | 117609 | None | CSR For 2023-24 Item No 2.2.1 Page No 15 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6601.35 | 6601.35 | 9.13 | False | None | None | False | None | False | 60270.3255 | 0 | 3346175 | 117609 | None | CSR For 2023-24 Item No 5.4 Page No 09 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6708.45 | 6708.45 | 94.5 | False | None | None | False | None | False | 633948.525 | 0 | 3346176 | 117609 | None | CSR For 2023-24 Iteam No 2.3.1 Page No 16 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6639.15 | 6639.15 | 13.74 | False | None | None | False | None | False | 91221.921 | 0 | 3346177 | 117609 | None | CSR For 2023-24 Item No 2.5.1 Page No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 15.32 | False | None | None | False | None | False | 106650.18 | 0 | 3346178 | 117609 | None | CSR For 2023-24 Item No 1.8 Page No 07 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 497.7 | 497.7 | 533.99 | False | None | None | False | None | False | 265766.823 | 0 | 3346179 | 117609 | None | CSR For 2023-24 Item No 2.5.1 Page No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 19.82 | False | None | None | False | None | False | 137976.93 | 0 | 3346180 | 117609 | None | CSR For 2023-24 Item No 2.5.1 Page No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 16.8 | False | None | None | False | None | False | 116953.2 | 0 | 3346181 | 117609 | None | CSR For 2023-24 Item No 2.5.1 Page No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6961.5 | 6961.5 | 0.62 | False | None | None | False | None | False | 4316.13 | 0 | 3346182 | 117609 | None | CSR For 2023-24 Item No 2.11a Page No 18 | Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
Buildings
| t | 93929.85 | 93929.85 | 10.36 | False | None | None | False | None | False | 973113.246 | 0 | 3346183 | 117609 | None | CSR For 2023-24 Item No 6.32 Page No 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1375.5 | 1375.5 | 427.26 | False | None | None | False | None | False | 587696.13 | 0 | 3346184 | 117609 | None | CSR For 2023-24 Item No 2.1.4 Page No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6527.85 | 6527.85 | 3.12 | False | None | None | False | None | False | 20366.892 | 0 | 3346185 | 117609 | None | CSR For 2023-24 Item No 8.1.2 Page No 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 602.52 | False | None | None | False | None | False | 152467.686 | 0 | 3346186 | 117609 | None | CSR For 2023-24 Item No 8.3.2 Page No 41 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 349.65 | 349.65 | 698.82 | False | None | None | False | None | False | 244342.413 | 0 | 3346187 | 117609 | None | CSR For 2023-24 Item No 12.13.1 Page No 100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 103755.75 | 103755.75 | 0.59 | False | None | None | False | None | False | 61215.8925 | 0 | 3346188 | 117609 | None | CSR For 2023-24 Item No 12.51 Page No 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost ofmaterials, labourcharges, complete as per specifications.
| No | 1066.8 | 1066.8 | 9.0 | False | None | None | False | None | False | 9601.2 | 0 | 3346189 | 117609 | None | CSR For 2023-24 Item No 12.17 Page No 100 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 7439.25 | 7439.25 | 19.8 | False | None | None | False | None | False | 147297.15 | 0 | 3346190 | 117609 | None | CSR For 2023-24 Item No 12.58 Page No 105 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
| No | 126.0 | 126.0 | 9.0 | False | None | None | False | None | False | 1134.0 | 0 | 3346191 | 117609 | None | CSR For 2023-24 Item No 12.59 Page No 105 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1169.7 | 1169.7 | 9.0 | False | None | None | False | None | False | 10527.3 | 0 | 3346192 | 117609 | None | CSR For 2023-24 Item No 12.60 Page No 105 | Providing andfixing chromium plated brass100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1104.6 | 1104.6 | 9.0 | False | None | None | False | None | False | 9941.4 | 0 | 3346193 | 117609 | None | CSR For 2023-24 Item No 12.61 Page No 105 | Providing and fixing chromium plated brass nightlatch of approved quality including necessary screws etc. complete.
| No | 1039.5 | 1039.5 | 9.0 | False | None | None | False | None | False | 9355.5 | 0 | 3346194 | 117609 | None | CSR For 2023-24 Item No 12.63 Page No 105 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
| No | 136.5 | 136.5 | 18.0 | False | None | None | False | None | False | 2457.0 | 0 | 3346195 | 117609 | None | CSR For 2023-24 Item No 12.68.2 Page No 106 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 100x58x1.9mm
| No | 45.15 | 45.15 | 27.0 | False | None | None | False | None | False | 1219.05 | 0 | 3346196 | 117609 | None | CSR For 2023-24 Item No 12.90 Page No 110 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through- out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7070.7 | 7070.7 | 35.52 | False | None | None | False | None | False | 251151.264 | 0 | 3346197 | 117609 | None | CSR For 2023-24 Item No 12.85 Page No 109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made
| Sqm | 6004.95 | 6004.95 | 1.08 | False | None | None | False | None | False | 6485.346 | 0 | 3346198 | 117609 | None | CSR For 2023-24 Item No 11.34B Page No 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
| Kg | 192.15 | 192.15 | 823.24 | False | None | None | False | None | False | 158185.566 | 0 | 3346199 | 117609 | None | CSR For 2023-24 Item No 11.28 Page No 85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessoriessuchasnuts, bolts, fastenersetc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 593.25 | 593.25 | 115.5 | False | None | None | False | None | False | 68520.375 | 0 | 3346200 | 117609 | None | CSR For 2023-24 Item No 9.24 Page No 63 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 2994.6 | 2994.6 | 80.04 | False | None | None | False | None | False | 239687.784 | 0 | 3346201 | 117609 | None | CSR For 2023-24 Item No 9.12.3 Page No 60 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS:15622,ofapprovedmake, in all coloursandshades,laidon 20mmthick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x800 mm
| Sqm | 1319.85 | 1319.85 | 351.07 | False | None | None | False | None | False | 463359.7395 | 0 | 3346202 | 117609 | None | CSR For 2023-24 Item No 9.9 Page No 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.
| Sqm | 1129.8 | 1129.8 | 5.98 | False | None | None | False | None | False | 6756.204 | 0 | 3346203 | 117609 | None | CSR For 2023-24 Item No 9.39 Page No 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1521.45 | 1521.45 | 26.8 | False | None | None | False | None | False | 40774.86 | 0 | 3346204 | 117609 | None | CSR For 2023-24 Item No 8.51 Page No 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 105.0 | 105.0 | 604.41 | False | None | None | False | None | False | 63463.05 | 0 | 3346205 | 117609 | None | CSR For 2023-24 Item No 8.39 Page No 48 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 133.35 | 133.35 | 604.41 | False | None | None | False | None | False | 80598.0735 | 0 | 3346206 | 117609 | None | CSR For 2023-24 Item No 8.30 Page No 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Twocoat applied@ 1.67L/10m² overandincluding priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 182.7 | 182.7 | 700.71 | False | None | None | False | None | False | 128019.717 | 0 | 3346207 | 117609 | None | CSR For 2023-24 Item No 8.40 Page No 48 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 120.75 | 120.75 | 100.97 | False | None | None | False | None | False | 12192.1275 | 0 | 3346208 | 117609 | None | CSR For 2023-24 Item No 8.3 Page No 63 | Printing New Letter and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade
| Height | 1.68 | 1.68 | 700.0 | False | None | None | False | None | False | 1176.0 | 0 | 3346209 | 117609 | None | CSR For 2023-24 Item No 69 Page No 134 | Preparation of Autocad drawing with colour print for Building / Bridge / Road/ CD Works in required size etc. complete. A-2 Size
| Nos | 3045.0 | 3045.0 | 6.0 | False | None | None | False | None | False | 18270.0 | 0 | 3346210 | 117609 | None | CSR For 2023-24 Item No 73 Page No 134 | Autocad drawing with colour print out for Building / Bridge / Road/ CD Works in required size etc. complete. A-3 Size
| Nos | 21.0 | 21.0 | 36.0 | False | None | None | False | None | False | 756.0 | 0 | 3346211 | 117609 | None | CSR For 2023-24 Item No 4.1 Page No 05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| 1 * 6 Reels | 123.9 | 123.9 | 420.0 | False | None | None | False | None | False | 52038.0 | 0 | 3346212 | 117609 | None | CSR For 2023-24 Item No 7.53 Page No 32 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, ColourWhite, Fire Performance UK Class0I Class1(BS 476pt- 6&7) with sand texture finish andsuitable for Green Building application with Recycled content of 47%. The tile shallbe laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 g/m2 and need to be installed with Suspension system.
| Sqm | 2824.5 | 2824.5 | 271.01 | False | None | None | False | None | False | 765467.745 | 0 | 3346213 | 117609 | None | CSR For 2023-24 Item No 11.16.1 Page No 82 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 142.8 | 142.8 | 8100.61 | False | None | None | False | None | False | 1156767.108 | 0 | 3346214 | 117609 | None | CSR For 2023-24 Item No 7.38 Page No 26 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheetshallbe fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
| Sqm | 596.4 | 596.4 | 451.43 | False | None | None | False | None | False | 269232.852 | 0 | 3346215 | 117609 | None | Common DSR For 2023-24 Volume I 2.2.1 P.No. 15 | Add Formwork/Centering Charges Vide Common DSR P.No.111 Vol-I Sl No a For a.Isolated at 8%
| Cum | 528.11 | 528.11 | 9.13 | False | None | None | False | None | False | 4821.6443 | 0 | 3346216 | 117609 | None | Common DSR For 2023-24 Volume I 2.3.1P.No. 16 | Add Formwork/Centering Charges Vide Common DSR P.No.111 Vol-I Sl No 2 For Plinth Beams of Buildings at 50% | Cum | 3319.58 | 3319.58 | 13.74 | False | None | None | False | None | False | 45611.0292 | 0 | 3346217 | 117609 | None | Common DSR For 2023-24 Volume I 2.5.1 P.No. 16 | Add Formwork/Centering Charges Vide Common DSR P.No.112 Vol-I Sl No 14 For RCC Beams, Lintels & Troughs of Aqueducts at 60% | Cum | 4176.9 | 4176.9 | 19.82 | False | None | None | False | None | False | 82786.158 | 0 | 3346218 | 117609 | None | Common DSR For 2023-24 Volume I 2.5.1 P.No. 16 | Add Formwork/Centering Charges Vide Common DSR P.No.111 Vol-I Sl No a For a.Isolated at 50% | Cum | 3480.75 | 3480.75 | 16.8 | False | None | None | False | None | False | 58476.6 | 0 | 3346219 | 117609 | None | Common DSR For 2023-24 Volume I 2.5.1 P.No. 16 | Add Formwork/Centering Charges Vide Common DSR P.No.112 Vol-I Sl No 19 For Chejjas, Canopy & Other Architectural projections of
minor sections at 0.45 | Cum | 3132.68 | 3132.68 | 0.62 | False | None | None | False | None | False | 1942.2616 | 0 | 3346220 | 117609 | None | Common DSR For 2023-24 Volume I 2.1.4 P.No. 15 | Add Formwork/Centering Charges Vide Common DSR P.No.112 Vol-I Sl No 14 For RCC Beams, Lintels & Troughs of Aqueducts at 60%
| Cum | 3916.71 | 3916.71 | 3.12 | False | None | None | False | None | False | 12220.1352 | 0 | 3346221 | 117609 | None | Common DSR For 2023-24 Volume I 2.5.1 P.No. 16 | Add Formwork/Centering Charges Vide Common DSR P.No.111 Vol-I Sl No 9 For RCC Columns / Shaft (Slip Centering) at 70%
| Cum | 4873.05 | 4873.05 | 15.32 | False | None | None | False | None | False | 74655.126 | 0 |
| 1719307330000 | 0 | None | None | Buildings | CONSTRUCTION OF AUDITORIUM, PROVIDING PROJECTOR 5, XEROX MACHINE-02, UPS WITH BATTERY, GENERATOR TO S.A.V.T. GOVT FIRST GRADE COLLEGE (TSP-27.53 Lakhs) | 2130581.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346222 | 117610 | None | GEM Rate | UnbrandedAUDITARIUM CHAIR 450 millimeter 460mm The sliding mechanism is fabricated from MS sheets forming linkages providing a 4-bar synchronous motion for the seat Product id: 5116877-70983414703, Backrest width 10mm450mmBackrest height 10mm625mm, Arms to arms inner width 10mm530 mm, Backrest to floor height 10mm900 millimeter Warrantee period in number of years1YEAR | Each | 6150.0 | 6150.0 | 240.0 | False | None | None | False | None | False | 1476000.0 | 0 | 3346223 | 117610 | None | GEM Rate | xerox Multifunction Machines Mfm, On Site OEM Warranty 1 Year xeroxR (Xerox Versalink B7125 (25 PPM, Mono) + 2 Tray + WiFi + 320B HDD with 1 Year Warranty)
| Each | 191322.4 | 191322.4 | 1.0 | False | None | None | False | None | False | 191322.4 | 0 | 3346224 | 117610 | None | GEM Rate | SUN ENERGY INDIA ENTERPRISES 6 20 Watt White LED type SUN ENERGY INDIA ENTERPRISESR (SUN ENERGY)
| Each | 20910.0 | 20910.0 | 10.0 | False | None | None | False | None | False | 209100.0 | 0 | 3346225 | 117610 | None | GEM Rate | BenQ Standard Throw (0.91 to 2.5) Multimedia Projector (MMP) With 1024 x 768 (XGA) Resolution
BenQR (MX550)
| Each | 36891.8 | 36891.8 | 5.0 | False | None | None | False | None | False | 184459.0 | 0 | 3346226 | 117610 | None | GEM Rate | acer Intel Core i5 10400 8 GB/ 1000 GB HDD/ DOS acerR (Veriton S2670G)
| Each | 69700.0 | 69700.0 | 1.0 | False | None | None | False | None | False | 69700.0 | 0 |
| 1719307330000 | 0 | None | None | Buildings | CONSTRUCTION OF AUDITORIUM, PROVIDING PROJECTOR 5, XEROX MACHINE-02, UPS WITH BATTERY, GENERATOR TO S.A.V.T. GOVT FIRST GRADE COLLEGE (Gen-6.12 LC) | 515452.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346227 | 117611 | None | GEM Rate | ahuja Two Way PA Speaker, Warranty 3 Years
ahujaR (ABA-4000 with extended warranty)
| Each | 23665.2 | 23665.2 | 10.0 | False | None | None | False | None | False | 236652.0 | 0 | 3346228 | 117611 | None | GEM Rate | acer Intel Core i5 10400 8 GB/ 1000 GB HDD/ DOS acerR (Veriton S2670G)
| Each | 69700.0 | 69700.0 | 4.0 | False | None | None | False | None | False | 278800.0 | 0 |
| 1719307330000 | 1 | None | None | Buildings | Provision for electrification, UPS with Battery, Generator, Speakers and Transformer | 1501306.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346229 | 117612 | None | Common DSR For 2023-24 Volume VI1.2.2PWD Elec SR | Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 81.9 | 81.9 | 160.0 | False | None | None | False | None | False | 13104.0 | 0 | 3346230 | 117612 | None | Common DSR For 2023-24 Volume VI1.3.2PWD Elec SR | Supplying heavy gauge PVC Conduit Pipe . dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick
| m | 82.95 | 82.95 | 120.0 | False | None | None | False | None | False | 9954.0 | 0 | 3346231 | 117612 | None | Common DSR For 2023-24 Volume VI1.4.4 Elec SR | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mm
| Each | 169.05 | 169.05 | 12.0 | False | None | None | False | None | False | 2028.6 | 0 | 3346232 | 117612 | None | Common DSR For 2023-24 Volume VI1.6.1 Elec SR | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" (300 x 300 x 76 mm)
| Each | 126.0 | 126.0 | 12.0 | False | None | None | False | None | False | 1512.0 | 0 | 3346233 | 117612 | None | Common DSR For 2023-24 Volume VI6.4.1PWD Elec SR | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)
| Each | 2810.85 | 2810.85 | 15.0 | False | None | None | False | None | False | 42162.75 | 0 | 3346234 | 117612 | None | Common DSR For 2023-24 Volume VI11.3.2PWD Elec S | Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuse r with Life of 25000 burning hours& 70% lumen maintenance with CR I 80. Power Input: 220-240 V@ 50/60 Hz &Power factor 0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' 20/22 w | Each | 724.5 | 724.5 | 25.0 | False | None | None | False | None | False | 18112.5 | 0 | 3346235 | 117612 | None | Common DSR For 2023-24 Volume VI2.1.2PWD Elec SR | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient lo Medium point above 3m upto 6m from tapping point to out let
via switch"
| Point | 299.24 | 299.24 | 15.0 | False | None | None | False | None | False | 4488.6 | 0 | 3346236 | 117612 | None | Common DSR For 2023-24 Volume VI2.1.2PWD Elec SR | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient lo Medium point above 3m upto 6m from tapping point to out let
via switch"
| Point | 413.7 | 413.7 | 15.0 | False | None | None | False | None | False | 6205.5 | 0 | 3346237 | 117612 | None | Common DSR For 2023-24 Volume VI2.1.3PWD Elec SR | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient lo Long point above 6m upto 10m from tapping point to out let via
switch"
| Point | 598.5 | 598.5 | 15.0 | False | None | None | False | None | False | 8977.5 | 0 | 3346238 | 117612 | None | Common DSR For 2023-24 Volume VI3.1.2PWD Elec SR | Supplying 6A flush type socket and 6 A flush type SP switch either surface/ flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way
| Point | 154.35 | 154.35 | 15.0 | False | None | None | False | None | False | 2315.25 | 0 | 3346239 | 117612 | None | Common DSR For 2023-24 Volume VI3.9PWD Elec SR 2 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.
| Sq CM | 0.37 | 0.37 | 4800.0 | False | None | None | False | None | False | 1776.0 | 0 | 3346240 | 117612 | None | Common DSR For 2023-24 Volume VI2.3.3PWD Elec SR | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2
| m | 44.1 | 44.1 | 230.0 | False | None | None | False | None | False | 10143.0 | 0 | 3346241 | 117612 | None | Common DSR For 2023-24 Volume VI5.18.4PWD Elec S | Supplying & fixing miniature circuitbreakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 6-32 A DP
| Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 | 3346242 | 117612 | None | Common DSR For 2023-24 Volume VI6.1PWD Elec SR 2 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| Each | 1566.6 | 1566.6 | 4.0 | False | None | None | False | None | False | 6266.4 | 0 | 3346243 | 117612 | None | Common DSR For 2023-24 Volume VI389ESCOM SR 2023 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg
| No | 780.15 | 780.15 | 8.0 | False | None | None | False | None | False | 6241.2 | 0 | 3346244 | 117612 | None | Common DSR For 2023-24 Volume VI390ESCOM SR 2023 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each
| No | 709.8 | 709.8 | 8.0 | False | None | None | False | None | False | 5678.4 | 0 | 3346245 | 117612 | None | Common DSR For 2023-24 Volume VI391ESCOM SR 2023 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag
| Bag | 325.5 | 325.5 | 8.0 | False | None | None | False | None | False | 2604.0 | 0 | 3346246 | 117612 | None | Common DSR For 2023-24 Volume VI11.11.6PWD Elec | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15W, 6500K
| Each | 342.3 | 342.3 | 18.0 | False | None | None | False | None | False | 6161.4 | 0 | 3346247 | 117612 | None | Common DSR For 2023-24 Volume VI6.8.2PWD Elec SR | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 3 star 1.5 Ton capacity
| Each | 47548.2 | 47548.2 | 2.0 | False | None | None | False | None | False | 95096.4 | 0 | 3346248 | 117612 | None | Common DSR For 2023-24 Volume VI11.6.2PWD Elec S | Supplying of recess mountingnon integral type.LEDw luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, Power LED swith CCT6500 degreeK, CRI70%. efficacy100 lumenper W,120 degree beam spread, life25000burning hours and Compliance to IS10322/IEC60598, LM79&L M80. The lamp compartment is enclosed with antiglare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF0.95, power losss hould 5% flamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than20%, Life as per LM79. The operating input voltage should be between 130to275V. BISApproved and Tested by NABL/CPRI accredited laboratory with 2years Warranty aga instany manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 24W
| Each | 3876.6 | 3876.6 | 25.0 | False | None | None | False | None | False | 96915.0 | 0 | 3346249 | 117612 | None | Electrical DSR 2014-15 I No15.108.1PWD Elec SR 2 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictor on Accomdated in M.S.Cabinet with painting including cost of materials, labour, usage charges of machinery complete as per specifications 10 Zone cansole.
| Each | 36750.0 | 36750.0 | 2.0 | False | None | None | False | None | False | 73500.0 | 0 | 3346250 | 117612 | None | Electrical DSR 2014-15 I No15.109PWD Elec SR 2 P | P.A. System amplifier 250WRMS output with complete wiring and controls accessable form front
| Each | 37012.5 | 37012.5 | 1.0 | False | None | None | False | None | False | 37012.5 | 0 | 3346251 | 117612 | None | Electrical DSR 2014-15 I No15.11PWD Elec SR 2 P. | Supplying Installing, testing and commissioning of MIKE suitable to I.A.System. Complete
| No | 5775.0 | 5775.0 | 4.0 | False | None | None | False | None | False | 23100.0 | 0 | 3346252 | 117612 | None | Electrical DSR 2014-15 I No15.11P .No.102 | Speaker Cables Supply, installation, testing and commissioning professional grade 2.5 sq mm
TIN coated low loss 2 core multi strand Oxidation Free speaker cable including, lead and lifts, loading and
unloading, cost of conveyance for all the materials with the accessories."
| m | 39.9 | 39.9 | 200.0 | False | None | None | False | None | False | 7980.0 | 0 | 3346253 | 117612 | None | Common DSR For 2023-24 Volume VI6.3.2PWD Elec SR | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model
| Each | 3182.55 | 3182.55 | 7.0 | False | None | None | False | None | False | 22277.85 | 0 | 3346254 | 117612 | None | Common DSR For 2023-24 Volume VI9.2.5PWD Elec SR | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries
and wiring complete. 5 kVA OFF LINE UPS"
| Each | 41892.9 | 41892.9 | 1.0 | False | None | None | False | None | False | 41892.9 | 0 | 3346255 | 117612 | None | Common DSR For 2023-24 Volume VI9.4.7PWD Elec SR | Supplying, installation, testing & commissioning of 12V .AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 200 AH capacity
| Each | 36436.05 | 36436.05 | 6.0 | False | None | None | False | None | False | 218616.3 | 0 | 3346256 | 117612 | None | Common DSR For 2023-24 Volume VI10.1.4PWD Elec S | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications.Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10percent for one hour in 12 hours of operation Capacity of Fuel Tank Fuel tank suitable for 8 hours of operation Alternator Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0percent Voltage regulation (max) in static conditions- IP 23 protections with insulation class F&H. Mounting arrangement Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for Load On and Set Running Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0- 600secs priorto shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working.Engine Protective functions include, Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure
| Set | 479920.35 | 479920.35 | 1.0 | False | None | None | False | None | False | 479920.35 | 0 | 3346257 | 117612 | None | Common DSR For 2023-24 Volume VI10.2.1PWD Elec S | Supply, Erection, testing and commissioning of AMF panel suitable for .kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure Timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301controller with water temperature / Lube oil pressure/ engine speed, Voltage / ampere / Frequency / kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery Charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms 15 KVA to 30 KVA
| Each | 61646.55 | 61646.55 | 1.0 | False | None | None | False | None | False | 61646.55 | 0 | 3346258 | 117612 | None | Common DSR For 2023-24 Volume VI203ESCOM SR 2023 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)
| Km | 146526.45 | 146526.45 | 0.05 | False | None | None | False | None | False | 7326.3225 | 0 | 3346259 | 117612 | None | Common DSR For 2023-24 Volume I 1.6.1P.No. 06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m
| Sqm | 508.2 | 508.2 | 18.75 | False | None | None | False | None | False | 9528.75 | 0 | 3346260 | 117612 | None | Common DSR For 2023-24 Volume VI140ESCOM SR 2023 | Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018)
| Set | 18442.2 | 18442.2 | 1.0 | False | None | None | False | None | False | 18442.2 | 0 | 3346261 | 117612 | None | Common DSR For 2023-24 Volume VI168ESCOM SR 2023 | 11 kV, 200 Amps Single Break GOS, Vertically Operated
| Set | 14413.35 | 14413.35 | 1.0 | False | None | None | False | None | False | 14413.35 | 0 | 3346262 | 117612 | None | Common DSR For 2023-24 Volume VI172ESCOM SR 2023 | H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI
| Set | 6374.55 | 6374.55 | 1.0 | False | None | None | False | None | False | 6374.55 | 0 | 3346263 | 117612 | None | Common DSR For 2023-24 Volume VI1ESCOM SR 2023-2 | RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/ QS&S /02 Dtd 24.11.2018) as per IS-785
| No | 7429.8 | 7429.8 | 2.0 | False | None | None | False | None | False | 14859.6 | 0 | 3346264 | 117612 | None | Common DSR For 2023-24 Volume VI11ESCOM SR 2023- | 11 kV, Horizontal Cross Arm - Mild Steel (MS)
(Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)
| No | 390.6 | 390.6 | 8.0 | False | None | None | False | None | False | 3124.8 | 0 | 3346265 | 117612 | None | Common DSR For 2023-24 Volume VI55ESCOM SR 2023- | DISC Insulator 45 kN Porcelain
| No | 535.5 | 535.5 | 6.0 | False | None | None | False | None | False | 3213.0 | 0 | 3346266 | 117612 | None | Common DSR For 2023-24 Volume VI176ESCOM SR 2023 | 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification
| Set | 6168.75 | 6168.75 | 1.0 | False | None | None | False | None | False | 6168.75 | 0 | 3346267 | 117612 | None | Common DSR For 2023-24 Volume VI137ESCOM SR 2023 | 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)
| No | 966.0 | 966.0 | 3.0 | False | None | None | False | None | False | 2898.0 | 0 | 3346268 | 117612 | None | Common DSR For 2023-24 Volume VI59ESCOM SR 2023- | Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
| Km | 48545.7 | 48545.7 | 0.15 | False | None | None | False | None | False | 7281.855 | 0 | 3346269 | 117612 | None | Common DSR For 2023-24 Volume VI133ESCOM SR 2023 | LT Protection Kit(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)
| No | 2124.15 | 2124.15 | 1.0 | False | None | None | False | None | False | 2124.15 | 0 | 3346270 | 117612 | None | CESR 2023-24 p.No-20 Item No.5.40.2 | Supplying . A rated 3phase with neutral bus bar using
required capacity electrolytic aluminium strips covered with heat
shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC
insulator which are mounted on powder coated 40x6mm M.S.flat
frame work in existing panel board. The bus bar shall have suitable
holes for termination of incoming and outgoing cables as per IS
specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips | Rmtr | 3606.75 | 3606.75 | 0.9 | False | None | None | False | None | False | 3246.075 | 0 | 3346271 | 117612 | None | CESR 23-24 P.No 20 Item No 5.42. | Fabricating supplying and mounting MS box made out .SWG
suitable for floor /wall mounting, fully weather proof with provision
for better heat dissipation, provided with hinged front cover,
equipped with tamper proof locking arrangements, with suitable
size clamps with necessary cable entry pipe with gland and box
should be finished with 7tanks treatment with powder coated paint
and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3346272 | 117612 | None | CESR 2023-24 P.No17 Item no 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the
existing wood/panel board using necessary screws, bolts, nuts,
necessary phase separators, handle and wiring complete. Protection of
Overload and Short circuitwith adjustable thermal magnetic release,
Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .
(Icu=100% lcs). In 4P MCCB, all Poles should have protection for
Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for
segregating Priority and Non-Priority loads must be available in the
MCCB. MCCB shall be provided with double insulation (insulation
between front cover and internal power circuits to avoid any accidental
contact with live current carrying path with the front cover open).
Multi-pole breakers shall be designed to break all the poles
simultaneously and they shall have a single mechanism. | Each | 24722.25 | 24722.25 | 1.0 | False | None | None | False | None | False | 24722.25 | 0 | 3346273 | 117612 | None | CESR 2023-24 P.No-19 Item No.5.38 | Supplying and fixing of LED type panel board indicating lamp
with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 | 3346274 | 117612 | None | CESR 2023-24 P.No-19 Item No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1496.25 | 1496.25 | 1.0 | False | None | None | False | None | False | 1496.25 | 0 | 3346275 | 117612 | None | CESR 2023-24 P.No-19 Item No-5.32 | Supplying and fixing digital frequency meter with latest micro
controller technology, ultra bright 4 digit LED display, from 30-500V
AC and optional or relay output for high/low frequency and wiring
complete. | Each | 971.25 | 971.25 | 1.0 | False | None | None | False | None | False | 971.25 | 0 | 3346276 | 117612 | None | CESR 2023-24 P.No-17 Item No-5.18.8 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. 40 A TPN | Each | 3196.2 | 3196.2 | 4.0 | False | None | None | False | None | False | 12784.8 | 0 | 3346277 | 117612 | None | CESR 2023-24 P.N.15 Item No.5.12.3 | Supplying of on load change over switches 4 poles, AC-23A
Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 A | Each | 10842.3 | 10842.3 | 1.0 | False | None | None | False | None | False | 10842.3 | 0 | 3346278 | 117612 | None | CESR 2023-24 VI P.N.57 Item No.13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 A | Nos | 330.75 | 330.75 | 15.0 | False | None | None | False | None | False | 4961.25 | 0 | 3346279 | 117612 | None | CESR 2023-24 VI P.N.57 Item No.13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Nos | 742.35 | 742.35 | 4.0 | False | None | None | False | None | False | 2969.4 | 0 | 3346280 | 117612 | None | CESR 2023-24 VI P.N.57 Item No.13.19 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.
| Nos | 514.5 | 514.5 | 25.0 | False | None | None | False | None | False | 12862.5 | 0 | 3346281 | 117612 | None | CESR 2023-24 VI P.N.47 Item No.11.13.2 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.
| Nos | 282.45 | 282.45 | 18.0 | False | None | None | False | None | False | 5084.1 | 0 | 3346282 | 117612 | None | CESR 2023-24 VI P.N.52 Item No.21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using
Wooden/Aluminum Rollers as directed by the departmental staff LT Cable | Km | 16966.95 | 16966.95 | 0.05 | False | None | None | False | None | False | 848.3475 | 0 |
| 1719307330000 | 0 | None | None | Buildings | WS & Sanitary | 127946.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346283 | 117613 | None | Common DSR For 2023-24 Volume I1.17.1P.No. 10 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m
| Cum | 275.1 | 275.1 | 30.94 | False | None | None | False | None | False | 8511.594 | 0 | 3346284 | 117613 | None | Common DSR For 2023-24 Volume V16.1.2 | Providing, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing. 150 mm dia. pipes
| m | 610.05 | 610.05 | 35.0 | False | None | None | False | None | False | 21351.75 | 0 | 3346285 | 117613 | None | Common DSR For 2023-24 Volume V16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| Each | 5726.7 | 5726.7 | 4.0 | False | None | None | False | None | False | 22906.8 | 0 | 3346286 | 117613 | None | CommonDSRFor 2023-24 Volume II13.31.4P.No. | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 32 mm nominal dia Pipes"
| m | 420.0 | 420.0 | 20.0 | False | None | None | False | None | False | 8400.0 | 0 | 3346287 | 117613 | None | Common DSR For 2023-24 Volume II13.31.3P.No. | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 25 mm nominal dia Pipes"
| m | 333.9 | 333.9 | 10.0 | False | None | None | False | None | False | 3339.0 | 0 | 3346288 | 117613 | None | Common DSR For 2023-24 Volume II13.31.1P.No. | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 15 mm nominal dia Pipes"
| m | 191.1 | 191.1 | 10.0 | False | None | None | False | None | False | 1911.0 | 0 | 3346289 | 117613 | None | Common DSR For 2023-24 Volume V10.1.6 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3
| m | 308.7 | 308.7 | 10.0 | False | None | None | False | None | False | 3087.0 | 0 | 3346290 | 117613 | None | Common DSR For 2023-24 Volume II14.3.1P.No. 1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern &C.P. flushbendwithfittings&C.I. brackets, 40mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
| Each | 6275.85 | 6275.85 | 2.0 | False | None | None | False | None | False | 12551.7 | 0 | 3346291 | 117613 | None | Common DSR For 2023-24 Volume II14.7.3P.No. 1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
| Each | 3009.3 | 3009.3 | 2.0 | False | None | None | False | None | False | 6018.6 | 0 | 3346292 | 117613 | None | Common DSR For 2023-24 Volume II14.8P.No. 133 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
| Each | 1494.15 | 1494.15 | 2.0 | False | None | None | False | None | False | 2988.3 | 0 | 3346293 | 117613 | None | Common DSR For 2023-24 Volume II14.32.1P.No. | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
| Each | 1142.4 | 1142.4 | 2.0 | False | None | None | False | None | False | 2284.8 | 0 | 3346294 | 117613 | None | Common DSR For 2023-24 Volume II14.40.2P.No. | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| Each | 520.8 | 520.8 | 2.0 | False | None | None | False | None | False | 1041.6 | 0 | 3346295 | 117613 | None | Common DSR For 2023-24 Volume II14.41P.No. 13 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g.
| Each | 527.1 | 527.1 | 2.0 | False | None | None | False | None | False | 1054.2 | 0 | 3346296 | 117613 | None | Common DSR For 2023-24 Volume II13.34P.No. 12 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
| l | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 | 3346297 | 117613 | None | Common DSR For 2023-24 Volume II13.36P.No. 12 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks
| Each | 339.15 | 339.15 | 0.92 | False | None | None | False | None | False | 312.018 | 0 | 3346298 | 117613 | None | Common DSR For 2023-24 Volume II13.2.2P.No. 1 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore
| No | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 | 3346299 | 117613 | None | Common DSR For 2023-24 Volume II13.3.2P.No. 1 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
| No | 320.25 | 320.25 | 2.0 | False | None | None | False | None | False | 640.5 | 0 | 3346300 | 117613 | None | Common DSR For 2023-24 Volume II13.4.2P.No. 1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
| No | 627.9 | 627.9 | 1.0 | False | None | None | False | None | False | 627.9 | 0 | 3346301 | 117613 | None | Common DSR For 2023-24 Volume II13.4.1P.No. 1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
| No | 576.45 | 576.45 | 1.0 | False | None | None | False | None | False | 576.45 | 0 | 3346302 | 117613 | None | Common DSR For 2023-24 Volume II13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5
| Each | 5924.1 | 5924.1 | 4.0 | False | None | None | False | None | False | 23696.4 | 0 |
| 1719307330000 | 0 | None | None | Buildings | ELECTRICAL (SCP Work code-VNR22411501259) | 199453.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3346303 | 117614 | None | CESR 2023-24 P.No-82 Item No-12.03 Vol-6 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 A. OPEN BUSHING TYPE 63 kVA, Aluminum Wdg, Star 1 (4 Star) | Nos | 173993.4 | 173993.4 | 1.0 | False | None | None | False | None | False | 173993.4 | 0 | 3346304 | 117614 | None | Common DSR For 2023-24 Volume VI6.3.2PWD Elec SR | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model | Nos | 3182.55 | 3182.55 | 8.0 | False | None | None | False | None | False | 25460.4 | 0 |
|
|
---|