createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720164739776
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee830.00
emd66000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-07-2024 17:30:00
tenderQueryClose11-07-2024 11:00:00
technicalBidOpen22-07-2024 11:00:00
publishedDate05-07-2024 17:48:24
publishedByPostTP_CO_TVG
publishedByUserKPE14135 - NABISAB KHUDANAVAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonJunior Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8123006169
tenderSupplierListNone
tenderSchedule
createdTs1720164739806
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT20783
titleConstruction of Proposed 3TPD MRF Primary shed for 2120 Sqft 53X40 sqft Phase 1 880 sqft 22X40 Phase 2 And Electrical Work in Tavaragera SWM site
descriptionConstruction of Proposed 3TPD MRF Primary shed for 2120 Sqft 53X40 sqft Phase 1 880 sqft 22X40 Phase 2 And Electrical Work in Tavaragera SWM site
categoryWORKS
categoryTextWorks
ecv3281799.20
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2357
locationNameDMA Town Panchayat Tavaragere
provisionalAmount3900000.0
groupOverheadTotalNone
fileNumberNO/TPTVG/SBM/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17201647400000NoneNoneOther WorksConstruction of Proposed 3TPD MRF Primary shed for 2120 Sqft 53X40 sqft Phase 1 880 sqft 22X40 Phase 2 And Electrical Work in Tavaragera SWM site3281799.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3457639123136NoneCode01KSRB 11.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0636.64FalseNoneNoneFalseNoneFalse3849.39840
3457640123136NoneCode02KSRB 22.1.2 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead & lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. Mix 148( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1 (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9236.18FalseNoneNoneFalseNoneFalse211071.22560
3457641123136NoneCode03KSRB 22.3.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3. 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.89.04FalseNoneNoneFalseNoneFalse65022.9120
3457642123136NoneCode04KSRB 22.3.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3. 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11016.011016.01.94FalseNoneNoneFalseNoneFalse21371.040
3457643123136NoneCode05KSRB 22.3.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3. 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.840.7FalseNoneNoneFalseNoneFalse292746.960
3457644123136NoneCode06KSRB 22.2.3.1 Providing and laying in Reinforced cement concrete for all Basement & surface level works return walls retaining walls sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necesary including all lead & lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.085.98FalseNoneNoneFalseNoneFalse57970.59840
3457645123136NoneCode07KSRB 2.11 Steel Fabrication Supplying fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking laping/welding joints tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)MT92140.7192140.713.7084FalseNoneNoneFalseNoneFalse341694.6089640
3457646123136NoneCode08KSRB 55.4 Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 16 (1 cement 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6717.43FalseNoneNoneFalseNoneFalse114701.07810
3457647123136NoneCode09KSRB 11.8 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead transportation to site spreading grading to required slope and compacting to meet the requirement complete as per specifications including cost of labourrollingwaterall materialsusage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum474.0474.0183.14FalseNoneNoneFalseNoneFalse86808.360
3457648123136NoneCode10KSRB 66.33 Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 14 as per IS 25722005 including cost of all materials labour scaffolding and curing usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93106.06FalseNoneNoneFalseNoneFalse134476.65580
3457649123136NoneCode11KSRB 88.3.1 Providing 15mm cement plaster of mix 14 (1 cement 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineerincharge.(Item No. 8.2.1 Page No. 41 Vol.2)Sqm303.85303.85225.61FalseNoneNoneFalseNoneFalse68551.59850
3457650123136NoneCode12Providing and fixing Structural Steel work riveted bolted or welded in built up sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. (Item No. 11.2 Page No. 77 Vol.2)Kg116.39116.398380.0FalseNoneNoneFalseNoneFalse975348.20
3457651123136NoneCode13Providing and fixing precoated galvanised iron profile sheets (size shape and pitch of corrugation as approved by Engineerincharge) 0.50 mm (0.05 Percentage) total coated thickness with zinc coating 120 g/m2 as per IS 277 in 240 mpa steel grade 57 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerincharge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38 Page No. 26 Vol.2)Sqm585.04585.04590.76FalseNoneNoneFalseNoneFalse345618.23040
3457652123136NoneCode14KSRB 88.51 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51 Page No. 50 Vol.2)Sqm103.0103.0225.61FalseNoneNoneFalseNoneFalse23237.830
3457653123136NoneCode15KSRB 88.54.1 Wall painting with premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1 Page No. 50 Vol.2)No75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3457654123136NoneCode16KSRB 88.75.2 Finishing walls with Premium Acrylic Smooth exterior paint of required shade Old work (one coats applied at 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirtdust and foreign matter cost of materials labour complete as per specifications and as per directions of Engineerincharge.(Item No. 8.75.2 Page No. 53 Vol.2)No75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3457655123136NoneCode17KSRB 1111.6.1Supplying and fixing rolling shutters of approved make made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. (Item No. 11.6.1 Page No. 76 Vol.2)Sqm2711.992711.9922.5FalseNoneNoneFalseNoneFalse61019.7750
3457656123136NoneCode18KSRB 1111.8.4Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.(Item No. 11.8.4 Page No. 77 Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3457657123136NoneCode19KSRB 1111.35.1.1Providing and fixing aluminium work for doors windows ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS 733 and IS1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i.e. at top bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing / paneling C.P. brass / stainless steel screws all complete as per architectural drawings and the directions of Engineerincharge. (Glazing paneling and dash fasteners to be paid for separately) For Fixed Portion Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials labour usage charges of machinery complete as per specifications..(Item No. 11.35.1.1 Page No. 87 Vol.2)Kg465.56465.56240.0FalseNoneNoneFalseNoneFalse111734.40
3457658123136NoneCode20Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2mm thick (P.no.2.it.no.1.1.1) (PWD CSR for Electrical Works for the Year 202324)Each71.0771.07100.0FalseNoneNoneFalseNoneFalse7107.00
3457659123136NoneCode21PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5) (PWD CSR for Electrical Works for the Year 202324)Each50.4750.473.0FalseNoneNoneFalseNoneFalse151.410
3457660123136NoneCode22Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete. 8 x 6 x 3 (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for Electrical Works for the Year 202324)Each88.5888.583.0FalseNoneNoneFalseNoneFalse265.740
3457661123136NoneCode23Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 202324)Mtr64.8964.89100.0FalseNoneNoneFalseNoneFalse6489.00
3457662123136NoneCode24Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way. (P.no.9.it.no.3.6.2) (PWD CSR for Electrical Works for the Year 202324)Each170.98170.9812.0FalseNoneNoneFalseNoneFalse2051.760
3457663123136NoneCode254mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 202324)Sqm0.420.422000.0FalseNoneNoneFalseNoneFalse840.00
3457664123136NoneCode26Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 202324)Each248.23248.233.0FalseNoneNoneFalseNoneFalse744.690
3457665123136NoneCode27Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical Works for the Year 202324)Each761.17761.172.0FalseNoneNoneFalseNoneFalse1522.340
3457666123136NoneCode28PVC Batten with LED Tubes Supplying of ......feet PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70Percentage lumen maintenance with CRI 80. Power Input 220240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4 20/22 w (p.no.43.it.no.11.3.2) (PWD CSR for Electrical Works for the Year 202324)Each710.7710.715.0FalseNoneNoneFalseNoneFalse10660.50
3457667123136NoneCode29Lamp Holder Supplying & Fixing of 70150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for Electrical Works for the Year 202324)Nos64.8964.8915.0FalseNoneNoneFalseNoneFalse973.350
3457668123136NoneCode30Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 202324)Each125.66125.6615.0FalseNoneNoneFalseNoneFalse1884.90
3457669123136NoneCode31SupplyingfixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass1AccuracyEnergyMeter. (PWD CSR for Electrical Works for the Year 202324 P.no.30.it.no.5.35)Each5876.155876.151.0FalseNoneNoneFalseNoneFalse5876.150
3457670123136NoneCode32SupplyingfixingwiringearthelectrodeforgroundingconduitsI.C.cutoutsandotherequipmentsonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmallroundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiaboltsnutswashersandchecknutsetc. the pipe shall have 16 through holes of 12 mm dia . (PWD CSR for Electrical Works for the Year 202324 P.no.54.it.no.12.56)Each3615.33615.32.0FalseNoneNoneFalseNoneFalse7230.60
3457671123136NoneCode33Fabrication Supplying Erection Testing and Commissioning of 12 ms long Polygon high mast with Single/Multiple telescopic sections having (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A57250 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A57250. The mast shall be Galvanized in single Hotdip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629 and welded as per BS 5135 Single LSeam joint The mast shall have 2 Way head frame with die cast LM6 pulleys stainless steel axle Phosphorus Bronze bearing bush pressfitted with separate guides for 2 runs of 5 mm dia stainless steel wire rope of AISI 304grade 7/19core (Factor of Safety as per TR no7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V 50Hz shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. 12 m/12.5 m Top 100 mm and Bottom 310 mm diaEach131000.0131000.01.0FalseNoneNoneFalseNoneFalse131000.00
3457672123136NoneCode34Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70Percentage CCT 5500K IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains Surge Protection Min 5KV along with Over voltage/ Overload short circuit/ misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598 LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 90012008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ LED Floodlight 150WEach12490.012490.08.0FalseNoneNoneFalseNoneFalse99920.00
3457673123136NoneCode35Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 81301984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS 6942010 3C x 4 mm2Mtr172.0172.050.0FalseNoneNoneFalseNoneFalse8600.00
3457674123136NoneCode36Earth Work Excavation Mechanical Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m as per drawing and technical specifications including setting out shoring strutting arricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour tools usage of machinery & other appurtenances required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.11.728FalseNoneNoneFalseNoneFalse185.06880
3457675123136NoneCode37Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of workCum89.2589.251.728FalseNoneNoneFalseNoneFalse154.2240
3457676123136NoneCode38Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead & lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 136 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.450.144FalseNoneNoneFalseNoneFalse905.53680
3457677123136NoneCode39RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building Irrigation works Substructure works of bridges Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necessary including all lead & lifts cost of all materials of quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8852.28852.21.38FalseNoneNoneFalseNoneFalse12216.0360
3457678123136NoneCode40TMT Steel Supplying fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking laping/welding joints tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing and technical specificationMT82961.5582961.550.012FalseNoneNoneFalseNoneFalse995.53860
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17201647460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17201647460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17201647460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17201647460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17201647460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneSimilar nature of 50 Percent work done certificate should be issued from not below the rank of an Executive Engineer or equivalentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid contractor Registration Certificate issued from competent authority in appropriate Civil contractorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid PAN Card and Valid GST Registration certificatesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLabour Certificate
NoneNoneNoneNoneContractor Address Proof with Phone NumberCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Bid Documents
NoneNoneNoneNoneAs Per KW-2 Tender DocumentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Bid Documents
NoneNoneNoneNoneFinancial Turnover Certificate obtained and certified by the Registered Valid Chartered Accountant indicating the Registration No Chartered Accountant with UDIN numberFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneUnconditional Line of credit i.e 30 Percent of amount put to tender obtained from Nationalised/Scheduled Banks in Given Pro-forma in the bid documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Financial Turnover Certificate obtained and certified by the Registered Valid Chartered Accountant indicating the Registration No Chartered Accountant with UDIN numberTrueTechnical Bid
Valid contractor Registration Certificate issued from competent authority in appropriate Civil contractorTrueTechnical Bid
Unconditional Line of credit i.e 30 Percent of amount put to tender obtained from Nationalised/Scheduled Banks in Given Pro-forma in the bid documentTrueTechnical Bid
Valid PAN Card and Valid GST Registration certificatesTrueTechnical Bid
Similar nature of 50 Percent work done certificate should be issued from not below the rank of an Executive Engineer or equivalentTrueTechnical Bid
Contractor Address Proof with Phone NumberTrueTechnical Bid
As Per KW-2 Tender DocumentTrueTechnical Bid
tenderWorkLocationList