| 3462264 | 123444 | None | PWD SR 2023-24 vol-1 I.no-1.14 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. vol 1, 1.14 pg no 8 | Cum | 107.1 | 107.1 | 80.16 | False | None | None | False | None | False | 8585.136 | 0 |
| 3462265 | 123444 | None | PWD SR 2023-24 vol-1 I.no-1.9 | FILLING WITH MORRUM : Filling available excavated earth (excluding rocks) in sides of foundation upto plinth in layers not exceeding 20cms in depth, compacting each deposited layers by ramming after watering with lead upto 50m and fill upto 1.5m including cost of all labour, complete as per specifications. vol 1,1.9 pg no 7 | Cum | 279.3 | 279.3 | 67.932 | False | None | None | False | None | False | 18973.4076 | 0 |
| 3462266 | 123444 | None | PWD SR 2023-24 vol-5 I.no-A130A | Providing and Filling in foundation with granite/trap broken metal 100 mm & down size & with approved sand including handpacking ramming watering including cost of all materials and labour with all lead and lift complete as per specifications ( vol 5 9,A130A Pg no 64) | Cum | 2816.1 | 2816.1 | 5.916 | False | None | None | False | None | False | 16660.0476 | 0 |
| 3462267 | 123444 | None | PWD SR 2023-24 vol-1 I.no-2.1.4 | PCC : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 11.58 | False | None | None | False | None | False | 75592.503 | 0 |
| 3462268 | 123444 | None | PWD SR 2023-24 vol-1 I.no-2.4.2 | RCC :Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol:1 P.NO.17 I.No:2.4.2) | Cum | 6639.15 | 6639.15 | 35.344 | False | None | None | False | None | False | 234654.1176 | 0 |
| 3462269 | 123444 | None | PWD SR 2023-24 vol-2 I.no-6.1 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. vol 2,6.1,pg no 13 | Cum | 8631.0 | 8631.0 | 42.6282 | False | None | None | False | None | False | 367923.9942 | 0 |
| 3462270 | 123444 | None | PWD SR Vol 2 Pg No. A-7 Sl NO. 24 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations ,footings,bases of columns for mass concrete including cost of all materials, labour complete as per specificaiton.Percentage on finished rate of concrete per m3. 8%
| Cum | 531.13 | 531.13 | 13.316 | False | None | None | False | None | False | 7072.52708 | 0 |
| 3462271 | 123444 | None | PWD SR Vol 2 Pg No. A-7 Sl NO. 24 | Providing and removing centering, shuttering, strutting, propping etc.forcolumns pillars,post and struts,suare rectangular/polygon in plan , including cost of all materials, labour complete as per specificaiton.
.Percentage on finished rate of concrete per m3. 70%
| Cum | 4647.4 | 4647.4 | 3.45 | False | None | None | False | None | False | 16033.53 | 0 |
| 3462272 | 123444 | None | PWD SR Vol 2 Pg No. A-7 Sl NO. 24 | Providing and removing centering, shuttering, strutting, propping etc.and removal form work for sides and soffits of beams,beam haunchings,cantilever girders,bressumers and lintel not exceeding 1m in depth , including cost of all materials, labour complete as per specificaiton.Percentage on finished rate of concrete per m3. 60% | Cum | 3983.49 | 3983.49 | 7.247 | False | None | None | False | None | False | 28868.35203 | 0 |
| 3462273 | 123444 | None | PWD SR 2023-24 Vol 3 I.No. 9.3 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for suspended floors,landing,balconiesthickness upto 200mm foundations , including cost of all materials, labour complete as per specificaiton.Percentage on finished rate of concrete per m3. 50% | MT | 3319.58 | 3319.58 | 6.632 | False | None | None | False | None | False | 22015.45456 | 0 |
| 3462274 | 123444 | None | PWD SR 2023-24 vol-2 I.no-8.8 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Retaining Wall, including cost of all materials, labour complete as per specificaiton.Percentage on finished rate of concrete per m3. 10% | Sqm | 663.9 | 663.9 | 9.806 | False | None | None | False | None | False | 6510.2034 | 0 |
| 3462275 | 123444 | None | PWD SR 2023-24 vol-2 I.no-8.7 | P/TMT Steel reinforcement : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.PWD SR Vol 3 Pg No.71 I.No.9.3 | Sqm | 82052.25 | 82052.25 | 3.85 | False | None | None | False | None | False | 315901.1625 | 0 |
| 3462276 | 123444 | None | PWD SR 2021-22 vol-2 Page no-42 I.no-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. vol2,Pg no 42, 8.8 | Sqm | 389.55 | 389.55 | 124.68 | False | None | None | False | None | False | 48569.094 | 0 |
| 3462277 | 123444 | None | PWD SR 2023-24 vol-2 I.no-11.34B | P/15mm thick plastering to inside walls : Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge. SR vol 2 [P.No-42/I.No-8.7] | Sqm | 309.75 | 309.75 | 196.82 | False | None | None | False | None | False | 60964.995 | 0 |
| 3462278 | 123444 | None | PWD SR 2023-24 vol-2 I.no-11.28 | P/12mm thick ceiling plastering with CM 1:3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3 to to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding including cost of all materials, labour, curing complete as per specifications.vol2, 8.6.1 | Sqm | 339.15 | 339.15 | 39.0 | False | None | None | False | None | False | 13226.85 | 0 |
| 3462279 | 123444 | None | PWD SR 2023-24 vol-2 I.no-9.28 | P/M.S.Grill to windows :Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. PWD SR Vol 2 Pg No.85 I.NO.11.34B | Sqm | 192.15 | 192.15 | 68.04 | False | None | None | False | None | False | 13073.886 | 0 |
| 3462280 | 123444 | None | PWD SR 2023-24 vol-2 Page no-84 I.no-11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials,labour, usage chargesof machinery complete as per specifications and as per directions of the Engineer-in-Charg | Kg | 593.25 | 593.25 | 54.0 | False | None | None | False | None | False | 32035.5 | 0 |
| 3462281 | 123444 | None | PWD SR 2023-24 vol-2 Page no-63 I.no-9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent | Sqm | 2589.3 | 2589.3 | 15.6 | False | None | None | False | None | False | 40393.08 | 0 |
| 3462282 | 123444 | None | PWD SR 2023-24 vol-2 Page no-60 I.no-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15624, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Vol 2, Pg no 60,9.11 | Sqm | 933.45 | 933.45 | 36.0 | False | None | None | False | None | False | 33604.2 | 0 |
| 3462283 | 123444 | None | PWD SR 2023-24 vol-2 Page no-45 I.no-8.29 | EXTERIOR PAINT Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in- | Sqm | 297.15 | 297.15 | 121.36 | False | None | None | False | None | False | 36062.124 | 0 |
| 3462284 | 123444 | None | PWD SR 2023-24 vol-2 Page no-123 I.no-14.3.1 | WALL CLADDING :Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15624 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complet | Sqm | 1161.3 | 1161.3 | 60.66 | False | None | None | False | None | False | 70444.458 | 0 |
| 3462285 | 123444 | None | PWD SR 2021-2022 Vol 2.pg no 50,8.51) | PUTTY INTERIOR Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Vol 2.pg no 50,8.51) | Sqm | 105.0 | 105.0 | 108.48 | False | None | None | False | None | False | 11390.4 | 0 |
| 3462286 | 123444 | None | PWD SR 2023-2024 Vol 2 (pg no:46,8.33.1) | P/Plastic Emulsion paint to inside wall & Ceiling : Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol 2 (pg no:46,8.33.1) | Sqm | 165.9 | 165.9 | 108.72 | False | None | None | False | None | False | 18036.648 | 0 |
| 3462287 | 123444 | None | PWD SR 2023-24 vol-2 Page no-123 I.no-14.3. | WATER CLOSET :Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid vol 2, pg no 123, 14.3.1 | Nos | 6275.85 | 6275.85 | 6.0 | False | None | None | False | None | False | 37655.1 | 0 |
| 3462288 | 123444 | None | vol 2 ,12.97.1 | DOOR PANELS :Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 3364.2 | 3364.2 | 11.34 | False | None | None | False | None | False | 38150.028 | 0 |
| 3462289 | 123444 | None | PWD SR 2021-2022 vol 2 ,11.30.2,pg no 83 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. vol 2 ,11.30.2,pg no 83 | Sqm | 1320.9 | 1320.9 | 4.0 | False | None | None | False | None | False | 5283.6 | 0 |
| 3462290 | 123444 | None | PWD SR Vol 2 Pg No.100 I.No.12.13.1 | DOOR FRAMES: Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.PWD SR Vol 2 Pg No.100 I.No.12.13.1 | Cum | 103755.75 | 103755.75 | 0.4 | False | None | None | False | None | False | 41502.3 | 0 |
| 3462291 | 123444 | None | PWD SR Vol2 pg no 119,13.28.3 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 25mm nominal bore, weighing not less than 62 g | No | 110.25 | 110.25 | 30.0 | False | None | None | False | None | False | 3307.5 | 0 |
| 3462292 | 123444 | None | Vol 2, Pg no 46, I.No 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol 2, Pg no 46, I.No 8.33.2 | Sqm | 144.9 | 144.9 | 40.0 | False | None | None | False | None | False | 5796.0 | 0 |
| 3462293 | 123444 | None | vol2, 11.46.1 ,pg no 91 | Providing and fixing aluminium tubular handle bar 32 mm outer dia,3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.: Anodized (AC 15 ) aluminium tubular handle bar including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer inCharge. | Nos | 615.3 | 615.3 | 12.0 | False | None | None | False | None | False | 7383.6 | 0 |
| 3462294 | 123444 | None | PWD SR 2021-2022 vol 2,14.7.3 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x400 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3009.3 | 3009.3 | 4.0 | False | None | None | False | None | False | 12037.2 | 0 |
| 3462295 | 123444 | None | Vol 2, Pg no 127,14.18.1 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White | Nos | 996.45 | 996.45 | 6.0 | False | None | None | False | None | False | 5978.7 | 0 |
| 3462296 | 123444 | None | vol 2,Pg no 128, 14.32.1 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Circular shape 450 mm dia | Nos | 1142.4 | 1142.4 | 6.0 | False | None | None | False | None | False | 6854.4 | 0 |
| 3462297 | 123444 | None | Vol 2,Pg no 130, 14.40.1 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 | Nos | 501.9 | 501.9 | 6.0 | False | None | None | False | None | False | 3011.4 | 0 |
| 3462298 | 123444 | None | vol2, 14.37.2 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms | No | 333.9 | 333.9 | 6.0 | False | None | None | False | None | False | 2003.4 | 0 |
| 3462299 | 123444 | None | 2nd Momerandum Item Added 8189C | Supp ly of PP R a lve P a st c H ea co rm n to 1 tc c 580 1 2008 a nd D N5t and a rds 807 7 8092 PPR Ball Valve plastic (Head ) 32mm. 2nd Momerandum Item Added 8189C | Nos | 360.15 | 360.15 | 10.0 | False | None | None | False | None | False | 3601.5 | 0 |
| 3462300 | 123444 | None | Vol 2, Pg no 117,13.13 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Vol 2, Pg no 117,13.13 | Nos | 888.3 | 888.3 | 8.0 | False | None | None | False | None | False | 7106.4 | 0 |
| 3462301 | 123444 | None | PWD SR WRD 3.61 | Providing & installing at site of work 100mm dia. Perforated corrugated PVC 3.61. pipes conforming to IS 9271 with prewrapped 250gsm. Geosynthetic filter material by laser guided trencher machine/by mechanical means including cost of pipe, filter material, pipe accessories and all taxes including all lead and lifts., complete and labour charges only for installation of site at work perforated corrugated PVC pipes including lowering into trenches, laying true to lines, level land and perfect leak proof linking at joints, fittings pipes accessories with all lead and lifts charges including the refilling the trench 50 cm around the pipe with gravel or selected earth available from the excavation etc., complete with all leads and lifts. . PWD SR WRD 3.61 | Rmtr | 371.7 | 371.7 | 20.0 | False | None | None | False | None | False | 7434.0 | 0 |
| 3462302 | 123444 | None | PWD Part 1 Elc Pg no 1,1.4.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick .PWD Part 1 Elc Pg no 1,1.4.1 | Rmtr | 71.4 | 71.4 | 150.0 | False | None | None | False | None | False | 10710.0 | 0 |
| 3462303 | 123444 | None | PWD Part 1 Elc Pg no 1,1.4.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75 x 75 x 65 mm PWD Part 1 Elc Pg no 1,1.4.1 | Nos | 365.4 | 365.4 | 20.0 | False | None | None | False | None | False | 7308.0 | 0 |
| 3462304 | 123444 | None | PWD Part 1 Elc Pg no 13, 5.19.1 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 16 Way SP & N. PWD Part 1 Elc Pg no 13, 5.18.5 | Nos | 3053.4 | 3053.4 | 2.0 | False | None | None | False | None | False | 6106.8 | 0 |
| 3462305 | 123444 | None | PWD part 1 Elc Pg no 2, 2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch PWD part 1 Elc Pg no 2, 2.1.2 | Rmtr | 413.7 | 413.7 | 16.0 | False | None | None | False | None | False | 6619.2 | 0 |
| 3462306 | 123444 | None | vol 5 I No.13.6.2 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.1.00 HP/0.75KW vol 5,pg no 158,6 P060 | No | 14605.5 | 14605.5 | 1.0 | False | None | None | False | None | False | 14605.5 | 0 |
| 3462307 | 123444 | None | PwD electrical items Part 1, PG no 4 ,2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010 .3C x 2.5 mm2 PwD electrical items Part 1, PG no 4 ,2.6.2 | Rmtr | 176.4 | 176.4 | 40.0 | False | None | None | False | None | False | 7056.0 | 0 |
| 3462308 | 123444 | None | PWD SR 2023-2024 Vol2 I No.13.34A | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI: 12701, colour of opaque white or as approved by Engineer-in-charge: The rate includes making necessary hes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
| 3462309 | 123444 | None | PWD SR Vol 2 I.No.13.32.3 | Providing and faxing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing This indudes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25mm Nominal dia pipes . PWD SR Vol 2 I.No.13.32.3 | Rmtr | 500.85 | 500.85 | 20.0 | False | None | None | False | None | False | 10017.0 | 0 |
| 3462310 | 123444 | None | Vol 5, P gno 22, I no 2.23.2 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: Vol 5, P gno 22, I no 2.23.2 | No | 10912.65 | 10912.65 | 2.0 | False | None | None | False | None | False | 21825.3 | 0 |
| 3462311 | 123444 | None | Vol 5,P g no 117,I.No 10.91 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.M100 Vol 5,P g no 117,I.No 10.91 | No | 16.8 | 16.8 | 15.0 | False | None | None | False | None | False | 252.0 | 0 |
| 3462312 | 123444 | None | Voi 5,Pg NO 117. I no 10.10.1 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Voi 5,Pg NO 117. I no 10.10.1 | No | 22.05 | 22.05 | 15.0 | False | None | None | False | None | False | 330.75 | 0 |
| 3462313 | 123444 | None | Vol 5,PG NO 118, I.NO 10.11.1 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Vol 5,PG NO 118, I.NO 10.11.1 | No | 25.2 | 25.2 | 15.0 | False | None | None | False | None | False | 378.0 | 0 |
| 3462314 | 123444 | None | Vol 5, Pg No 132, I NO 11.14.3 | Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any For 20 mm dia GI hexagonal nipple Vol 5, Pg No 132, I NO 11.14.3 | No | 135.45 | 135.45 | 15.0 | False | None | None | False | None | False | 2031.75 | 0 |
| 3462315 | 123444 | None | vol5, PG no 133, I no 11.15.3 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 20 mm dia GM (Copper alloy) Gate valves vol5, PG no 133, I no 11.15.3 | No | 1227.45 | 1227.45 | 2.0 | False | None | None | False | None | False | 2454.9 | 0 |
| 3462316 | 123444 | None | vol 6,pg no 10, 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A SP Switch vol 6,pg no 10, 3.14.1 | No | 57.75 | 57.75 | 30.0 | False | None | None | False | None | False | 1732.5 | 0 |
| 3462317 | 123444 | None | Vol6, pg no 10, 3.14.2 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A :Lamp Holder. Vol6, pg no 10, 3.14.2 | No | 73.5 | 73.5 | 15.0 | False | None | None | False | None | False | 1102.5 | 0 |
| 3462318 | 123444 | None | vol 6, pg no 10, 3.14.3 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A :Three Way 5 Pin Socket vol 6, pg no 10, 3.14.3 | No | 73.5 | 73.5 | 20.0 | False | None | None | False | None | False | 1470.0 | 0 |
| 3462319 | 123444 | None | vol 6, pg no 5, 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 module vol 6, pg no 5, 3.5.5 | No | 298.2 | 298.2 | 12.0 | False | None | None | False | None | False | 3578.4 | 0 |