createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720165961680
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1880.00
emd150300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-07-2024 16:00:00
tenderQueryClose12-07-2024 15:59:00
technicalBidOpen15-07-2024 11:00:00
publishedDate05-07-2024 13:43:25
publishedByPostRDPR_EE_DIV_MDG
publishedByUserKPE14743 - R DAYANANDA
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonEE PRED Madhugiri
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08137282326
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1720165961683
version12
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT5421/CALL-2
titleConstruction of 3 Rooms at PU College in Handanakere village in CN Halli taluk
descriptionConstruction of 3 Rooms at PU College in Handanakere village in CN Halli taluk
categoryWORKS
categoryTextWorks
ecv7505388.70
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location972
locationNameRDPR Division Office Madhugiri
provisionalAmount7515000.0
groupOverheadTotal0.0
fileNumber154
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17201659620001NoneNoneBuildingsConstruction of 3 Rooms at PU College in Handanakere village in CN Halli taluk7505388.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3457990123160Nonecode01Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (P.no 5 I.no 1.4.1)Vo1) CSR 2021-22Sqm285.56285.56176.99FalseNoneNoneFalseNoneFalse50541.26440
3457991123160Nonecode02Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) (P.no 15 I.no 2.1.2)Vol 1 cc bed1:4:8Cum6683.526683.5263.11FalseNoneNoneFalseNoneFalse421796.94720
3457992123160Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.no 9 I.no 5.3)Vol2)Cum7321.97321.932.31FalseNoneNoneFalseNoneFalse236570.5890
3457993123160Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.no 9 I.no 5.4)Vol 2)Cum7539.027539.0224.01FalseNoneNoneFalseNoneFalse181011.87020
3457994123160Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.no 7 I.no 1.9)Vol 1Cum313.88313.88123.83FalseNoneNoneFalseNoneFalse38867.76040
3457995123160Nonecode06Additional tiles for form work centring fondation up to plinth (P.no 115 I.no 1)Vol 1Cum593.49593.4964.25FalseNoneNoneFalseNoneFalse38131.73250
3457996123160Nonecode07Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost f steel reinforcement & formwork to be paid separately) (P.no 15 I.no 2.2.1)Vol 1)Cum7418.667418.6663.4FalseNoneNoneFalseNoneFalse470343.0440
3457997123160Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (P.no 15 I.no 2.1.4)Vol 1)Cum7336.057336.0510.06FalseNoneNoneFalseNoneFalse73800.6630
3457998123160Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.no 16 I.no 2.4.2)Vol 1)Cum7461.147461.1410.28FalseNoneNoneFalseNoneFalse76700.51920
3457999123160Nonecode10Additional tiles for form work centring fondation up to plinth (P.no 112 I.no 2)Vol 1Cum3709.333709.3313.02FalseNoneNoneFalseNoneFalse48295.47660
3458000123160Nonecode11Additional tiles for form work centring fondation up to plinth (P.no 112 I.no 16)Vol 1Cum3730.573730.5710.27FalseNoneNoneFalseNoneFalse38312.95390
3458001123160Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregate as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mmnominal size graded crushed coarse aggregates (P.no 17 I.no 2.5.1)Vol 1)Cum7823.47823.478.06FalseNoneNoneFalseNoneFalse610694.6040
3458002123160Nonecode13Additional tiles for form work centring fondation up to plinth (P.no 112 I.no 15)Vol 1Cum3911.73911.778.05FalseNoneNoneFalseNoneFalse305308.1850
3458003123160Nonecode14KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of nominal mix 1:1.5:3 with 12mm and down size graded granite metal, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 (P.no 15 I.no 4.19)Sqm523.92523.9220.6FalseNoneNoneFalseNoneFalse10792.7520
3458004123160Nonecode15Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work (p.no 14 I.no 6.8)Vol 2)Cum9403.429403.4284.7FalseNoneNoneFalseNoneFalse796469.6740
3458005123160Nonecode16Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.no 18 I.no 2.11.a)Vol 1)MT105559.26105559.2613.63FalseNoneNoneFalseNoneFalse1438772.71380
3458006123160Nonecode17Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (p.NO 41 I.no 8.1.1)Vol 2Sqm300.9300.9573.78FalseNoneNoneFalseNoneFalse172650.4020
3458007123160Nonecode18Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(P.no 41 I.no 8.2.1)Vol 2)Sqm348.1348.1653.32FalseNoneNoneFalseNoneFalse227420.6920
3458008123160Nonecode19Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.no 60 I.no 9.12.2)V2)Sqm1351.11351.1313.78FalseNoneNoneFalseNoneFalse423948.1580
3458009123160Nonecode20Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curingcomplete as per specification. (P.no 65 I.no 9.40)Vol 2)Sqm1099.761099.7688.25FalseNoneNoneFalseNoneFalse97053.820
3458010123160Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (P.no 86 I.no 11.34A)Vol 2)Kgs198.24198.241260.0FalseNoneNoneFalseNoneFalse249782.40
3458011123160Nonecode22Providing and fixing on wall face uplasticised Rigid PVC rain water pipes conforimng to IS : 13592 Type A, including joiting with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (I) Signle Socketed pipes 100 mm Diameter (P.no 2 I.no 13.48)Vo2)Mtr343.38343.3824.0FalseNoneNoneFalseNoneFalse8241.120
3458012123160Nonecode23Supplying & fixing GI pipe 40 mm Dia (P.no 4-23 I.no 362)Vol 2Mtr428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3458013123160Nonecode24PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.no 110 I.no 12.84)Vol 2Sqm5927.145927.1442.0FalseNoneNoneFalseNoneFalse248939.880
3458014123160Nonecode25Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.no 83 I.no 11.28)Vol 2Kgs666.7666.7655.2FalseNoneNoneFalseNoneFalse436821.840
3458015123160Nonecode26Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Pno 77 I.no 11.5.1)Vol 2)Sqm5284.045284.049.75FalseNoneNoneFalseNoneFalse51519.390
3458016123160Nonecode27Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofingmembrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. Thewaterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofingmembrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (P.no 149 I.no 15.1)Vol 2Sqm964.06964.06295.14FalseNoneNoneFalseNoneFalse284532.66840
3458017123160Nonecode28Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete (P.no 268 I.no 37.30)PWD SR)Each921.58921.5813.8FalseNoneNoneFalseNoneFalse12717.8040
3458018123160Nonecode29Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.no 46 I.no 8.30)Vol 2)Sqm205.32205.32653.32FalseNoneNoneFalseNoneFalse134139.66240
3458019123160Nonecode30Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge (P.no 50 I.no 8.51)Vol 2)Sqm118.0118.0573.78FalseNoneNoneFalseNoneFalse67706.040
3458020123160Nonecode31Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.no 48 I.no 8.39)Vol 2Sqm149.86149.86573.78FalseNoneNoneFalseNoneFalse85986.67080
3458021123160Nonecode32Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(p.no 47 I.no 8.33.3)Vol 2Sqm164.02164.02197.1FalseNoneNoneFalseNoneFalse32328.3420
3458022123160Nonecode33Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickMtr77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3458023123160Nonecode34Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thickMtr80.2480.2460.0FalseNoneNoneFalseNoneFalse4814.40
3458024123160Nonecode35Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.3) 135 x 75 x 65 mmEach164.02164.026.0FalseNoneNoneFalseNoneFalse984.120
3458025123160Nonecode36Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.7) 200 x 200 x 65 mmEach410.64410.643.0FalseNoneNoneFalseNoneFalse1231.920
3458026123160Nonecode37Supplying and fixing PVC/metal conduit Deep junction box - 32 mm deep Junction boxEach71.9871.9821.0FalseNoneNoneFalseNoneFalse1511.580
3458027123160Nonecode38Supplying And Fixing Metal Fan Box with Round Hook.Nos138.06138.0621.0FalseNoneNoneFalseNoneFalse2899.260
3458028123160Nonecode39Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch boxPoint447.22447.2230.0FalseNoneNoneFalseNoneFalse13416.60
3458029123160Nonecode40Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 1.5 mm2Mtr30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3458030123160Nonecode41Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 mm2Mtr202.96202.9690.0FalseNoneNoneFalseNoneFalse18266.40
3458031123160Nonecode42Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 wayEach204.14204.146.0FalseNoneNoneFalseNoneFalse1224.840
3458032123160Nonecode43Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 18 wayEach400.02400.023.0FalseNoneNoneFalseNoneFalse1200.060
3458033123160Nonecode44Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3) 6 WayEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3458034123160Nonecode45Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box6) 18 WayEach539.26539.263.0FalseNoneNoneFalseNoneFalse1617.780
3458035123160Nonecode46Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 1)6A One Way SwitchEach120.36120.3621.0FalseNoneNoneFalseNoneFalse2527.560
3458036123160Nonecode47Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 4) Stepped Fan Regulator Two ModuleEach421.26421.269.0FalseNoneNoneFalseNoneFalse3791.340
3458037123160Nonecode48Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 8) 16A One Way SwitchEach212.4212.46.0FalseNoneNoneFalseNoneFalse1274.40
3458038123160Nonecode49Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 11) 6/16A Universal SocketEach278.48278.483.0FalseNoneNoneFalseNoneFalse835.440
3458039123160Nonecode50Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 13) RJ45/I.O Outlet Cat-6Each397.66397.663.0FalseNoneNoneFalseNoneFalse1192.980
3458040123160Nonecode51Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 4 WayEach12188.2212188.221.0FalseNoneNoneFalseNoneFalse12188.220
3458041123160Nonecode52Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. - 32-40A 2 poleEach5379.625379.621.0FalseNoneNoneFalseNoneFalse5379.620
3458042123160Nonecode53Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32 A SPEach489.7489.71.0FalseNoneNoneFalseNoneFalse489.70
3458043123160Nonecode54Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach3521.123521.126.0FalseNoneNoneFalseNoneFalse21126.720
3458044123160Nonecode55Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each201.78201.786.0FalseNoneNoneFalseNoneFalse1210.680
3458045123160Nonecode56Supplying of .....feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 4' - 20/22 WEach814.2814.221.0FalseNoneNoneFalseNoneFalse17098.20
3458046123160Nonecode57Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaEach5022.085022.081.0FalseNoneNoneFalseNoneFalse5022.080
3458047123160Nonecode58Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.Each1628.41628.41.0FalseNoneNoneFalseNoneFalse1628.40
3458048123160Nonecode59BESCOM Deposite including supervision and Agreement chargesEach1180.01180.01.0FalseNoneNoneFalseNoneFalse1180.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17201659620000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17201659620000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17201659620000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17201659620000NoneNoneELIGIBILITYContractors must quote the rate including all taxesNone
17201659620000NoneNoneELIGIBILITYclass 3 and above contractors are eligiableNone
17201660140000NoneNoneELIGIBILITYCONTRACTORS MUST QUOTE THE RATE INCLUDING ALL TAXESNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactorily completed as prime contractor, at least one similar nature of work value not less than Rs. 37.58 Lakhs executed in any one financial yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneEarthwork:141.60 Sqm,Steel:10.92 MT,PCC/RCC/CC:196.41 Cum,Flooring:251.03 Sqm,Brick work:67.76Cum,Plastering:981.68 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAchieved in atleast two financial years a minimum financial turnover (in all classes of Civil Engineering construction works only of Rs 150.30 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of no less than Rs.25.03 Lakhs(Credit lines/ letter of credit/ certificates from nationalized banksOthersliquid assets
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD REGISTRED LICENSEOthersRDPR REGISTERED LICISENCE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
work done certificatesTrueTechnical Bid
Similar work done certificates quantitywiseTrueTechnical Bid
PWD REGISTRATION LICENSETrueTechnical Bid
LOC isuued from bankTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone