createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720079178241
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd554000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-08-2024 16:25:00
tenderQueryClose05-08-2024 16:20:00
technicalBidOpen09-08-2024 16:30:00
publishedDate04-07-2024 16:13:03
publishedByPostKSW_REG_UNC_VJP
publishedByUserKPE16213 - SHANKARGOUD S SOMANAL
bidValidityPeriod90
noOfCalls1
preBidMeetingDate01-08-2024 11:11:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonResident Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber0835229706
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1720079178267
version8
createdDateNone
modifiedDateNone
tenderNumberKSWU/2024-25/BD/WORK_INDENT10
titleConstruction of first floor work of Dashmanostva building at Jnana shakti campus K.S.A.W.U. Vijayapura
descriptionConstruction of first floor work of Dashmanostva building at Jnana shakti campus K.S.A.W.U. Vijayapura
categoryWORKS
categoryTextWorks
ecv30725111.56
deptNameKarnataka State Akkamahadevi Womens University
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location4419
locationNameKSW University Vijayapura
provisionalAmount36255630.27
groupOverheadTotalNone
fileNumber2062024
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17200791780000NoneNoneBuildingsConstruction of first floor work of Dashamanostava Building at KSAWU Vijayapur30725111.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3449799122649None001Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column (Vol 1, Pg.no.16, Item no. 2.5.1) Cum11271.011271.058.0FalseNoneNoneFalseNoneFalse653718.00
3449800122649None002Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintels (Vol 1, Pg.no.16, Item no. 2.5.1) Cum10608.010608.027.0FalseNoneNoneFalseNoneFalse286416.00
3449801122649None003Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chajja (Vol 1, Pg.no.16, Item no. 2.5.1) Cum9613.59613.510.0FalseNoneNoneFalseNoneFalse96135.00
3449802122649None004Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Staircase waist Slab (Vol 1, Pg.no.16, Item no. 2.5.1) Cum9945.09945.08.0FalseNoneNoneFalseNoneFalse79560.00
3449803122649None005Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam (Vol 1, Pg.no.16, Item no. 2.5.2) Cum10608.010608.073.56FalseNoneNoneFalseNoneFalse780324.480
3449804122649None006Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab (Vol 1, Pg.no.16, Item no. 2.5.3) Cum9945.09945.0244.06FalseNoneNoneFalseNoneFalse2427176.70
3449805122649None007Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in Superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol 2, Pg.no.14, Item no. 6.8) Cum7969.07969.0400.0FalseNoneNoneFalseNoneFalse3187600.00
3449806122649None008Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a)) Tonne89457.089457.076.0FalseNoneNoneFalseNoneFalse6798732.00
3449807122649None009Providing and fixing in position Mathi/Nandi wood half panelled shutters at bottom and half glazed at top for window shutters with stiles and rails of 35mm thick, 75mm wide in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (Vol 2, Pg.no.102, Item no. 12.37) Sqm6456.06456.058.65FalseNoneNoneFalseNoneFalse378644.40
3449808122649None010Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Vol 2, Pg.no.99, Item no. 12.11) Cum138074.0138074.02.06FalseNoneNoneFalseNoneFalse284432.440
3449809122649None011Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam (Vol 2, Pg.no.104, Item no. 12.55.1) Sqm2366.02366.024.36FalseNoneNoneFalseNoneFalse57635.760
3449810122649None012Providing and fixing of bright finished brass quality fixtures to the doors such as aldrop, handle, latches tower bolt etc… including labour charges complete as per the direction of the Engineer in charge (MR) Each3000.03000.030.0FalseNoneNoneFalseNoneFalse90000.00
3449811122649None013Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Vol 2, Pg.no.86, Item no. 11.34A) Kg168.0168.02800.0FalseNoneNoneFalseNoneFalse470400.00
3449812122649None014Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. (MR) Sqm5700.05700.066.0FalseNoneNoneFalseNoneFalse376200.00
3449813122649None015Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineering-charge. (Vol 2, Pg.no.42, Item no. 8.6.1) Sqm323.0323.04600.0FalseNoneNoneFalseNoneFalse1485800.00
3449814122649None016Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.42, Item no. 8.9) Sqm385.0385.03070.0FalseNoneNoneFalseNoneFalse1181950.00
3449815122649None017Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, Including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (Vol 2, Pg.no.62, Item no. 9.21.2) Sqm1447.01447.01985.35FalseNoneNoneFalseNoneFalse2872801.450
3449816122649None018Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (Vol 2, Pg.no.60, Item no. 9.10) Sqm1106.01106.0225.0FalseNoneNoneFalseNoneFalse248850.00
3449817122649None019Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.51) Sqm100.0100.04400.0FalseNoneNoneFalseNoneFalse440000.00
3449818122649None020Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.51, Item no. 8.55.2) Sqm53.053.04400.0FalseNoneNoneFalseNoneFalse233200.00
3449819122649None021Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic ompound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.54.2) Sqm110.0110.04400.0FalseNoneNoneFalseNoneFalse484000.00
3449820122649None022Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.45, Item no. 8.27) Sqm53.053.02690.0FalseNoneNoneFalseNoneFalse142570.00
3449821122649None023Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.53, Item no. 8.75.1) Sqm111.0111.04950.0FalseNoneNoneFalseNoneFalse549450.00
3449822122649None024KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR) Sqm4741.44741.4165.15FalseNoneNoneFalseNoneFalse783042.210
3449823122649None025KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions using sections in combination of plain, single grove and double grove as per requirements for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683 kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet both side of approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistling and making good with cement mortar to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable size holes and fixing with cement mortar, with necessary opening for fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR) Sqm5082.75082.75.04FalseNoneNoneFalseNoneFalse25616.8080
3449824122649None026KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR) Sqm6593.26593.23.78FalseNoneNoneFalseNoneFalse24922.2960
3449825122649None027KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR) Sqm4637.54637.54.32FalseNoneNoneFalseNoneFalse20034.00
3449826122649None028Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (Vol 2, Pg.no.63, Item no. 9.28) Sqm4279.04279.0230.0FalseNoneNoneFalseNoneFalse984170.00
3449827122649None029Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cement (Vol 2, Pg.no.59, Item no. 9.6.1) Sqm1269.01269.075.0FalseNoneNoneFalseNoneFalse95175.00
3449828122649None030Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.47, Item no. 8.33.3) Sqm139.0139.0330.0FalseNoneNoneFalseNoneFalse45870.00
3449829122649None031French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.49, Item no. 8.46) Sqm295.0295.0152.49FalseNoneNoneFalseNoneFalse44984.550
3449830122649None032Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Coping (Vol 1, Pg.no.15, Item no. 2.1.3) Cum6630.06630.05.0FalseNoneNoneFalseNoneFalse33150.00
3449831122649None033Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1) Cum15912.015912.02.0FalseNoneNoneFalseNoneFalse31824.00
3449832122649None034Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1) Cum14586.014586.015.0FalseNoneNoneFalseNoneFalse218790.00
3449833122649None035Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1) Cum13260.013260.022.5FalseNoneNoneFalseNoneFalse298350.00
3449834122649None036Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a) Tonne89457.089457.04.0FalseNoneNoneFalseNoneFalse357828.00
3449835122649None037KSRB 10-3: Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kgl sqm of cement admixed with proprietary water proofing compound conforming to 18:2645 over the RCC slab after cleaning the before treatment. (b) Laying cement concrete using broken brick bats 25mm to 1OOmm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound 18:2645 20mm thick layer of cement 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300mm height including off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement of mix 1:4 admixed with water proofing compound and finally finishing the surface with trowel and neat cement and making of 300x300mm square. (e) the whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test including cost of materials complete as per specifications (MR) Sqm1102.21102.22000.0FalseNoneNoneFalseNoneFalse2204400.00
3449836122649None038Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 (Vol 2, Pg.no.126, Item no. 13.54) Each6278.06278.04.0FalseNoneNoneFalseNoneFalse25112.00
3449837122649None039Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 lt low level white P.V.C. flushing including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Vol 2, Pg.no.131, Item no. 14.11) Each4884.04884.06.0FalseNoneNoneFalseNoneFalse29304.00
3449838122649None040Providing and fixing white vitreous china pedestal type water closet European type with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend,overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (Vol 2, Pg.no.131, Item no. 14.2.1) Each4838.04838.04.0FalseNoneNoneFalseNoneFalse19352.00
3449839122649None041Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (Vol 2, Pg.no.132, Item no. 14.7.1) Each3082.03082.010.0FalseNoneNoneFalseNoneFalse30820.00
3449840122649None042Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 g (Vol 2, Pg.no.137, Item no. 14.39) Each195.0195.04.0FalseNoneNoneFalseNoneFalse780.00
3449841122649None043Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 25 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.1) Nos549.0549.010.0FalseNoneNoneFalseNoneFalse5490.00
3449842122649None044Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 32 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.2) Nos598.0598.010.0FalseNoneNoneFalseNoneFalse5980.00
3449843122649None045Providing and fixing brass stop cock of approved quality :20 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.3.2) Nos305.0305.020.0FalseNoneNoneFalseNoneFalse6100.00
3449844122649None046Providing and fixing brass stop cock of approved quality :15 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.2.1) Nos286.0286.010.0FalseNoneNoneFalseNoneFalse2860.00
3449845122649None047Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 g (Vol 2, Pg.no.120, Item no. 13.20.2) Nos314.0314.010.0FalseNoneNoneFalseNoneFalse3140.00
3449846122649None048Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia (Vol 2, Pg.no.120, Item no. 13.22.1.1) Nos41.041.012.0FalseNoneNoneFalseNoneFalse492.00
3449847122649None049Providing and fixing 100 mm sand cast iron grating for gully trap (Vol 2, Pg.no.136, Item no. 14.29) Each47.047.012.0FalseNoneNoneFalseNoneFalse564.00
3449848122649None050Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 25mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.114, Item no. 10.1.1) m48.048.0150.0FalseNoneNoneFalseNoneFalse7200.00
3449849122649None051Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 32mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.113, Item no. 10.1.2) m67.067.050.0FalseNoneNoneFalseNoneFalse3350.00
3449850122649None052Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia. (Vol 5, Pg.no.114, Item no. 10.2.1) m217.0217.040.0FalseNoneNoneFalseNoneFalse8680.00
3449851122649None053Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia. (Vol 5, Pg.no.114, Item no. 10.2.2) m288.0288.050.0FalseNoneNoneFalseNoneFalse14400.00
3449852122649None054Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.6) Each245.0245.020.0FalseNoneNoneFalseNoneFalse4900.00
3449853122649None055Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.8) Each492.0492.020.0FalseNoneNoneFalseNoneFalse9840.00
3449854122649None056Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp (Vol 2, Pg.no.176, Item no. 17.10.1) Kg1777.01777.05.0FalseNoneNoneFalseNoneFalse8885.00
3449855122649None057Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Vol 2, Pg.no.123, Item no. 13.34) l9.09.04000.0FalseNoneNoneFalseNoneFalse36000.00
3449856122649None058KSRB 8.6-1 : Providing and fixing on wall surface 2.5 kg/sq.cm H.D.P.E. rain down water pipes of approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of labour, complete as per specifications. 2.5 kg/sq.cm H.D.P.E. rain down water pipes 90 mm outer d (MR) m401.5401.5100.0FalseNoneNoneFalseNoneFalse40150.00
3449857122649None059Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Vol 2, Pg.no.187, Item no. 19.3) Cum2426.02426.011.81FalseNoneNoneFalseNoneFalse28651.060
3449858122649None060Providing and fixing of GI sheet with tubuluar steel structure with the self driven screws, bolts including nuts and washers complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (MR) Kg125.0125.0445.0FalseNoneNoneFalseNoneFalse55625.00
3449859122649None061Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Vol 2, Pg.no.26, Item no. 7.38) Sqm568.0568.0240.0FalseNoneNoneFalseNoneFalse136320.00
3449860122649None111Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws." 19/20mm dia 2mm thick Mtr69.069.050.0FalseNoneNoneFalseNoneFalse3450.00
3449861122649None112Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws."25mm dia 2mm thick Mtr81.081.050.0FalseNoneNoneFalseNoneFalse4050.00
3449862122649None113Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32mm dia 2.5mm thick Mtr106.0106.015.0FalseNoneNoneFalseNoneFalse1590.00
3449863122649None121Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"19/20mm dia 2mm thick Mtr66.066.0950.0FalseNoneNoneFalseNoneFalse62700.00
3449864122649None122Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"25mm dia 2mm thick Mtr78.078.0450.0FalseNoneNoneFalseNoneFalse35100.00
3449865122649None123upplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary32mm dia 2.5mm thick Mtr103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
3449866122649None131Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 19/20mm dia 2mm thick Mtr68.068.0185.0FalseNoneNoneFalseNoneFalse12580.00
3449867122649None132Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 25mm dia 2mm thick Mtr79.079.050.0FalseNoneNoneFalseNoneFalse3950.00
3449868122649None133Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 32mm dia 2.5mm thick Mtr99.099.015.0FalseNoneNoneFalseNoneFalse1485.00
3449869122649None151Supplying and fixing PVC/Metal conduit accessories."Deep junction boxes"Supplying and fixing PVC/metal conduitDeep Junction Box. P-2" a) 19/20 mm deep junction boxes Each49.049.0185.0FalseNoneNoneFalseNoneFalse9065.00
3449870122649None152Supplying and fixing PVC/Metal conduit accessories."Deep junction boxes"Supplying and fixing PVC/metal conduitDeep Junction Box. P-2"b) 25 mm deep junction boxes Each56.056.075.0FalseNoneNoneFalseNoneFalse4200.00
3449871122649None153Supplying and fixing PVC/Metal conduit accessories.Each61.061.015.0FalseNoneNoneFalseNoneFalse915.00
3449872122649None171Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3a) Upto 50 mm conduit in brick wall Mtr29.029.0150.0FalseNoneNoneFalseNoneFalse4350.00
3449873122649None172Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3b) Upto 50 mm conduit in CC floor Mtr69.069.015.0FalseNoneNoneFalseNoneFalse1035.00
3449874122649None181Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3a)20 mm dia Mtr28.028.0150.0FalseNoneNoneFalseNoneFalse4200.00
3449875122649None182Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3b)25 mm dia Mtr35.035.015.0FalseNoneNoneFalseNoneFalse525.00
3449876122649None191Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3a)20 mm dia Mtr19.019.045.0FalseNoneNoneFalseNoneFalse855.00
3449877122649None192Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3b)25 mm dia Mtr22.022.025.0FalseNoneNoneFalseNoneFalse550.00
3449878122649None193Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3c)32 mm dia Mtr29.029.010.0FalseNoneNoneFalseNoneFalse290.00
3449879122649None110Supplying and fixing of ""S"" hook made out of 14 mm dia M.S. Rod. P-3 Each52.052.066.0FalseNoneNoneFalseNoneFalse3432.00
3449880122649None111Supplying and fixing M.S. rafter clamp made out of M.S. flat & 14 mm M.S. rod. P- 3 Each160.0160.066.0FalseNoneNoneFalseNoneFalse10560.00
3449881122649None112Supplying and fixing metal fan box with round hook. P-3 Each117.0117.066.0FalseNoneNoneFalseNoneFalse7722.00
3449882122649None211Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet."a) Short point upto 3 Mtr from tapping point to out let via switch.""a) Short point upto 3 Mtr from tapping point to out let via switch." Point285.0285.034.0FalseNoneNoneFalseNoneFalse9690.00
3449883122649None212 Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch Point394.0394.050.0FalseNoneNoneFalseNoneFalse19700.00
3449884122649None213Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Point570.0570.075.0FalseNoneNoneFalseNoneFalse42750.00
3449885122649None214 Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. "d)Two outlet in a row ,above 3 Mtrs. Upto 6 Mtrs. From tapping point to outlet via switches." Point708.0708.034.0FalseNoneNoneFalseNoneFalse24072.00
3449886122649None215 Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. e)Three outlet in a row,above 6 Mtrs. Up to 10 Mtrs. From tapping point to out let via switches. Point1035.01035.035.0FalseNoneNoneFalseNoneFalse36225.00
3449887122649None221Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a "a) Short point upto 3 Mtr from tapping point to out let via switch." Point269.0269.034.0FalseNoneNoneFalseNoneFalse9146.00
3449888122649None222Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch Point379.0379.050.0FalseNoneNoneFalseNoneFalse18950.00
3449889122649None223Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Point555.0555.075.0FalseNoneNoneFalseNoneFalse41625.00
3449890122649None224Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a d) Two out let in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches. Point677.0677.034.0FalseNoneNoneFalseNoneFalse23018.00
3449891122649None225Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a e) Three out let in a row, above 6 Mtrs upto 10 Mtrs from tapping point to out let via switches. Point989.0989.035.0FalseNoneNoneFalseNoneFalse34615.00
3449892122649None231Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.0 Sqmm Mtr19.019.01800.0FalseNoneNoneFalseNoneFalse34200.00
3449893122649None232Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.5 Sqmm Mtr26.026.02880.0FalseNoneNoneFalseNoneFalse74880.00
3449894122649None233Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 2.5 Sqmm Mtr42.042.02880.0FalseNoneNoneFalseNoneFalse120960.00
3449895122649None234Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 4 Sqmm Mtr63.063.0540.0FalseNoneNoneFalseNoneFalse34020.00
3449896122649None331Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 1-2 way Each103.0103.017.0FalseNoneNoneFalseNoneFalse1751.00
3449897122649None332Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 3 wayEach124.0124.05.0FalseNoneNoneFalseNoneFalse620.00
3449898122649None334Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 6 way Each173.0173.04.0FalseNoneNoneFalseNoneFalse692.00
3449899122649None335Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 8wayEach219.0219.010.0FalseNoneNoneFalseNoneFalse2190.00
3449900122649None336Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 10 wayEach261.0261.025.0FalseNoneNoneFalseNoneFalse6525.00
3449901122649None338Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 18 wayEach339.0339.015.0FalseNoneNoneFalseNoneFalse5085.00
3449902122649None341Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 1-2 way Each138.0138.017.0FalseNoneNoneFalseNoneFalse2346.00
3449903122649None342Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 3 way Each159.0159.05.0FalseNoneNoneFalseNoneFalse795.00
3449904122649None351Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.a) 1 to 2 Module Each137.0137.017.0FalseNoneNoneFalseNoneFalse2329.00
3449905122649None353Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.b) 4 Module Each175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3449906122649None354Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box. 8 module Each284.0284.04.0FalseNoneNoneFalseNoneFalse1136.00
3449907122649None355Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.e)10-12 Module Each344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3449908122649None358Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.f)16-18 Module Each457.0457.025.0FalseNoneNoneFalseNoneFalse11425.00
3449909122649None361Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. a) 6 Amps one way. Each102.0102.0300.0FalseNoneNoneFalseNoneFalse30600.00
3449910122649None362Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. b) 6 A amps Two way switch. Each166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
3449911122649None363Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.c) 6 Amps 5 way Socket Each171.0171.055.0FalseNoneNoneFalseNoneFalse9405.00
3449912122649None364Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.d) Stepped Fan Regulator. Each357.0357.060.0FalseNoneNoneFalseNoneFalse21420.00
3449913122649None368Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.g)16 Amps one way switch. Each180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3449914122649None3611Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. j)6/16 Amps Universal socket. Each236.0236.020.0FalseNoneNoneFalseNoneFalse4720.00
3449915122649None370Supplying & Fixing 32 Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & Competely wired on exixting box. Each646.0646.04.0FalseNoneNoneFalseNoneFalse2584.00
3449916122649None310Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws. a)80 mm dia Each15.015.0300.0FalseNoneNoneFalseNoneFalse4500.00
3449917122649None3103Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws. b)110 mm dia Each21.021.050.0FalseNoneNoneFalseNoneFalse1050.00
3449918122649None311Supplying and fixing of 50 mm wooden plug,tapered from 50x50 mm to 25x25mm and fixing by using binding wire before concreting a roof slab. Each12.012.0200.0FalseNoneNoneFalseNoneFalse2400.00
3449919122649None3121Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. a) 1 way gang box Each23.023.010.0FalseNoneNoneFalseNoneFalse230.00
3449920122649None3122Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. b) 2 to 4 way gang box Each32.032.010.0FalseNoneNoneFalseNoneFalse320.00
3449921122649None3123Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. c) 6 to 10 way gang box Each53.053.010.0FalseNoneNoneFalseNoneFalse530.00
3449922122649None3164Supplying & Fixing PBBC/Bakelite Straight or Slant batten holder wiring,with in 6Amp 230 V lamps. Each71.071.0300.0FalseNoneNoneFalseNoneFalse21300.00
3449923122649None1132Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition." 1x4'-22 Watts Each690.0690.0200.0FalseNoneNoneFalseNoneFalse138000.00
3449924122649None1163Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA LED modular down light 2'x2' /1'x4'42-55 WEach4553.04553.02.0FalseNoneNoneFalseNoneFalse9106.00
3449925122649None1182Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70% 2 Years against any manufacturing defect LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 120 WattEach4024.04024.06.0FalseNoneNoneFalseNoneFalse24144.00
3449926122649None5181Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 Amps SP Each415.0415.025.0FalseNoneNoneFalseNoneFalse10375.00
3449927122649None5182Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40 Amps SP Each793.0793.05.0FalseNoneNoneFalseNoneFalse3965.00
3449928122649None5184Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 Amps DP Each739.0739.04.0FalseNoneNoneFalseNoneFalse2956.00
3449929122649None5185Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40 Amps DP Each1060.01060.02.0FalseNoneNoneFalseNoneFalse2120.00
3449930122649None5187Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 AmpsTPN Each1717.01717.02.0FalseNoneNoneFalseNoneFalse3434.00
3449931122649None5189Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40-63 Amps TPN Each3044.03044.02.0FalseNoneNoneFalseNoneFalse6088.00
3449932122649None51913Supplying and fixing regular MCB distribution boards on wall/ wood board/flush mounting using required clamps/bolts/nuts.,with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc.Made out of 14 SWG MS enclosure.Double Door 12 way TP &N Each8735.08735.06.0FalseNoneNoneFalseNoneFalse52410.00
3449933122649None5124Supplying of on load change over switches 4 pole, AC-23A Duty, 415 V, 50 Hz, AC Supply a) 200 Amps" Each15249.015249.01.0FalseNoneNoneFalseNoneFalse15249.00
3449934122649None5146Supplying and fixing of 4 pole power contactor with NO/NC contacts on exsiting panel board using necessary bolts and complete wiring with AC-3 rating and as per IS-13947, (100-125 Amps) Each16606.016606.01.0FalseNoneNoneFalseNoneFalse16606.00
3449935122649None51510Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole a) 125-160 Amps 25ka Each10341.010341.01.0FalseNoneNoneFalseNoneFalse10341.00
3449936122649None51212Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole Each17301.017301.01.0FalseNoneNoneFalseNoneFalse17301.00
3449937122649None533Supplying of multi function digital meter with three line back light LCD type displayy for voltage, Current, Ferquency, power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completetly wired as required with communication port and class 0.5s accuracy Each9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3449938122649None053Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden CT. Class 0.5 accuracy with tape wound Each526.0526.03.0FalseNoneNoneFalseNoneFalse1578.00
3449939122649None054Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC 50HZ 12/24V DC Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3449940122649None5401Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete.a)100Amps 4X30X6mm Aluminum strips Mtr2465.02465.010.0FalseNoneNoneFalseNoneFalse24650.00
3449941122649None5402Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete. b)250 Amps 4X30X10mm Aluminum strips Mtr3435.03435.08.0FalseNoneNoneFalseNoneFalse27480.00
3449942122649None5421Fabricating Supplying and mounting MS box made out. SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equppied with tamper proof loacking arrangment, with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. (16SWG) Sq CM0.430.4375000.0FalseNoneNoneFalseNoneFalse32250.00
3449943122649None061Supplying,fixing, wiring, earth electrode for grounding conduits, I.C. cutouts & other equipments on the meter board using 40mm dia 2.90 thick G.I. pipe 2.5m long buried in a pit. The pit should be filled with equal proprotion of salt & charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc. is to be established through G.I.wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers & checknuts etc, the pipe shall have 16 through holes of 12mm dia. SR 2018-19 Each2999.72999.72.0FalseNoneNoneFalseNoneFalse5999.40
3449944122649None063Supplying & running of G.I/Cu strips for grounding connections, using necessary fixing materials as required.SR 2018-19 I) G.I Strip a) 25 X 3 mm Mtr75.075.010.0FalseNoneNoneFalseNoneFalse750.00
3449945122649None615Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only)25 mm dia Each84.084.04.0FalseNoneNoneFalseNoneFalse336.00
3449946122649None6152Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only) 50mm dia Each1785.01785.02.0FalseNoneNoneFalseNoneFalse3570.00
3449947122649None617Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.SR 2018-19 50 sqmm Long barrel Each60.060.010.0FalseNoneNoneFalseNoneFalse600.00
3449948122649None061Supplying exhaust fan Of 1440 RPM of 300mm size with bracket blades suitable for operate on 230V 50Hz. AC supply complete. Each1492.01492.04.0FalseNoneNoneFalseNoneFalse5968.00
3449949122649None631Supplying Capacitor type Ceiling Fan complete with down rod blades, shackle, canopies etc., for operation on 230Volts,50 cycles. Single ohase AC Supply conforming to ISS-374-1979 and with double ball bearing system. Regular Model (48" Sweep) Each2984.02984.060.0FalseNoneNoneFalseNoneFalse179040.00
3449950122649None344Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 6 wayEach220.0220.04.0FalseNoneNoneFalseNoneFalse880.00
3449951122649None345Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 8 wayEach261.0261.010.0FalseNoneNoneFalseNoneFalse2610.00
3449952122649None346Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 10 wayEach319.0319.025.0FalseNoneNoneFalseNoneFalse7975.00
3449953122649None348Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 18 wayEach405.0405.015.0FalseNoneNoneFalseNoneFalse6075.00
3449954122649None615Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only) 50mm dia Each255.0255.02.0FalseNoneNoneFalseNoneFalse510.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17200791870000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17200791870000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17200791870000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17200791870000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17200791870000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17200792300000NoneNoneELIGIBILITYThe Bidders must follow all the conditions mentioned in the Tender documentsNone
17200892660000NoneNoneELIGIBILITYBidders are advised to visit the site and get themselves registered in the KSWU before participation in the Tender(The site visit letter will be issued on between the 01/08/2024 to 05/08/2024 within office hours)None
17200893020001NoneNoneELIGIBILITYThe bidders must follow K/W4 and qualification criteria 3 of slandered bid documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneAs per Tender DocumentsOthersAs per Tender Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
As per Tender DocumentsTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayapuraVijayapuraBijapurBIJAPURKSAWU VijayapurNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1720089441000
version0
createdDateNone
modifiedDateNone
blockNumberADM Block KSAWU Vijayapur
streetNone
cityVijayapur
stateKarnataka
pin586108
tenderRecallDTONone