| 3449799 | 122649 | None | 001 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 11271.0 | 11271.0 | 58.0 | False | None | None | False | None | False | 653718.0 | 0 |
| 3449800 | 122649 | None | 002 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintels (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 10608.0 | 10608.0 | 27.0 | False | None | None | False | None | False | 286416.0 | 0 |
| 3449801 | 122649 | None | 003 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chajja (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 9613.5 | 9613.5 | 10.0 | False | None | None | False | None | False | 96135.0 | 0 |
| 3449802 | 122649 | None | 004 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Staircase waist Slab (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 9945.0 | 9945.0 | 8.0 | False | None | None | False | None | False | 79560.0 | 0 |
| 3449803 | 122649 | None | 005 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam (Vol 1, Pg.no.16, Item no. 2.5.2)
| Cum | 10608.0 | 10608.0 | 73.56 | False | None | None | False | None | False | 780324.48 | 0 |
| 3449804 | 122649 | None | 006 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab (Vol 1, Pg.no.16, Item no. 2.5.3)
| Cum | 9945.0 | 9945.0 | 244.06 | False | None | None | False | None | False | 2427176.7 | 0 |
| 3449805 | 122649 | None | 007 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in Superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol 2, Pg.no.14, Item no. 6.8)
| Cum | 7969.0 | 7969.0 | 400.0 | False | None | None | False | None | False | 3187600.0 | 0 |
| 3449806 | 122649 | None | 008 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a))
| Tonne | 89457.0 | 89457.0 | 76.0 | False | None | None | False | None | False | 6798732.0 | 0 |
| 3449807 | 122649 | None | 009 | Providing and fixing in position Mathi/Nandi wood half panelled shutters at bottom and half glazed at top for window shutters with stiles and rails of 35mm thick, 75mm wide in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (Vol 2, Pg.no.102, Item no. 12.37)
| Sqm | 6456.0 | 6456.0 | 58.65 | False | None | None | False | None | False | 378644.4 | 0 |
| 3449808 | 122649 | None | 010 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Vol 2, Pg.no.99, Item no. 12.11)
| Cum | 138074.0 | 138074.0 | 2.06 | False | None | None | False | None | False | 284432.44 | 0 |
| 3449809 | 122649 | None | 011 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam (Vol 2, Pg.no.104, Item no. 12.55.1)
| Sqm | 2366.0 | 2366.0 | 24.36 | False | None | None | False | None | False | 57635.76 | 0 |
| 3449810 | 122649 | None | 012 | Providing and fixing of bright finished brass quality fixtures to the doors such as aldrop, handle, latches tower bolt etc… including labour charges complete as per the direction of the Engineer in charge (MR)
| Each | 3000.0 | 3000.0 | 30.0 | False | None | None | False | None | False | 90000.0 | 0 |
| 3449811 | 122649 | None | 013 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Vol 2, Pg.no.86, Item no. 11.34A)
| Kg | 168.0 | 168.0 | 2800.0 | False | None | None | False | None | False | 470400.0 | 0 |
| 3449812 | 122649 | None | 014 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. (MR)
| Sqm | 5700.0 | 5700.0 | 66.0 | False | None | None | False | None | False | 376200.0 | 0 |
| 3449813 | 122649 | None | 015 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineering-charge. (Vol 2, Pg.no.42, Item no. 8.6.1)
| Sqm | 323.0 | 323.0 | 4600.0 | False | None | None | False | None | False | 1485800.0 | 0 |
| 3449814 | 122649 | None | 016 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.42, Item no. 8.9)
| Sqm | 385.0 | 385.0 | 3070.0 | False | None | None | False | None | False | 1181950.0 | 0 |
| 3449815 | 122649 | None | 017 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, Including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (Vol 2, Pg.no.62, Item no. 9.21.2)
| Sqm | 1447.0 | 1447.0 | 1985.35 | False | None | None | False | None | False | 2872801.45 | 0 |
| 3449816 | 122649 | None | 018 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (Vol 2, Pg.no.60, Item no. 9.10)
| Sqm | 1106.0 | 1106.0 | 225.0 | False | None | None | False | None | False | 248850.0 | 0 |
| 3449817 | 122649 | None | 019 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.51)
| Sqm | 100.0 | 100.0 | 4400.0 | False | None | None | False | None | False | 440000.0 | 0 |
| 3449818 | 122649 | None | 020 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.51, Item no. 8.55.2)
| Sqm | 53.0 | 53.0 | 4400.0 | False | None | None | False | None | False | 233200.0 | 0 |
| 3449819 | 122649 | None | 021 | Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic ompound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.54.2)
| Sqm | 110.0 | 110.0 | 4400.0 | False | None | None | False | None | False | 484000.0 | 0 |
| 3449820 | 122649 | None | 022 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.45, Item no. 8.27)
| Sqm | 53.0 | 53.0 | 2690.0 | False | None | None | False | None | False | 142570.0 | 0 |
| 3449821 | 122649 | None | 023 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.53, Item no. 8.75.1)
| Sqm | 111.0 | 111.0 | 4950.0 | False | None | None | False | None | False | 549450.0 | 0 |
| 3449822 | 122649 | None | 024 | KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)
| Sqm | 4741.4 | 4741.4 | 165.15 | False | None | None | False | None | False | 783042.21 | 0 |
| 3449823 | 122649 | None | 025 | KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions using sections in combination of plain, single grove and double grove as per requirements for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683 kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet both side of approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistling and making good with cement mortar to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable size holes and fixing with cement mortar, with necessary opening for fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)
| Sqm | 5082.7 | 5082.7 | 5.04 | False | None | None | False | None | False | 25616.808 | 0 |
| 3449824 | 122649 | None | 026 | KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)
| Sqm | 6593.2 | 6593.2 | 3.78 | False | None | None | False | None | False | 24922.296 | 0 |
| 3449825 | 122649 | None | 027 | KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)
| Sqm | 4637.5 | 4637.5 | 4.32 | False | None | None | False | None | False | 20034.0 | 0 |
| 3449826 | 122649 | None | 028 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (Vol 2, Pg.no.63, Item no. 9.28)
| Sqm | 4279.0 | 4279.0 | 230.0 | False | None | None | False | None | False | 984170.0 | 0 |
| 3449827 | 122649 | None | 029 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cement (Vol 2, Pg.no.59, Item no. 9.6.1)
| Sqm | 1269.0 | 1269.0 | 75.0 | False | None | None | False | None | False | 95175.0 | 0 |
| 3449828 | 122649 | None | 030 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.47, Item no. 8.33.3)
| Sqm | 139.0 | 139.0 | 330.0 | False | None | None | False | None | False | 45870.0 | 0 |
| 3449829 | 122649 | None | 031 | French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.49, Item no. 8.46)
| Sqm | 295.0 | 295.0 | 152.49 | False | None | None | False | None | False | 44984.55 | 0 |
| 3449830 | 122649 | None | 032 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Coping (Vol 1, Pg.no.15, Item no. 2.1.3)
| Cum | 6630.0 | 6630.0 | 5.0 | False | None | None | False | None | False | 33150.0 | 0 |
| 3449831 | 122649 | None | 033 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 15912.0 | 15912.0 | 2.0 | False | None | None | False | None | False | 31824.0 | 0 |
| 3449832 | 122649 | None | 034 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 14586.0 | 14586.0 | 15.0 | False | None | None | False | None | False | 218790.0 | 0 |
| 3449833 | 122649 | None | 035 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)
| Cum | 13260.0 | 13260.0 | 22.5 | False | None | None | False | None | False | 298350.0 | 0 |
| 3449834 | 122649 | None | 036 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a)
| Tonne | 89457.0 | 89457.0 | 4.0 | False | None | None | False | None | False | 357828.0 | 0 |
| 3449835 | 122649 | None | 037 | KSRB 10-3: Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kgl sqm of cement admixed with proprietary water proofing compound conforming to 18:2645 over the RCC slab after cleaning the before treatment. (b) Laying cement concrete using broken brick bats 25mm to 1OOmm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound 18:2645 20mm thick layer of cement 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300mm height including off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement of mix 1:4 admixed with water proofing compound and finally finishing the surface with trowel and neat cement and making of 300x300mm square. (e) the whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test including cost of materials complete as per specifications (MR)
| Sqm | 1102.2 | 1102.2 | 2000.0 | False | None | None | False | None | False | 2204400.0 | 0 |
| 3449836 | 122649 | None | 038 | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 (Vol 2, Pg.no.126, Item no. 13.54)
| Each | 6278.0 | 6278.0 | 4.0 | False | None | None | False | None | False | 25112.0 | 0 |
| 3449837 | 122649 | None | 039 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 lt low level white P.V.C. flushing including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Vol 2, Pg.no.131, Item no. 14.11)
| Each | 4884.0 | 4884.0 | 6.0 | False | None | None | False | None | False | 29304.0 | 0 |
| 3449838 | 122649 | None | 040 | Providing and fixing white vitreous china pedestal type water closet European type with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend,overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (Vol 2, Pg.no.131, Item no. 14.2.1)
| Each | 4838.0 | 4838.0 | 4.0 | False | None | None | False | None | False | 19352.0 | 0 |
| 3449839 | 122649 | None | 041 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (Vol 2, Pg.no.132, Item no. 14.7.1)
| Each | 3082.0 | 3082.0 | 10.0 | False | None | None | False | None | False | 30820.0 | 0 |
| 3449840 | 122649 | None | 042 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 g (Vol 2, Pg.no.137, Item no. 14.39)
| Each | 195.0 | 195.0 | 4.0 | False | None | None | False | None | False | 780.0 | 0 |
| 3449841 | 122649 | None | 043 | Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 25 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.1)
| Nos | 549.0 | 549.0 | 10.0 | False | None | None | False | None | False | 5490.0 | 0 |
| 3449842 | 122649 | None | 044 | Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 32 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.2)
| Nos | 598.0 | 598.0 | 10.0 | False | None | None | False | None | False | 5980.0 | 0 |
| 3449843 | 122649 | None | 045 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.3.2)
| Nos | 305.0 | 305.0 | 20.0 | False | None | None | False | None | False | 6100.0 | 0 |
| 3449844 | 122649 | None | 046 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.2.1)
| Nos | 286.0 | 286.0 | 10.0 | False | None | None | False | None | False | 2860.0 | 0 |
| 3449845 | 122649 | None | 047 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 g (Vol 2, Pg.no.120, Item no. 13.20.2)
| Nos | 314.0 | 314.0 | 10.0 | False | None | None | False | None | False | 3140.0 | 0 |
| 3449846 | 122649 | None | 048 | Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia (Vol 2, Pg.no.120, Item no. 13.22.1.1)
| Nos | 41.0 | 41.0 | 12.0 | False | None | None | False | None | False | 492.0 | 0 |
| 3449847 | 122649 | None | 049 | Providing and fixing 100 mm sand cast iron grating for gully trap (Vol 2, Pg.no.136, Item no. 14.29)
| Each | 47.0 | 47.0 | 12.0 | False | None | None | False | None | False | 564.0 | 0 |
| 3449848 | 122649 | None | 050 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 25mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.114, Item no. 10.1.1)
| m | 48.0 | 48.0 | 150.0 | False | None | None | False | None | False | 7200.0 | 0 |
| 3449849 | 122649 | None | 051 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 32mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.113, Item no. 10.1.2)
| m | 67.0 | 67.0 | 50.0 | False | None | None | False | None | False | 3350.0 | 0 |
| 3449850 | 122649 | None | 052 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia. (Vol 5, Pg.no.114, Item no. 10.2.1)
| m | 217.0 | 217.0 | 40.0 | False | None | None | False | None | False | 8680.0 | 0 |
| 3449851 | 122649 | None | 053 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia. (Vol 5, Pg.no.114, Item no. 10.2.2)
| m | 288.0 | 288.0 | 50.0 | False | None | None | False | None | False | 14400.0 | 0 |
| 3449852 | 122649 | None | 054 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.6)
| Each | 245.0 | 245.0 | 20.0 | False | None | None | False | None | False | 4900.0 | 0 |
| 3449853 | 122649 | None | 055 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.8)
| Each | 492.0 | 492.0 | 20.0 | False | None | None | False | None | False | 9840.0 | 0 |
| 3449854 | 122649 | None | 056 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp (Vol 2, Pg.no.176, Item no. 17.10.1)
| Kg | 1777.0 | 1777.0 | 5.0 | False | None | None | False | None | False | 8885.0 | 0 |
| 3449855 | 122649 | None | 057 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Vol 2, Pg.no.123, Item no. 13.34)
| l | 9.0 | 9.0 | 4000.0 | False | None | None | False | None | False | 36000.0 | 0 |
| 3449856 | 122649 | None | 058 | KSRB 8.6-1 : Providing and fixing on wall surface 2.5 kg/sq.cm H.D.P.E. rain down water pipes of approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of labour, complete as per specifications. 2.5 kg/sq.cm H.D.P.E. rain down water pipes 90 mm outer d (MR)
| m | 401.5 | 401.5 | 100.0 | False | None | None | False | None | False | 40150.0 | 0 |
| 3449857 | 122649 | None | 059 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Vol 2, Pg.no.187, Item no. 19.3)
| Cum | 2426.0 | 2426.0 | 11.81 | False | None | None | False | None | False | 28651.06 | 0 |
| 3449858 | 122649 | None | 060 | Providing and fixing of GI sheet with tubuluar steel structure with the self driven screws, bolts including nuts and washers complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (MR)
| Kg | 125.0 | 125.0 | 445.0 | False | None | None | False | None | False | 55625.0 | 0 |
| 3449859 | 122649 | None | 061 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Vol 2, Pg.no.26, Item no. 7.38)
| Sqm | 568.0 | 568.0 | 240.0 | False | None | None | False | None | False | 136320.0 | 0 |
| 3449860 | 122649 | None | 111 | Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm
thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws." 19/20mm dia 2mm thick
| Mtr | 69.0 | 69.0 | 50.0 | False | None | None | False | None | False | 3450.0 | 0 |
| 3449861 | 122649 | None | 112 | Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm
thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws."25mm dia 2mm thick
| Mtr | 81.0 | 81.0 | 50.0 | False | None | None | False | None | False | 4050.0 | 0 |
| 3449862 | 122649 | None | 113 | Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm
thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32mm dia 2.5mm thick
| Mtr | 106.0 | 106.0 | 15.0 | False | None | None | False | None | False | 1590.0 | 0 |
| 3449863 | 122649 | None | 121 | Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia .
mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"19/20mm dia 2mm thick
| Mtr | 66.0 | 66.0 | 950.0 | False | None | None | False | None | False | 62700.0 | 0 |
| 3449864 | 122649 | None | 122 | Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia .
mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"25mm dia 2mm thick
| Mtr | 78.0 | 78.0 | 450.0 | False | None | None | False | None | False | 35100.0 | 0 |
| 3449865 | 122649 | None | 123 | upplying heavy gauge PVC conduit pipe ……mm dia .
mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary32mm dia 2.5mm thick
| Mtr | 103.0 | 103.0 | 50.0 | False | None | None | False | None | False | 5150.0 | 0 |
| 3449866 | 122649 | None | 131 | Supplying heavy gauge PVC Conduit Pipe ….dia mm
thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary."
19/20mm dia 2mm thick
| Mtr | 68.0 | 68.0 | 185.0 | False | None | None | False | None | False | 12580.0 | 0 |
| 3449867 | 122649 | None | 132 | Supplying heavy gauge PVC Conduit Pipe ….dia mm
thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary."
25mm dia 2mm thick
| Mtr | 79.0 | 79.0 | 50.0 | False | None | None | False | None | False | 3950.0 | 0 |
| 3449868 | 122649 | None | 133 | Supplying heavy gauge PVC Conduit Pipe ….dia mm
thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary."
32mm dia 2.5mm thick
| Mtr | 99.0 | 99.0 | 15.0 | False | None | None | False | None | False | 1485.0 | 0 |
| 3449869 | 122649 | None | 151 | Supplying and fixing PVC/Metal conduit
accessories."Deep junction boxes"Supplying and
fixing PVC/metal conduitDeep Junction Box. P-2"
a) 19/20 mm deep junction boxes
| Each | 49.0 | 49.0 | 185.0 | False | None | None | False | None | False | 9065.0 | 0 |
| 3449870 | 122649 | None | 152 | Supplying and fixing PVC/Metal conduit
accessories."Deep junction boxes"Supplying and
fixing PVC/metal conduitDeep Junction Box. P-2"b) 25 mm deep junction boxes
| Each | 56.0 | 56.0 | 75.0 | False | None | None | False | None | False | 4200.0 | 0 |
| 3449871 | 122649 | None | 153 | Supplying and fixing PVC/Metal conduit
accessories. | Each | 61.0 | 61.0 | 15.0 | False | None | None | False | None | False | 915.0 | 0 |
| 3449872 | 122649 | None | 171 | Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3a) Upto 50 mm conduit in brick wall
| Mtr | 29.0 | 29.0 | 150.0 | False | None | None | False | None | False | 4350.0 | 0 |
| 3449873 | 122649 | None | 172 | Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3b) Upto 50 mm conduit in CC floor
| Mtr | 69.0 | 69.0 | 15.0 | False | None | None | False | None | False | 1035.0 | 0 |
| 3449874 | 122649 | None | 181 | Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3a)20 mm dia
| Mtr | 28.0 | 28.0 | 150.0 | False | None | None | False | None | False | 4200.0 | 0 |
| 3449875 | 122649 | None | 182 | Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3b)25 mm dia
| Mtr | 35.0 | 35.0 | 15.0 | False | None | None | False | None | False | 525.0 | 0 |
| 3449876 | 122649 | None | 191 | Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3a)20 mm dia
| Mtr | 19.0 | 19.0 | 45.0 | False | None | None | False | None | False | 855.0 | 0 |
| 3449877 | 122649 | None | 192 | Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3b)25 mm dia
| Mtr | 22.0 | 22.0 | 25.0 | False | None | None | False | None | False | 550.0 | 0 |
| 3449878 | 122649 | None | 193 | Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3c)32 mm dia
| Mtr | 29.0 | 29.0 | 10.0 | False | None | None | False | None | False | 290.0 | 0 |
| 3449879 | 122649 | None | 110 | Supplying and fixing of ""S"" hook made out
of 14 mm dia M.S. Rod. P-3
| Each | 52.0 | 52.0 | 66.0 | False | None | None | False | None | False | 3432.0 | 0 |
| 3449880 | 122649 | None | 111 | Supplying and fixing M.S. rafter clamp made out of M.S. flat & 14 mm M.S. rod. P- 3
| Each | 160.0 | 160.0 | 66.0 | False | None | None | False | None | False | 10560.0 | 0 |
| 3449881 | 122649 | None | 112 | Supplying and fixing metal fan box with
round hook. P-3
| Each | 117.0 | 117.0 | 66.0 | False | None | None | False | None | False | 7722.0 | 0 |
| 3449882 | 122649 | None | 211 | Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet."a) Short point upto 3 Mtr from tapping
point to out let via switch.""a) Short point upto 3 Mtr from tapping
point to out let via switch."
| Point | 285.0 | 285.0 | 34.0 | False | None | None | False | None | False | 9690.0 | 0 |
| 3449883 | 122649 | None | 212 |
Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch
b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch
| Point | 394.0 | 394.0 | 50.0 | False | None | None | False | None | False | 19700.0 | 0 |
| 3449884 | 122649 | None | 213 | Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch.
| Point | 570.0 | 570.0 | 75.0 | False | None | None | False | None | False | 42750.0 | 0 |
| 3449885 | 122649 | None | 214 |
Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
"d)Two outlet in a row ,above 3 Mtrs. Upto
6 Mtrs. From tapping point to outlet via switches."
| Point | 708.0 | 708.0 | 34.0 | False | None | None | False | None | False | 24072.0 | 0 |
| 3449886 | 122649 | None | 215 |
Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
e)Three outlet in a row,above 6 Mtrs. Up to 10 Mtrs. From tapping point to out let via switches.
| Point | 1035.0 | 1035.0 | 35.0 | False | None | None | False | None | False | 36225.0 | 0 |
| 3449887 | 122649 | None | 221 | Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a "a) Short point upto 3 Mtr from tapping
point to out let via switch."
| Point | 269.0 | 269.0 | 34.0 | False | None | None | False | None | False | 9146.0 | 0 |
| 3449888 | 122649 | None | 222 | Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch
| Point | 379.0 | 379.0 | 50.0 | False | None | None | False | None | False | 18950.0 | 0 |
| 3449889 | 122649 | None | 223 | Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch.
| Point | 555.0 | 555.0 | 75.0 | False | None | None | False | None | False | 41625.0 | 0 |
| 3449890 | 122649 | None | 224 | Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a d) Two out let in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches.
| Point | 677.0 | 677.0 | 34.0 | False | None | None | False | None | False | 23018.0 | 0 |
| 3449891 | 122649 | None | 225 | Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a e) Three out let in a row, above 6 Mtrs upto 10 Mtrs from tapping point to out let via switches.
| Point | 989.0 | 989.0 | 35.0 | False | None | None | False | None | False | 34615.0 | 0 |
| 3449892 | 122649 | None | 231 | Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.0 Sqmm
| Mtr | 19.0 | 19.0 | 1800.0 | False | None | None | False | None | False | 34200.0 | 0 |
| 3449893 | 122649 | None | 232 | Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.5 Sqmm
| Mtr | 26.0 | 26.0 | 2880.0 | False | None | None | False | None | False | 74880.0 | 0 |
| 3449894 | 122649 | None | 233 | Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6
2.5 Sqmm
| Mtr | 42.0 | 42.0 | 2880.0 | False | None | None | False | None | False | 120960.0 | 0 |
| 3449895 | 122649 | None | 234 | Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6
4 Sqmm
| Mtr | 63.0 | 63.0 | 540.0 | False | None | None | False | None | False | 34020.0 | 0 |
| 3449896 | 122649 | None | 331 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 1-2 way
| Each | 103.0 | 103.0 | 17.0 | False | None | None | False | None | False | 1751.0 | 0 |
| 3449897 | 122649 | None | 332 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.
3 way | Each | 124.0 | 124.0 | 5.0 | False | None | None | False | None | False | 620.0 | 0 |
| 3449898 | 122649 | None | 334 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 6 way
| Each | 173.0 | 173.0 | 4.0 | False | None | None | False | None | False | 692.0 | 0 |
| 3449899 | 122649 | None | 335 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.
8way | Each | 219.0 | 219.0 | 10.0 | False | None | None | False | None | False | 2190.0 | 0 |
| 3449900 | 122649 | None | 336 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.
10 way | Each | 261.0 | 261.0 | 25.0 | False | None | None | False | None | False | 6525.0 | 0 |
| 3449901 | 122649 | None | 338 | Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.
18 way | Each | 339.0 | 339.0 | 15.0 | False | None | None | False | None | False | 5085.0 | 0 |
| 3449902 | 122649 | None | 341 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 1-2 way
| Each | 138.0 | 138.0 | 17.0 | False | None | None | False | None | False | 2346.0 | 0 |
| 3449903 | 122649 | None | 342 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall
3 way
| Each | 159.0 | 159.0 | 5.0 | False | None | None | False | None | False | 795.0 | 0 |
| 3449904 | 122649 | None | 351 | Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.a) 1 to 2 Module
| Each | 137.0 | 137.0 | 17.0 | False | None | None | False | None | False | 2329.0 | 0 |
| 3449905 | 122649 | None | 353 | Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.b) 4 Module
| Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
| 3449906 | 122649 | None | 354 | Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box. 8 module
| Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 |
| 3449907 | 122649 | None | 355 | Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.e)10-12 Module
| Each | 344.0 | 344.0 | 10.0 | False | None | None | False | None | False | 3440.0 | 0 |
| 3449908 | 122649 | None | 358 | Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.f)16-18 Module
| Each | 457.0 | 457.0 | 25.0 | False | None | None | False | None | False | 11425.0 | 0 |
| 3449909 | 122649 | None | 361 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.
a) 6 Amps one way.
| Each | 102.0 | 102.0 | 300.0 | False | None | None | False | None | False | 30600.0 | 0 |
| 3449910 | 122649 | None | 362 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.
b) 6 A amps Two way switch.
| Each | 166.0 | 166.0 | 4.0 | False | None | None | False | None | False | 664.0 | 0 |
| 3449911 | 122649 | None | 363 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.c) 6 Amps 5 way Socket
| Each | 171.0 | 171.0 | 55.0 | False | None | None | False | None | False | 9405.0 | 0 |
| 3449912 | 122649 | None | 364 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.d) Stepped Fan Regulator.
| Each | 357.0 | 357.0 | 60.0 | False | None | None | False | None | False | 21420.0 | 0 |
| 3449913 | 122649 | None | 368 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.g)16 Amps one way switch.
| Each | 180.0 | 180.0 | 20.0 | False | None | None | False | None | False | 3600.0 | 0 |
| 3449914 | 122649 | None | 3611 | Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.
j)6/16 Amps Universal socket.
| Each | 236.0 | 236.0 | 20.0 | False | None | None | False | None | False | 4720.0 | 0 |
| 3449915 | 122649 | None | 370 | Supplying & Fixing 32 Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & Competely wired on exixting box.
| Each | 646.0 | 646.0 | 4.0 | False | None | None | False | None | False | 2584.0 | 0 |
| 3449916 | 122649 | None | 310 | Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws.
a)80 mm dia
| Each | 15.0 | 15.0 | 300.0 | False | None | None | False | None | False | 4500.0 | 0 |
| 3449917 | 122649 | None | 3103 | Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws.
b)110 mm dia
| Each | 21.0 | 21.0 | 50.0 | False | None | None | False | None | False | 1050.0 | 0 |
| 3449918 | 122649 | None | 311 | Supplying and fixing of 50 mm wooden plug,tapered from 50x50 mm to 25x25mm and fixing by using binding wire before concreting a roof slab.
| Each | 12.0 | 12.0 | 200.0 | False | None | None | False | None | False | 2400.0 | 0 |
| 3449919 | 122649 | None | 3121 | Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws.
a) 1 way gang box
| Each | 23.0 | 23.0 | 10.0 | False | None | None | False | None | False | 230.0 | 0 |
| 3449920 | 122649 | None | 3122 | Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws.
b) 2 to 4 way gang box
| Each | 32.0 | 32.0 | 10.0 | False | None | None | False | None | False | 320.0 | 0 |
| 3449921 | 122649 | None | 3123 | Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws.
c) 6 to 10 way gang box
| Each | 53.0 | 53.0 | 10.0 | False | None | None | False | None | False | 530.0 | 0 |
| 3449922 | 122649 | None | 3164 | Supplying & Fixing PBBC/Bakelite Straight or Slant batten holder wiring,with in 6Amp 230 V lamps.
| Each | 71.0 | 71.0 | 300.0 | False | None | None | False | None | False | 21300.0 | 0 |
| 3449923 | 122649 | None | 1132 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition."
1x4'-22 Watts
| Each | 690.0 | 690.0 | 200.0 | False | None | None | False | None | False | 138000.0 | 0 |
| 3449924 | 122649 | None | 1163 | Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA
LED modular down light 2'x2' /1'x4'42-55 W | Each | 4553.0 | 4553.0 | 2.0 | False | None | None | False | None | False | 9106.0 | 0 |
| 3449925 | 122649 | None | 1182 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering
superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%
2 Years against any manufacturing defect LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 120 Watt | Each | 4024.0 | 4024.0 | 6.0 | False | None | None | False | None | False | 24144.0 | 0 |
| 3449926 | 122649 | None | 5181 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required.
6-32 Amps SP
| Each | 415.0 | 415.0 | 25.0 | False | None | None | False | None | False | 10375.0 | 0 |
| 3449927 | 122649 | None | 5182 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required.
40 Amps SP
| Each | 793.0 | 793.0 | 5.0 | False | None | None | False | None | False | 3965.0 | 0 |
| 3449928 | 122649 | None | 5184 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required.
6-32 Amps DP
| Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 |
| 3449929 | 122649 | None | 5185 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required.
40 Amps DP
| Each | 1060.0 | 1060.0 | 2.0 | False | None | None | False | None | False | 2120.0 | 0 |
| 3449930 | 122649 | None | 5187 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 AmpsTPN
| Each | 1717.0 | 1717.0 | 2.0 | False | None | None | False | None | False | 3434.0 | 0 |
| 3449931 | 122649 | None | 5189 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required.
40-63 Amps TPN
| Each | 3044.0 | 3044.0 | 2.0 | False | None | None | False | None | False | 6088.0 | 0 |
| 3449932 | 122649 | None | 51913 | Supplying and fixing regular MCB distribution boards on wall/ wood board/flush mounting using required clamps/bolts/nuts.,with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc.Made out of 14 SWG MS enclosure.Double Door
12 way TP &N
| Each | 8735.0 | 8735.0 | 6.0 | False | None | None | False | None | False | 52410.0 | 0 |
| 3449933 | 122649 | None | 5124 | Supplying of on load change over switches
4 pole, AC-23A Duty, 415 V, 50 Hz, AC Supply a) 200 Amps"
| Each | 15249.0 | 15249.0 | 1.0 | False | None | None | False | None | False | 15249.0 | 0 |
| 3449934 | 122649 | None | 5146 | Supplying and fixing of 4 pole power contactor with NO/NC contacts on exsiting panel board using necessary bolts and complete wiring with AC-3 rating and as per IS-13947, (100-125 Amps)
| Each | 16606.0 | 16606.0 | 1.0 | False | None | None | False | None | False | 16606.0 | 0 |
| 3449935 | 122649 | None | 51510 | Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole
a) 125-160 Amps 25ka
| Each | 10341.0 | 10341.0 | 1.0 | False | None | None | False | None | False | 10341.0 | 0 |
| 3449936 | 122649 | None | 51212 | Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole
| Each | 17301.0 | 17301.0 | 1.0 | False | None | None | False | None | False | 17301.0 | 0 |
| 3449937 | 122649 | None | 533 | Supplying of multi function digital meter with three line back light LCD type displayy for voltage, Current, Ferquency, power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completetly wired as required with communication port and class 0.5s accuracy
| Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
| 3449938 | 122649 | None | 053 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden CT. Class 0.5 accuracy with tape wound
| Each | 526.0 | 526.0 | 3.0 | False | None | None | False | None | False | 1578.0 | 0 |
| 3449939 | 122649 | None | 054 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC 50HZ 12/24V DC
| Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
| 3449940 | 122649 | None | 5401 | Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete.a)100Amps 4X30X6mm Aluminum strips
| Mtr | 2465.0 | 2465.0 | 10.0 | False | None | None | False | None | False | 24650.0 | 0 |
| 3449941 | 122649 | None | 5402 | Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete.
b)250 Amps 4X30X10mm Aluminum strips
| Mtr | 3435.0 | 3435.0 | 8.0 | False | None | None | False | None | False | 27480.0 | 0 |
| 3449942 | 122649 | None | 5421 | Fabricating Supplying and mounting MS box made out. SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equppied with tamper proof loacking arrangment, with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. (16SWG)
| Sq CM | 0.43 | 0.43 | 75000.0 | False | None | None | False | None | False | 32250.0 | 0 |
| 3449943 | 122649 | None | 061 | Supplying,fixing, wiring, earth electrode for grounding conduits, I.C. cutouts & other equipments on the meter board using 40mm dia 2.90 thick G.I. pipe 2.5m long buried in a pit. The pit should be filled with equal proprotion of salt & charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc. is to be established through G.I.wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers & checknuts etc, the pipe shall have 16 through holes of 12mm dia. SR 2018-19
| Each | 2999.7 | 2999.7 | 2.0 | False | None | None | False | None | False | 5999.4 | 0 |
| 3449944 | 122649 | None | 063 | Supplying & running of G.I/Cu strips for grounding connections, using necessary fixing materials as required.SR 2018-19
I) G.I Strip
a) 25 X 3 mm
| Mtr | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 |
| 3449945 | 122649 | None | 615 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only)25 mm dia
| Each | 84.0 | 84.0 | 4.0 | False | None | None | False | None | False | 336.0 | 0 |
| 3449946 | 122649 | None | 6152 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only)
50mm dia
| Each | 1785.0 | 1785.0 | 2.0 | False | None | None | False | None | False | 3570.0 | 0 |
| 3449947 | 122649 | None | 617 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.SR 2018-19
50 sqmm Long barrel
| Each | 60.0 | 60.0 | 10.0 | False | None | None | False | None | False | 600.0 | 0 |
| 3449948 | 122649 | None | 061 | Supplying exhaust fan Of 1440 RPM of 300mm size with bracket blades suitable for operate on 230V 50Hz. AC supply complete.
| Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 |
| 3449949 | 122649 | None | 631 | Supplying Capacitor type Ceiling Fan complete with down rod blades, shackle, canopies etc., for operation on 230Volts,50 cycles. Single ohase AC Supply conforming to ISS-374-1979 and with double ball bearing system.
Regular Model (48" Sweep)
| Each | 2984.0 | 2984.0 | 60.0 | False | None | None | False | None | False | 179040.0 | 0 |
| 3449950 | 122649 | None | 344 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall
6 way | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 |
| 3449951 | 122649 | None | 345 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall
8 way | Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 |
| 3449952 | 122649 | None | 346 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall
10 way | Each | 319.0 | 319.0 | 25.0 | False | None | None | False | None | False | 7975.0 | 0 |
| 3449953 | 122649 | None | 348 | Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall
18 way | Each | 405.0 | 405.0 | 15.0 | False | None | None | False | None | False | 6075.0 | 0 |
| 3449954 | 122649 | None | 615 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only) 50mm dia
| Each | 255.0 | 255.0 | 2.0 | False | None | None | False | None | False | 510.0 | 0 |